Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
SIP 7 (VDC) (VDC) (mA) (%) Load(1)
RP-xx3.3S* 5, 9, 12, 15, 24 3.3 303 70 2200µF
RP-xx05S* 5, 9, 12, 15, 24 5 200 70-72 1000µF
RP-xx09S* 5, 9, 12, 15, 24 9 111 75 1000µF
RP-xx12S* 5, 9, 12, 15, 24 12 84 75-78 470µF
RP-xx15S* 5, 9, 12, 15, 24 15 66 80 470µF
RP-xx24S* 5, 9, 12, 15, 24 24 42 80 220µF
RP-xx3.3D* 5, 9, 12, 15, 24 ±3.3 ±152 70 ±1000µF
RP-xx05D* 5, 9, 12, 15, 24 ±5 ±100 74-76 ±470µF
RP-xx09D* 5, 9, 12, 15, 24 ±9 ±56 75 ±470µF
RP-xx12D* 5, 9, 12, 15, 24 ±12 ±42 79-82 ±220µF
RP-xx15D* 5, 9, 12, 15, 24 ±15 ±33 80-82 ±220µF
RP-xx24D* 5, 9, 12, 15, 24 ±24 ±21 80 ±100µF
RP-xx1509D 5, 12, 24 +15/-9 ±42 70-85 ±220µF
xx = Input Voltage. Other input and output voltage combinations available on request
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RP-0505S/P, RP-0505D/P
* add Suffix “/X2” for single output with alternative pinning e.g. RP-0505S/X2, RP-0505S/P/X2
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types, RP-xx1509D 10% max.
Output Ripple and Noise (20MHz limited) 100mVp-p max.
Operating Frequency 50kHz min. / 100kHz typ. / 120kHz max.
RP-xx1509D 50kHz min / 94kHz typ.
Efficiency at Full Load 70% min. / 80% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 5200VDC
(rated for 1 minute**) 2600VAC / 60Hz
Isolation Capacitance 4pF min. / 10pF max.
Isolation Resistance 20 GΩmin.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection, without derating) -40°C to +85°C (see Graph)
continued on next page
1 Watt
SIP 7 Single &
Dual Output
Derating-Graph
(Ambient Temperature)
●Pot-Core Transformer - separated windings
●High 5.2kVDC Isolation in compact size
●Optional Continuous Short Circuit Protected
●Pin Compatible with RH and RK Series
●Approved for Medical and IGBT Applications
●UL and EN Certified
●Efficiency to 82 %
Features
Unregulated
Converters
Description The RP series has very high isolation of 5.2 kVDC in a compact size. The converters are
EN-60601-1 certified, making them suitable for medical as well as IGBT driver applications.
The /X2 version has rearranged pins to permit an input output seperation of more than 9mm.
RP
RP
RoHS
2011/65/EU
6/6 E-358085
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
REV: 2/2015 www.recom-power.comE-66