www.clare.com
2R01
LBA710
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics: Form-A (Normally Open)
Load Current
Continuous IF=2mA IL--1
A
Peak IF=2mA, t < 10ms ILPK --5
On-Resistance IF=2mA, IL=1A RON - 0.21 0.6 Ω
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.7 5 ms
Turn-Off toff - 0.09 5
Off-State Leakage Current IF=0mA, VL=60V ILEAK --1μA
Output Capacitance IF=0mA, VL=50V, f=1MHz COUT -44-pF
Output Characteristics: Form-B (Normally Closed)
Load Current
Continuous IF=0mA IL--1
A
Peak IF=0mA, t < 10ms ILPK --5
On-Resistance IF=0mA, IL=1A RON - 0.39 0.6 Ω
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.63 5 ms
Turn-Off toff - 1.5 5
Off-State Leakage Current IF=2mA, VL=60V ILEAK --1μA
Output Capacitance IF=2mA, VL=50V, f=1MHz COUT - 125 - pF
Input Characteristics: Form-A and Form-B
Input Control Current IL=1A IF--2mA
Input Dropout Current - IF0.1 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10μA
Common Characteristics: Form-A and Form-B
Capacitance, Input to Output - CI/O -3-pF
*NOTE: If both poles operate simultaneously, then load current must be derated so as not to exceed the package total power dissipation value.
Parameter Ratings Units
Blocking Voltage 60 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
ESD Rating, Human Body Model 8 kV
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW/˚C
2 Derate linearly 6.67 mW/˚C
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC