AQ-E
1
ds_61610_en_aqe: 060207D
ORDERING INFORMATION
1A AC and 3A DC
space saving
PC board terminal type
AQ-E RELAYS
VDE
28.0
15.0
5.0
1.102
.591
.197
mm inch
FEATURES
1. Conforms to European safety
standards (VDE0110)
dielectric distance between input and
output
• Creepage distance: Min. 3.0 mm
• Clearances distance: Min. 2.5 mm
2. The small-sized vertical type
28 mm (L)×5 mm (W)×15 mm
1.063 inch (L)×.197 inch (W)×.591 inch
permits high density mounting to PC
board
3. High dielectric strength: 2,500V AC
(between input and output)
4. Two load types available:
DC output type (3A)
AC output type (1A)
5. Zero-cross ty pe are availale (AC
type)
The zero-cross type generates minimal
noise
6. Snubber circuit integrated (AC type)
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of voltage on the output side, such as
inductive load and current.
TYPES TYPICAL APPLICATIONS
• Interface relays for programmable controllers
• Industrial equipment
• Timers and counters
• Air conditioners
Type Load voltage Input voltage Part No.
AC output 75 to 250 V AC 5 V DC AQE12105
12 V DC AQE12112
24 V DC AQE12124
DC output 3 to 60 V DC 5 V DC AQE34205
12 V DC AQE34212
24 V DC AQE34224
Ex.
Load current Load voltage
1: 1 A
3: 3 A
2: 75 to 250 V AC
4: 3 to 60 V DC
Type
1: AC output (Zero-cross)
2: DC output
(Note) Standard packing: Carton 20 pcs., Case 1,000 pcs.
Input voltage
05: 5 V DC
12: 12 V DC
24: 24 V DC
AQE 12105
AQ-E
2ds_61610_en_aqe: 060207D
SPECIFICATIONS
Ratings (at 20°C 68°F, Input voltage ripple: 1% or less)
Characteristics (at 20°C 68°F, Input voltage ripple: 1% or less)
DIMENSIONS mm inch
Item Type AC output DC output Remarks
Part No. AQE12105 AQE12112 AQE12124 AQE34205 AQE34212 AQE34224
Input
side
Input voltage 4 to 6 V DC 9.6 to 14.4
V DC 21.6 to 26.4
V DC 4 to 6 V DC 9.6 to 14.4
V DC 21.6 to 26.4
V DC
Input impedance Approx.
0.5k ΩApprox.
1.3k ΩApprox.
3k ΩApprox.
0.5k ΩApprox.
1.3k ΩApprox.
3k Ω
Drop-out voltage,
min. 0.5 V DC 1.2 V DC 2.4 V DC 0.5 V DC 1.2 V DC 2.4 V DC
Reverse voltage 3 V
Load
side
Max. load current 1 A AC 3 A DC
Load voltage 75 to 250 V AC 3 to 60 V DC
Frequency 45 to 65 Hz
Non-repetitive
surge current 20 A 15 A AC: In one cycle at 60 Hz
DC: 10 ms
Max. “OFF-state”
leakage current 1.5 mA (applied 200 V) 10μA
Max. “ON-state”
voltage drop 1.6 V 0.3 V at Max. carrying current
Min. load curent 20 mA 1 mA
OFF state dV/dt 50 V/μs—
Max. operating
speed —0.5cps.
at rated operating voltage,
rated load voltage and
current
Item AC output DC output Remarks
Operate time max. (1/2 cycle of voltage sine wave) + 1 ms 2 ms
Release time, max. (1/2 cycle of voltage sine wave) + 1 ms 0.4 ms
Insulation resistance, min. 109 Ω between input and output Using 500 V DC megger
Breakdown voltage 2,500 Vrms between input and output Initial for 1 min.
Vibration
resistance Functional 10 to 55 Hz double amplitude of 1.5 mm 1 hour for X, Y, Z axes
Destructive 10 to 55 Hz double amplitude of 1.5 mm 10 min. for X, Y, Z axes
Shock
resistance
Functional Min. 490 m/s2 {50 G} 5 times each for X, Y, Z
axes
Destructive Min. 490 m/s2 {50 G} 4 times each for X, Y, Z
axes
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn-ON and Turn-OFF)
General tolerance: ±0.5 ±.020
1.2 .047
5.0
.197 28.0 max.
1.102 max.
1.9
.075
15.0 max.
.591 max.
0.5
.020
.020–.004
0.5–0.1
2-.020+.008
-.004
2-0.5+0.2
-0.1
.149–.012
3.78–0.3
2-.039–.004
2-1.0–0.1
–.012
.843
–0.3
21.42 .198–.012
5.04–0.3 3.5–0.5
.138–.020
Mounting hole location (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
AC type
DC type
21.42
.843
5.04
.198
1.9
.075
3.78
.149
2-1.6 dia.
2-.063 dia.
2-1.2 dia.
2-.047 dia.
1.2
.047
Output
+
Input
Input Output
–+ +
AQ-E
3
ds_61610_en_aqe: 060207D
REFERENCE DATA
Cautions for Use
1. Load current vs. ambient temperature 2.-(1) Non-repetitive surge current vs. carrying
time (AC output) 2.-(2) Non-repetitive surge current vs. carrying
time (DC output)
0.5
1.5
1.0
2.0
3.5
3.0
2.5
00–30 20 40 60 80
Ambient temperature, °C
Load current, A
AC type
DC type
0
10
20
30
1 2 3 4 5 7 10 20 30
4050 70 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
10
5
20
15
10 100 1,000
Carrying time, ms
Non-repetitive surge current, A
3. Input current vs. input voltage characteristics 4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
(AC output)
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(DC output)
5
10
15
20
25
30
10502015 25 30
Input voltage, V
Input current, mA
(5 V type) (12 V type) (24 V type)
1.2
1.0
0.8
0.6
0.4
0.2
0200–20 40 60 80 100
Ambient temperature, °C
=15 mm
.591 inch
=10 mm
.394 inch
=5 mm
.197 inch
= Adjacent mounting pitch
Load current, A
3.5
3.0
2.5
2.0
1.5
0.5
1.0
0200-20 40 60 80 100
=15 mm
=10mm
=5mm
Ambient temperature, °C
.591 inch
.394 inch
.197 inch
= Adjacent mounting pitch
Load current, A