120W Single Output Industrial DIN RAIL EDR-120 series oe ne fe & Wn)us R33100 EAL @ Features @ Applications * Universal AC input / Full range * Industrial control system * Protections: Short circuit / Overload / Over voltage * Semiconductor fabrication equipment / Over temperature * Factory automation * Cooling by free air convection * Electro-mechanical apparatus * Can be installed on DIN rail TS-35/7.5 or 15 * UL 508 (industrial control equipment) approved * EN61000-6-2(EN50082-2) industrial immunity level * 100% full load burn-in test * 2 years warranty @ Description EDR-120 is one economical slim 120W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current. EDR-120 is designed with metal housing that enhances the unit's power dissipation. With working efficiency up to 88.5%, the entire series can operate at the ambient temperature between -20C and 60C under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN60950-1, and etc.) make EDR-120 a very competitive power supply solution for industrial applications. i Model Encoding EDR - 120-(12| Le Output voltage Output wattage Series name File Name:EDR-120-SPEC 2018-01-12MW EDR-120 series 120W Single Output Industrial DIN RAIL SPECIFICATION MODEL EDR-120-12 EDR-120-24 EDR-120-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0~10A 0~5A 0~2.5A RATED POWER 120W 120W 120W RIPPLE & NOISE (max.) Note.2| 100mVp-p 120mVp-p 150mVp-p OUTPUT | VOLTAGE ADJ. RANGE 12~14V 24 ~ 28V 48 ~ 55V VOLTAGE TOLERANCE Note.3} 2.0% 1.0% 1.0% LINE REGULATION +0.5% +0.5% 0.5% LOAD REGULATION 1.0% 1.0% +1.0% SETUP, RISE TIME 1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 10ms/115VAC at full load VOLTAGE RANGE Note.6) 90 ~ 264VAC 127 ~ 370VDC | [DC input operation possible by connecting AC/L(+), AC/N(-)] FREQUENCY RANGE 47 ~ 63Hz pur EFFICIENCY (Typ.) 85% | 87.5% | 88.5% AC CURRENT (Typ.) 2.25A/115VAC 1.3A/230VAC INRUSH CURRENT (Typ.) 20A/115VAC 35A/230VAC LEAKAGE CURRENT <1mA/240VAC OVERLOAD 105 ~ 130% rated output power _ __ Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 14~17V 29 ~ 33V 56 ~ 65V a eee Protection type : Shut down o/p voltage, |= on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. -20 ~ +60C (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~+85C, 10 ~ 95% RH TEMP. COEFFICIENT +0.03%/C (0 ~ 50C ) VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 SAFETY STANDARDS UL508, TUV EN60950-1, EAC TP TC 004, BSMI CNS14336-1 approved;(meet EN60204-1) SAFETY & | WITHSTAND VOLTAGE IP-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC EMC ISOLATION RESISTANCE /P-O/P, IIP-FG, O/P-FG:>100M Ohms / 500VDC / 25C/ 70% RH (Note 4) EMC EMISSION Compliance to EN55032 (CISPR32) Class A, EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class A EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 MTBF 474,6K hrs min. MIL-HDBK-217F (25C) OTHERS | DIMENSION 40*125.2113.5mm (W*H*D) PACKING 0.6Kg; 20pcs/13Kg/1.16CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. Derating may be needed under low input voltage. Please check the derating curve for more details. 7. The ambient temperature derating of 3.5C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft) File Name:EDR-120-SPEC 2018-01-12BALA + >0W Single Output Industrial DIN RAIL EDR-120 series Hi Block Diagram fosc : 70OKHz EMI FILTER POWER RECTIFIERS . 5 ay IP & SWITCHING 7 & Loy RECTIFIERS FILTER T 0.C.P. | | O.L.P. DETECTION Fe PWM ee CIRCUIT _ bd O.T.P. CONTROL Wye O.V.P, Hi Derating Curve Hi Static Characteristics 230VAC [ | 100 eo 12v(230VAC) | 100 A / \ 24V,48V(230VAC) 90 7 80 + 80 415VAC r 1 60) / 7 707 4 mol 42V,24V,48V(115VAC) = 4ob- | = 7 | < Z 50- J o 4 20+ sgl | -20 -10 0 10 20 30 40 45 50 60 = 70 (VERTICAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMPERATURE (C) INPUT VOLTAGE (V) 60Hz File Name:EDR-120-SPEC 2018-01-12MW 120W Single Output Industrial DIN RAIL EDR-1 20 series @ Mechanical Specification 113.5 Top View 40 1234 39 Side View Hf Installation Instruction Back View Hi Installation Manual TB2 +VAD. OV DC OK O 125.2 Front View xe) es 5, res XQ < <2 oe, o) QR CR PES BERG? PEO esese LOS ) eo, < <) BCOOOOO, o, XQ <2 <2 o) c) Re eo OOS AQ (pl Q Hy) 4 Q Q Bottom View J w - aS ~5 a i ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) Please refer to : http://www.meanwell.com/manual.html Case No.992D Unit:mm Side View Terminal Pin No. Assignment (TB1) Pin No. | Assignment 1 FG 2 ACIN or DC - 3 AC/L or DC + Terminal Pin No. Assignment (TB2) Pin No. | Assignment 1,2 DC OUTPUT -V 3,4 | DC OUTPUT+V This series fits DIN rail T$35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. File Name:EDR-120-SPEC 2018-01-12