6
E0C6003
●Analog Circuit Characteristics and Current Consumption
E0C6003 (Crystal Oscillation)
Unit
V
V
V
µA
µA
µA
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=32.768kHz, Ta=25°C, CG=25pF, VS2 is internal voltage, C1=C2=0.1µF)
Max.
1/3·VSS
×0.9
2/3·VSS
×0.9
2.5
5.0
20
Typ.
1/3·VSS
2/3·VSS
VSS
1.0
2.0
15
Min.
1/3·VSS
- 0.1
2/3·VSS
- 0.1
Characteristic
LCD drive voltage
Current consumption
Symbol
VL1
VL2
VL3
IHLT
IEXE1
IEXE2
Condition
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL1
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL2
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL3
During HALT with LCD OFF
During operation with LCD OFF
During operation with power divider ON No panel load
E0C60L03 (Crystal Oscillation)
Unit
V
V
V
µA
µA
µA
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC=32.768kHz, Ta=25°C, CG=25pF, VS2 is internal voltage, C1=C2=0.1µF)
Max.
1/3·VS2
×0.9
2/3·VS2
×0.9
VS2
×0.9
2.5
5.0
20
Typ.
1/3·VS2
2/3·VS2
VS2
1.0
2.0
15
Min.
1/3·VS2
- 0.1
2/3·VS2
- 0.1
VS2
- 0.1
Characteristic
LCD drive voltage
Current consumption
Symbol
VL1
VL2
VL3
IHLT
IEXE1
IEXE2
Condition
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL1
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL2
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL3
During HALT with LCD OFF
During operation with LCD OFF
During operation with power divider ON No panel load
E0C6003 (CR Oscillation)
Unit
V
V
V
µA
µA
µA
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=65kHz, Ta=25°C, RCR=470kΩ, VS2 is internal voltage, C1=C2=0.1µF)
Max.
1/3·VSS
×0.9
2/3·VSS
×0.9
15
20
30
Typ.
1/3·VSS
2/3·VSS
VSS
8
15
25
Min.
1/3·VSS
- 0.1
2/3·VSS
- 0.1
Characteristic
LCD drive voltage
Current consumption
Symbol
VL1
VL2
VL3
IHLT
IEXE1
IEXE2
Condition
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL1
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL2
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL3
During HALT with LCD OFF
During operation with LCD OFF
During operation with power divider ON No panel load
E0C60L03 (CR Oscillation)
Unit
V
V
V
µA
µA
µA
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC=65kHz, Ta=25°C, RCR=470kΩ, VS2 is internal voltage, C1=C2=0.1µF)
Max.
1/3·VS2
×0.9
2/3·VS2
×0.9
VS2
×0.9
15
20
30
Typ.
1/3·VS2
2/3·VS2
VS2
8
15
25
Min.
1/3·VS2
- 0.1
2/3·VS2
- 0.1
VS2
- 0.1
Characteristic
LCD drive voltage
Current consumption
Symbol
VL1
VL2
VL3
IHLT
IEXE1
IEXE2
Condition
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL1
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL2
Connect 1 MΩ load resistor between VDD and segment
driver (SEG0–SEG14) when segment driver's level is VL3
During HALT with LCD OFF
During operation with LCD OFF
During operation with power divider ON No panel load