Nuclear Event Detector
HSN-1000
©2005 Maxwell Technologies
All rights reserve d.
01.07.05 Rev 3
FEATURES:
Detects ionizing radiation pulses
100% tested/certified detection threshold level
Adjustable circumvention period
100% testable with built-in test
Detection threshold adjustability
Single +5V operation
Radiation hardness guaranteed
Compliant to MIL-PRF-38534 Class H1
Flat pack (F) or DIP (L) packages
RADIATION HARDNESS
CHARACTERISTICS:
Dose Rate (operate-through): 1 x 1012 rad(Si)/sec
Total Dose: 1 x 106 rad(Si)
Neutron Fluence: 5 x 1013 n/cm2
Approximate Detection Range: 2 x 105 - 2 x 107 rad(Si)/sec
Maxwell Technologies Specified, Controlled, Tested and
Guaranteed
DESCRIPTION:
Maxwell Technologies’ HSN-1000 radiation-hardened Hybrid
Nuclear Event Detector (NED) senses ionizing radiation pulses
generated by a nuclear event, such as the detonation of a nuclear
weapon, and rapidly switches its output from the normal high
state to a low state with a propagation delay time of less than
20ns. The active low Nuclear Event Detection signal (NED) is
used to initiate a wide variety of circumvention functions, thus
preventing upset and burnout of electronic components. The NED
output is als o used to initiat e both hardware and software recov-
ery. This high-speed, 14-pin hybrid detector is used in electronic
systems as a general-purpose circumvention device to protect
memory, stop data processing, and drive power supply switches
as well as signal clamps.
The HSN-1000 is guaranteed to operate through three critical
environments: ionizing dose rate [1012 rad(Si)/s], gamma total
dose [106 rad(Si)], and neutron fluenc e [5 x 1013 n/cm2]. In addi-
tion, the device is designed to function throughout the transient
neutron pulse. The hybrid’s discr ete design ensures a cont rolled
response in these radiation envir onments as well as immunity to
latchup. Each HSN-1000’s detection level and functionality are
tested in an ionizing dose rate environment. A certificate is pro-
vided with each serialized hybrid, reporting the radiation test
results and guaranteeing its performance. The device is also lot
qualified in the total dose and neutron environments to ensure
performance.
The detection threshold of the HSN-1000 is adj ustable within the
range of 2 x 105 rad(Si)/s to 2 x 107 rad(Si)/s. This detection level
can be preset by Maxwell or adjusted by the user. Less than a
30% variation in detection threshold can be expected over the
entire operating temperature range.
1. Manu factured for Max well Techn ologies by Teledyne Microelect r onic
Techn ologies to M IL- P R F -38 534, Cla s s H, no RHA
Detector
(Pin Diode) Amplifier Pulse Timer
LED
457
6
8 9 14 1
2
V
H
V
L
Threshold
Adjust
V
B
BIT
GND CRC
NED
10 k
Logic Diagram
M
e
m
o
r
y
2
All data sheets are subject to change without notice
©2005 Maxwell Technologies
All rights reserve d.
Nuclear Event Detector HSN-1000
01.07.05 Rev 3
TABLE 1. PIN DESCRIPTION
PIN NUMBER PIN FUNCTION
1 Load Voltage, VL
2 Nuclear Event Detector, NED
3 No Connection
4 External Capacitor
5 External Capacitor
6 Built In Test, BIT
7 Package Ground and Case
8 PIN Diode Bias, VB
9 Threshold Adjust
10 No Connection
11 No Connection
12 No Connection
13 No Connection
14 Hardened Supply Voltage, VH
TABLE 2. ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL CONDITIONS
-55°C < TA < 125°CMIN MAX UNIT GROUP A
SUBGROUP
Hardened Supply Voltage VH4.5 5.5 V 1,2,3
Hardened Supply Current
- Standby 1
- Operational 2
IHVH = 5.5V --
--
--
30
120
mA 1,2,3
Load Voltage VL-- 20 V 1,2,3
Load Current
- Standby 1
- Operational 2
ILVL = 20V --
-- 100
2.25 µA
mA
1,2,3
PIN Diode Bias Voltage - Standby 1 V
B4.5 20 V 1,2,3
PIN Diode Bias Current - Standby 1IB-- 100 µA 1,2,3
Built-In-Test (BIT) 3,4 VIH
IIH
VIL
IIL
tPW
VIH = 4.0V
VIL = 0.5V
Pin 9 Open, VIH = 4.0V
4.0
--
--
--
10
5.5
25
0.5
10
--
V
mA
V
µA
µs
7,8
1,2,3
7,8
1,2,3
9,10,11
NED VOH
VOL
VL = 20V, IOH = -100 µA
IOL = 10 mA
IOL = 100 mA
18.5
--
--
--
0.6
1.0
V 1,2,3
1,2,3
Radiation Propagation Delay Time 5tD-- 20 ns
M
e
m
o
r
y
3
All data sheets are subject to change without notice
©2005 Maxwell Technologies
All rights reserve d.
Nuclear Event Detector HSN-1000
01.07.05 Rev 3
MECHANICAL DIMENSIONS
Note: All dimensions in inches.
1. Standby mode is the normal state of the device, defined as having the NED output (pin 2) in the “high” state.
2. Operational mode is in effect during the timeout period of the NED signal, characterized by having the NED output in the “low
state, causing the greatest current draw of the device.
3. BIT electrical characteristics are not guaranteed over the radiation range.
4. BIT may not meet specification when only a resistor is used to adjust the detection level. To use BIT in this situation, it is
advised that a series resistor/capacitor combination is used.
5. Guaranteed but not tested over temperature. Time delay, tD, is measured at 50% points from the rising edge of the radiation
pulse to the falling edge of the NED output at approximately 10 times the detection level.
0.600
0.015 ± 0.003
0.100
TYP
0.500
MIN
0.495
0.795
0.145 MAX
0.070 ± 0.002
0.010 ± 0.002
14 13 12 11 10 9 8
1234567
14 13 12 11 10 9 8
1234567
0.795
0.600
0.100 TYP
0.495
0.300
0.145 MAX
0.200
0.016
0.020DIA
TOP VIEW
Flatpack Hybrid Package
HSN-1000F
DIP Hybrid Package
HSN-1000L
All tolerances are ± 0.005 unless specified
Table 2. Notes
M
e
m
o
r
y
4
All data sheets are subject to change without notice
©2005 Maxwell Technologies
All rights reserve d.
Nuclear Event Detector HSN-1000
01.07.05 Rev 3
Important Notice:
The specifications presented within these data sheets represent the latest and most accurate information available to
date. However, these specifications are subject to change without notice and Maxwell Technologies assumes no
responsibility for the use of this information.
Maxwell Technologies’ products are not authorized for use as critical components in life support devices or systems
without express written approval from Maxwell Technologies.
Any claim against Maxwell Technologies must be made within 90 days from the date of shipment from Maxwell Tech-
nologies. Maxwell Technologies’ liability shall be limited to replacement of defective parts.
Product Ordering Options
Model Number
Feature Option Details
HSN-1000 X
Package
Base Product
Nomenclature
L = Dual In-line Package (DIP)
F = Flat Pack
Nuclear Event Detector