651-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
HWS30-1500/ME Series
Features
u Limited Lifetime Warranty
u Medical Approvals2
u Universal Input (85 - 265VAC)
u High Effi ciency
u Broad 30W to 1500W product range
u Wide range AC Input
Single Output Industrial Power Supplies
HWS30 HWS100 HWS300 HWS600 HWS1500
Model HWS50 HWS150
Input Voltage range (47-63Hz) (2) - 85 - 265VAC or 120 - 370VDC 85 - 265VAC or 120 - 330VDC 85 - 265VAC
Input Current (Typ) (1) A 0.8 / 0.4 1.3 / 0.65 4.1 / 2.1 8.1 / 3.9 19 / 10
0.7 / 0.35 1.9 / 0.95
Inrush Current (1) A 14 / 28 20 / 40
Power Factor / Flicker - Meets EN61000-3-2, EN61000-3-3
Temperature Coeffi cient - <0.02%/°C
Overcurrent Protection - >104%
Overvoltage Protection V Yes (See table on page 2)
Hold Up Time (Typ) ms 20
Leakage Current (60Hz) mA <0.5mA
Remote Sense - No Yes
Indicator - Green LED = ON
Remote On/Off - No Yes (Isolated from output)
Parallel operation - No Single wire connection (5 units max)
DC Good - No Yes
Voltage Programming - No Yes
Operating Temperature & Derating °C HWS30-150: -10°C to +70°C, (-10 - +50°C: 100%, +60°C: 60%, +70°C: 20%)
HWS300-1500: -10°C to +70°C, (-10 - +50°C: 100%, derate linearly to 50% load from +50 to +70°C)
Storage Temperature °C -30 to +85°C
Humidity (non condensing) - Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH
Cooling - Convection Internal fan
Withstand Voltage (3) - I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC, O/P to Remote On/Off 100VAC for 1 min.
Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC
Vibration (non operating) - 10 - 55Hz (1 min sweep), 19.6m/s2 constant, X, Y, Z axis, one hour each
Shock (in packaging) - < 196.1m/s2
Safety Agency Approvals (2) - UL60601-1, EN60601, CSA-C22.2 No601.1-M90 (C-UL) (basic insulation), CE Mark
Line Dip - Complies with SEMI F47 (200VAC line only)
Conducted & Radiated EMI - EN55011 / EN55022-B, FCC-B, VCCI-B (HWS600 & 1500 Class A)
Immunity - IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5 (Level 3,4), -8 (Level 4), -11
Weight (Typ) g 220 450 1000 1600 3800
280 500
Size (WxHxD) in 1.04x3.23x3.74 1.1x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 4.98x3.23x11.02
1.04x3.23x4.72 1.46x3.23x6.3
Warranty yrs Limited lifetime warranty (See TDK-Lambda’s terms & conditions)
Specifi cations
(1) 100/200VAC input
(2) See conditions of accep[tability and clause 19.5DV.2 of UL60601 for
equipment in proximity of patient
(3) HWS300-600 2.5kVAC Input to ground
Key Market Segments & Applications