Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5202UP Multi-Conductor - Commercial Audio Systems For more Information please call 1-800-Belden1 General Description: Commercial Audio Cable, Rated-CM, 4-16 AWG highly flexible stranded bare copper conductors with PVC insulation, PVC jacket with ripcord Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 4 16 65x34 Bare High-Conductivity ETP Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PVC - Polyvinyl Chloride 0.381 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.381 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm) Twists (twist/m) 76.1997 13.124 Overall Cabling Color Code Chart: Color Black White Red Green Overall Nominal Diameter: 6.198 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 71.434 Kg/Km Max. Recommended Pulling Tension: 578.266 N Min. Bend Radius/Minor Axis: 63.500 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 Page 1 of 2 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5202UP Multi-Conductor - Commercial Audio Systems EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.52496 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 98.43 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 13.2881 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 15.5 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 5202UP D15U1000 1,000 FT 50.000 LB BLUE Notes Item Desc 4 #16 PVC FRPVC 5202UP D15U500 500 FT 25.500 LB BLUE 4 #16 PVC FRPVC 5202UP D151000 1,000 FT 51.000 LB BLUE 5202UP D15500 500 FT 26.000 LB BLUE 5202UP 005U500 500 FT 25.500 LB GREEN, DARK 4 #16 PVC FRPVC 5202UP 0051000 1,000 FT 51.000 LB GREEN, DARK 4 #16 PVC FRPVC 5202UP 005500 500 FT 26.000 LB GREEN, DARK 4 #16 PVC FRPVC 5202UP 008U1000 1,000 FT 50.000 LB GRAY 4 #16 PVC FRPVC 5202UP 008U500 500 FT 25.500 LB GRAY 5202UP 0081000 1,000 FT 51.000 LB GRAY 5202UP 009U1000 1,000 FT 50.000 LB WHITE 4 #16 PVC FRPVC 5202UP 009U500 500 FT 25.500 LB WHITE 4 #16 PVC FRPVC 5202UP 0091000 1,000 FT 51.000 LB WHITE 4 #16 PVC FRPVC 5202UP 010U1000 1,000 FT 50.000 LB BLACK 5202UP 0101000 1,000 FT 51.000 LB BLACK 4 #16 PVC FRPVC C 4 #16 PVC FRPVC 4 #16 PVC FRPVC C 4 #16 PVC FRPVC 4 #16 PVC FRPVC C 4 #16 PVC FRPVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 03-13-2013 (c) 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 2 of 2 01-09-2015