SAC-2P-M12MSB/ 0,3-910/M12FSB Order No.: 1507340
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1507340
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com Nov 18, 2010
Insulation resistance ≥ 100 MΩ
Length of cable 0.3 m
Ambient temperature (operation) -25 °C ... 90 °C (Male connector / female connector)
General characteristics
Coding B - inverse
Surge voltage category II
Pollution degree 3
Degree of protection IP65/IP67/IP69K
Insertion/withdrawal cycles ≥ 100
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 66
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, (nickel-plated)
Sealing material NBR
Status display No
Conductor data
Cable type PROFIBUS
Cable type (abbreviation) 910
Conductor cross section 0.25 mm²
AWG signal line 24
Conductor structure signal line 19x 0.13 mm
Core diameter including insulation 2.55 mm ±0.07 mm
External cable diameter 7.80 mm
Wire colors Red, green
External sheath, color Violet, RAL 4001
Insulation resistance ≥ 5 GΩ*km
Conductor resistance ≤ 78.4 Ω/km
Working capacitance 32 pF (core-core)
Wave impedance Nom. 150 Ω ±10 %
Nominal voltage, conductor 30 V
Test voltage Core/Core 1500 V
Type of pair shielding Aluminum-lined polyester foil
Overall twist 2 cores with 2 fillers to the core