PMF Panel Mount Power
Supply
24V 200W 1
Phase
/ PMF-24V200WC
□□
All parameters are specified at 25° C am bient unless otherwis e i ndicated.
www.DeltaPSU.com (November 2013, Rev. 00)
Environment
Surrounding Air Temperature Operating -10°C to +70°C (Cold start at -20°C)
Storage -25°C to +85°C
Power De-rating > 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 1.33% / 1V
Operating Humidity 10-95% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters
Shock Test (Non-Operating) IEC 60068-2-27, Half Sine: 50G for a durat ion of 11ms,
3 shocks for each 3 directions
Vibration (Non-Operating) IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms);
20 min per axis for all X, Y, Z direction
Pollution Degree 2
Protections
Overvoltage 27.6-32.4V, Latch Mode
(AC power is recycled)
Overload / O vercurrent 105-150%, Hicc-up M ode, Non-Latching
(Auto-Recovery)
Over Temperature Hicc-up Mode, N on-Latching
(Auto-Recovery when the faul t is removed)
Short Circuit Hicc-up Mode, Non-Latching
(Auto-Recovery when the faul t is removed)
Protection Against Shock Class I with PE* c onnection
*PE: Primary Earth
Reliability Data
MTBF > 700,000 hrs. as per Telcordi a SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C
Expected Cap Li fe Time 10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety Standards / Directives
Electrical S afety TUV Bauart to EN 60950-1, UL/cUL recognized to UL
60950-1 and CS A C22.2 No. 60950-1, CB schem e to
IEC 60950-1, CCC t o GB4943
CE In conformance wit h E MC Directive 2004/10 8/EC and
Low Voltage Directive 2006/95/EC
Material and P arts RoHS Directive 2011/65/EU Compliant
Galvanic Is olation Input to Output 3.0KVac
Input to Ground 2.0KVac
Output to Gr ound 0.5KVac