GENERAL DESCRIPTION
The HMD5000 is a small hand held unit with actual case dimensions of 3.60 x 5.70 x 2.09 inches. It weighs 0.54
pounds. The interface cable is 3 feet long and has a female 9-pin “D” connector. The accuracy and resolution of the
HMD500 is dependent on the instrument with which it is used — the HMR3000 Digital Compass Module or the
HMR2300 Smart Digital Magnetometer.
Input Power Requirements
Supply Voltage 6-15 Vdc Unregulated
Power 72 mA @ 9 Vdc (300mA at Power Up)
Interface
Interface Cable Pin Assignments
Pin Name Description
2 RD RS-232 Receive In
3 TD RS-232 Transmit Out
5 GND Power and Signal Ground
9 V+ Unregulated Power
When outputting data the LCD display
is divided into four quadrants. Each
quadrant being 8 segments wide.
When connected to the HMR2300
Smart Digital Magnetometer the
display outputs magnetic field strength
data in the X, Y and Z axes along with
Magnitude. Magnitude is calculated
using the formula: √ X2 + Y2 + Z2.
Figure 1 illustrates this output in both
the “Gauss” and “Counts” mode.
If the display is interfaced to an
HMR3000 Digital Compass, the output
consists of Heading, Pitch and Roll
data with Status indicators for each
reading if it is out of range. Figure 2
shows the compass output in both
Degree and Mils mode.
900262 4-00
Honeywell reserves the right to make changes to any products or technology herein to improve reliability, function or design. Honeywell does not assume any liability
arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others.
Solid State Electronics Center
12001 State Highway 55
Plymouth, MN 55441
http://www.ssec.honeywell.com
Figure 1. Sample output when connected to an HMR2300
Figure 2. Sample output when connected to an HMR3000
HMD2300
+ 1 . 0 2 9 7 - 0 . 1 3 5 6
- 0 . 9 8 9 1 + 1 . 5 4 8 2
+ 1 5 , 4 4 6 - 2 , 0 3 4
- 1 4 , 8 3 7 + 2 3 , 2 2 3
Gauss Mode Counts Mode
X-Axis Y-Axis
Z-Axis MagnitudeMagnitude
X-Axis Y-Axis
Z-Axis
HMD3000
Degrees Mode Mils Mode
2 6 5 . 4 ° C H
- 0 . 5 P + 1 4 . 2 R
3 9 4 M O P O R
- 2 5 P + 7 6 8 R
*Status Output will only appear on the display if one of the indicators is something other than “N”
(Normal)
Heading Status
Pitch RollRoll
Heading Status
Pitch