Alpha
Flat Cable
Letter ÒQÓ In Stock Number Indicates Direct Factory Shipment To You ALLIED
c
297
Flat Cable Ñ 100' Coils
See Table Below For Cut Lengths
Gray Flat Cable
0.050" Centers UL2651. 28 AWG,
7
/
36
stranded tinned copper conductors, gray PVC insulation with red stripe on the
leading edge. Rated: 105¡C, 300 volts.
943-4041 3580/9 9 0.45" 20.60 18.73
943-1311 3580/10 10 0.50" 22.85 20.77
943-1312 3580/14 14 0.70" 32.03 29.12
943-4042 3580/15 15 0.75" 34.27 31.16
943-1314 3580/16 16 0.80" 36.72 33.38
943-1315 3580/20 20 1.00" 45.70 41.54
943-1316 3580/24 24 1.20" 54.88 49.89
943-1317 3580/25 25 1.25" 57.12 51.93
943-1318 3580/26 26 1.30" 59.57 54.15
943-1319 3580/34 34 1.70" 77.93 70.84
943-4043 3580/37 37 1.85" 84.66 76.96
943-1320 3580/40 40 2.00" 91.60 83.27
943-1321 3580/50 50 2.50" 114.44 104.04
943-4044 3580/60 60 3.00" 137.29 124.81
943-4045 3580/64 64 3.20" 146.47 133.16
Stock Mfr.Õs Number of Overall
No. Type Cond. Width
PER 100' COIL
1-4 5-9
Thermally-Bonded Color-Coded Flat Cable
0.050" Centers UL20029. 28 AWG,
7
/
36
stranded tinned copper conductors, color coded PVC insulation, colors repeat
every 10 conductors. Rated: 105¡C, 300 volts.
943-4046 3583/9 9 0.45" 50.18 45.62
943-1322 3583/10 10 0.50" 53.04 48.22
943-1323 3583/14 14 0.70" 74.46 67.69
943-4047 3583/15 15 0.75" 79.76 72.51
943-1324 3583/16 16 0.80" 85.07 77.33
943-1325 3583/20 20 1.00" 106.28 96.62
943-1326 3583/24 24 1.20" 128.72 117.02
943-1327 3583/25 25 1.25" 132.80 120.73
943-1328 3583/26 26 1.30" 138.11 125.55
943-1329 3583/34 34 1.70" 180.74 164.31
943-4048 3583/37 37 1.85" 196.66 178.78
943-1330 3583/40 40 2.00" 214.61 195.10
943-1331 3583/50 50 2.50" 265.61 241.46
943-4049 3583/60 60 3.00" 318.85 289.87
943-4050 3583/64 64 3.20" 340.07 309.15
Stock Mfr.Õs Number of Overall
No. Type Cond. Width
PER 100' COIL
1-4 5-9
Shielded Jacketed Gray Flat Cable
0.050" Centers UL2912. Suggested for FCC Docket 20780 application. 28 AWG,
7
/
36
stranded tinned copper conductors.
Gray PVC insulation with red stripe on the leading edge. Overall aluminum/mylar/aluminum shield with two drain wires.
Gray PVC jacket .030" minimum average thickness.
943Q1332 3590/9 9 0.52" 209.71 190.65
943Q1333 3590/15 15 0.82" 257.45 234.04
943Q1334 3590/25 25 1.32" 429.22 390.20
943Q1335 3590/37 37 1.95" 536.72 487.93
Stock Mfr.Õs Number of Overall
No. Type Cond. Width
PER 100' COIL
1-4 5-9
Flat Cable Cut Lengths
Order flat cable lengths per the information below. Lengths from 1 to 99 feet may be ordered. Price is per foot. For
100 foot lengths, order from the cables above. Available in gray.
Stock Mfr.Õs Number of PER
Code
No.* Type Cond. FOOT
942-09XX 3580/9 9 0-9 .43
942-10XX 3580/10 10 0-10 .49
942-12XX 3580/14 14 0-14 .68
942-08XX 3580/15 15 0-15 .73
942-13XX 3580/16 16 0-16 .77
942-14XX 3580/20 20 0-20 .96
942-15XX 3580/24 24 0-24 1.17
942-16XX 3580/25 25 0-25 1.21
942-17XX 3580/26 26 0-26 1.26
942-18XX 3580/34 34 0-34 1.65
942-11XX 3580/37 37 0-37 1.79
942-19XX 3580/40 40 0-40 1.94
942-20XX 3580/50 50 0-50 2.43
942-35XX 3580/60 60 0-60 2.92
942-36XX 3580/64 64 0-64 3.11
942-37XX 3583/9 9 1-9 1.06
942-21XX 3583/10 10 1-10 1.12
942-22XX 3583/14 14 1-14 1.58
942-38XX 3583/15 15 1-15 1.70
942-23XX 3583/16 16 1-16 1.80
942-24XX 3583/20 20 1-20 2.26
942-25XX 3583/24 24 1-24 2.72
942-26XX 3583/25 25 1-25 2.82
942-27XX 3583/26 26 1-26 2.92
942-28XX 3583/34 34 1-34 3.83
942-39XX 3583/37 37 1-37 4.17
942-29XX 3583/40 40 1-40 4.46
942-30XX 3583/50 50 1-50 5.51
942-40XX 3583/60 60 1-60 6.64
942-41XX 3583/64 64 1-64 7.07
Jacketed Shielded Cable (2 drain wires)
942-31XX 3590/9 9 9-9 4.36
942-32XX 3590/15 15 9-15 5.36
942-33XX 3590/25 25 9-25 8.92
942-34XX 3590/37 37 9-37 11.16
*Insert footage where XX appears in the stock number.
Contact the closest sales office for quantity pricing.
943-5151 3585/25 25 .34" 187.88 170.80
943-5152 3585/26 26 .39" 189.92 172.66
943-5153 3585/40 40 .40" 268.06 243.69
943-5154 3585/50 50 .46" 376.38 342.16
Stock Mfr.Õs No. of Nom.
No. Type Cond. Dia.
PER 100' COIL
1-4 5-9
Round-to-Flat Cable 0.050" Centers Ñ
UL 2651/20381
Description
c
Mass Terminated Round Cable
c
Flat Cable on 0.50" Centers
c
Supershield
ª
Aluminum/Polyester Tape Plus 90% Tinned Copper Braid
Application
c
Specially Designed for Routing in Cramped Spaces Where the Mess Termination Capabilities of Flat Cable Is
Required and the Flexibility of Round Cable Is Needed
Color-Coded Twist-To-Flat Cable 0.050" Centers Ñ
UL 20184
Flat Cable Ñ 100' Coils Gray Flat Cable 0.025" Centers Ñ
UL 2678
943-5171 3586/26 26 1.30" 195.64 177.85
943Q5172 3586/40 40 2.00" 295.80 268.91
943Q5173 3586/50 50 2.50" 418.20 380.18
943Q9174 3586/60 60 3.00" 451.66 410.60
Stock Mfr.Õs No. of Nom.
No. Type Cond. Dia.
PER 100' COIL
1-4 5-9
943-5051 3582/26 26 .65" 70.58 64.17
943-5052 3582/40 40 1.00" 108.53 98.66
943-5053 3582/50 50 1.25" 135.46 123.14
943-5054 3582/60 60 1.50" 162.59 147.81
Stock Mfr.Õs No. of Nom.
No. Type Cond. Dia.
PER 100' COIL
1-4 5-9
Description
c
30 AWG, Solid Copper Conductors on 0.025" Centers
c
Gray PVC Insulation With Red Strips on Leading Edge
c
UL Recognized Style 2678
c
Resists Acids, Alkalis, Oil, Moisture, Solvents, Ozone and Fungus
c
Passes UL VW-1 Flame Test
Application
c
Easy Termination to 0.025" IDC Connectors
c
Low Cost Alternative to Fluorocarbon Transmission Cables
c
For New Generation of Surface Mounted Connectors With Reduced Contact Spacing
Description
c
28 AWG 7/36 Stranded Tinned Copper Conductors, PVC Insulation
c
10 Standard Color Repeat With Tan as the Common Color in Each Pair
c
Overall Cable Thickness .037" Mates With all 0.50" IDCs
c
High Stability .007" Laminated Film is Needed to Increase Dimensional Stability
c
Twisted Length 18", Flat Length 2"
c
UL Recognized. Style 20184 (Internal Use Only)
Application
c
Ideal for Situations Where Reduced Crosstalk is Necessary Such as High Speed Data Transmission in Computers,
Cash Registers, and Communications Equipment
7