Conductive Level Controller
61F-GPN-BT/-BC
Battery (24 VDC) allows use in locations
without AC power supply. AC sine-wave
voltage between electrodes enables stable
detection with no electric corrosion.
Outputs can be set to self-hold at ON or OFF using special cir-
cuits.
Adjustable sensitivity, with an operating resistance range of 0 to
100 kΩ, allows use for a wide variety of liquids.
Relay contact chattering conventionally caused by waves elimi-
nated using open collector output, reducing contact wear.
Meets CE marking and is a UL recognized component.
Refer to Safety Precautions for Floatless Level
Controllers.
Features
The 61F can now run on DC power to allow energy savings, greater safety, and use in
emergency situations.
Ordering Information
Note: A variety of Holders are available to suit different types of application. For details, refer to 61F Floatless Level Controller
(F030-E1-8).
Product name Model number
Conductive Level Controller 61F-GPN-BT 24VDC 61F-GPN-BC 24VDC
Open collector (NPN) Relay contact (SPST-NO)
Front Socket PF113A-E
Electrode Holder (See note.)
Upper limit
Mid-point
Lower limit
Valve
Short-circuit
Pump
Chattering
Load
Open Collector Output
Combines DC Power
Supply with AC Sensing
Method
AC sine-wave signals are
sent to electrodes using a
built-in DC-AC converter,
preventing electric
corrosion and ensuring
safety.
Oscillator
circuit
Detector
circuit
Supports Multi-channel
Sensing
Power supply circuits and
detection circuits are
isolated, allowing more
than one Controller to be
used in the same tank. Control output
is possible for
upper limit,
mid-point, and
lower limit.
Signals can be used as
direct input for a PLC.
PNP output is also
possible using the
connection method.
Same Wiring for Supply
and Drainage
Supply control and
drainage control can be
performed with the same
wiring (short terminals 7
and 8 for supply control).
This makes it easy to
perform wiring and
confirm connection.
Drainage
control
Supply
control
61F-GPN-BT/-BC
2
Specifications
Ratings
Note: 1. The 61F may not operate at resistance settings close to zero. Adjust the sensitivity to match actual usage conditions.
2. The figure for wiring distance above is for when 600-V 3-core cabtire cable with a cross-sectional area of 0.75 mm2 is used.
Characteristics
Note: The dielectric strength is measured between power terminals
and electrode terminals, power terminals and output terminals,
and between electrode terminals and output terminals.
Connections
Automatic Drainage Operation
Note: The part within the dotted-line box is for the 61F-GPN-BC (relay-output type) only.
Automatic Water Supply Operation
Short terminals 7 and 8 for automatic water supply operation. (Operation shown in parentheses in the diagram above.)
61F-GPN-BT 61F-GPN-BC
Rated voltage 24 VDC
Allowable voltage range 85% to 110% of the rated voltage
Interelectrode voltage 5 VAC max.
Operation resistance (See note 1.) Variable (0 to 100 kΩ)
Error For scale of 0: +10 kΩ; For scale of 100: ±10 kΩ
Release resistance 200% max. of the operation resistance
Switching between supply and drainage Terminals 7 and 8 open: Automatic drainage operation
Terminals 7 and 8 shorted: Automatic supply operation
Output specifications Open collector (NPN)
30 VDC, 100 mA max.
Leak current: 100 μA max.
Relay output, SPST-NO
5 A, 240 VAC (Resistive load)
5 A, 30 VDC
Life expectancy --- Electrical: 100,000 operations min.
Mechanical: 20,000,000 operations min.
Accessories Hold-down clip PFC-N8
Wiring distance (See note 2.) 100 m max.
Ambient operating temperature 10 to 55°C
Ambient operating humidity 25% to 85%
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength (See note.) 2,000 VAC, 50/60 Hz for 1 minute
Power consumption 2 W max.
Response time Operating: 1.5 s max.
Releasing: 3.0 s max.
7
8
4
E2
E3
E1
11
10
3 9
5
6
11
10
24 VDC
OUT+
OUT
OUT+
OUT
Pump ON (OFF)
Pump OFF (ON)
61F-GPN-BT
(See note.)
Open collector
output
Relay contact
output
Supply/
drainage
selection
terminals
61F-GPN-BT/-BC
3
Reading Signals for the Liquid Level Only (No Control)
Only E1 and E3 are used. Output will turn ON when the liquid level reaches E1 if terminals 7 and 8 are open, and will turn OFF if terminals 7 and
8 are closed. Also, to take signals for liquid level at several points, use terminal 4 as a common for all of the Controllers and use terminal 5 of each
Controller as an electrode.
Note: If terminals 7 and 8 are shorted, operation of the 61F relay is “de-energizing” (i.e., energized normally and de-energized when liquid is
present across the electrodes). Therefore, if the power supply connected across terminals 3 and 9 is interrupted, the output from terminals
10 and 11 will turn OFF, enabling detection of power interruptions.
Dimensions
Application Examples
49.4
38 70
84
61F-GPN
-BT/-BC
PF113A (Order Separately)
101
61F-GPN-BT/-BC Use a PFC-N8 Mounting Bracket to mount the
Level Controller to a PF113A Rail-mounted
Socket.
PFC-N8
Note: PFC-N8 Mounting Bracket (provided with
the Level Controller)
t = 0.3
4.5
83
4
6
Approx.
80
ONOFF
Battery
Applications
Liquid level control for solar
power generation systems.
Drainage control for semiconductor
wafer cleaning installations.
Liquid level control for remote
regions without AC power supply.
Meet safety standards by
using DC power supply for
all devices in a panel.
Liquid level control for waste-heat
recovery boilers in co-generation
systems.
Cut costs by using the 61F in situations
where ultrasonic/electrostatic capacity
level controllers were used because
only DC power supply was available.
1
2
Number of
controllers
required:
61F-GPN-BT/-BC
4
Safety Precautions
Refer to Safety Precautions for Floatless Level Controllers.
General Precautions
Before using the Controller under conditions not described in the rel-
evant documents or applying the Controller to nuclear control sys-
tems, railroad systems, aviation systems, vehicles, combustion
systems, medical equipment, amusement machines, safety equip-
ment and other systems, machines, and equipment that may have a
serious influence on lives and property if used improperly, consult
your OMRON representative.
Make sure that the ratings and performance characteristics of the
Controller are sufficient for the systems, machines, and equipment
and be sure to provide the systems, machines, and equipment with
double safety-mechanisms.
Safety Precautions
In order to ensure safe operation, be sure to observe the following
points.
Use a power supply voltage within the specified range.
Do not use the Controller in locations subject to flammable gases
or objects.
Insert the Socket until it securely clicks into place.
Do not short the load connected to the output terminals.
Do not connect the power supply in reverse.
Correct Use
Mounting
Mount to a panel of thickness 1 to 5 mm.
Do not mount the Controller in the following places.
Locations subject to strong vibrations or shocks.
Locations outside the specified temperature and humidity ranges,
or locations prone to condensation. (The Controller detects high
impedances. Do not use in locations subject to high humidity lev-
els.)
Locations subject to dust.
Locations subject to corrosive gases (in particular, sulphurized gas
or ammonia gas).
Outdoors, or in locations subject to direct sunlight.
Near devices that generate strong, high-frequency noise (e.g.,
high-frequency welders, machines).
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2013.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2013 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
61F-GPN-BC 24VDC 61F-GPN-BT 24VDC