AC/DC Power Modules TMM 40 Series, 40 Watt CB Scheme Features Fully encapsulated low profile plastic UL 508 UL 60950-1 UL 60601-1 UL 60950-1 ES 60601-1 casing in PCB- or chassis mount version 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition IT and industrial safety according to IEC/UL 60950-1 and UL 508 Ready to meet ErP directive <0.3W no load power consumption -40C start-up temperature Safety class II prepared Protection against over-temperature overload and short circuit 3-year product warranty The TMM 40 Series of fully encapsulated 40 Watt AC/DC power supply modules feature a reinforced/double I/O isolation system according to latest medical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Protection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of -40C to +60C while it goes up to 75C with 50% load derating. EMI/EMC characteristics and the safety approval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in industrial an commercial environment. Also see: TMM 24 Series, 24 Watt www.tracopower.com/products/tmm24.pdf TMM 60 Series, 60 Watt www.tracopower.com/products/tmm60.pdf Models Order code Output power max. Output 1 Output 2 Efficiency PCB mount Chassis mount TMM 40105 TMM 40105C 5.0 VDC / 8000 mA 81 % TMM 40112 TMM 40112C 12 VDC / 3330 mA 84 % TMM 40115 TMM 40115C 15 VDC / 2660 mA 85 % TMM 40124 TMM 40124C TMM 40212 TMM 40212C +12 VDC / 1660 mA -12 VDC / 1660 mA 84 % TMM 40215 TMM 40215C +15 VDC / 1330 mA -15 VDC / 1330 mA 85 % www.tracopower.com 40 W 24 VDC / 1660 mA 84 % Page 1 of 5 AC/DC Power Modules TMM 40 Series 40 Watt Input Specifications Input voltage ranges - nominal 100 - 240 VAC - AC input 85 - 264 VAC - DC Input 120 - 370 VDC Input frequency 47 - 440 Hz Input current at full load (115 VAC / 230 VAC nominal input) 5 VDC models: 710 mA / 430 mA typ. other models: 690 mA / 415 mA typ. Leakage current 80 A typ. No-Load power consumption <0.3 W External input fuse required (recommended value) 3 A slow blow type or characteristic C Output Specifications Voltage set accuracy 2% typ. Minimum load no minimum load required Regulation - Input variation0.5% typ. - Load variation (0 - 100%) single output models: 1.0% typ. dual output models: 2.0% typ. Temperature coefficient 0.02 %/K Ripple and noise (20 MHz bandwidth) 5.0 VDC model: 1.8% of Vout [Vp-p] max. other models: 1.3% of Vout [Vp-p] max. Current limitation above 105 % of rated output current. hiccup, auto recovery Overvoltage protection by Zener diode (main output only) 120 % of Vout typ. Short circuit protection continuous, automatic recovery Max. capacitive load 5.0 12 15 24 12 15 VDC VDC VDC VDC VDC VDC model: model: model: model: model: model: 8000 F 3900 F 3900 F 680 F 1500 F (each output) 1000 F (each output) All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 5 AC/DC Power Modules TMM 40 Series 40 Watt General Specifications Temperature ranges - Operating (natural convection cooling 20 LFM) -40C to +80C - Power derating above +60C 3.75 %/K - Storage (non operating) -40C to +95C Over temperature protection shutdown: above 90C (at 142C internal IC temeperature) automatic recovery: at approx 67C Humidity (non condensing) 95 % rel max. Altitude during operation 5000 m Switching frequency (pulse width modulation PWM) 130 kHz typ. Hold-up time 115 VAC: 25 ms typ. 230 VAC: 80 ms typ. Isolation voltage - Input/Output 4`000 VAC Isolation resistance - at 500 VDC 1`000 MOhm Reliability /calculated MTBF (MIL-HDBK-217F, at +25C, ground benign) >200'000 h EMI / RFI conducted and radiated EN 55022, class B, FCC part 15, level B EN 55011 class B Electromagnets compatibility - Electrostatic discharge ESD IEC / EN 61000-4-2, 8kV/4kV perf. criteria A (EMC), immunity - RF field immunity IEC / EN 61000-4-3, 10V/m perf. criteria A - Electrical fast transients/burst immunity IEC / EN 61000-4-4, 2kV perf. criteria A - Surge IEC / EN 61000-4-5, 1kV perf. criteria A - Conducted RF IEC / EN 61000-4-6, 10 Vr.m.s perf. criteria A - Magnetic field immunity IEC / EN 61000-4-8, 30 A/m perf. criteria A - Voltage dip and interruptions (115 VAC / 60 Hz) IEC / EN 61000-4-11 30%,10ms perf. criteria A IEC / EN 61000-4-11 60%,10ms perf. criteria A IEC / EN 61000-4-11 95%, 5s perf. criteria B Protection class II acording IEC/EN 60536 Safety standards UL 60950-1, IEC/EN 60950-1, IEC/EN 60601-1 3rd edition, 2 x MOPP ANSI/AAMI ES60601-1:2005(R)2012 UL 508 for chassis mount version - Certification documents www.tracopower.com/overview/tmm40 Casing material plastic resin (UL 94V-0 rated) Environmental compliance - Reach www.tracopower.com/products/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 5 AC/DC Power Modules TMM 40 Series 40 Watt DIN-Rail Mounting Kit Adapter for mounting on DIN-rails as per EN 50022-35 (snap-on mounting) DIN-Rail Mounting Kit Order code For models TMP-MK2 TMM 40xxxC Kit contains interface plate, DIN-rail clip and necessary screws. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 4 of 5 AC/DC Power Modules TMM 40 Series 40 Watt Outline Dimensions TMM 40: for PCB mount: 63.5 (2.50) 5 7 5.0 30.0 (1.18) (0.20) (1.10) 5.0 27.94 (1.10) (0.20) 27.94 3 53.3 (2.1) 31.6 (1.24) 88.9 (3.50) 81.3 (3.20) 2 x M4 THD 15.9 (0.63) Bottom view 3.8 27.94 (1.10) 27.94 (1.10) (0.15) 1 2 0.7 (0.03) Weight: 310 g (10.94oz) 6.0 (0.24) 31.75 (1.25) Pin diameter o 1.0 mm (0.039) TMM 40C: for chassis mount: 63.8 (2.51) 34.1 (1.34) 50.0 (1.97) 3 4 5 6 6.9 5.0 11.8 (0.27) (0.20) (0.46) Pinout / Connection 7 4 x o3.5 92.0 (3.62) 112.0 (4.41) Top view 100.0 (3.94) Indication LED Pin/con. Single Dual 1 AC (N) AC (N) 2 AC (L) AC(L) 3 +Vout +Vout 4 No Pin / NC No Pin / NC 5 -Vout Common 6 No Pin / NC No Pin / NC 7 NC -Vout NC = not to connect 10.0 Weight: 320 g (11.29oz) (0.39) 6.0 2 (0.24) 1 Dimensions in[mm], () = Inches Tolerances = 0.5mm (0.02) Pin diameter o 0.1 mm (0.004) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com www.tracopower.com Rev. January 24. 2018 Page 5 of 5 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TRACO Power: TMM 40105 TMM 40124 TMM 40112 TMM 40115C TMM 40124C TMM 40115 TMM 40105C TMM 40212 TMM 40215C TMM 40212C TMM 40215 TMM 40112C