1
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Slim I/O Relay
G2RV-SR/G3RV-SR
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay
Realized about 25% lower profile than conventional
products, contributing to further miniaturization of the
control panel.
Push-In Plus technology are used to save wiring work in
comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with
traditional screw terminals.)
No screw loosening means maintenance-free application,
realizing high reliability
‘Hand-free’ structure that holds an inserted flat-blade
screwdriver to achieve easier wiring work for stranded
wires.
Screw terminal is also stocked to meet the screw type
needs.
Mounted relay or solid-state relay has a plug-in terminal
that is difficult to bend at the time of exchange.
*According to OMRON actual measurement data from November 2015.
Slim I/O Relay Types
G2RV-SR series mounted relay: electromagnetic relay ......from page 2
G3RV-SR series mounted relay: solid state relay ................from page 10
Common matter
Common precautions................................................................from page 20
Common accessories (order separately).................................from page 24
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 20.
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
2
Slim I/O Relay
G2RV-SR
Global standard size, low profile slim
I/O relay with width 6.2 mm
Realized about 25% lower profile than conventional
products, contributing to further miniaturization of the
control panel.
Realized opening and closing ability with one pole 6 A slim
shape.
Micro load products for one pole 50 mA using Au-plated
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of
the contact with the naked eye is possible, and easy to
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type
needs.
Mounted relay uses plug-in terminals that are difficult to
bend when exchanging.
Features
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 20.
Transparent case
Relay contact
Release lever
Plug-in terminal
90 mm
80 mm
Peace of mind as the
terminal does not bend
when replacing
Easy confirmation
of the situation
Relay easily
fixed/removed
PAT
Ter minal x 5
• Push-in plus
Screw
Mechanical
indicator
Release lever Operation
display LED
(Socket section)
• Operation
verification
which is linked
to the contact
Standard model/Micro load With latching lever
(Test switch)
Latching lever
(Test switch)
• Circuit check operation
Confirmation, reducing the inspection effort
Latching lever
(Test switch)
Protective cover
(Released state)
Push-in plus technology
Short bar insertion holes
Ter minal (insertion) hole
Release hole
Protective cover
(Locked condition)
"Foreign matter intrusion prevention structure"
"Malfunction prevention stopper"
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
3
Model Number Structure
Model Number Legend
Ordering Information
Note: Solid wire cannnot be used for Push-in plus technology, make sure to use stranded wire or stranded wire with ferrules.
Terminal
(Wire connection) Classification Latching lever
(Test switch) Rated input voltage (V) Model
Push-in plus
technology
Standard
No
DC 12 G2RV-SR500 DC12
24 G2RV-SR500 DC24
AC/DC 24 G2RV-SR500 AC/DC24
48 G2RV-SR500 AC/DC48
AC
100 G2RV-SR500 AC100
110 G2RV-SR500 AC110
200 G2RV-SR500 AC200
230 G2RV-SR500 AC230
Yes DC 24 G2RV-SR501 DC24
AC/DC 24 G2RV-SR501 AC/DC24
Microloads No
DC 12 G2RV-SR500-AP DC12
24 G2RV-SR500-AP DC24
AC/DC 24 G2RV-SR500-AP AC/DC24
48 G2RV-SR500-AP AC/DC48
AC
100 G2RV-SR500-AP AC100
110 G2RV-SR500-AP AC110
200 G2RV-SR500-AP AC200
230 G2RV-SR500-AP AC230
Screw technology
Standard
No
DC 12 G2RV-SR700 DC12
24 G2RV-SR700 DC24
AC/DC 24 G2RV-SR700 AC/DC24
48 G2RV-SR700 AC/DC48
AC
100 G2RV-SR700 AC100
110 G2RV-SR700 AC110
200 G2RV-SR700 AC200
230 G2RV-SR700 AC230
Yes DC 24 G2RV-SR701 DC24
AC/DC 24 G2RV-SR701 AC/DC24
Microloads No
DC 12 G2RV-SR700-AP DC12
24 G2RV-SR700-AP DC24
AC/DC 24 G2RV-SR700-AP AC/DC24
48 G2RV-SR700-AP AC/DC48
AC
100 G2RV-SR700-AP AC100
110 G2RV-SR700-AP AC110
200 G2RV-SR700-AP AC200
230 G2RV-SR700-AP AC230
G2RV-SR @@ @ - @ @
(1) (2) (3) (5) (6)(4)
(1) Basic model name
G2RV: Slim I/O Relay
(2) Sub type
SR: Slim relay + integrated low profile socket
(3) Terminal (wire connection)
50: Push-in plus technology
70: Screw technology
(4) Latching lever (test switch)
0: Without latching lever
1: With latching lever
(5) Contact structure
Blank: Standard
AP: Microloads
(6) Rated input voltage
12, 24 VDC
24, 48 VAC/VC
100, 110, 200, 230 VAC
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
4
Relay for Maintenance
Model Number Legend
List of Models
(1) No. of poles
1: 1 pole
(2) Terminal
S: plug-in
(3) Latching lever (Test switch)
Blank: Without latching lever
I: With latching lever
(4) Contact material
Blank: Ag alloy
AP: Ag alloy + Au plating
(5) Types of relay for exchange
G: G2RV-SR series equipped
Relay
(6) Rated coil voltage
Number: 11, 21, 48 VDC
(1) (2) (3) (5) (6)(4)
G2RV-1 - S @ - @ - G @
G2RV-1-SI-G G2RV-1-S(-AP)-G
Type Latching
Lever
(Test switch)
Rated coil
voltage (V) Model Applicable model
Standard
No DC
11 G2RV-1-S-G DC11 G2RV-SR700/500 DC12V
21 G2RV-1-S-G DC21 G2RV-SR700/500 DC24V
G2RV-SR700/500 AC/DC24V
48 G2RV-1-S-G DC48
G2RV-SR700/500 AC/DC48V
G2RV-SR700/500 AC100V
G2RV-SR700/500 AC110V
G2RV-SR700/500 AC200V
G2RV-SR700/500 AC230V
Yes DC 21 G2RV-1-SI-G DC21 G2RV-SR701/501 DC24V
G2RV-SR701/501 AC/DC24V
Microload
No DC
11 G2RV-1-S-AP-G DC11 G2RV-SR700/500-AP DC12V
21 G2RV-1-S-AP-G DC21 G2RV-SR700/500-AP DC24V
G2RV-SR700/500-AP AC/DC24V
48 G2RV-1-S-AP-G DC48
G2RV-SR700/500-AP AC/DC48V
G2RV-SR700/500-AP AC100V
G2RV-SR700/500-AP AC110V
G2RV-SR700/500-AP AC200V
G2RV-SR700/500-AP AC230V
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
5
Specifications
Ratings
Coil ratings
Note: The operating characteristics are measured at ambient temperature of 23°C.
*Operating voltage will be, for mounting in the upside down direction, 85% max.
Contact ratings
*1. P level: 60=0.1×10-6/times
This value is the value in switching frequency 120 operations/min.
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.
Characteristics
Note: Above values are initial values.
*Value is at ambient temperature of 23°C.
Rated input
voltage
Rated current Must operate
voltage Must release
voltage Power consumption Maximum
allowable voltage
AC DC Percentage of the rated voltage AC (VA) DC (mW) Percentage of the
rated voltage
50 Hz 60 Hz
12 VDC 27.9 mA
80% max.* 10% min.
Approx. 300 mW
110%
24 VDC 13.5 mA
Approx. 300 mW
24 VAC/VDC 12.5 mA 12.6 mA 12.6 mA
Approx. 0.5 VA
Approx. 300 mW
48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA
Approx. 0.4 VA
Approx. 250 mW
100 VAC 5.9 mA 6.0 mA
Approx. 0.8 VA
110 VAC 5.9 mA 5.9 mA
Approx. 0.8 VA
200 VAC 3.6 mA 4.3 mA
Approx. 1.7 VA
230 VAC 3.8 mA 4.5 mA
Approx. 1.7 VA
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP) *2
Contact configuration SPDT
Load Resistive load
(cos=1)
Inductive load
(cos=0.4, L/R=7ms)
Resistive load
(cos=1)
Rated load 6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated carry current 6 A 50 mA
Maximum switching voltage 440 VAC, 125 VDC 30 VAC, 36 VDC
Maximum switching current 6 A 50 mA
Maximum switching power 1,500 VA
180 W
500 VA
60 W
Failure rate P value
(reference value) *1 10 mA at 5 VDC 1 mA at 100 mVDC
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP)
Contact resistance * 100 m max.
Operate (Set) time * 20 ms max.
Release time * AC, AC/DC: 40 ms max.
DC: 20 ms max.
Maximum operating frequency Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Insulation resistance 1,000 M min. (at 500 VDC)
Dielectric strength Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance Destruction: 1,000 m/s2
Malfunction: Energized 200m/s2, Non-energized 100m/s2
Endurance *
Mechanical 5,000,000 operations min.
Electrical NO contact: 70,000 operations min.
NC contact: 50,000 operations min. 5,000,000 operations min.
Ambient operating temperature Operating: –40 to +55°C (with no icing or condensation)
Ambient operating humidity Operating: 5 to 85% RH
Weight Approx. 30 g
Contact material Ag alloy Ag alloy + Au plating
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
6
Approved standards
UL508 (file No.E41643)
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).
TÜV (EN 61810-1)
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).
Engineering Data
Endurance curve (N.O. side) Switching capacity of DC resistive load
Model No. of poles Operation coil ratings Contact ratings Operations
G2RV-SR series
SPDT 12 to 48 VDC
24 to 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive
load)*
6,000
Model No. of poles Operation coil ratings Contact ratings Operations
G2RV-SR series
SPDT
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive
load)*
50,000
50,000
6,000
12 mm 12 mm 12 mm
10
100
1000
024
Opening and closing current (A)
6
250 VAC resistive load
30 VDC resistive load
30 VDC
resistive load
250 VAC resistive load
Number of operations (x 103 operations)
0.1
1.0
10.0
20 60 100 140 180 220
DC switching voltage (V)
DC breaking current (A)
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
7
Dimensions (unit: mm)
Slim I/O Relay + socket
Push-in plus technology
65.89
51.72
35.25
18.78
35.25
74.5
18.78
35.3
78.77
(5.05)
(5.05)
59.71
3.4
78 max.
90 max.
6.2 max.
A1
A2
12
14
11
Input circuit
Input circuit
11
14
12
A2
A1
G2RV
G2RV
* : Diode bridge
Other voltage
: Light emitting diode
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
24 VDC
12
A2
14
11
A1
Input circuit
G2RV
12 VDC
Models without latching lever (without test switch)
G2RV-SR500
G2RV-SR500-AP
65.89
51.72
35.25
18.78
35.25
77.5
18.78
35.3
78.77
(5.05)
(5.05)
59.71
3.4
81 max.
90 max.
6.2 max.
12
A2
14
11
A1
A1
A2
12
14
11
11
14
12
A2
A1
G2RV
G2RV
G2RV
Input circuit
Input circuit
Input circuit
* : Diode bridge
Other voltage
: Light emitting diode
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
24 VDC
Models with latching lever (with test switch)
G2RV-SR501
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
8
Screw terminal
65.89
51.65
35.18
18.71
18.71
35.18
74.5
(5.05)
(5.05)
35.3
78.77
56.2
3.4
78 max.
6.2 max.
90 max.
11
14
12
A2
A1
A1
11
14
A2
12
Input circuit
G2RV
Input circuit
G2RV
* : Diode bridge
Other voltage
: Light emitting diode
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
A1
A2
12
14
11
Input circuit
G2RV
24 VDC
Models without latching lever (without test switch)
G2RV-SR700
G2RV-SR700-AP
65.89
51.65
35.18
18.71
18.71
35.18
77.5
(5.05)
(5.05)
35.3
78.77
56.2
3.4
81 max.
6.2 max.
90 max.
A1
A2
12
14
11
11
14
12
A2
A1
A1
11
14
A2
12
G2RV
G2RV
G2RV
Input circuit
Input circuit
Input circuit
* : Diode bridge
Other voltage
: Light emitting diode
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
24 VDC
Models with latching lever (with test switch)
G2RV-SR701
G2RV-SR
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
9
Relay for maintenance
A2
A1
12
11
14
30.5 max.
3.5
0.5 2.4
1.8
5.2 max.
5.04 5.04
3
22
33 max.
16.2
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
(Input circuit)
Models without latching lever
G2RV-1-S-G
G2RV-1-S-AP-G
Models with latching lever (test switch)
G2RV-1-SI-G
A2
A1
12
11
14
30.5 max.
5.2 max.
1.80.5
2.4
5.04
5.04
3
22
36 max.
16.2
3.5
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
(Input circuit)
10
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Slim I/O Solid State Relay
G3RV-SR
Global standard size, low profile type
slim I/O solid state relay with width
6.2 mm.
Realized about 25% lower profile than conventional products,
contributing to further miniaturization of the control panel.
Optimal slim, high frequency, high-speed opening and closing
SSR (solid state relay).
Realized a slim shape with a switching capacity up to
3 A (DC), and 2 A (AC).
Because MOSFET is used for the outlet element for the DC
load, opening and closing load of 100 A to 3 A is possible.
Check operating status at a glance at the operating display
LED.
Mounted I/O SSR (solid-state relay) uses plug-in terminals that
are difficult to bend when exchanging.
Features
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 20.
Ter minal x 5
• Push-in
Screw
Release lever Operation display LED
(Socket section)
Operation
display LED
(SSR section)
Push-in plus technology
Short bar insertion holes
Ter minal (insertion) hole
Release hole
Release lever
Plug-in terminal
90 mm
80 mm
Relay easily
fixed/removed
Peace of mind as the terminal
does not bend when replacing
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
G3RV-SR
11
Model Number Structure
Model Number Legend
(1) Basic model name
G3RV: Slim I/O Solid State Relay
(2) Sub type
SR: Slim solid relay + integrated low profile socket
(3) Terminal (wire connection)
500: Push-in plus technology
700: Screw technology
(4) Output voltage specification
A : AC output (triac) zero cross function available
AL : AC output (triac) zero cross function not available
D : DC output (MOS FET)
(5) Rated voltage input
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
G3RV-SR @ @ @ - @ @
(1) (2) (3) (4) (5)
G3RV-SR
12
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Ordering Information
Note: Solid wire cannnot be used for Push-In Plus terminal type, make sure to use stranded wire or stranded wire with ferrules.
Terminal
(wire connection) Applicable
output load Zero cross
function Rated input voltage
(V) Model
Push-in plus
technology
DC load
DC 12 G3RV-SR500-D DC12
24 G3RV-SR500-D DC24
AC/DC 24 G3RV-SR500-D AC/DC24
48 G3RV-SR500-D AC/DC48
AC
100 G3RV-SR500-D AC100
110 G3RV-SR500-D AC110
200 G3RV-SR500-D AC200
230 G3RV-SR500-D AC230
AC load
Yes
DC 12 G3RV-SR500-A DC12
24 G3RV-SR500-A DC24
AC/DC 24 G3RV-SR500-A AC/DC24
48 G3RV-SR500-A AC/DC48
AC
100 G3RV-SR500-A AC100
110 G3RV-SR500-A AC110
200 G3RV-SR500-A AC200
230 G3RV-SR500-A AC230
No
DC 12 G3RV-SR500-AL DC12
24 G3RV-SR500-AL DC24
AC/DC 24 G3RV-SR500-AL AC/DC24
48 G3RV-SR500-AL AC/DC48
AC
100 G3RV-SR500-AL AC100
110 G3RV-SR500-AL AC110
200 G3RV-SR500-AL AC200
230 G3RV-SR500-AL AC230
Screw technology
DC load
DC 12 G3RV-SR700-D DC12
24 G3RV-SR700-D DC24
AC/DC 24 G3RV-SR700-D AC/DC24
48 G3RV-SR700-D AC/DC48
AC
100 G3RV-SR700-D AC100
110 G3RV-SR700-D AC110
200 G3RV-SR700-D AC200
230 G3RV-SR700-D AC230
AC load
Yes
DC 12 G3RV-SR700-A DC12
24 G3RV-SR700-A DC24
AC/DC 24 G3RV-SR700-A AC/DC24
48 G3RV-SR700-A AC/DC48
AC
100 G3RV-SR700-A AC100
110 G3RV-SR700-A AC110
200 G3RV-SR700-A AC200
230 G3RV-SR700-A AC230
No
DC 12 G3RV-SR700-AL DC12
24 G3RV-SR700-AL DC24
AC/DC 24 G3RV-SR700-AL AC/DC24
48 G3RV-SR700-AL AC/DC48
AC
100 G3RV-SR700-AL AC100
110 G3RV-SR700-AL AC110
200 G3RV-SR700-AL AC200
230 G3RV-SR700-AL AC230
G3RV-SR
13
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Solid state relay for maintenance
Model Number Legend
List of Models
*Different depending on the ambient temperature.
For more details, refer to Load current vs. ambient rated temperature on page 16.
(1) Output voltage
specification
D: DC output
2: AC output
(2) Rated current
02: AC output 2 A
03: DC output 3 A
(3) Terminal
S: Plug-in type
(4) Zero cross functions
Blank: Zero cross function available
L: Zero cross function not available
(5) Rated input voltage
Number: 12, 24, 48 VDC
G3RV-@ @ S @
@
(1) (2) (3)(4) (5)
Insulation
method
Operation
Display
Output
(SSR)
Zero cross
Function
Rated
output
Load *
Rated input
voltage
(socket) Model Applicable model
Photo-
triac
Yes
(green)
AC
Yes
2 A
(at 100 to
240
VAC)
12 VDC G3RV-202S DC12 G3RV-SR700/500-A DC12V
24 VDC G3RV-202S DC24 G3RV-SR700/500-A DC24V
24 VAC/VDC G3RV-SR700/500-A AC/DC24V
48 VAC/VDC
G3RV-202S DC48
G3RV-SR700/500-A AC/DC48V
100 VAC G3RV-SR700/500-A AC100V
110 VAC G3RV-SR700/500-A AC110V
200 VAC G3RV-SR700/500-A AC200V
230 VAC G3RV-SR700/500-A AC230V
No
12 VDC G3RV-202SL DC12 G3RV-SR700/500-AL DC12V
24 VDC G3RV-202SL DC24 G3RV-SR700/500-AL DC24V
24 VAC/VDC G3RV-SR700/500-AL AC/DC24V
48 VAC/VDC
G3RV-202SL DC48
G3RV-SR700/500-AL AC/DC48V
100 VAC G3RV-SR700/500-AL AC100V
110 VAC G3RV-SR700/500-AL AC110V
200 VAC G3RV-SR700/500-AL AC200V
230 VAC G3RV-SR700/500-AL AC230V
Photo-
voltage
coupler
DC
3 A
(at 5 to
24 VDC)
12 VDC G3RV-D03SL DC12 G3RV-SR700/500-D DC12V
24 VDC G3RV-D03SL DC24 G3RV-SR700/500-D DC24V
24 VAC/VDC G3RV-SR700/500-D AC/DC24V
48 VAC/VDC
G3RV-D03SL DC48
G3RV-SR700/500-D AC/DC48V
100 VAC G3RV-SR700/500-D AC100V
110 VAC G3RV-SR700/500-D AC110V
200 VAC G3RV-SR700/500-D AC200V
230 VAC G3RV-SR700/500-D AC230V
G3RV-SR
14
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Specifications
Rating (ambient temperature 25°C)
Input
G3RV-SR700/500-A series
G3RV-SR700/500-AL series
G3RV-SR700/500-D series
Output
Rated input
voltage
Rated current Must operate
voltage Must release
voltage
Input voltage
AC DC Percentage of the
rated voltage
50 Hz 60 Hz
12 VDC 15.0 mA 10.8 V max.
1 V min. ±10%
24 VDC 12.0 mA 21.6 V max.
24 VAC/VDC 11.3 mA 11.4 mA 11.0 mA 21.6 V max.
48 VAC/VDC 6.8 mA 6.9 mA 6.0 mA 43.2 V max.
100 VAC 6.2 mA 6.2 mA 90 V max.
110 VAC 6.2 mA 6.2 mA 99 V max.
200 VAC 3.7 mA 4.4 mA 180 V max.
230 VAC 3.8 mA 4.6 mA 207 V max.
Rated input
voltage
Rated current Must operate
voltage Must release
voltage
Input voltage
AC DC Percentage of the
rated voltage
50 Hz 60 Hz
12 VDC 15.0 mA 10.8 V max.
1 V min. ±10%
24 VDC 12.0 mA 21.6 V max.
24 VAC/VDC 11.4 mA 11.5 mA 11.0 mA 21.6 V max.
48 VAC/VDC 7.7 mA 7.7 mA 6.9 mA 43.2 V max.
100 VAC 7.3 mA 7.3 mA 90 V max.
110 VAC 7.3 mA 7.3 mA 99 V max.
200 VAC 3.8 mA 4.6 mA 180 V max.
230 VAC 3.9 mA 4.7 mA 207 V max.
Rated input
voltage
Rated current Must operate
voltage Must release
voltage
Input voltage
AC DC Percentage of the
rated voltage
50 Hz 60 Hz
12 VDC 8.0 mA 10.8 V max.
1 V min. ±10%
24 VDC 4.6 mA 21.6 V max.
24 VAC/VDC 5.0 mA 5.1 mA 4.3 mA 21.6 V max.
48 VAC/VDC 6.8 mA 6.9 mA 6.0 mA 43.2 V max.
100 VAC 6.2 mA 6.2 mA 90 V max.
110 VAC 6.2 mA 6.2 mA 99 V max.
200 VAC 3.7 mA 4.4 mA 180 V max.
230 VAC 3.9 mA 4.5 mA 207 V max.
Item G3RV-SR700/500-A(L) G3RV-SR700/500-D
Rated load voltage 100 to 240 VAC (50/60 Hz) 5 to 24 VDC
Load voltage range 75 to 264 VAC (50/60 Hz) 3 to 26.4 VDC
Load current
0.1 to 2 A (Ambient temperature=25°C)
100
A to 3 A (Ambient temperature=25°C)
Inrush current resistance 30 A (60 Hz, 1 cycle) 30 A (60 Hz, 1 cycle)
Permissible l
2
t; Joule integral value
(reference value)
15A2s9 A2 s
Applied load capacity 400 W
(Output voltage: 200 VAC)
72 W
(Output voltage: 24 VDC)
G3RV-SR
15
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Characteristics
Approved standards
UL 508 (file No.E64562)
TÜV(EN 62314)
Item G3RV-SR700/500-A G3RV-SR700/500-AL G3RV-SR700/500-D
Operate time 1/2 cycle of load power supply
+1 ms max. 3 ms max. 6 ms max.
Release time 60 ms max. 60 ms max. 60 ms max.
Output ON voltage drop 1.6 V (RMS) max.
Output ON resistance 0.3 max. (at 24 VDC)
Leaked current 5 mA max. (at 200 VAC, 50/60 Hz) 10 µA max. (at 24 VDC)
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength Between input and output 2,500 VAC 50/60 Hz 1 min
Vibration resistance Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm
Shock resistance 300m/s2
Ambient operating temperature Storage: –30 to +100°C (with no icing or no condensation)
Operating: –30 to +55°C (with no icing or no condensation)
Ambient operating humidity 45 to 85% RH
Weight Approx. 38 g
Pollution degree 2
The degree of protection by
IEC60529 IP20
Rated impulse dielectric
strength 4.0 kV/III
Load category LC-A DC-12
Overload current profile 1.5Ie 1.1Ue
5s ON, 10s OFF, 10 cycles
Rated insulation voltage 240 V
Model Input ratings Contact ratings
G3RV-SR700/500-D series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load) at 25°C
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/DC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load) at 25°C
Model Input ratings Contact ratings
G3RV-SR700/500-D series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load)
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load)
G3RV-SR
16
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Engineering Data
Load current vs. ambient rated temperature
G3RV-SR700/500-A(L) series
G3RV-SR700/500-D series
Inrush Current Resistance: Non-repetitive
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.
Product mounting spacing 10 mm (Separate Mounting) Close mounting (up to 5 units *)
Product mounting spacing 10 mm (Separate Mounting) Close mounting (up to 5 units *)
*When five or more are installed, install with 10 mm space between
each.
For details, please refer to Mounting on page 23.
G3RV-SR700/500-A(L) series G3RV-SR700/500-D series
30 −20 0 40 60 80 10055
Ambient temperature (°C)
5
4
3
2
1
0
Load current (A)
20 25 30 −20
0.2
0406080 10055
5
4
3
2
1
020 25
Ambient temperature (°C)
Load current (A)
30 −20 0 40 60 80 10055
5
4
3
2
1
020 25
Ambient temperature (°C)
Load current (A)
30 −20
0.5
0202540 6080 10055
5
4
3
2
1
0
Ambient temperature (°C)
Load current (A)
40
35
30
25
20
15
10
5
0
Inrush current (A.Peak)
10 30 50
100 300 500 1,000 3,000 5,000
Energized time (ms)
40
35
30
25
20
15
10
5
0
10 30 50
100 300 500 1,000 3,000 5,000
Inrush current (A.Peak)
Energized time (ms)
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
G3RV-SR
17
Dimensions (unit: mm)
Solid state relay + socket
Push-in plus technology
G3RV-SR500
A2
A1
A1
A2
12
14
13
12
14
13
Input circuit
Input circuit
* : Diode bridge
: Light emitting diode
A1
13
14
A2
12
Input circuit
A2–
A1+
13 (+)
14 (–)
G3RV
INPUT
OUTPUT
A2–
A1+
13 (+)
14 (–)
G3RV
INPUT
OUTPUT
The information in
parentheses in for
a DC output.
The information in
parentheses in for
a DC output.
A2–
A1+
13 (+)
14 (–)
G3RV
INPUT
OUTPUT
The information in
parentheses in for
a DC output.
65.89
51.72
35.25
18.78
35.25
74.5
18.78
35.3
78.77
(5.05)
(5.05)
59.71
3.4
78 max.
90 max.
6.2 max.
12 VDC
24 VDC
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
Other voltage
G3RV-SR
18
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Screw technology
G3RV-SR700
A2
A1
A1
A2
12
14
13
12
14
13
Input circuit
* : Diode bridge
Input circuit
: Light emitting diode
A1
13
14
A2
12
Input circuit
A2–
A1+
13 (+)
14 (–)
G3RV
INPUT
OUTPUT
A2–
A1+
13 (+)
14 (–)
G3RV
INPUT
OUTPUT
The information in
parentheses in for
a DC output.
The information in
parentheses in for
a DC output.
A2–
A1+
13 (+)
14 (–)
G3RV
INPUT
OUTPUT
The information in
parentheses in for
a DC output.
12 VDC
24 VDC
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
65.89
51.65
35.18
18.71
18.71
35.18
74.5
(5.05)
(5.05)
35.3
78.77
56.2
3.4
78 max.
6.2 max.
90 max.
Other voltage
G3RV-SR
19
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Solid state relay for maintenance
G3RV-D03SL
G3RV-202S(L)
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
G3RV-D03SL (input circuit)
G3RV-202S(L) (input circuit)
33 max.
30.5 max.
2.4
15.8
5.2 max.
3.5
1.8
5.04 3
22
14 13A1 A2
Input
Load
14 13A1 A2
Input
Load
G2RV-SR/G3RV-SR
20
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Safety Precautions
Be sure to read the Safety Precautions for All Relays in the website at the following URL:
http://www.ia.omron.com/.
Format of Warning Indications
Meaning of Graphic Symbols for Ensuring Product Safety
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
Do not touch the terminal section of the G2RV-SR or
the surrounding area while the power is being
supplied. Doing so may result in electric shock.
Minor electrical shock may occasionally occur.
Do not touch the G3RV terminal section (i.e., current
carrying parts) while the power is being supplied.
The G3RV may rupture if short-circuit current flows.
As protection against accidents due to short-circuiting,
be sure to install protective devices, such as fuses and
no-fuse breakers, on the power supply side.
Minor electrical shock may occasionally occur.
Do not touch the main circuit terminals on the G3RV
immediately after the power supply has been turned
OFF.
Shock may result due to the electrical charge stored
in the built-in snubber circuit.
Note: G3RV-202S(L), G3RV-SR500/700-A(L) series
models only
Minor burns may occasionally occur.
Do not touch the G3RV or the heat sink while the
power is being supplied or immediately after the
power supply has been turned OFF.
The G3RV becomes extremely hot.
Provide a space of at least 3 mm between the G2RV-
SR and ground. Not doing so may result in a ground
fault.
Transport
Do not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
Do not drop the product or subject it to abnormal vibration or shock
during transportation or mounting. Doing so may result in
deterioration of performance, malfunction, or failure.
Do not transport the product without it being packaged. Doing so
may result in damage, malfunction, or failure.
Do not transport the G3RV under the following conditions. Doing
so may result in damage, malfunction, or deterioration of
performance characteristics.
High temperature, high humidity conditions
Conditions such as temperature change that causes rapid
condensation
Condition where it is not packaged
Operating and Storage Environments
Do not use or store the product in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
Do not store in locations subject to ambient storage
temperatures outside the range –40 to 70°C (for G2RV) and
outside the range –30 to 100°C (for G3RV).
Locations subject to relative humidity outside the range 5% to
85% (for G2RV) and outside the range 45% to 85% (for G3RV).
Locations subject to high temperature or high humidity.
Conditions such as temperature change that causes rapid
condensation
•L
ocations where corrosive gases or flammable gases are present
Location where rainwater or water droplets gets splashed
Location with splashes of water, oil, and chemicals, etc.
Locations with much dust, salt, and iron powder
Location with blockers
Where static electricity or noise occurs
Where strong electromagnetic field is generated
Where there is a risk of exposure to radioactivity
Do not use or store Sockets in environments that contain silicone
gas, sulfidizing gas (e.g., SO2 or H2S), or organic gas, or near
materials that contain silicone. Doing so may cause the contacts to
be unstable or to fail.
Handling <G3RV>
Keep the G3RV well ventilated.
There is a risk of short-circuiting or burning due to G3RV
overheating.
WARNING
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally, there may be
significant property damage.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury or in property damage.
Precautions
for Safe Use
Indicates supplementary comments on
what to do or avoid doing, to use the
product safety.
Precautions
for Correct
Use
Includes operating precautions to ensure
that the product will operate properly and
that performance and functions will not be
adversely affected.
Indicates the possibility of electric shock under
specific conditions.
Used for general CAUTION, WARNING, or
DANGER precautions for which there is no
specified symbol. (This symbol is also used as
the alerting symbol, but shall not be used in this
meaning on the product.)
Indicates the possibility of explosion or rupture
under specific conditions.
Indicates the possibility of injuries by high
temperature under specific conditions.
WARNING
CAUTION
Precautions for Safe Use
G2RV-SR/G3RV-SR
21
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Mounting
Before you start wiring, please make sure that the socket is
securely attached to the mounting rail. If the socket is unstable, it
may come loose and risk of injury towards the workers.
Please insert the flat-blade screwdriver to the bottom of the hole. If
you do not insert the flat-blade screwdriver correctly, the cable will
not be connected correctly
.
When lubricant such as oil is attached to the tip of the driver, the
driver will fall off, with a risk of injury towards the workers.
Usage
Please select the load within the rated range. Doing so may result
in damage, malfunction, or failure.
Please use the power of the rated frequency. It may cause
malfunction, failure, or risk of burnout.
<G3RV>
Install G3RV according to instructions Mounting on page 23. If you
install in the wrong direction, abnormal heat is generated, and may
lead to short-circuiting or burning the output element.
G3RV is an SSR that generates heat. Please observe the ambient
temperature setting range of G3RV. If installing in an enclosed
space, set a fan, and ventilate.
When mounting G3RV to DIN rail, firmly fits into the groove. If it is
not properly installed, there is a risk of it falling.
Wiring
For the current to be applied, make sure a wire size with margin is used.
Otherwise, excessive heat generated by the wires may cause burning
.
Do not attempt to use the wire if the coat is torn. Not doing so may
result in electric shock.
Always turn OFF the power supply before performing wiring. Not
doing so may cause electrical shock.
<G3RV>
The wires of the socket for G3RV socket should not be passed
through the same duct as that being connected to the high-voltage
power supply. Otherwise, inductive noise may damage the G3RV
or cause it to malfunction.
Push-in plus technology
Do not wire anything to the release holes.
Do not tilt or twist a flat-blade screwdriver while it is inserted into a release
hole on the terminal. The terminal may be damaged
.
Insert a flat-blade screwdriver into the release holes at an angle.
The terminal may be damaged if you insert the screwdriver straight
in.
Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
Do not bend the wire past its natural bending radius or pull on it
with excessive force. Doing so may cause the wire disconnection.
Do not insert more than one wire into each terminal (insertion) hole
.
To prevent wiring materials from smoking or ignition, use the wiring
materials given in the following table.
Note: Use Ferrules with UL certification (R/C).
Disposal
When disposing of the product, do not put into the fire.
Do not use or store the product in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
Where vibration or shock is directly transmitted to the body
Do not use the product where the socket could touch a solvent
or alkaline agent.
Do not insert short bar in the hole for wire or screw driver, it may
cause the result of failure of pull out.
If insert short bar in the hole for wire or screw driver and try to pull
out, it may cause damage for short bar or socket.
Push-in plus technology
1. Connecting Wires to the Push-in plus technology
Part Names of the Terminal
Connecting Wires with Ferrules
Insert the ferrule straight into the terminal until the end strikes the
terminal.
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
The angle should be between 10°and15°. If the flat-blade
screwdriver is inserted correctly, you will feel the spring in the
release hole respond.
(2) With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until it strikes the terminal.
(3) Remove the flat-blade screwdriver from the release hole.
Checking Connections
After insertion, pull gently on the wire to make sure that it will not
come out (i.e., to confirm that it is held by the terminal).
To prevent short circuits, insert the stripped part of a stranded or
the conductive part of a ferrule until it is hidden inside the terminal
insertion hole. (See following diagram.)
Recommended Wire
Stripping length
Ferrules
When using
terminal
Ferrules
When not using
terminal
0.5 to 1.5 mm2/AWG20 to AWG16 10 mm 8 mm
Precautions for Correct Use
Release hole
Te r m i n al (Insertion) hole
Release hole
Terminal
(Insertion) hole
Ferrules
(2)
Flat-blade screwdriver
Stranded Wires
10 to 15°
(1) (3)
(2)
(1)
(3)
G2RV-SR/G3RV-SR
22
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
2. Removing Wires from the Terminal
Use the following procedure to remove wires from the terminal.
The same method is used to remove stranded wires and ferrules.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
(2) With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
(3) Remove the flat-blade screwdriver from the release hole.
3. Recommended ferrules and tools
Recommended ferrules
*1. Make sure that the outer diameter of the wire is smaller than the
inner diameter of the insulating sleeve of the recommended
ferrule.
*2. Make sure that the ferrule processing dimensions conform to the
following figure.
Recommended Flat-blade Screwdriver
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
The following table is the manufacturer and format at the time in
December 2015.
Screw Terminal
Screw terminal
Tightening Torque
0.4 N • m
Electric wiring
Use the electric wire of specified size as shown above. The length
of the that is not covered is 8 mm.
<G2RV>
Operating latching lever (test switch)
When operating the latching lever for G2RV-SR701/501
series, use a 2.5 mm width flat-blade screwdriver.
Applicable flat-blade screwdriver
Flat-blade screwdriver with parallel cutting edge: shaft diameter
2.5 mm (3.0 mm max.)
Always turn OFF the power supply before operating latching lever.
Return to its original state after using the latching lever.
Do not use the latching lever as a switch.
Operation durability of the latching lever is 100 times or more.
Do not keep the latching lever ON for a long period of time (24
hours or more) in order to maintain the operation check function.
Applicable
wire
Ferrules
Conduct
length
(mm)
Recommended ferrules
(mm
2
)(AWG)
Phoenix
Contact
product
Weidmuller
product Wago product
0.5 20 8AI0.5-8 H0.5/14 FE-0.5-8N-WH
0.75 18 8AI0.75-8 H0.75/14 FE-0.75-8N-GY
118 8AI1-8 H1.0/14 FE-1.0-8N-RD
1.5 16 8AI1.5-8 H1.5/14 FE-1.5-8N-BK
Recommended crimp
tool
CRIMPFOX6
CRIMPFOX6T-F
CRIMPFOX10S
PZ6 roto Variocrimp4
Model Manufacturer
XW4Z-00B Omron
ESD 0.402.5 Wera
SZF 0.42.5 Phoenix Contact
0.42.575 302 Wiha
AEF.2.575 Facom
210-719 Wago*1
*1. Insulated types of Flat-blade Screw driver, strongly recommended
to prevent from an electric shock.
SDI 0.42.575 Weidmuller*1
98 20 25 KNIPEX*1
(2)
10 to 15°
Wire
Flat-blade screwdriver
(1) (3)
(2)
(1)
(3)
8 mm
2.1 mm max. 8 mm
Side
0.4 mm
2.5 mm dia.
2.5 mm
Front
Wired type Applicable wire
size Stripping
length
Stranded wires, without
ferrule 0.5 to 1.5 mm28 mm
Stranded wires, with ferrule
and plastic collar 0.5 to 1.5 mm28 mm
Stranded wires with ferrule,
without plastic collar 0.5 to 1.5 mm28 mm
Single wire 0.5 to 1.5 mm28 mm
Stripping length
8 mm
Screw terminal
Shaft diameter 2.5 mm (3.0 mm max.)
Driver with a thick shaft cannot be used.
Wide flat-blade screwdriver
Parallel cutting edge flat-blade screwdriver
G2RV-SR/G3RV-SR
23
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Method of operation of the latching lever (test
switch)
Keep the protective cover open when using the latching lever. Move
until the latching lever clicks to the ON position (ON state). After use
latching lever, in order to prevent malfunction, return the switch to
contact normal position (OFF state), and make sure the protective
cover is firmly closed.
Using the latching lever
Example: check the operation of the relay and the sequence circuit
<G3RV>
Since the G3RV uses electronic components, do not allow it to fall,
vibrate, or apply shock that exceeds the criteria. Doing so may
result in failure, malfunction, or deterioration of performance.
Tighten screw terminal for G3RV at torque 0.4 N · m. It may cause
short-circuit failure or burning.
Please use the voltage and current suitable for the input and output
terminal portion of G3RV. It may cause short-circuit failure or
burning.
Mounting
<The SSR Mounting Pitch (Panel Mounting)>
*When five or more are installed, install with 10 mm space between
each.
<Relationship of SSR and duct (duct depth)>
<Ventilation Outside the Control Panel>
If the air inlet or air outlet has a filter, clean the filter regularly to
prevent it from clogging to ensure an efficient flow of air.
Do not place objects that may obstruct the proper ventilation for
outside or inside the inlet or exhaust port, and in the outside
vicinity.
A heat exchanger, if used, should be located in front of the G3RV
to ensure the efficiency of the heat exchanger.
Please observe the ambient temperature of G3RV. The rated
current of the G3RV is measured at an ambient temperature of
25°C.
The G3RV uses a semiconductor in the output element.
This causes the temperature inside the control panel to increase
due to heating resulting from the flow of electrical current through
the load. The G3RV reliability can be increased by adding a
ventilation fan to the control panel to dispel this heat, thus lowering
the ambient temperature of the G3RV.
(It suggests that life expectancy is doubled by each 10°C reduction
in ambient temperature.)
EMI
The G3RV is a Class A product (for industrial environments).
When used in a residential environment, it may cause radio
interference. In such case, the user may be required to take
appropriate measures.
<Protective cover: locked> <Protective cover: disengage>
Contact normal position
Contact operating position (on-state)
Close protective cover Open protective cover
SSR10 mm min.
30 mm min.
80 mm min.
60 mm min.
Duct or other object blocking airflow
Vertical Direction
Airflow
Metal
base
SSR SSR
Incorrect Example Countermeasure 1 Countermeasure 2
Mounting surface
Mounting surface
Mounting surface
SSR
Duct or other object
blocking airflow
Recommended height of the duct is
1/2 or less of the height of the SSR
Duct or other object
blocking airflow
Vertical
Direction
Duct or other object
blocking airflow
Duct or other object
blocking airflow
Duct or other object
blocking airflow
Duct or
other object
blocking
airflow
Do not enclose the SSR in a
duct of the same height.
It will interfere with the heat
dissipation of SSR.
Use ducts that have a
shallow depth, to provide a
sufficient ventilation area.
If the ducts cannot be made lower,
place the SSR on a metal base so
that it is not surrounded by the ducts.
Height of SSR
SSR
Inlet
Be aware of airflow
Exhaust
(Axial fan)
SSR
SSR
Duct or other object
blocking airflow
G2RV-SR/G3RV-SR
24
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Ordering Information
Short Bars
Note: Use for wiring to the adjacent socket.
*Replace the box (@) in the model number with the code for the covering color. @ color selection: R = red, S = blue, Y = yellow
Label
Separate Plate
PLC interface unit
*Please make sure applicable models, P2RVC can not be used other combination than the above table.
Parts for DIN Track Mounting
*When mounting DIN Track, please use End Plate (PFP-M).
Refer to your OMRON website for details on PFP-@.
For G2RV-SR/G3VR-SR
Common Accessories (order separately)
Appearance Pitch No. of
poles Colors Model * Minimum order
(Quantity)
Maximum energizing
current
6.2 mm
2
Red (R),
Blue (S),
Yellow (Y)
PYDN-6.2-020@
10 32 A
3PYDN-6.2-030@
4PYDN-6.2-040@
10 PYDN-6.2-100@
20 PYDN-6.2-200@
Appearance Model Minimum order (Sheet)
(Pieces per sheet)
XW5Z-P2.5LB2 5
(1 sheet/72 pieces)
Appearance Model
XW5Z-EP12
Appearance I/O classification Connection method Common process Applicable Models *Model
For input
Push-In
PNP
G2RV-SR500-AP
P2RVC-8-I-5-1
NPN P2RVC-8-I-5
Screw PNP G2RV-SR700-AP P2RVC-8-I-7-1
For output
Push-In
PNP G2RV-SR500
G2RV-SR501
G3RV-SR500
P2RVC-8-O-5-1
NPN P2RVC-8-O-5
Screw PNP
G2RV-SR700
G2RV-SR701
G3RV-SR700
P2RVC-8-O-7-1
Appearance Type Model Minimum order
(Quantity)
DIN Tracks
1 m PFP-100N
0.5 m PFP-50N
End Plate *PFP-M
10
Spacer PFP-S
G2RV-SR/G3RV-SR
25
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Applicable Cables
Name Appearance Cable
length L
(mm) Connecting Cables Applicable Connectors
Cables with Loose
Wires
P2RV-A@C
8 I/O
points
1,000 P2RV-A100C
Various devices
2,000 P2RV-A200C
3,000 P2RV-A300C
5,000 P2RV-A500C
Cables with
Connectors (1:4)
P2RV-4-@C
32 output
points
1,000 P2RV-4-100C
PLC I/O Units with MIL connectors (1:4)
CJ1W-OD232/OD262, etc.
2,000 P2RV-4-200C
3,000 P2RV-4-300C
5,000 P2RV-4-500C
Cables with
Connectors (1:4)
P2RV-4-@IMC
32 input
points
1,000 P2RV-4-100IMC
PLC I/O Units with MIL connectors (1:4)
CJ1W-ID232/ID262, etc.
2,000 P2RV-4-200IMC
3,000 P2RV-4-300IMC
5,000 P2RV-4-500IMC
Cables with
Connectors (1:4)
P2RV-4-@IFC
32 input
points
1,000 P2RV-4-100IFC
PLC I/O Units with Fujitsu connectors (1:4)
CJ1W-ID231/ID261, etc.
2,000 P2RV-4-200IFC
3,000 P2RV-4-300IFC
5,000 P2RV-4-500IFC
Cables with Connectors
(1:1)
P2RV-A
@
C-OMR GRT1
8 output
points
500
P2RV-A050C-OMR GRT1
Slice I/O Units (1:1)
For inputs: GRT1-ID8-1
For outputs: GRT1-OD8-1
1,000
P2RV-A100C-OMR GRT1
8 input
points
500
P2RV-A050IC-OMR GRT1
1,000
P2RV-A100IC-OMR GRT1
Cables with
Connectors (1:1)
P2RV-A@C-OMR NX
8 output
points
500 P2RV-A050C-OMR NX
PLC I/O Units with MIL connectors (1:1)
For inputs: NX-ID4442
For outputs: NX-OD4256
1,000 P2RV-A100C-OMR NX
8 input
points
500 P2RV-A050IC-OMR NX
1,000 P2RV-A100IC-OMR NX
End A End B
Device
end
70
PLC interface
unit end
L
L 300
L 300
L 300
L
L
G2RV-SR/G3RV-SR
26
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Schneider Electric
PLC Connecting
Cables
P2RV-@C-SCH-@
32 input
points
500 P2RV-050C-SCH-A
Schneider Electric PLCs with 32-point
connectors (1:4)
For inputs: 140 DDI 353 00
For outputs: 140 DDO 353 00
1,000 P2RV-100C-SCH-A
2,000 P2RV-200C-SCH-A
3,000 P2RV-300C-SCH-A
5,000 P2RV-500C-SCH-A
32 output
points
500 P2RV-050C-SCH-B
1,000 P2RV-100C-SCH-B
2,000 P2RV-200C-SCH-B
3,000 P2RV-300C-SCH-B
5,000 P2RV-500C-SCH-B
16 input
points
500 P2RV-050C-SCH-C
Schneider Electric PLCs with
16-point connectors (1:2)
For inputs: BMX DDI 1602
For outputs: BMX DDO 1602
1,000 P2RV-100C-SCH-C
2,000 P2RV-200C-SCH-C
3,000 P2RV-300C-SCH-C
5,000 P2RV-500C-SCH-C
16 output
points
500 P2RV-050C-SCH-D
1,000 P2RV-100C-SCH-D
2,000 P2RV-200C-SCH-D
3,000 P2RV-300C-SCH-D
5,000 P2RV-500C-SCH-D
Siemens PLC
Connecting Cables
P2RV-@C-SIM-@
32 input
points
500 P2RV-050C-SIM-A
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 321-1BL00-0AA0
For outputs: 6ES7 322-1BL00-0AA0
1,000 P2RV-100C-SIM-A
2,000 P2RV-200C-SIM-A
3,000 P2RV-300C-SIM-A
5,000 P2RV-500C-SIM-A
32 output
points
500 P2RV-050C-SIM-B
1,000 P2RV-100C-SIM-B
2,000 P2RV-200C-SIM-B
3,000 P2RV-300C-SIM-B
5,000 P2RV-500C-SIM-B
16 input
points
500 P2RV-050C-SIM-C
Siemens PLCs with
16-point connectors (1:2)
For inputs: 6ES7 321-1BH02-0AA0
1,000 P2RV-100C-SIM-C
2,000 P2RV-200C-SIM-C
3,000 P2RV-300C-SIM-C
5,000 P2RV-500C-SIM-C
32 input
points
500 P2RV-050C-SIM-D
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 421-1BL-0AA0
For outputs: 6ES7 422-1BL-0AA0
1,000 P2RV-100C-SIM-D
2,000 P2RV-200C-SIM-D
3,000 P2RV-300C-SIM-D
5,000 P2RV-500C-SIM-D
32 output
points
500 P2RV-050C-SIM-E
1,000 P2RV-100C-SIM-E
2,000 P2RV-200C-SIM-E
3,000 P2RV-300C-SIM-E
5,000 P2RV-500C-SIM-E
Name Appearance Cable
length L
(mm) Connecting Cables Applicable Connectors
L 300
End A End B
Device
end
PLC interface
unit end
L 300
L 300
L 300
L 300
G2RV-SR/G3RV-SR
27
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Ratings / characteristices
Electrical schematic
Input
P2RVC-8-I-@-1 (PNP) P2RVC-8-I-5 (NPN)
Output
P2RVC-8-O-@-1 (PNP) P2RVC-8-O-5 (NPN)
PLC interface unit
Rated voltage 30 VAC/DC
Rated current 0.5 A/poles, 2 A/unit
Ambient operating
temperature 40 to 55°C
1....................8
14
11
1
2
3
4
5
6
7
8
9
10
1....................8
14
11
1
2
3
4
5
6
7
8
9
10
1....................8
A2
A1
1
2
3
4
5
6
7
8
9
10
1....................8
A2
A1
1
2
3
4
5
6
7
8
9
10
G2RV-SR/G3RV-SR
28
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Dimensions (unit: mm)
PLC interface unit
12.68
67.16
29
49.60
7×6.20
Push-IN
P2RVC-8-I-5(-1)
P2RVC-8-O-5(-1)
12.68
67.16
29
49.60
7×6.20
Screw
P2RVC-8-I-7-1
P2RVC-8-O-7-1
G2RV-SR/G3RV-SR
29
G2RV-SR G3RV-SR Common AccessoriesCommon Precautions
Dimensions (unit: mm)
Short Bars
Separate Plate
Parts for DIN Track Mounting
Refer to your OMRON website for details on the PFP-@.
(Except for PLC interface unit)
Common Accessories
21.20
L
9
14
6.20
Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
*Replace the box (@) in the model number with the code for the covering color.
Pitch No. of poles L (Length) Colors Model *Maximum carry
current
6.2 mm
2 12.4
Red (R)
Blue (S)
Yellow (Y)
PYDN-6.2-020@
32 A
3 18.6 PYDN-6.2-030@
4 24.8 PYDN-6.2-040@
10 62 PYDN-6.2-100@
20 124 PYDN-6.2-200@
PYDN-6.2-@@ (6.2 mm)
12
63
56
XW5Z-EP12
MEMO
30
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. J214-E2-01A-X 0316(0316)
© OMRON Corporation 2016 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tow e r,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200