MHz Range Crystal unit TSX-3225
Product name TSX-3225 16.000000 MHz 9.0 +10.0-10.0
Product Number / Ordering code X1E0000210019xx
Please refer to the 5.Packing information about xx (last 2 digits)
Pb free / Complies with EU RoHS directive
Reference weight Typ. 17 mg
1.Absolute maximum ratings
Symbol Min. Typ. Max. Unit Conditions / Remarks
T_stg -40 -+125 ºC Storage as single product
T_use -40 -+105 ºC
2.Specifications(characteristics)
Symbol Min. Typ. Max. Unit Conditions / Remarks
f_nom 16.000000 MHz Fundamental
f_tol -10 -+10
x 10-6@+25ºC
f_tem -9 -+9
x 10-6 -20ºC to +75ºC
T_use -20 -+75 ºC
DL 10 100 200 µW
CL 9pF
R1 --60
C1 -2.56 -fF
L1 -38.65 - mH
C0 -1.09 -pF
f_age -1 +1
x10-6 /yea @+25ºC, First year
3.External dimensions (Unit: mm) 4.Footprint(Recommended) (Unit: mm)
5.Packing information
[ 1 ]Product number last 2 digits code (xx) description The recommended code is "17"
X1E0000210019xx
Code Code
01 Any Q'ty vinyl bag(Tape cut) 00 2000pcs / Reel
11 Any Q'ty / Reel 16 3000pcs / Reel
12 250pcs / Reel 17 4000pcs / Reel
14 1000pcs / Reel
Shunt capacitance
Frequency aging
Condition
Condition
Operating temperature
Level of drive
Load capacitance
Motional resistance (ESR)
Motional capacitance
Motional inductance
Frequency Stability over
temperature
Parameter
Storage temperature
Parameter
Nominal frequency
Frequency tolerance
Operating temperature
#1
#4
#2
#3
Internal
connection
#2 and #4
are connected to the cover.
(Please connect to ground)
C 0.3 Min.
0.7
#1
#3
#4
0.8
#2
0.6 Max.
3.2±0.15
#1
#4
2.5±0.15
#2
#3
Marking
1.15
1 Page
[ 2 ] Taping specification
Subject to EIA-481 & IEC-60286
(1) Tape dimensions TE0804L
   Material of the Carrier Tape : PS
   Material of the Top Tape : PET+PE Unit: mm
(2) Reel dimensions
Center material : PS
Material of the Reel : PS Unit: mm
V(mm) W(mm)
9.0+/-0.3 11.4+/-1
φ
1.0
+
0.1
φ
1.5
-
0
4
.0
±
0.1
2.0
±
0.1
4
.0
±
0.1
10 P: 40
±
0.1
3.5
±
0.1
8.0
±
0.2
1.75
±
0.1
0.25
±
0.05
2.9
±
0.1
3.6
±
0.1
1.0
±
0.1
±
0.1
MRAKIN
MRAKIN
Direction of unreeling
2 Page
6.Reflow profile
Reflow condition (Follow of JEDEC STD-020D.01)
7.Notice
Contact us
http://www5.epsondevice.com/en/contact/
Temperature[C]
60
300
250
200
150
100
50
0
ts
60sto180s
(+150Cto+200C)
Avg. Ramp-up
3C/sMax.
Ramp-down
6C/sMax.
Time[s]
120
180
240
300
360
420
480
540
600
660
720
780
Tsmin;+150C
Tsmax;+200C
TL ;+217C
+255C
tL
60sto150s
(+217Cover)
tp;20sto40s
TP ;+260C
Time +25CtoPeak
· This material is subject to change without notice.
· Any part of this material may not be reproduced or duplicated in any form or any means without the written
permission of Seiko Epson.
· The information about applied data,circuitry, software, usage, etc. written in this material is intended for
reference only.
Seiko Epson does not assume any liability for the occurrence of customer damage or infringing on any patent
or copyright of a third party.
This material does not authorize the licensing for any patent or intellectual copyrights.
· When exporting the products or technology described in this material, you should comply with the applicable
export control laws and regulations and follow the procedures required by such laws and regulations.
· You are requested not to use the products (and any technical information furnished, if any) for the development
and/or manufacture of weapon of mass destruction or for other military purposes. You are also requested that
you
would not make the products available to any third party who may use the products for such prohibited
purposes.
· These products are intended for general use in electronic equipment. When using them in specific applications
that require
extremely high reliability, such as the applications stated below, you must obtain permission from Seiko Epson
in advance.
/ Space equipment (artificial satellites, rockets, etc.)
/ Transportation vehicles and related (automobiles, aircraft, trains, vessels, etc.)
/ Medical instruments to sustain life
/ Submarine transmitters
/ Power stations and related
/ Fire work equipment and security equipment
/ Traffic control equipment
/ And others requiring equivalent reliability.
· All brands or product names mentioned herein are trademarks and/or registered trademarks of their respective.
3 Page