Features * * * * * * Unregulated Converters Qualified with 65kV/s @ Vcommon mode =1KV UL/CSA and IEC/EN safety certified High isolation 6.4kVDC Optional continuous short circuit protection /X2 version with >9mm input/output clearance Suitable for IGBT applications Description The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA60950-1 as well as EN60950-1. This makes them ideal for medical and safety applications where approved isolation is required. Selection Guide Part Number nom. Input Voltage [VDC] Output Voltage [VDC] Output Current [mA] Efficiency typ. (1) [%] max. Capacitive Load (2) [F] RxxP3.3S (3,4) 5, 12, 15, 24 3.3 303 70 2200 RxxP05S (3,4) 5, 12, 15, 24 5 200 70 - 75 1000 RxxP09S (3,4) 5, 12, 15, 24 9 111 70 - 75 1000 RxxP12S (3,4) 5, 12,15, 24 12 84 70 - 75 470 5, 12, 15, 24 15 66 75 - 80 470 RxxP3.3D (3,4) 5, 12, 15, 24 3.3 151 70 1000 RxxP05D (3,4) 5, 12, 15, 24 5 100 70 - 75 470 RxxP09D (3,4) 5, 12, 15, 24 9 55 70 - 75 470 (3,4) 5, 12,15, 24 12 41 70 - 75 220 RxxP15D (3,4) 5, 12, 15, 24 15 33 75 - 80 220 12, 24 +15/-9 +33/-56 70 - 80 220 5 +15/-9 42 70 - 80 +68/-220 RxxP15S RxxP12D (3,4) RxxP1509D (3,4) R05P1509D (3,4) Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter DC/DC Converter RxxPxx 1 Watt SIP7 Single and Dual Output E224736 EN/IEC62368-1 certified UL/CSA60950-1 certified UL/CSA62368-1 certified Model Numbering R__P__ _/P/X2 Input Voltage Output Voltage Pinout (3) Protection (4) Single or Dual Notes: Note3: add suffix /X2" for single output with alternative pinout Note4: add suffix P" for continous short circuit protection Ordering Examples: R05P05S/P = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection R05P3.3D/P = 5V Input, 3.3V Output, Dual Output, Continous Short Circuit Protection R05P05S/P/X2 = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection, Alternative Pinout www.recom-power.com/eval-ref-boards www.recom-power.com REV.: 5/2018 www.recom-power.com/bier ECO-1 RxxPxx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Input Voltage Range Max. 10% 0% Minimum Load (5) all types PxxP1509D Internal Operating Frequency Output Ripple and Noise 20kHz 20kHz 50kHz 60kHz 85kHz 20MHz BW 200mVp-p Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met PxxP05S and PxxP09S PxxP05D and PxxP09D 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 10 0 0 10 20 30 40 50 60 70 80 90 50 40 30 R05P05S R12P05S R05P09S R12P09S 20 60 R05P05D R12P05D R05P09D R12P09D 20 10 0 100 0 10 20 30 Output Load [%] PxxP12S and PxxP15S 60 70 80 90 100 PxxP12D and PxxP15D 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] 50 Output Load [%] 100 60 50 40 30 60 50 40 30 20 20 R12P12S R24P12S R24P15S 10 0 40 0 10 20 30 40 50 60 70 80 90 R12P12D R24P12D R24P15D 10 100 0 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy Line Regulation Load Regulation 5.0% max. low line to high line, full load 10% to 100% load 3.3, 5VDC 9, 12, 15VDC 1.2%/1% of Vin typ. 15% typ. 10% typ. continued on next page www.recom-power.com REV.: 5/2018 ECO-2 RxxPxx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) Output Voltage [%] Tolerance Envelope +10% +5% +5% Typical L o ad Line Vnom -1.5% -5% 10 50 100 Load [%] Deviation vs. Load PxxP05D and PxxP09D 25 20 20 15 15 Deviation [%] Deviation [%] PxxP05S and PxxP09S 25 10 5 0 R05P05S R05P09S R12P05S R12P09S -5 -10 -15 0 10 20 30 10 5 0 R05P05D R05P09D R12P05D R12P09D -5 -10 40 50 60 70 80 90 -15 100 0 10 20 30 Output Load [%] 20 20 15 15 10 5 0 -15 10 20 30 50 60 70 80 90 100 Output Load [%] www.recom-power.com 80 90 100 70 80 90 100 5 0 R12P12D R24P12D R24P15D -10 40 70 10 -5 R12P12S R24P12S R24P15S 0 60 PxxP12D and PxxP15D 25 Deviation [%] Deviation [%] PxxP12S and PxxP15S -10 50 Output Load [%] 25 -5 40 -15 0 10 20 30 40 50 60 Output Load [%] REV.: 5/2018 ECO-3 RxxPxx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Type Value without Suffix "/P" with Suffix "/P" Short Circuit Protection (SCP) Isolation Voltage (7) I/P to O/P 1 second continuous tested for 1 second 6.4kVDC rated for 1 minute 3.2kVAC/60Hz Isolation Resistance 15G min. Isolation Capacitance 4.0pF min. / 10pF max. Insulation Grade basic Notes: Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note8: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type ENVIRONMENTAL Parameter Condition Operating Temperature Range Value without derating @ free air convection(see graph) Operating Altitude -40C to +90C 2000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 MTBF according to MIL-HDBK-217F, G.B. +25C +85C 2974 x 103 hours 728 x 103 hours Derating Graph (@ Chamber and free air convection) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 95 Ambient Temperature [C] www.recom-power.com REV.: 5/2018 ECO-4 RxxPxx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety E224736-A56-UL UL60950-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 60950-1, 2nd Edition, 2014 Information Technology Equipment, General Requirements for Safety SPCLVD1602031 EN60950-1:2006 +AM:2013 IEC60950-1:2005, 2nd Edition +AM:2013 Audio/video, information and communication technology equipment. Safety requirements E224736-A56-UL UL62368-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 62368-1, 2nd Edition, 2014 Audio/video, information and communication technology equipment. Safety requirements ATTCB106076 EAC IEC62368-1:2014, 2nd Edition EN62368-1:2014 +A11:2017 RU-AT.49.09571 TP TC 004/2011 RoHs 2+ RoHS-2011/65/EU + AM2015/863 EMC Compliance Condition Electromagnetic compatibility of multimedia equipment Emission requirements Standard / Criterion with external filter EN55032, Class A/B EMC Filtering Suggestions according to EN55032 Class A and Class B C3 L1 L1 +VIN +VOUT C1 +VIN C2 C1 -VIN -VOUT Component List Class A -VIN Component List Class B C1 L1 C3 C1 C1 L1 C3 10F 100V MLCC - - 10F 100V MLCC 10F 100V MLCC 470H choke WE 744 045 120 2n2F 8kV Vishay HGZ222MBP DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB non-conductive black plastic, (UL94 V-0) silicon rubber compound, (UL94 V-0) FR4, (UL94 V-0) Dimension (LxWxH) 19.5 x 9.8 x 12.5mm Weight 4.3g typ. continued on next page www.recom-power.com REV.: 5/2018 ECO-5 RxxPxx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) embossed logo 9.8 Pin Connection Pin # Single 1 +Vin 2 -Vin 5 -Vout 6 No Pin 7 +Vout Marking 0.51 12.5 19.5 0.250.05 4.10 0.50+0.10/-0.05 Recommended Footprint Details 6 7 2.4 5 2.54 Bottom View 1 2 3x2.54= 7.62 1.9 1 2 Tolerance: Dual +Vin -Vin -Vout Com +Vout /X2 +Vin -Vin No Pin -Vout +Vout xx.x= 0.5mm xx.xx= 0.25mm 5 6 7 Top View 2.54 6x2.54= 15.24 INSTALLATION AND APPLICATION IGBT Application Circuit IGBT Driver Control Signal Rg IGBT +VOUT 1 -VIN 7 Isolated DC/DC Converter C1 + 2 5 6 C2 + C3 + -VOUT PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 22.3 x 12.0mm Packaging Quantity tube Storage Temperature Range 25pcs -55C to +125C Storage Humidity 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 5/2018 ECO-6