* VPD-110A 100W 2, 4 Output Switching Supply Features *Universal AC input / Full range *Protections:Short circuit/Over load/Over voltage *Cooling by free air convection *With power good signal output(Optional) *100% full load burn-in test *Fixed switching frequency at 45KHz *2 year warranty CH1 DC output voltage Output V. tolerance Output rated current Output current range Ripple & noise Line regulation Load regulation DC output power Efficiency DC voltage adj. Input voltage range AC current Inrush current Leakage current Overload protection Over voltage protection Over temp. protection Temperature coefficient Set up, rise, hold up time Power good Vibration Withstand voltage Isolation resistance Working temp., humidity Storage temp., humidity Dimensions Weight Safety standards EMC standards Notes: CH2 5V 12V 2% 6% 5A 6.5A 0.5-5A 0.5-6.5A 100mVp-p 150mVp-p 1% 2% 1% 5% 103W 75% CH1:+10,-5% 100~264VAC 47~63Hz; 141~370VDC (90~100VAC 90% load max.) 3A/115V 1.5A/230V cold start 50A <1mA/240VAC 105%-135% type: Hiccup mode, recovers automatically after fault condition is removed CH1:5.75~6.75V ------0.03% / C (0~50C) ON +5V output 1.2s, 50ms, 20ms >=1ms 10~500Hz, 2G 10 min./1 cycle, period fo 60 min. each axes I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min. I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min. -10C~+50% (refer to output derating curve), 20%-90% RH -20C~+85C, 10%-95% RH 7x4.25x1.88 inches (178x108x46 mm) 1.1 lbs. (0.5 Kg) UL1950, TUV EN60950 CISPR22 (EN55022) CLASS B 1. All parameters are specified at 230VAC input, rated load, 25C 70% RH ambient 2. Tolerance includes set up tolerance, line regulation, load regulation 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uF & 47 uF capacitor 4. Line regulation is measured from low line to high line at rated load 5. Output provided up to maximum current, but related to maximum output power 6. Each output provide up to maximum current, but total load cannot exceed max. output power 7. C2, C3, C11 must be removed *V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer's applications using V-Infinity products other than repair or replacing (at V-I's option) V-Infinity products not meeting V-I's published specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 * VPD-110A 100W 2, 4 Output Switching Supply Block Diagram Rectifiers & Filter EMI Filter I/P Rectifiers & Filter Power Switching FG V3 Rectifiers & Filter V2 Rectifiers & Filter V1 Com Detection Circuit PWM Control O.L.P. Regulator O.V.P. fosc: 45KHz Static Characteristics Output Derating Load (%) 80 60 Natural Convection Cooling 40 20 -10 -10 0 0 10 Model: PD-110A 13 5.2 12 5.0 11 4.8 10 4.6 9 4.4 8 4.2 7 4.0 Ta=25C Output Ripple (mVp-p) 17CFM Forced Air Cooling (20cm) Output Voltage (V) 100 300 250 200 150 100 50 25 90 100 110 120 140 160 180 200 220 240 260 20 30 40 50 60 (Horizontal) Input Voltage (V) 60Hz Ambient Temp. (C) Dimensions (mm) 177.8 Model/Pin No. 1,2,3 8,9,10 PD-110A +5V +12V PD-110B +5V +24V 165.1 5 T4A/250V 3 1 12 107.95 CN1 95.25 Terminal Pin No. Assignment CN1: MOLEX 5273-05 PIN 3,5: AC INPUT PIN 1: FG CN2: MOLEX 5273-12 PIN 1,2,3: DC OUTPUT V1 PIN 4,5,6,7: DC OUTPUT COM PIN 8,9,10: DC OUTPUT V2 PIN 11,12: DC OUTPUT V3 OPTION 1 CN2 +5V Adj. 4-3.96 V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 47.75 Mating Connectors CN1,2 Mating Connector Type Molex 5195 Series or equivalent with Molex 5194 or equivalent crimp terminals. www.v-infinity.com 1-866-372-1258