Document Number: 78-5102-0126-8 B Issue Date: August 10, 2012
Title: Product Data Sheet Supersedes: Rev B
Subject: 3M™ Active Optical Cable (AOC) Assemblies for CX4 and QSFP+
Applications Page: 4 of 9
3M Electronic Solutions Division
© 3M 2012. All Rights Reserved.
6801 River Place Blvd.
Austin, TX 78726-9000
www.3Mconnectors.com
3.3 Fault
In normal operation, the CX4 module is able to respond to various fault conditions and signal them via the LEDS
and the Fault line on the CX4 connector. The following conditions are recognized:
• RX loss-of-signal. If the Receiver IC detects loss-of-signal on one or more channels then the module will
turn ON the Red LED and pull the fault line low to ground. When the fault is cleared, the Red LED will
turn OFF and the fault line will be pulled low to ground.
• TX fault: If the transmitter detects a transmit fault (laser short or open circuit) it will alternately flashes the
Red and Green LEDs and pulls the fault line low. The module must then be power cycled to continue.
Note: If no fault has occurred then the module will release the Fault line (open-collector output). The host
system is required to supply the recommended 5K-Ohm pull-up resister to this output line.
4.0 LED Indicator Summary
Green LED Red LED Fault line Description
off off low Power has not been applied or module is starting up and has not yet
initialized.
on off low Module is operating normally.
on on Open-collector Receiver has detected loss of signal on one of more channels
flashing flashing Open-collector Alternate flashing of Red and Green LEDs means a laser short or
open circuit has been detected.
5.0 Absolute Maximum Rating
Parameters Min Typ Max Units
Storage temperature -40 +80 Deg. Celsius
Relative humidity 5 85 %
Supply voltage 3.10 3.65 V
Operating case temperature 0 +70 Deg. Celsius
Note: if product is exposed to conditions beyond the levels indicated, the reliability of the product is likely to
be negatively affected.
6.0 Recommended Operating Conditions
Parameter Min Typ Max Units
Supply voltage, Vcc 3.15 3.3 3.57 V
Power dissipation 730 mW
Operating case temperature 0 +70 Deg. Celsius
Differential impedance input/output 100 Ohm
Transmitter differential input voltage 120 1200 mV
Receiver differential output voltage. peak-to-peak 317 mV
Differential input and output impedance 100 Ohm
Signaling rate/channel, NRZ 5.00 Gbps