Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
ORDERING INFORMATION
SIL type SSR with
9mm thickness
controls up to 3A
AQ8 RELAYS
Please contact us
about TÜV certified
products.
RoHS compliant
FEATURES
1. Slim with 9 mm .354 inch thickness
The thin type (45 mm long × 24 mm high
× 9 mm wide) (1.772×.945×.354 inch)
permits high density mounting.
2. Excellent in noise resistance
Since the input and output are insulated
by the phototriac coupler, the noise on
the output side is not fed back to the input
side.
3. Snubber circuit integrated
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of the voltage on the output side,
such as inductive load and noise.
4. Zero-cross and random types are
available.
The zero-cross type generates minimal
noise by suppressing occurrence of radio
frequency interference (RFI) and electro-
magnetic interference (EMI).
The random type features a short
operation time which permits phase
control.
5. High dielectric strength: 3,000 V AC
(between input and output)
6. Two kinds of terminals distance are
available. (5.08 mm and 7.62 mm) (.200
and .300 inch)
7. High reliability, long life and
maintenance-free
TYPICAL APPLICATIONS
1. Most suitable as drivers for small
size AC motors, solenoids, solenoid
valves and so on.
2. Copying equipment
3. Air conditioners
4. Industrial equipment such as NC
machines, sequencers, robots, etc.
Load current
2 A
3 A
AQ
Input terminal distance
C1: 5.08 mm
C2: 7.62 mm
.200 inch
.300 inch
Input voltage
5, 12, 24 V DC
Load voltage
1: 75 to 125 V AC
2: 75 to 250 V AC
Type
ZT:
T:
Zero-cross type
Random type
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
TYPES
Standard packing: Carton 20 pcs., Case 200 pcs.
RATING
1. Rating (Ambient temperature: 20°C, 68°F; Voltage ripple on the input side: 1% or less)
1) Zero-cross type
• 2 A type
Types Load current Load voltage Input voltage
Input terminals distance
(5.08 mm .200 inch type)
Input terminals distance
(7.62 mm .300 inch type)
Part No. Part No.
Zero-cross type
2A
75 to 125V AC
5 V DC AQ2A1-C1-ZT5V DC AQ2A1-C2-ZT5V DC
12 V DC AQ2A1-C1-ZT12V DC AQ2A1-C2-ZT12V DC
24 V DC AQ2A1-C1-ZT24V DC AQ2A1-C2-ZT24V DC
75 to 250V AC
5 V DC AQ2A2-C1-ZT5V DC AQ2A2-C2-ZT5V DC
12 V DC AQ2A2-C1-ZT12V DC AQ2A2-C2-ZT12V DC
24 V DC AQ2A2-C1-ZT24V DC AQ2A2-C2-ZT24V DC
3A
75 to 125V AC
5 V DC AQ3A1-C1-ZT5V DC AQ3A1-C2-ZT5V DC
12 V DC AQ3A1-C1-ZT12V DC AQ3A1-C2-ZT12V DC
24 V DC AQ3A1-C1-ZT24V DC AQ3A1-C2-ZT24V DC
75 to 250V AC
5 V DC AQ3A2-C1-ZT5V DC AQ3A2-C2-ZT5V DC
12 V DC AQ3A2-C1-ZT12V DC AQ3A2-C2-ZT12V DC
24 V DC AQ3A2-C1-ZT24V DC AQ3A2-C2-ZT24V DC
Random type
2A
75 to 125V AC
5 V DC AQ2A1-C1-T5V DC AQ2A1-C2-T5V DC
12 V DC AQ2A1-C1-T12V DC AQ2A1-C2-T12V DC
24 V DC AQ2A1-C1-T24V DC AQ2A1-C2-T24V DC
75 to 250V AC
5 V DC AQ2A2-C1-T5V DC AQ2A2-C2-T5V DC
12 V DC AQ2A2-C1-T12V DC AQ2A2-C2-T12V DC
24 V DC AQ2A2-C1-T24V DC AQ2A2-C2-T24V DC
3A
75 to 125V AC
5 V DC AQ3A1-C1-T5V DC AQ3A1-C2-T5V DC
12 V DC AQ3A1-C1-T12V DC AQ3A1-C2-T12V DC
24 V DC AQ3A1-C1-T24V DC AQ3A1-C2-T24V DC
75 to 250V AC
5 V DC AQ3A2-C1-T5V DC AQ3A2-C2-T5V DC
12 V DC AQ3A2-C1-T12V DC AQ3A2-C2-T12V DC
24 V DC AQ3A2-C1-T24V DC AQ3A2-C2-T24V DC
Part No.
Item
AQ2A1-C1-
ZT5VDC
AQ2A1-C2-
ZT5VDC
AQ2A1-C1-
ZT12VDC
AQ2A1-C2-
ZT12VDC
AQ2A1-C1-
ZT24VDC
AQ2A1-C2-
ZT24VDC
AQ2A2-C1-
ZT5VDC
AQ2A2-C2-
ZT5VDC
AQ2A2-C1-
ZT12VDC
AQ2A2-C2-
ZT12VDC
AQ2A2-C1-
ZT24VDC
AQ2A2-C2-
ZT24VDC
Remarks
Input
side
Control voltage 5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V) *1
Input impedance Approx. 0.18 kApprox. 0.55 kApprox. 1.4 kApprox. 0.18 kApprox. 0.55 kApprox. 1.4 k
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V Min. 0.5 V Min. 1.2 V Min. 2.4 V
Load
side
Max. load current 2 A*2At ambient temperature of
30°C or less
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
OFF voltage 400 V 600 V
Non-repetitive
surge current 30 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max. carrying current
Min. load current 25 mA*450 mA*4
OFF state dV/dt 50 V/µsAt ambient temperature of
80°C
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
• 3 A type
Notes: *1. Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Characteristics of non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2) Random type
• 2 A type
Part No.
Item
AQ3A1-C1-
ZT5VDC
AQ3A1-C2-
ZT5VDC
AQ3A1-C1-
ZT12VDC
AQ3A1-C2-
ZT12VDC
AQ3A1-C1-
ZT24VDC
AQ3A1-C2-
ZT24VDC
AQ3A2-C1-
ZT5VDC
AQ3A2-C2-
ZT5VDC
AQ3A2-C1-
ZT12VDC
AQ3A2-C2-
ZT12VDC
AQ3A2-C1-
ZT24VDC
AQ3A2-C2-
ZT24VDC
Remarks
Input
side
Control voltage 5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V) *1
Input impedance Approx. 0.18 kApprox. 0.55 kApprox. 1.4 kApprox. 0.18 kApprox. 0.55 kApprox. 1.4 k
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V Min. 0.5 V Min. 1.2 V Min. 2.4 V
Load
side
Max. load current 3 A*2At ambient temperature of
30°C or less
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
OFF voltage 400 V 600 V
Non-repetitive
surge current 80 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max. carrying current
Min. load current 25 mA*450 mA*4
OFF state dV/dt 50 V/µsAt ambient temperature of
80°C
Part No.
Item
AQ2A1-C1-
T5VDC
AQ2A1-C2-
T5VDC
AQ2A1-C1-
T12VDC
AQ2A1-C2-
T12VDC
AQ2A1-C1-
T24VDC
AQ2A1-C2-
T24VDC
AQ2A2-C1-
T5VDC
AQ2A2-C2-
T5VDC
AQ2A2-C1-
T12VDC
AQ2A2-C2-
T12VDC
AQ2A2-C1-
T24VDC
AQ2A2-C2-
T24VDC
Remarks
Input
side
Control voltage 5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V) *1
Input impedance Approx. 0.3 kApprox. 0.8 kApprox. 1.8 kApprox. 0.3 kApprox. 0.8 kApprox. 1.8 k
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V Min. 0.5 V Min. 1.2 V Min. 2.4 V
Load
side
Max. load current 2 A*2At ambient temperature of
30°C or less
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
OFF voltage 400 V 600 V
Non-repetitive
surge current 30 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max. carrying current
Min. load current 25 mA*450 mA*4
OFF state dV/dt 50 V/µsAt ambient temperature of
80°C
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
• 3 A type
Notes: *1. Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
*2. Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. characteristics of non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Ambient temperature: 20°C 68°F; Input voltage ripple: 1% or less)
REFERENCE DATA
Part No.
Item
AQ3A1-C1-
T5VDC
AQ3A1-C2-
T5VDC
AQ3A1-C1-
T12VDC
AQ3A1-C2-
T12VDC
AQ3A1-C1-
T24VDC
AQ3A1-C2-
T24VDC
AQ3A2-C1-
T5VDC
AQ3A2-C2-
T5VDC
AQ3A2-C1-
T12VDC
AQ3A2-C2-
T12VDC
AQ3A2-C1-
T24VDC
AQ3A2-C2-
T24VDC
Remarks
Input
side
Control voltage 5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V) *1
Input impedance Approx. 0.3 kApprox. 0.8 kApprox. 1.8 kApprox. 0.3 kApprox. 0.8 kApprox. 1.8 k
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V Min. 0.5 V Min. 1.2 V Min. 2.4 V
Load
side
Max. load current 3 A*2At ambient temperature of
30°C or less
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
OFF voltage 400 V 600 V
Non-repetitive
surge current 80 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max. carrying current
Min. load current 25 mA*450 mA*4
OFF state dV/dt 50 V/µsAt ambient temperature of
80°C
Type
Item Zero-cross type Random type Remarks
Operate time, max. 1/2 cycle of voltage sine wave + 1 ms 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Insulation resistance, min. 109 between input and output at 500 V DC
Breakdown voltage 3,000 V AC between input and output For 1 minute
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 3 mm 1 hour for X, Y, Z axis
Functional 10 to 55 Hz at double amplitude of 3 mm 10 min. for X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s2 {100 G} 5 times each for X, Y, Z axis
Functional Min. 980 m/s2 {100 G} 4 times each for X, Y, Z axis
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn ON and Turn OFF) Random turn ON, zero-cross turn OFF
1. Characteristics of load current vs. ambient
temperature
Use load current within range specified in the figure
below.
2 A type
3 A type
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
0.5
1.0
1.5
2.0
2.5
3.0
2.-(1) Characteristics of non-repetitive surge
current vs. carrying time
(2 A type)
2.-(2) Characteristics of non-repetitive surge
current vs. carrying time
(3 A type)
510 50100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
20
40
60
80
100
510 50100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
20
40
60
80
100
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
DIMENSIONS (mm inch)
3. Characteristics of input current vs. input
voltage
—zero-cross type
---Random type
(5 V type)
(12 V type) (24 V type)
30
25
20
15
10
5
0
Input voltage, V
Input current, mA
0102030
4.-(1) Characteristics of load current vs.
ambient temperature for adjacent mounting
(2 A type)
Conditions: Natural cooling
4.-(2) Characteristics of load current vs.
ambient temperature for adjacent mounting
(3 A type)
Conditions: Natural cooling
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
0.5
1.0
1.5
2.0
2.5
=20.32 mm
=9.0 mm
=12.7 mm
=Adjacent mounting pitch
.800 inch
.354 inch
.500 inch 2.0
–30 0 20 40 60 80
0
Ambient temperature, °C
Load current, A
=20.32 mm
=9.0 mm
=12.7 mm
=Adjacent mounting pitch
3.0
1.0
.800 inch
.354 inch
.500 inch
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
(Common for zero-cross and random types)
1. Input terminals distance 5.08 mm .200 inch
1) 2 A type External dimensions
General tolerance: ±0.5 ±.020
5.08
5.08
12.7 10.16
45 max.
24 max.
3421
9 max.
8 min.
4-0.8 dia.
2.5
INPUT LOAD
3421
+
.200
.200
.500 .400
1.772
.945
.315
.098
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
Te r minal
Copper foil
43 2 1
2.54×5
4-1.2 dia.
27.94
1.100
.100×5
2.54×2
.100×22.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
2) 3 A type
External dimensions
General tolerance: ±0.5 ±.020
5.08
5.08
12.7 10.16
9 max.
43 max.
32 max.
8 min.
3421
2.5
INPUT LOAD
3421
+
4-0.8 dia.
.200
.200
.500 .400
1.693
1.259
.315
.098
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
Te r minal
Copper foil
43 2 1
2.54×5
4-1.2 dia.
27.94
1.100
.100×5
2.54×2
.100×22.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
2. Input terminals distance 7.62 mm .300 inch
1) 2A type External dimensions
General tolerance: ±0.5 ±.020
7.62
5.08
12.7 10.16
9 max.
45 max.
24 max.
8 min.
34 21
2.5
INPUT LOAD
3421
+
4-0.8 dia.
.200
.500 .400
1.772
.945
.315
.098 .300
4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
43 2 1
Terminal
Copper foil
2.54×5
4-1.2 dia.
30.48
1.200
.100×5
2.54×3
.100×32.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
2) 3A type
External dimensions
General tolerance: ±0.5 ±.020
5.08
12.7 10.16
9 max.
43 max.
32 max.
8 min.
7.62
3421
2.5
INPUT LOAD
3421
+
4-0.8 dia.
.200
.500 .400
1.693
1.259
.315
.098
.300 4-.031
.354
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
43 2 1
Terminal
Copper foil
2.54×5
4-1.2 dia.
30.48
1.200
.100×5
2.54×3
.100×32.54×4
.100×4
4-.047 dia.
INPUT LOAD
34 2 1
Load
power source
+
Load
Input
power source
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ8
ASCTB213E 201201-T1
NOTE
Recommended Temperature Controllers
For Cautions for Use.
1. When used for the load less than
rated
In case of the load current less than
rated, malfunction may result from the
residual voltage across the both ends of
the load even if the solid state relay is
turned off. Use a dummy resistor as a
countermeasure.
The total of the current through the
resistor and the load current must exceed
the min. rated load current.
In case the dummy resistor is not used,
keep in mind that the residual voltage
becomes as follows:
Example:
For the inductive load by the 20 mA load
current and the 200 V AC load voltage,
the load impedance becomes 10 k and
Ve/V = 14% is estimated from the right
above graph. Accordingly, the 28 V
voltage remains across the both ends of
the load when the solid state relay is
turned off.
• Characteristics of residual voltage vs.
load impedance
2. when the terminal is bent
Care shall be taken neither to apply
mechanical stresses to the mold area of
the solid state relay nor to bend the
terminal 45 degrees or more.
R0Dummy resistor
Load
power
source
SSR Load
1
2
010 20
20
40
60
100
80
100
30 40 50
Load impedance (k)
Ve
Ve
V
(%)
V
SSR
1
2
Load
×
f=60Hz
Ve: Residual voltage
V: Power voltage
Power factor:1
(resistor load)
Power factor:0.4
(induction load)
Solder
Printed circuit board
Solid
state relay
Max.
45°
48mm
56mm
1.890inch
2.205inch
48mm
1.890inch
<KT4H Temperature Controller>
Our temperature controller is recommended for use with our Solid State Relays.
Features
• Space saving requiring only a depth of 65 mm
• Data collection possible through a PLC using RS485 communication
Tool port is standard for easy data setting
• Inverted LCD + backlight for good legibility with large characters
• Excellent operability and rich optional control functions
Substitute part numbers
*For detailed product information about temperature controllers, please refer to our website:
http://industrial.panasonic.com/ac/e/
Power supply Control output Part No.
100 to 240 V AC Non-contact voltage output AKT4H112100