Auxiliary Contact Block General Characteristics: Products Reference Standard Protection Degree Pollution Degree Temperature Vibration Resistance Shock Resistance conforming to IEC 68-2-27 Working Position Mechanical Life :P ush Buttons, Selector Switches, Latching Mushroom Head Push Buttons, Pilot Lights & Illuminated Push Buttons : IEC 60947-5-1, EN 60947-5-1, IEC 337-1 : IP 65/IP 66 according to IEC 60947-1; NEMA4, 4X :3 : - 40C to +70C (Storage) -25C to +70C (Working) :M ushroom Head Push Buttons: 8g, Other Push Buttons & Pilot Lights: 15g (40 to 500Hz) confirming to IEC 68-2-6 :P ush Buttons: 70g, Mushroom Head Push Buttons: 15g, Selector Switches: 200g : All Working Position are Allowed :P ush Buttons & Selector Switches 1 million Operations, Emergency Mushroom Push Buttons 300,000 Operations Contact elements Characteristics: Rated Thermal Current Ith Rated Insulation Voltage Ui Operating Force Dielectric Strength Insulation Resistance Initial Contact Resistance Short Circuits Protection Terminal Reference Connections Contact Operation Operation Frequency Utilization Category : 10A : 500V Conforming to NF C 20-040, VDE 0110 :P ush Buttons - 1 `NO' = 10N, 1 `NC' = 8N Additional Contacts - `NO' = +5N, `NC' = +3N : 2.5kV for 1 minute : 2.5M min (500V DC) : 25m : 10A 500V, Cartridge Fuse g1 or N Conforming to IEC 337-1 : Conforming to CENELEC EN 50013 : On Screw to non Losable Plate Lamp sec. 2.5mm2 max. (14AWG) : Self Cleaning Type, Slow Action, Positive Opening : 3,600 Operation per hour : AC 15 (DC 13) www.element14.com www.farnell.com www.newark.com Page <1> 03/06/13 V1.0 Auxiliary Contact Block Rated Power Conforming to IEC 60947-5-1 Load Factor: 0.5 DC Supply Power Broken in Watts for 1 million Operations AC Supply (50/60Hz) Voltage 24V 48V 120V Inductive Load 65W 48W 40W AC Ratings, Inductive - NEMA A600 35% Power Factor Volts Make Amperes 120 60 240 30 480 15 600 12 VA Break Amperes VA Continuous Carrying Amperes Resistive 75% Power Factor Make, Break & Continuous Amperes 720 10 10 6 7,200 3 1.5 1.2 Part Number Table DC Ratings, NEMA Type Q600 Inductive and Resistive Volts Make & Break (Amp) 125 0.55 250 0.27 600 0.1 Continuous (Amp) Description Part Number Contact Block, 1NO RB2-BE101. Contact Block, 1NC RB2-BE102-BP 2.5 22mm Switches N/C Block RB2-BE102 22mm Switches N/O Block RB2-BE101-BP Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. (c) Premier Farnell plc 2012. www.element14.com www.farnell.com www.newark.com Page <2> 03/06/13 V1.0