462
Model no.
Rated voltage
Operating voltage range
PWM duty
cycle*
[%]
Rated current
Rated input
Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min-1]
[m³/min]
[CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
9BMB12P2K01
12
10.8 to 13.2 100 3.4 40.8 6850 1.61 56.8 1280 5.14 66
-20 to +70
40000/60˚C
9BMB12P2G01
10.2 to 13.8
100 1.8 21.6 5750 1.34 47.3 760 3.05 61
9BMB12P2S01 100 1.4 16.8 5250 1.22 43.1 610 2.45 59
9BMB12P2H01 100 1.1 13.2 4850 1.11 39.2 490 1.968 57
9BMB12P2F01 100 0.9 10.8 4500 1.04 36.7 410 1.64 56
9BMB24P2K01
24 21.6 to 26.4
100 1.62 38.88 6850 1.61 56.8 1280 5.14 66
9BMB24P2G01 100 0.83 19.92 5750 1.34 47.3 760 3.05 61
9BMB24P2S01 100 0.7 16.8 5250 1.22 43.1 610 2.45 59
9BMB24P2H01 100 0.55 13.2 4850 1.11 39.2 490 1.968 57
9BMB24P2F01 100 0.45 10.8 4500 1.04 36.7 410 1.64 56
* PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%.
The following sensor and control options are available for selection.
Available for all models. Without sensor Pulse sensor
Differs according to the model. Refer to the table on pp. 566 to 567. Lock sensor
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input
Rated speed Max. airow Max. static pressure SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min-1]
[m³/min]
[CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
9BMB12K201
12
7 to 13.2 3.4 40.8 6850 1.61 56.8 1280 5.14 66
-20 to +70
40000/60˚C
9BMB12G201
7 to 13.8
1.8 21.6 5750 1.34 47.3 760 3.052 61
9BMB12S201 1.4 16.8 5250 1.22 43.1 610 2.45 59
9BMB12H201 1.1 13.2 4850 1.11 39.2 490 1.968 57
9BMB12F201 0.9 10.8 4500 1.04 36.7 410 1.647 56
9BMB24K201
24
21.6 to 26.4 1.62 38.88 6850 1.61 56.8 1280 5.14 66
9BMB24G201
12 to 26.4
0.83 19.9 5750 1.34 47.3 760 3.052 61
9BMB24S201 0.7 16.8 5250 1.22 43.1 610 2.45 59
9BMB24H201 0.55 13.2 4850 1.11 39.2 490 1.968 57
9BMB24F201 0.45 10.8 4500 1.04 36.7 410 1.647 56
The following sensor and control options are available for selection.
Available for all models. Without sensor PWM control
Differs according to the model. Refer to the table on pp. 566 to 567. Lock sensor
Blower
97×33 mm
San Ace B97 9BMB type
■General Specications
・ Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
・ Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
rated voltage)
・ Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 547.
・ Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
・ Insulation resistance ………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
・ Sound pressure level (SPL) ……………… At 1 m away from the air inlet
・ Storage temperature ……………………… -30 to +70˚C (Non-condensing)
・ Lead wire ……………………………………… Red Black Sensor Yellow Control Brown
(For models without PWM control function, there is no speed control wiring.)
・ Mass ……………………………………………… 190 g
■Specications
The models listed below have pulse sensors with PWM control function.
The models listed below have pulse sensors.