MURS340S, MURS360S www.vishay.com Vishay General Semiconductor Surface Mount Ultrafast Plastic Rectifier FEATURES * Glass passivated pellet chip junction * Ideal for automated placement * Ultrafast reverse recovery time * Low switching losses, high efficiency * Meets MSL level 1, per LF maximum peak of 260 C J-STD-020, * AEC-Q101 qualified available - Automotive ordering code: base P/NHE3 * Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 SMB (DO-214AA) TYPICAL APPLICATIONS For use in high frequency rectification and freewheeling application in switching mode converters and inverters for consumer, computer and telecommunication. PRIMARY CHARACTERISTICS IF(AV) 3.0 A VRRM 400 V, 600 V IFSM 35 A trr 50 ns VF at IF = 3.0 A 1.20 V TJ max. 175 C Package SMB (DO-214AA) Circuit configuration Single MECHANICAL DATA Case: SMB (DO-214AA) Molding compound meets UL 94 V-0 flammability rating Base P/N-E3 - RoHS-compliant, commercial grade Base P/NHE3_X - RoHS-compliant, and AEC-Q101 qualified ("_X" denotes revision code e.g. A, B,.....) Terminals: matte tin plated leads, solderable per J-STD-002 and JESD 22-B102 E3 and HE3 suffix meet JESD 201 class 2 whisker test Polarity: color band denotes cathode end MAXIMUM RATINGS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL Device marking codes Maximum repetitive peak reverse voltage Maximum average forward rectified current VRRM MURS340S MURS360S 3GS 3JS 400 600 UNIT V TM = 130 C IF(AV) (1) 3.0 TA = 25 C IF(AV) (2) 1.5 IFSM 35 A TJ, TSTG -65 to +175 C Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load Operating junction and storage temperature range A Notes (1) Units mounted on PCB with 8 mm x 8 mm, 1 oz. copper pad areas (fig. 1) (2) Free air, mounted on recommended copper pad area (fig. 2) Revision: 22-Mar-18 Document Number: 89110 1 For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 MURS340S, MURS360S www.vishay.com Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER TEST CONDITIONS Maximum instantaneous forward voltage IF = 3.0 A Maximum instantaneous reverse current Rated VR SYMBOL TJ = 25 C MURS340S VF (1) TJ = 150 C TJ = 25 C UNIT V 1.20 5.0 IR (2) TJ = 150 C MURS360S 1.45 A 150 Maximum reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 50 ns Maximum reverse recovery time IF = 1.0 A, dI/dt = 50 A/s, VR = 30 V, Irr = 10 % IRM trr 75 ns Notes (1) Pulse test: 300 s pulse width, 1 % duty cycle (2) Pulse test: pulse width 40 ms THERMAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL Typical thermal resistance MURS340S MURS360S RJM (1) 12 RJA (2) 120 UNIT C/W Notes (1) Units mounted on PCB with 8 mm x 8 mm, 1 oz. copper pad areas. Thermal resistance R JM - junction to mount (2) Free air, mounted on recommended copper pad area. Thermal resistance R JA - junction to ambient ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE MURS360S-E3/52T 0.093 52T 750 7" diameter plastic tape and reel MURS360S-E3/5BT 0.093 5BT 3200 13" diameter plastic tape and reel 0.093 H 750 7" diameter plastic tape and reel 0.093 I 3200 13" diameter plastic tape and reel MURS360SHE3_A/H (1) MURS360SHE3_A/I (1) Note (1) AEC-Q101 qualified Revision: 22-Mar-18 Document Number: 89110 2 For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 MURS340S, MURS360S www.vishay.com Vishay General Semiconductor RATINGS AND CHARACTERISTICS CURVES (TA = 25 C unless otherwise noted) 100 Instantaneous Forward Current (A) Average Forward Rectified Current (A) 3.0 2.0 1.0 Units Mounted on P.C.B. with 8 mm x 8 mm, 1 oz. Copper Pad Areas. TM Measured at Mount of Terminal 0 25 50 75 100 125 150 TA = 150 C 1 TA = 100 C TA = 125 C 0.1 TA = 25 C 175 0 0.4 0.8 1.2 1.6 2.0 TM - Mount Temperature (C) Instantaneous Forward Voltage (V) Fig. 1 - Forward Current Derating Curve Fig. 4 - Typical Instantaneous Forward Characteristics 1000 Instantaneous Reverse Current (A) 1.6 Average Forward Current (A) TA = 175 C 0.01 0 1.4 1.2 1.0 0.8 0.6 0.4 Mounted on P.C.B. with Recommended Copper Pad Areas 0.2 TA = 175 C 100 TA = 150 C TA = 125 C 10 TA = 100 C 1 TA = 25 C 0.1 0.01 0 0 25 50 75 100 125 150 175 10 20 30 40 50 60 70 80 90 TA - Ambient Temperature (C) Percent of Rated Peak Reverse Voltage (%) Fig. 2 - Forward Current Derating Curve Fig. 5 - Typical Reverse Characteristics 4.4 100 100 TJ = 25 C f = 1.0 MHz Vsig = 50 mVp-p D = 0.8 4.0 D = 0.3 D = 0.5 3.6 Junction Capacitance (pF) Average Power Loss (W) 10 D = 0.2 3.2 2.8 D = 0.1 2.4 D = 1.0 2.0 1.6 T 1.2 0.8 D = tp/T 0.4 tp 0 0 0.5 1.0 1.5 2.0 2.5 10 3.0 3.5 1 0.1 1 10 Average Forward Current (A) Reverse Voltage (V) Fig. 3 - Forward Power Loss Characteristics Fig. 6 - Typical Junction Capacitance 100 Revision: 22-Mar-18 Document Number: 89110 3 For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 MURS340S, MURS360S www.vishay.com Vishay General Semiconductor PACKAGE OUTLINE DIMENSIONS in inches (millimeters) SMB (DO-214AA) Cathode Band Mounting Pad Layout 0.085 (2.159) MAX. 0.155 (3.94) 0.130 (3.30) 0.086 (2.20) 0.077 (1.95) 0.086 (2.18) MIN. 0.180 (4.57) 0.160 (4.06) 0.060 (1.52) MIN. 0.012 (0.305) 0.006 (0.152) 0.220 (5.59) REF. 0.096 (2.44) 0.084 (2.13) 0.060 (1.52) 0.030 (0.76) 0.008 (0.2) 0 (0) 0.220 (5.59) 0.205 (5.21) Revision: 22-Mar-18 Document Number: 89110 4 For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. (c) 2019 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 01-Jan-2019 1 Document Number: 91000