DC-DC CONVERTERS 54-100 W DC-DC Isolated Converters 1
2 YEAR WARRANTY
EXB100 Series
Single output
Ultra wide trim range, 60% to 110% (1.08 Vdc to 5.5 Vdc)
High efficiency, 91.5% @ 5 Vdc, 90.5% @ 3.3 Vdc, 87.5% @ 1.8 Vdc
Basic insulation (input to output)
Industry standard half-brick pin-out
No minimum load
Overvoltage and overtemperature protection
Remote ON/OFF
Available RoHS compliant
The EXB100 series of 100 W single output isolated dc-dc converters are specially
designed to meet the power needs of low voltage silicon. Housed in an open-frame
package with standard footprint, these latest generation converters offer efficiencies as
high as 91.5% (typical on 5 V at 20 A). The series comprises three 48 V input models
with 5 V, 3.3 V and 1.8 V outputs. All models feature a wide input range, trimmable
output voltage and 30 A output (5 V is limited to 20 A). Remote sense and remote
ON/OFF facilities are included as standard, and the converters are comprehensively
protected against overcurrent, overvoltage and overtemperature conditions.
NEW Product
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated SPECIFICATIONS
File Name: exb100s.pdf Rev (02): 05 Dec 2005
OUTPUT SPECIFICATIONS
Voltage adjustability 60% to 110%
Output setpoint accuracy 1.5%
Line regulation Low line to high line ±0.2% max.
Load regulation Full load to min. load ±0.4% max.
Total error band 3.0%
Minimum load 0%
Overshoot At turn-on and turn-off None
Undershoot None
Ripple and noise (See Note 1) 100 mV pk-pk
5 Hz to 20 MHz 50 mV rms
Transient response Deviation 150 mV
(See Note 2) 300 µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range 36-75 Vdc
Input current No load 150 mA
Remote OFF 20 mA
Input current (max.) (See Note 3) 3.15 A max. @ Io max.
and Vin = 36-75 Vdc
Input reflected ripple (See Note 4) 60 mA (pk-pk)
Remote ON/OFF (See Note 5)
Logic compatibility Open collector ref to -input
ON >2 Vdc
OFF <1.2 Vdc
Undervoltage lockout Power up 36 V
Power down 30 V
Start-up time Power up 40 ms
(See Note 6) Remote ON/OFF 35 ms
EMC CHARACTERISTICS
Conducted emissions EN55022 (See Note 7) Level A
EN55022 (See Note 7) Level B
Radiated emissions EN55022 Level A
(See Longform Datasheet)
Immunity:
ESD air EN61000-4-2 8 kV, 15 kV
ESD contact EN61000-4-2 6 kV, 8 kV
Radiated field enclosure EN61000-4-3 10 V/m
Conducted (DC power) EN61000-4-6 10 V
Conducted (signal) EN61000-4-6 10 V (See Note 5)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Basic insulation Input/output 1500 Vdc
Switching frequency 5 V 300 kHz typ.
(Fixed) 3.3 V, 1.8 V 220 kHz typ.
Approvals and TÜV Product Service
standards (See Note 8) UL/cUL60950
Material flammability UL94V-0
Weight 45 g (1.59 oz)
MTBF MIL-HDBK-217F 1,034,000 hours
Representative model: 1.8 V @ 48 Vin, 40 ºC
100% load, ground benign
BELLCORE 332 591,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40 °C to +90 °C
temperature
Non-operating -40 °C to +125 °C
Altitude derating 3,000 m 20%
(above sea level) 10,000 m 50%
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit Continuous
Overvoltage Non-latching clamp
TELECOM SPECIFICATION
Central office interface A ETS300-132-2 input voltage
and current requirements
EXB100 Series
Single output
DC-DC CONVERTERS 54-100 W DC-DC Isolated Converters 2
Please consult our website for the following items: Application Note Longform Datasheet
NEW Product
www.artesyn.com
File Name: exb100s.pdf Rev (02): 05 Dec 2005
2.280±0.02
(57.91±0.5)
1.900
(48.26)
Ø0.040 ±0.002
(Ø1.02 ±0.05)
6 Places Ø0.080 ±0.002
(Ø2.03 ±0.05)
2 Places
Max open-frame
converter height
All dimensions in inches (mm)
General tolerance ±0.01in (±0.25mm)
except where specified otherwise
Minimum clearance from
seating plane to
underside components
0.394
(10.00)
Max
0.138
(3.50)
0.161
(4.09)
0.012
(0.3)
Min
Remote
ON/OFF
1.000
(25.40)
1.400
(35.56)
2.400±0.02
(60.96±0.5)
0.500
(12.70)
Vin-
Vin+
Vo+
Vo-
Trim
Bottom View
Sense-
Sense+
1.400
(35.56)
1.000
(25.40)
0.700
(17.78)
0.500
(12.70)
0.400
(10.16)
seating plane
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service. Certificate No. B 02 02 38572 031
NNootteess
1Measured as per recommended set-up. See Application Note 129 for details.
2di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3Recommended input fusing is a 5 A HRC 200 V rated fuse.
4Measured with external filter. See Application Note 129 for details.
5Signal line assumed <3 m in length.
6Start-up into resistive load.
7The EXB100 meets levels A and B conducted emissions with external
components. See Application Note 129 for details.
8This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example EXB100-48S3V3-RJ.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
11 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
PIN CONNECTIONS
PIN NUMBER FUNCTION
1-Vin
2 No Pin
3 Remote ON/OFF
4+Vin
5 +Vout
6 +Sense
7 Trim
8 -Sense
9 -Vout
OUTPUT
INPUT OVP OUTPUT
OUTPUT OUTPUT
EFFICIENCY REGULATION MODEL
POWER
VOLTAGE VOLTAGE
CURRENT CURRENT
(TYP.) LINE LOAD NUMBER (9,10,11)
(MAX.) (MIN.) (MAX.)
100 W 36-75 Vdc 6.0 Vdc 5 V 0 A 20 A 91.5% ±0.2% ±0.4% EXB100-48S05J
100 W 36-75 Vdc 3.9 Vdc 3.3 V 0 A 30 A 90.5% ±0.2% ±0.4% EXB100-48S3V3J
54 W 36-75 Vdc 2.2 Vdc 1.8 V 0 A 30 A 87.5% ±0.2% ±0.4% EXB100-48S1V8J