Maximum ratings, at Tj=25 °C, unless otherwise specified
Parameter Symbol Conditions Unit
Power dissipation
2.5
Operating and storage temperature
IEC climatic category; DIN IEC 68-1 55/150/56
Parameter Symbol Conditions Unit
min. typ. max.
Thermal characteristics
Thermal resistance, junction - case
RthJA 6 cm2 cooling area2) - - 50
Electrical characteristics, at Tj=25 °C, unless otherwise specified
Static characteristics
Drain-source breakdown voltage
V(BR)DSS VGS=0 V, ID=1 mA 25 - - V
VGS(th) VDS=VGS, ID=250 µA 1.2 - 2
Zero gate voltage drain current
VDS=25 V, VGS=0 V,
Tj=25 °C
VDS=25 V, VGS=0 V,
Tj=125 °C
-10 100
Gate-source leakage current
IGSS VGS=20 V, VDS=0 V -10 100 nA
Drain-source on-state resistance
RDS(on) VGS=4.5 V, ID=30 A -3.8 4.8 mW
VGS=10 V, ID=30 A -2.7 3.2
|VDS|>2|ID|RDS(on)max,
ID=30 A
3) See figure 3 for more detailed information
2) Device on 40 mm x 40 mm x 1.5 mm epoxy PCB FR4 with 6 cm2 (one layer, 70 µm thick) copper area for drain
connection. PCB is vertical in still air.
Rev. 2.2 page 2 2013-04-29