Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para -
me ters, test conditions and
processing information only
to be used together with the
'Definitions' section in the
cat -
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays SCHRACK
1
Miniature Relay PT
n2 pole 12 A, 3 pole 10 A or 4 pole 6 A, 2, 3 or 4 CO contacts
nDC- or AC-coil
nSwitching performance up to 3000 VA
nRelay height 29 mm
nMechanical indicator, optional LED and protection diode
nManual test tab, optionally lockable.
nWhite marking tabs
Applications
Universal use in control and automation
F0191-B
Approvals
VREG.-Nr. 115719, ZE214025, L00/20059(E2)
Technical data of approved types on request
Contact data PT2 PT3 PT5
Contact configuration 2 CO 3 CO 4 CO
Contact set single contact
Type of interruption micro disconnection
Rated voltage / max. switching voltage AC 240 / 400 VAC 240 / 400 VAC 240/240 VAC
Rated current 12 A 10 A 6 A
Maximum breaking capacity AC 3000 VA 2500 VA 1500 VA
Limiting making capacity, max 20 ms 24 A 20 A 12 A
Contact material AgNi90/10, AgNi90/10 gold plated
Minimum contact load 12V/10mA, 20mV/1mA gold plated
Rated frequency of operation with / without load 6/600 min-1
Operate time typ 15 ms
Release time DC coil without / with protection diode typ 10 / 18 ms
Bounce time DC coil NO / NC contact typ 6 / 8 ms
Contact ratings
Type Contact Load Ambient Cycles
temp. [°C]
IEC 61810
PT 2 DC/AC-coil CO 12 A, 250 VAC, cosϕ=1 70°C 70x103
PT 2 DC/AC-coil NO of CO 9 A, 250 VAC, cosϕ=1 80°C 150x103
PT 2 DC/AC-coil NO of CO 4 A, 250 VAC, cosϕ=1 80°C 300x103
PT 3 DC/AC-coil CO 10 A, 250 VAC, cosϕ=1 70°C 100x103
PT 5 DC/AC-coil CO 6 A, 250 VAC, cosϕ=1 70°C 100x103
UL 508
PT 2 CO 12 A, 250 VAC, general purpose 70°C 6.000
PT 2 CO 12 A, 250 VAC, resistive 70°C 100x103
PT 2 NO of CO 12 A, 250 VAC, resistive 70°C 100x103
PT 2 NC of CO 12 A, 250 VAC, resistive 70°C 100x103
PT 3 CO 10 A, 250 VAC, general purpose 70°C 6.000
PT 3 CO 10 A, 250 VAC, resistive 70°C 100x103
PT 3 NO of CO 10 A, 250 VAC, resistive 70°C 100x103
PT 3 NC of CO 10 A, 250 VAC, resistive 70°C 100x103
PT 5 CO 6 A, 250 VAC, general purpose 70°C 6.000
PT 5 CO 6 A, 250 VAC, resistive 70°C 100x103
PT 5 NO of CO 6 A, 250 VAC, resistive 70°C 100x103
PT 5 NC of CO 6 A, 250 VAC, resistive 70°C 100x103
EN60947-4-1
PT 2 NO of CO 400 VAC, 3,75 A, AC3, opposite polarity 70°C
PT 2 NO of CO
230 VAC, 1,7A, AC5b (400W lamp load), opposite polarity
70°C
PT 3 NO of CO 250 VAC, 2 A, AC3, opposite polarity 70°C
PT 3 NO of CO
230 VAC, 1,7A, AC5b (400W lamp load), opposite polarity
70°C
PT 5 NO of CO 250 VAC, 3 A, AC3, same polarity 70°C
PT 5 NO of CO
230 VAC, 1,7A, AC5b (400W lamp load), same polarity
70°C