MOS FET Relays G3VM-402J Analog-Switching MOS FET Relays with 400-V Load Voltage * Two channels and an 8-pin SOP package included in a 400-V load voltage series. * Continuous load current of 120 mA. * Dielectric strength of 1,500 Vrms between I/O. * RoHS Compliant. Application Examples Note: The actual product is marked differently from the image shown here. * Broadband systems * Measurement devices and Data loggers * Amusement machines List of Models Contact form DPST-NO Terminals Surface-mounting terminals Load voltage (peak value) 400 VAC Model Number per stick Number per tape G3VM-402J 50 --- G3VM-402J(TR) --- 2,500 Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-402J 4.40.25 2.1 max. 9.40.25 0.15 Note: The actual product is marked differently from the image shown here. 0.60.3 0.10.1 0.40.1 2.54 7.00.4 Weight: 0.2 g Terminal Arrangement/Internal Connections (Top View) G3VM-402J 8 7 6 5 1 2 3 4 Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-402J 6 to 6.3 1.2 0.8 2.54 2.54 MOS FET Relays G3VM-402J 223 Absolute Maximum Ratings (Ta = 25C) Item Input Symbol Rating Unit Measurement conditions LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps LED forward current reduction rate IF/C -0.5 mA/C Ta 25C LED reverse voltage VR 5 V Tj 125 C VOFF 400 V Continuous load current IO 120 mA ON current reduction rate ION/C -1.2 Connection temperature Output Load voltage (AC peak/DC) Note: mA/C Ta 25C Dielectric strength between input and VI-O output (See note 1.) 1,500 Vrms AC for 1 min Operating temperature Ta -40 to +85 C With no icing or condensation Storage temperature Tstg -55 to +125 C With no icing or condensation Soldering temperature (10 s) --- 260 C 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. 10 s Electrical Characteristics (Ta = 25C) Item Input Minimum Symbol Typical LED forward voltage VF 1.0 1.15 Reverse current IR --- Capacity between terminals CT --- Trigger LED forward current Maximum Measurement conditions Unit 1.3 V IF = 10 mA --- 10 A VR = 5 V 30 --- pF V = 0, f = 1 MHz IFT --- 1 3 mA IO = 120 mA RON --- 17 35 IF = 5 mA, IO = 120 mA Current leakage when the relay is open ILEAK --- 0.003 1.0 A VOFF = 400 V Capacity between terminals Output Maximum resistance with output ON COFF --- 70 --- pF V = 0, f = 1MHz CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance RI-O 1,000 --- --- M VI-O = 500 VDC, RoH 60% Turn-ON time tON --- 0.3 1 ms Turn-OFF time tOFF --- 0.1 1 ms IF = 10 mA, RL = 200 , VDD = 20 V (See note 2.) Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum VDD --- --- 320 Operating LED forward current IF Unit V 5 7.5 25 mA Continuous load current (AC peak/DC) IO --- --- 120 mA Operating temperature - 20 --- 65 C 224 Ta MOS FET Relays G3VM-402J 2. Turn-ON and Turn-OFF Times IF (3) 1 8(6) (4) 2 7(5) RL IF Capacity between I/O terminals Load voltage (AC peak/DC) Note: VOUT 10% t ON 90% t OFF VDD VOUT Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature 100 80 60 40 20 0 20 40 60 80 100 280 240 200 160 120 80 0 -20 120 0 Continuous load current vs. On-state voltage 20 On-state resistance RON () 60 80 100 100 0 -100 0 1 2 40 30 20 0 20 40 60 80 100 100 tOFF Turn ON, Turn OFF time tON, tOFF (S) 300 5 10 LED forward current IF (mA) 30 50 100 VDD = 20 V, RL = 200 IF = 5 mA 800 tON 600 400 0 20 1.8 IO = 120 mA t<1s 4 3 2 1 0 -40 -20 0 40 20 40 60 80 100 60 80 1000 VOFF = 400 V 500 300 100 50 30 10 5 tOFF 200 -20 1.6 I LEAK - Ta 1000 0 -40 1.4 Current leakage vs. Ambient temperature 3 50 30 1.2 5 tON, tOFF - Ta 500 3 1 Ambient temperature Ta () Turn ON, Turn OFF time vs. Ambient temperature VDD = 20 V, RL = 200 1 0.8 Ambient temperature Ta () Ta = 25C 1000 1 0.5 IFT - Ta IO = 120 mA IF = 5 mA tON, tOFF - IF tON 3 Trigger LED forward current vs. Ambient temperature 50 0 -20 3 Turn ON, Turn OFF time vs. LED forward current 2000 5 LED forward voltage VF (V) 10 -1 10 0.1 0.6 120 Current leakage ILEAK (nA) Continuous load current IO (mA) Ta = 25C IF = 5 mA -2 30 RON - Ta 60 On-state voltage VON (V) Turn ON, Turn OFF time tON, tOFF (S) 40 On-state resistance vs. Ambient temperature IO - VON -200 -3 Ta = 25C 50 Ambient temperature Ta Ambient temperature Ta () 200 100 0.3 40 Trigger LED forward current I F T (mA) 0 -20 IF - VF LED forward current I F (mA) IO - Ta Continuous load current I O (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 100 1 -20 Ambient temperature Ta ( MOS FET Relays 0 20 40 60 80 100 Ambient temperature Ta () G3VM-402J 225 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X302-E-1 MOS FET Relays 12/10 Specifications subject to change without notice G3VM-402J Printed in USA