COOLING FAN 2019 Recommendations Featuring New Products NEW DC Splash Proof Fan 9WL type The series lineup of the Splash Proof Fan has been expanded. Its IP68-rated water and dust protection ensures stable fan operation even in harsh environments. It offers ideal cooling solutions for PV inverters, rapid EV charging stations, and 92 x 92 x 38 mm digital signage. 140 x 140 x 51 mm pp. 318 to 321 140 x 140 x 38 mm pp. 313 to 317 pp. 299 to 301 NEW DC Long Life Fan 9LG type, 9CRLA type The series lineup of the Long Life Fan has been expanded. It offers ideal cooling solutions for communications equipment, industrial inverters, fuel cells, digital signage, servers, and routers. 60 x 60 x 76 mm pp. 373 to 374 DC 140 x 140 x 51 mm pp. 403 to 406 140 x 140 x 38 mm pp. 398 to 402 Low Power Consumption Fan 9GA type The series lineup has been expanded with a new model featuring even lower power consumption than our current model*. It is suitable for use in medical equipment, electrical measuring instruments, PV inverters, industrial inverters, LCDs, and arcade amusement machines. * 120x120x25 mm San Ace 120 9GV type. DC 120 x120 x 25 mm pp. 166 to 169 Counter Rotating Fan 9CRH type The series lineup has been enriched with a new model featuring higher static pressure than our current model*. It offers ideal cooling solutions for servers, power supplies, ICT devices, and data storage systems. * 40 x 40 x 56 mm San Ace 40 9CRV type. 2 40 x 40 x 56 mm pp. 229 to 230 A wide variety of products are available in various features. See the following pages to find out more. NEW DC Splash Proof Centrifugal Fan 9W2T type The series lineup of the Splash Proof Centrifugal Fan has been expanded. Its IP56-rated water and dust protection ensures stable fan operation even in harsh environments. It is suitable for outdoor ICT equipment, PV inverters, commercial refrigerators, air conditioning o175 x 69 mm equipment, and dust collectors. pp. 336 to 337 DC Centrifugal Fan 9T type, 9B1T type Centrifugal fans blow air in a centrifugal course. It is suitable for use in ICT equipment, large-scale inverters, refrigeration units, dust collectors, and air conditioners. A Centrifugal Fan has been integrated with an inlet nozzle and brackets into a Bracket-mounted Centrifugal Fan, making the installation work to your device easy. o 175 x 69 mm pp. 438 to 442 AC Bracket-mounted Centrifugal Fan 270 x 270 x 99 mm pp. 448 to 450 ACDC Fan 9AD type These fan operates by internally converting AC power into DC power. It provides the superior performance of a DC fan with the flexibility of AC input. 92 x92 x 38 mm pp. 476 to 478 Airflow Tester 120 x 120 x 38 mm pp. 479 to 481 pp. 524 to 529 This is a portable measuring device that enables you to easily measure the system impedance and operating airfow of devices. With connection duct mounted PWM Controller pp. 518 to 523 This device provides external speed control of PWM control function fans. By using this product, PWM control function fans can be fully utilized without the need for preparing new circuits, contributing to reducing the system power consumption and the fan noise. Box type PCB type 3 CONTENTS Domain Diagram..................... 6 to 9 DC 11 DC Fan 36 mm sq. ........................... 12 to 13 38 mm sq. ........................... 14 to 18 40 mm sq. ........................... 19 to 49 52 mm sq. ........................... 50 to 56 60 mm sq. ........................... 57 to 94 70 mm sq. ........................... 95 to 96 80 mm sq. ...........................97 to 141 92 mm sq. ........................ 142 to 165 120 mm sq. ..................... 166 to 189 127 mm sq. ..................... 190 to 194 140 mm sq. ..................... 195 to 200 150 mm sq. ..................... 201 to 202 o172 mm ........................ 203 to 218 o200 mm ........................ 219 to 222 Counter Rotating Fan 223 38 mm sq. ........................ 40 mm sq. ........................ 60 mm sq. ........................ 80 mm sq. ........................ 92 mm sq. ........................ 120 mm sq. ..................... o172 mm ........................ 224 to 225 226 to 237 238 to 246 247 to 253 254 to 255 256 to 257 258 to 259 Reversible Flow Fan 261 o92 mm ........................... 262 to 263 o136 mm ........................ 264 to 265 Splash Proof Fan 40 mm sq. ........................ 60 mm sq. ........................ 80 mm sq. ........................ 92 mm sq. ........................ 120 mm sq. ..................... 140 mm sq. ..................... o172 mm ........................ 267 268 to 272 273 to 278 279 to 288 289 to 303 304 to 312 313 to 321 322 to 327 Splash Proof Centrifugal Fan 329 o100 mm mm o150 mm o175 mm o133 4 ........................ 330 to 331 ........................ 332 to 333 ........................ 334 to 335 ........................ 336 to 339 DC o221 mm ........................ 340 to 341 o225 mm ........................ 342 to 343 Oil Proof Fan 40 mm sq. ........................ 60 mm sq. ........................ 80 mm sq. ........................ 92 mm sq. ........................ 120 mm sq. ..................... Long Life Fan 40 mm sq. ........................ 60 mm sq. ........................ 80 mm sq. ........................ 92 mm sq. ........................ 120 mm sq. ..................... 140 mm sq. ..................... o172 mm ........................ 345 346 to 349 350 to 355 356 to 357 358 to 361 362 to 363 365 366 to 367 368 to 376 377 to 382 383 to 389 390 to 397 398 to 406 407 to 410 Wide Temperature Range Fan 411 40 mm sq. ........................ 60 mm sq. ........................ 80 mm sq. ........................ 92 mm sq. ........................ 120 mm sq. ..................... G Proof Fan 412 to 413 414 to 415 416 to 417 418 to 421 422 to 423 425 120 mm sq. ..................... 426 to 427 o172 mm ........................ 428 to 429 Centrifugal Fan o100 mm ........................ mm ........................ o150 mm ........................ o175 mm ........................ o221 mm ........................ o225 mm ........................ 270 mm sq. ..................... o133 Blower 52 mm.............................. 76 mm.............................. 97 mm.............................. 120 mm ........................... 127 mm ........................... 160 mm ........................... 431 432 to 433 434 to 435 436 to 437 438 to 442 443 to 445 446 to 447 448 to 452 453 454 to 455 456 to 459 460 to 468 469 to 470 471 to 472 473 to 474 DC Fan AC 475 ACDC Fan 92 mm sq. ........................ 476 to 478 120 mm sq. ..................... 479 to 481 483 AC Fan 60 mm sq. ........................ 80 mm sq. ........................ 92 mm sq. ........................ 120 mm sq. ..................... 160 mm sq. ..................... o172 mm ........................ 484 to 487 488 to 495 496 to 499 500 to 508 509 to 511 512 to 516 PWM Controller 518 to 523 Airflow Tester 524 to 529 Options .................................... 530 to 544 Technical Material Overview and Characteristics of Fan ...... 545 Motor protection function ..................... 547 Guideline in Selecting a Fan..................... 548 Specifications for DC Fan Sensors ... 549 to 550 Specifications for AC Fan Sensor ............ 550 Fans with PWM Control Function ... 551 to 552 Splash Proof Fan .................................... 553 Cautions for Use of a Cooling Fan in the Vicinity of a Power Switching Circuit ...... 554 Standards and Certifications Safety Standards .................................... 555 RoHS Directive .................................... 556 Eco-products ....................................... 556 Please Read: Operating Precautions ........................... 557 Fan Mounting Using Self-tapping Screw ... 558 Safety Precautions ........................ 559 to 560 Index by Model No./Safety Standards List DC Fan ....................................... 561 to 581 ACDC Fan ............................................. 582 AC Fan ....................................... 582 to 583 Option .......................................... 584 to 585 Deleted Models in this Catalog ... 586 to 587 Distributors .............................. 588 to 593 Sale Notice of Cooling Fan Set Models ... 594 Counter Rotating Fan Reversible Flow Fan Splash Proof Fan Splash Proof Centrifugal Fan Oil Proof Fan Long Life Fan Wide Temperature Range Fan G Proof Fan Centrifugal Fan Blower ACDC Fan AC Fan PWM Controller Airflow Tester Options Technical Material Standards and Certifications Please Read Index by Model No./Safety Standards List Deleted Models in this Catalog Distributors Sale Notice of Cooling Fan Set Models 5 Domain Diagram DC Fan DC Airflow (m3/min) Frame size 0.1 0.2 36 mm sq. 38 mm sq. 40 mm sq. 52 mm sq. 60 mm sq. 70 mm sq. 80 mm sq. 92 mm sq. 120 mm sq. 127 mm sq. 140 mm sq. 150 mm sq. o 172 mm o 200 mm Airflow (CFM) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 20 30 40 page 12 to 13 Conversion table 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s 14 to 18 1 CFM=0.472 /s 1 /s=0.06 m3/min Thick (mm) 19 to 49 50 to 56 57 to 94 95 to 96 97 to 141 142 to 165 166 to 189 190 to 194 195 to 200 201 to 202 203 to 218 219 to 222 5 10 15 20 25 30 35 50 100 150 200 250 300 350 500 1000 1500 Counter Rotating Fan Frame size Airflow (m3/min) 0.1 0.2 38 mm sq. 40 mm sq. 60 mm sq. 80 mm sq. 92 mm sq. 120 mm sq. o 172 mm Airflow (CFM) 6 DC 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 page 9.0 10 224 to 225 Conversion table 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m /min 3 1 m3/min=16.67 /s 226 to 237 1 CFM=0.472 /s 1 /s=0.06 m3/min Thick (mm) 238 to 246 247 to 253 254 to 255 256 to 257 258 to 259 5 10 15 20 25 30 35 50 100 150 200 250 300 350 500 Reversible Flow Fan Frame size DC Airflow (m3/min) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 o 92 mm 7.0 8.0 page Conversion table 262 to 263 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s 1 CFM=0.472 /s o 136 mm 1 /s=0.06 m3/min 264 to 265 Thick (mm) Airflow (CFM) 5 10 15 20 25 30 35 50 100 150 200 250 300 Splash Proof Fan Frame size DC Airflow (m3/min) 0.1 0.2 40 mm sq. 60 mm sq. 80 mm sq. 92 mm sq. 120 mm sq. 140 mm sq. o 172 mm 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 page 9.0 10 268 to 272 Conversion table 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 273 to 278 1 m3/min=16.67 /s 1 CFM=0.472 /s 1 /s=0.06 m3/min 279 to 288 Thick (mm) 289 to 303 304 to 312 313 to 321 322 to 327 Airflow (CFM) 5 10 15 20 25 30 35 50 100 150 200 250 300 350 20 30 500 Splash Proof Centrifugal Fan Airflow (m3/min) Size 0.1 o 100 mm o 133 mm o 150 mm o 0.2 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 page 40 330 to 331 Conversion table 1 m3/min=35.31 (CFM) 332 to 333 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s 1 CFM=0.472 /s 1 /s=0.06 m3/min 175 mm o 221 mm o 225 mm Airflow (CFM) DC 0.3 334 to 335 Thick (mm) 336 to 339 340 to 341 342 to 343 5 10 15 20 25 30 35 50 100 150 200 250 300 350 500 1000 1500 Oil Proof Fan Frame size DC Airflow (m3/min) 0.1 0.2 40 mm sq. 60 mm sq. 80 mm sq. 92 mm sq. 120 mm sq. Airflow (CFM) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 page 305 to 349 346 306 Conversion table 1 m3/min=35.31 (CFM) 307 to 355 350 309 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s 1 CFM=0.472 /s 310 to 357 356 1 /s=0.06 m3/min Thick (mm) 311 to 361 358 314 315 to 363 362 316 5 10 15 20 25 30 35 50 100 150 200 250 300 7 Domain Diagram Long Life Fan Frame size DC Airflow (m3/min) 0.1 0.2 40 mm sq. 60 mm sq. 80 mm sq. 92 mm sq. 120 mm sq. 140 mm sq. o 172 mm Airflow (CFM) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 20 30 page 40 366 to 367 Conversion table 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 368 to 376 1 m3/min=16.67 /s 1 CFM=0.472 /s 1 /s=0.06 m3/min 377 to 382 Thick (mm) 383 to 389 390 to 397 398 to 406 407 to 410 5 10 15 20 25 30 35 50 100 150 200 250 300 350 1000 500 1500 Wide Temperature Range Fan Frame size Airflow (m3/min) 0.1 0.2 40 mm sq. 60 mm sq. 80 mm sq. 92 mm sq. 120 mm sq. Airflow (CFM) DC 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 page 412 to 413 Conversion table 1 m3/min=35.31 (CFM) 414 to 415 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s 1 CFM=0.472 /s 416 to 417 1 /s=0.06 m3/min Thick (mm) 418 to 421 422 to 423 5 10 15 20 25 0.7 0.8 0.9 1.0 30 50 35 100 150 200 250 300 G Proof Fan Frame size DC Airflow (m3/min) 0.1 120 mm sq 0.2 0.3 0.4 0.5 0.6 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 20 30 40 page Conversion table 426 to 427 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s o 172 mm Airflow (CFM) 1 CFM=0.472 /s 1 /s=0.06 m3/min 428 to 429 Thick (mm) 5 10 15 20 25 30 35 50 100 150 200 250 300 350 1000 500 1500 Centrifugal Fan Size o 0.1 100 mm o 133 mm o 150 mm o 175 mm o 221 mm o 225 mm 270 mm sq. Airflow (CFM) 8 DC Airflow (m3/min) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 20 30 40 page 432 to 433 Conversion table 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m /min 3 1 m3/min=16.67 /s 434 to 435 1 CFM=0.472 /s 1 /s=0.06 m3/min Thick (mm) 436 to 437 438 to 442 443 to 445 446 to 447 448 to 452 5 10 15 20 25 30 35 50 100 150 200 250 300 350 500 1000 1500 Blower Frame size DC Airflow (m3/min) 52 mm 76 mm 97 mm 120 mm 127 mm 160 mm 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 454 to 455 456 to 459 460 to 468 Conversion table 1 m3/min=35.31 (CFM) 469 to 470 1 CFM=0.0283 m3/min 1 m3/min=16.67 /s 1 CFM=0.472 /s 471 to 472 1 /s=0.06 m3/min Thick (mm) Airflow (CFM) 473 to 474 5 10 15 20 25 30 35 5.0 6.0 50 ACDC Fan Frame size page AC Airflow (m3/min) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 7.0 8.0 9.0 10 92 mm sq. 20 30 40 50 page Conversion table 476 to 478 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 1 m /min=16.67 /s 3 1 CFM=0.472 /s 120 mm sq. Airflow (CFM) 1 /s=0.06 m3/min 479 to 481 Thick (mm) 5 10 15 20 25 30 35 50 100 150 200 250 300 350 500 1000 1500 AC Fan Frame size AC Airflow (m3/min) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0 60 mm sq. 6.0 7.0 page 8.0 Conversion table 484 to 487 1 m3/min=35.31 (CFM) 1 CFM=0.0283 m3/min 1 m /min=16.67 /s 3 1 CFM=0.472 /s 80 mm sq. 1 /s=0.06 m3/min 488 to 495 Thick (mm) 92 mm sq. 496 to 499 120 mm sq. 500 to 508 160 mm sq. 509 to 511 o 172 mm Airflow (CFM) 512 to 516 5 10 15 20 25 30 35 50 100 150 200 250 300 9 10 DC Fan DC DC Fan Wide lineup including low power consumption fans (9GA type), silent fans (9S type), and high airflow and high static pressure fans. Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 9GV 12 12 J 1 01 1 Type name Frame size Voltage Speed code Frame thickness Sensor specifications Frame form Fans with PWM control function 9GV 12 12 P 4 G Type name Frame size Voltage PWM control function Frame thickness Speed code Type name 9E 9P Frame size (mm) 03 04 9R 9A 05 9EC 06 9G 08 01 Individual customer s spec (2 to 4 digits) 9GA 9GAX 9GV 09 12 13 9GE 14 9GX 9HV 9HVA 15 17 38 x 38 40 x 40 52 x 52 60 x 60 80 x 80 92 x 92 120 x 120 127 x 127 140 x 140 150 x 150 Voltage (V) 05 5 Speed code A B Frame thickness (mm) 0 70 Sensor specifications Frame form 12 12 24 24 C D 1 38 48 48 E Frame form 36 36 x 36 o 172 9S 47 9SG 57 20 o 172 x 147 o 172 x 150 o 200 (sidecut) (sidecut) etc. F 2 32 G H 3 28 J 4 25 K L M S W etc. 5 50, 51 6 20 7 15 9 10 01 or 001 02 or 002 D01 or D001 With a pulse sensor Without a sensor With a lock sensor Nil 1 Plastic frame: Ribbed frame Aluminum frame: Ribless frame Plastic frame: Ribless frame 3 40 x 40 x 28 mm for 1U applications Plastic frame: Ribbed frame How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 11 DC Fan 36x36x28 mm San Ace 36 9GX/9GV type (Model no.: 9GX3612P3K001 only) / General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 +70C (Non-condensing, Model no.: 9GX3612P3K001 only), -20 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 46 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 12 9GX3612P3K001 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.3 0.07 15.6 0.84 24000 3200 0.69 0.09 24.4 3.2 838 14.0 [inchHO] 3.367 0.056 SPL Operating temperature [dB (A)] [C] [h] -10 to +60 40000/60C (70000/40C) 66 32 Expected life * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Without sensor The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9GV3612J301 9GV3612G301 12 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 7.0 to 13.2 0.75 0.34 9.0 4.08 19000 14000 0.55 0.4 19.4 14.1 525 275 [V] [inchHO] 2.108 1.104 SPL Operating temperature Expected life [dB (A)] [C] [h] 58.5 52.0 -20 to +60 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor PWM control Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Static pressure (inch H2O) (Pa) 0 12 12 VDC DC12 V 4.0 1000 3.5 900 800 PWM PWM duty cycle 3.0 100% 700 2.5 600 2.0 500 1.5 400 50% 300 1.0 200 0.5 100 0% 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 20 Airflow 25 (CFM) (inch H2O) (Pa) PWM duty - Speed characteristics example 0 (min-1) PWM duty cycle 100% PWM100% 4.0 1000 3.5 900 13.2 V 800 3.0 700 12 V 2.5 600 10.8 V 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 20 Airflow 25 (CFM) 25000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 24000 min-1 20000 Fan speed PWM duty cycle Static pressure 9GX3612P3K001 15000 10000 5000 0 3200 min-1 100 (%) PWM duty cycle PWM 9GV3612G301 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 700 2.0 1.5 1.0 0.5 0 1.5 13.2 V 600 12 V 500 Static pressure Static pressure 2.5 With pulse sensor DC Fan 36 mm sq. 9GV3612J301 DC Airflow - Static Pressure Characteristics 7V 400 300 200 400 13.2 V 300 12 V 1.0 200 0.5 7V 100 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) Dimensions (unit: mm) 0 0.1 0.2 0 5 0.3 10 Airflow 0.4 0.5 15 (m3/min) 20 (CFM) (With pulse sensor) 360.5 29.50.3 4-o3.50.3 Mounting hole 280.5 Lead wire AWG28 UL 1007 (4) (4) 360.5 29.50.3 +30 320 0 (10) Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o3.7 29.50.3 35 o3 6. 8 29.50.3 35 Options Finger guards page: p. 532 Model no.: 109-1050 13 DC Fan 38x38x28 mm San Ace 38 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 52 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GA0312P3K001 12 9GA0312P3J001 10.8 to 13.2 9GA0312P3G001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.62 0.06 0.52 0.06 0.33 0.06 7.4 0.7 6.2 0.7 4.0 0.7 25000 3000 23500 3000 19000 3000 0.6 0.07 0.57 0.07 0.45 0.07 21.2 2.5 20.1 2.5 15.9 2.5 800 11 720 11 460 11 [inchHO] 3.21 0.04 2.89 0.04 1.85 0.04 SPL Operating temperature Expected life [dB (A)] [C] [h] 59.0 15.0 57.5 15.0 53.0 15.0 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 570. Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Static pressure (inch H2O) (Pa) PWM PWM duty cycle 100% 1.5 400 50% 300 1.0 200 0.5 100 0% 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 14 DC12 V 12 VDC 3.5 900 800 3.0 700 2.5 600 2.0 500 5 10 15 Airflow 20 25 (CFM) (inch H2O) (Pa) Static pressure PWM duty cycle 4.0 1000 3.5 900 800 3.0 700 2.5 600 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 25000 12 V 10.8 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 10 15 Airflow 25000 min-1 15000 10000 5000 5 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 20000 13.2 V Fan speed 9GA0312P3K001 20 25 (CFM) 0 3000 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 600 2.0 500 1.5 400 1.0 0.5 0 300 50% 200 100 0 0 0% 0.1 0.2 0.3 0.4 0.5 0.6 0.7 5 10 15 Airflow 9GA0312P3G001 20 25 (CFM) Static pressure Static pressure PWM PWM duty cycle 100% 300 0 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 50% 0% 0.1 0.2 5 10000 Airflow 3000 min-1 100 (%) 0 PWM duty cycle PWM 25 (CFM) 20 0.3 10 Airflow 0.4 2.0 500 1.5 0.5 0 0.5 (m3/min) 15 Dimensions (unit: mm) 12 V 10.8 V 19000 min-1 10000 5000 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15000 200 0 (CFM) (min-1) 20000 13.2 V 400 300 1.0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 600 1.0 0.5 15000 5000 (inch H2O) (Pa) 12 VDC DC12 V 2.0 500 200 0 10.8 V Operating voltage range (inch H2O) (Pa) 400 12 V With pulse sensor with PWM control function PWM duty cycle 1.5 0 23500 min-1 20000 1.5 400 300 1.0 200 0.5 100 (m3/min) 25000 13.2 V 2.0 500 Voltage: 12 VDC DC12 V frequency: kHz 25 kHz PWM25 (min-1) PWM PWM duty cycle 100% PWM100% 3.5 900 800 3.0 700 2.5 600 Fan speed 2.5 PWM PWM duty cycle 100% 700 Static pressure Static pressure 3.0 (inch H2O) (Pa) 12 VDC DC12 V 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 3000 min-1 0.1 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) 0 100 (%) PWM duty cycle PWM (CFM) (With ribs) 4-o3.50.3 Mounting hole 300.3 380.5 +30 320 0 (10) Lead wire 300.3 380.5 Rotating direction AWG26 UL 1007 (4) (4) 280.5 Airflow direction 15 DC Fan 38 mm sq. 9GA0312P3J001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 37 300.3 37 (16) 37 .5 300.3 4-o3.7 (16) Options Finger guards Model no.: 109-1065 16 page: p. 532 DC DC Fan DC Fan 38 mm sq. 38x38x28 mm San Ace 38 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -20 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 50 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9GV0312K301 9GV0312J301 9GV0312G301 9GV0312E301 9GV0312H301 [V] 7 to 13.2 12 4.5 to 13.2 [A] [W] 0.79 0.6 0.4 0.21 0.16 9.48 7.2 4.8 2.52 1.92 Rated speed Max. airflow Max. static pressure [min-1] [m/min] [CFM] [Pa] 18200 15900 13500 10500 7000 0.65 0.57 0.48 0.37 0.24 23 20 17 13.1 8.5 425 315 220 130 60 SPL [inchHO] Operating temperature Expected iife [dB (A)] [C] [h] 59 54 50 43 34 -20 to +60 40000/60C 1.707 1.265 0.924 0.522 0.241 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 573 to 574. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9GV0312K301 With pulse sensor Operating voltage range 0.5 0 0 (inch H2O) (Pa) 12 V 7V 1.5 350 400 13.2 V 350 12 V 300 1.0 250 7V 200 0.5 1.25 Static pressure 1.0 13.2 V 150 100 50 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) (CFM) 0 5 10 15 20 25 Airflow 0 With pulse sensor Operating voltage range 450 Static pressure Static pressure 1.5 500 450 400 350 300 250 200 150 100 50 9GV0312G301 With pulse sensor (inch H2O) (Pa) (inch H2O) (Pa) 2.0 9GV0312J301 Operating voltage range 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 (CFM) 1.00 0.75 0.50 0.25 0 300 13.2 V 250 12 V 200 7V 150 100 50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 17 Airflow - Static Pressure Characteristics 9GV0312E301 9GV0312H301 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 200 Static pressure 0.7 0.6 13.2 V 150 12 V 0.5 0.4 Static pressure 0.8 100 0.3 0.2 50 4.5 V 0.1 0 With pulse sensor 0 0.1 0 0.2 5 0.3 0.4 10 (m3/min) 15 Airflow Dimensions (unit: mm) 0.5 125 0.4 100 0.3 75 0.2 50 0.1 25 0 0 13.2 V 12 V 4.5 V 0.05 0.10 0.15 0.20 0.25 0.30 (m3/min) 0 (CFM) 2 4 6 Airflow 8 10 (CFM) (With ribs) 380.5 280.5 300.3 4-o3.50.3 Mounting hole (4) (4) 300.3 380.5 +30 320 0 (10) Lead wire AWG26 UL 1007 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 37 300.3 37 (16) .5 37 300.3 4-o3.7 (16) Options Finger guards Model no.: 109-1065 18 page: p. 532 DC DC Fan DC Fan 40 mm sq. 40x40x10 mm San Ace 40 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 19 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0405H901 109P0405M901 109P0412H901 109P0412M901 [V] 5 4.5 to 5.5 12 7 to 13.8 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.16 0.11 0.07 0.06 0.8 0.55 0.84 0.72 6200 5000 6200 5000 0.15 0.12 0.15 0.12 5.3 4.2 5.3 4.2 41.2 27 41.2 27 SPL [inchHO] Operating temperature Expected iife [dB (A)] [C] [h] 25 21 25 21 -10 to +60 40000/60C 0.165 0.108 0.165 0.108 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on pp. 562 to 563. PWM control Airflow - Static Pressure Characteristics 109P0405H901 109P0405M901 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.10 5V 4.5 V 30 20 0.05 0 (inch H2O) (Pa) 10 0 0.05 0 1 2 0.10 0.15 3 5 4 Airflow 0.20 (m3/min) 6 7 (CFM) 0.15 0.25 50 5.5 V 40 5V 30 0.10 4.5 V 20 0.05 0 Static pressure 0.15 40 5.5 V Static pressure Static pressure 50 0.20 With pulse sensor Operating voltage range (inch H2O) (Pa) 60 0.20 109P0412H901 With pulse sensor 10 0 0.05 0 1 2 0.10 0.15 3 5 4 Airflow 0.20 (m3/min) 6 7 (CFM) 60 0.20 50 0.15 40 0.10 13.8 V 12 V 7V 30 20 0.05 0 10 0 0.05 0 1 2 0.10 0.15 3 5 4 Airflow 0.20 (m3/min) 6 7 (CFM) 19 Airflow - Static Pressure Characteristics 109P0412M901 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.20 50 Static pressure 13.8 V 0.15 40 12 V 30 7V 0.10 20 0.05 0 10 0 0.05 0 1 2 0.10 0.15 3 5 4 Airflow 0.20 (m3/min) 6 7 (CFM) Dimensions (unit: mm) +1 40 0 4-o3.50.3 Mounting hole 320.3 +1 10 0 (3) (3) 320.3 +1 40 0 +30 320 0 (10) Lead wire AWG26 UL 1007 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (15) .5 38 320.3 4-o3.7 (15) Options Finger guards Model no.: 109-059, 109-059H 20 page: p. 532 DC DC Fan DC Fan 40 mm sq. 40x40x15 mm San Ace 40 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 28 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 12 9GA0412P7G001 10.2 to 13.8 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 [min-1] [W] 0.17 2.04 Max. airflow [m/min] 13100 0.36 Max. static pressure [CFM] 12.7 [Pa] [inchHO] 192 0.77 SPL Operating temperature [dB (A)] [C] Expected life [h] 42 -20 to +70 40000/60C (70000/40C) SPL Operating temperature Expected life [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Lock sensor The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Model no. [V] 9GA0412G70 01 9GA0412H70 01 12 [V] [A] [W] [min-1] 7 to 13.8 0.17 0.06 2.04 0.72 13100 7300 Max. airflow [m/min] 0.36 0.2 [CFM] 12.7 7.1 Max. static pressure [Pa] 192 59.6 [inchHO] 0.77 0.24 42 28 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 570. PWM control Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) 12 VDC DC12 V Static pressure Static pressure (inch H2O) (Pa) PWM duty cycle PWM 100% 50% 0 0.2 0.1 0 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) (CFM) (min-1) PWM duty cycle 100% PWM100% 1.2 300 1.0 250 0.8 200 13.8 V 0.6 150 12 V 0.4 100 0.2 50 0 PWM duty - Speed characteristics example 15000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 13100 min-1 10.2 V 0 0.1 0 0.2 5 0.3 10 Airflow 0.4 0.5 (m3/min) (CFM) 15 Fan speed 9GA0412P7G001 PWM duty cycle 10000 5000 0 100 (%) PWM duty cycle PWM 21 Airflow - Static Pressure Characteristics 9GA0412G7001 9GA0412H7001 With pulse sensor Operating voltage range (inch H2O) (Pa) 12 VDC DC12 V 1.2 300 1.0 250 0.8 200 13.8 V 0.6 150 12 V 0.4 100 0.2 50 0 Operating voltage range 0.4 Static pressure Static pressure (inch H2O) (Pa) 7V 0 0.1 0 0.2 5 0.3 10 Airflow With pulse sensor 0.3 0.2 0.1 0 0.5 (m3/min) 0.4 15 13.8 V 12 V 7V 0 0 (CFM) Dimensions (unit: mm) 12 VDC DC12 V 100 90 80 70 60 50 40 30 20 10 0.05 0.1 0.15 0.2 0.25 (m3/min) (CFM) 2 4 6 8 Airflow (With pulse sensor with PWM control function) 4-o3.50.3 Mounting hole (4) 15.20.5 (4) 320.3 400.3 +30 320 0 (10) Lead wire AWG28 UL 1007 320.3 400.3 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side (17.6) 39 4-o3.7 40 (17.6) 320.3 39 320.3 Options Finger guards Model no.: 109-059, 109-059H 22 page: p. 532 DC DC Fan DC Fan 40 mm sq. 40x40x15 mm San Ace 40 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 32 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0405H701 109P0405M701 109P0412R701 109P0412S701 109P0412H701 109P0412M701 109P0424H701 5 4.5 to 5.5 7 to 13.8 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.28 0.21 0.13 0.18 0.13 0.095 0.08 1.4 1.05 1.56 2.16 1.56 1.14 1.92 7700 6500 9700 8600 7700 6500 7700 0.18 0.15 0.227 0.2 0.18 0.15 0.18 6.4 5.3 8.0 7.06 6.4 5.3 6.4 75.5 52.9 111.9 92.1 75.5 52.9 75.5 [V] SPL [inchHO] Operating temperature Expected iife [dB (A)] [C] 28 24 34 32 28 24 28 -20 to +60 0.303 0.213 0.449 0.369 0.303 0.213 0.303 [h] 60000/60C 40000/60C -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P0405M701 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.6 150 80 0.30 5.5 V 0.4 100 5V 0.3 0.2 Static pressure Static pressure (inch H2O) (Pa) 0.5 4.5 V 50 0.1 0 109P0412R701 With pulse sensor 0.25 (inch H2O) (Pa) 0.8 0.10 5.5 V 5V 40 4.5 V 20 0.05 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0 200 0.7 60 0.20 0.15 With pulse sensor Operating voltage range Static pressure 109P0405H701 0.6 150 0.5 0.4 13.8 V 100 12 V 0.3 0.2 50 7V 0.1 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0 0 0 0.1 2 4 0.2 6 Airflow 8 0.3 (m3/min) 10 (CFM) 23 Airflow - Static Pressure Characteristics 109P0412S701 109P0412H701 With pulse sensor Operating voltage range Operating voltage range 0.5 0.4 13.8 V 100 12 V 0.3 0.2 10.2 V 50 0.1 0 (inch H2O) (Pa) 150 0.30 0.5 0.4 13.8 V Static pressure 0.6 Static pressure Static pressure 150 100 12 V 0.3 0.2 10.2 V 50 0.1 0 0.1 0 109P0424H701 2 0.2 4 6 Airflow 0 0.3 (m3/min) 8 10 0 0.1 2 0.2 4 6 Airflow 0.3 (m3/min) 8 10 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.6 150 0.5 0.4 27.6 V 100 24 V 0.3 0.2 20.4 V 50 0.1 0 0 0.1 0 2 0.2 4 6 Airflow 0.3 (m3/min) 8 10 (CFM) Dimensions (unit: mm) +1 40 0 320.3 4-o3.50.3 Mounting hole +1 15 0 (4) (4) 320.3 +1 40 0 +30 320 0 (10) Lead wire AWG24 UL 1007 Rotating direction 24 0.25 80 13.8 V 60 0.20 0.15 0.10 12 V 40 10.2 V 20 0.05 0 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.6 109P0412M701 With pulse sensor Airflow direction (CFM) 0 0 0.1 0 2 4 0.3 (m3/min) 0.2 6 Airflow 8 10 (CFM) DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 39 320.3 39 (15) .5 320.3 4-o3.7 (15) 38 DC Fan 40 mm sq. Inlet side, Outlet side Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 25 DC Fan 40x40x20 mm San Ace 40 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 35 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9GA0405P6H001** 9GA0405P6F001** [V] 5 4.5 to 5.5 9GA0412P6G001 12 9GA0412P6H001 10.2 to 13.8 9GA0412P6F001 9GA0424P6G001** 9GA0424P6H001** 9GA0424P6F001** 24 * PWM frequency: 25 kHz 20.4 to 27.6 PWM duty cycle* [%] 100 100 100 0 100 0 100 0 100 100 100 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.35 0.18 0.23 0.04 0.14 0.04 0.08 0.03 0.13 0.08 0.04 1.75 0.9 2.76 0.48 1.68 0.48 0.96 0.36 3.12 1.92 0.96 12400 8000 16000 3800 12400 3800 8000 2200 16000 12400 8000 0.33 0.21 0.42 0.1 0.33 0.1 0.21 0.06 0.42 0.33 0.21 11.7 7.4 14.8 3.5 11.7 3.5 7.4 2.1 14.8 11.7 7.4 191 79.5 318 17.9 191 17.9 79.5 6.0 318 191 79.5 [inchHO] 0.77 0.32 1.28 0.07 0.77 0.07 0.32 0.02 1.28 0.77 0.32 SPL Operating temperature [dB (A)] [C] 40 28 47 14 40 14 28 10 47 40 28 Expected life [h] 40000/60C 60000/60C 40000/60C -20 to +70 60000/60C 40000/60C 60000/60C ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 570. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0405P6H001 With pulse sensor with PWM control function Operating voltage range 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 0 PWM duty cycle PWM 100% 50% 50 0 0.1 0 26 (inch H2O) (Pa) 5 VDC DC5 V 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) Static pressure Static pressure (inch H2O) (Pa) 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 14000 12000 Fan speed PWM duty cycle 5.5 V 5V 4.5 V Voltage: 5 VDC DC5 V PWM frequency:kHz 25 kHz PWM25 12400 min-1 10000 8000 6000 4000 2000 0 0.1 0 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.4 0.3 0.2 0.1 Static pressure 0.4 100 80 PWM duty cycle PWM 60 100% 40 50% 20 0 0 0.1 4 2 0.2 6 Airflow 9GA0412P6G001 40 4.5 V 20 10000 400 6000 4000 0 0.1 2 0.2 4 6 Airflow 8 10 PWM duty cycle PWM (CFM) 1.6 400 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 16000 1.4 350 1.2 300 1.0 250 1.0 250 0.8 200 0.8 200 0.6 150 0.6 150 0.4 100 0.4 100 4000 0.2 50 0% 0.2 50 2000 0 0.1 0 0 100% 50% 0.2 0.3 0.4 10 0.5 (m3/min) 15 Airflow 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) 12 VDC DC12 V PWM duty cycle PWM 100% 50% 0% 0 0 2 0.1 4 9GA0412P6F001 6 0.2 8 0.3 0.4 (m3/min) 10 12 14 (CFM) 120 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 PWM duty cycle PWM 100% 40 50% 0% 0 0.1 0 2 (min-1) 16000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 13.8 V 12400 min-1 12000 12 V 10.2 V 10000 8000 6000 4000 3800 min-1 2000 0.1 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow 100 (%) 0 PWM duty cycle PWM (CFM) 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0.3 0.2 0.1 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 120 0.4 20 PWM duty cycle 100% PWM100% 0 Static pressure 0.1 300 (inch H2O) (Pa) 0.4 100 60 100 (%) PWM duty - Speed characteristics example Operating voltage range 12 VDC DC12 V 80 3800 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0.2 1.2 Airflow PWM duty cycle 0.3 Airflow 6000 PWM duty cycle PWM (CFM) Fan speed 200 15 8000 0 0.4 0.5 (m3/min) 16000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 100 12000 13.8 V 80 Fan speed 0.8 0.3 10 Operating voltage range 300 250 0.2 5 10000 With pulse sensor with PWM control function (inch H2O) (Pa) 1.0 10.2 V 0.1 16000 min-1 12000 12 V 0 (CFM) PWM duty cycle 1.2 13.8 V Fan speed PWM duty cycle PWM Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 350 300 9GA0412P6H001 100 (%) 0 0.3 (m3/min) 1.2 5 8000 min-1 8000 2000 (inch H2O) (Pa) Static pressure Static pressure 5V 60 0 12 VDC DC12 V 0 Static pressure 5.5 V 80 1.4 0 Voltage: 5 VDC DC5 V PWM frequency:kHz 25 kHz PWM25 12000 100 Operating voltage range (inch H2O) (Pa) Static pressure 0.1 14000 With pulse sensor with PWM control function PWM duty cycle 1.6 0.2 0 0.3 (m3/min) 10 (CFM) 8 0.3 (min-1) PWM duty cycle 100% PWM100% 120 Static pressure Static pressure (inch H2O) (Pa) 5DC5 VDC V 120 PWM duty - Speed characteristics example Fan speed PWM duty cycle 12 V 60 10.2 V 40 10000 8000 8000 min-1 6000 4000 20 -1 2000 2200 min 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0 100 (%) PWM duty cycle PWM 27 DC Fan 40 mm sq. 9GA0405P6F001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0424P6G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.4 350 1.2 300 1.0 250 PWM duty cycle PWM 100% 0.8 200 0.6 150 0.4 100 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 20 Airflow 9GA0424P6H001 Static pressure 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0.1 4 9GA0424P6F001 0.2 6 8 0.3 0.4 (m3/min) 40 50% 0.1 0 28 2 100 50 0 0 8000 6000 4000 2000 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 10 15 20 100 (%) 0 PWM duty cycle PWM (CFM) 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 16000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 14000 12400 min-1 12000 27.6 V 24 V 20.4 V 10000 8000 6000 4000 2000 0.1 2 4 0.2 6 0.3 8 0.4 (m3/min) 100 (%) 0 PWM duty cycle PWM 10 12 14 (CFM) Airflow 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0.4 0.3 0.2 0.1 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 120 PWM PWM duty cycle 100% 0 0.4 0.2 20.4 V 0 Static pressure Static pressure 0 150 (inch H2O) (Pa) 0.4 100 20 0.6 24 V Operating voltage range 120 0.1 200 10000 With pulse sensor with PWM control function 24 VDC DC24 V 60 0.8 Airflow (inch H2O) (Pa) 0.2 250 10 12 14 (CFM) PWM duty cycle 0.3 1.0 12000 27.6 V (inch H2O) (Pa) 50% 80 300 14000 Operating voltage range 100% 2 1.2 16000 min-1 Airflow PWM duty cycle PWM 0 350 5 24 VDC DC24 V 0 400 1.4 16000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 300 1.6 (CFM) PWM duty cycle 1.2 450 Fan speed 0 1.8 (min-1) PWM duty cycle 100% PWM100% 16000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 14000 100 27.6 V 12000 80 Fan speed 0 50% 50 Static pressure 0.2 Static pressure 1.8 450 1.6 400 Static pressure (inch H2O) (Pa) 24 VDC DC24 V PWM duty - Speed characteristics example Fan speed PWM duty cycle 24 V 60 20.4 V 40 10000 8000 8000 min-1 6000 4000 20 2000 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0 100 (%) PWM duty cycle PWM DC Dimensions (unit: mm) DC Fan 40 mm sq. 4-o3.50.3 Mounting hole (10) 320.3 400.3 +30 320 0 Lead wire AWG26 UL 1007 320.3 400.3 (4) (4) 200.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 4-o3.7 320.3 40 39 320.3 (17.6) Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 29 DC Fan 40x40x20 mm San Ace 40 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 45 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0405J601 109P0405H601 109P0405F601 109P0405M601 109P0412G601 109P0412D601 109P0412E601 109P0412H601 109P0412F601 109P0412M601 109P0424G601 109P0424D601 109P0424H601 109P0424F601 109P0424B601 5 12 24 [V] 4.5 to 5.5 7 8 12 12 12 14 20.4 to 13.8 to 13.8 to 27.6 to 27.6 to 27.6 to 27.6 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.46 0.32 0.25 0.12 0.28 0.18 0.13 0.11 0.09 0.06 0.15 0.13 0.07 0.06 0.06 2.3 1.6 1.25 0.6 3.36 2.16 1.56 1.32 1.08 0.72 3.6 3.12 1.68 1.44 1.44 9800 8000 6500 5000 12500 11000 9200 8000 6500 5000 12500 11000 8300 6500 5200 0.28 0.225 0.183 0.136 0.35 0.31 0.26 0.225 0.183 0.136 0.35 0.31 0.233 0.183 0.14 9.9 8.0 6.5 4.8 12.4 10.9 9.2 8.0 6.5 4.8 12.4 10.9 8.2 6.5 4.9 98.5 65.7 45.1 26.5 153.8 124 87.3 65.7 45.1 26.5 153.8 124 69.6 45.1 28.3 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.396 0.264 0.181 0.106 0.618 0.498 0.351 0.264 0.181 0.106 0.618 0.498 0.28 0.181 0.114 [C] 39 33 28 24 44 42 37 33 28 24 44 42 35 28 25 [h] 40000/60C -20 to +70 60000/60C 40000/60C -20 to +60 60000/60C -20 to +70 -20 to +60 40000/60C -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 562 to 563. Lock sensor Airflow - Static Pressure Characteristics 109P0405J601 109P0405H601 With pulse sensor Operating voltage range Operating voltage range 0.35 5.5 V 5V 4.5 V 0.1 0 30 (inch H2O) (Pa) 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 (CFM) Airflow 0.30 0.25 80 5.5 V 60 50 0.15 40 5V 4.5 V 30 20 0.05 10 0 0 60 5.5 V 0.20 70 0.20 0.10 0.25 90 Static pressure 130 120 110 100 90 80 70 60 50 40 30 20 10 0 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure Static pressure (inch H2O) (Pa) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 109P0405F601 With pulse sensor 0.2 0.1 0 2 4 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0.15 0.10 5V 40 4.5 V 20 0.05 0 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 109P0412G601 With pulse sensor Operating voltage range Operating voltage range 30 5.5 V 5V 4.5 V 0.100 0.075 0.050 0.025 0 20 10 0 0.10 0.05 1 2 3 0.15 4 5 Airflow 109P0412E601 6 7 0 0.2 0.1 0.2 0.3 0.4 0.4 12 V 40 7V 20 0 0.1 0 2 109P0412M601 0.2 4 6 0.3 Airflow 10 7V 60 40 20 0 0.1 13.8 V 80 12 V 7V 40 0 0.2 4 6 0.3 0.4 8 10 12 14 Airflow (m3/min) (CFM) With pulse sensor Operating voltage range 0.25 0.2 0.1 2 (inch H2O) (Pa) 20 0 0.1 0 2 109P0424G601 Operating voltage range 80 0 100 (CFM) With pulse sensor 0.3 109P0412F601 With pulse sensor 60 0.3 (m3/min) 8 12 V 120 100 0.2 13.8 V 140 Airflow 120 80 160 0.4 0 0.5 (m3/min) Operating voltage range 13.8 V 0.5 0.1 (inch H2O) (Pa) 100 0.6 180 0 2 4 6 8 10 12 14 16 18 (CFM) Static pressure Static pressure 0.1 0.3 7V 109P0412H601 With pulse sensor 60 0.2 0.4 13.8 V 12 V (CFM) (inch H2O) (Pa) 0.3 0.5 0 0.20 (m3/min) Operating voltage range 0.4 0.6 0.1 0 0.5 0.7 0.7 Static pressure 0.125 40 (inch H2O) (Pa) 220 200 180 160 140 120 100 80 60 40 20 0 Static pressure 0.150 0.8 Static pressure Static pressure 0.175 0.9 50 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.200 109P0412D601 With pulse sensor DC Fan 40 mm sq. 109P0405M601 DC Airflow - Static Pressure Characteristics 0.2 4 6 Airflow 8 10 13.8 V 0.20 0.15 0.10 12 V 40 7V 20 0.05 0 0.3 (m3/min) 60 0 0.1 0 (CFM) 2 109P0424D601 With pulse sensor Operating voltage range 0.2 4 6 0.3 (m3/min) 8 Airflow 10 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 40 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 13.8 V 30 12 V 0.100 0.075 0.050 20 8V 10 0.025 0 0 0.05 0 1 0.15 0.10 2 3 4 Airflow 109P0424H601 5 0.20 (m3/min) 6 7 0.25 80 Static pressure Static pressure 0.1 2 4 0.2 0.3 0.4 (m3/min) 6 8 10 12 14 (CFM) 27.6 V 24 V 12 V 40 20 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0.10 100 0.3 80 12 V 60 40 0.1 20 0 0 0.1 0 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 60 0.15 40 27.6 V 24 V 40 14 V 20 0.05 0 120 0.4 0.2 27.6 V 24 V 140 0.5 109P0424B601 With pulse sensor 0.20 0.15 160 Airflow Operating voltage range 100 0.2 0 12 V (inch H2O) (Pa) 60 0.1 24 V 109P0424F601 With pulse sensor (inch H2O) (Pa) 0.3 27.6 V 0 (CFM) Operating voltage range 0.4 0.6 Static pressure 0.125 Static pressure Static pressure 0.150 0.7 Static pressure (inch H2O) (Pa) 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 30 27.6 V 0.10 20 0.05 0 24 V 20.4 V 10 0 0.05 0 1 2 0.10 0.15 3 5 4 Airflow 0.20 (m3/min) 6 7 (CFM) 31 Dimensions (unit: mm) +1 40 0 4-o3.50.3 Mounting hole (4) Lead wire AWG24 UL 1007 320.3 200.5 (4) +1 40 0 320.3 +30 320 0 (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (15) .5 38 320.3 4-o3.7 (15) Options Finger guards Model no.: 109-059, 109-059H 32 page: p. 532 DC DC Fan DC Fan 40 mm sq. 40x40x28 mm San Ace 40 9HV type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 60 g Specifications The models listed below have pulse sensors with PWM control function. PWM duty cycle* [%] Rated voltage Operating voltage range Model no. [V] [V] 12 9HV0412P3K001 Rated current Rated input Rated speed 100 0 10.8 to 12.6 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.52 0.2 18.3 2.4 25000 7500 0.83 0.25 29.3 8.8 1100 99 [inchHO] 4.42 0.4 SPL Operating temperature Expected life [dB (A)] [C] [h] 65 37 -20 to +60 40000/60C * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV0412P3K001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 4.0 1000 3.0 2.0 1.0 0 1400 5.0 1200 PWM duty cycle PWM 100% Static pressure Static pressure 5.0 1200 (inch H2O) (Pa) 12 VDCV DC12 1400 800 600 50% 400 200 3.0 2.0 1.0 0% 800 (min-1) PWM duty cycle 100% PWM100% 30000 12 V 10.8 V 400 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 Airflow 25000 min-1 20000 15000 10000 5000 200 5 10 15 20 25 30 35 (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 25000 12.6 V 600 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 4.0 1000 PWM duty - Speed characteristics example Fan speed PWM duty cycle 5 10 15 20 25 30 35 (CFM) Airflow 0 7500 min-1 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 8-o3.50.3 Mounting hole 320.3 400.3 320 +30 0 (10) Lead wire 320.3 400.3 Rotating direction AWG26 UL 1007 40.3 280.5 40.3 Airflow direction 33 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 (17.5) 4-o3.7 (17.5) 2.8 o4 320.3 39 4-R2.85 Options Finger guards Model no.: 109-059, 109-059H 34 page: p. 532 DC DC Fan DC Fan 40 mm sq. 40x40x28 mm San Ace 40 9GAX type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 53 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GAX0412P3S001** 10.8 to 12.6 9GAX0412P3S003 12 9GAX0412P3K001** 10.8 to 13.2 9GAX0412P3K003 * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 0 100 20 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.3 0.07 1.3 0.11 0.92 0.07 0.92 0.1 15.6 0.84 15.6 1.32 11.04 0.84 11.04 1.2 25000 4400 25000 7800 22000 4200 22000 6500 0.9 0.155 0.9 0.26 0.81 0.15 0.81 0.24 31.8 5.5 31.8 9.2 28.6 5.3 28.6 8.5 1000 32 1000 87 800 28 800 70 [inchHO] 4.02 0.125 4.02 0.35 3.21 0.11 3.21 0.28 SPL Operating temperature Expected life [dB (A)] [C] [h] 64 21.5 64 38 61 21 61 32 -20 to +60 30000/60C ** Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Static pressure (inch H2O) (Pa) 12 VDC DC12 V 4.5 1100 1000 4.0 3.5 900 PWM PWM duty cycle 800 100% 3.0 700 2.5 600 2.0 500 1.5 400 300 1.0 200 20% 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 (CFM) Airflow (inch H2O) (Pa) Static pressure PWM duty cycle PWM duty cycle 100% PWM100% 4.5 1100 1000 4.0 3.5 900 12.6 V 800 3.0 12 V 700 2.5 600 10.8 V 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 PWM duty - Speed characteristics example 5 10 15 20 25 30 35 (CFM) Airflow (min-1) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 25000 Fan speed 9GAX0412P3S001 25000 min-1 20000 15000 10000 5000 0 4400 min-1 100 (%) PWM duty cycle PWM 35 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 5 10 15 20 25 30 35 (CFM) Airflow Static pressure (inch H2O) (Pa) 5 10 15 20 25 30 Airflow Static pressure 10000 7800 min-1 0 100 (%) PWM duty cycle PWM PWM duty cycle 100% PWM100% 5 10 15 20 25 30 Airflow (min-1) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 22000 min-1 20000 15000 10000 5000 4200 min-1 0 100 (%) PWM duty cycle PWM (CFM) With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 36 15000 PWM duty - Speed characteristics example 4.0 1000 3.5 900 13.2 V 800 3.0 700 12 V 2.5 600 2.0 500 10.8 V 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 (CFM) PWM duty cycle 12 VDC DC12 V 4.0 1000 3.5 900 800 3.0 700 PWM PWM duty cycle 2.5 600 100% 2.0 500 1.5 400 300 1.0 200 0% 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 5 20000 5000 Airflow (inch H2O) (Pa) 12 VDC DC12 V 4.0 1000 3.5 900 800 3.0 PWM duty cycle PWM 700 100% 2.5 600 2.0 500 1.5 400 300 1.0 200 20% 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 25000 min-1 25000 5 10 15 20 25 30 35 (CFM) Operating voltage range 9GAX0412P3K003 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 0 (min-1) Fan speed 9GAX0412P3K001 PWM duty cycle 100% PWM100% 4.5 1100 4.0 1000 3.5 900 12.6 V 800 3.0 12 V 700 2.5 600 10.8 V 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 Static pressure 0 (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed 12 VDC DC12 V 4.5 1100 4.0 1000 3.5 900 800 3.0 700 PWM PWM duty cycle 2.5 600 100% 2.0 500 1.5 400 300 1.0 200 0% 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 10 15 20 25 30 Airflow (CFM) (inch H2O) (Pa) Static pressure Static pressure (inch H2O) (Pa) Static pressure PWM duty cycle PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 4.0 1000 3.5 900 13.2 V 800 3.0 700 12 V 2.5 600 2.0 500 10.8 V 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 5 10 15 20 25 30 Airflow (CFM) (min-1) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 20000 Fan speed 9GAX0412P3S003 22000 min-1 15000 10000 5000 0 6500 min-1 100 (%) PWM duty cycle PWM Dimensions (unit: mm) DC (With ribs) DC Fan 40 mm sq. 4-o3.50.3 Mounting hole (10) 320.3 400.3 +30 320 0 Lead wire AWG26 UL 1007 320.3 (4) (4) 280.5 400.3 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 37 DC Fan 40x40x28 mm San Ace 40 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 53 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GA0412P3K01 9GA0412P3J01 12 9GA0412P3G01 10.8 to 13.2 9GA0412P3H01 9GA0412P3M01 9GA0424P3J001** 9GA0424P3G001** 9GA0424P3H001** 9GA0424P3M001** * PWM frequency: 25 kHz 24 21.6 to 26.4 PWM duty cycle* [%] 100 0 100 0 100 0 100 0 100 0 100 100 100 100 Rated current Rated input Rated speed [A] [W] 0.92 0.1 0.49 0.05 0.39 0.05 0.28 0.04 0.21 0.04 0.27 0.22 0.16 0.11 11.04 1.2 5.88 0.6 4.68 0.6 3.36 0.48 2.52 0.48 6.48 5.28 3.84 2.64 Max. airflow Max. static pressure [min-1] [m/min] [CFM] [Pa] 22000 6500 18000 4500 16500 4500 14500 3500 12500 3500 18000 16500 14500 12500 0.81 0.23 0.67 0.16 0.61 0.16 0.54 0.13 0.46 0.13 0.67 0.61 0.54 0.46 28.6 8.12 23.7 5.7 21.5 5.7 19.1 4.6 16.2 4.6 23.7 21.5 19.1 16.2 799 68 535 33 450 33 347 20 258 20 535 450 347 258 [inchHO] 3.21 0.27 2.15 0.13 1.81 0.13 1.39 0.08 1.04 0.08 2.15 1.81 1.39 1.04 SPL Operating temperature Expected life [dB (A)] [C] [h] -20 to +60 30000/60C -20 to +70 40000/60C 61 32 54 22 53 22 50 17 47 17 54 53 50 47 ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 570. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) Static pressure 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 1000 900 800 700 600 500 400 300 200 100 3.5 PWM duty cycle PWM 100% 0% 5 10 15 20 25 30 Airflow 3.0 2.5 2.0 1.5 1.0 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 38 4.0 Static pressure 4.0 (inch H2O) (Pa) 12 VDC DC12 V (CFM) 0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1000 900 800 700 600 500 400 300 200 100 (min-1) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 22000 min-1 20000 13.2 V Fan speed 9GA0412P3K01 12 V 10.8 V 15000 10000 5000 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 5 10 15 20 25 30 Airflow (CFM) 0 6500 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 12 VDC DC12 V 700 300 200 0 50% 0% 5 9GA0412P3G01 10 15 20 25 Airflow 10 15 20 25 0 PWM duty - Speed characteristics example (min-1) 20000 300 200 50% 100 0% 0 1.5 1.0 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 20 Airflow 25 200 10000 5000 4500 min-1 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 20 Airflow 25 (inch H2O) (Pa) 2.0 500 Static pressure 50% 1.5 (min-1) PWM duty cycle 100% PWM100% 20000 400 300 200 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 9GA0412P3M01 10 15 Airflow 20 (CFM) 12 VDC DC12 V 350 (inch H2O) (Pa) 350 0.25 0 50 0% 0 PWM PWM duty cycle 100% 50% 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 5 10 15 20 (CFM) Airflow Static pressure Static pressure 1.0 250 100 100 (%) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 20000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 1.25 300 1.25 300 0.5 0 PWM duty cycle PWM Airflow Operating voltage range (inch H2O) (Pa) 150 3500 min-1 With pulse sensor with PWM control function PWM duty cycle 200 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) (CFM) 0 5 10 15 20 14500 min-1 10000 5000 100 1.0 250 0.75 0.5 0.25 0 200 150 13.2 V 12 V 10.8 V 100 15000 Fan speed 5 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15000 13.2 V 12 V 10.8 V 1.0 0.5 PWM duty - Speed characteristics example 0% 0 100 (%) 0 duty cycle PWMPWM (CFM) Operating voltage range 200 0 16500 min-1 With pulse sensor with PWM control function PWM duty cycle PWM 100% 100 300 0 400 300 13.2 V 12 V 10.8 V 400 (CFM) 12 VDC DC12 V 1.0 Fan speed PWM PWM duty cycle 100% 2.0 500 0.75 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15000 2.0 500 Fan speed 400 (inch H2O) (Pa) 0 100 (%) PWM duty cycle PWM (CFM) PWM duty cycle 100% PWM100% 700 PWM duty cycle Static pressure 5 5000 4500 min-1 2.5 600 600 9GA0412P3H01 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) (inch H2O) (Pa) 12 VDC DC12 V 0 1.5 200 0.5 100 10000 Airflow Static pressure Static pressure 0 300 0 2.0 500 0.5 12 V 10.8 V 400 Operating voltage range 700 1.0 1.0 15000 With pulse sensor with PWM control function (inch H2O) (Pa) 1.5 1.5 (CFM) PWM duty cycle 2.5 13.2 V 2.0 500 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 18000 min-1 Fan speed Static pressure Static pressure 0 PWM PWM duty cycle 100% 400 0.5 100 20000 2.5 600 2.0 500 1.0 (min-1) PWM duty cycle 100% PWM100% 700 2.5 600 1.5 PWM duty - Speed characteristics example 12500 min-1 10000 5000 3500 min-1 50 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 20 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 39 DC Fan 40 mm sq. 9GA0412P3J01 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0424P3J001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 24 VDC DC24 V 700 300 200 50% 100 10 15 20 Airflow 9GA0424P3G001 25 0 300 200 50% 100 5 10 15 20 25 Airflow Static pressure Static pressure 50% 10 15 Airflow 9GA0424P3M001 20 16500 min-1 10000 5000 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 Airflow 20 25 100 (%) 0 PWM duty cycle PWM (CFM) (min-1) PWM duty cycle 100% 100% 20000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 15000 26.4 V 300 24 V 200 0.5 PWM duty - Speed characteristics example 400 21.6 V 14500 min-1 10000 5000 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 24 VDC DC24 V 5 (inch H2O) (Pa) 10 15 Airflow 20 100 (%) 0 PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% 100% 350 20000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 1.25 300 PWM PWM duty cycle 100% 150 50% 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 20 (CFM) Airflow Static pressure Static pressure 40 21.6 V 200 1.0 (CFM) 1.25 300 0 0 24 V Operating voltage range 350 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 50 1.5 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 300 2.0 500 PWM duty cycle 0.25 20000 26.4 V 400 (inch H2O) (Pa) 200 100 (min-1) PWM duty cycle 100% 100% Operating voltage range 1.0 0.5 PWM duty - Speed characteristics example 15000 0 PWM PWM duty cycle 100% 100 1.0 (CFM) 24 VDC DC24 V 300 1.5 0 400 200 100 (%) 0 PWM duty cycle PWM (CFM) With pulse sensor with PWM control function 2.0 500 0.75 25 Airflow 2.0 500 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 1.0 250 20 15 Fan speed 400 0 10 Fan speed Static pressure Static pressure PWM PWM duty cycle 100% (inch H2O) (Pa) 0 5 700 PWM duty cycle 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 2.5 600 9GA0424P3H001 1.5 5000 (inch H2O) (Pa) 24 VDC DC24 V 2.0 500 0 10000 100 Operating voltage range 700 0 200 0 2.5 600 0.5 24 V 21.6 V 300 With pulse sensor with PWM control function (inch H2O) (Pa) 1.0 400 (CFM) PWM duty cycle 1.5 1.0 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 1.5 15000 26.4 V 2.0 500 Fan speed PWM duty cycle PWM 100% 400 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 18000 min-1 15000 1.0 250 0.75 0.5 0.25 0 26.4 V 200 Fan speed 0 Static pressure Static pressure 0.5 20000 2.5 600 2.0 500 1.0 (min-1) PWM duty cycle 100% PWM100% 700 2.5 600 1.5 PWM duty - Speed characteristics example 24 V 21.6 V 150 100 12500 min-1 10000 5000 50 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) DC (With ribs) DC Fan 40 mm sq. 4-o3.50.3 Mounting hole (10) 320.3 400.3 +30 320 0 Lead wire AWG26 UL 1007 320.3 (4) (4) 280.5 400.3 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 41 DC Fan 40x40x28 mm San Ace 40 9GE type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 55 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GE0412P3K03 12 9GE0412P3J03 10.8 to 13.2 9GE0412P3G03 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.84 0.07 0.65 0.05 0.47 0.05 10.08 0.84 7.8 0.6 5.64 0.6 16500 3000 15000 2650 13000 2400 0.76 0.13 0.69 0.12 0.6 0.11 26.8 4.6 24.4 4.2 21.2 3.9 415 13 343.0 10.7 260 8.2 [inchHO] 1.666 0.052 1.378 0.042 1.044 0.033 SPL Operating temperature Expected life [dB (A)] [C] [h] 58 17 56 14 52 13 -20 to +60 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 573. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GE0412P3K03 With pulse sensor with PWM control function PWM duty cycle Operating voltage range PWM duty - Speed characteristics example (inch H2O) (Pa) Static pressure 1.50 400 1.25 300 1.00 250 0.75 200 0.50 0.25 0 50% 150 100 0% 50 0 0 42 0.2 5 0.4 10 15 0.6 20 Airflow 0.8 0.25 0 0 2.00 PWM duty cycle PWM 100% 350 500 450 400 350 300 250 200 150 100 50 (m3/min) 25 30 (CFM) 1.75 1.50 1.25 1.00 0.75 0.50 (min-1) PWM duty cycle 100% PWM100% 20000 13.8 V 12 V 10.8 V Fan speed 1.75 (inch H2O) (Pa) 12 VDC DC12 V 450 Static pressure 2.00 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16500 min-1 15000 10000 5000 3000 min-1 0.3 0 0.6 0.9 (m3/min) 5 10 15 20 25 30 Airflow (CFM) 0 100 (%) PWM duty cycle PWM PWM duty cycle Operating voltage range (inch H2O) (inch H2O)(Pa) (Pa) (inch H2O) (inch H2O)(Pa) (Pa) 12 VDC DC12 VV DC12 1.61.6 400 400 1.01.0 250 250 0.80.8 200 200 50% 50% 0.60.6 150 150 0.20.2 5050 00 0.60.6 150 150 0.40.4 100 100 0% 0% 3 3 /min) (m(m /min) 0.20.2 0.40.4 0.60.6 0.80.8 9GE0412P3G03 Operating voltage range 0.75 0.50 0.25 0 PWM duty - Speed characteristics example (inch H2O) (Pa) 1.75 12 VDC DC12 V 350 1.50 300 PWM duty cycle PWM 250 Static pressure Static pressure 1.00 100% 200 50% 150 100 50 0% 0 5 10 15 Airflow 20 350 300 1.00 250 0.75 0.50 20000 13.2 V 12 V 200 10.8 V 150 100 0.25 50 0 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15000 13000 min-1 10000 5000 2400 min-1 0.2 0 25 (CFM) (min-1) PWM duty cycle 100% PWM100% 400 1.25 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 100 (%) 0 PWM duty cycle PWM With pulse sensor with PWM control function (inch H2O) (Pa) 1.25 3 3 (m(m /min) /min) 0.20.2 0.40.4 0.60.6 0.80.8 Airflow PWM duty cycle 1.50 10000 2650 min-1 (CFM) 0 0 5 5 1010 1515 2020 2525 3030(CFM) Airflow 15000 min-1 5000 00 00 (CFM) 0 0 5 5 1010 1515 2020 2525 3030(CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15000 0.20.2 5050 Fan speed 00 10.8 10.8V V 1.01.0 250 250 0.80.8 200 200 0.40.4 100 100 1212V V 1.21.2 300 300 Static pressure Static pressure PWM duty cycle PWM PWM 100% 100% 20000 13.2 13.2V V 1.41.4 350 350 1.21.2 300 300 (min-1) PWM duty cycle 100% PWM100% PWM100% 1.61.6 400 400 1.41.4 350 350 PWM duty - Speed characteristics example 5 0.4 10 15 Airflow 0.6 20 0.8 (m3/min) 25 30 (CFM) 0 100 (%) duty cycle PWMPWM Dimensions (unit: mm) 8-o3.50.3 Mounting hole 40.3 280.5 40.3 40 0.3 32 0.3 +30 320 0 (10) 32 0.3 Lead wire AWG28 UL 1061 40 0.3 Rotating direction Airflow direction 43 DC Fan 40 mm sq. With pulse sensor with PWM control function Fan speed 9GE0412P3J03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards Model no.: 109-059, 109-059H 44 page: p. 532 DC DC Fan DC Fan 40 mm sq. 40x40x28 mm San Ace 40 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -20 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 50 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. 9GV0412K301 9GV0412J301 9GV0412G301 9GV0412H301 9GV0412C301 12 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 10.8 to 12.6 0.84 0.6 0.47 0.31 0.15 10.08 7.2 5.64 3.72 1.8 16500 14700 13000 11600 8300 0.76 0.68 0.6 0.53 0.37 26.8 24.0 21.1 18.7 13.1 415 330 260 207 100 [V] 7 to 13.2 SPL [inchHO] Operating temperature Expected life [dB (A)] 1.668 1.325 1.044 0.831 0.402 [C] 58 55 52 49 41 [h] -20 to +60 40000/60C -20 to +70 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 574. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9GV0412J301 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 1.8 450 450 1.6 400 1.4 350 1.2 300 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 1.75 12.6 V 1.50 Static pressure Static pressure (inch H2O) (Pa) 1.0 12 V 10.8 V 1.25 200 5 10 15 20 Airflow 25 30 (CFM) 0 1.50 13.2 V 300 0.75 0.50 (inch H2O) (Pa) 350 250 With pulse sensor Operating voltage range 400 1.00 0.25 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 9GV0412G301 With pulse sensor Static pressure 9GV0412K301 12 V 150 7V 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 30 (CFM) 350 1.25 300 1.00 250 0.75 200 0.50 0.25 50 400 0 13.2 V 12 V 7V 150 100 50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 30 (CFM) 45 Airflow - Static Pressure Characteristics 9GV0412H301 9GV0412C301 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 1.2 300 0.6 0.8 200 Static pressure Static pressure 1.0 250 13.2 V 0.6 150 12 V 0.4 100 0.2 50 0 0 7V Airflow 140 120 0.4 100 0.3 0.2 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 160 0.5 0.1 0 2 4 6 8 10 12 14 16 18 20 (CFM) 13.2 V 80 12 V 60 40 7V 20 0 0.1 0.2 0.3 0.4 0.5 (m3/min) 0 2 4 6 8 10 12 14 16 (CFM) Airflow Dimensions (unit: mm) (With ribs) 400.3 4-o3.50.3 Mounting hole Lead wire AWG26 UL 1007 +30 320 0 320.3 320.3 400.3 With pulse sensor 280.5 (4) (4) (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards Model no.: 109-059, 109-059H 46 page: p. 532 DC DC Fan San Ace 40 9P type DC Fan 40 mm sq. 40x40x28 mm Model 109P0424R3013 is not certified. General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 52 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0405H3013 109P0405F3013 109P0412K3013 109P0412J3013 109P0412G3013 109P0412B3013 109P0412H3013 109P0412F3013 109P0412M3013 109P0424R3013 109P0424J3013 109P0424G3013 109P0424B3013 109P0424H3013 109P0424F3013 5 [V] 4.5 to 5.5 8 to 13.2 7 to 13.2 12 7 to 13.8 10.2 to 13.8 12 to 26.4 24 12 to 27.6 14 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.68 0.28 0.55 0.35 0.31 0.28 0.195 0.105 0.045 0.25 0.18 0.19 0.13 0.095 0.055 3.4 1.4 6.6 4.2 3.72 3.36 2.34 1.26 0.54 6 4.32 4.56 3.12 2.28 1.32 8700 6700 15500 12500 11500 10300 8700 6700 4100 14000 12500 11500 10300 8700 6700 0.32 0.244 0.59 0.46 0.42 0.38 0.32 0.244 0.15 0.51 0.46 0.42 0.38 0.32 0.244 11.3 8.6 20.8 16.2 14.8 13.4 11.3 8.6 5.3 18.0 16.2 14.8 13.4 11.3 8.6 102.9 58.8 340 210 179 143 102.9 58.8 21.6 263.4 210 179 143 102.9 58.8 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.414 0.236 1.365 0.843 0.719 0.574 0.414 0.236 0.087 1.057 0.843 0.719 0.574 0.414 0.236 37 30 50 44 42 40 37 30 20 47 44 42 40 37 30 [C] [h] -20 to +70 40000/60C 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 562 to 563. Lock sensor PWM control Airflow - Static Pressure Characteristics 109P0405H3013 109P0405F3013 With pulse sensor Operating voltage range Operating voltage range 0.35 0.4 0.2 0.30 Static pressure Static pressure 5.5 V 5V 100 4.5 V 50 0.25 0 0.1 0 0.2 5 0.3 10 Airflow 0.4 (m3/min) 15 (CFM) 400 1.4 350 70 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 10 0.2 50 0 0 0 0.15 40 0 5.5 V 60 50 0.05 0 1.6 80 0.20 0.10 (inch H2O) (Pa) 90 Static pressure 150 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.6 109P0412K3013 With pulse sensor 5V 4.5 V 30 20 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 13.2 V 12 V 8V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 47 Airflow - Static Pressure Characteristics 109P0412J3013 109P0412G3013 With pulse sensor Operating voltage range Operating voltage range 12 V 0.06 150 0.04 100 0.02 50 0 0 7V 0.1 0 0.2 5 109P0412H3013 0.3 0.4 10 15 Airflow 0.5 (m3/min) 0.4 100 0.2 50 0 0 0.35 100 7V 50 0.30 0.25 0 0.1 0 0.2 0.3 5 10 15 200 0.6 150 0.4 100 0.2 50 0 0 10 0.5 15 Airflow (m3/min) 40 0.10 7V 10 0 0.1 2 0.2 4 6 8 Airflow 10 24 V 12 V 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 5 10 15 20 (CFM) 200 150 0.04 100 0.02 50 0 0 109P0424B3013 0.6 12 V 0.1 0.2 5 0.3 0.4 10 15 Airflow 0.5 (m3/min) 12 V 50 0 0.1 0 48 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) (CFM) 0 With pulse sensor 12 V 10.2 V 20 0.05 10 0 0.05 1 2 0.10 0.15 3 5 4 Airflow 0.20 (m3/min) 6 7 (CFM) With pulse sensor 0.8 200 26.4 V 24 V 12 V 0.6 150 0.4 100 0.2 50 0 0 0.1 0 0.2 5 0.3 0.4 10 0.5 15 Airflow (m3/min) 20 (CFM) With pulse sensor (inch H2O) (Pa) 150 0.35 100 50 0.30 0.25 0 0.1 0 0.2 5 0.3 10 Airflow 0.4 (m3/min) 15 (CFM) 90 60 0.15 40 0 24 V 70 50 0.10 27.6 V 80 0.20 0.05 0 (CFM) Operating voltage range 12 V 0.2 0.5 (m3/min) 15 13.8 V 109P0424F3013 With pulse sensor 24 V 0.4 0.4 Airflow 0.10 20 (CFM) Static pressure 0.4 100 0.2 Static pressure Static pressure 26.4 V 24 V 0.3 10 40 0 27.6 V 0.6 150 0.2 5 30 0 26.4 V (inch H2O) (Pa) 0.8 200 0.1 Operating voltage range Operating voltage range (inch H2O) (Pa) 0 1.0 250 109P0424H3013 With pulse sensor Operating voltage range 0 7V (inch H2O) (Pa) 0 Airflow 50 12 V 109P0424G3013 With pulse sensor 24 V 0.06 0.2 (CFM) (inch H2O) (Pa) 0.08 100 13.8 V 0 0.3 (m3/min) Operating voltage range 26.4 V 0.4 0.15 20 250 150 Operating voltage range 30 0.10 0.6 109P0412M3013 12 V 60 0.15 200 20 (CFM) 13.8 V 0 Static pressure Static pressure 0.8 0.4 0.8 (inch H2O) (Pa) 109P0424J3013 With pulse sensor (inch H2O) (Pa) 250 0.3 With pulse sensor 70 (CFM) Operating voltage range 1.0 5 80 50 0 0.4 (m3/min) Airflow 109P0424R3013 300 0.2 90 0.20 0.05 1.2 0.1 (inch H2O) (Pa) 150 12 V 0 7V Operating voltage range Static pressure Static pressure 150 0 13.8 V 0.2 0.6 13.2 V 12 V 109P0412F3013 With pulse sensor (inch H2O) (Pa) 0.4 200 20 (CFM) Operating voltage range 0.6 0.8 (inch H2O) (Pa) Static pressure 13.2 V 250 Static pressure 200 1.0 Static pressure 0.08 Static pressure Static pressure 250 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.10 109P0412B3013 With pulse sensor 14 V 30 20 10 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 4-o3.50.3 Mounting hole 280.5 (4) (4) DC Fan 40 mm sq. 400.5 320.3 DC Dimensions (unit: mm) 320.3 400.5 +30 320 0 (10) Lead wire AWG24 UL 1007 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (15) .5 38 320.3 4-o3.7 (15) Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 49 DC Fan 52x52x15 mm San Ace 52 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 40 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9GA0512P7G001 9GA0512P7A001 9GA0512P7H001 9GA0512P7M001 9GA0524P7G001 9GA0524P7A001 9GA0524P7H001 9GA0524P7M001 12 24 [V] 10.2 to 13.8 20.4 to 27.6 PWM duty cycle* [%] 100 100 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.13 0.08 0.05 0.04 0.07 0.05 0.03 0.02 1.56 0.96 0.6 0.48 1.68 1.2 0.72 0.48 7800 6300 4300 3400 7800 6300 4300 3400 0.5 0.4 0.275 0.215 0.5 0.4 0.275 0.215 17.7 14.1 9.7 7.6 17.7 14.1 9.7 7.6 91.5 59 27.5 17 91.5 59.0 27.5 17.0 [inchHO] 0.367 0.237 0.11 0.068 0.367 0.237 0.11 0.068 SPL Operating temperature Expected life [dB (A)] [C] [h] 38 32 22 16 38 32 22 16 -20 to +70 40000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 570. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0512P7G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.4 0.3 0.2 0.1 0 100 0.4 80 PWM duty cycle PWM 100% 60 40 50% 20 0 0 50 0.5 12 VDC DC12 V 120 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) Static pressure Static pressure 0.5 0.3 0.2 0.1 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 120 8000 13.8 V 100 10.2 V 60 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7800 min-1 6000 12 V 80 Fan speed PWM duty cycle 40 4000 2000 20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 80 60 0.2 PWM PWM duty cycle 100% 40 0.1 0 0.2 5 0.3 0.4 10 15 Airflow 9GA0512P7H001 Static pressure 40 0.10 20 PWM duty cycle PWM 100% 50% 0.1 0 0.2 5 0.3 10 15 Static pressure 1.0 25 0.8 20 0.6 15 0.4 10 0.2 5 50% 0 0.1 PWM duty cycle PWM 100% 0.2 4 6 Airflow 9GA0524P7G001 8 10 Static pressure 0.1 0 20 0.05 0 1.2 30 1.0 25 0.8 20 0.6 15 0.4 10 0.2 5 0.5 PWM duty cycle PWM 100% 40 50% 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 5000 0.1 0.2 0.3 5 0.4 (m3/min) 10 15 4300 min-1 4000 3000 2000 Airflow 0 100 (%) PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 6000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 13.8 V 12 V 10.2 V 4000 3400 min-1 3000 2000 1000 0 0.1 2 0.2 4 6 Airflow 0.3 (m3/min) 8 10 0 100 (%) PWM duty cycle PWM (CFM) Operating voltage range 0.4 0 6000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 1000 0 100 0 (min-1) 10 (inch H2O) (Pa) 20 PWM duty - Speed characteristics example 10.2 V (CFM) 24 VDC DC24 V 60 100 (%) With pulse sensor with PWM control function 120 80 Airflow 0 PWM duty cycle PWM (CFM) 12 V 0.10 0 0.3 (m3/min) (inch H2O) (Pa) 0.2 30 (inch H2O) (Pa) PWM duty cycle 0.3 15 PWM duty cycle 100% PWM100% 0 12 VDC DC12 V 30 0.4 10 0.5 (m3/min) Operating voltage range 1.2 0.5 0.4 With pulse sensor with PWM control function (inch H2O) (Pa) 2 0.3 13.8 V (CFM) PWM duty cycle 0 0.2 5 40 0 0.4 (m3/min) Airflow 9GA0512P7M001 0 0.1 0 0.15 0 0 (inch H2O) (Pa) 30 0 4000 2000 20 Operating voltage range 12 VDC DC12 V 10 10.2 V 40 With pulse sensor with PWM control function (inch H2O) (Pa) 0.05 0.2 (CFM) PWM duty cycle 0.15 12 V 0 0.5 (m3/min) 6300 min-1 6000 Fan speed 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 13.8 V 80 60 0.1 8000 Fan speed 0 50% 0.3 (min-1) PWM duty cycle 100% PWM100% 100 10 15 Airflow 20 (CFM) 0.3 0.2 0.1 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 120 8000 27.6 V 100 20.4 V 60 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7800 min-1 6000 24 V 80 Fan speed 20 Static pressure 0.1 Static pressure 0.4 Static pressure 0.3 (inch H2O) (Pa) 12 VDC DC12 V 100 Static pressure Static pressure 0.4 PWM duty - Speed characteristics example Fan speed PWM duty cycle 40 4000 2000 20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) 0 100 (%) PWM duty cycle PWM 51 DC Fan 52 mm sq. 9GA0512P7A001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0524P7A001 With pulse sensor with PWM control function Operating voltage range 0.4 80 60 0.2 PWM PWM duty cycle 100% 40 50% 0 0 0.1 0 0.2 5 0.3 0.4 10 15 Airflow 9GA0524P7H001 Static pressure 30 0.10 20 PWM duty cycle PWM 100% 50% 0.1 0 0.2 5 0.3 10 Static pressure 52 5 0.3 0.4 10 0.5 (m3/min) 15 Airflow 0 100 (%) PWM duty cycle PWM (CFM) 15 (min-1) PWM duty cycle 100% PWM100% 30 6000 20 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 24 V 0.10 0.05 PWM duty - Speed characteristics example 20.4 V 10 4300 min-1 4000 3000 2000 1000 0 0.1 0 0.2 0.3 5 0.4 (m3/min) 10 15 Airflow 0 100 (%) PWM duty cycle PWM (CFM) With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 24 VDC DC24 V 1.2 30 1.0 25 0.8 20 0.6 15 0.4 10 0.2 5 50% 0 0.1 PWM duty cycle PWM 100% 2 0.2 27.6 V (CFM) PWM duty cycle 0 0.1 40 0 0.4 (m3/min) Airflow 9GA0524P7M001 0 0 0 0.15 0 4000 2000 20 (inch H2O) (Pa) 24 VDC DC24 V 10 20.4 V 40 Operating voltage range 40 0 0.2 With pulse sensor with PWM control function (inch H2O) (Pa) 0.05 24 V (CFM) PWM duty cycle 0.15 6300 min-1 6000 0 0.5 (m3/min) Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 27.6 V 80 60 0.1 8000 Fan speed 20 0.3 (min-1) PWM duty cycle 100% PWM100% 100 4 0.3 (m3/min) 0.2 6 Airflow 8 10 (CFM) 1.2 30 1.0 25 0.8 20 0.6 15 0.4 10 0.2 5 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 6000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 27.6 V Fan speed 0.1 Static pressure 0.3 (inch H2O) (Pa) 24 VDC DC24 V 100 Static pressure Static pressure 0.4 Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 24 V 20.4 V 4000 3000 3400 min-1 2000 1000 0 0 0.1 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0 100 (%) PWM duty cycle PWM DC Dimensions (unit: mm) DC Fan 52 mm sq. 4-o4.50.3 Mounting hole 420.3 520.5 +50 300 0 (10) Lead wire 420.3 520.5 AWG26 UL 1007 (3) (3) 150.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 50.4 420.3 50.4 o5 3 420.3 4-o 4.5 Options Finger guards page: p. 532 Model no.: 109-149E, 109-149 53 DC Fan 52x52x15 mm San Ace 52 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 55 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 109P0505M701 109P0512A701 109P0512H701 109P0512M701 109P0524A701 109P0524H701 109P0524M701 Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 5 4.5 to 5.5 10.2 to 13.8 0.15 0.21 0.1 0.07 0.11 0.05 0.04 0.75 2.52 1.2 0.84 2.64 1.2 0.96 3700 6800 4600 3700 6800 4600 3700 0.205 0.375 0.255 0.205 0.375 0.255 0.205 7.24 13.25 9.0 7.24 13.24 9.0 7.24 21.4 69.7 31.9 21.4 69.7 31.9 21.4 12 7 to 13.8 24 14 to 27.6 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.086 0.28 0.128 0.086 0.28 0.128 0.086 [C] 22 36 27 22 36 27 22 [h] 60000/60C 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P0505M701 109P0512A701 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 5.5 V 20 5V 0.06 0.04 4.5 V 10 0.02 0 0 0.1 0 54 0.05 0 0 0.35 0.10 0.08 100 90 80 70 60 50 40 30 20 10 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 0.30 0.25 0.20 0.15 0.10 (inch H2O) (Pa) 0.20 Static pressure 0.40 With pulse sensor Operating voltage range (inch H2O) (Pa) 30 Static pressure Static pressure 0.12 109P0512H701 With pulse sensor 13.8 V 12 V 10.2 V 0.1 0.2 0.3 0.4 0.5 (m3/min) 0 2 4 6 8 10 12 14 16 18 (CFM) Airflow 0.15 50 40 13.8 V 30 12 V 0.10 20 0.05 0 7V 10 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) 109P0524A701 With pulse sensor Operating voltage range Operating voltage range 13.8 V 20 12 V 0.06 0.04 7V 10 0.02 0 0.05 0 0.1 0 109P0524M701 2 0.2 4 6 (m3/min) 0 0 8 Airflow (CFM) 0.30 0.25 0.20 0.15 0.10 (inch H2O) (Pa) 0.20 Static pressure 0.10 0.08 100 90 80 70 60 50 40 30 20 10 0.35 Static pressure Static pressure 0.40 30 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.12 109P0524H701 With pulse sensor DC Fan 52 mm sq. 109P0512M701 DC Airflow - Static Pressure Characteristics 27.6 V 24 V 14 V 0.1 0.2 0.3 0.4 0.15 0 2 4 6 8 10 12 14 16 18 (CFM) 40 27.6 V 30 24 V 0.10 20 0.05 0 0.5 (m3/min) 50 14 V 10 0 0.1 0 Airflow 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.12 30 0.10 0.08 27.6 V 20 24 V 0.06 0.04 14 V 10 0.02 0 0 0.1 0 2 4 0.2 6 Airflow (m3/min) 8 (CFM) Dimensions (unit: mm) 520.5 4-o3.70.3 Mounting hole +1 15 0 420.3 (3) Lead wire AWG24 UL 1007 (3) 420.3 520.5 +50 300 0 (10) Rotating direction Airflow direction 55 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 51 51 4-o3.7 420.3 53 (24) (24) 420.3 Options Finger guards Model no.: 109-149E, 109-149 56 page: p. 532 DC DC Fan DC Fan 60 mm sq. 60x60x10 mm San Ace 60 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 35 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9GA0612G9001 9GA0612H9001 9GA0612L9001 12 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 7.0 to 13.2 0.27 0.14 0.03 3.24 1.68 0.36 6200 5000 2300 0.62 0.5 0.23 21.9 17.6 8.1 66 42.9 9.1 [V] 7.0 to 13.8 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] 43 37 17 -20 to +60 -20 to +70 -10 to +70 0.26 0.17 0.037 [h] 40000/60C 70000/40C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 570. PWM control Airflow - Static Pressure Characteristics 9GA0612H9001 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 80 80 0.25 60 0.20 50 0.15 40 0.10 0.05 0 0.30 70 13.2 V Static pressure Static pressure 0.30 12 V 30 7V 20 60 0.20 50 0.15 40 0.10 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 (CFM) 0 (inch H2O) (Pa) 0.06 13.8 V 12 V 30 7V 20 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 20 Airflow 25 (CFM) 16 14 0.05 12 0.04 10 0.03 8 0.02 0.01 10 0 With pulse sensor Operating voltage range 70 0.25 0.05 10 0 9GA0612L9001 With pulse sensor Static pressure 9GA0612G9001 0 13.8 V 12 V 6 4 7V 2 0 0 0.05 0.10 0.15 0.20 0.25 0.30 (m3/min) 2 4 6 Airflow 8 10 (CFM) 57 Dimensions (unit: mm) 500.3 600.5 4-o4.30.3 Mounting hole 300 +50 0 (10) 500.3 600.5 Lead wire (3) (3) 100.5 AWG28 UL 1007 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 58 4-o4.5 500.3 3 58 500.3 o6 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 58 Resin finger guards page: p. 539 DC DC Fan DC Fan 60 mm sq. 60x60x15 mm San Ace 60 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 50 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GA0612P7G01 12 10.2 to 13.8 24 20.4 to 27.6 9GA0612P7H01 9GA0624P7G01** * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 [min-1] [A] [W] 0.16 0.05 0.1 0.03 0.08 1.92 0.6 1.2 0.36 1.92 5900 1500 4900 1300 5900 Max. airflow Max. static pressure [m/min] [CFM] [Pa] 0.68 0.17 0.56 0.15 0.68 24 6.0 19.7 5.3 24.0 80 5.2 55.6 3.9 80 [inchHO] 0.32 0.02 0.223 0.015 0.32 SPL Operating temperature Expected life [dB (A)] [C] [h] 38 10 34 8 38 -20 to +70 40000/60C (70000/40C) SPL Operating temperature Expected life [dB (A)] [C] ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 571. Pulse sensor Lock sensor The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Model no. [V] 9GA0612G701 9GA0612H701 9GA0612M701 9GA0612L701 12 9GA0624M701 24 [V] 6 to 13.8 12 to 27.6 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.16 0.1 0.08 0.03 1.92 1.2 0.96 0.36 5900 4900 3900 2800 0.68 0.56 0.45 0.31 24 19.7 15.9 10.9 80 55.6 35.3 18 0.05 1.2 3900 0.45 15.9 35.3 [inchHO] 0.32 0.223 0.142 0.072 38 34 28 17 0.142 28 [h] 40000/60C (70000/40C) -20 to +70 60000/60C 40000/60C (70000/40C) The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 570 to 571. Lock sensor PWM control Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Static pressure (inch H2O) (Pa) 12 VDC DC12 V 0.45 110 0.40 100 0.35 90 80 0.30 70 PWM duty cycle PWM 0.25 60 100% 0.20 50 0.15 40 30 50% 0.10 20 0% 0.05 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 30 (CFM) (inch H2O) (Pa) PWM duty - Speed characteristics example 0 (min-1) PWM duty cycle 100% PWM100% 0.45 110 0.40 100 13.8 V 0.35 90 80 0.30 70 0.25 60 12 V 0.20 50 10.2 V 0.15 40 30 0.10 20 0.05 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 5 10 15 20 Airflow 25 6000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5900 min-1 5000 Fan speed PWM duty cycle Static pressure 9GA0612P7G01 4000 3000 2000 1500 min-1 1000 (m3/min) 30 (CFM) 0 100 (%) PWM duty cycle PWM 59 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0612P7H01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 80 0.20 50 0.15 40 0.05 0 PWM duty cycle PWM 100% 30 20 50% 0% 10 0 5 15 Airflow 20 0.20 0.15 0.10 0.05 0 50% 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 5 9GA0612G701 10 15 20 Airflow (m3/min) 0.10 0 13.8 V 12 V 6V 5 10 15 20 Airflow 25 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 (min-1) 20.4 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 5 15 10 20 25 With pulse sensor 40 Airflow 12 V 0.20 13.8 V 12 V 20 6V 0.05 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 (m3/min) 0 2 4 6 8 10 12 14 (CFM) Airflow 0 0.15 50 40 13.8 V 30 0.10 0.05 12 V 20 10 6V 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 10 15 Airflow 20 (CFM) With pulse sensor 50 40 27.6 V 30 6V With pulse sensor (inch H2O) (Pa) 9GA0624M701 0.10 100 (%) 0 PWM duty cycle PWM Operating voltage range Operating voltage range 0.15 2000 9GA0612M701 (inch H2O) (Pa) 13.8 V 3000 (m3/min) With pulse sensor 30 0 0.20 4000 30 (CFM) 60 0.15 0 5900 min-1 1000 50 0.10 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 70 (CFM) (inch H2O) (Pa) 0.12 100 (%) PWM duty cycle PWM PWM duty - Speed characteristics example 24 V 0.20 0.05 Operating voltage range Static pressure 0.25 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 9GA0612L701 Airflow 0 (m3/min) 25 (CFM) Operating voltage range 0.30 0 20 15 27.6 V 9GA0612H701 With pulse sensor Static pressure 0.15 10 1300 min-1 6000 0 Static pressure Static pressure 0.20 5 PWM duty cycle 100% PWM100% 0.45 110 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0 0 80 0.05 60 0 (inch H2O) (Pa) 0.25 1000 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 110 100 90 80 70 60 50 40 30 20 10 0.30 2000 10 (inch H2O) (Pa) 0.35 3000 20 25 30 (CFM) Operating voltage range 0.40 10.2 V (inch H2O) (Pa) PWM duty cycle PWM 100% 0 12 V 30 0 Static pressure Static pressure 0.25 40 4900 min-1 4000 13.8 V Operating voltage range 24 VDC DC24 V 110 100 90 80 70 60 50 40 30 20 10 0.30 0.15 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.35 50 25 (CFM) PWM duty cycle 0.40 0.20 0.05 10 9GA0624P7G01 0.45 60 0.10 5000 70 0.25 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 80 Fan speed 60 (min-1) PWM duty cycle 100% PWM100% Static pressure 0.25 0.10 0.30 70 Static pressure Static pressure 0.30 (inch H2O) (Pa) 12 VDC DC12 V PWM duty - Speed characteristics example Fan speed PWM duty cycle 24 V 20 10 0 12 V 0.1 0.2 0.3 0.4 0.5 (m3/min) 0 2 4 6 8 10 12 14 16 18 (CFM) Airflow 0 0 0.1 0.2 0.3 0.4 0.5 (m3/min) 0 2 4 6 8 10 12 14 16 18 (CFM) Airflow (With pulse sensor with PWM control function) DC Dimensions (unit: mm) 150.5 (3) (3) DC Fan 60 mm sq. 4-o4.50.3 Mounting hole 300 500.3 600.5 Lead wire AWG28 UL 1007 +50 0 (10) 500.3 Airflow direction 600.5 Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 58 4-o4.7 500.3 3 58 500.3 o6 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 61 DC Fan 60x60x15 mm San Ace 60 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 60 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0605H701 109P0605M701 109P0612K701 109P0612S701 109P0612H701 109P0612M701 109P0612B701 109P0624J701 109P0624S701 109P0624H701 109P0624M701 [V] 5 4.5 to 5.5 10.2 to 13.8 12 7 to 13.8 10.2 to 13.8 24 14 to 27.6 20.4 to 27.6 0.26 0.15 0.26 0.15 0.09 0.07 0.05 0.14 0.08 0.06 0.04 Rated speed Max. airflow [W] [min-1] [m/min] 1.3 0.75 3.12 1.8 1.08 0.84 0.6 3.36 1.92 1.44 0.96 4100 3100 6500 5000 4100 3100 2200 6200 5000 4100 3100 0.4 0.3 0.62 0.48 0.4 0.3 0.21 0.61 0.48 0.4 0.3 [A] [CFM] 14.1 10.6 21.9 17.0 14.1 10.6 7.42 21.5 16.9 14.1 10.6 Max. static pressure [Pa] [inchHO] 38.2 22.6 99.3 58.8 38.2 22.6 11.7 86.5 58.8 38.2 22.6 SPL Operating temperature Expected life [dB (A)] 0.153 0.091 0.399 0.236 0.153 0.091 0.047 0.347 0.236 0.153 0.091 32 25 45 36 32 25 21 44 36 32 25 [C] [h] -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P0605H701 109P0605M701 With pulse sensor Operating voltage range Operating voltage range 0.12 0.10 0.05 0 50 5.5 V 40 5V 30 4.5 V 20 0 30 0.10 0.08 5.5 V 20 5V 0.06 0.04 4.5 V 10 0.02 10 0.1 0.2 0.3 0.4 0 2 4 6 8 10 12 14 16 Airflow 62 Static pressure Static pressure 0.15 (inch H2O) (Pa) (inch H2O) (Pa) 60 0.5 (m3/min) (CFM) 0 With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.20 109P0612K701 With pulse sensor 0 0.1 0 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 130 120 110 100 90 80 70 60 50 40 30 20 10 0 13.8 V 12 V 10.2 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 5 10 15 20 Airflow 25 (m3/min) 30 (CFM) Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 80 60 0.25 70 0.20 50 0.15 40 0.10 13.8 V 60 Static pressure Static pressure 0.30 12 V 10.2 V 30 20 0.05 10 0 0 0 2 4 6 8 10 12 14 16 18 20 Airflow 0.20 0.15 0.10 0.05 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 109P0612B701 109P0612M701 With pulse sensor 0.16 Operating voltage range 13.8 V 40 12 V 30 7V 20 10 0 0.1 0.2 0.3 0.4 15 13.8 V 0.04 10 0.02 5 0 12 V 10.2 V 0 0 109P0624H701 2 4 6 Airflow 8 10 0 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) With pulse sensor 24 V 80 14 V 60 20 0.25 60 0.20 50 0.15 40 0.10 0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 10 15 20 Airflow 25 (CFM) 80 70 0 27.6 V 24 V 14 V 30 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 2 4 6 8 10 12 14 16 18 20 22 (CFM) Airflow With pulse sensor (inch H2O) (Pa) 0.16 40 0.14 50 27.6 V 40 24 V 30 14 V 20 10 0 0.1 2 Operating voltage range Static pressure Static pressure 0.05 100 0 60 0.10 0.30 27.6 V 0 0 0.35 40 0.10 10 (inch H2O) (Pa) 109P0624M701 With pulse sensor (inch H2O) (Pa) 0.15 0.20 0.04 Operating voltage range 120 (CFM) Operating voltage range 0.20 0.30 0 0.3 (m3/min) 0.2 0.1 0.40 10.2 V 0.06 0 Static pressure Static pressure Static pressure 0.06 12 V 20 109P0624S701 With pulse sensor Operating voltage range 0.50 0.08 (CFM) Airflow 20 13.8 V 30 0.10 0 0.5 (m3/min) (inch H2O) (Pa) 0.08 0.12 0.02 0 2 4 6 8 10 12 14 16 (inch H2O) (Pa) 40 0.14 109P0624J701 With pulse sensor Operating voltage range (inch H2O) (Pa) 50 (CFM) With pulse sensor DC Fan 60 mm sq. 109P0612H701 With pulse sensor Static pressure 109P0612S701 DC Airflow - Static Pressure Characteristics 0.12 27.6 V 30 0.10 0.08 24 V 20 20.4 V 0.06 0.04 10 0.02 0.1 0.2 0.3 0.4 0.5 (m3/min) 0 2 4 6 8 10 12 14 16 Airflow (CFM) 0 0 0.1 0 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) 63 Dimensions (unit: mm) +1 60 0 (4) 500.3 (4) Lead wire AWG24 UL 1007 +50 300 0 500.3 +1 60 0 4-o4.30.3 Mounting hole +1 15 0 (10) Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 58 500.3 58 500.3 3 o6 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 64 Resin finger guards page: p. 539 DC DC Fan DC Fan 60 mm sq. 60x60x20 mm San Ace 60 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 70 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9GA0612P6G001 9GA0612P6S001 9GA0624P6G001 9GA0624P6S001 [V] 12 10.8 to 13.2 24 21.6 to 26.4 PWM duty cycle* [%] Rated current Rated input Rated speed 100 100 100 100 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.26 0.15 0.12 0.07 3.12 1.8 2.88 1.68 6850 5500 6850 5500 0.88 0.7 0.88 0.7 31.1 24.7 31.1 24.7 125 81 125 81 [inchHO] 0.5 0.33 0.5 0.33 SPL Operating temperature Expected life [dB (A)] [C] [h] 43 36 43 36 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 571. Pulse sensor The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Model no. [V] 9GA0612H60 01 9GA0612M6001 9GA0624H60 01 9GA0624M6001 [V] 12 10.8 to 13.2 24 21.6 to 26.4 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.09 0.05 0.04 0.03 1.08 0.6 0.96 0.72 4100 2700 4100 2700 0.52 0.34 0.52 0.34 18.4 12.0 18.4 12.0 45 20 45 20 [inchHO] 0.18 0.08 0.18 0.08 SPL Operating temperature Expected life [dB (A)] [C] [h] 29 18 29 18 -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 160 0.6 140 0.5 120 PWM duty cycle PWM 100% 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 0 Static pressure Static pressure 0.6 (inch H2O) (Pa) 12 VDC DC12 V 50% 0.2 5 0.4 0.1 0.6 0.8 1.0 (m3/min) 10 15 20 25 30 35 Airflow (CFM) 0 12 V 10.8 V 80 60 40 7000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6850 min-1 6000 5000 4000 3000 2000 1000 20 0 0 8000 13.2 V 0.4 100 0.2 (min-1) PWM duty cycle 100% PWM100% 160 140 0.5 120 0.3 PWM duty - Speed characteristics example Fan speed 9GA0612P6G001 5 0.2 0.4 0.6 0.8 1.0 (m3/min) 10 15 20 25 30 35 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 65 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0612P6S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.4 100 80 PWM PWM duty cycle 100% 60 0.2 40 10 5 15 20 Airflow 9GA0624P6G001 25 0.6 140 PWM duty cycle PWM 100% 0.3 80 60 0.2 40 0.1 20 0 Static pressure Static pressure 160 0 50% 0.2 5 0.4 0.6 0.8 50% 10 5 15 20 Airflow 25 60 4000 3000 2000 1000 5 0.2 0.4 0.6 0.8 1.0 (m3/min) 10 15 20 25 30 35 (CFM) 0 100 (%) PWM duty cycle PWM 12 V 30 10.8 V PWM duty cycle 100% PWM100% (min-1) 24 V 40 10 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 15 Airflow 20 (CFM) 2000 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 10 15 20 25 Airflow 9GA0624H6001 With pulse sensor Operating voltage range (inch H2O) (Pa) 12 VDC DC12 V 24 VDC DC24 V 60 0.20 50 13.2 V 12 V 0.06 15 10.8 V 0.04 10 5 0.1 0 0 100 (%) 0 PWM duty cycle PWM (CFM) With pulse sensor 0.08 20 0 3000 1000 0.10 25 0.02 4000 20 0 5500 min-1 5000 21.6 V 0.2 0.1 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 26.4 V 80 0.12 30 20 10 PWM duty - Speed characteristics example (inch H2O) (Pa) 13.2 V 5 5000 20 0 0 6850 min-1 6000 40 0 Static pressure Static pressure 66 21.6 V 80 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 24 V 9GA0612M6001 12 VDC DC12 V 40 0 8000 Operating voltage range 60 0 (min-1) 26.4 V 60 (CFM) With pulse sensor (inch H2O) (Pa) 0.20 50 0.3 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 9GA0612H6001 0 0.2 PWM duty - Speed characteristics example Airflow Static pressure Static pressure PWM duty cycle PWM 100% Operating voltage range 0.05 140 0.4 100 40 0.10 160 (inch H2O) (Pa) 24 VDC DC24 V 0.2 0.15 0.3 0 1.0 (m3/min) 60 0 100 (%) 0 PWM duty cycle PWM (CFM) Operating voltage range 80 0 25 With pulse sensor with PWM control function 0.4 100 0 20 PWM duty cycle 100% PWM100% Airflow (inch H2O) (Pa) 20 15 Airflow 0.4 100 0.1 PWM duty cycle 0.1 10 0.5 120 10 15 20 25 30 35 (CFM) 9GA0624P6S001 0.3 5 (inch H2O) (Pa) 24 VDC DC24 V 0.4 100 2000 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) Operating voltage range 0.5 120 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0 0 4000 1000 0 (CFM) PWM duty cycle 0.6 20 Fan speed 0 10.8 V 40 0 5500 min-1 5000 12 V 0.2 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 80 60 0.1 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 13.2 V Fan speed 0 50% 20 0.3 (min-1) Static pressure 0.1 PWM duty cycle 100% PWM100% 0.4 100 Static pressure Static pressure 0.3 (inch H2O) (Pa) 12 VDCV DC12 PWM duty - Speed characteristics example Fan speed PWM duty cycle 2 4 0.2 6 8 0.3 0.4 (m3/min) 10 12 14 Airflow (CFM) 0.15 0.10 0.05 0 26.4 V 40 24 V 30 21.6 V 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) 9GA0624M6001 DC Airflow - Static Pressure Characteristics With pulse sensor (inch H2O) (Pa) 24 VDC DC24 V 0.12 30 Static pressure DC Fan 60 mm sq. Operating voltage range 0.10 25 26.4 V 0.08 20 24 V 0.06 15 21.6 V 0.04 10 0.02 0 5 0.1 0 0 2 4 0.2 6 8 0.3 0.4 (m3/min) 10 12 14 (CFM) Airflow Dimensions (unit: mm) (With pulse sensor with PWM control function) 4-o4.50.3 Mounting hole 500.3 600.5 Lead wire AWG26 UL 1007 +50 300 0 (10) (4) (4) 500.3 200.5 600.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 58 4-o4.5 500.3 58 500.3 3 o6 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 67 DC Fan 60x60x20 mm San Ace 60 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 90 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0612W601 109P0612H601 109P0612M601 109P0624W601 109P0624H601 109P0624M601 109P0648H601 12 Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 6 to 16 0.13 0.13 0.09 0.07 0.07 0.05 0.07 1.56 1.56 1.08 1.68 1.68 1.2 3.36 4200 4200 3200 4200 4200 3200 5600 0.42 0.42 0.3 0.42 0.42 0.3 0.55 14.8 14.8 10.6 14.8 14.8 10.6 19.4 31.8 31.8 18.8 31.8 31.8 18.8 52.9 12 to 30 20.4 to 27.6 48 Max. airflow [A] 10.2 to 13.8 24 Rated speed [V] 43 to 53 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] 31 31 25 31 31 25 41 -20 to +70 0.128 0.128 0.076 0.128 0.128 0.076 0.212 [h] 60000/60C 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P0612W601 109P0612H601 With pulse sensor Operating voltage range 0.10 16 V 40 12 V 30 20 0.05 0 6V 10 0 0.2 0 68 5 0.4 10 15 Airflow 0.6 (m3/min) 20 (CFM) 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 (inch H2O) (Pa) 50 0.12 13.8 V 40 Static pressure 0.15 50 Static pressure Static pressure 60 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.20 109P0612M601 With pulse sensor Operating voltage range 12 V 30 10.2 V 20 10 30 0.10 0.08 13.8 V 20 12 V 0.06 0.04 10.2 V 10 0.02 0 0.2 0 5 0.4 10 15 Airflow 0.6 (m3/min) 20 (CFM) 0 0 0.1 0 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) (CFM) 109P0624H601 With pulse sensor Operating voltage range Operating voltage range 0.10 30 V 40 24 V 30 20 0.05 12 V 10 0 0 0.2 0 109P0648H601 5 0.4 10 0.6 (m3/min) 15 Airflow 20 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 (inch H2O) (Pa) 50 0.12 27.6 V 40 Static pressure 0.15 50 Static pressure Static pressure 60 24 V 30 20.4 V 20 10 30 0.10 0.08 27.6 V 20 24 V 0.06 0.04 20.4 V 10 0.02 0 0.2 0 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.20 109P0624M601 With pulse sensor DC Fan 60 mm sq. 109P0624W601 DC Airflow - Static Pressure Characteristics 5 0.4 10 15 Airflow 0.6 (m3/min) 20 (CFM) 0 0 0.1 0 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 70 Static pressure 0.25 0.20 0.15 0.10 60 53 V 50 48 V 40 43 V 30 20 0.05 10 0 0 0.2 0 5 0.4 10 Airflow 0.6 (m3/min) 15 20 (CFM) Dimensions (unit: mm) 0 20 -1 +1 60 0 4-o4.30.3 Mounting hole 500.3 (3) (5) 500.3 +1 60 0 Lead wire AWG24 UL 1007 +50 300 0 (10) Rotating direction Airflow direction 69 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 58 4-o4.5 500.3 3 58 500.3 o6 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 70 Resin finger guards page: p. 539 DC DC Fan DC Fan 60 mm sq. 60x60x25 mm San Ace 60 9G type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 90 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9G0612P4S001 12 10.2 to 13.8 9G0612P4H001 9G0624P4S001 24 20.4 to 27.6 48 36 to 72 9G0624P4H001 9G0648P4S001 PWM duty cycle* [%] 100 0 100 0 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.67 0.07 0.5 0.06 0.34 0.04 0.25 0.04 0.18 0.02 8.04 0.84 6.0 0.72 8.16 0.96 6.0 0.96 8.64 0.96 11000 3300 9500 2850 11000 3300 9500 2850 11000 3300 1.4 0.42 1.21 0.36 1.4 0.42 1.21 0.36 1.4 0.42 49.4 14.8 42.7 12.7 49.4 14.8 42.7 12.7 49.4 14.8 300 27 224 20.2 300 27 224 20.2 305 27.4 [inchHO] 1.2 0.11 0.9 0.08 1.2 0.11 0.9 0.08 1.22 0.11 SPL Operating temperature Expected life [dB (A)] [C] [h] 53 19 49 18 53 19 49 18 53 19 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 567 to 568. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) 12 VDC DC12 V PWM duty cycle PWM 100% 50% 0% 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 0 10 20 30 40 Airflow 50 (CFM) 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 13.8 V 12 V Fan speed Static pressure (inch H2O) (Pa) Static pressure 9G0612P4S001 PWM duty cycle 10.2 V 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 10 20 30 40 Airflow 50 (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 12000 11000 10000 9000 8000 7000 6000 5000 4000 -1 3000 3300 min 2000 1000 0 11000 min-1 100 (%) PWM duty cycle PWM 71 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 200 0.6 150 0.4 100 0.2 50 0 PWM duty cycle PWM 100% 50% 0% 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0 10 9G0624P4S001 20 30 Airflow 40 Static pressure 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0% 20 30 40 Airflow Static pressure 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 50 0% 0.2 0.4 0.6 0.8 1.0 1.2 1.4 20 30 Airflow Static pressure 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 40 72 Airflow 40 100 (%) PWM duty cycle PWM 50 (CFM) 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 27.6 V 24 V 20.4 V 0 10 20 30 40 50 Airflow Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 12000 11000 10000 9000 8000 7000 6000 5000 4000 -1 3000 3300 min 2000 1000 11000 min-1 100 (%) 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example PWM100% PWM duty cycle 100% 1.2 300 1.0 250 0.8 200 24 V 0.6 150 20.4 V 0.4 100 0.2 50 (min-1) 27.6 V 0 10 20 30 Airflow 40 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 10000 9000 8000 7000 6000 5000 4000 3000 2850 min-1 2000 1000 9500 min-1 100 (%) 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 (inch H2O) (Pa) 50% 0% 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 10 30 PWM duty cycle PWM 50 (CFM) Operating voltage range PWM duty cycle PWM 100% 0 400 50 (CFM) 48 VDC DC48 V 0 20 9500 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 400 1.6 0 (m3/min) PWM duty cycle 1.6 10 10000 9000 8000 7000 6000 5000 4000 3000 2850 min-1 2000 1000 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) (inch H2O) (Pa) 50% 9G0648P4S001 0 Operating voltage range 100% 10 50 0 PWM duty cycle PWM 0 0.2 (CFM) 24 VDC DC24 V 0 100 10.2 V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 300 0.4 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) PWM duty cycle 1.2 150 (inch H2O) (Pa) 50% 9G0624P4H001 0.6 12 V Operating voltage range 100% 10 200 (min-1) 13.8 V 0 PWM duty cycle PWM 0 0.8 50 (CFM) 24 VDC DC24 V 0 250 PWM100% PWM duty cycle 100% With pulse sensor with PWM control function (inch H2O) (Pa) 400 1.0 0 (m3/min) PWM duty cycle 1.6 300 Fan speed 0.8 1.2 Fan speed 250 Static pressure 1.0 (inch H2O) (Pa) 12 VDC DC12 V Static pressure 300 Static pressure 1.2 20 30 40 Airflow 50 (CFM) Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% Fan speed 9G0612P4H001 48 V/72 V 36 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 0 10 20 30 40 Airflow 50 (CFM) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 11000 min-1 3300 min-1 100 (%) PWM duty cycle PWM (With ribs) DC Dimensions (unit: mm) DC Fan 60 mm sq. 4-o4.50.3 Mounting hole 500.3 600.5 +50 300 0 (10) Lead wire AWG26 UL 1430 (3) 500.3 600.5 (3) 250.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 59 29.7 500.3 62 .7 59 500.3 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 73 DC Fan 60x60x25 mm San Ace 60 9R type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 90 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. 109R0605H401 109R0605F401 109R0605M401 109R0612J401 109R0612G401 109R0612D401 109R0612S401 109R0612H401 109R0612F401 109R0612M401 109R0624J401 109R0624G401 109R0624D401 109R0624S401 109R0624H401 109R0624F401 109R0624M401 109R0648J401 109R0648G401 109R0648H401 Rated voltage Operating voltage range Rated current Rated input [V] 5 [V] 4.5 to 5.5 10.8 to 13.2 10.2 to 13.8 12 6 to 13.8 7 to 13.8 21.6 to 26.4 20.4 to 27.6 24 48 12 to 27.6 14 to 27.6 43.2 to 52.8 43 to 53 40 to 53 Rated speed Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 0.34 0.2 0.13 0.47 0.24 0.21 0.17 0.11 0.09 0.06 0.24 0.13 0.12 0.08 0.06 0.05 0.04 0.12 0.07 0.04 1.7 1.0 0.65 5.64 2.88 2.52 2.04 1.32 1.08 0.72 5.76 3.12 2.88 1.92 1.44 1.2 0.96 5.76 3.36 1.92 3800 3200 2600 7600 5600 5150 4600 3800 3200 2600 7600 5600 5150 4600 3800 3200 2600 7600 5600 3800 0.53 0.44 0.36 1.06 0.78 0.72 0.65 0.53 0.44 0.36 1.06 0.78 0.72 0.65 0.53 0.44 0.36 1.06 0.78 0.53 18.7 15.5 12.7 37.1 27.5 25.4 23.0 18.7 15.5 12.7 37.1 27.5 25.4 23.0 18.7 15.5 12.7 37.1 27.5 18.7 40.2 29.4 19.6 155.0 87.3 73.5 56.8 40.1 29.4 19.6 155.0 87.3 73.5 56.8 40.2 29.4 19.6 155.0 87.3 40.2 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 564. Lock sensor 74 Max. airflow [A] PWM control [inchHO] 0.161 0.118 0.079 0.622 0.351 0.295 0.228 0.161 0.118 0.079 0.622 0.351 0.295 0.228 0.161 0.118 0.079 0.622 0.351 0.161 SPL Operating temperature Expected life [dB (A)] [C] 28 24 20 44 39 37 33 28 24 20 44 39 37 33 28 24 20 44 39 28 -20 to +70 -20 to +60 -20 to +70 -20 to +60 -20 to +70 [h] 60000/60C 40000/60C 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C 109R0605F401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 5.5 V 40 5V 30 4.5 V 20 0 5 10 15 20 Airflow 0.3 0.2 0.1 0 0.04 10 0 0.45 0.40 13.2 V 12 V 10.8 V 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 109R0612S401 60 0.10 0.05 0 13.8 V 60 Static pressure Static pressure 70 12 V 6V 30 20 0 0.2 5 109R0612M401 0.4 10 0.6 15 20 Airflow 0.8 25 10 0.02 5 0 0 0.7 Static pressure Static pressure 13.8 V 12 V 20 0.04 10 15 20 25 30 Airflow 7V 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) 20 (CFM) 0 0.04 10 0.02 5 0 0 5V 4.5 V 0.1 0.2 5 0.3 0.4 10 Airflow 0.5 (m3/min) 15 (CFM) With pulse sensor 100 0.3 80 12 V 60 10.2 V 0.2 40 0.1 0 20 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 5 109R0612F401 With pulse sensor 10 15 20 Airflow 25 (m3/min) 30 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.18 13.8 V 0.16 12 V 40 30 6V 10 40 13.8 V 0.14 0.12 12 V 30 0.10 0.08 6V 20 0.06 0.04 10 0.02 0 200 180 160 140 120 100 80 60 40 20 0 15 (CFM) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 10 15 Airflow 20 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 25 (CFM) 5 109R0624G401 With pulse sensor 10 15 Airflow 20 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 25 15 5 Operating voltage range 0.8 0.06 5.5 V 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 30 0.06 12 V 10.8 V 109R0624J401 With pulse sensor 20 Operating voltage range 13.2 V 20 0.05 0.08 109R0612D401 With pulse sensor 50 30 (CFM) (inch H2O) (Pa) 0.08 0.10 0 (m3/min) Operating voltage range 0.10 0.15 10 0 0.12 0.20 25 (CFM) Operating voltage range (inch H2O) (Pa) 40 Airflow 0.10 13.8 V 109R0612H401 With pulse sensor 80 0.15 20 30 0.4 0 (inch H2O) (Pa) 50 15 0.12 (inch H2O) (Pa) 110 100 90 80 70 60 50 40 30 20 10 0 (CFM) Operating voltage range 0.20 10 (inch H2O) (Pa) 200 180 160 140 120 100 80 60 40 20 0 Airflow 0.25 5 Operating voltage range 0 5 10 15 20 25 30 35 40 45 0.30 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 Static pressure Static pressure 0.4 4.5 V 0.06 109R0612G401 With pulse sensor (inch H2O) (Pa) 0.5 5V 20 25 (CFM) Operating voltage range 0.6 0.08 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 109R0612J401 0.7 0.10 0.02 0 0.8 5.5 V Static pressure 0 10 30 Static pressure 0.05 0.12 Static pressure 50 26.4 V Static pressure 0.10 (inch H2O) (Pa) 40 0.14 Static pressure Static pressure 0.15 0.16 With pulse sensor Operating voltage range (inch H2O) (Pa) 60 0.20 109R0605M401 With pulse sensor DC Fan 60 mm sq. 109R0605H401 DC Airflow - Static Pressure Characteristics 24 V 21.6 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 5 10 15 20 25 30 35 40 45 Airflow (CFM) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 120 110 100 90 80 70 60 50 40 30 20 10 0 27.6 V 24 V 20.4 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 5 10 15 20 25 30 Airflow (CFM) 75 Airflow - Static Pressure Characteristics 109R0624S401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 80 60 100 0.30 0.3 80 Static pressure Static pressure 27.6 V 24 V 60 0.2 12 V 40 0.1 0 20 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 5 109R0624F401 10 15 20 Airflow 25 0.12 40 27.6 V 24 V 30 12 V 20 0.06 10 0.02 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 5 109R0648G401 10 15 Airflow 20 0 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0.4 10 0.6 15 20 0.8 60 Static pressure (inch H2O) (Pa) 53 V 48 V 43 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0 5 (m3/min) 10 15 20 25 30 35 (CFM) Airflow 0.15 0.10 25 Airflow 0 24 V 40 30 12 V 20 0.05 10 0 30 (CFM) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 109R0648J401 With pulse sensor 10 15 Airflow 20 25 (CFM) With pulse sensor Operating voltage range 0.8 27.6 V 0.7 24 V 14 V 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.2 5 0.3 0.4 10 Airflow 15 0.5 (m3/min) 20 (CFM) With pulse sensor 53 V 50 48 V 40 30 40 V 20 0.05 0.10 0 (m3/min) Operating voltage range 0.20 0.15 27.6 V 50 (inch H2O) (Pa) 109R0648H401 With pulse sensor 120 110 100 90 80 70 60 50 40 30 20 10 0 Static pressure 5 0 (inch H2O) (Pa) 76 0.2 30 (CFM) Operating voltage range 0.20 10 Operating voltage range Static pressure Static pressure 20 (inch H2O) (Pa) 0.10 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 12 V 30 109R0624M401 With pulse sensor 0.14 0 24 V 0 0.18 0.04 40 30 (CFM) (inch H2O) (Pa) 0.08 0.15 0 (m3/min) Operating voltage range 0.12 50 0.10 27.6 V 60 0.20 0.05 0 0.16 0.25 70 With pulse sensor Operating voltage range Static pressure 0.4 109R0624H401 With pulse sensor Static pressure 109R0624D401 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 0 200 180 160 140 120 100 80 60 40 20 0 52.8 V 48 V 43.2 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 5 10 15 20 25 30 35 40 45 Airflow (CFM) +1 60 0 4-o4.30.3 Mounting hole 500.3 DC (With ribs) 250.5 (3) DC Fan 60 mm sq. Dimensions (unit: mm) (3) +50 300 0 500.3 +1 60 0 Lead wire AWG24 UL 1007 (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 77 DC Fan 60x60x25 mm San Cooler 60 9A type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 80 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9A0612G401 9 A 0 6 1 2 S 4 01 9A0612H401 9 A 0 6 1 2 F 4 01 9A0612M401 9A0624G401 9 A 0 6 2 4 S 4 01 9A0624H401 9 A 0 6 2 4 F 4 01 9A0624M401 12 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 6 to 13.2 0.24 0.17 0.11 0.09 0.06 0.13 0.08 0.06 0.05 0.04 2.88 2.04 1.32 1.08 0.72 3.12 1.92 1.44 1.2 0.96 5600 4600 3800 3200 2600 5600 4600 3800 3200 2600 0.78 0.65 0.53 0.44 0.36 0.78 0.65 0.53 0.44 0.36 27.6 23.0 18.7 15.5 12.7 27.6 23.0 18.7 15.5 12.7 87.3 56.8 40.2 29.4 19.6 87.3 56.8 40.2 29.4 19.6 6 to 13.8 7 to 13.8 12 to 27.6 24 Rated speed [V] 12 to 27.6 14 to 27.6 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 39 33 28 24 20 39 33 28 24 20 -20 to +60 30000/60C -20 to +70 40000/60C -20 to +60 30000/60C -20 to +70 40000/60C 0.351 0.228 0.161 0.118 0.079 0.351 0.228 0.161 0.118 0.079 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 565. Lock sensor PWM control Airflow - Static Pressure Characteristics 9A0612S401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 110 100 90 80 70 60 50 40 30 20 10 0 80 Static pressure 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 0.30 13.2 V 12 V 6V 5 10 15 20 25 30 Airflow 0.25 0.15 40 0.10 (CFM) 0 Operating voltage range 0.25 13.8 V 60 50 With pulse sensor (inch H2O) (Pa) 70 0.20 0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 78 Static pressure 0.45 9A0612H401 With pulse sensor Static pressure 9A0612G401 12 V 6V 30 20 0.20 0.15 0.10 0.2 0 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow (CFM) 13.8 V 50 40 12 V 30 6V 20 0.05 10 0 60 0 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 9A0612M401 With pulse sensor Operating voltage range Operating voltage range 13.8 V 30 0.10 0.08 12 V 20 0.06 0.04 10 6V 0.02 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 9A0624S401 5 10 15 20 Airflow 0.10 0.05 0 0.04 10 0.02 5 0 0 13.8 V 12 V 7V 0.1 0 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) 24 V 12 V 30 20 0.20 0.15 0.10 0.05 0 0.2 0 9A0624M401 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow (CFM) 0 0.20 0.15 0.10 0.05 0 120 110 100 90 80 70 60 50 40 30 20 10 0 27.6 V 24 V 12 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 9A0624F401 With pulse sensor 5 10 15 20 25 30 Airflow (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.16 60 27.6 V 50 40 24 V 30 40 0.14 12 V 20 10 0.45 0.40 0.35 0.30 0.25 20 (CFM) Operating voltage range Static pressure Static pressure 40 0.06 15 27.6 V 60 0.15 20 0.25 70 50 0.08 (inch H2O) (Pa) 80 0.20 25 (inch H2O) (Pa) 9A0624H401 With pulse sensor (inch H2O) (Pa) 0.25 0.10 (CFM) Operating voltage range 0.30 30 Static pressure 0.12 Static pressure Static pressure 0.14 0.12 Static pressure 40 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.16 9A0624G401 With pulse sensor DC Fan 60 mm sq. 9A0612F401 DC Airflow - Static Pressure Characteristics 10 0.12 27.6 V 30 0.10 0.08 24 V 20 0.06 0.04 10 12 V 0.02 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 5 10 15 Airflow 20 (CFM) With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 27.6 V 24 V 14 V 0.1 0 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) 20 (CFM) 79 Dimensions (unit: mm) (With ribs) +1 60 0 250.5 4-o4.30.3 Mounting hole Lead wire AWG24 UL 1007 +50 300 0 500.3 +1 60 0 500.3 (3) (3) (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 4-o4.5 500.3 59 500.3 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 80 Resin finger guards page: p. 539 DC DC Fan DC Fan 60 mm sq. 60x60x25 mm San Ace 60 9S type Silent Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 55 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9S0612S401 9S0612H401 9S0612F401 9S0612M401 [V] 5.0 to 13.8 12 6.0 to 13.8 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.2 0.11 0.08 0.07 2.4 1.32 0.96 0.84 5000 3900 3300 2700 0.74 0.58 0.49 0.4 26.1 20.5 17.3 14.1 65.7 40.0 29.3 19.7 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 31 24 20 16 -10 to +70 40000/60C 0.26 0.16 0.12 0.08 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 577. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9S0612S401 9S0612H401 With pulse sensor Operating voltage range 100 80 13.8 V 60 0.2 0.1 0 (inch H2O) (Pa) 12 V 40 20 5V 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 10 20 30 Airflow 40 (CFM) 0.20 0.15 0.10 0.05 0 0.25 60 13.8 V 50 Static pressure 0.3 120 Static pressure Static pressure 0.4 0.25 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.5 9S0612F401 With pulse sensor Operating voltage range 12 V 40 5V 30 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 0.20 0.15 0.10 0.05 0 60 13.8 V 50 12 V 40 6V 30 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) 81 Airflow - Static Pressure Characteristics 9S0612M401 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.125 30 13.8 V 25 0.100 12 V 20 0.075 6V 15 0.050 10 0.025 5 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 Dimensions (unit: mm) 25 (CFM) (With ribs) 250.5 4-o4.30.3 Mounting hole (3) (3) +50 300 0 500.3 600.5 Lead wire AWG24 UL 1007 (10) 500.3 600.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 4-o4.5 59 500.3 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 82 Resin finger guards page: p. 539 DC DC Fan DC Fan 60 mm sq. 60x60x38 mm San Ace 60 9HV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 135 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 12 9HV0612P1J001 PWM duty cycle* [%] 10.8 to 12.6 Rated current Rated input Rated speed 100 20 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.7 0.17 32.4 2.04 21700 5300 1.88 0.43 66.4 15.2 1750 102 [inchHO] 7.0 0.41 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 68 34 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV0612P1J001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) Static pressure 6 5 1600 1200 1000 3 800 2 1 0 6 PWM PWM duty cycle 100% 1400 4 7 Static pressure 7 (inch H2O) (Pa) 12 VDC DC12 V 1800 600 400 200 0 0.4 1000 3 800 1 20% 0.8 1.2 1.6 0 2.0 (m /min) 3 0 10 20 30 40 50 60 70 (CFM) 10.8 V 600 400 200 0 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow Airflow Dimensions (unit: mm) 1400 4 2 12 V/12.6 V 1600 1200 (min-1) PWM100% PWM duty cycle 100% 1800 5 PWM duty - Speed characteristics example Fan speed PWM duty cycle 22000 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 21700 min-1 100 (%) PWM duty cycle PWM (With ribs) 4-o4.50.3 Mounting hole 500.3 600.5 +50 300 0 (10) Lead wire AWG24 UL 1430 40.3 500.3 600.5 Rotating direction 40.3 380.5 Airflow direction 83 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 59 29.7 500.3 62 .7 59 500.3 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 84 Resin finger guards page: p. 539 DC DC Fan DC Fan 60 mm sq. 60x60x38 mm San Ace 60 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 130 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 10.8 to 12.6 9GA0612P1J03** 9GA0612P1K03** 12 10.8 to 13.2 9GA0612P1H03** 9GA0612P1K60 21.6 to 25.2 9GA0624P1J03** 24 21.6 to 26.4 9GA0624P1K03** * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 20 100 20 100 0 100 20 100 20 Max. airflow [A] [W] [min-1] [m/min] [CFM] 1.5 0.1 0.95 0.1 0.55 0.06 0.95 0.05 0.75 0.1 0.5 0.06 18.0 1.2 11.4 1.2 6.6 0.72 11.4 0.6 18.0 2.4 12 1.44 17500 4000 14800 4000 11500 2600 14800 1480 17500 6200 14800 5000 1.75 0.4 1.5 0.4 1.15 0.27 1.5 0.134 1.75 0.63 1.5 0.5 62 14 53 14 40 9.5 53 4.7 62 22 53.0 17.7 Max. static pressure [Pa] 820 43 600 43 375 20 675 8.3 820 104 600 70 [inchHO] 3.3 0.17 2.4 0.17 1.5 0.08 2.7 0.03 3.3 0.42 2.4 0.28 SPL Operating temperature Expected life [dB (A)] [C] [h] 63 24 59 24 52 19 59 16 63 35 59 28 -20 to +60 -20 to +70 -20 to +60 40000/60C (70000/40C) -20 to +60 -20 to +70 ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 570 to 571. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 12 VDC DC12 V 3.5 900 800 3.0 700 2.5 600 PWM PWM duty cycle 100% Static pressure Static pressure (inch H2O) (Pa) 2.0 500 1.5 400 300 1.0 200 0.5 100 0 60% 20% 0 0.4 0.8 1.2 1.6 2.0 (m /min) 3 0 10 20 30 40 50 60 70 Airflow (CFM) 3.5 900 800 3.0 700 2.5 600 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 18000 12.6 V 12 V 10.8 V 2.0 500 1.5 400 300 1.0 200 0.5 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 17500 min-1 16000 Fan speed 9GA0612P1J03 14000 12000 10000 8000 6000 4000 2000 0 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) 0 100 (%) PWM duty cycle PWM 85 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0612P1K03 With pulse sensor with PWM control function PWM duty cycle Operating voltage range 100% 400 300 60% 200 0 0 0.4 10 0.8 20 30 1.2 40 Airflow 9GA0612P1H03 100% 200 0 60% 0 0.4 10 9GA0612P1K60 0.8 1.2 20 30 40 50 Static pressure Static pressure 0% 0.4 9GA0624P1J03 0.8 20 30 1.2 40 500 1.5 400 1.0 0.5 0 200 100 0 30 1.2 40 Airflow 1.6 (m3/min) 50 8000 6000 4000 100 (%) 0 PWM duty cycle PWM (CFM) 1.0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 16000 200 14800 min-1 12000 10000 8000 6000 4000 0.5 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 13.2 V/12 V 10.8 V 300 0 (inch H2O) (Pa) 3.5 PWM duty cycle PWM 3.0 100% 60% 20% 0.4 0.8 20 2000 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 1480 min-1 100 (%) 0 PWM duty cycle PWM (CFM) Operating voltage range 24 VDC DC24 V 300 0.4 10 400 (CFM) 600 2.0 11500 min-1 10000 With pulse sensor with PWM control function 900 700 1.5 0 Static pressure Static pressure 2.5 0 2.0 500 1.6 (m3/min) 50 Airflow (inch H2O) (Pa) 800 14000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 2000 2.5 600 50% 10 (min-1) 100 700 PWM duty cycle 3.0 100 (%) PWM duty - Speed characteristics example 10.8 V (inch H2O) (Pa) 300 0 0 PWM duty cycle PWM (CFM) Operating voltage range 400 0 3.5 0.5 0 2.0 500 0 12 V (CFM) PWM PWM duty cycle 100% 200 300 200 0 12 VDC DC12 V 0.5 100 6000 With pulse sensor with PWM control function 700 2.5 600 13.2 V Airflow (inch H2O) (Pa) 1.0 8000 12000 400 1.0 1.6 (m3/min) PWM duty cycle 1.5 1.5 20% 0 0.8 1.2 1.6 2.0 (m3/min) PWM duty cycle 100% PWM100% 2.0 500 Static pressure Static pressure (inch H2O) (Pa) PWM PWM duty cycle 100 0.4 Airflow 1.0 0.5 10000 2000 0 10 20 30 40 50 60 70 12 VDCV DC12 300 0 12000 4000 Operating voltage range 2.0 500 0.8 2.5 1.2 1.6 2.0 (m3/min) Airflow (CFM) 900 700 600 500 1.5 400 1.0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 18000 16000 800 2.0 0.5 0 10 20 30 40 50 60 70 86 0 14800 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 400 200 (CFM) PWM duty cycle 1.5 300 0.5 100 1.6 (m3/min) 50 10.8 V Fan speed 0 20% 1.0 400 Fan speed 0.5 100 13.2 V 12 V 2.0 500 1.5 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 25.2 V 24 V 21.6 V 300 17500 min-1 12000 10000 8000 6000 200 4000 100 2000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 14000 Fan speed 1.0 16000 2.5 600 PWM PWM duty cycle 2.0 500 (min-1) PWM duty cycle 100% PWM100% 700 Static pressure Static pressure 2.5 600 1.5 (inch H2O) (Pa) 12 VDC DC12 V 700 Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function PWM duty cycle Operating voltage range 700 1.5 1.0 0.5 0 700 100% 2.0 500 400 300 60% 200 20% 100 0 0.4 0 10 0.8 20 30 1.2 40 Airflow Dimensions (unit: mm) 16000 14000 1.5 1.0 400 21.6 V 300 200 0 14800 min-1 10000 8000 6000 4000 0.5 100 2000 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 100 (%) PWM duty cycle PWM 0 10 20 30 40 50 60 70 (CFM) (CFM) Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 12000 26.4 V 24 V 2.0 500 0 1.6 (m3/min) 50 (min-1) PWM duty cycle 100% PWM100% 2.5 600 PWM duty cycle PWM 600 Static pressure Static pressure 2.5 (inch H2O) (Pa) 24 VDC DC24 V Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example Airflow (With ribs) 4-o4.50.3 Mounting hole +50 300 0 500.3 600.5 (10) Lead wire AWG24 UL 1007 (4) (4) 500.3 380.5 600.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 4-o4.5 59 29.7 500.3 62 .7 500.3 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 87 DC Fan 60 mm sq. 9GA0624P1K03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example DC Fan 60x60x38 mm San Ace 60 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 130 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GV0612P1G03 9GV0612P1H03 12 8.0 to 13.8 9GV0612P1M03 10.8 to 13.8 9 G V 0 6 1 2 P 1 L 01 * * 9GV0624P1G03 24 20.4 to 27.6 48 38 to 57 9GV0624P1M03** 9GV0648P1H03 * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 0 100 100 0 100 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.8 0.12 2.0 0.1 1.5 0.08 0.7 1.4 0.12 0.73 0.5 0.08 33.6 1.5 24.0 1.2 18.0 1.0 8.4 33.6 2.88 17.52 24 3.84 16000 3100 14500 2700 13000 2500 10000 16000 6000 13000 14500 6000 2.37 0.44 2.15 0.4 1.93 0.38 1.49 2.37 0.89 1.93 2.15 0.89 84 15 76 14 68 13 52.6 84 31 68.0 76 31 751 26 617 21 496 18 293 751 105 496 617 105 [inchHO] 3.02 0.1 2.48 0.09 1.99 0.07 1.17 3.02 0.42 1.99 2.48 0.42 SPL Operating temperature Expected life [dB (A)] [C] [h] 66 25 63 22 60 19 52 66 38 60 63 38 -20 to +70 40000/60C ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 574. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range DC12 12 VDC DC12 VV 900 3.6 900 3.6 800 3.2 800 3.2 700 2.8 700 2.8 600 2.4 600 2.4 500 2.0 500 2.0 1.6 400 1.6 400 300 1.2 300 1.2 200 0.8 200 0.8 100 0.4 100 0.4 00 00 PWM PWM duty cycle PWM 100% 100% 50% 50% 0% 0% 3 3 /min) /min) 0.4 0.4 0.8 0.81.2 1.21.6 1.62.0 2.02.4 2.42.8 2.8(m(m (CFM) 0010 1020203030404050506060707080809090100 100(CFM) Airflow 88 (inch H2O) (Pa) (inch H2O) (Pa) 900 3.63.6 900 800 3.23.2 800 (min-1) PWM duty cycle 100% PWM100% PWM100% 18000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16000 min-1 16000 700 2.82.8 700 600 2.42.4 600 13.8 13.8 VV 500 2.02.0 500 400 1.61.6 400 1.21.2 300 300 1212 VV 8V 8V 0.80.8 200 200 0.40.4 100 100 00 PWM duty - Speed characteristics example 14000 Fan speed Static pressure 2O) (Pa) (inchHH2O) (Pa) (inch PWM duty cycle Static pressure 9GV0612P1G03 12000 10000 8000 6000 4000 2000 0 0 0.40.40.80.8 3 /min) (m3(m /min) 1.21.21.61.6 2.02.0 2.42.4 2.82.8 (CFM) (CFM) 50 50 60 60 2020 3030 70 70 80 80 0 10 40 40 90 100 90 100 0 10 Airflow 0 3100 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (Pa) (Pa) (inch (inch H2O) H2O) 3.63.6 900 900 3.23.2 800 800 2.82.8 700 700 2.82.8 700 700 500 2.02.0 500 PWM duty cycle PWM PWM 100% 100% 1.61.6 400 400 0.80.8 200 200 00 0 0 0.40.40.80.81.21.21.61.62.02.02.42.42.82.8(m(m 3 3 /min) /min) Airflow (inch (inch H2O) H2O)(Pa) (Pa) 12 VDC DC12 DC12 V V 3.63.6 900 900 00 (inch H2O) (Pa) 1.6 400 1.6 400 1.4 350 1.4 350 1.2 300 1.2 300 1.0 250 1.0 250 0.8 200 0.8 200 0.6 150 0.6 150 0.4 100 0.4 100 0.2 50 0.2 50 0 0 0 0 PWM duty cycle PWM 100% 50% 0.8 1.2 1.6 2.0 (m3/min) Airflow 1.2 300 0.8 200 0.4 100 0 0 100 (%) 0 (min-1) PWM duty cycle 100% PWM100% 13.8 V 12 V 10.8 V 0.4 0.8 1.2 1.6 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 10000 min-1 100 (%) 0 2.0 (m3/min) PWM duty cycle PWM Airflow 24 VDC DC24 V PWM duty cycle PWM 100% 50% 0% 0.4 0.8 1.2 1.6 2.0 2.4 2.8 (m3/min) 0 10 20 30 40 50 60 70 80 90100 (CFM) Airflow (inch H2O) (Pa) Static pressure 400 2500 min-1 PWM duty - Speed characteristics example Operating voltage range (inch H2O) (Pa) 1.6 4000 With pulse sensor with PWM control function PWM duty cycle 500 6000 PWM duty cycle PWM 0 10 20 30 40 50 60 70 (CFM) 0 10 20 30 40 50 60 70 (CFM) 2.0 8000 Airflow Static pressure Static pressure 0 0 0.40.40.80.81.21.21.61.62.02.02.42.42.82.8(m(m 3 3 /min) /min) (CFM) (CFM) 7070 8080 100 0 01010 2020 3030 4040 5050 6060 9090 100 12 VDC DC12 V 600 10000 2000 Operating voltage range (inch H2O) (Pa) 700 13000 min-1 With pulse sensor with PWM control function PWM duty cycle 9GV0624P1G03 88 VV 0.40.4 100 100 Airflow 0.4 1212 VV 1.21.2 300 300 0.80.8 200 200 50% 50% Fan speed Static pressure Static pressure 1.61.6 400 400 100 0 01010 4040 100 2020 3030 9090 5050 6060 7070 8080 (CFM) (CFM) 2.4 13.8 13.8 VV 500 2.02.0 500 PWM duty cycle PWM PWM 100% 100% 0.40.4 100 100 0% 0% 00 00 3 3 0.40.40.80.81.21.21.61.62.02.02.42.42.82.8(m(m /min) /min) 2.8 14000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 12000 2.42.4 600 600 500 2.02.0 500 800 (min-1) 2.82.8 700 700 2.82.8 700 700 2.42.4 600 600 3.2 PWM duty - Speed characteristics example 3.23.2 800 800 9GV0612P1L01 100 (%) 0 duty cycle PWMPWM PWM duty cycle 100% PWM100% PWM100% 3.63.6 900 900 3.23.2 800 800 0.80.8 200 200 2700 min-1 With pulse sensor with PWM control function (inch (inch H2O) H2O) (Pa) (Pa) Static pressure 0 0 0.40.40.80.81.21.21.61.62.02.02.42.42.82.8(m(m 3 3 /min) /min) Operating voltage range 1.21.2 300 300 6000 Airflow PWM duty cycle 1.61.6 400 400 8000 4000 (CFM) (CFM) 2020 3030 5050 6060 7070 8080 9090 0 01010 4040 100 100 (CFM) (CFM) 7070 8080 0 01010 4040 100 2020 3030 9090 100 5050 6060 10000 2000 0.40.4 100 100 0% 0% 9GV0612P1M03 8 8V V Fan speed 00 1212V V 1.61.6 400 400 4.0 1000 3.6 900 3.2 800 2.8 700 2.4 600 2.0 500 1.6 400 1.2 300 0.8 200 0.4 100 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 16000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 16000 min-1 14000 27.6 V 24 V 12000 Fan speed 0.40.4 100 100 2.02.0 500 500 0.80.8 200 200 50% 50% 14500 min-1 12000 13.8 13.8V V 1.21.2 300 300 1.21.2 300 300 16000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 2.42.4 600 600 2.42.4 600 600 3.63.6 900 900 3.23.2 800 800 (min-1) PWM duty cycle 100% PWM100% PWM100% Static pressure Static pressure (Pa) (Pa) (inch (inch H2O) H2O) 12 VDC DC12 DC12 V V PWM duty - Speed characteristics example Fan speed PWM duty cycle 20.4 V 10000 8000 6000 6000 min-1 4000 2000 0.4 0.8 1.2 1.6 2.0 2.4 2.8 (m3/min) 0 10 20 30 40 50 60 70 80 90100 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 89 DC Fan 60 mm sq. 9GV0612P1H03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GV0624P1M03 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 2.0 500 2.4 600 Static pressure 2.4 600 PWM PWM duty cycle 100% 1.6 400 1.2 300 0.8 200 50% 0 9GV0648P1H03 500 1.6 400 1.2 300 0.8 200 0.4 100 0 0.4 0.8 1.2 1.6 2.0 2.4 (m3/min) (inch H2O) (Pa) PWM duty cycle PWM 100% 50% 0% 0.4 0.8 1.2 1.6 2.0 2.4 (m3/min) Airflow Dimensions (unit: mm) 4000 100 (%) 3.2 800 2.8 700 2.4 600 2.0 500 1.6 400 1.2 300 0.8 200 0.4 100 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 16000 38 V 10000 8000 6000 6000 min-1 4000 2000 0.4 0.8 1.2 1.6 2.0 2.4 2.8 0 (m3/min) Airflow (10) Lead wire AWG26 UL 1007 (Model no.: 9GV0612P1G03 only) UL 1430 9GV0612P1G03 (4) (4) 600.5 380.5 Rotating direction Airflow direction 100 (%) duty cycle PWMPWM +50 300 0 500.3 14500 min-1 12000 48 V (With ribs) 500.3 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 14000 57 V 4-o4.50.3 Mounting hole 600.5 6000 0 0 10 20 30 40 50 60 70 80 90 100 (CFM) 0 10 20 30 40 50 60 70 80 90 (CFM) 90 8000 PWM duty cycle PWM (CFM) Operating voltage range 48 VDC DC48 V 0 0 10000 2000 0 10 20 30 40 50 60 70 80 Static pressure Static pressure 2.0 0.8 200 0 13000 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 600 20.4 V 1.2 300 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 12000 Airflow PWM duty cycle 700 24 V (CFM) Airflow 2.4 27.6 V 1.6 400 0.4 0.8 1.2 1.6 2.0 2.4 (m3/min) 0 10 20 30 40 50 60 70 80 2.8 2.0 500 14000 0.4 100 0.4 100 0 (min-1) PWM duty cycle 100% PWM100% Fan speed Static pressure (inch H2O) (Pa) 24 VDC DC24 V PWM duty - Speed characteristics example Fan speed PWM duty cycle DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side DC Fan 60 mm sq. 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 91 DC Fan 60x60x38 mm San Ace 60 9G type (Ribless model depicted) General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 110 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9G0612G101 9G0612S101 9G0624G101 9G0624S101 9G0624H101 9G0648G101 9G0648S101 [V] 12 7.0 to 13.8 24 14.0 to 27.6 48 28 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.54 1.36 0.85 0.7 0.57 0.35 0.29 18.5 16.3 20.4 16.8 13.68 16.8 13.9 11800 10800 11800 10800 9800 11800 10800 1.84 1.7 1.84 1.7 1.54 1.84 1.7 65 60 65 60 54.4 65 60 435 370 435 370 304.6 435 370 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 58 56 58 56 54 58 56 -20 to +70 40000/60C 1.747 1.486 1.747 1.486 1.223 1.747 1.486 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 567 to 568. Lock sensor PWM control Airflow - Static Pressure Characteristics 9G0612G101 9G0612S101 With pulse sensor Operating voltage range Operating voltage range 12 V 7V 0.4 0.8 1.2 1.6 2.0 2.4 (m3/min) 0 92 20 40 60 Airflow 80 (CFM) 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (inch H2O) (Pa) 13.8 V Static pressure 13.8 V 1.8 With pulse sensor Operating voltage range (inch H2O) (Pa) 550 500 450 400 350 300 250 200 150 100 50 0 Static pressure Static pressure (inch H2O) (Pa) 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 9G0624G101 With pulse sensor 12 V 7V 0.4 0 0.8 20 1.2 40 Airflow 1.6 60 2.0 (m3/min) 80 (CFM) 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 550 500 450 400 350 300 250 200 150 100 50 0 27.6 V 24 V 14 V 0.4 0.8 1.2 1.6 2.0 2.4 (m3/min) 0 20 40 60 Airflow 80 (CFM) 9G0624H101 With pulse sensor Operating voltage range Operating voltage range 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 1.6 400 24 V 14 V 0.4 0 9G0648S101 0.8 20 1.2 40 Airflow 1.6 2.0 60 1.4 350 Static pressure 1.6 (inch H2O) (Pa) 1.8 450 Static pressure Static pressure 450 27.6 V 1.2 300 1.0 250 0.8 200 24 V 0.6 150 14 V 0.4 100 0.2 50 0 0 (m3/min) 80 (CFM) 0.4 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 1.8 9G0648G101 With pulse sensor DC Fan 60 mm sq. 9G0624S101 DC Airflow - Static Pressure Characteristics 0.8 1.2 1.6 2.0 (m3/min) 10 20 30 40 50 60 70 (CFM) Airflow 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 550 500 450 400 350 300 250 200 150 100 50 0 55.2 V 48 V 28 V 0.4 0.8 1.2 1.6 2.0 2.4 (m3/min) 0 20 40 60 Airflow 80 (CFM) With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 55.2 V 48 V 28 V 0.4 0 0.8 20 1.2 40 Airflow 1.6 2.0 60 Dimensions (unit: mm) +1 60 0 500.3 (m3/min) 80 (CFM) (With ribs) 4-o4.30.3 Mounting hole 380.5 (4) (4) Lead wire AWG24 UL 1007 +1 60 0 500.3 +50 300 0 (10) Rotating direction Airflow direction 93 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 94 Resin finger guards page: p. 539 DC DC Fan DC Fan 70 mm sq. 70x70x38 mm San Ace 70 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Brown Control Mass ...................................................... 170 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range PWM duty Rated current Rated input Rated speed Model no. cycle* [%] [A] [W] [min-1] [m/min] [CFM] 10.8 to 13.2 100 0 100 0 2.6 0.16 1.1 0.07 31.2 1.92 13.2 0.84 16500 4400 12000 2500 2.65 0.7 1.92 0.4 93.6 24.7 67.8 14.1 9GA0712P1G001 12 Max. airflow [V] [V] 9GA0712P1H001 Max. static pressure [Pa] 860 61 455 20 [inchHO] 3.45 0.24 1.83 0.08 SPL Operating temperature Expected life [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 65 30 57 19 * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) Static pressure 3.5 3.0 2.5 1000 4.0 3.5 PWM PWM duty cycle 100% 800 Static pressure 4.0 (inch H2O) (Pa) DC12 V 12 VDC 600 2.0 1.5 1.0 0.5 0 400 200 50% 0 1 20 9GA0712P1H001 2 40 60 Airflow 100 2.0 0 Static pressure Static pressure 0.5 PWM duty cycle PWM 100% 300 100 0 0 50% 1.5 20 400 12000 10000 8000 6000 4000 200 2000 0 1 20 2 40 60 Airflow 0 3 (m3/min) 80 100 (%) PWM duty cycle PWM 100 (CFM) 0.5 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 500 14000 12000 13.2 V 400 12 V 300 1.0 0% 0.5 10.8 V 600 500 200 600 (inch H2O) (Pa) 12 VDC DC12 V 400 14000 12 V 0 (CFM) 16500 min-1 16000 800 Operating voltage range 600 1.0 1.0 18000 13.2 V DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz With pulse sensor with PWM control function (inch H2O) (Pa) 1.5 1.5 (min-1) PWM duty cycle 100% PWM100% 1000 2.0 0 3 (m3/min) 80 PWM duty cycle 2.0 2.5 0.5 0% 0 3.0 PWM duty - Speed characteristics example Fan speed PWM duty cycle Fan speed 9GA0712P1G001 10.8 V 200 100 0 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 12000 min-1 10000 8000 6000 4000 2000 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) duty cycle PWMPWM 95 Dimensions (unit: mm) (With ribs) 700.5 61.50.3 4-o4.50.3 Mounting hole 300 +50 0 (10) 61.50.3 700.5 (4) Lead wire AWG24 UL 1430 (4) 380.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 61.5 61.5 4-o4.5 69 69 Options Finger guards Model no.: 109-1128 96 61.5 69 69 61.5 o7 o7 4 8 4-o4.5 page: p. 532 DC DC Fan DC Fan 80 mm sq. 80x80x15 mm San Ace 80 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 65 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9GA0812P7G001 9GA0812P7S001 9GA0824P7G001 9GA0824P7S001 [V] 12 10.2 to 13.8 24 20.4 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 100 100 100 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.29 0.17 0.13 0.08 3.48 2.04 3.12 1.92 6100 5000 6100 5000 1.44 1.18 1.44 1.18 50.9 41.7 50.9 41.7 84.0 56.4 84.0 56.4 [inchHO] 0.34 0.23 0.34 0.23 SPL Operating temperature Expected life [dB (A)] [C] [h] 41 37 41 37 -20 to +70 40000/60C (70000/40C) SPL Operating temperature Expected life [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 571 to 572. Lock sensor The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Model no. 9GA0812H70 01 9GA0824H70 01 Max. airflow [V] [V] [A] [W] [min-1] [m/min] 12 24 6 to 13.2 12 to 26.4 0.09 0.05 1.08 1.2 3800 3800 0.89 0.89 [CFM] 31.4 31.4 Max. static pressure [Pa] 32.6 32.6 [inchHO] 0.13 0.13 29 29 The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 571. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0812P7G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.2 0.1 0 PWM PWM duty cycle 100% 80 60 40 50% 20 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 10 20 30 40 Airflow 50 (CFM) 0.2 0.1 0 6000 13.8 V 0.4 100 0.3 (min-1) PWM duty cycle 100% PWM100% 0.5 120 Static pressure Static pressure 0.4 100 0.3 (inch H2O) (Pa) 12 VDC DC12 V 0.5 120 PWM duty - Speed characteristics example 80 10.2 V 60 40 6100 min-1 4000 3000 2000 1000 20 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 Voltage: 12 VDC DC12 V PWM frequency: kHz 25 kHz PWM25 5000 12 V Fan speed PWM duty cycle 10 20 30 40 Airflow 50 (CFM) 0 100 (%) PWM PWM duty cycle 97 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0812P7S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.3 PWM PWM duty cycle 100% 40 0.1 0 50% 20 0 0 10 20 30 Airflow 9GA0824P7G001 40 50 Static pressure Static pressure 60 40 50% 20 10 20 30 40 50 Airflow PWM PWM duty cycle 100% 50% 10 9GA0812H7001 20 30 Airflow 40 13.2 V Static pressure Static pressure 98 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6100 min-1 5000 40 4000 3000 2000 1000 20 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 10 20 30 40 50 Airflow 0 100 (%) PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 80 6000 27.6 V 5000 24 V 20.4 V 40 0.1 20 0 12 V 6V 0.2 0.4 10 0.6 20 Airflow 0.8 30 1.0 (m3/min) (CFM) 0.15 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 10 20 30 Airflow 40 50 (CFM) With pulse sensor 50 40 26.4 V 30 24 V 0.1 20 0.05 0 12 V 10 0 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 min-1 4000 3000 2000 1000 Operating voltage range 20 0 6000 20.4 V 0.2 0.2 40 0 (min-1) (inch H2O) (Pa) 30 0 PWM duty - Speed characteristics example 60 0 50 10 100 (%) 0 24 V 9GA0824H7001 With pulse sensor 0.1 0.05 2000 PWM duty cycle PWM 50 (CFM) 27.6 V 60 50 (CFM) (inch H2O) (Pa) 0.15 0.1 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) Operating voltage range 0.2 0.2 0.3 20 0 40 PWM duty cycle 100% PWM100% 80 0 Static pressure Static pressure 80 0 Airflow (inch H2O) (Pa) 40 0 30 Operating voltage range 24 VDC DC24 V 0.2 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.1 0.3 (CFM) PWM duty cycle 60 20 0.4 100 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 9GA0824P7S001 0.3 10 0.5 120 PWM PWM duty cycle 100% 80 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) (inch H2O) (Pa) 24 VDC DC24 V 0.4 100 0 0 4000 1000 Operating voltage range 0.5 120 0.1 20 0 5000 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0.2 10.2 V 40 0.1 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 12 V 0.2 (CFM) PWM duty cycle 0.3 13.8 V 60 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 6000 Fan speed 0.2 (min-1) PWM duty cycle 100% PWM100% 80 Fan speed 60 Static pressure Static pressure 0.3 (inch H2O) (Pa) 12 VDC DC12 V 80 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.2 0.4 10 0.6 20 Airflow 0.8 30 1.0 (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM (With pulse sensor with PWM control function) DC Dimensions (unit: mm) 300 +50 0 (10) 71.50.3 Lead wire 800.5 AWG28 UL 1007 Rotating direction DC Fan 80 mm sq. 800.5 71.50.3 4-o4.50.3 Mounting hole (4) (4) 150.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 99 DC Fan 80x80x15 mm San Ace 80 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 68 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0812H701 109P0812M701 109P0824H701 109P0824M701 [V] 12 7 to 13.8 24 14 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.2 0.09 0.1 0.05 2.4 1.08 2.4 1.2 3100 2000 3100 2000 0.91 0.57 0.91 0.57 32.1 20.1 32.1 20.1 29.4 12.6 29.4 12.6 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.118 0.051 0.118 0.051 31 21 31 21 [C] [h] -20 to +70 40000/60C 60000/60C 40000/60C 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P0812H701 109P0812M701 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) Static pressure 0.12 13.8 V 30 12 V 0.10 0.08 20 7V 0.06 0.04 10 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 100 0.06 0.05 10 20 30 Airflow 40 (CFM) 0.16 16 12 V 12 0.03 0.02 0 7V 8 40 0.14 13.2 V 0.04 0.01 0.02 0 (inch H2O) (Pa) Static pressure 0.07 0.14 With pulse sensor Operating voltage range (inch H2O) (Pa) 40 Static pressure 0.16 109P0824H701 With pulse sensor 4 0.12 27.6 V 30 24 V 0.10 0.08 20 14 V 0.06 0.04 10 0.02 0 0.2 0 5 0.4 10 15 0.6 20 Airflow 0.8 (m3/min) 25 30 (CFM) 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 10 20 30 Airflow 40 (CFM) 109P0824M701 DC Airflow - Static Pressure Characteristics With pulse sensor DC Fan 80 mm sq. Operating voltage range (inch H2O) (Pa) Static pressure 0.07 0.06 0.05 16 27.6 V 24 V 12 0.04 0.03 0.02 0.01 0 14 V 8 4 0 0.2 0 5 0.4 10 0.6 15 20 Airflow 0.8 (m3/min) 25 30 (CFM) Dimensions (unit: mm) +1 15 0 4-o4.30.3 Mounting hole Lead wire AWG24 UL 1007 +30 300 0 71.50.3 800.5 800.5 71.50.3 (3.5) (3.5) (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 71.50.3 4-o4.5 5 9. 4 o8 78 71.50.3 o8 78 4-o4.5 78 71.50.3 71.50.3 78 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 101 DC Fan 80x80x20 mm San Ace 80 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 80 g Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] PWM duty cycle* [%] Rated current Rated input Rated speed [A] Max. airflow [min-1] [W] [m/min] [CFM] Max. static pressure [Pa] [inchHO] SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 60000/60C 40000/60C (70000/40C) 60000/60C 0.3 3.6 5850 1.72 60.78 110 0.44 45 9GA0812P6M001 0.06 0.72 2900 0.84 29.68 27 0.11 26.5 9GA0824P6G0 01 0.15 3.6 5850 1.72 60.78 110 0.44 45 0.03 0.72 2900 0.84 29.68 27 0.11 26.5 9GA0812P6G001 12 10.2 to 13.8 24 20.4 to 27.6 100 100 9GA0824P6M001 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0812P6G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.4 100 0.3 0.2 0.1 0 80 60 40 20 0 50% 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow 102 (CFM) 0.2 0.1 0 10.2 V 80 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5850 min-1 12 V 0.4 100 0.3 7500 13.8 V 0.5 120 PWM PWM duty cycle 100% (min-1) PWM duty cycle 100% PWM100% 140 Static pressure Static pressure 0.5 120 (inch H2O) (Pa) DC12 V 12 VDC 140 PWM duty - Speed characteristics example Fan speed PWM duty cycle 60 40 5000 2500 20 0 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 40 0.16 30 PWM duty cycle PWM 100% 0.10 0.08 20 0.06 0.04 10 50% 0.02 0 0 0.2 0.4 0.6 0.8 60 40 50% 20 0.4 0.8 9GA0824P6M001 1.2 1.6 0.3 0.2 0.1 0 2.0 (m3/min) (min-1) 7500 27.6 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5850 min-1 24 V 20.4 V 60 40 5000 2500 20 0 0.4 0.8 1.2 1.6 100 (%) 0 2.0 (m3/min) Operating voltage range (inch H2O) (Pa) 24 VDC DC24 V 40 0.16 PWM duty cycle PWM PWM duty cycle PWM 100% 20 50% 0.12 40 (min-1) 3000 30 24 V 20.4 V 20 0.06 0.04 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 2900 min-1 27.6 V 0.10 0.08 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 0.14 Static pressure Static pressure PWM duty - Speed characteristics example Airflow 0.06 10 2000 1000 0.02 0.02 0 PWM duty cycle PWM (CFM) 0 10 20 30 40 50 60 70 (CFM) 0.14 10 100 (%) 0 1.0 (m3/min) With pulse sensor with PWM control function (inch H2O) (Pa) 0.04 0.8 PWM duty cycle 100% PWM100% 80 (CFM) PWM duty cycle 0.10 0.6 Airflow 0.4 100 Airflow 30 0.4 5 10 15 20 25 30 35 0.5 120 Static pressure Static pressure 0 140 80 0 10 20 30 40 50 60 70 0.08 0.2 (inch H2O) (Pa) PWM PWM duty cycle 100% 0.4 100 0 0 Operating voltage range DC24 V 24 VDC 0.5 120 0.12 1000 With pulse sensor with PWM control function 140 0.16 2000 10 Airflow (inch H2O) (Pa) 0 10.2 V 20 (CFM) PWM duty cycle 0.1 0 1.0 (m3/min) 5 10 15 20 25 30 35 9GA0824P6G001 0.2 12 V 0.06 0.04 2900 min-1 13.8 V 30 0.10 0.08 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 0.02 0 0.3 0.12 3000 Fan speed 0.12 40 0.14 Static pressure Static pressure 0.14 (min-1) PWM duty cycle 100% PWM100% Fan speed 0.16 (inch H2O) (Pa) 12 VDC DC12 V PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 0.2 0.4 0 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow (CFM) 0 0 0.2 0 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 103 DC Fan 80 mm sq. 9GA0812P6M001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) 200.5 (4) 71.50.3 800.5 4-o4.50.3 Mounting hole 300 (4) +50 0 (10) Lead wire AWG26 UL 1007 71.50.3 800.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 104 Resin finger guards page: p. 539 DC DC Fan DC Fan 80 mm sq. 80x80x20 mm San Ace 80 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 100 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P0812C601 109P0812H601 109P0812M601 109P0824H601 109P0824M601 109P0848C601 109P0848H601 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 38 to 57.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.29 0.21 0.13 0.12 0.07 0.08 0.05 3.48 2.52 1.56 2.88 1.68 3.84 2.4 3700 2900 2300 2900 2300 3700 2900 1.07 0.84 0.67 0.84 0.67 1.07 0.84 37.8 29.7 23.7 29.7 23.7 37.8 29.7 46 29.4 18.6 29.4 18.6 46 29.4 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] 39 31 25 31 25 39 31 -20 to +60 0.185 0.118 0.075 0.118 0.075 0.185 0.118 [h] 60000/60C -20 to +70 -20 to +70 -20 to +60 40000/60C The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 563. Without sensor Airflow - Static Pressure Characteristics 109P0812C601 109P0812H601 With pulse sensor Operating voltage range Operating voltage range 0.25 60 0.14 0.20 50 0.10 0.05 0 13.8 V 12 V 40 30 10.2 V 20 10 0.12 (inch H2O) (Pa) 0.12 40 13.8 V 30 12 V 10.2 V 0.10 0.08 Static pressure 0.16 20 0.06 0.04 10 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 30 0.10 0.08 13.8 V 20 12 V 0.06 0.04 10.2 V 10 0.02 0.02 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 70 Static pressure Static pressure (inch H2O) (Pa) 0.15 109P0812M601 With pulse sensor 0 0.5 0 10 20 Airflow 1.0 30 (m3/min) 40 (CFM) 0 0 0.5 0 10 20 Airflow 1.0 30 (m3/min) 40 (CFM) 105 Airflow - Static Pressure Characteristics 109P0824H601 109P0824M601 With pulse sensor Operating voltage range Operating voltage range 0.12 27.6 V 30 24 V 20.4 V 0.10 0.08 Static pressure Static pressure 0.14 0.12 20 0.06 0.04 10 0.30 30 0.10 0.08 27.6 V 20 24 V 0.06 0.04 0 0.5 0 10 1.0 20 30 Airflow 109P0848H601 20.4 V 10 0 (m3/min) 40 (CFM) 0 0.5 0 10 20 Airflow 1.0 30 With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 40 57.6 V 30 48 V 20 38 V 10 0 0.5 0 10 1.0 20 30 Airflow 40 1.5 (m3/min) 50 (CFM) Dimensions (unit: mm) 800.5 71.50.3 4-o4.30.3 Mounting hole 0 20 -1 (3.5) (3.5) 71.50.3 800.5 ) (10 +300 30 0 Lead wire AWG24 UL 1007 Rotating direction 106 0.25 0.02 0.02 0 (inch H2O) (Pa) (inch H2O) (Pa) 40 With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.16 109P0848C601 With pulse sensor Airflow direction (m3/min) 40 (CFM) 70 60 0.20 50 0.15 40 0.10 0.05 0 57.6 V 48 V 38 V 30 20 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) 60 (CFM) Outlet side 71.50.3 4-o4.5 5 9. 8 o8 78 71.50.3 o8 78 4-o4.5 78 71.50.3 71.50.3 DC Fan 80 mm sq. Inlet side DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 78 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 107 DC Fan 80x80x25 mm San Ace 80 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Control Brown Mass ...................................................... 110 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GA0812P4J001 12 9GA0812P4G001 10.8 to 13.2 9GA0812P4H001 9GA0824P4J001 24 9GA0824P4G001 21.6 to 26.4 9GA0824P4H001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 25 100 25 100 25 100 25 100 25 100 25 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.6 0.08 0.48 0.06 0.22 0.06 0.28 0.06 0.21 0.04 0.1 0.02 7.2 0.96 5.76 0.72 2.64 0.72 6.72 1.44 5.04 0.96 2.4 0.48 7400 2500 6800 1500 5200 1600 7400 2800 6800 2100 5200 1500 2.07 0.69 1.91 0.42 1.46 0.44 2.07 0.78 1.91 0.58 1.46 0.42 73.0 24.3 67.4 14.8 51.5 15.5 73.0 27.5 67.4 20.4 51.5 14.8 177.6 20.2 150 7.2 87.7 8.3 177.6 25.4 150 14.3 87.7 7.2 [inchHO] 0.7 0.08 0.6 0.02 0.35 0.03 0.7 0.1 0.6 0.05 0.35 0.02 SPL Operating temperature Expected life [dB (A)] [C] [h] 48 21 45 17 37 17 48 23 45 19 37 17 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on pp. 571 to 572. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0812P4J001 With pulse sensor with PWM control function Operating voltage range 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 108 (inch H2O) (Pa) 12 VDC DC12 V PWM PWM duty cycle 100% Static pressure Static pressure (inch H2O) (Pa) 60% 25% 0 0.5 0 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) (min-1) PWM duty cycle 100% PWM100% 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 PWM duty - Speed characteristics example 8000 7000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7400 min-1 6000 13.2 V Fan speed PWM duty cycle 12 V 10.8 V 5000 4000 3000 2000 1000 0 0.5 0 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 100% Static pressure 0.4 100 0.1 0 60% 40 20 25% 0 0.5 0 0.1 1.0 20 1.5 40 2.0 60 Static pressure Static pressure PWM PWM duty cycle 100% 60% 25% 0.5 1.0 9GA0824P4J001 1.5 2.0 (m3/min) Static pressure Static pressure 60% 25% 0.5 1.0 40 1.5 2.0 60 Airflow (CFM) 0 20 PWM PWM duty cycle 100% Static pressure Static pressure Airflow 60% 0 20 100 (%) PWM duty - Speed characteristics example (min-1) 7000 12 V 10.8 V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5200 min-1 5000 4000 3000 2000 1000 0.5 1.0 1.5 2.0 (m3/min) 0 100 (%) PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7400 min-1 7000 6000 26.4 V 24 V 21.6 V 5000 4000 3000 2000 1000 0 0.5 0 20 1.0 1.5 40 2.0 60 2.5 (m3/min) 80 Airflow 0 100 (%) PWM PWM duty cycle (CFM) 0.3 0.2 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 0.7 180 160 0.6 140 0.5 120 0.4 100 0.1 25% 0.5 0 PWM duty cycle PWM (CFM) 13.2 V (inch H2O) (Pa) 24 VDC DC24 V 0 2000 With pulse sensor with PWM control function 80 40 2.5 (m3/min) 80 Operating voltage range 60 3000 6000 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 2.5 (m3/min) 80 0.4 100 0.1 2.0 60 PWM duty cycle 100% PWM100% (inch H2O) (Pa) PWM PWM duty cycle 100% (inch H2O) (Pa) 0.2 1.5 40 0 10 20 30 40 50 60 70 24 VDC DC24 V 9GA0824P4G001 0.3 1.0 20 Airflow PWM duty cycle 0.7 180 160 0.6 140 0.5 120 0.5 Operating voltage range 20 4000 With pulse sensor with PWM control function (inch H2O) (Pa) 0 5000 1000 20 0.40 100 0.35 90 0.30 80 70 0.25 60 0.20 50 0.15 40 0.10 30 20 0.05 10 0 0 (CFM) PWM duty cycle 0 40 (inch H2O) (Pa) 12 VDC DC12 V Airflow 0 10.8 V Operating voltage range 0 10 20 30 40 50 60 70 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 12 V 60 0 6800 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0 13.2 V 80 0 (CFM) PWM duty cycle 0 0 2.5 (m3/min) 80 Airflow 9GA0812P4H001 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0.2 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 0.2 60 0.3 7000 Fan speed 0.3 80 (min-1) PWM duty cycle 100% PWM100% 0.7 180 160 0.6 140 0.5 120 0.4 100 7000 26.4 V 24 V 80 21.6 V 60 40 0 6800 min-1 5000 4000 3000 2000 1000 20 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed Static pressure (inch H2O) (Pa) 12 VDC DC12 V 0.7 180 160 0.6 140 0.5 120 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM PWM duty cycle 109 DC Fan 80 mm sq. 9GA0812P4G001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0824P4H001 With pulse sensor with PWM control function Operating voltage range 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0 0 (inch H2O) (Pa) 24 VDC DC24 V PWM duty cycle PWM 100% Static pressure Static pressure (inch H2O) (Pa) 60% 25% 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow Dimensions (unit: mm) 0.40 100 0.35 90 0.30 80 70 0.25 60 0.20 50 0.15 40 0.10 30 20 0.05 10 0 0 PWM duty - Speed characteristics example 7000 26.4 V 24 V 21.6 V 5000 4000 3000 2000 0.5 1.0 1.5 2.0 (m3/min) 0 4-o4.50.3 +50 300 0 71.50.3 800.5 Mounting hole (10) Lead wire AWG26 UL 1007 (4) (4) 25.20.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 0 78.5 71.50.3 o9 78.5 110 100 (%) PWMPWM duty cycle (CFM) (With ribs) 800.5 5200 min-1 1000 Airflow 71.50.3 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 0 10 20 30 40 50 60 70 (CFM) (min-1) PWM duty cycle 100% PWM100% Fan speed PWM duty cycle page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 DC Fan 80 mm sq. Finger guards DC Options Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 111 DC Fan 80x80x25 mm San Ace 80 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 125 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GV0812P4K03 12 10.2 to 13.8 9GV0824P4K01 24 20.4 to 27.6 9GV0848P4K03 48 43 to 53 9GV0812P4J03 PWM duty cycle* [%] 100 0 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.87 0.1 0.47 0.07 0.44 0.06 0.22 0.04 10.4 1.2 5.6 0.8 10.56 1.44 10.56 1.92 5600 1400 4500 1200 5600 1400 5600 1500 2.12 0.5 1.72 0.45 2.12 0.53 2.12 0.57 74.8 18.7 60.7 16.2 74.8 18.7 74.8 20.1 173.0 10.3 110.0 7.5 173.0 10.8 173.0 12.4 [inchHO] 0.69 0.04 0.44 0.03 0.69 0.04 0.69 0.05 SPL Operating temperature Expected life [dB (A)] [C] [h] 52 18 46 14 52 18 52 19 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 574. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (inch H2O)(Pa) (Pa) 12 VDCV V DC12 DC12 Static pressure 0.80.8 200 200 0.60.6 150 150 PWM PWM duty cycle PWM 100% 100% 0.40.4 100 100 0.20.2 5050 50% 50% 0% 0% 00 00 3 3 (m(m /min) /min) 0.50.5 1.01.0 1.51.5 2.02.0 2.52.5 0 0 2020 4040 6060 8080 (CFM) (CFM) Airflow 112 (inch H2O) (Pa) (inch H2O) (Pa) 1.01.0250 250 0.80.8200 200 0.60.6150 150 0.40.4100 100 PWM duty - Speed characteristics example 00 00 6000 1212V V 10.2 10.2V V 3 3 (m(m /min) /min) 0.50.5 1.01.0 1.51.5 2.02.0 2.52.5 Airflow 5600 min-1 4000 3000 2000 1000 2020 4040 6060 8080 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 13.8 13.8V V 0.20.2 5050 00 (min-1) PWM100% PWM100% PWM duty cycle 100% Fan speed PWM duty cycle Static pressure 9GV0812P4K03 (CFM) (CFM) 0 1400 min-1 100 (%) PWM PWM duty cycle With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 00 6060 4040 2020 00 50% 50% 0% 0% 2020 4040 Airflow 9GV0824P4K01 6060 100 0.2 50 10.2 10.2V V 6060 4040 00 00 3 3 /min) (m(m /min) 0.50.5 1.01.0 1.51.5 2.02.0 00 2020 4040 Airflow 6060 (inch H2O) (Pa) 24 VDC DC24 V 0.8 PWM duty cycle PWM 100% 50% 0 20 9GV0848P4K03 1.0 40 1.5 2.0 0.6 60 80 Airflow 0.2 50 6000 27.6 V 5000 24 V 4000 150 100 (min-1) 20.4 V Static pressure 0.4 100 0.2 0.5 1.0 20 1.5 40 2.0 60 Airflow (inch H2O) (Pa) 48 VDC DC48 V 0.8 PWM PWM duty cycle 100% 50% 50 0 0.5 0 20 1400 min-1 100 (%) PWM duty cycle PWM (CFM) PWM duty cycle 100% PWM100% 200 0.6 150 0.4 100 PWM duty - Speed characteristics example (min-1) 48 V 50 4000 3000 2000 1000 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 0 0.5 0 20 1.0 40 1.5 60 Airflow 5600 min-1 5000 53 V 43 V 0.2 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6000 0% 0 2000 0 2.5 (m3/min) 80 5600 min-1 3000 1000 Operating voltage range 200 150 0 0 (CFM) Voltage: 24 VDC DC24 V PWM frequency: kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.6 100 (%) PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 200 0.4 0 2.5 (m3/min) PWM duty cycle 0.8 2000 0 Fan speed 0.5 Static pressure 0 3000 PWM PWM duty cycle (CFM) (CFM) 0% 0 4500 min-1 4000 -1 1000 1200 min 0.10.1 2020 Static pressure Static pressure 0.4 8080 Operating voltage range 200 150 1212V V With pulse sensor with PWM control function (inch H2O) (Pa) 0.6 0.20.2 (CFM) (CFM) PWM duty cycle 0.8 0.30.3 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 13.8 13.8V V 0.40.4100 100 3 3 /min) (m(m 0.50.5 1.01.0 1.51.5 2.02.0 /min) 00 6000 Fan speed 0.10.1 8080 Static pressure Static pressure 0.20.2 PWM PWM PWM duty cycle 100% 100% (min-1) PWM duty cycle 100% PWM100% PWM100% 140 140 0.50.5120 120 0.40.4 100 100 0.30.3 (inch H2O) (Pa) (inch H2O) (Pa) 12 VDC DC12 V V DC12 120 120 PWM duty - Speed characteristics example Fan speed PWM duty cycle 2.0 2.5 (m3/min) 80 (CFM) 0 1500 min-1 100 (%) PWM PWM duty cycle 113 DC Fan 80 mm sq. 9GV0812P4J03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) (With ribs) 4-o4.50.3 Mounting hole +30 300 0 71.50.3 800.5 Lead wire AWG26 UL 1007 (10) (4) 71.50.3 (4) 25.20.5 800.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 114 Resin finger guards page: p. 539 DC DC Fan San Ace 80 9R type DC Fan 80 mm sq. 80x80x25 mm Model 109R0812E401 is not certified. General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 110 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109R0805F401 109R0805M401 109R0812G401 109R0812E401 109R0812S401 109R0812H401 109R0812F401 109R0812M401 109R0812L401 109R0824G401 109R0824S401 109R0824H401 109R0824F401 109R0824M401 109R0824L401 109R0848K401 109R0848S401 [V] 5 4.5 to 5.5 10.8 to 13.2 12 6 to 13.8 7 to 13.8 20.4 to 26.4 24 12 to 27.6 14 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.25 0.17 0.37 0.24 0.18 0.13 0.11 0.09 0.06 0.2 0.1 0.07 0.06 0.05 0.04 0.1 0.06 1.25 0.85 4.44 2.88 2.16 1.56 1.32 1.08 0.72 4.8 2.4 1.68 1.44 1.2 0.96 4.8 2.88 2600 2350 4500 3700 3400 2900 2600 2350 1850 4500 3400 2900 2600 2350 1850 4600 3400 0.92 0.83 1.5 1.31 1.2 1.03 0.92 0.83 0.65 1.5 1.2 1.03 0.92 0.83 0.65 1.56 1.2 32.5 29.3 53.0 46.3 42.4 36.4 32.5 29.3 23.0 53.0 42.4 36.4 32.5 29.3 23.0 55.1 42.4 28.4 22.5 80.4 57.8 48.0 35.3 28.4 22.5 14.7 80.4 48.0 35.3 28.4 22.5 14.7 88.4 48.0 [inchHO] SPL [dB (A)] 0.114 0.09 0.323 0.232 0.193 0.142 0.114 0.09 0.059 0.323 0.193 0.142 0.114 0.09 0.059 0.355 0.193 26 23 40 35 34 29 26 23 20 40 34 29 26 23 20 41 34 Operating temperature Expected life [C] [h] -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 -20 to +70 40000/60C 60000/60C The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 564 to 565. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109R0805F401 109R0805M401 With pulse sensor Operating voltage range Operating voltage range 0.125 0.050 0.025 0 0.40 0.14 40 5.5 V 5V 30 4.5 V 0.100 0.075 (inch H2O) (Pa) 40 20 10 0.12 0.35 30 5.5 V 5V 4.5 V 0.10 0.08 Static pressure 0.150 0.16 Static pressure Static pressure 0.175 50 20 0.06 0.04 10 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 0.30 0.25 0.20 0.15 0.10 0.05 0.02 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.200 109R0812G401 With pulse sensor 0 0.4 0 10 0.8 20 30 Airflow 1.2 (m3/min) 40 (CFM) 0 100 90 80 70 60 50 40 30 20 10 0 13.2 V 12 V 10.8 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 0 (m3/min) 10 20 30 40 50 60 70 (CFM) Airflow 115 Airflow - Static Pressure Characteristics 109R0812E401 109R0812S401 With pulse sensor Operating voltage range 109R0812H401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 13.8 V 60 0.20 0.15 0.10 0.05 0 12 V 40 20 6V 0 0.5 1.5 1.0 2.0 (m3/min) 0 10 20 30 40 50 60 70 60 0.20 50 0.15 0.10 20 0.05 10 0 0 0.125 0.16 0.050 0.025 0 40 13.8 V 12 V 30 6V 20 10 0 0.5 10 109R0824G401 20 1.0 30 Airflow 40 50 0.20 0.15 0.10 0.05 0 26.4 V 24 V 20.4 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 (m3/min) 0.025 0 0.04 10 0 0.5 0 20 10 1.0 30 1.5 (m3/min) 40 Airflow 50 (CFM) With pulse sensor Operating voltage range 0.06 10 0 0.4 10 0.8 20 30 Airflow 1.2 (m3/min) 40 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 25 20 13.8 V 12 V 15 7V 10 5 0 0.2 0 (CFM) 0.4 10 5 109R0824H401 With pulse sensor 0.6 15 20 Airflow 0.8 25 (m3/min) 30 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 70 0.25 60 0.20 50 0.15 0.10 0.175 24 V 12 V 30 20 0.05 10 0 0 0.5 10 1.0 0.125 20 30 Airflow 40 50 0.075 0.050 0 30 12 V 20 10 0.12 0.5 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 10 0 0.5 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) With pulse sensor (inch H2O) (Pa) 40 30 27.6 V 24 V 20 12 V 10 0.02 0 12 V 20 Operating voltage range 0.06 0.04 30 109R0824L401 With pulse sensor 0.10 0.08 27.6 V 24 V 0 0.14 27.6 V 24 V 40 (CFM) (inch H2O) (Pa) 40 50 0.100 1.5 (m3/min) Operating voltage range 0.16 0.150 0.025 109R0824M401 With pulse sensor 0.200 27.6 V 40 Airflow 50 0 116 0 6V 20 109R0812L401 6V 0 Static pressure Static pressure 0.050 20 10 20 30 40 50 60 70 (CFM) 0.100 0.075 0.08 30 (CFM) Operating voltage range (inch H2O) (Pa) 0.125 50 13.8 V 12 V 0.10 0.30 100 90 80 70 60 50 40 30 20 10 0 109R0824F401 0.150 0.050 1.5 (m3/min) With pulse sensor 30 109R0824S401 With pulse sensor Operating voltage range 0.175 Airflow 40 13.8 V 12 V (inch H2O) (Pa) 0 0.200 30 40 (inch H2O) (Pa) 0 Static pressure Static pressure 0.25 0.075 40 (CFM) (inch H2O) (Pa) 0.30 0.12 0 1.5 (m3/min) Operating voltage range 0.35 20 50 0.100 0.02 0 0.40 0.125 0.14 0.100 0.075 10 1.0 (inch H2O) (Pa) Static pressure Static pressure 0.150 0.5 0 50 0.150 0.025 Operating voltage range (inch H2O) (Pa) 0.175 6V 109R0812M401 Operating voltage range 0.200 12 V 30 (CFM) With pulse sensor 0.175 40 Airflow 109R0812F401 0.200 13.8 V Static pressure 0.25 80 0.25 Static pressure 0.30 (inch H2O) (Pa) 70 Static pressure Static pressure 0.35 100 Static pressure 0.40 Static pressure 0.30 (inch H2O) (Pa) With pulse sensor 0 0.4 0 10 0.8 20 30 Airflow 1.2 (m3/min) 40 (CFM) 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 25 20 27.6 V 24 V 15 14 V 10 5 0 0.2 0 5 0.4 10 15 0.6 20 Airflow 0.8 25 (m3/min) 30 (CFM) 109R0848S401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) Static pressure 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 0.30 110 100 90 80 70 60 50 40 30 20 10 0 55.2 V 48 V 40.8 V 0.5 1.0 1.5 Static pressure 0.45 With pulse sensor DC Fan 80 mm sq. 109R0848K401 DC Airflow - Static Pressure Characteristics 60 0.20 50 0.15 0.10 Airflow Dimensions (unit: mm) 55.2 V 48 V 40 40.8 V 30 20 0.05 10 0 0 2.0 (m3/min) 0 10 20 30 40 50 60 70 70 0.25 0.5 0 (CFM) 10 20 Airflow 40 1.5 (m3/min) 50 (CFM) (With ribs) 800.5 71.50.3 1.0 30 4-o4.30.3 Mounting hole 250.5 (3) (3) +30 300 0 71.50.3 800.5 Lead wire AWG24 UL 1007 (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 117 DC Fan 80x80x25 mm San Cooler 80 9A type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 90 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9A0812G401 9 A 0 8 1 2 S 4 01 9A0812H401 9 A 0 8 1 2 F 4 01 9A0812M401 9 A 0 8 1 2 L 4 01 9A0824G401 9 A 0 8 2 4 S 4 01 9A0824H401 9 A 0 8 2 4 F 4 01 9A0824M401 9 A 0 8 2 4 L 4 01 12 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 6 to 13.2 0.38 0.18 0.13 0.11 0.09 0.06 0.21 0.1 0.07 0.06 0.05 0.04 4.56 2.16 1.56 1.32 1.08 0.72 5.04 2.4 1.68 1.44 1.2 0.96 4500 3400 2900 2600 2350 1850 4500 3400 2900 2600 2350 1850 1.5 1.2 1.03 0.92 0.83 0.65 1.5 1.2 1.03 0.92 0.83 0.65 53.0 42.4 36.4 32.5 29.3 23.0 53.0 42.4 36.4 32.5 29.3 23.0 80.3 48 35.3 28.4 22.5 14.7 80.3 48 35.3 28.4 22.5 14.7 6 to 13.8 7 to 13.8 12 to 26.4 24 Rated speed [V] 12 to 27.6 14 to 27.6 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 40 34 29 26 23 20 40 34 29 26 23 20 -20 to +60 30000/60C -20 to +70 40000/60C -20 to +60 30000/60C -20 to +70 40000/60C 0.323 0.193 0.142 0.114 0.09 0.059 0.323 0.193 0.142 0.114 0.09 0.059 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on pp. 565 to 566. PWM control Airflow - Static Pressure Characteristics 9A0812G401 9A0812S401 With pulse sensor Operating voltage range Operating voltage range 0.25 0.20 0.15 0.10 0.05 0 13.2 V 12 V 6V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 0 118 (m3/min) 10 20 30 40 50 60 70 (CFM) Airflow 0.25 60 0.20 50 0.15 0.10 (inch H2O) (Pa) 70 0.20 Static pressure 0.30 Static pressure Static pressure 0.35 0.30 100 90 80 70 60 50 40 30 20 10 0 13.8 V 40 12 V 30 6V 20 0.05 10 0 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.40 9A0812H401 With pulse sensor 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0.15 50 40 13.8 V 30 12 V 6V 0.10 20 0.05 0 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 9A0812M401 With pulse sensor Operating voltage range Operating voltage range 0.12 30 13.8 V 0.10 12 V 20 6V 0.06 0.04 10 0 0.5 0 9A0824G401 10 1.0 20 30 Airflow 40 50 0.25 0.20 0.15 0.10 0.05 0 26.4 V 24 V 12 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 (m3/min) 0.25 60 0.20 50 30 Airflow 0.15 0.10 0 0 24 V 12 V 0.5 10 20 1.0 30 27.6 V 30 Airflow 40 50 0.10 24 V 20 12 V 0.06 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 30 Airflow (m3/min) 40 (CFM) With pulse sensor 40 27.6 V 30 24 V 12 V 0.10 20 0.05 10 0 0.5 0 9A0824L401 10 20 1.0 30 Airflow 1.5 (m3/min) 40 50 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.10 27.6 V 20 24 V 12 V 10 0.02 0.02 0.15 0 30 0.06 0.04 1.0 20 50 (CFM) With pulse sensor 0.10 0.08 0.5 10 0 1.5 (m3/min) (inch H2O) (Pa) 0.12 0 Operating voltage range Operating voltage range 40 7V 0.02 9A0824H401 27.6 V 9A0824M401 With pulse sensor 13.8 V 12 V 10 40 (CFM) 20 10 0.04 0.20 30 0.05 20 0.06 0 (m3/min) With pulse sensor 40 Airflow Static pressure Static pressure 20 0.08 (inch H2O) (Pa) 0 0.14 0 10 1.0 70 10 20 30 40 50 60 70 (CFM) (inch H2O) (Pa) 0.04 0.5 Operating voltage range Operating voltage range 0.08 0 9A0824S401 With pulse sensor 0.30 100 90 80 70 60 50 40 30 20 10 0 9A0824F401 0.12 10 (inch H2O) (Pa) 0 0.16 0.04 0 Static pressure Static pressure 0.30 12 V 6V (CFM) (inch H2O) (Pa) 0.35 13.8 V 20 0.06 0 1.5 (m3/min) Operating voltage range 0.40 0.08 0.02 0.02 0 0.10 Static pressure 0.08 0.10 Static pressure 0.12 Static pressure Static pressure 0.14 (inch H2O) (Pa) 30 Static pressure 40 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.16 9A0812L401 With pulse sensor DC Fan 80 mm sq. 9A0812F401 DC Airflow - Static Pressure Characteristics 0 0.5 0 10 20 Airflow 1.0 30 (m3/min) 40 (CFM) 0.08 20 0.06 0.04 27.6 V 24 V 10 14 V 0.02 0 0 0.5 0 10 20 Airflow 1.0 30 (m3/min) 40 (CFM) 119 Dimensions (unit: mm) (With ribs) 800.5 4-o4.30.3 Mounting hole 71.50.3 250.5 (4) (4) +50 300 0 71.50.3 800.5 Lead wire AWG24 UL 1007 (10) Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 120 Resin finger guards page: p. 539 DC DC Fan San Ace 80 9S type Silent Fan DC Fan 80 mm sq. 80x80x25 mm Model 9S0812H401 is not TUV certified. General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 75 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] [V] 5.0 to 13.2 9S0812H401 9S0812F401 9S0812M401 9S0812L401 9S0824M401 9S0824L401 12 5.0 to 13.8 6.0 to 13.8 24 10 to 26.4 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.23 0.11 0.08 0.05 0.06 0.04 2.76 1.32 0.96 0.6 1.44 0.96 3400 2800 2500 2000 2500 2000 1.12 0.93 0.83 0.66 0.83 0.66 39.5 32.8 29.3 23.3 29.3 23.3 52.15 35.5 27.5 18.1 27.5 18.1 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 31 24 22 16 22 16 -10 to +70 40000/60C 0.2 0.143 0.11 0.073 0.11 0.073 The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 577. Without sensor PWM control Airflow - Static Pressure Characteristics 9S0812H401 9S0812F401 With pulse sensor Operating voltage range Operating voltage range (inch H O) (Pa) 0.20 50 0.15 0.10 Static pressure Static pressure 70 60 13.2 V 40 12 V 30 20 0.05 10 0 0 (inch H2O) (Pa) 5V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 10 20 30 Airflow 40 50 (CFM) 0.15 0.20 50 40 30 0.10 13.8 V 12 V 20 0.05 0 Static pressure 0.20 5V 10 0 With pulse sensor Operating voltage range 2 (inch H2O) (Pa) 0.25 9S0812M401 With pulse sensor 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 5 10 15 20 25 30 35 40 Airflow (CFM) 0.15 0.10 50 40 13.8 V 30 12 V 20 0.05 0 10 5V 0 0.2 0 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 (CFM) Airflow 121 Airflow - Static Pressure Characteristics 9S0812L401 9S0824M401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 40 0.15 13.8 V 30 0.10 12 V 20 0.05 0 (inch H2O) (Pa) 6V 10 0 0.2 0 0.4 0.6 0.8 0.10 0.05 5 10 15 20 25 30 35 (CFM) 26.4 V 30 24 V 10 0.15 0 0.2 0.4 0.6 0.8 50 40 26.4 V 30 0.10 24 V 20 0.05 10 V 0 Airflow Dimensions (unit: mm) 40 20 0 1.0 (m3/min) 0.20 50 Static pressure 0.15 50 0.20 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure Static pressure 0.20 9S0824L401 With pulse sensor 1.0 (m3/min) 5 10 15 20 25 30 35 (CFM) Airflow 0 10 V 10 0 0.2 0 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 (CFM) Airflow (With ribs) 250.5 4-o4.30.3 Mounting hole (4) (4) 800.5 71.50.3 Lead wire AWG24 UL 1007 +50 300 0 (10) 71.50.3 800.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 78.5 71.50.3 o9 0 71.50.3 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 122 Resin finger guards page: p. 539 DC DC Fan DC Fan 80 mm sq. 80x80x32 mm San Ace 80 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 130 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range [V] [V] 9GA0812P2S001 10.2 to 13.8 9GA0812P2H001 12 10.2 to 12.6 9GA0812P2M001 9GA0824P2S001 24 20.4 to 27.6 9GA0848P2S001 48 40.8 to 55.2 PWM duty cycle* [%] 100 0 100 0 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.83 0.08 0.59 0.05 0.35 0.04 0.42 0.05 0.22 0.04 9.96 0.96 7.08 0.6 4.2 0.48 10.1 1.2 10.56 1.92 9700 2800 8700 2600 6700 1400 9700 2800 9700 2800 2.45 0.71 2.2 0.66 1.69 0.35 2.45 0.71 2.45 0.71 86.5 25.1 77.7 23.3 59.6 12.3 86.5 25.1 86.5 25.1 360 30 294 26 171 7.5 360 30 360 30 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 1.45 0.12 1.18 0.105 0.68 0.03 1.45 0.12 1.45 0.12 57 24 54 21 47 10 57 24 57 24 -20 to +70 -20 to +55 40000/60C -20 to +70 -10 to +70 * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 571 to 572. Without sensor Pulse sensor The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. 9GA0812A2001 9GA0812B2001 9GA0812L2001 9GA0824A2001 9GA0824B2001 9GA0824L2001 Rated voltage Operating voltage range Rated current Rated input 12 24 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 6 to 13.2 6 to 13.8 7 to 13.8 12 to 26.4 12 to 27.6 14 to 27.6 0.31 0.13 0.08 0.15 0.08 0.05 3.72 1.56 0.96 3.6 1.92 1.2 6000 4000 2600 6000 4000 2600 1.51 1.01 0.66 1.51 1.01 0.66 53.4 35.7 23.3 53.4 35.7 23.3 13.7 61.2 26 13.7 61.2 26 [V] [inchHO] 0.055 0.25 0.1 0.055 0.25 0.1 SPL Operating temperature Expected life [dB (A)] [C] [h] 44 33 21 44 33 21 -20 to +70 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor 123 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0812P2S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) DC12 V 12 VDC 500 400 PWM duty cycle PWM 100% 300 200 50% 0% 0 20 2 40 60 Airflow 9GA0812P2H001 3 (m3/min) 80 100 Static pressure Static pressure 400 PWM PWM duty cycle 100% 200 50% 0% 0 1 40 20 2 60 Airflow 9GA0812P2M001 10.2 V 0 1 20 2 40 60 Airflow 3 (m3/min) 80 100 3 (m3/min) 80 100 (CFM) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 500 0.4 100 50% 50 (min-1) 13.8 V 300 12 V 200 10.2 V 100 0 20 1 40 2 3 (m3/min) 80 100 (CFM) 60 Airflow 0 1 0.8 200 0.6 150 0.4 100 0.2 50 2 0 (m3/min) Airflow 9GA0824P2S001 (min-1) 12.6 V 12 V 0 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6700 min-1 1400 min-1 0 1 2 (m3/min) 0 10 20 30 40 50 60 70 (CFM) 100 (%) PWM duty cycle PWM Airflow (inch H2O) (Pa) 500 400 PWM PWM duty cycle 100% 300 200 50% 0% 1 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 500 400 27.6 V Fan speed 24 VDC DC24 V Static pressure Static pressure 100 (%) 0 PWM duty cycle 100% PWM100% Operating voltage range (inch H2O) (Pa) 124 2600 min-1 With pulse sensor with PWM control function PWM duty cycle 20 8700 min-1 PWM duty - Speed characteristics example 10.2 V 0 10 20 30 40 50 60 70 (CFM) 0 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 PWM duty cycle PWM 0% 0 100 (%) PWM duty - Speed characteristics example 400 (inch H2O) (Pa) PWM PWM duty cycle 100% 100 2800 min-1 0 PWM duty cycle 100% PWM100% 0 12 VDC DC12 V 0.6 150 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 9700 min-1 PWM duty cycle PWM (CFM) Operating voltage range 0.8 200 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) Static pressure 100 (inch H2O) (Pa) PWM duty cycle 0.2 12 V 200 Operating voltage range 500 0 300 0 DC12 V 12 VDC 100 13.8 V 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 With pulse sensor with PWM control function (inch H2O) (Pa) 300 400 (CFM) PWM duty cycle 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 (min-1) PWM duty cycle 100% PWM100% 500 Fan speed 0 1 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Fan speed 100 Static pressure 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 300 24 V 200 100 20.4 V 0 0 1 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 9700 min-1 2800 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 48 VDC DC48 V 500 400 PWM PWM duty cycle 100% 300 200 50% 0% 0 0 1 20 2 40 60 Airflow 9GA0812A2001 3 (m3/min) 80 100 Static pressure Static pressure 0.35 0.6 150 13.2 V 12 V 0.4 100 50 6V 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 9GA0824A2001 (m3/min) 60 0.15 0.10 0 80 Airflow 15 0 0 0.35 26.4 V 24 V 12 V 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 Airflow (m3/min) (CFM) 75 0.25 60 0.20 0.15 0.10 0.16 13.8 V 12 V 6V 0 0 0 With pulse sensor 40 0.12 13.8 V 30 0.10 0.08 12 V 20 0.06 0.04 10 7V 0.02 0.5 10 1.0 20 30 Airflow 1.5 40 50 0 (m3/min) 0 0.25 0 (CFM) 10 0.5 0.75 20 Airflow 9GA0824L2001 With pulse sensor 1.0 30 (m3/min) (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.16 40 0.14 27.6 V 24 V 30 15 100 (%) 0.14 45 0.05 0 Operating voltage range 90 0.30 2800 min-1 9GA0812L2001 30 0.05 9700 min-1 PWM duty cycle PWM 100 (CFM) With pulse sensor 45 0 Static pressure Static pressure 3 (m3/min) 60 (inch H2O) (Pa) 0.4 100 0 2 40 Operating voltage range 0.8 200 6000 5000 4000 3000 2000 1000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 (inch H2O) (Pa) 9GA0824B2001 With pulse sensor (inch H2O) (Pa) 50 20 90 0.25 (CFM) Operating voltage range 0.2 1 0 75 0.20 10000 9000 8000 7000 100 0.30 Airflow 0.6 150 200 (inch H2O) (Pa) 0.8 200 0 40.8 V Operating voltage range (inch H2O) (Pa) 0 48 V 300 9GA0812B2001 With pulse sensor Operating voltage range 0.2 55.2 V 400 0 (CFM) (min-1) PWM duty cycle 100% PWM100% 500 Static pressure 100 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Static pressure 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 12 V 0.12 27.6 V 30 0.10 0.08 24 V 20 0.06 0.04 10 14 V 0.02 0.5 10 20 1.0 30 Airflow 1.5 40 50 (m3/min) (CFM) 0 0 0 0.25 10 0.5 20 0.75 Airflow 30 1.0 (m3/min) (CFM) 125 DC Fan 80 mm sq. 9GA0848P2S001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) (With ribs) 4-o4.50.3 Mounting hole Lead wire 800.5 71.50.3 AWG26 UL 1430 +50 300 0 (10) (4) 71.50.3 (4) 320.5 800.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 126 Resin finger guards page: p. 539 DC DC Fan DC Fan 80 mm sq. 80x80x38 mm San Ace 80 9HVA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 220 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] 12 9HVA0812P1G001 [V] 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 [A] [W] 3.5 0.2 42 2.4 Max. airflow Max. static pressure [min-1] [m/min] [CFM] [Pa] 16100 4200 3.75 0.96 132 33.9 1350 105 [inchHO] 5.4 0.42 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 73 44 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HVA0812P1G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1200 4 1000 3 2 1400 PWM duty cycle PWM 100% Static pressure Static pressure 5 (inch H2O) (Pa) 12 VDC DC12 V 1400 800 600 60% 400 1 200 0 0 1200 4 1000 3 2 1 20% 1 5 2 3 4 (m /min) 3 0 20 40 60 80 100 120 140 (CFM) Airflow 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 18000 13.2 V 12 V 16000 800 600 400 16100 min-1 12000 10000 8000 6000 4000 200 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 10.8 V Fan speed PWM duty cycle 2000 1 2 3 4 (m /min) 3 0 20 40 60 80 100 120 140 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 127 Dimensions (unit: mm) (With ribs) 4-o4.50.3 Lead wire AWG22 UL 3266 71.50.3 800.5 Mounting hole 300 +50 0 (10) (4) (4) 380.5 71.50.3 800.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 128 Resin finger guards page: p. 539 DC DC Fan DC Fan 80 mm sq. 80x80x38 mm San Ace 80 9HV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 230 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9HV0812P1G601 12 10.8 to 13.2 9HV0824P1G003** 24 21.6 to 26.4 9HV0848P1G001 48 36 to 57 * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.4 0.25 1.7 0.85 0.13 40.8 3 40.8 40.8 6.24 14900 4400 14900 14900 4400 3.7 1.06 3.7 3.7 1.06 130.7 37.5 130.7 130.7 37.5 1000 87.2 1000 1000 87.2 [inchHO] 4.0 0.35 4.0 4.0 0.35 SPL Operating temperature Expected life [dB (A)] [C] [h] 69 40 69 69 40 -20 to +70 40000/60C (70000/40C) -10 to +70 ** Fan does not rotate when PWM duty cycle is 0%. Model no. for a ribless frame model is 9HV0824P1G0011. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 575. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV0812P1G601 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0 0 4.5 PWM PWM duty cycle 100% 50% 0% 1 3.5 3.0 2.5 2.0 1.0 200 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0 16000 13.2 V 14000 10.8 V 600 400 0 0 (min-1) PWM100% PWM duty cycle 100% 12 V 800 1.5 0.5 2 1200 4.0 1000 Static pressure Static pressure 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 (inch H2O) (Pa) 12 VDC DC12 V 1200 PWM duty - Speed characteristics example Fan speed PWM duty cycle Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14900 min-1 12000 10000 8000 6000 4000 4400 min-1 2000 1 2 3 4 (m3/min) 20 40 60 80 100 120 140 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 129 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV0824P1G003 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 24 VDC DC24 V PWM duty cycle PWM 100% 50% 1 2 3 4 (m3/min) 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 0 PWM PWM duty cycle 100% 50% 0% 1 2 3 4 (m3/min) 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 Airflow Dimensions (unit: mm) 10000 8000 6000 2000 1 2 3 4 100 (%) 0 (m3/min) PWM PWM duty cycle PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 16000 57 V 14000 48 V 36 V 1 2 3 4 (m3/min) 71.50.3 (4) 380.5 +50 300 0 (10) Rotating direction 14900 min-1 10000 8000 6000 4400 min-1 2000 (With ribs) 71.50.3 800.5 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 12000 4000 Airflow 4-o4.50.3 Mounting hole 800.5 14900 min-1 4000 0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 120 140 (CFM) 130 21.6 V (inch H2O) (Pa) 48 VDC DC48 V Static pressure Static pressure 0 12000 Operating voltage range (inch H2O) (Pa) 200 24 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 1.0 0.5 14000 Airflow Airflow 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 16000 26.4 V 0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 120 140 (CFM) 9HV0848P1G001 (min-1) PWM duty cycle 100% PWM100% Fan speed 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Lead wire AWG22 UL 1430 Airflow direction (4) 0 100 (%) PWM duty cycle PWM 71.50.3 78.5 71.50.3 o9 78.5 71.50.3 o8 78.5 4-o4.5 0 4-o4.5 3 71.50.3 Outlet side DC Fan 80 mm sq. Inlet side DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 131 DC Fan 80x80x38 mm San Ace 80 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 160 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GA0812P1G61 12 9GA0812P1S61 10.8 to 13.2 9GA0812P1H61 9GA0824P1S61 24 20.4 to 27.6 48 40.8 to 55.2 9GA0824P1H61 9GA0848P1S61 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 0 100 0 100 0 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.2 0.04 0.94 0.1 0.6 0.08 0.47 0.06 0.3 0.05 0.25 0.04 14.4 0.48 11.28 1.2 7.2 0.96 11.28 1.44 7.2 1.2 12 1.92 10500 2000 9550 2900 8250 2500 9550 2900 8250 2500 9550 2900 2.85 0.51 2.6 0.74 2.25 0.64 2.6 0.74 2.25 0.64 2.6 0.74 100.6 18.0 91.8 26.1 79.4 22.6 91.8 26.1 79.4 22.6 91.8 26.1 480 28.7 480 60 380 45 480 60 380 45 480 60 [inchHO] 1.93 0.11 1.93 0.24 1.53 0.18 1.93 0.24 1.53 0.18 1.93 0.24 SPL Operating temperature Expected life [dB (A)] [C] [h] 60 21 59 27 55 24 59 27 55 24 59 27 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 571 to 572. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0812P1G61 With pulse sensor with PWM control function Operating voltage range 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 500 PWM duty cycle PWM 100% 400 300 200 100 50% 0% 0 0 132 12 VDC DC12 V 600 1 20 40 2 60 Airflow (inch H2O) (Pa) Static pressure Static pressure (inch H2O) (Pa) 3 (m3/min) 80 100 (CFM) 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 600 500 (min-1) 13.2 V 400 Fan speed PWM duty cycle 12 V 10.8 V 300 200 100 0 0 1 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 2000 min-1 1000 0 10500 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range 600 500 400 Static pressure PWM duty cycle PWM 100% 300 200 0% 0 1 20 40 2 60 Airflow 9GA0812P1H61 3 (m3/min) 80 100 50% 0% 0 1 20 9GA0824P1S61 40 2 60 Airflow 3 (m3/min) 80 100 Static pressure PWM PWM duty cycle 100% 200 50% 0% 0 20 9GA0824P1H61 1 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) Airflow 3 (m3/min) 24 VDC DC24 V 2.0 500 1.8 1.6 400 PWM PWM duty cycle 100% 1.4 1.2 300 1.0 0.8 200 50% 0.6 0.4 100 0% 0.2 0 0 1 20 0 100 (%) PWM duty cycle PWM 80 100 (CFM) PWM duty - Speed characteristics example 500 (min-1) 10000 13.2 V 400 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8250 min-1 8000 12 V 300 10.8 V 200 6000 4000 -1 2000 2500 min 100 0 1 20 2 40 60 Airflow 3 (m3/min) 100 (%) 0 PWM duty cycle PWM 80 100 (CFM) 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 600 10000 500 9550 min-1 8000 24 V 400 20.4 V 300 200 6000 4000 2000 100 0 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 27.6 V 1 20 2 40 60 Airflow 3 (m3/min) 2900 min-1 0 100 (%) PWM duty cycle PWM 80 100 (CFM) Operating voltage range (inch H2O) (Pa) Static pressure 60 2900 min-1 With pulse sensor with PWM control function PWM duty cycle 0 2 40 PWM duty cycle 100% PWM100% (inch H2O) (Pa) 300 0 1 20 Operating voltage range 600 100 0 0 24 VDC DC24 V 400 4000 With pulse sensor with PWM control function (inch H2O) (Pa) 500 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 (CFM) PWM duty cycle 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 6000 2000 100 Fan speed Static pressure Static pressure PWM PWM duty cycle 100% 200 0 200 (inch H2O) (Pa) 12 VDC DC12 V 500 100 10.8 V 300 With pulse sensor with PWM control function (inch H2O) (Pa) 300 9550 min-1 8000 12 V 400 Operating voltage range 400 10000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 13.2 V 500 0 (CFM) PWM duty cycle 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 600 Fan speed 0 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 (min-1) PWM duty cycle 100% PWM100% 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) (inch H2O) (Pa) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 PWM duty - Speed characteristics example PWM100% 10000 27.6 V 24 V 400 300 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8000 20.4 V 200 8250 min-1 6000 4000 -1 2000 2500 min 100 0 0 (min-1) PWM duty cycle 100% 500 Fan speed 100 50% Static pressure 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 (inch H2O) (Pa) 12 VDC DC12 V Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 0 100 (%) PWM duty cycle PWM 133 DC Fan 80 mm sq. 9GA0812P1S61 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0848P1S61 With pulse sensor with PWM control function Operating voltage range 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 (inch H2O) (Pa) 48 VDC DC48 V 600 500 PWM duty cycle PWM 100% 400 Static pressure Static pressure (inch H2O) (Pa) 300 200 100 50% 0% 0 0 1 20 40 2 60 3 (m3/min) Airflow 80 100 Dimensions (unit: mm) 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 (min-1) PWM duty cycle 100% PWM100% 600 10000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 9550 min-1 55.2 V 500 8000 48 V 400 40.8 V 300 200 6000 4000 2000 100 0 0 (CFM) PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 20 40 2 60 Airflow 3 (m3/min) 2900 min-1 0 (With ribs) 4-o4.50.3 800.5 71.50.3 Mounting hole +50 300 0 (10) Lead wire 71.50.3 AWG26 UL 1430 800.5 Rotating direction (4) (4) 380.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 0 71.50.3 78.5 o9 71.50.3 78.5 134 100 (%) PWM duty cycle PWM 80 100 (CFM) page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 DC Fan 80 mm sq. Finger guards DC Options Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 135 DC Fan 80x80x38 mm San Ace 80 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 220 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GV0812P1G03 10.8 to 13.2 9GV0812P1H03 12 9GV0812P1F03 10.2 to 13.8 9GV0812P1M03 9GV0824P1G03 24 20.4 to 27.6 9GV0848P1G03 48 40.8 to 55.2 PWM duty cycle* [%] 100 0 100 0 100 0 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.8 0.32 3.0 0.2 1.5 0.12 0.75 0.09 1.6 0.3 0.84 0.15 45.6 3.84 36.0 2.4 18 1.44 9 1.08 38.4 7.2 40.32 7.2 10200 3000 9700 2900 8000 2400 6000 1700 10200 4700 10200 4700 3.9 1.15 3.7 1.11 3.05 0.92 2.29 0.65 3.9 1.79 3.9 1.79 138.0 40.6 131.0 39.2 108.0 32.0 81.0 23.0 138.0 63.2 138.0 63.2 490.0 42.4 440.0 39.0 301.0 27.1 169.0 13.6 490.0 104.0 490.0 104.0 [inchHO] 1.97 0.17 1.77 0.16 1.21 0.11 0.68 0.05 1.97 0.41 1.97 0.41 SPL Operating temperature Expected life [dB (A)] [C] [h] 65 34 63 34 58 26 51 19 65 44 65 44 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 574. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch (inch H2O) H2O) (Pa) (Pa) 12 VDC DC12 DC12 V V Static pressure 600 2.42.4 600 500 2.02.0 500 400 1.61.6 400 300 1.21.2 300 PWM PWM PWM duty cycle 100% 100% 50% 50% 200 0.80.8 200 100 0.40.4 100 00 00 0% 0% 3 3 /min) /min) 1 1 2 2 3 3 4 4 5 5(m(m (CFM) 120120 140140 160160 180180(CFM) 0 020 2040 4060 6080 80100100 Airflow 136 (inch (inch H2O) H2O) (Pa) (Pa) 600 2.42.4600 500 2.02.0500 400 1.61.6400 300 1.21.2300 (min-1) PWM100% PWM100% PWM duty cycle 100% 13.2 13.2V V 1212V V 10.8 10.8V V 200 0.80.8200 100 0.40.4100 00 00 PWM duty - Speed characteristics example 3 3 /min) /min) 1 1 2 2 3 3 4 4 5 (m 5 (m (CFM) 120120 140140 160160 180180(CFM) 0 020 2040 4060 6080 80100100 Airflow Fan speed PWM duty cycle Static pressure 9GV0812P1G03 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 11000 10000 9000 8000 7000 6000 5000 4000 3000 3000 min-1 2000 1000 0 10200 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch (inch H2O) H2O) (Pa) (Pa) 500 2.02.0500 PWM PWM PWM duty cycle 400 1.61.6 400 100% 100% 300 1.21.2 300 200 0.80.8 200 100 0.40.4 100 200 0.80.8200 100 0.40.4100 0% 0% 00 00 3 3 /min) /min) 1 1 2 2 3 3 4 4 5 (m 5 (m Airflow 9GV0812P1F03 300 1.21.2 300 PWM PWM PWM duty cycle 100% 100% 200 0.80.8 200 50% 50% 0.40.4 100 100 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 400 1.61.6400 Static pressure Static pressure (inch (inch H2O) H2O) (Pa) (Pa) 12 VDC DC12 DC12 V V 1.61.6 400 400 300 1.21.2300 13.8 13.8V V 1212V V 10.2 10.2V V 200 0.80.8200 0.40.4100 100 0% 0% 11 22 33 00 00 3 3 /min) /min) 4 4(m(m (CFM) (CFM) 0 0 20 20 40 40 60 60 80 80100100120120140140 9GV0812P1M03 (inch (inch H2O) H2O)(Pa) (Pa) 50% 50% 11 22 0.8 200 0.4 100 0 0 4000 3000 2000 1700 min-1 100 (%) 0 PWM duty cycle PWM Airflow Operating voltage range (inch H2O) (Pa) 24 VDC DC24 V PWM PWM duty cycle 100% 50% 0% 1 3 3 /min) /min) 3 (m 3 (m 2 3 4 5 (m3/min) 0 25 50 75 100 125 150 175 (CFM) Airflow 2.4 600 2.0 500 1.6 400 1.2 300 0.8 200 0.4 100 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 27.6 V 24 V Fan speed 300 22 (CFM) 0 0 20 20 40 40 60 60 80 80 100100(CFM) Static pressure Static pressure 1.2 11 6000 min-1 5000 1000 00 00 3 3 /min) /min) 3 (m 3 (m Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 400 7000 0.20.2 5050 0% 0% PWM duty cycle 1.6 (min-1) 0.40.4100100 Airflow 500 PWM duty - Speed characteristics example 13.8 13.8 VV 1212 VV 10.2 10.2 VV 0.60.6150150 (CFM) 0 0 20 20 40 40 60 60 80 80 100100(CFM) 2.0 100 (%) 0 Fan speed 0.60.6 150150 9GV0824P1G03 6000 5000 4000 3000 2000 2400 min-1 1000 6000 0.80.8200200 PWM PWM PWM duty cycle 100% 100% 00 8000 min-1 PWM duty cycle PWM PWM duty cycle 100% PWM100% PWM100% 1.01.0250250 Static pressure 0.80.8 200200 600 3 3 /min) /min) 4 4(m(m Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 Airflow Static pressure 12 VDC DC12 DC12 V V 1.01.0 250250 2.4 33 Operating voltage range (inch (inch H2O) H2O)(Pa) (Pa) 00 22 10000 9000 8000 7000 With pulse sensor with PWM control function PWM duty cycle 0.40.4 100100 11 (CFM) (CFM) 0 0 20 20 40 40 60 60 80 80100100120120140140 Airflow 0.20.2 5050 100 (%) PWM duty cycle PWM Airflow Operating voltage range (Pa) (Pa) (inch (inch H2O) H2O) 00 9700 min-1 With pulse sensor with PWM control function PWM duty cycle 00 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 10000 9000 8000 7000 6000 5000 4000 3000 2900 min-1 2000 1000 0 3 3 /min) /min) 1 1 2 2 3 3 4 4 5 (m 5 (m (CFM) 0 020 2040 4060 6080 80100100 120120 140140 160160 180180(CFM) (CFM) 120120 140140 160160 180180(CFM) 0 020 2040 4060 6080 80100100 Fan speed 00 13.2 13.2V V 1212V V 10.8 10.8V V 400 1.61.6400 300 1.21.2300 50% 50% (min-1) PWM duty cycle 100% PWM100% PWM100% 600 2.42.4600 Static pressure Static pressure 500 2.02.0 500 00 (inch (inch H2O) H2O) (Pa) (Pa) 12 VDC DC12 DC12 V V 600 2.42.4 600 PWM duty - Speed characteristics example Fan speed PWM duty cycle 20.4 V 1 2 3 4 5 (m3/min) 0 25 50 75 100 125 150 175 (CFM) Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 11000 10000 9000 8000 7000 6000 5000 4700 min-1 4000 3000 2000 1000 0 10200 min-1 100 (%) PWM duty cycle PWM Airflow 137 DC Fan 80 mm sq. 9GV0812P1H03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range 2.4 600 2.0 500 1.6 400 1.2 300 0.8 200 0.4 100 0 0 (inch H2O) (Pa) DC48 V 48 VDC PWM PWM duty cycle 100% Static pressure Static pressure (inch H2O) (Pa) 50% 0% 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) (min-1) PWM duty cycle 100% PWM100% 2.4 600 2.0 500 1.6 400 48 V 1.2 300 40.8 V 0.8 200 0.4 100 0 0 55.2 V 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 11000 10000 9000 8000 7000 6000 5000 4700 min-1 4000 3000 2000 1000 0 10200 min-1 100 (%) PWM duty cycle PWM Airflow Airflow Dimensions (unit: mm) PWM duty - Speed characteristics example Fan speed 9GV0848P1G03 (With ribs) 4-o4.30.3 Mounting hole +30 300 0 71.50.3 800.5 Lead wire AWG24 UL 1430 (10) (4) 71.50.3 800.5 380.5 (4) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 138 Resin finger guards page: p. 539 DC DC Fan DC Fan 80 mm sq. 80x80x38 mm San Ace 80 9G type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 170 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. 9G0812K101 9G0812G101 9G0812H101 9G0824G101 9G0824H101 9G0848G101 9G0848H101 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 10.8 to 13.2 1.8 1.1 0.9 0.56 0.42 0.27 0.2 21.6 13.2 10.8 13.4 10.1 13.0 9.6 7800 6300 5700 6300 5700 6300 5700 3.1 2.55 2.28 2.55 2.28 2.55 2.28 107.3 90 80 90 80 90 80 310 211 171 211 171 211 171 [V] 12 7 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] 58 51 49 51 49 51 49 -20 to +60 1.285 0.847 0.687 0.847 0.687 0.847 0.687 -20 to +70 [h] 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 568. Lock sensor PWM control Airflow - Static Pressure Characteristics 9G0812K101 9G0812G101 With pulse sensor Operating voltage range Operating voltage range 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 13.2 V 12 V 10.8 V 0.5 1 1.5 2.0 2.5 3.0 3.5 (m3/min) 0 20 40 60 80 100 120 Airflow (CFM) (inch H2O) (Pa) 0.9 260 240 220 200 180 160 140 120 100 80 60 40 20 0 0.8 Static pressure 1.2 Static pressure Static pressure 350 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 1.4 9G0812H101 With pulse sensor 13.8 V 12 V 7V 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.5 1.0 1.5 2.0 2.5 3.0 0 20 40 60 Airflow (m3/min) 80 100 120 (CFM) 0 220 200 180 160 140 120 100 80 60 40 20 0 13.8 V 12 V 7V 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 20 40 60 Airflow 80 100 (CFM) 139 Airflow - Static Pressure Characteristics 9G0824G101 9G0824H101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 260 240 220 200 180 160 140 120 100 80 60 40 20 0 0.8 27.6 V 24 V 20.4 V 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.5 1.0 1.5 2.0 2.5 3.0 0 20 9G0848H101 40 60 Airflow 0 (m3/min) 80 100 120 (CFM) 220 200 180 160 140 120 100 80 60 40 20 0 27.6 V 24 V 20.4 V 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 20 40 With pulse sensor (inch H2O) (Pa) Static pressure 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 220 200 180 160 140 120 100 80 60 40 20 0 55.2 V 48 V 40.8 V 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 20 40 60 Airflow 80 100 Dimensions (unit: mm) 4-o4.30.3 Mounting hole (CFM) (With ribs) Lead wire AWG24 UL 1007 800.5 71.50.3 +30 300 0 (10) 71.50.3 800.5 Rotating direction 140 60 Airflow Operating voltage range 0.9 Static pressure 0.9 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure Static pressure (inch H2O) (Pa) 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 9G0848G101 With pulse sensor (4) (4) 380.5 Airflow direction 80 100 (CFM) 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 260 240 220 200 180 160 140 120 100 80 60 40 20 0 55.2 V 48 V 40.8 V 0.5 1.0 1.5 2.0 2.5 3.0 0 20 40 60 Airflow (m3/min) 80 100 120 (CFM) DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 DC Fan 80 mm sq. 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 141 DC Fan 92x92x25 mm San Ace 92 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 125 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range [V] [V] 9GA0912P4J03 9GA0912P4G03 12 10.2 to 13.8 9GA0912P4S03 9GA0924P4J03 9GA0924P4G03 24 20.4 to 27.6 9GA0924P4S03 PWM duty cycle* [%] 100 0 100 0 100 0 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.39 0.06 0.28 0.06 0.2 0.06 0.2 0.04 0.15 0.04 0.12 0.04 4.68 0.72 3.36 0.72 2.4 0.72 4.8 0.96 3.6 0.96 2.88 0.96 5000 1500 4400 1500 3800 1500 5000 1500 4400 1500 3800 1500 2.2 0.65 1.93 0.65 1.67 0.65 2.2 0.65 1.93 0.65 1.67 0.65 77.7 23.3 68.2 23.3 59.0 23.3 77.7 23.3 68.2 23.3 59.0 23.3 105 9.4 81 9.4 60.6 9.4 105 9.4 81 9.4 60.6 9.4 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 43 14 39 14 35 14 43 14 39 14 35 14 -20 to +70 60000/60C 0.42 0.04 0.33 0.04 0.24 0.04 0.42 0.04 0.33 0.04 0.24 0.04 * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 572. Lock sensor The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. 9 G A 0 9 1 2 H 4 01 9 G A 0 9 1 2 F 4 01 9GA0912M401 9 G A 0 9 1 2 L 4 01 9GA0912W401 9 G A 0 9 2 4 H 4 01 9 G A 0 9 2 4 F 4 01 9GA0924M401 9 G A 0 9 2 4 L 4 01 9GA0924W401 Rated voltage Operating voltage range Rated current Rated input [V] 12 [V] 10.2 to 13.8 7 to 16 20.4 to 27.6 16 to 27.6 24 14 to 27.6 12 to 28.8 142 Lock sensor Max. airflow Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 0.19 0.14 0.11 0.09 0.19 0.09 0.08 0.05 0.03 0.09 2.28 1.68 1.32 1.08 2.28 2.16 1.92 1.2 0.72 2.16 3300 2800 2400 2000 3300 3300 2800 2400 2000 3300 1.45 1.23 1.05 0.87 1.45 1.45 1.23 1.05 0.87 1.45 51.2 43.5 37.1 30.7 51.2 51.2 43.5 37.1 30.7 51.2 45.6 32.9 24 16.7 45.6 45.6 32.9 24 16.7 45.6 The following sensor and control options are available for selection. Available for all models. Without sensor Rated speed [A] [inchHO] 0.18 0.13 0.096 0.067 0.18 0.18 0.13 0.096 0.067 0.18 SPL Operating temperature Expected life [dB (A)] [C] [h] 31 28 24 21 31 31 28 24 21 31 -20 to +70 60000/60C With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 50% 40 0.5 0 1.0 20 1.5 40 2.0 60 Airflow 9GA0912P4G03 Static pressure 60 40 50% 20 0% 0.5 1.0 20 1.5 40 Static pressure PWM PWM duty cycle 100% 40 50% 0% 0.5 0 1.0 20 1.5 40 Airflow 9GA0924P4J03 Static pressure 0.1 5000 20 0.5 1.0 1.5 20 40 4400 min-1 3000 2000 1000 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 10.2 V 2.0 60 2.5 (m3/min) 80 Airflow 1500 min-1 0 100 (%) PWM duty cycle PWM (CFM) 60 80 (min-1) 5000 13.8 V 60 10.2 V 20 0 0 1.0 20 1.5 40 Airflow 2.0 (m3/min) 60 3800 min-1 3000 2000 1000 0.5 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 12 V 40 0.1 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 0.2 (inch H2O) (Pa) 1500 min-1 100 (%) 0 PWM duty cycle PWM (CFM) PWM PWM duty cycle 100% 60 50% 0% 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0.2 0.1 0 (min-1) 27.6 V 20.4 V 60 40 3000 2000 1500 min-1 1000 20 0 5000 min-1 4000 24 V 80 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 120 0.4 100 0.3 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 140 0.5 80 0 (min-1) 40 (CFM) 24 VDC DC24 V 0.4 100 0 100 (%) PWM duty - Speed characteristics example Operating voltage range 120 0 0 With pulse sensor with PWM control function (inch H2O) (Pa) 20 1500 min-1 PWM duty cycle PWM (CFM) 12 V 0.2 0 2.0 (m3/min) PWM duty cycle 0.1 2.5 (m3/min) 80 Airflow 60 0.3 40 2.0 60 PWM duty cycle 100% PWM100% (inch H2O) (Pa) 60 0.2 1.5 40 13.8 V 0 12 VDC DC12 V 0.2 0.3 1.0 20 Operating voltage range 80 0 2000 With pulse sensor with PWM control function (inch H2O) (Pa) 20 0.5 80 (CFM) PWM duty cycle 0 0.3 0 2.0 (m3/min) 60 Airflow 9GA0912P4S03 0.1 0 0.4 100 PWM PWM duty cycle 100% 0 0.3 20 (inch H2O) (Pa) 12 VDC DC12 V 80 0 3000 1000 0 Static pressure Static pressure 0 40 Operating voltage range 0.4 100 0.1 5000 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0.2 10.2 V 60 (CFM) PWM duty cycle 0.3 0.1 0 2.5 (m3/min) 80 0.2 80 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 12 V Fan speed 0 13.8 V Fan speed 0 0% 20 5000 120 0.4 100 0.3 (min-1) Fan speed 0.1 Static pressure 60 Static pressure Static pressure 0.2 PWM PWM duty cycle 100% 80 PWM duty cycle 100% PWM100% 140 0.5 0.4 100 0.3 (inch H2O) (Pa) 12 VDC DC12 V 120 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM duty cycle PWM 143 DC Fan 92 mm sq. 9GA0912P4J03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0924P4G03 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 100% 60 40 0 0.5 0 1.0 20 1.5 40 60 Airflow 9GA0924P4S03 0.3 60 PWM PWM duty cycle 100% 40 50% 0% 0.5 0 1.0 20 1.5 40 Static pressure Static pressure 13.8 V 12 V 40 10.2 V 20 0 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 (m3/min) 0.1 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 9GA0912L401 0.04 10 0.02 5 0 0 0 144 0.30 12 V 10.2 V 0.25 20.4 V 0.10 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) (CFM) 0 2000 1500 min-1 1000 0 0.5 1.0 20 1.5 40 2.0 (m3/min) 60 Airflow 100 (%) 9GA0912M401 With pulse sensor With pulse sensor Operating voltage range (inch H2O) (Pa) 50 0.16 13.8 V 40 40 0.14 12 V 30 10.2 V 20 10 0.12 30 13.8 V 0.10 0.08 12 V 20 0.06 0.04 10.2 V 10 0.02 0 0.5 10 1.0 20 30 Airflow 1.5 40 50 0 (m3/min) 0 0.5 0 (CFM) 10 9GA0924H401 With pulse sensor 20 1.0 30 Airflow 1.5 40 50 (m3/min) (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 80 0.30 16 V 60 40 20 0 PWM duty cycle PWM (CFM) 12 V 7V 0.05 0.5 3800 min-1 3000 20 0.20 0.15 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 24 V (inch H2O) (Pa) Static pressure Static pressure 15 (min-1) Operating voltage range 13.8 V 0.06 PWM duty - Speed characteristics example 5000 9GA0912W401 With pulse sensor (inch H2O) (Pa) 20 100 (%) 0 PWM duty cycle PWM (CFM) 27.6 V 0 (CFM) Operating voltage range 0.08 Airflow 40 Airflow 25 2.5 (m3/min) 80 (inch H2O) (Pa) 60 0.10 80 0 0.05 0 2.0 60 Operating voltage range 80 0.20 0.10 40 PWM duty cycle 100% PWM100% 9GA0912F401 With pulse sensor (inch H2O) (Pa) 0.15 1.0 1.5 20 60 (CFM) Operating voltage range 0.25 0.5 0.2 0 2.0 (m3/min) 60 Airflow 9GA0912H401 0.30 0 0 Static pressure Static pressure 80 0 1500 min-1 1000 (inch H2O) (Pa) 24 VDC DC24 V 20 2000 20 Operating voltage range 0.2 0 0.1 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.1 40 (CFM) PWM duty cycle 0.3 20.4 V 0.2 0 2.0 (m3/min) 4000 24 V 60 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4400 min-1 27.6 V 80 Fan speed 0 0% 20 5000 Static pressure 0.1 50% 0.3 (min-1) Static pressure 0.2 80 PWM duty cycle 100% PWM100% 0.4 100 Static pressure Static pressure 0.3 (inch H2O) (Pa) 24 VDC DC24 V 0.4 100 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.25 80 60 0.20 0.15 0.10 27.6 V 24 V 40 20.4 V 20 0.05 0 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 Airflow (m3/min) (CFM) 0 0 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 Airflow (m3/min) (CFM) 9GA0924M401 With pulse sensor Operating voltage range Operating voltage range 0.14 27.6 V 40 24 V 30 20 16 V 10 0.12 27.6 V 30 0.10 0.08 24 V 20 14 V 0.06 0.04 10 0.02 0 0 (inch H2O) (Pa) 40 Static pressure 0.16 Static pressure Static pressure 50 0.5 10 9GA0924W401 1.0 20 30 Airflow 1.5 40 0 (m3/min) 50 0 0 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 9GA0924L401 With pulse sensor DC Fan 92 mm sq. 9GA0924F401 DC Airflow - Static Pressure Characteristics 0.5 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) (CFM) 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 27.6 V 24 V 0 14 V 0.5 10 20 1.0 30 Airflow 1.5 40 50 (m3/min) (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.30 0.25 80 28.8 V 60 0.20 0.15 0.10 24 V 40 20 12 V 0.05 0 0 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 (m3/min) (CFM) Airflow Dimensions (unit: mm) (With ribs) 4-o4.50.3 Mounting hole 920.5 82.50.3 Lead wire AWG26 UL 1007 +50 300 0 (10) (4) (4) 25.20.5 82.50.3 920.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 90.5 4-o4.5 4-o4.5 08 o1 90.5 90.5 82.50.3 82.50.3 7 o9 82.50.3 90.5 82.50.3 145 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 146 Resin finger guards page: p. 539 DC DC Fan DC Fan 92 mm sq. 92x92x25 mm San Cooler 92 9A type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 100 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9A0912G401 9 A 0 9 1 2 S 4 01 9A0912H401 9 A 0 9 1 2 F 4 01 9A0912M401 9 A 0 9 1 2 L 4 01 9A0924G401 9 A 0 9 2 4 S 4 01 9A0924H401 9 A 0 9 2 4 F 4 01 9A0924M401 9 A 0 9 2 4 L 4 01 9 A 0 9 4 8 S 4 01 [V] 6 12 7 24 48 12 to 13.8 to 13.8 to 27.6 14 to 27.6 40.5 to 53 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.39 0.27 0.21 0.14 0.12 0.07 0.19 0.15 0.1 0.08 0.05 0.04 0.08 4.68 3.24 2.52 1.68 1.44 0.84 4.56 3.6 2.4 1.92 1.2 0.96 3.84 3900 3550 3150 2650 2250 1750 3900 3550 3150 2650 2250 1750 3550 1.76 1.66 1.45 1.24 1.04 0.8 1.76 1.66 1.45 1.24 1.04 0.8 1.66 62.1 58.6 51.2 43.8 36.7 28.2 62.1 58.6 51.2 43.8 36.7 28.2 58.6 66.5 56.1 44 32.2 22.6 13.4 66.5 56.1 44 32.2 22.6 13.4 56.1 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.267 0.225 0.177 0.129 0.091 0.054 0.267 0.225 0.177 0.129 0.091 0.054 0.225 43 39 33 30 27 23 43 39 33 30 27 23 39 [C] -20 to +60 -20 to +70 -20 to +60 -20 to +70 [h] 30000/60C 40000/60C 30000/60C 40000/60C -20 to +60 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 566. Lock sensor PWM control Airflow - Static Pressure Characteristics 9A0912S401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.40 100 80 0.30 0.25 0.30 80 13.8 V Static pressure Static pressure 0.35 12 V 60 0.20 0.15 0.10 0.05 0 40 20 0 6V 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow 9A0912H401 With pulse sensor (CFM) 60 0.20 50 0.15 40 0.10 (inch H2O) (Pa) 0.25 70 0.25 0.20 13.8 V 12 V 6V 30 20 0.05 10 0 0 With pulse sensor Operating voltage range Static pressure 9A0912G401 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m3/min) (CFM) 0.15 60 13.8 V 50 12 V 40 6V 30 0.10 0.05 0 20 10 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 147 Airflow - Static Pressure Characteristics 9A0912F401 9A0912M401 With pulse sensor Operating voltage range Operating voltage range 13.8 V 12 V 30 6V 20 10 0 0.5 10 1.0 20 30 Airflow 1.5 40 50 80 27.6 V 24 V 60 40 12 V 20 0 0.4 9A0924F401 0.8 1.2 1.6 2.0 (m3/min) 12 V 20 10 0.5 10 1.0 20 30 Airflow 1.5 40 50 (m3/min) 60 (CFM) With pulse sensor (inch H2O) (Pa) Static pressure 80 70 53 V 48 V 40.5 V 30 20 10 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow 148 0.10 0 0 0.12 27.6 V 24 V 12 V 0.5 1.0 1.5 2.0 (CFM) 0 0.2 0.4 10 0.6 0.8 20 30 Airflow 1.0 (m3/min) (CFM) With pulse sensor 60 27.6 V 50 24 V 40 12 V 30 0.10 0.05 20 10 0 0.5 1.5 2.0 (m3/min) Airflow 9A0924L401 With pulse sensor 1.0 0 10 20 30 40 50 60 70 (CFM) (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 40 0.12 27.6 V 30 24 V 12 V 20 10 30 27.6 V 0.10 0.08 24 V 20 0.06 0.04 14 V 10 0.02 0 0 0.15 0 2.5 (m3/min) 0.06 0.04 0 0 0.20 0.10 0.08 7V 10 Operating voltage range 20 10 0.04 0.25 30 0.05 0.06 9A0924H401 0.02 0 0 40 12 V 20 (CFM) Static pressure Static pressure Static pressure 30 9A0948S401 0 50 With pulse sensor 0.14 Operating voltage range 0.05 0.15 0.16 0 0.10 Airflow 40 (inch H2O) (Pa) 24 V 0.15 30 Operating voltage range 40 40 20 Airflow 27.6 V 50 50 0.08 0 1.5 (m3/min) 0 10 20 30 40 50 60 70 80 50 0.20 10 1.0 70 60 13.8 V 0.10 (inch H2O) (Pa) 9A0924M401 With pulse sensor (inch H2O) (Pa) 60 0.5 80 0.20 (CFM) Operating voltage range 0.25 0 0.25 30 0.02 Static pressure 0.30 Airflow 0.30 10 (inch H2O) (Pa) 0 10 20 30 40 50 60 70 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 0.04 Operating voltage range Static pressure Static pressure 0 6V 0.06 9A0924S401 With pulse sensor 0.20 0.05 12 V 20 0 0.40 100 0.10 0.08 60 (CFM) (inch H2O) (Pa) 0.15 13.8 V 30 0.10 0 (m3/min) Operating voltage range 0.25 0.12 0.02 9A0924G401 0.30 0.12 0.14 40 0 0.35 (inch H2O) (Pa) 40 Static pressure 0.16 With pulse sensor Operating voltage range (inch H2O) (Pa) 50 Static pressure Static pressure (inch H2O) (Pa) 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 9A0912L401 With pulse sensor 0.5 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 0 0.2 0 0.4 10 0.6 20 Airflow 0.8 30 1.0 (m3/min) (CFM) DC (With ribs) 250.5 920.5 4-o4.30.3 Mounting hole 82.50.3 (4) (4) DC Fan 92 mm sq. Dimensions (unit: mm) 920.5 82.50.3 Lead wire AWG24 UL 1007 +50 300 0 (10) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side 90.5 Outlet side 02 4- o4.5 o1 90.5 82.50.3 90.5 2 o9 82.50.3 90.5 4- o4.5 82.50.3 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 149 DC Fan 92x92x25 mm San Ace 92 9S type Silent Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 100 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9S0912F401 9S0912M401 9S0912L401 9S0924F401 9S0924M401 9S0924L401 [V] 5.0 to 13.8 12 6.0 to 13.8 24 14 to 26.4 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.14 0.11 0.07 0.09 0.07 0.04 1.68 1.32 0.84 2.16 1.68 0.96 2650 2250 1750 2650 2250 1750 1.26 1.07 0.83 1.26 1.07 0.83 44.5 37.8 29.3 44.5 37.8 29.3 30.0 21.6 13.1 30.0 21.6 13.1 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 27 22 17 27 22 17 -10 to +70 40000/60C 0.12 0.087 0.053 0.12 0.087 0.053 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 577 to 578. Lock sensor PWM control Airflow - Static Pressure Characteristics 9S0912F401 9S0912M401 With pulse sensor Operating voltage range Operating voltage range 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 13.8 V 12 V 5V 0.5 0 150 (inch H2O) (Pa) (inch H2O) (Pa) 0.12 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0.08 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 With pulse sensor Operating voltage range 20 0.07 Static pressure 40 Static pressure Static pressure (inch H2O) (Pa) 0.16 9S0912L401 With pulse sensor 13.8 V 12 V 5V 0.06 15 13.8 V 12 V 10 6V 0.05 0.04 0.03 0.02 5 0.01 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 10 20 30 Airflow 40 50 (CFM) 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 10 20 30 Airflow 40 (CFM) 9S0924M401 With pulse sensor Operating voltage range Operating voltage range 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 26.4 V 24 V 14 V 0.5 0 10 20 1.0 30 Airflow 1.5 40 50 Dimensions (unit: mm) (m3/min) (inch H2O) (Pa) 30 0.08 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 24 V 0.06 14 V 20 26.4 V 24 V 15 0.05 0.04 14 V 10 0.03 0.02 5 0.01 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 60 (CFM) 26.4 V 0.07 Static pressure 0.14 0.12 Static pressure Static pressure 40 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.16 9S0924L401 With pulse sensor DC Fan 92 mm sq. 9S0924F401 DC Airflow - Static Pressure Characteristics 10 20 30 Airflow 40 50 (CFM) 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 10 20 30 Airflow 40 (CFM) (With ribs) 4-o4.30.3 Mounting hole (4) 250.5 (4) 920.5 82.50.3 Lead wire AWG24 UL 1007 +50 300 0 (10) 82.50.3 920.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 90.5 90.5 o1 82.50.3 02 4-o4.5 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 151 DC Fan 92x92x32 mm San Ace 92 9G type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 170 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9G0912A201 9G0912S201 9G0912H201 9G0912M201 9G0924A201 9G0924S201 9G0924H201 9G0924M201 9G0948A201 9G0948S201 9G0948H201 9G0948M201 12 24 48 [V] 10.2 to 13.8 20.4 to 27.6 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.58 0.38 0.23 0.13 0.3 0.19 0.12 0.08 0.16 0.11 0.08 0.05 6.96 4.56 2.76 1.56 7.2 4.56 2.88 1.92 7.68 5.28 3.84 2.4 4300 3500 2850 2100 4300 3500 2850 2100 4300 3500 2850 2100 2.5 2.0 1.59 1.2 2.5 2.0 1.59 1.2 2.5 2.0 1.59 1.2 88.3 70.7 56.2 42.4 88.3 70.7 56.2 42.4 88.3 70.7 56.2 42.4 115 77 51 27 115 77 51 27 115 77 51 27 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.462 0.309 0.205 0.108 0.462 0.309 0.205 0.108 0.462 0.309 0.205 0.108 [C] 44 38 32 25 44 38 32 25 44 38 32 25 [h] -20 to +70 -20 to +60 40000/60C -20 to +70 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 568. PWM control Airflow - Static Pressure Characteristics 9G0912A201 9G0912S201 With pulse sensor Operating voltage range Operating voltage range 120 0.4 100 0.3 80 0.2 13.8 V 0.4 100 12 V 10.2 V 60 40 0.1 20 0 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 10 20 30 40 50 60 70 80 90 100 110 (CFM) Airflow 152 0.3 0.2 0.1 0 (inch H2O) (Pa) 120 0.30 13.8 V 12 V 80 Static pressure 0.5 140 Static pressure Static pressure 0.6 0.5 10.2 V 60 40 20 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 160 9G0912H201 With pulse sensor 0.25 80 13.8 V 60 10.2 V 0.20 0.15 0.10 12 V 40 20 0.05 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 90 (CFM) Airflow 0 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 40 160 30 10.2 V 1.00 0.75 0.50 20 10 0.25 0 0 0.5 0 9G0924H201 10 1.0 20 30 Airflow 1.5 40 50 (m3/min) (inch H2O) (Pa) 0.5 27.6 V 140 0.5 120 0.4 100 0.3 80 20.4 V 60 0.2 40 0.1 20 0 0 0.5 1.0 1.5 2.0 2.5 3.0 60 (CFM) Operating voltage range (inch H2O) (Pa) 40 0.10 Static pressure Static pressure 60 20.4 V 0.20 0.15 1.50 27.6 V 24 V 40 20 0.05 0 0.5 1.0 1.5 Airflow 9G0948S201 0.2 0.1 0 30 20.4 V 0.75 0.50 20 10 0.30 55.2 V 48 V 80 40.8 V 60 40 20 0 0 0.5 10 1.0 20 30 Airflow 40 1.5 50 (m3/min) 0.25 0.15 0.10 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 90 (CFM) Airflow 0 1.5 2.0 2.5 (m3/min) With pulse sensor 120 0.4 100 0.3 80 48 V 40.8 V 60 0.2 40 0.1 20 0 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) 1.50 55.2 V 60 55.2 V 140 0.5 9G0948M201 With pulse sensor 48 V 40.8 V 40 20 0.05 0.5 1.0 0 10 20 30 40 50 60 70 80 90 100 110 (CFM) 80 0.20 160 60 (CFM) (inch H2O) (Pa) Static pressure Static pressure 0.3 0.5 Airflow 0.6 27.6 V 24 V 0 120 0.4 100 0 Operating voltage range Operating voltage range (inch H2O) (Pa) 20 (inch H2O) (Pa) 9G0948H201 With pulse sensor 40 9G0948A201 With pulse sensor 1.00 (CFM) Operating voltage range 0.5 1.25 0 2.0 (m3/min) 0 10 20 30 40 50 60 70 0.1 20.4 V 60 0 10 20 30 40 50 60 70 80 90 (CFM) 0.25 0 0.2 0 (m3/min) Operating voltage range 80 0.25 0.3 24 V 80 Airflow (inch H2O) (Pa) 0.30 27.6 V 0 10 20 30 40 50 60 70 80 90 100 110 (CFM) 9G0924M201 With pulse sensor 120 0.4 100 24 V Static pressure 1.25 0.6 13.8 V 12 V Static pressure Static pressure 1.50 With pulse sensor Operating voltage range Static pressure Operating voltage range 9G0924S201 With pulse sensor DC Fan 92 mm sq. 9G0924A201 With pulse sensor Static pressure 9G0912M201 DC Airflow - Static Pressure Characteristics 1.25 40 55.2 V 48 V 30 40.8 V 1.00 0.75 0.50 20 10 0.25 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) 0 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) 60 (CFM) 153 Dimensions (unit: mm) (With ribs) 4-o4.30.3 Mounting hole Lead wire AWG24 UL 1007 920.5 82.50.3 +30 300 0 (10) 82.50.3 920.5 (4) (4) 320.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 82.50.3 4-o4.5 08 03 o1 90.5 82.50.3 90.5 o1 4-o4.5 82.50.3 82.50.3 90.5 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 154 Resin finger guards page: p. 539 DC DC Fan DC Fan 92 mm sq. 92x92x38 mm San Ace 92 9HV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 250 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 12 9HV0912P1G001 8 to 12.6 48 9HV0948P1G001 36 to 60 PWM duty cycle* [%] 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 5.2 0.8 1.2 0.15 62.4 9.6 57.6 7.2 14900 4500 14900 4500 5.1 1.54 5.1 1.54 180 54.4 180 54.4 1100 160 1100 160 [inchHO] 4.42 0.64 4.42 0.64 SPL Operating temperature Expected life [dB (A)] [C] [h] 72 44 72 44 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV0912P1G001 With pulse sensor with PWM control function 2.5 2.0 1.5 1.0 0.5 0 (inch H2O) (Pa) 12 VDC DC12 V 1000 PWM duty cycle PWM 100% 800 600 400 200 0 50% 0% 1 2 3 4 5 Airflow 9HV0948P1G001 400 10000 8000 6000 4000 200 2000 0 1 2 3 4 5 0 6 (m3/min) 0 20 40 60 80 100 120 140160 180 200 Airflow Static pressure Static pressure 50% 0% 1 14900 min-1 12000 8V 1200 PWM duty cycle PWM 100% 400 0 12 V 600 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 800 (inch H2O) (Pa) 48 VDC DC48 V 600 200 12.6 V 1000 100 (%) PWM PWM duty cycle (CFM) Operating voltage range 1200 0.5 0 16000 With pulse sensor with PWM control function (inch H2O) (Pa) 2.5 2.0 1.5 1.0 (min-1) PWM100% PWM duty cycle 100% 1200 (CFM) PWM duty cycle 4.5 4.0 1000 3.5 800 3.0 2.5 2.0 1.5 1.0 0.5 0 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 4.5 4.0 3.5 3.0 PWM duty - Speed characteristics example 2 3 4 5 0 20 40 60 80 100 120 140160 180 200 Airflow 6 (m3/min) (CFM) 4.5 4.0 1000 3.5 800 3.0 2.5 2.0 1.5 1.0 0.5 0 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 16000 60 V 14000 48 V 36 V 600 400 14900 min-1 10000 8000 6000 4000 200 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 12000 Fan speed 4.5 4.0 3.5 3.0 (Pa) 1200 Static pressure Static pressure (inch H2O) Operating voltage range Fan speed PWM duty cycle 2000 1 2 3 4 5 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 Airflow (CFM) 0 100 (%) PWM PWM duty cycle 155 Dimensions (unit: mm) (With ribs) 920.5 82.50.3 4-o4.50.3 Mounting hole 300 +50 0 (10) Lead wire AWG22 UL 3266 82.50.3 920.5 (4) (4) 380.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 90.5 4-o4.5 4-o4.5 05 o1 90.5 90.5 82.50.3 82.50.3 7 o9 82.50.3 90.5 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 156 Resin finger guards page: p. 539 DC DC Fan DC Fan 92 mm sq. 92x92x38 mm San Ace 92 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 240 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GA0912P1H03 12 10.2 to 13.8 9GA0924P1H01 24 20.4 to 27.6 48 40.8 to 55.2 9GA0948P1H03** * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.1 0.16 1.1 0.07 0.55 25.2 1.92 26.4 1.68 26.4 9700 2500 9700 2500 9700 4.0 0.97 4.0 0.97 4.0 141 34.3 141 34.3 141 500 33 500 33 500 [inchHO] 2.01 0.13 2.01 0.13 2.01 SPL Operating temperature Expected life [dB (A)] [C] [h] 63 29 63 29 63 -20 to +70 -10 to +70 40000/60C (70000/40C) -20 to +70 ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 572. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 2.5 600 2.0 500 PWM PWM duty cycle 100% 1.5 400 1.0 0.5 0 300 50% 200 100 0 0% 1 2 3 4 5 (m3/min) 0 20 40 60 80 100120 140160 180 (CFM) Airflow 0 10.2 V 300 200 1 2 3 9700 min-1 6000 4000 2000 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8000 13.8 V 12 V 1.5 400 0.5 10000 600 2.0 500 1.0 (min-1) PWM duty cycle 100% PWM100% 700 Static pressure Static pressure 2.5 (inch H2O) (Pa) 12 VDC DC12 V 700 PWM duty - Speed characteristics example Fan speed 9GA0912P1H03 4 5 (m3/min) 0 20 40 60 80 100 120 140 160180 (CFM) 0 2500 min-1 100 (%) PWM duty cycle PWM Airflow 157 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA0924P1H01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 2.5 600 2.0 500 PWM PWM duty cycle 100% 1.5 400 0.5 300 50% 200 100 0 0 0% 1 2 3 4 5 600 1.5 400 0.5 (m3/min) 200 0 1.5 (inch H2O) (Pa) DC48 V 48 VDC PWM duty cycle PWM 100% 400 300 1.0 0.5 0 200 50% 100 0 1 0 4 5 2 50 3 100 Airflow 4 5 (m3/min) 150 Dimensions (unit: mm) 100 (%) PWM duty cycle PWM 2.5 600 2.0 500 1.5 1.0 0.5 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 10000 48 V 40.8 V 300 200 0 1 0 (CFM) 2 50 3 100 Airflow 4 150 5 (m3/min) (CFM) AWG24 UL 1430 920.5 82.50.3 4000 0 Lead wire +30 300 0 (10) (4) Rotating direction 6000 (4) 380.5 Airflow direction 100 (%) PWM duty cycle PWM (With ribs) 82.50.3 920.5 9700 min-1 2000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 55.2 V 400 4-o4.50.3 Mounting hole 158 0 (m3/min) 2500 min-1 Airflow Static pressure Static pressure 500 3 Operating voltage range (inch H2O) (Pa) 2.0 4000 With pulse sensor with PWM control function PWM duty cycle 600 2 0 20 40 60 80 100 120 140 160180 (CFM) Airflow 2.5 1 9700 min-1 6000 2000 100 0 20 40 60 80 100120 140160 180 (CFM) 9GA0948P1H03 20.4 V 300 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8000 27.6 V 24 V 2.0 500 1.0 10000 Fan speed 1.0 (min-1) PWM duty cycle 100% PWM100% 700 Static pressure Static pressure 2.5 (inch H2O) (Pa) 24 VDC DC24 V 700 PWM duty - Speed characteristics example Fan speed PWM duty cycle Outlet side 82.50.3 4-o4.5 08 o1 90.5 90.5 82.50.3 03 o1 4-o4.5 90.5 82.50.3 82.50.3 DC Fan 92 mm sq. Inlet side DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 159 DC Fan 92x92x38 mm San Ace 92 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 250 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 10.8 to 13.2 9GV0912P1G03 12 9GV0912P1H03 10.2 to 13.8 9GV0912P1F03 9GV0948P1H03 48 40.8 to 55.2 9GV0948P1F03 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 0 100 0 100 0 Max. airflow [A] [W] [min-1] [m/min] [CFM] 4.1 0.33 3.5 0.29 1.9 0.16 0.82 0.14 0.48 0.12 49.2 4.0 42.0 3.5 22.8 1.92 39.4 6.7 23.04 5.76 9000 2900 8500 2700 7000 2200 8500 4000 7000 3500 5.35 1.72 5.05 1.6 4.15 1.3 5.05 2.37 4.15 2.07 189.0 60.8 178.0 56.5 146.6 45.9 178.0 83.7 146.6 73.1 Max. static pressure [Pa] 430.0 44.6 385.0 38.8 261 25.7 385.0 85.2 261 65.2 [inchHO] 1.73 0.18 1.55 0.16 1.05 0.1 1.55 0.34 1.05 0.26 SPL Operating temperature Expected life [dB (A)] [C] [h] 68 37 64 34 59 31 64 45 59 42 -20 to +70 -10 to +70 40000/60C -20 to +70 -10 to +70 * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 574. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range 2.02.0 1.81.8 1.61.6 1.41.4 1.21.2 1.01.0 0.80.8 0.60.6 0.40.4 0.20.2 00 500 500 450 450 400 400 350 350 300 300 250 250 200 200 150 150 100 100 5050 PWM duty cycle PWM PWM 100% 100% 50% 50% 0% 0% /min) /min) 6 (m 0 0 1 1 2 2 3 3 4 4 5 5 6 (m 3 00 160 (inch H2O)(Pa) (Pa) (inch H2O) 12 VDC DC12 DC12 V V 3 (CFM) (CFM) 100 150 200 150 200 5050 100 Airflow 2.02.0 1.81.8 1.61.6 1.41.4 1.21.2 1.01.0 0.80.8 0.60.6 0.40.4 0.20.2 00 Static pressure Static pressure (inch H2O)(Pa) (Pa) (inch H2O) 500 500 450 450 400 400 350 350 300 300 250 250 200 200 150 150 100 100 5050 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 9000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 9000 min-1 8000 13.2 13.2 VV 7000 1212 VV Fan speed 9GV0912P1G03 10.8 10.8 VV 6000 5000 4000 3000 2900 min-1 2000 1000 /min) 6 (m /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 (m 150 200 100 150 200(CFM) 0 0 5050 100 (CFM) 3 Airflow 3 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range 1.81.8 450450 1.61.6 400400 1.41.4 350350 50% 50% 1.21.2 300300 1.01.0 250250 0.80.8 200200 0 0 /min) 6 (m /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 (m (CFM) (CFM) 0 0 5050 100100 150150 200200 3 3 Airflow 9GV0912P1F03 0.8 200 0.6 150 0.4 100 0.2 0 (inch H2O) (Pa) 12 VDC DC12 V PWM PWM duty cycle 100% 0% 50 0 1 0 2 50 9GV0948P1H03 3 100 4 5 150 200 Airflow 1.2 300 13.8 V 1.0 250 12 V 0.8 200 0.6 150 0.4 100 0.2 50 PWM PWM duty cycle PWM 100% 100% 1.21.2 300300 1.01.0 250250 0.80.8 200200 50% 50% 0% 0% 9GV0948P1F03 0 0 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 4000 3000 3 100 4 5 6 (m3/min) 150 200 (CFM) 100 (%) 0 PWM duty cycle PWM Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 9000 8500 min-1 8000 55.2 55.2 VV 4848 VV 40.8 40.8 VV Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 6000 5000 4000 4000 min-1 3000 2000 1000 3 /min) 6 3(m /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 (m (CFM) 0 0 5050 100100 150150 200200(CFM) 100 (%) 0 PWM duty cycle PWM Airflow With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 48 VDC DC48 V PWM duty cycle PWM 100% Static pressure Static pressure 250 2 50 0.40.4 100100 0.20.2 5050 (inch H2O) (Pa) 1.0 1 0.80.8 200200 0.60.6 150150 PWM duty cycle 300 5000 1000 1.41.4 350350 1.21.2 300300 1.01.0 250250 Airflow 1.2 7000 min-1 6000 -1 2000 2200 min 1.81.8 450450 1.61.6 400400 3 /min) 6 3(m /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 (m (CFM) (CFM) 0 0 5050 100100 150150 200200 350 9000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 10.2 V (inch H2O)(Pa) (Pa) (inch H2O) 48 VDC DC48 DC48 V V 1.81.8 450450 1.61.6 400400 1.41.4 350350 1.4 0 0 (CFM) (min-1) 8000 Operating voltage range Static pressure 350 With pulse sensor with PWM control function (inch H2O) (Pa) (inch H2O) (Pa) 0 0 100 (%) PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.4 0 6 (m3/min) PWM duty cycle 0.60.6 150150 0.40.4 100100 0.20.2 5050 3000 2700 min-1 2000 PWM duty cycle PWM Fan speed 250 4000 0 3 Fan speed 1.0 5000 Airflow Static pressure 300 /min) 6 (m /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 (m (CFM) 0 0 5050 100100 150150 200200(CFM) Static pressure Static pressure 350 6000 1000 3 Operating voltage range (inch H2O) (Pa) 1.2 10.2 10.2 VV With pulse sensor with PWM control function PWM duty cycle 1.4 8500 min-1 7000 0.60.6 150150 0.40.4 100100 0.20.2 5050 0% 0% Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8000 0% 1 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 9000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 55.2 V 7000 48 V 6000 40.8 V Fan speed 0.60.6 150150 0.40.4 100100 0.20.2 5050 9000 13.8 13.8 VV 1212 VV Static pressure 100% 100% (min-1) PWM duty cycle 100% PWM100% PWM100% 1.81.8 450450 1.61.6 400400 1.41.4 350350 PWM PWM PWM duty cycle 1.21.2 300300 1.01.0 250250 0.80.8 200200 0 0 (inch H2O)(Pa) (Pa) (inch H2O) 12DC12 VDC DC12 V V Static pressure (inch H2O)(Pa) (Pa) (inch H2O) PWM duty - Speed characteristics example Fan speed PWM duty cycle 7000 min-1 5000 4000 3000 3500 min-1 2000 1000 0 0 1 2 50 3 100 4 5 6 (m3/min) 150 200 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 161 DC Fan 92 mm sq. 9GV0912P1H03 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) (With ribs) 4-o4.30.3 Mounting hole 82.50.3 920.5 Lead wire AWG24 UL 1430 +30 300 0 (10) (4) 82.50.3 (4) 380.5 920.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Outlet side Inlet side 82.50.3 4-o4.5 08 o1 90.5 90.5 82.50.3 03 o1 4-o4.5 90.5 82.50.3 82.50.3 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 162 Resin finger guards page: p. 539 DC DC Fan DC Fan 92 mm sq. 92x92x38 mm San Ace 92 9G type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 180 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input [V] 9G0912G101 9G0912H101 9G0924G101 9G0924H101 9G0948J101 9G0948G101 9G0948H101 [V] 12 7.0 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.1 0.58 0.55 0.3 0.32 0.27 0.16 13.2 6.96 13.2 7.2 15.36 12.96 7.68 5000 4000 5000 4000 5500 5000 4000 3.1 2.54 3.1 2.54 3.41 3.1 2.54 110 90 110 90 120.49 110 90 150 100 150 100 178 150 100 SPL [inchHO] [dB (A)] 0.602 0.402 0.602 0.402 0.715 0.602 0.402 50 43 50 43 55 50 43 Operating temperature Expected life [C] [h] -20 to +60 40000/60C -20 to +70 -20 to +60 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 568. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9G0912G101 9G0912H101 With pulse sensor Operating voltage range 9G0924G101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 160 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 (m3/min) 0 20 40 60 80 100 120 Airflow (CFM) 140 13.8 V 0.5 120 12 V 0.4 100 0.3 0.2 Static pressure 13.8 V 12 V 7V Static pressure Static pressure (inch H2O) (Pa) 0.6 80 7V 60 40 0.1 20 0 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 20 40 60 Airflow With pulse sensor 80 100 (CFM) 27.6 V 24 V 20.4 V 0.5 1.0 1.5 2.0 2.5 3.0 3.5 (m3/min) 0 20 40 60 80 100 120 Airflow (CFM) 163 Airflow - Static Pressure Characteristics 9G0924H101 9G0948J101 With pulse sensor Operating voltage range With pulse sensor Operating voltage range 9G0948G101 Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 160 1.0 220 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 0.5 120 24 V 0.4 100 0.3 0.2 20.4 V 80 60 40 0.1 20 0 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 20 9G0948H101 40 60 Airflow 80 100 55.2 V 48 V 40.8 V 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 (m3/min) 0 20 40 60 80 100 120 140 (CFM) (CFM) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.6 160 55.2 V 140 0.5 120 48 V 0.4 100 0.3 0.2 40.8 V 80 60 40 0.1 20 0 0 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 20 40 60 Airflow 80 100 Dimensions (unit: mm) 4-o4.30.3 Mounting hole (CFM) (With ribs) Lead wire AWG24 UL 1007 920.5 82.50.3 +30 300 0 (10) 82.50.3 920.5 Rotating direction 164 (4) (4) 380.5 Airflow direction Static pressure 27.6 V 140 Static pressure Static pressure 0.6 With pulse sensor 55.2 V 48 V 40.8 V 0.5 1.0 1.5 2.0 2.5 3.0 3.5 (m3/min) 0 20 40 60 80 100 120 Airflow (CFM) 82.50.3 4-o4.5 90.5 82.50.3 o1 90.5 82.50.3 90.5 4-o4.5 08 03 o1 DC Fan 92 mm sq. Outlet side Inlet side 82.50.3 DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 165 DC Fan 120x120x25 mm San Ace 120 9GA type Low Power Consumption Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 280 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range [V] [V] 9GA1212P4G001 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 53 9GA1212P4S001 9GA1224P4G001 9GA1224P4S001 9GA1248P4G001 9GA1248P4S001 PWM duty cycle* [%] 100 25 100 25 100 25 100 25 100 25 100 25 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.93 0.16 0.61 0.16 0.47 0.1 0.31 0.1 0.24 0.08 0.16 0.08 11.16 1.92 7.32 1.92 11.28 2.4 7.44 2.4 11.52 3.84 7.68 3.84 6400 2550 5400 2550 6400 2550 5400 2550 6400 2550 5400 2550 3.8 1.5 3.2 1.5 3.8 1.5 3.2 1.5 3.8 1.5 3.2 1.5 134 53 113 53 134 53 113 53 134 53 113 53 365 60 260 60 365 60 260 60 365 60 260 60 [inchHO] 1.47 0.24 1.04 0.24 1.47 0.24 1.04 0.24 1.47 0.24 1.04 0.24 SPL Operating temperature Expected life [dB (A)] [C] [h] 57 34 54 34 57 34 54 34 57 34 54 34 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Pulse sensor Differs according to the model. Refer to the table on pp. 572 to 573. Without sensor Lock sensor The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. 9GA1212G4001 9GA1212S4001 9GA1224G4001 9GA1224S4001 9GA1248G4001 9GA1248S4001 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] [V] 12 7 to 13.8 24 14 to 27.6 48 36 to 53 Max. airflow [W] [min-1] [m/min] [CFM] [Pa] 0.93 0.61 0.47 0.31 0.24 0.16 11.16 7.32 11.28 7.44 11.52 7.68 6400 5400 6400 5400 6400 5400 3.8 3.2 3.8 3.2 3.8 3.2 134 113 134 113 134 113 365 260 365 260 365 260 The following sensor and control options are available for selection. Available for all models. PWM control Differs according to the model. Refer to the table on pp. 572 to 573. Without sensor 166 Max. static pressure [A] Lock sensor [inchHO] 1.47 1.04 1.47 1.04 1.47 1.04 SPL Operating temperature Expected life [dB (A)] [C] [h] 57 54 57 54 57 54 -20 to +70 40000/60C (70000/40C) With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 100% 300 1.0 0 100 25% 0 1 2 3 4 5 1.0 200 0.5 0 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) 0 100% 50% 150 100 25% 50 0 350 1.25 300 Static pressure Static pressure 0.25 1 2 3 4 5 0.75 0.50 0.25 0 (m3/min) 9GA1224P4G001 Static pressure Static pressure 1.0 50% 100 25% 1 2 3 4 5 1.5 9GA1224P4S001 0 0 3 4 5 4000 3000 2000 0 (m3/min) 100 (%) PWM PWM duty cycle PWM duty - Speed characteristics example (min-1) 7000 0.5 24 V 100 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6400 min-1 6000 27.6 V 20.4 V 5000 4000 3000 2000 1000 1 2 3 4 5 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow 350 50% 25% 1 2 PWM duty cycle 100% PWM100% 400 1.25 300 PWM PWM duty cycle 100% 50 1 (inch H2O) (Pa) 24 VDC DC24 V 100 5400 min-1 5000 1000 0 20 40 60 80 100 120 140 160 180 (CFM) Static pressure Static pressure 0.25 50 Operating voltage range 350 0.50 6000 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 150 7000 200 0 (m3/min) PWM duty cycle 0.75 200 (min-1) 10.2 V 150 1.0 Airflow 1.00 250 PWM duty - Speed characteristics example 200 300 0 20 40 60 80 100 120 140 160 180 (CFM) 300 100 (%) PWM duty cycle PWM 12 V 2.0 500 300 1.25 2000 0 (m3/min) 13.8 V (inch H2O) (Pa) PWM PWM duty cycle 100% 0 5 Airflow 24 VDC DC24 V 2.0 500 0 4 Operating voltage range (inch H2O) (Pa) 0.5 3000 With pulse sensor with PWM control function PWM duty cycle 200 3 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 1.5 2 PWM duty cycle 100% PWM100% 1.00 250 0 20 40 60 80 100 120 140 160 180 (CFM) 400 1 (inch H2O) (Pa) PWM PWM duty cycle 0.75 200 0.50 4000 Airflow 12 VDCV DC12 350 1.00 250 5000 1000 Operating voltage range (inch H2O) (Pa) 300 0 6400 min-1 With pulse sensor with PWM control function PWM duty cycle 1.25 100 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 9GA1212P4S001 10.2 V Fan speed 0.5 50% 12 V 300 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 13.8 V 400 Fan speed 200 1.5 7000 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 0.50 0.25 0 (min-1) PWM duty cycle 100% PWM100% 7000 27.6 V 200 20.4 V 150 100 5000 5400 min-1 4000 3000 2000 1000 50 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 24 V 1.00 250 0.75 PWM duty - Speed characteristics example Fan speed 400 (min-1) PWM duty cycle 100% PWM100% 2.0 500 Static pressure Static pressure 1.5 (inch H2O) (Pa) 12 VDC DC12 V 2.0 500 PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 167 DC Fan 120 mm sq. 9GA1212P4G001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GA1248P4G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM duty cycle PWM 100% 300 1.0 0 100 25% 0 1 2 3 4 5 1.0 40.8 V 200 0 (m3/min) 48 V 300 0.5 0 1 2 PWM PWM duty cycle 100% 0 50% 150 100 25% 50 0 Static pressure Static pressure 0.25 1 2 3 4 5 0.75 0.50 0.25 0 (m3/min) 9GA1212G4001 Static pressure Static pressure 13.8 V 12 V 200 7V 1 2 9GA1224S4001 3 4 5 0.50 0.25 0 (m3/min) 14 V 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 168 1.5 3 4 5 100 (%) 0 (m3/min) PWM duty cycle PWM 9GA1224G4001 With pulse sensor (inch H2O) (Pa) 300 2.0 500 12 V 150 100 7V 1.5 1 2 3 4 5 200 0.5 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow With pulse sensor (inch H2O) (Pa) 350 400 1.25 48 V 36 V 100 0 0 Operating voltage range 200 0 14 V 100 9GA1248S4001 With pulse sensor 300 0.5 24 V 1.0 0 (m3/min) 27.6 V 400 300 50 0 With pulse sensor Operating voltage range 13.8 V 1.0 50 0 2 53 V 150 2000 Airflow Static pressure Static pressure 0 1 2.0 500 0.75 200 3000 1000 (inch H2O) (Pa) 24 V 4000 0 20 40 60 80 100 120 140 160 180 (CFM) 27.6 V 1.00 250 100 0 5400 min-1 5000 50 Operating voltage range (inch H2O) (Pa) 0.25 100 9GA1248G4001 With pulse sensor Operating voltage range 0.50 40.8 V 0.75 200 Airflow 300 6000 150 1.00 250 0 20 40 60 80 100 120 140 160 180 (CFM) 1.25 7000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 Airflow 1.25 1.0 350 200 350 300 0 (min-1) (inch H2O) (Pa) 2.0 500 0 PWM duty - Speed characteristics example Operating voltage range (inch H2O) (Pa) 100 PWM duty cycle PWM 48 V 9GA1212S4001 With pulse sensor Operating voltage range 400 100 (%) 0 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 0.5 5 53 V 300 1.00 250 0 20 40 60 80 100 120 140 160 180 (CFM) 1.5 4 PWM duty cycle 100% PWM100% 350 1.25 0.75 200 0.50 3 Airflow (inch H2O) (Pa) 48 VDC DC48 V 350 1.00 250 2000 1000 Operating voltage range (inch H2O) (Pa) 300 3000 With pulse sensor with PWM control function PWM duty cycle 1.25 4000 100 Airflow 9GA1248P4S001 6400 min-1 5000 0 20 40 60 80 100 120 140 160 180 (CFM) 0 20 40 60 80 100 120 140 160 180 (CFM) Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 0.5 50% 400 Static pressure 200 1.5 7000 53 V Static pressure 400 (min-1) PWM duty cycle 100% PWM100% 2.0 500 Static pressure Static pressure 2.0 500 1.5 (inch H2O) (Pa) 48 VDC DC48 V PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 300 53 V 48 V 1.00 250 0.75 0.50 0.25 0 200 36 V 150 100 50 0 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 25.40.5 (5) 104.80.3 1200.8 4-o4.50.3 Mounting hole DC (With pulse sensor with PWM control function) (5) DC Fan 120 mm sq. Dimensions (unit: mm) +30 300 0 (10) Lead wire 104.80.3 AWG24 UL 1007 1200.8 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 104.80.3 4-o4.5 35 27 o1 104.80.3 118 104.80.3 o1 118 4-o4.5 118 118 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1000G page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 169 DC Fan 120x120x25 mm San Ace 120 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 260 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GV1212P4G01 12 10.2 to 13.8 9GV1224P4G01 24 20.4 to 27.6 40.8 to 55.2 9GV1248P4J01 48 9GV1248P4G01 40.8 to 60.0 9GV1248P4H01 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 0 100 0 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.68 0.18 0.84 0.13 0.5 0.15 0.42 0.07 0.33 0.07 20.16 2.16 20.16 3.12 24.0 7.2 20.16 3.36 15.84 3.36 5100 1650 5100 1650 5400 3000 5100 1650 4600 1650 4.83 1.56 4.83 1.56 5.11 2.84 4.83 1.56 4.35 1.56 171 55.1 171 55.1 180 100 171 55.1 154 55.1 224 23.5 224 23.5 251 77.5 224 23.5 182 23.5 [inchHO] 0.9 0.09 0.9 0.09 1.01 0.31 0.9 0.09 0.73 0.09 SPL Operating temperature Expected life [dB (A)] [C] [h] 58 30 58 30 59 47 58 30 55 30 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 575. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) DC12 V V 12 DC12 VDC 1.21.2 300300 0.80.8 200200 PWM duty cycle PWM PWM 100% 100% Static pressure 1.01.0 250250 0.20.2 5050 0 0 0 0 0 0 170 1.21.2 300300 1.01.0 250250 0.80.8 200200 0.60.6 150150 0.60.6 150150 0.40.4 100100 (inch H2O) (Pa) (inch H2O) (Pa) 50% 50% 0% 0% 3 /min) 1 1 2 2 3 3 4 4 5 5 6 (m /min) 6 3(m 5050 100100 150150 200200(CFM) (CFM) Airflow 0 0 6000 13.8 VV 13.8 1212 VV 10.2 VV 10.2 0.20.2 5050 0 0 (min-1) PWM100% PWM duty cycle 100% PWM100% 0.40.4 100100 0 0 PWM duty - Speed characteristics example (CFM) 5050 100100 150150 200200 (CFM) Airflow 5100 min-1 4000 3000 2000 1000 3 3 /min) /min) 1 1 2 2 3 3 4 4 5 5 6 (m 6 (m Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 Fan speed PWM duty cycle Static pressure 9GV1212P4G01 0 1650 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range 0.8 200 0.6 150 0.4 100 0.2 50 50% 0% 0 1 0 2 50 9GV1248P4J01 3 100 4 5 150 200 Airflow 0.8 200 0.6 150 0.4 100 0.2 50 0 0 50% 0% 1 2 50 9GV1248P4G01 3 4 100 5 150 Airflow 6 (m3/min) DC48 48 VDC DC48 VV Static pressure 250 1.01.0 250 PWM duty cycle PWM PWM 100% 100% 200 0.80.8 200 50% 50% 100 0.40.4 100 1.2 300 4 150 Airflow 5 6 (m3/min) 200 2000 1650 min-1 100 (%) 0 PWM duty cycle PWM (CFM) 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 PWM duty - Speed characteristics example (min-1) 6000 55.2 V Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 5400 min-1 5000 48 V 40.8 V 4000 3000 3000 min-1 2000 1000 1 (inch H2O) (Pa) (Pa) (inch H2O) 300 1.21.2 300 250 1.01.0 250 200 0.80.8 200 00 3 3 /min) /min) 6 (m 1 1 2 2 3 3 4 4 5 5 6 (m (CFM) 100 150 150 200 200(CFM) 5050 100 00 00 Airflow 2 50 4 5 6 150 200 3 100 100 (%) 0 (m3/min) PWM duty cycle PWM (CFM) Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 6000 6060 VV Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 5100 min-1 5000 4848 VV 40.8 40.8 VV 4000 3000 2000 1650 min-1 1000 3 3 /min) /min) 1 1 2 2 3 3 4 4 5 5 6 6(m(m 100 (%) 0 PWM duty cycle PWM (CFM) 100 150 150 200 200(CFM) 5050 100 Airflow With pulse sensor with PWM control function Operating voltage range 48 VDC DC48 V V DC48 1.21.2 300300 1.01.0 250250 (inch H2O) (inch H2O)(Pa)(Pa) 1.21.2 300300 1.01.0 250250 0.80.8 200200 PWM duty cycle PWM PWM 100% 100% Static pressure 3 100 0.20.2 5050 (inch H2O) (inch H2O)(Pa)(Pa) 0.60.6 150150 0 0 2 50 PWM duty cycle 100% PWM100% 0 0% 0% 9GV1248P4H01 0 0 1 100 0.40.4 100 PWM duty cycle 0.20.2 50 50 0 3000 1000 150 0.60.6 150 150 0.60.6 150 0.40.4 100100 50 Operating voltage range 300 1.21.2 300 00 0.2 4000 With pulse sensor with PWM control function (inch H2O)(Pa) (Pa) (inch H2O) 00 100 200 (CFM) PWM duty cycle 00 0.4 (inch H2O) (Pa) PWM duty cycle PWM 100% 0.20.2 5050 150 27.6 V 24 V 20.4 V Operating voltage range 48 VDC DC48 V 0 0.6 5100 min-1 5000 0 Static pressure 250 200 Static pressure Static pressure 1.0 0.8 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 300 250 (CFM) PWM duty cycle 1.2 1.0 0 6 (m3/min) 50% 50% 0% 0% 3 /min) /min) 1 1 2 2 3 3 4 4 5 5 6 (m 6 3(m (CFM) (CFM) 0 0 50 50 100100 150150 200200 Airflow 0.80.8 200200 0 PWM PWM duty cycle 100% 6000 Fan speed 250 300 Fan speed 1.0 1.2 (min-1) PWM duty cycle 100% PWM100% 6000 4848 VV 40.8 VV 40.8 Voltage: 48 VDC DC48 V PWM frequency: kHz 25 kHz PWM25 5000 6060 VV 4600 min-1 4000 3000 2000 1650 min-1 1000 0.20.2 50 50 0 0 (min-1) PWM duty cycle 100% PWM100% PWM100% 0.60.6 150150 0.40.4 100100 PWM duty - Speed characteristics example Fan speed 300 Static pressure 1.2 (inch H2O) (Pa) DC24 V 24 VDC Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 0 1 1 2 2 3 3 4 4 5 5 6 (m 3 /min) /min) 6 3(m (CFM) 0 0 50 50 100100 150150 200200(CFM) 0 100 (%) PWM duty cycle PWM Airflow 171 DC Fan 120 mm sq. 9GV1224P4G01 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) (With ribs) 4-o4.50.3 (5) 25.40.5 (5) Lead wire AWG24 UL 1007 104.80.3 1200.8 Mounting hole +30 300 0 (10) 104.80.3 1200.8 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side 104.80.3 4-o4.5 35 o1 118 118 104.80.3 27 o1 4-o4.5 118 104.80.3 104.80.3 Outlet side 118 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 172 Resin finger guards Model no.: 109-1000G page: p. 539 DC DC Fan San Ace 120 9G type DC Fan 120 mm sq. 120x120x25 mm Model 9G1212B401 is not certified. General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 240 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9G1212G401 9 G 1 2 1 2 E 4 01 9G1212A401 9G1212H401 9 G 1 2 1 2 F 4 01 9G1212M401 9G1212B401 9G1224G401 9 G 1 2 2 4 E 4 01 9G1224A401 9G1224H401 9 G 1 2 2 4 F 4 01 9G1224M401 9G1248G401 9 G 1 2 4 8 E 4 01 9G1248A401 9G1248H401 9 G 1 2 4 8 F 4 01 9G1248M401 [V] 10.2 to 13.8 12 6 to 13.8 7 to 13.8 10.2 to 13.8 20.4 to 27.6 24 12 to 27.6 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.9 0.58 0.4 0.31 0.19 0.14 0.06 0.47 0.37 0.21 0.17 0.1 0.08 0.23 0.16 0.13 0.1 0.06 0.05 10.8 6.96 4.8 3.72 2.28 1.68 0.72 11.28 8.88 5.04 4.08 2.4 1.92 11.04 7.68 6.24 4.8 2.88 2.4 4100 3650 3150 2850 2250 1950 1000 4100 3650 3150 2850 2250 1950 4100 3650 3150 2850 2250 1950 3.68 3.25 2.83 2.5 1.98 1.66 0.88 3.68 3.25 2.83 2.5 1.98 1.66 3.68 3.25 2.83 2.5 1.98 1.66 130 115 100 88 70 59 31 130 115 100 88 70 59 130 115 100 88 70 59 120 98 77 64 42 31 9.6 120 98 77 64 42 31 120 98 77 64 42 31 SPL [inchHO] 0.482 0.394 0.309 0.257 0.169 0.124 0.039 0.482 0.394 0.309 0.257 0.169 0.124 0.482 0.394 0.309 0.257 0.169 0.124 Operating temperature Expected life [dB (A)] [C] [h] 51 48 44 40 35 29 18 51 48 44 40 35 29 51 48 44 40 35 29 -20 to +70 40000/60C The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 568 to 570. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9G1212E401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) Static pressure 0.5 0.4 0.3 0.2 0.1 0 0.5 13.8 V 120 0.4 12 V 100 10.2 V 80 60 40 20 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0.3 0.2 0.1 0 (inch H2O) (Pa) 120 0.4 100 13.8 V 13.8 V 100 12 V 80 10.2 V 60 40 20 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 140 Static pressure 0.6 9G1212A401 With pulse sensor Static pressure 9G1212G401 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0.3 80 12 V 10.2 V 60 0.2 40 0.1 0 20 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 173 Airflow - Static Pressure Characteristics 9G1212H401 9G1212F401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 60 12 V 0.2 40 0.1 0 20 6V 0 1 0 9G1212B401 20 2 40 60 Airflow 3 (m3/min) 80 100 0.16 13.8 V 40 12 V 30 20 7V 10 0 0.5 1.0 1.5 2.0 2.5 0 10 20 30 40 50 60 70 80 90 Airflow 8 0.01 0 12 V 6 10.2 V 4 2 0 0.4 0 9G1224A401 10 20 30 Airflow 40 0.2 0.1 0 1.2 (m3/min) 0.8 0.3 40 20 0 Static pressure Static pressure 0.3 20.4 V 40 0 20 0 1 2 3 4 20 12 V 0 1 27.6 V 0.5 24 V 30 0.10 Static pressure Static pressure 0.14 0.08 20.4 V 20 0.06 0.04 10 0.02 0 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow 174 20 2 (CFM) 0.4 0.3 0.2 0.1 0 (CFM) 0.2 0.1 27.6 V 24 V 80 20.4 V 60 40 20 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 40 60 Airflow 3 (m3/min) 80 100 With pulse sensor 60 50 27.6 V 40 24 V 20.4 V 30 20 10 0 0.5 1.5 2.0 2.5 (m3/min) Airflow 9G1248E401 With pulse sensor 1.0 0 10 20 30 40 50 60 70 80 90 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.5 140 55.2 V 120 0.4 48 V 100 40.8 V 80 60 40 20 0 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 (CFM) (inch H2O) (Pa) 0.6 2.0 (m3/min) Operating voltage range 24 V 0 40 1.5 With pulse sensor 100 9G1224F401 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.3 0 (m3/min) 40 9G1248G401 With pulse sensor Operating voltage range 0.12 4 27.6 V Airflow 0.16 3 0.2 0 (m3/min) 1.0 (inch H2O) (Pa) 0 20 40 60 80 100 120 140 (CFM) 9G1224M401 2 60 0.1 0.5 120 Airflow 27.6 V 0.2 0.1 1 Operating voltage range 24 V 0 0 20 40 60 80 100 120 140 (CFM) 80 60 20.4 V 60 (inch H2O) (Pa) 80 0.4 24 V 80 100 0.3 0.5 27.6 V 100 (inch H2O) (Pa) 0.4 10 (inch H2O) (Pa) 120 9G1224H401 Operating voltage range 0.04 Operating voltage range 140 (CFM) With pulse sensor 0.06 9G1224E401 With pulse sensor Static pressure 0.03 0.4 7V 20 Airflow Static pressure 10 13.8 V Static pressure Static pressure 12 0.04 0.02 0.5 12 V 0 10 20 30 40 50 60 70 Static pressure 14 0.05 0.08 (CFM) (inch H2O) (Pa) 0.6 13.8 V 30 0.10 0 (m3/min) Operating voltage range (inch H2O) (Pa) 0.12 0.02 9G1224G401 Operating voltage range 40 0.14 50 (CFM) With pulse sensor (inch H2O) (Pa) 60 Static pressure 13.8 V 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 80 Static pressure Static pressure 0.3 9G1212M401 With pulse sensor 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0.3 0.2 0.1 0 120 55.2 V 100 48 V 80 40.8 V 60 40 20 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 100 80 0.3 0.3 55.2 V 80 48 V 40.8 V 60 0.2 40 0.1 0 20 0 1 2 3 4 48 V 40.8 V 40 0 (m3/min) 20 0 1 0 0 20 40 60 80 100 120 140 (CFM) Airflow 9G1248M401 Operating voltage range 55.2 V 0.2 0.1 With pulse sensor (inch H2O) (Pa) 60 Static pressure Static pressure 0.4 9G1248F401 With pulse sensor DC Fan 120 mm sq. 9G1248H401 With pulse sensor Static pressure 9G1248A401 DC Airflow - Static Pressure Characteristics 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 60 50 55.2 V 40 48 V 40.8 V 30 20 10 0 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 90 (CFM) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) 0.16 40 55.2 V Static pressure 0.14 0.12 48 V 30 0.10 0.08 40.8 V 20 0.06 0.04 10 0.02 0 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow Dimensions (unit: mm) (CFM) (With ribs) 4-o4.30.3 Mounting hole (10) 1190.5 104.80.3 +30 300 0 Lead wire AWG24 UL 1007 104.80.3 1190.5 Rotating direction (5) (5) +1 25 0 Airflow direction 175 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 117 104.80.3 o1 117 117 4-o4.5 34 104.80.3 26 o1 104.80.3 4-o4.5 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 176 Resin finger guards Model no.: 109-1000G page: p. 539 DC DC Fan DC Fan 120 mm sq. 120x120x25 mm San Ace 120 9S type Silent Fan General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 140 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. 9S1212H401 9S1212F401 9S1212M401 9S1212L401 9S1224M401 12 24 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 5.0 to 13.2 5.0 to 13.8 6.0 to 13.8 7.0 to 13.8 14 to 26.4 0.39 0.19 0.13 0.08 0.06 4.68 2.28 1.56 0.96 1.44 2700 2200 1850 1500 1850 2.45 2.0 1.66 1.36 1.66 86.5 70.6 58.6 48.1 58.6 45.2 30.0 22.7 14.9 22.7 [V] SPL [inchHO] 0.18 0.12 0.09 0.06 0.09 Operating temperature Expected life [dB (A)] [C] 36 30 24 17 24 -10 to +60 -10 to +70 [h] 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 578. Lock sensor PWM control Airflow - Static Pressure Characteristics 9S1212H401 9S1212F401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.15 50 13.2 V 40 12 V 30 0.10 0.05 0 20 5V 10 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 20 40 60 Airflow 80 100 (CFM) 0.15 (inch H2O) (Pa) 50 0.15 13.8 V 40 Static pressure 0.20 0.20 12 V 30 5V 0.10 20 0.05 0 10 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 60 Static pressure Static pressure 0.25 9S1212M401 With pulse sensor 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m3/min) (CFM) 40 30 13.8 V 0.10 12 V 20 0.05 0 6V 10 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 177 Airflow - Static Pressure Characteristics 9S1212L401 9S1224M401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 40 0.15 Static pressure Static pressure 0.15 30 13.8 V 12 V 0.10 20 7V 0.05 0 10 0 With pulse sensor 0.5 1.0 1.5 40 30 0.10 26.4 V 20 0.05 0 2.0 (m3/min) 10 0 14 V 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 (CFM) Airflow Dimensions (unit: mm) 24 V Airflow (CFM) (With ribs) 4-o4.30.3 Mounting hole 1190.5 104.80.3 Lead wire AWG24 UL 1007 (10) +30 300 0 (5) 104.80.3 1190.5 (5) +1 25 0 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Outlet side Inlet side 117 4-o4.5 104.80.3 34 o1 117 26 o1 104.80.3 4-o4.5 117 104.80.3 104.80.3 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 178 Resin finger guards Model no.: 109-1000G page: p. 539 DC DC Fan DC Fan 120 mm sq. 120x120x38 mm San Ace 120 9HV type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 460 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9HV1224P1A001 21.6 to 26.4 9HV1248P1G001 48 36 to 60 9HV1248P1H001 PWM duty cycle* [%] 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow [A] [W] [min-1] [m/min] 2.4 0.37 2.0 0.23 1.4 0.23 57.6 8.88 96 11 67 11 9600 3800 11500 3800 10000 3800 7.0 2.7 8.3 2.7 7.2 2.7 [CFM] 247 95 293 95 254 95 Max. static pressure [Pa] 950 161 1300 161 1050 161 [inchHO] 3.82 0.65 5.22 0.65 4.22 0.65 SPL Operating temperature Expected life [dB (A)] [C] [h] 71 46 75 46 72 46 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 575. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 3 2 1 0 800 1200 PWM PWM duty cycle 100% Static pressure Static pressure 4 1000 (inch H2O) (Pa) 24 VDC DC24 V 1200 600 400 200 0 0 50% 0% 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 Airflow (CFM) PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 4 1000 26.4 V 800 24 V 3 2 1 0 600 (min-1) 21.6 V 400 0 9600 min-1 8000 6000 4000 3800 min-1 2000 200 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 10000 Fan speed 9HV1224P1A001 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 Airflow (CFM) 0 100 (%) PWM duty cycle PWM 179 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV1248P1G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1400 PWM PWM duty cycle 100% 5 4 1000 3 2 1 0 800 600 50% 400 200 0 0 0% 50 100 150 200 250 300 Airflow 9HV1248P1H001 2 1 0 1200 PWM PWM duty cycle 100% 400 0 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 8000 6000 4000 3800 min-1 Airflow 100 (%) 0 (m3/min) PWM duty cycle PWM (CFM) 4 1000 50% 0% Airflow 2 1 0 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 3 800 PWM duty cycle 100% PWM100% (min-1) 400 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 1200.8 104.80.3 1200.8 Rotating direction Lead wire AWG24 UL 1430 6000 4000 Airflow 0 +30 300 0 104.80.3 8000 3800 min-1 6.50.3 3.50.3 AWG22 UL 3266 (Model 9HV1224P1A001 no.: 9HV1224P1A001 only) 100 (%) PWM duty cycle PWM (CFM) 8-o4.50.3 Mounting hole (10) 10000 min-1 2000 200 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 10000 60 V 36 V 48 V 600 0 (CFM) PWM duty - Speed characteristics example Dimensions (unit: mm) 180 11500 min-1 2000 200 (inch H2O) (Pa) 48 VDC DC48 V 600 0 36 V 400 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 10000 Operating voltage range 800 200 1 48 V 60 V 600 0 Static pressure Static pressure 3 2 800 12000 With pulse sensor with PWM control function (inch H2O) (Pa) 4 1000 3 (CFM) PWM duty cycle 1200 4 1000 0 1 2 3 4 5 6 7 8 9 (m3/min) 1200 (min-1) PWM duty cycle 100% PWM100% Fan speed 1200 Static pressure Static pressure 5 (inch H2O) (Pa) 48 VDC DC48 V 1400 PWM duty - Speed characteristics example Fan speed PWM duty cycle 6.50.3 3.50.3 380.5 Airflow direction DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side DC Fan 120 mm sq. 104.80.3 104.80.3 117 o1 30 4-o4.5 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1000G page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 181 DC Fan 120x120x38 mm San Ace 120 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 360 g Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 9GV1212P1J01 12 10.2 to 13.8 9GV1224P1J01** 9GV1224P1H01** 24 20.4 to 27.6 9GV1248P1J01 48 40.8 to 55.2 9GV1212P1G01 * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 100 100 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.0 0.19 2.1 0.19 1.5 0.8 0.75 0.06 36.0 2.28 25.2 2.28 36.0 19.2 36.0 2.88 6400 1500 5500 1500 6400 5200 6400 1500 6.35 1.49 5.45 1.49 6.35 5.16 6.35 1.49 224.0 52.6 192.6 52.6 224.0 182.3 224.0 52.6 360.0 19.8 265 19.8 360 237 360.0 26.1 [inchHO] 1.45 0.08 1.06 0.08 1.45 0.95 1.45 0.106 SPL Operating temperature Expected life [dB (A)] [C] [h] 64 33 60 33 64 58 64 33 -20 to +70 40000/60C ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 574 to 575. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch (inch H2O) H2O)(Pa) (Pa) (inch (inch H2O) H2O)(Pa) (Pa) 12 VDC DC12 DC12 V V 1.81.8 450450 1.81.8 450450 1.61.6 400400 1.41.4 350350 1.41.4 350350 Static pressure PWM duty cycle PWM PWM 100% 100% 1.21.2 300300 1.21.2 300300 1.01.0 250250 Static pressure 1.61.6 400400 0.80.8 200200 0.60.6 150150 00 /min) /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 (m 8 (m 3 (CFM) (CFM) 0 0 5050100100150150200200250250300300 Airflow 182 6000 1212 VV 5000 10.2 10.2 VV 0.80.8 200200 00 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6400 min-1 4000 3000 2000 1500 min-1 1000 0.20.2 5050 3 7000 13.8 13.8 VV 0.40.4 100100 0% 0% (min-1) PWM duty cycle 100% PWM100% PWM100% 0.60.6 150150 50% 50% 0.40.4 100100 0.20.2 5050 1.01.0 250250 PWM duty - Speed characteristics example Fan speed 9GV1212P1J01 3 3 /min) /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 (m 8 (m (CFM) (CFM) 0 0 5050100100150150200200250250300300 Airflow 0 100 (%) PWM duty cycle PWM Operating voltage range 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 PWM duty cycle PWM 100% 50% 0% 0 0 1 2 3 4 5 6 40 80 120 160 200 Airflow 9GV1224P1J01 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 PWM duty cycle PWM 100% 50% 1 2 40 80 120 160 200 9GV1224P1H01 3 4 5 6 Airflow (m3/min) 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 50% 1 2 3 40 80 120 160 200 4 Airflow 5 6 Static pressure 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 0.6 150 0.4 100 0.2 50 10.2 V 4000 3000 2000 1500 min-1 1000 2 4 3 6 5 1 0 40 80 120 160 200 240 (CFM) 100 (%) 0 7 (m3/min) 0 PWM duty cycle PWM Airflow 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% (min-1) 27.6 V 6000 24 V 5000 7000 20.4 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6400 min-1 4000 3000 2000 1000 1 2 3 4 5 6 7 100 (%) 0 (m3/min) PWM duty cycle PWM PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 1.4 350 1.2 300 1.0 250 27.6 V 0.8 200 24 V 0.6 150 0.4 100 0.2 50 0 0 6000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5200 min-1 5000 20.4 V 4000 3000 2000 1000 0 (CFM) 3 4 5 6 1 2 40 80 120 160 200 Airflow 100 (%) 0 (m3/min) PWM duty cycle PWM (CFM) With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 450 200 5500 min-1 Airflow (m3/min) PWM duty cycle 1.8 0.8 (inch H2O) (Pa) PWM duty cycle PWM 100% 9GV1248P1J01 5000 Operating voltage range 24 VDC DC24 V 0 12 V 0 40 80 120 160 200 240 (CFM) Static pressure Static pressure 350 250 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 1.2 1.0 (CFM) PWM duty cycle 1.4 6000 (inch H2O) (Pa) 24 VDC DC24 V 0 13.8 V Operating voltage range Static pressure Static pressure 1.4 300 7000 With pulse sensor with PWM control function (inch H2O) (Pa) 400 1.2 240 (CFM) PWM duty cycle 1.6 350 0 7 (m3/min) (min-1) PWM duty cycle 100% PWM100% 1.4 Fan speed 1.2 (inch H2O) (Pa) 12 VDC DC12 V Fan speed 350 Static pressure 1.4 (inch H2O) (Pa) 48 VDC DC48 V PWM PWM duty cycle 100% 50% 0% 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 300 (CFM) Airflow Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 7000 55.2 V 6000 48 V 5000 40.8 V (m3/min) 50 100 150 200 250 300 (CFM) 6400 min-1 4000 3000 2000 1000 1 2 3 4 5 6 7 8 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 0 1500 min-1 100 (%) PWM duty cycle PWM Airflow 183 DC Fan 120 mm sq. With pulse sensor with PWM control function Fan speed 9GV1212P1G01 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) (With ribs) 4-o4.50.3 Mounting hole 1200.8 104.80.3 Lead wire AWG24 UL 1430 300 +30 0 (10) 104.80.3 (5) (5) 1200.8 380.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 118 118 35 o1 118 27 o1 104.80.3 4-o4.5 104.80.3 104.80.3 Outlet side 4-o4.5 104.80.3 Inlet side 118 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 184 Resin finger guards Model no.: 109-1000G page: p. 539 DC DC Fan San Ace 120 9SG type DC Fan 120 mm sq. 120x120x38 mm Model 9SG1224H101 is not certified. General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 400 g Specifications The models listed below have pulse sensors. Model no. Rated voltage Operating voltage range Rated current Rated input 9SG1212G101 9SG1224G101 9SG1224H101 9SG1248G101 Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 4.0 2.0 0.46 1.0 48.0 48.0 11.0 48.0 6000 6000 3400 6000 7.35 7.35 4.02 7.35 260 260 142 260 340 340 126 340 SPL [inchHO] 1.37 1.37 0.51 1.37 Operating temperature Expected life [dB (A)] [C] [h] 64 64 48 64 -20 to +70 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 578. Lock sensor PWM control Airflow - Static Pressure Characteristics With pulse sensor (inch H2O) (Pa) 1.50 1.25 450 400 350 300 1.00 250 0.75 200 0.05 0.25 0 1.75 13.8 V 12 V 10.2 V 150 100 1.50 1.25 300 200 0.05 0 Airflow 350 0.75 0 50 100 150 200 250 300 (CFM) 400 250 0.25 1 2 3 4 5 6 7 8 9 (m3/min) 450 1.00 50 0 With pulse sensor (inch H2O) (Pa) Static pressure Static pressure 1.75 9SG1224G101 Operating voltage range 9SG1224H101 (inch H2O) (Pa) 27.6 V 24 V 20.4 V 150 100 0.7 180 160 0.6 140 0.5 120 0.3 0.2 0.1 0 0 1 2 3 4 5 6 7 8 9 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 27.6 V 24 V 20.4 V 0.4 100 50 0 With pulse sensor Operating voltage range Static pressure 9SG1212G101 Operating voltage range 80 60 40 20 0 1 2 3 4 5 (m3/min) 0 20 40 60 80 100120140160 180 (CFM) Airflow 185 Airflow - Static Pressure Characteristics 9SG1248G101 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 1.75 1.50 1.25 450 350 250 0.75 200 0.25 0 48 V 300 1.00 0.05 55.2 V 400 40.8 V 150 100 50 0 1 2 3 4 5 6 7 8 9 (m3/min) 0 50 100 150 200 250 300 (CFM) Airflow Dimensions (unit: mm) 8-o4.30.3 Mounting hole Lead wire AWG24 UL 1007 1200.8 104.80.3 AWG22 UL 1430 9SG1212G101 (Model no.: 9SG1212G101 only) +30 300 0 (10) 6.50.3 (3.5) 104.80.3 1200.8 380.5 6.50.3 (3.5) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 4-o4.5 118 o1 118 104.80.3 35 104.80.3 27 o1 118 104.80.3 4-o4.5 118 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 186 Resin finger guards Model no.: 109-1000G page: p. 539 DC DC Fan DC Fan 120 mm sq. 120x120x38 mm San Ace 120 9G type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 330 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9G1212G101 9G1212E101 9G1212H101 9G1212F101 9G1212M101 9G1224G101 9G1224E101 9G1224H101 9G1224F101 9G1224M101 9G1248G101 9G1248E101 9G1248H101 9G1248F101 9G1248M101 [V] 10.2 to 13.8 12 7 to 13.8 20.4 to 27.6 24 14 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.98 0.61 0.38 0.28 0.21 0.5 0.34 0.22 0.16 0.11 0.25 0.17 0.11 0.09 0.07 11.76 7.32 4.56 3.36 2.52 12 8.16 5.28 3.84 2.64 12 8.16 5.28 4.32 3.36 3600 3100 2600 2280 1950 3600 3100 2600 2280 1950 3600 3100 2600 2280 1950 3.88 3.34 2.8 2.45 2.1 3.88 3.34 2.8 2.45 2.1 3.88 3.34 2.8 2.45 2.1 137 118 99 87 74 137 118 99 87 74 137 118 99 87 74 135 100 70.4 54.2 39.6 135 100 70.4 54.2 39.6 135 100 70.4 54.2 39.6 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 49 46 39 36 32 49 46 39 36 32 49 46 39 36 32 -20 to +70 40000/60C 0.542 0.402 0.283 0.218 0.159 0.542 0.402 0.283 0.218 0.159 0.542 0.402 0.283 0.218 0.159 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 568 to 569. Lock sensor PWM control Airflow - Static Pressure Characteristics 9G1212E101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 180 140 Static pressure 0.6 0.5 140 100 0.3 80 0.1 0 13.8 V 12 V 120 0.4 0.2 0.5 160 Static pressure 0.7 10.2 V 60 40 20 0 1 0 2 50 3 100 9G1212H101 With pulse sensor 4 150 Airflow 5 6 (m3/min) 200 (CFM) 0.4 0.3 0.2 0.1 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.35 120 13.8 V 100 Static pressure 9G1212G101 12 V 80 10.2 V 60 40 20 0.30 1 0 2 50 3 100 4 150 Airflow 5 6 (m /min) 3 200 (CFM) 80 60 0.20 50 0.15 40 0.10 0 13.8 V 70 0.25 0.05 0 90 12 V 7V 30 20 10 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 187 Airflow - Static Pressure Characteristics 9G1212M101 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 90 70 60 0.20 50 0.15 40 0.10 0.05 0 13.8 V 70 12 V 7V 30 20 10 0 1 2 3 4 Airflow 9G1224E101 0.15 0.10 0.05 0 (m3/min) 0 20 40 60 80 100 120 140 0.20 0.7 60 50 12 V 40 7V 30 20 0 9G1224H101 Operating voltage range (inch H2O) (Pa) 140 90 0.3 0.2 0.1 0 27.6 V 100 Static pressure Static pressure 0.4 0.35 120 24 V 80 20.4 V 60 40 50 3 4 100 5 150 Airflow 6 (m3/min) 0.6 27.6 V 50 24 V 40 14 V 30 20 10 1 9G1248H101 20 2 40 60 Airflow 50 0.15 40 0.10 0.05 0 55.2 V 48 V 40.8 V 30 20 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 188 0.2 0.30 3 4 (m3/min) 50 0.15 40 0.10 0.10 0 55.2 V 48 V 40.8 V 1 2 50 3 100 4 5 24 V 14 V 30 20 10 0 150 Airflow 200 0.5 120 0.4 100 0.3 0.2 0.1 0 6 (m3/min) 1 2 3 4 (m3/min) With pulse sensor 55.2 V 48 V 80 40.8 V 60 40 20 0 1 0 (CFM) 9G1248M101 With pulse sensor 2 50 3 4 100 5 150 Airflow 6 (m3/min) 200 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 70 70 55.2 V 48 V 40.8 V 30 20 0.25 60 0.20 50 0.15 0.10 0.05 10 0 With pulse sensor 140 80 40 (CFM) Airflow 90 0.15 200 Airflow (inch H2O) (Pa) 0 50 150 6 (m3/min) 0 20 40 60 80 100 120 140 (CFM) 20 0.20 100 5 Operating voltage range 40 60 4 27.6 V 9G1248E101 60 0.25 0.05 10 0 2 With pulse sensor 140 80 0.35 Static pressure Static pressure 0.20 1 160 0.3 50 3 70 60 180 100 2 80 0.20 0 0.4 1 90 0.25 0 (inch H2O) (Pa) 70 0.30 0.05 Operating voltage range 80 60 14 V 0 90 0.25 24 V 9G1248F101 With pulse sensor (inch H2O) (Pa) 0.30 27.6 V 10 (CFM) Operating voltage range 0 Operating voltage range 20 120 0 3 (m3/min) 80 100 20 0 0.35 30 0.5 0.1 0 40 9G1224F101 With pulse sensor Operating voltage range 0.7 0 0.35 80 100 20.4 V 60 Airflow Static pressure Static pressure 0 60 (inch H2O) (Pa) 60 0.2 0 20 40 60 80 100 120 140 (CFM) 70 0.05 40 0.10 80 27.6 V 24 V (inch H2O) (Pa) 9G1248G101 With pulse sensor (inch H2O) (Pa) 0.10 0.15 200 (CFM) Operating voltage range 0.15 50 0 9G1224M101 0.20 60 0 2 40 Airflow 70 0.20 0.05 1 20 80 0.25 20 0 0.25 0.30 0.3 (CFM) Operating voltage range (inch H2O) (Pa) 0.5 100 0 3 (m3/min) 140 0.4 0 2 160 120 0.1 1 180 0.5 10 (CFM) With pulse sensor 0.6 13.8 V Static pressure 0.25 0.25 (inch H2O) (Pa) Static pressure Static pressure 0.30 80 Static pressure 0.35 With pulse sensor Operating voltage range Static pressure Operating voltage range 9G1224G101 With pulse sensor Static pressure 9G1212F101 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0 55.2 V 48 V 40 40.8 V 30 20 10 0 1 0 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) (With ribs) DC Dimensions (unit: mm) DC Fan 120 mm sq. 4-o4.30.3 Mounting hole 1190.8 104.80.3 (10) +30 300 0 Lead wire AWG24 UL 1007 104.80.3 1190.8 (5) (5) 380.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 117 104.80.3 o1 117 117 4-o4.5 34 104.80.3 26 o1 104.80.3 4-o4.5 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1000G page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 189 DC Fan 127x127x38 mm San Ace 127 9E type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 400 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109E1312A101 109E1312S101 109E1324G101 109E1324A101 109E1324S101 109E1348G101 109E1348A101 109E1348S101 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.4 1.2 1.1 0.7 0.53 0.54 0.36 0.28 16.8 14.4 26.4 16.8 12.7 25.9 17.3 13.4 3850 3450 4550 3850 3450 4550 3850 3450 4.81 4.37 5.66 4.81 4.37 5.66 4.81 4.37 170 154 200 170 154 200 170 154 155 125 216 155 125 216 155 125 [inchHO] SPL Operating temperature Expected life [dB (A)] 0.622 0.502 0.867 0.622 0.502 0.867 0.622 0.502 52 49 57 52 49 57 52 49 [C] [h] -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109E1312A101 109E1312S101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 100 0.3 80 0.1 0 12 V 120 0.4 0.2 13.8 V 140 10.2 V 60 40 20 0 1 0 190 2 50 3 100 4 150 Airflow 5 6 (m /min) 200 250 (CFM) 3 160 140 0.5 120 0.4 100 0.3 80 0.2 13.8 V Static pressure 0.5 160 0.6 Static pressure Static pressure 0.6 (inch H2O) (Pa) 0.7 180 12 V 10.2 V 60 40 0.1 20 0 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.8 0.7 109E1324G101 With pulse sensor 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 260 240 220 200 180 160 140 120 100 80 60 40 20 0 27.6 V 24 V 20.4 V 1 0 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 109E1324S101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 160 100 0.3 80 0.1 0 24 V 120 0.4 0.2 27.6 V 140 20.4 V 60 40 20 0 1 2 0 109E1348A101 50 3 100 4 5 150 Airflow 6 (m3/min) 200 250 (CFM) 0.2 20.4 V 60 40 0.1 20 0 0 55.2 V 140 48 V 120 80 0.6 Static pressure Static pressure 160 100 0 0.3 80 24 V 1 2 50 3 100 4 5 150 6 (m3/min) 200 Airflow (CFM) 55.2 V 48 V 40.8 V 1 0 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow With pulse sensor 0.7 0.3 0.1 100 0 180 0.4 0.2 0.4 27.6 V 260 240 220 200 180 160 140 120 100 80 60 40 20 0 (inch H2O) (Pa) 0.8 0.5 120 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Operating voltage range (inch H2O) (Pa) 0.6 140 0.5 109E1348S101 With pulse sensor Operating voltage range 0.7 160 Static pressure 0.5 0.6 Static pressure Static pressure 0.6 (inch H2O) (Pa) 0.7 180 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.8 0.7 109E1348G101 With pulse sensor DC Fan 127 mm sq. 109E1324A101 DC Airflow - Static Pressure Characteristics 40.8 V 60 40 20 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m /min) 200 250 (CFM) 3 160 140 0.5 120 0.4 100 0.3 80 0.2 55.2 V 48 V 40.8 V 60 40 0.1 20 0 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) Dimensions (unit: mm) 8-o4.30.3 Mounting hole (10) +30 300 0 1270.8 113.30.3 Lead wire AWG24 UL 1007 113.30.3 1270.8 Rotating direction 60.3 60.3 380.5 Airflow direction 191 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 113.30.3 Options Finger guards Model no.: 109-722, 109-722H, 109-723 page: p. 533 113.30.3 123 o1 123 192 4-o4.3 30 113.30.3 24 o1 113.30.3 4-o4.3 DC DC Fan DC Fan 127 mm sq. 127x127x38 mm San Ace 127 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 350 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P1312S101 109P1312H101 109P1324S101 109P1324H101 109P1348S101 109P1348H101 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.3 0.82 0.55 0.41 0.3 0.2 15.6 9.84 13.2 9.84 14.4 9.6 3300 2950 3300 2950 3300 2950 4.2 3.8 4.2 3.8 4.2 3.8 148 134 148 134 148 134 117.6 98 117.6 98 117.6 98 SPL [inchHO] 0.472 0.394 0.472 0.394 0.472 0.394 Operating temperature Expected life [dB (A)] [C] [h] 47 45 47 45 47 45 -20 to +60 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P1312S101 109P1312H101 With pulse sensor Operating voltage range Operating voltage range 13.8 V 0.4 12 V 100 10.2 V 0.3 0.2 0.4 Static pressure Static pressure 0.5 50 0.1 0 0 1 2 0 20 40 60 80 3 4 5 (m3/min) 100 120 140 160 180 (CFM) Airflow 0.3 0.2 0.1 0 (inch H2O) (Pa) 120 0.6 100 12 V 80 10.2 V 60 40 20 0 1 0 2 50 3 100 Airflow 150 27.6 V 0.5 13.8 V Static pressure 0.5 150 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.6 109P1324S101 With pulse sensor 4 150 5 (m3/min) 200 (CFM) 0.4 24 V 100 20.4 V 0.3 0.2 50 0.1 0 0 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 193 Airflow - Static Pressure Characteristics 109P1324H101 109P1348S101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.3 0.2 0.1 0 (inch H2O) (Pa) 100 27.6 V 80 24 V 40 20 0 1 0 2 50 3 100 Airflow 55.2 V 0.5 20.4 V 60 0.5 150 4 5 48 V 100 40.8 V 0.3 0.2 50 0.1 0 (m3/min) 150 Dimensions (unit: mm) 0.4 0.4 Static pressure Static pressure 0.4 0.6 0 1 2 3 4 5 (With ribs) 4-o4.30.3 Mounting hole (10) 1270.8 113.30.3 +30 300 0 Lead wire AWG24 UL 1007 (6) (6) 380.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 123 Options Finger guards Model no.: 109-722, 109-722H, 109-723 194 4-o4.3 .5 27 o1 123 113.30.3 24 o1 113.30.3 4-o4.3 page: p. 533 113.30.3 113.30.3 0.2 0.1 120 100 55.2 V 48 V 80 40.8 V 60 40 20 0 1 0 Airflow 113.30.3 1270.8 0.3 0 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) 200 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 120 Static pressure 0.5 109P1348H101 With pulse sensor 2 50 3 100 Airflow 4 150 5 (m3/min) 200 (CFM) DC DC Fan DC Fan 140 mm sq. 140x140x38 mm San Ace 140 9GV type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 630 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GV1412P1G001 9GV1412P1S001 12 10.8 to 13.2 24 21.6 to 26.4 48 36 to 60 9GV1412P1H001 9GV1424P1G001 9GV1424P1S001 9GV1424P1H001 9GV1448P1G001 9GV1448P1S001 9GV1448P1H001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 4.6 0.26 3.1 0.26 1.7 0.26 2.3 0.13 1.55 0.13 0.85 0.13 1.15 0.11 0.78 0.11 0.42 0.11 55.2 3.12 37.2 3.12 20.4 3.12 55.2 3.12 37.2 3.12 20.4 3.12 55.2 5.28 37.44 5.28 20.16 5.28 7600 2300 6650 2300 5200 2300 7600 2300 6650 2300 5200 2300 7600 2300 6650 2300 5200 2300 8.8 2.66 7.7 2.66 6.0 2.66 8.8 2.66 7.7 2.66 6.0 2.66 8.8 2.66 7.7 2.66 6.0 2.66 310 93 272 93 212 93 310 93 272 93 212 93 310 93 272 93 212 93 640 80 480 80 300 80 640 80 480 80 300 80 640 80 480 80 300 80 [inchHO] 2.57 0.32 1.93 0.32 1.2 0.32 2.57 0.32 1.93 0.32 1.2 0.32 2.57 0.32 1.93 0.32 1.2 0.32 SPL Operating temperature Expected life [dB (A)] [C] [h] 70 39 67 39 62 39 70 39 67 39 62 39 70 39 67 39 62 39 -20 to +70 40000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) Static pressure 2.5 600 2.0 500 1.5 400 1.0 0.5 0 (inch H2O) (Pa) 12 VDC DC12 V 700 3.5 PWM PWM duty cycle 100% 300 200 100 0 20% 1 2 3 4 5 6 7 8 9 (m3/min) 800 700 2.5 600 2.0 500 1.5 400 1.0 0.5 0 40 80 120 160 200 240 280 320 (CFM) Airflow 3.0 900 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 13.2 V 7000 12 V 10.8 V 300 4000 3000 2000 100 1000 1 2 3 4 5 6 7 8 9 7600 min-1 5000 200 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed PWM duty cycle Static pressure 9GV1412P1G001 (m3/min) 0 40 80 120 160 200 240 280 320 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 195 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GV1412P1S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0 300 200 20% 100 0 2.0 1.5 1.0 0.5 1 2 3 4 5 6 7 8 9 0 (m3/min) 0 40 80 120 160 200 240 280 320 (CFM) 0.50 0.25 0 PWM PWM duty cycle 250 200 150 20% 50 0 1 0 2 3 4 5 6 7 Static pressure 1.5 400 1.0 0.5 0 0.25 100 3.5 3.0 20% 4000 3000 1000 1 2 3 4 5 6 7 (m3/min) 0 100 (%) PWM duty cycle PWM 40 80 120 160 200 240 (CFM) Airflow 500 1.5 400 1.0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 5000 4000 3000 200 2000 100 1000 1 2 3 4 5 6 7 8 9 7600 min-1 6000 300 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow PWM PWM duty cycle 2.5 100% 300 200 20% 1 2 3 4 5 6 7 8 9 Airflow 2.0 1.5 1.0 0.5 (m3/min) 0 40 80 120 160 200 240 280 320 (CFM) 196 5200 min-1 5000 2000 21.6 V 700 400 0 10.8 V 0 40 80 120 160 200 240 280 320 (CFM) Static pressure Static pressure 0 6000 24 V 700 (inch H2O) (Pa) 24 VDC DC24 V 600 100 7000 Operating voltage range (inch H2O) (Pa) 0.5 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 1.0 8000 26.4 V 800 2.0 0 (m3/min) 900 600 Airflow 1.5 0 2.5 0.5 1 2 3 4 5 6 7 8 9 500 (min-1) PWM duty cycle 100% PWM100% 300 0.50 0 40 80 120 160 200 240 280 320 (CFM) 2.0 100 (%) PWM duty cycle PWM PWM duty - Speed characteristics example 12 V (inch H2O) (Pa) 200 9GV1424P1S001 0 (m3/min) 13.2 V 0 24 VDC DC24 V 300 0 1 2 3 4 5 6 7 8 9 Operating voltage range PWM PWM duty cycle 100% 100 3000 With pulse sensor with PWM control function 700 500 4000 1000 400 200 Airflow (inch H2O) (Pa) 2.0 0.75 0 (m3/min) PWM duty cycle 600 1.00 40 80 120 160 200 240 (CFM) 9GV1424P1G001 2.5 0 5000 2000 100 1.25 100% 100 200 500 Static pressure 0.75 300 (inch H2O) (Pa) Static pressure Static pressure 1.00 400 6650 min-1 Airflow 12 VDC DC12 V 300 6000 10.8 V Operating voltage range (inch H2O) (Pa) 1.25 12 V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 350 7000 0 40 80 120 160 200 240 280 320 (CFM) Airflow 9GV1412P1H001 500 13.2 V Fan speed 0.5 400 600 Fan speed 1.0 2.5 100% 8000 0 600 500 400 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 26.4 V 7000 24 V 6000 Fan speed 1.5 PWM PWM duty cycle 500 (min-1) PWM duty cycle 100% PWM100% 700 Static pressure Static pressure 2.0 (inch H2O) (Pa) 12 VDC DC12 V 600 PWM duty - Speed characteristics example Fan speed PWM duty cycle 21.6 V 300 200 6650 min-1 5000 4000 3000 2000 100 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 1000 1 2 3 4 5 6 7 8 9 (m3/min) 0 40 80 120 160 200 240 280 320 (CFM) Airflow 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0 150 100 20% 50 0 1 0 2 3 4 5 6 7 Static pressure 1.5 400 1.0 0.5 0 0 1 3.5 200 3.0 20% 2.5 1.5 400 1.0 400 300 200 20% 1 2 3 4 5 6 7 8 9 0.25 0 600 2.0 500 1.5 1.0 0.5 8000 36 V 200 20% 2 5000 4000 3000 2000 100 0 6650 min-1 6000 400 300 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 48 V 1000 1 2 3 4 5 6 7 8 9 0 (m3/min) 100 (%) PWM duty cycle PWM 3 4 5 6 7 (m3/min) 40 80 120 160 200 240 (CFM) Airflow 1.00 0.50 0.25 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6000 300 36 V 200 5000 5200 min-1 4000 3000 2000 100 0 8000 7000 48 V 0 (min-1) 60 V 400 0.75 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 500 150 1 (min-1) 60 V 1.25 100% 200 0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% (inch H2O) (Pa) 250 0 100 (%) PWM duty cycle PWM Airflow PWM PWM duty cycle 50 0 (m3/min) Operating voltage range 48 VDC DC48 V 100 1 2 3 4 5 6 7 8 9 0 40 80 120 160 200 240 280 320 (CFM) Static pressure Static pressure 0.50 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.75 4000 1000 2.5 0 (m3/min) PWM duty cycle 1.00 5000 2000 Airflow 300 7600 min-1 6000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 200 0 40 80 120 160 200 240 280 320 (CFM) 1.25 8000 300 700 100% 350 (min-1) 36 V (inch H2O) (Pa) 48 VDC DC48 V 9GV1448P1H001 100 (%) PWM duty - Speed characteristics example Airflow PWM PWM duty cycle 0 0 PWM duty cycle PWM 0 40 80 120 160 200 240 280 320 (CFM) Static pressure Static pressure 0 7 (m3/min) Operating voltage range 600 100 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.5 6 48 V 600 500 0 (m3/min) PWM duty cycle 1.0 5 60 V 700 Airflow 1.5 4 PWM duty cycle 100% PWM100% 800 2.0 0.5 1 2 3 4 5 6 7 8 9 500 3 Airflow 900 0 40 80 120 160 200 240 280 320 (CFM) 2.0 2 40 80 120 160 200 240 (CFM) (inch H2O) (Pa) 300 9GV1448P1S001 4000 1000 Operating voltage range PWM PWM duty cycle 100% 0 5200 min-1 5000 2000 0 48 VDC DC48 V 100 21.6 V With pulse sensor with PWM control function 700 500 100 Airflow (inch H2O) (Pa) 2.0 0.25 (m3/min) PWM duty cycle 600 300 200 0 6000 24 V 0.50 40 80 120 160 200 240 (CFM) 9GV1448P1G001 2.5 0.75 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 Fan speed 0.25 200 1.00 26.4 V 400 Fan speed 0.50 250 8000 Fan speed 0.75 1.25 100% Static pressure 1.00 PWM PWM duty cycle 300 (min-1) PWM duty cycle 100% PWM100% 500 Static pressure Static pressure 1.25 (inch H2O) (Pa) 24 VDC DC24 V 350 PWM duty - Speed characteristics example Fan speed PWM duty cycle 1000 1 2 3 4 5 6 7 (m3/min) 40 80 120 160 200 240 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 197 DC Fan 140 mm sq. 9GV1424P1H001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Dimensions (unit: mm) 8-o4.50.3 Mounting hole 300 +30 0 Lead wire Rated voltage V fan 12 V 12 124.50.5 1400.8 (10) AWG20 UL 3266 Rated voltage 24 V/48 V fan 24 V/48 V AWG22 UL 3266 124.50.5 40.2 40.2 60.4 60.4 380.5 1400.8 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 124.50.3 124.50.3 4-o4.5 50 o1 138 138 Options Model no.: 109-719, 109-719H 198 124.50.3 138 138 124.50.3 47 o1 Finger guards 4-o4.5 page: p. 533 DC DC Fan DC Fan 140 mm sq. 140x140x38 mm San Ace 140 9P type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 450 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109P1412H101 109P1412M101 109P1424H101 109P1424M101 109P1448H101 109P1448M101 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.73 0.33 0.37 0.16 0.2 0.09 8.76 3.96 8.88 3.84 9.6 4.32 2600 1900 2600 1900 2600 1900 4.5 3.3 4.5 3.3 4.5 3.3 159 117 159 117 159 117 94 52 94 52 94 52 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 46 38 46 38 46 38 -20 to +70 40000/60C 0.378 0.209 0.378 0.209 0.378 0.209 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 564. Lock sensor Airflow - Static Pressure Characteristics 109P1412M101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 150 0.4 100 0.5 0.4 100 13.8 V 12 V 0.3 0.2 Static pressure Static pressure 0.6 10.2 V 50 0.1 0 0 1 0 2 50 3 100 109P1424H101 With pulse sensor 4 150 Airflow 5 6 (m3/min) 200 (CFM) (inch H2O) (Pa) 0.6 0.3 13.8 V 12 V 0.2 50 10.2 V 0.1 0 With pulse sensor Operating voltage range Static pressure 109P1412H101 150 0.5 0.4 100 27.6 V 24 V 0.3 0.2 20.4 V 50 0.1 0 1 0 2 50 3 100 Airflow 4 150 5 (m3/min) 200 (CFM) 0 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 199 Airflow - Static Pressure Characteristics 109P1448H101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 150 0.4 100 Static pressure Static pressure 0.6 27.6 V 24 V 0.2 50 20.4 V 0.1 0 0.5 0.4 100 55.2 V 48 V 0.3 0.2 40.8 V 50 0.1 0 1 0 2 50 3 4 100 Airflow 150 5 0 (m3/min) 0 200 (CFM) 1 0 2 50 3 100 4 150 Airflow 5 0.3 0.1 380.5 124.50.5 1400.8 +30 300 0 Lead wire AWG24 UL 1007 (5) (5) Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 50 138 138 Options Finger guards Model no.: 109-719, 109-719H 200 4-o4.5 o1 138 138 124.50.3 46 o1 124.50.3 4-o4.5 page: p. 533 124.50.3 124.50.3 0 1 0 200 (CFM) (10) 124.50.5 1400.8 50 40.8 V 0 6 (m3/min) 55.2 V 48 V 0.2 Dimensions (unit: mm) 4-o4.30.3 Mounting hole With pulse sensor Operating voltage range (inch H2O) (Pa) 0.4 100 0.3 109P1448M101 With pulse sensor Static pressure 109P1424M101 2 50 3 100 Airflow 4 150 5 (m3/min) 200 (CFM) DC DC Fan DC Fan 150 mm sq. 150x150x50 mm San Ace 150 9GV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 450 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9GV1512H501 9GV1512M501 9GV1524M501 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.9 1.2 0.6 34.8 14.4 14.4 3900 3000 3000 8.54 6.35 6.35 300 224 224 210 132 132 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 61 53 53 -20 to +70 40000/60C 0.84 0.53 0.53 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 575. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9GV1512H501 9GV1512M501 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 12 V 10.2 V 2 4 6 8 10 (m3/min) 0 50 100 150 200 250 300 350 (CFM) Airflow 175 0.6 150 0.5 125 0.4 100 0.3 75 0.2 50 0.1 25 0 0 (inch H2O) (Pa) 0.7 175 0.6 150 13.8 V Static pressure 1.0 13.8 V 0.7 With pulse sensor Operating voltage range (inch H2O) (Pa) 300 Static pressure Static pressure 1.2 9GV1524M501 With pulse sensor 12 V 10.2 V 2 0 4 6 50 100 150 200 250 Airflow 8 (m3/min) 300 (CFM) 27.6 V 0.5 125 24 V 0.4 100 0.3 75 0.2 50 0.1 25 0 0 20.4 V 2 0 4 6 8 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 201 Dimensions (unit: mm) (With ribs) 4-o4.50.3 Mounting hole (10) 1500.8 1350.5 +30 300 0 Lead wire AWG22 UL 1430 (6.5) 1350.5 1500.8 (6.5) 500.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 4-o4.5 4-o4.5 78 62 o1 1480.5 1350.3 1480.5 1350.3 o1 1350.3 1480.5 1350.3 1480.5 Options Finger guards Model no.: 109-1051, 109-1052 202 page: p. 533 DC DC Fan o San Ace 172 9E type DC Fan o172 mm 172x147x25 mm Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 500 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109E4712M401 109E4712L401 109E4724H401 109E4724F401 109E4724M401 109E4724L401 109E4748S401 109E4748H401 109E4748F401 109E4748M401 109E4748L401 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.3 1.0 1.0 0.79 0.58 0.44 0.62 0.52 0.4 0.32 0.25 15.6 12.0 24.0 19.0 13.9 10.6 29.8 25.0 19.2 15.4 12.0 2800 2500 3400 3100 2800 2500 3650 3400 3100 2800 2500 5.2 4.6 6.4 5.8 5.2 4.6 6.8 6.4 5.8 5.2 4.6 183 162 226 204 183 162 240 226 204 183 162 92 73 135 112 92 73 156 135 112 92 73 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 51 48 57 54 51 48 58 57 54 51 48 -20 to +60 40000/60C 0.369 0.293 0.542 0.45 0.369 0.293 0.627 0.542 0.45 0.369 0.293 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on pp. 561 to 562. PWM control Airflow - Static Pressure Characteristics 109E4712M401 109E4712L401 With pulse sensor Operating voltage range Operating voltage range 0.30 0.25 0.20 0.15 0.10 0.05 0 0.35 13.8 V 12 V 10.2 V 0.30 0.25 0.20 0.15 0.10 0.05 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 0 (inch H2O) (Pa) 200 100 90 80 70 60 50 40 30 20 10 0 0.7 13.8 V Static pressure 0.35 0.40 Static pressure Static pressure 0.40 120 110 100 90 80 70 60 50 40 30 20 10 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.45 109E4724H401 With pulse sensor 12 V 10.2 V 0.6 27.6 V 150 24 V 0.5 0.4 100 20.4 V 0.3 0.2 50 0.1 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 0 0 1 2 3 4 5 6 7 8 0 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 203 Airflow - Static Pressure Characteristics 109E4724M401 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 150 120 110 100 90 80 70 60 50 40 30 20 10 0 Static pressure 0.5 0.4 0.40 24 V 100 20.4 V 0.3 0.2 0.45 27.6 V Static pressure 0.6 50 0.1 0 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 1 0 2 50 109E4748S401 3 4 5 6 7 0 (m3/min) 100 150 200 250 (CFM) (inch H2O) (Pa) 200 200 150 48 V 40.8 V 0.5 0.4 100 0.3 0.2 50 0.1 0 0 1 2 3 4 5 6 7 8 0.20 0.15 0.10 0.05 0 2 50 3 4 100 5 150 Airflow 0.35 55.2 V 48 V 40.8 V 0.30 0.25 0.20 0.15 0.10 0.05 1 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 0 0.10 24 V 20.4 V 1 0 2 50 109E4748F401 With pulse sensor 3 4 100 5 150 Airflow 6 (m3/min) 200 (CFM) With pulse sensor Operating voltage range 0.6 48 V 100 40.8 V 50 0 1 2 3 4 5 6 7 8 100 90 80 70 60 50 40 30 20 10 0 (m3/min) 50 100 150 200 250 300 (CFM) Airflow With pulse sensor 55.2 V 48 V 40.8 V 1 0 2 50 3 100 4 150 Airflow 150 55.2 V 0.5 55.2 V Operating voltage range 0.40 0.15 27.6 V (inch H2O) (Pa) 109E4748L401 With pulse sensor 0.20 100 90 80 70 60 50 40 30 20 10 0 200 (CFM) 0.3 0.2 0.25 0 6 (m3/min) (inch H2O) (Pa) 120 110 100 90 80 70 60 50 40 30 20 10 0 0 204 1 0 Static pressure Static pressure 0.25 0.4 0.30 0.05 150 Airflow (inch H2O) (Pa) 0.30 20.4 V 0.5 0 (m3/min) Operating voltage range 0.35 0.6 50 100 150 200 250 300 (CFM) 109E4748M401 0.40 24 V 0.1 0 0.45 27.6 V 0.7 55.2 V Static pressure Static pressure 0.6 0.35 Operating voltage range (inch H2O) (Pa) 0.7 0.40 109E4748H401 With pulse sensor Operating voltage range 0.8 (inch H2O) (Pa) 0 Airflow With pulse sensor Operating voltage range Static pressure Operating voltage range 109E4724L401 With pulse sensor Static pressure 109E4724F401 5 6 (m3/min) 200 (CFM) 0.4 48 V 100 40.8 V 0.3 0.2 50 0.1 0 0 1 0 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow DC Dimensions (unit: mm) 8-o4.50.4 Mounting hole DC Fan o172 mm +50 300 0 o1720.8 o1620.5 (10) Lead wire AWG24 UL 1007 55 55 7.50.4 7.50.4 25.40.5 1470.8 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 8.5 4- R4 .2 5 1620.5 o1 68 4-o4.5 55 147 55 Options Finger guards page: p. 534 Model no.: 109-319E, 109-319H, 109-320 205 DC Fan o 172x150x51 mm San Ace 172 9HV type Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 800 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9HV5724P5H001 16 to 30 48 9HV5748P5G001 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 20 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 5.0 0.5 5.0 0.41 120 12.0 240 19.7 8000 3000 10500 3700 12.3 4.6 16.1 5.6 434 162 568 198 1000 175 1600 250 [inchHO] 4.02 0.7 6.43 1.01 SPL Operating temperature Expected life [dB (A)] [C] [h] 77 51 83 57 -20 to +70 40000/60C 70000/40C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 575. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9HV5724P5H001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 900 4.0 100% 3.0 2.0 1.0 0 600 50% 300 0 0 206 1200 Static pressure Static pressure 4.0 (inch H2O) (Pa) 24 VDC DC24 V 1200 20% 4 8 12 100 200 300 400 500 Airflow 16 (m3/min) (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 10000 30 V 24 V 8000 900 Fan speed PWM duty cycle 3.0 2.0 1.0 0 600 16 V 300 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8000 min-1 6000 4000 2000 4 8 12 0 100 200 300 400 500 Airflow 16 (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 7.0 PWM duty cycle PWM Static pressure 100% 6.0 1500 Static pressure (inch H2O) (Pa) 48 VDC DC48 V 7.0 1800 5.0 1200 4.0 3.0 2.0 1.0 0 900 600 50% 20% 300 0 6.0 1500 4.0 3.0 2.0 8 12 16 20 12000 72 V 48 V 10000 36 V 900 600 0 0 100 200 300 400 500 600 700 (CFM) 4 8 12 16 20 (m3/min) 0 100 200 300 400 500 600 700 (CFM) Airflow Airflow Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 10500 min-1 8000 6000 4000 2000 300 0 (m3/min) (min-1) PWM duty cycle 100% PWM100% 5.0 1200 1.0 4 1800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 8-o4.50.3 Mounting hole +30 30 0 0 1620.5 o1720.8 10 Lead wire AWG18 UL 1430 55.5 55.5 7.50.4 7.50.4 510.8 1500.8 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 8.5 4- R4 .2 5 1620.5 o1 68 4-o4.5 55 5 .5 147 55. Options Finger guards page: p. 534 Model no.: 109-319J, 109-319E, 109-319H, 109-320 207 DC Fan o172 mm 9HV5748P5G001 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example DC Fan o 172x150x51 mm San Ace 172 9SG type Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 760 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9SG5724P5H61 [V] 24 20.4 to 27.6 48 36 to 72 9SG5748P5G01 9SG5748P5H01 PWM duty cycle* [%] 100 0 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.8 0.18 2.91 0.21 1.62 0.21 67.2 4.32 140 10.1 78 10.1 6500 1300 8600 2000 6500 2000 11.6 2.32 15.46 3.59 11.6 3.59 410 81.9 546 127 410 127 540 30 1000 75.1 770 75.1 [inchHO] 2.16 0.12 4.02 0.3 3.09 0.3 SPL Operating temperature Expected life [dB (A)] [C] [h] 71 28 78 40 71 40 -20 to +70 40000/60C -20 to +60 * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 578. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9SG5724P5H61 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 600 2.0 500 1.5 400 1.0 0.5 0 PWM duty cycle PWM 100% 50% 300 200 100 0% 0 2 0 208 4 6 8 10 12 14 (m3/min) 100 200 300 400 500 (CFM) Airflow 2.5 600 2.0 500 1.5 1.0 (min-1) PWM duty cycle 100% PWM100% 700 Static pressure Static pressure 2.5 (inch H2O) (Pa) DC24 V 24 VDC 700 PWM duty - Speed characteristics example 7000 24 V 400 20.4 V 300 200 0.5 100 0 0 2 4 6 8 10 12 14 (m3/min) 100 200 300 400 500 (CFM) Airflow 6500 min-1 5000 4000 3000 2000 1000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 27.6 V Fan speed PWM duty cycle 0 1300 min-1 100 (%) PWM duty cycle PWM With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 5.0 DC48 V 48 VDC 1200 4.0 1000 PWM duty cycle PWM 100% 800 600 2.0 400 1.0 200 0 50% 4.0 5 10 15 20 0 900 700 PWM PWM duty cycle 100% 600 2.0 500 400 0 50% 20 3000 2000 min-1 100 (%) 0 (m3/min) PWM PWM duty cycle PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% (min-1) 600 2.0 500 400 300 1.0 200 10 0 15 (m3/min) 100 200 300 400 500 Airflow 0 0 (CFM) 7000 6000 6500 min-1 5000 4000 3000 2000 2000 min-1 1000 100 5 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 48 V/72 V 36 V 700 0% 0 0 4000 9000 800 3.0 Static pressure Static pressure (inch H2O) (Pa) 800 100 15 Operating voltage range 900 200 10 Airflow 48 VDC DC48 V 300 5000 With pulse sensor with PWM control function (inch H2O) (Pa) 1.0 5 0 100 200 300 400 500 600 700 (CFM) PWM duty cycle 3.0 6000 1000 0 Airflow 8600 min-1 7000 2000 200 0 100 200 300 400 500 600 700 (CFM) 9SG5748P5H01 36 V 400 1.0 (m3/min) 48 V 600 2.0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 72 V 800 3.0 (min-1) 9000 1000 0% 0 PWM duty cycle 100% PWM100% 1200 Fan speed 3.0 Static pressure Static pressure 5.0 PWM duty - Speed characteristics example Fan speed PWM duty cycle 5 10 15 (m3/min) 100 200 300 400 500 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 8-o4.50.3 hole Mounting +30 300 0 1620.5 o1720.8 10 Lead wire AWG22 UL 1430 .5 55. 55 5 7.50.4 7.50.4 510.8 1500.8 Rotating direction Airflow direction 209 DC Fan o172 mm 9SG5748P5G01 DC Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 8.5 4R 4. 25 1620.5 o1 68 4-o4.5 55 5 .5 147 55. Options Finger guards page: p. 534 Model no.: 109-319J, 109-319E, 109-319H, 109-320 210 DC DC Fan o San Ace 172 9GV type DC Fan o172 mm 172x150x51 mm Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 800 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9GV5724H501 9GV5748H501 Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 24 48 20.4 to 27.6 40.8 to 55.2 4.0 2.0 96 96 6300 6300 11.32 11.32 400 400 690 690 [inchHO] 2.77 2.77 SPL Operating temperature Expected life [dB (A)] [C] [h] 74 74 -20 to +70 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor PWM control Airflow - Static Pressure Characteristics 9GV5724H501 9GV5748H501 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 3.5 3.5 800 2.5 600 2.0 500 1.5 400 1.0 3.0 700 27.6 V 24 V 20.4 V Static pressure Static pressure 3.0 With pulse sensor 300 200 800 700 2.5 600 2.0 500 1.5 400 1.0 300 200 0.5 100 0.5 100 0 0 0 0 2 0 100 4 6 200 8 300 Airflow 10 12 400 (m3/min) 500 (CFM) 55.2 V 48 V 40.8 V 2 0 100 4 6 200 8 300 Airflow 10 12 400 (m3/min) 500 (CFM) 211 Dimensions (unit: mm) 8-o4.50.3 hole Mounting 10 o1720.8 1620.5 +30 300 0 Lead wire AWG22 UL 1430 .5 55. 55 5 7.50.4 7.50.4 510.8 1500.8 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 8.5 4- R4 .2 5 1620.5 o1 68 4-o4.5 .5 55 .5 147 55 Options Finger guards page: p. 534 Model no.: 109-319J, 109-319E, 109-319H, 109-320 212 DC DC Fan o San Ace 172 9E type DC Fan o172 mm 172x150x51 mm Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 760 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109E5712K501 109E5712Y501 109E5712H501 109E5712F501 109E5712M501 109E5724C501 109E5724K501 109E5724H501 109E5724F501 109E5724M501 109E5748C501 109E5748K501 109E5748H501 109E5748F501 109E5748M501 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.9 2.3 1.2 0.68 0.48 2.3 1.3 0.58 0.35 0.2 1.2 0.7 0.28 0.19 0.11 34.8 27.6 14.4 8.16 5.76 55.2 31.2 13.92 8.4 4.8 57.6 33.6 13.44 9.12 5.28 4100 3800 3050 2500 2000 4800 4100 3050 2500 2000 4800 4100 3050 2500 2000 8.5 8 6.4 5.1 4.2 9.9 8.5 6.4 5.1 4.2 9.9 8.5 6.4 5.1 4.2 300 282 226 180 148 350 300 226 180 148 350 300 226 180 148 243.0 210 137.2 95 67.6 308.0 243.0 137.2 95 67.6 308.0 243.0 137.2 95 67.6 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.976 0.84 0.551 0.38 0.271 1.237 0.976 0.551 0.38 0.271 1.237 0.976 0.551 0.38 0.271 60 60 52 47 41 66 60 52 47 41 66 60 52 47 41 [C] [h] -20 to +60 -20 to +70 -20 to +70 40000/60C -20 to +60 -20 to +70 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 562. Lock sensor PWM control Airflow - Static Pressure Characteristics 109E5712K501 109E5712Y501 With pulse sensor Operating voltage range Operating voltage range 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (inch H2O) (Pa) 13.8 V 12 V 10.2 V 2 0 4 100 6 200 Airflow 8 300 10 (m3/min) 400 (CFM) 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.8 200 0.6 150 0.4 100 0.2 50 0 0 13.8 V 13.8 V Static pressure 300 Static pressure Static pressure (inch H2O) (Pa) 1.2 109E5712H501 With pulse sensor 12 V 10.2 V 2 0 0 4 100 6 200 Airflow 8 300 10 (m3/min) 400 (CFM) 12 V 10.2 V 1 2 3 4 5 6 7 8 0 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 213 Airflow - Static Pressure Characteristics 109E5712F501 109E5712M501 With pulse sensor Operating voltage range 109E5724C501 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.6 150 90 1.6 400 80 1.4 350 70 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 10 0.2 50 0 0 0 0.30 0.4 100 Static pressure 12 V 10.2 V 0.3 50 0.15 40 0.05 0 0 0 1 2 3 4 5 6 7 (m3/min) 0.4 100 0.2 50 0 0 0.8 24 V 20.4 V 2 4 100 6 8 200 Airflow 10 300 (m3/min) 0.05 0 150 0.4 100 0.2 50 0 0 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 70 Static pressure 400 27.6 V 60 24 V 20.4 V 30 20 10 0 1 0 2 50 109E5748H501 3 100 4 150 Airflow 5 6 (m3/min) 200 20.4 V 1 2 3 4 5 6 7 8 (inch H2O) (Pa) 200 0.6 150 150 0.4 100 0.2 50 0 48 V 40.8 V 0 1 2 3 4 5 6 7 8 0 214 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 20.4 V 0.2 50 0.1 0 1 2 50 0 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) 55.2 V 48 V 40.8 V 2 4 100 6 8 200 10 12 (m3/min) 300 400 Airflow 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 55.2 V 48 V 40.8 V 2 0 (CFM) 4 100 6 8 200 Airflow 109E5748M501 With pulse sensor 10 300 (m3/min) 400 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.35 55.2 V 0.30 48 V 40.8 V 0.3 50 0.1 0 27.6 V 109E5748K501 With pulse sensor 0.4 100 0.2 (CFM) 24 V Airflow 0.5 Static pressure Static pressure 0.6 400 0.3 0 (m3/min) Operating voltage range 55.2 V 10 12 (m3/min) 300 With pulse sensor 0.4 100 50 100 150 200 250 300 (CFM) 0 (inch H2O) (Pa) 0.8 8 Airflow 0.5 24 V 109E5748F501 With pulse sensor 6 200 0.6 150 (CFM) Operating voltage range 4 100 Operating voltage range (inch H2O) (Pa) 1.4 2 109E5724F501 Operating voltage range 1.6 24 V 20.4 V (inch H2O) (Pa) 0 80 40 0.10 0.6 90 50 Airflow 27.6 V 0 (CFM) With pulse sensor 109E5748C501 With pulse sensor (inch H2O) (Pa) 0.15 200 200 400 (CFM) Operating voltage range 0.20 150 6 (m3/min) 27.6 V 27.6 V 109E5724M501 0.25 100 5 (inch H2O) (Pa) 0 0.30 4 Static pressure 0.6 150 50 3 Static pressure 200 2 Operating voltage range Static pressure 0.8 0.35 0 300 250 1 109E5724H501 With pulse sensor (inch H2O) (Pa) 1.0 10.2 V 20 Airflow Operating voltage range 1.2 12 V 30 100 150 200 250 (CFM) 50 109E5724K501 Static pressure 50 0.1 0 Static pressure 0.20 0.10 13.8 V 60 Static pressure 0.2 0.25 (inch H2O) (Pa) Static pressure 0.5 Static pressure 0.35 13.8 V With pulse sensor 0.25 1 0 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 80 70 50 0.15 40 0.10 0 55.2 V 60 0.20 0.05 0 90 48 V 40.8 V 30 20 10 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) DC Dimensions (unit: mm) DC Fan o172 mm 4-o4.50.3 Mounting hole 10 o1720.8 1620.5 +30 30 0 0 Lead wire AWG24 UL 1007 or AWG22 UL 1430 1500.8 Rotating direction 7.50.4 7.50.4 510.8 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 2- R4 .25 1620.3 o1 68 148 8.5 2-o4.5 Options Finger guards page: p. 534 Model no.: 109-319E, 109-319H, 109-320 215 DC Fan o 172x51 mm San Ace 172 9E type Round type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 780 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109E1712K501 109E1712Y501 109E1712H501 109E1712F501 109E1712M501 109E1724C501 109E1724K501 109E1724H501 109E1724F501 109E1724M501 109E1748C501 109E1748K501 109E1748H501 109E1748F501 109E1748M501 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow [A] [W] [min-1] [m/min] 2.9 2.3 1.2 0.68 0.48 2.3 1.3 0.58 0.35 0.2 1.2 0.7 0.28 0.19 0.11 34.8 27.6 14.4 10.8 5.76 55.2 31.2 13.92 8.4 4.8 57.6 33.6 13.44 9.12 5.28 4100 3800 3050 2500 2000 4800 4100 3050 2500 2000 4800 4100 3050 2500 2000 8.5 7.8 6.4 5.1 4.2 9.9 8.5 6.4 5.1 4.2 9.9 8.5 6.4 5.1 4.2 [CFM] 300 276 226 180 148 350 300 226 180 148 350 300 226 180 148 Max. static pressure [Pa] 243.0 210.0 137.2 95.0 67.6 308.0 243.0 137.2 95 67.6 308.0 243.0 137.2 95 67.6 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.976 0.843 0.551 0.382 0.271 1.237 0.976 0.551 0.382 0.271 1.237 0.976 0.551 0.382 0.271 55 53 47 42 36 60 55 47 42 36 60 55 47 42 36 [C] [h] -20 to +60 -20 to +70 40000/60C -20 to +60 -20 to +70 -20 to +60 -20 to +70 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 561. Lock sensor PWM control Airflow - Static Pressure Characteristics 109E1712Y501 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 1.2 300 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 13.8 V 12 V 10.2 V 0 216 Static pressure Static pressure (inch H2O) (Pa) 2 4 100 6 200 Airflow 109E1712H501 With pulse sensor 8 300 10 (m3/min) 400 (CFM) (inch H2O) (Pa) 13.8 V 0.8 200 12 V 0.6 150 10.2 V 0.4 100 50 0 0 0.8 200 0.6 150 0.4 100 0.2 50 0 0 13.8 V 1.0 250 0.2 With pulse sensor Operating voltage range Static pressure 109E1712K501 2 4 6 8 10 (m3/min) 0 50 100 150 200 250 300 350 (CFM) Airflow 12 V 10.2 V 1 2 3 4 5 6 7 8 0 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 109E1712M501 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 13.8 V 0.4 100 0.30 Static pressure 12 V 10.2 V 0.3 50 0.1 1 2 109E1724K501 4 5 6 7 0.2 50 0 0 24 V 20.4 V 2 4 100 6 8 200 Airflow 10 300 (m3/min) 0 0.6 0.4 100 0.2 50 0 0 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 70 27.6 V 60 24 V 20.4 V 30 20 10 0 1 2 50 109E1748H501 3 100 4 150 Airflow 5 6 (m3/min) 200 Static pressure Static pressure 50 0 1 2 3 4 5 6 7 8 0 (m /min) 3 50 100 150 200 250 300 (CFM) Airflow 400 (CFM) 20.4 V 0.2 50 0.1 0 1 2 50 0 109E1748K501 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) 55.2 V 48 V 40.8 V 2 4 100 6 8 200 10 12 (m3/min) 300 400 Airflow 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 55.2 V 48 V 40.8 V 2 0 (CFM) 4 100 6 8 200 Airflow 109E1748M501 With pulse sensor 10 300 (m3/min) 400 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.35 55.2 V 0.30 48 V 40.8 V 0.3 50 0.1 0 300 Airflow 24 V 0.3 0 (m3/min) With pulse sensor 0.4 100 0.2 0.4 100 Airflow 0.5 40.8 V 100 200 10 12 (m3/min) 27.6 V 50 100 150 200 250 300 (CFM) 109E1748F501 48 V 8 With pulse sensor 0.5 Operating voltage range 0.6 150 150 6 Operating voltage range 1 2 3 4 5 6 7 8 0 55.2 V 4 100 109E1724F501 20.4 V (CFM) With pulse sensor 2 0 (CFM) 24 V (inch H2O) (Pa) 0 200 Airflow 24 V 20.4 V 0.6 150 200 0.2 150 6 (m3/min) 27.6 V (inch H2O) (Pa) (inch H2O) (Pa) 0.4 100 5 Operating voltage range Operating voltage range 0.6 4 (inch H2O) (Pa) 0 0.8 3 With pulse sensor 109E1748C501 With pulse sensor 80 0.15 50 0 400 40 2 150 1.6 50 1 200 400 (CFM) Static pressure Static pressure 0 90 0.20 0 50 0 27.6 V (inch H2O) (Pa) 0.05 10 Operating voltage range Operating voltage range 0.10 100 0.2 20 0 27.6 V 109E1724M501 0.25 0 0.8 0 0.30 150 0.4 30 Static pressure 100 0.35 0.10 10.2 V (inch H2O) (Pa) 200 0.4 200 0.6 12 V 109E1724H501 With pulse sensor 250 150 0.8 40 300 0.6 250 0.15 Static pressure Static pressure 0.8 1.0 Airflow (inch H2O) (Pa) 1.0 300 13.8 V 60 50 (m3/min) Operating voltage range 1.2 1.2 100 150 200 250 (CFM) 50 0 3 350 70 0.20 0.05 0 400 1.4 Static pressure 0 0.25 1.6 80 Static pressure Static pressure 0.5 (inch H2O) (Pa) 90 Static pressure 0.35 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.6 150 0.2 109E1724C501 With pulse sensor DC Fan o172 mm 109E1712F501 DC Airflow - Static Pressure Characteristics 0.25 1 0 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 80 70 50 0.15 40 0.10 0 55.2 V 60 0.20 0.05 0 90 48 V 40.8 V 30 20 10 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 217 Dimensions (unit: mm) 8-o4.50.3 Mounting hole +30 30 0 0 o1720.8 1620.5 (10) Lead wire AWG24 UL 1007 or AWG22 UL 1430 1620.5 Rotating direction 7.50.4 7.50.4 510.8 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4- R4 .2 5 1620.3 o1 68 1620.3 8.5 4-o4.5 Options Finger guards page: p. 534 Model no.: 109-1066, 109-1068, 109-319E, 109-319H, 109-320 218 DC DC Fan o DC Fan o200 mm 200x70 mm San Ace 200 9GV type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 1800 g Power on when current is shut off. Do not power on 15 s or more after power off. Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 48 9GV2048P0G201** * PWM frequency: 1 kHz [V] 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 12.5 Max. airflow [min-1] [W] 600 [m/min] 8000 31.5 [CFM] 1112 Max. static pressure [Pa] 1400 [inchHO] 5.62 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 81 Expected life ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GV2048P0G201 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0 1600 PWM duty cycle PWM 100% Static pressure Static pressure 6.0 5.5 1400 5.0 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 (inch H2O) (Pa) 48 VDC DC48 V 1600 50% 20% 10 20 400 800 Airflow 30 1,200 40 (m /min) 3 (CFM) 6.0 5.5 1400 5.0 1200 4.5 4.0 1000 3.5 3.0 800 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 9000 8000 48 V Voltage: 48 VDC DC48 V PWM frequency: PWM1 kHz1 kHz 8000 min-1 7000 72 V Fan speed PWM duty cycle 36 V 6000 5000 4000 3000 2000 1000 10 20 400 800 Airflow 30 1,200 40 (m /min) 3 (CFM) 0 100 (%) PWM duty cycle PWM 219 Dimensions (unit: mm) 00 0 .5 4-o4.50.2 Depth 1010 4-o4.30.15 o2 (10) 188.40.5 2201 2080.5 33030 .5 0 00 o2 Lead wire AWG14 UL 1015 188.40.5 2080.5 2201 Rotating direction 120.4 120.4 700.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side o2080.3 o2080.3 4-o 4.5 o1 94 Options Finger guards Model no.: 109-1102, 109-1103 220 page: p. 535 4-o4.30.15 DC DC Fan o San Ace 200 9EC type DC Fan o200 mm 200x70 mm Model 9EC2048J001 is not certified. General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 1800 g Power on when current is shut off. Do not power on 10 s or more after power off. Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9EC2024H001 9EC2048J001 9EC2048A001 9EC2048H001 Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 26.4 40.8 to 55.2 43.0 to 51.0 40.8 to 52.8 2.0 4.4 2.2 1.2 48.0 211.2 105.6 57.6 3600 6100 4800 3600 11.0 18.3 14.7 11.0 388 646 519 388 360 1000 640 360 48 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 60 75 68 60 -20 to +60 40000/60C 1.446 4.016 2.57 1.446 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 567. Lock sensor PWM control Airflow - Static Pressure Characteristics 9EC2048J001 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 1.5 4.5 4.0 26.4 V 400 24 V 300 20.4 V 1.0 200 0.5 100 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 0 2 0 100 4 6 200 8 10 12 300 Airflow 400 (m3/min) 500 (CFM) 0 1100 1000 900 800 700 600 500 400 300 200 100 0 9EC2048A001 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 500 Static pressure Static pressure 2.0 With pulse sensor 55.2 V 48 V 40.8 V 2 4 6 8 10 12 14 16 18 20 (m3/min) 0 100 200 300 400 500 600 700 (CFM) Airflow 3.0 Static pressure 9EC2024H001 800 2.5 600 2.0 500 1.5 400 1.0 51 V 48 V 700 43 V 300 200 0.5 100 0 0 2 4 6 8 10 12 14 16 0 (m3/min) 100 200 300 400 500 600 (CFM) Airflow 221 Airflow - Static Pressure Characteristics 9EC2048H001 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 2.0 1.5 500 52.8 V 400 48 V 300 40.8 V 1.0 200 0.5 0 100 0 2 0 4 100 6 200 8 10 12 300 Airflow 400 (m3/min) 500 (CFM) Dimensions (unit: mm) o2 00 -1 0 8-o4.30.15 Mounting hole flat head screw 8-o4.50.3 Mounting hole 33020 2201 2080.5 188.4 (10) Lead wire AWG22 UL 1007 0 -1 130.4 00 o2 120.4 188.4 2080.5 2201 0 70 -1 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 208 188.4 208 R5 4- 4-o4.5 4-o4.5 o1 188.4 2 8-R 94 Options Finger guards page: p. 535 Model no.: 109-720, 109-720H, 109-721, 109-721H 222 Counter Rotating Fan Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 9CRA 04 12 K 4 01 Type name Frame size Voltage Speed code Frame thickness Sensor specifications Fans with PWM control function 9CRA 03 12 P 4 K Type name Frame size Voltage PWM control function Frame thickness Speed code Type name 03 Individual customer s spec (2 to 3 digits) 9CR 9CRA 9CRB 9CRD 9CRE 9CRH 9CRV Frame size (mm) 03 04 06 08 12 57 o 172 x 150 38 x 38 40 x 40 60 x 60 80 x 80 120 x 120 (sidecut) Voltage (V) 12 12 Speed code G H Frame thickness (mm) 0 76 Sensor specifications 48 48 J K 4 48 S etc. 5 51, 56 6 56 8 80 9 102 01 02 D01 With a pulse sensor Without a sensor With a lock sensor How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 223 Counter Rotating Fan DC Counter rotating fans feature high airflow and high static pressure. Related product: Long Life Fan pp. 373, 375, 381 Counter Rotating Fan 38x38x48 mm San Ace 38 9CRA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 80 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CRA0312P4K03 12 10.8 to 13.2 9CRA0312P4J03 PWM duty cycle* [%] Rated current Rated input 100 0 100 0 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 1.5 0.2 1.1 0.18 18.0 2.4 13.2 2.2 17600 14520 5280 4200 16000 13200 4800 3960 0.77 0.22 0.7 0.21 27.2 7.8 24.7 7.4 700.0 54.9 560.0 50.4 2.81 0.22 2.25 0.2 64 33 62 31 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 567. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch (inch H2O) H2O) (Pa) (Pa) 2.52.5 600 600 500 2.02.0 500 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 00 3.03.0 PWM duty cycle PWM PWM 100% 100% 50% 50% 0% 0% 0 0 0.10.1 3 3 /min) /min) (m(m 0.20.2 0.30.3 0.40.4 0.50.5 0.60.6 0.70.7 0.80.8 0.90.9 (CFM) 0 0 5 5 10101515202025253030(CFM) Airflow 224 (inch (inch H2O) H2O) (Pa) (Pa) 800 800 700 700 2.52.5 600 600 500 2.02.0 500 700 700 12 VDC DC12 DC12 V V Static pressure Static pressure 3.03.0 800 800 PWM duty - Speed characteristics example 20000 13.2 13.2 VV 10.8 10.8 VV DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 17600 min-1 Inlet 1212 VV 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 00 (min-1) PWM duty cycle 100% PWM100% PWM100% 15000 Fan speed 9CRA0312P4K03 PWM duty cycle 5280 min-1 10000 14520 min-1 Outlet 5000 4200 min-1 0 0 0.10.1 3 3 /min) /min) (m(m 0.20.2 0.30.3 0.40.4 0.50.5 0.60.6 0.70.7 0.80.8 0.90.9 (CFM) 0 0 5 5 10101515202025253030(CFM) Airflow 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0312P4J03 Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 12 VDC DC12 DC12 V V 700 700 500 2.02.0 500 400 1.51.5 400 1.01.0 0.50.5 00 1.51.5 1.01.0 200 200 0% 0% 100 100 1212 VV 500 2.02.0 500 50% 50% 300 300 20000 10.8 10.8 VV 400 400 300 300 200 200 00 0 0 5 5 1010 1515 2020 2525 Airflow 0 0 0.10.10.20.20.30.30.40.40.50.50.60.60.70.70.80.8 3 3 /min) /min) (m(m 0 0 5 5 1010 1515 2020 2525 (CFM) (CFM) 10000 Airflow (CFM) (CFM) 16000 min-1 Inlet 15000 5000 0.50.5 100 100 0 0 0.10.10.20.20.30.30.40.40.50.50.60.60.70.70.80.8 3 3 /min) /min) (m(m DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 13.2 13.2 VV 2.52.5 600 600 PWM duty cycle PWM PWM 100% 100% Static pressure Static pressure 600 600 (min-1) PWM duty cycle 100% PWM100% PWM100% 700 700 Fan speed (inch H2O) (Pa) (inch H2O) (Pa) 2.52.5 PWM duty - Speed characteristics example 4800 min-1 13200 min-1 Outlet 3960 min-1 100 (%) 0 PWM duty cycle PWM Dimensions (unit: mm) Outlet side +30 320 0 4-o3.50.3 Mounting hole 480.5 (10) (5) 380.5 (5) 300.3 300.3 (10) 4-o3.50.3 Mounting hole +30 320 0 380.5 Inlet side Lead wire AWG28 UL 1007 Rotating direction Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 37 37 4-o3.7 300.3 37 .5 (16) (16) 300.3 Options Finger guards page: p. 532 Model no.: 109-1065 225 Counter Rotating Fan 38 mm sq. PWM duty cycle DC With pulse sensor with PWM control function Counter Rotating Fan 40x40x48 mm San Ace 40 9CRA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 80 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CRA0412P4K03 12 9CRA0412P4J03 10.8 to 13.2 9CRA0412P4G03 PWM duty cycle* [%] Rated current Rated input 100 0 100 0 100 0 Rated speed [min-1] Inlet Outlet [A] [W] 1.6 0.19 1.2 0.15 1.0 0.15 19.2 2.28 14.4 1.8 12.0 1.8 Max. airflow [m/min] 17500 11700 0.92 5250 3510 0.276 16200 10800 0.85 4500 3000 0.236 14700 9800 0.77 4410 2940 0.231 [CFM] Max. static pressure [Pa] 32.5 650.0 9.75 58.5 30.0 560.0 8.33 43.2 27.2 460.0 8.16 41.4 SPL Operating temperature Expected life [inchHO] [dB (A)] [C] [h] 2.61 0.235 2.25 0.173 1.85 0.166 64 33 62 28 59 28 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 567. Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 2.52.5 600 600 3.03.0 100% 100% 2.02.0 500 500 2.02.0 500 500 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 00 50% 50% 0% 0% 3 3 /min) (m(m /min) 0 00.10.1 0.20.2 0.30.3 0.40.4 0.50.5 0.60.6 0.70.7 0.80.8 0.90.9 1.01.0 (CFM) (CFM) 0 0 5 5 101015152020252530303535 Airflow 226 800 800 700 700 2.52.5 600 600 PWM duty cycle PWM PWM 700 700 (inch H2O) (Pa) (inch H2O) (Pa) Static pressure Static pressure 3.03.0 12 VDC DC12 V V DC12 800 800 PWM duty - Speed characteristics example 20000 1212V V 10.8 10.8V V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 17500 min-1 Inlet 13.2 13.2V V 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 00 (min-1) PWM duty cycle 100% PWM100% PWM100% 15000 Fan speed 9CRA0412P4K03 5250 min-1 10000 11700 min-1 Outlet 5000 3510 min-1 3 3 /min) (m(m /min) 0 00.10.1 0.20.2 0.30.3 0.40.4 0.50.5 0.60.6 0.70.7 0.80.8 0.90.9 1.01.0 0 0 5 5 101015152020252530303535(CFM) (CFM) Airflow 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Operating voltage range (inch H2O)(Pa) (Pa) (inch H2O) 3.03.0 PWM duty cycle PWM PWM 100% 100% 500 2.02.0 500 500 2.02.0 500 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 50% 50% 0% 0% 00 3 3 /min) /min) 0 00.10.10.20.20.30.30.40.40.50.50.60.60.70.70.80.80.90.91.01.0(m(m 005 (inch H2H O)2O)(Pa) (inch (Pa) 3.03.0 700 700 800 800 700 700 2.52.5 600 600 PWM duty cycle PWM PWM 100% 100% Static pressure Static pressure 4500 min-1 10800 min-1 10000 Outlet 5000 3000 min-1 100 (%) 0 PWM duty cycle PWM Airflow 12 VDC DC12 VV DC12 2.52.5 600 600 00 1212V V 10.8V V 10.8 Operating voltage range 800 800 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 16200 min-1 15000 With pulse sensor with PWM control function (inch H2H O)2O)(Pa) (inch (Pa) 2.02.0 500 500 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz Inlet 13.2V V 13.2 3 3 /min) /min) 0 00.10.10.20.20.30.30.40.40.50.50.60.60.70.70.80.80.90.91.01.0(m(m Airflow PWM duty cycle 3.03.0 20000 (CFM) 0 0 5 5 101015152020252530303535(CFM) (CFM) 5 101015152020252530303535(CFM) 9CRA0412P4G03 (min-1) PWM duty cycle 100% PWM100% PWM100% 2.02.0 500 500 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 50% 50% 0% 0% 00 3 3 /min) 0 00.10.10.20.20.30.30.40.40.50.50.60.60.70.70.80.80.90.91.01.0(m(m /min) (CFM) 0 0 5 5 101015152020252530303535(CFM) Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 20000 13.2 13.2V V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 Inlet 15000 Fan speed 400 1.51.5 400 300 300 1.01.0 200 200 0.50.5 100 100 00 700 700 2.52.5 600 600 700 700 2.52.5 600 600 800 800 Static pressure Static pressure 3.03.0 (inch H2O)(Pa) (Pa) (inch H2O) 12 VDC DC12 DC12 VV 800 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle DC With pulse sensor with PWM control function Counter Rotating Fan 40 mm sq. 9CRA0412P4J03 1212V V 10.8 10.8V V 14700 min-1 4410 min -1 10000 9800 min-1 Outlet 5000 2940 min-1 3 3 /min) 0 00.10.10.20.20.30.30.40.40.50.50.60.60.70.70.80.80.90.91.01.0(m(m /min) 0 0 5 5 101015152020252530303535(CFM) (CFM) 100 (%) 0 PWM duty cycle PWM Airflow Dimensions (unit: mm) Inlet side 4-o3.50.3 Mounting hole Outlet side +30 320 0 400.5 480.5 (10) (5) (5) 320.3 Lead wire AWG28 UL 1007 4-o3.50.3 Mounting hole +30 320 0 Rotating direction Airflow direction 400.5 320.3 (10) Rotating direction 227 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards Model no.: 109-059, 109-059H 228 page: p. 532 Counter Rotating Fan San Ace 40 9CRH type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 110 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRH0412P5J001 [V] [V] 12 10.8 to 12.6 PWM duty cycle* [%] Rated current Rated input 100 20 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 2.52 0.06 30.24 0.72 29500 25500 3000 2600 0.93 0.08 32.9 2.8 1700 17 6.83 0.07 70 20 -20 to +70 30000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRH0412P5J001 With pulse sensor with PWM control function Operating voltage range 12 VDC DC12 V 8.0 2000 PWM PWM duty cycle 7.0 1800 100% 1600 6.0 1400 5.0 1200 4.0 1000 3.0 800 60% 600 2.0 400 1.0 200 20% 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 Airflow (CFM) (inch H2O) (Pa) (min-1) PWM duty cycle 100% PWM100% 8.0 2000 12 V/12.6 V 7.0 1800 1600 6.0 10.8 V 1400 5.0 1200 4.0 1000 3.0 800 600 2.0 400 1.0 200 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 PWM duty - Speed characteristics example 5 10 15 20 25 30 35 30000 25000 Fan speed Static pressure (inch H2O) (Pa) Static pressure PWM duty cycle Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 29500 min-1 25500 min-1 20000 15000 10000 5000 (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM Airflow 229 Counter Rotating Fan 40 mm sq. DC 40x40x56 mm Dimensions (unit: mm) Inlet side Outlet side +30 320 0 4-o3.50.3 Mounting hole 560.5 (10) (5) 400.3 320.3 (5) +30 0 320.3 320 Lead wire AWG 24 UL 1061 Airflow direction Rotating direction 4-o3.50.3 Mounting hole Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (17.6) 40 320.3 4-o3.7 (17.6) Options Finger guards Model no.: 109-059, 109-059H 230 page: p. 532 Rotating direction 400.3 (10) Counter Rotating Fan San Ace 40 9CRV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 100 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRV0412P5J201 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 0 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 1.8 0.11 21.6 1.32 22500 20000 3800 3500 0.9 0.14 31.8 4.9 1050 30 4.22 0.12 68 26 -20 to +70 40000/60C * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Static pressure (inch H2O) (Pa) 12 VDC DC12 V 4.5 1100 PWM PWM duty cycle 4.0 1000 100% 900 3.5 800 3.0 700 2.5 600 2.0 500 50% 1.5 400 300 1.0 200 0% 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 Airflow (CFM) (inch H2O) (Pa) Static pressure PWM duty cycle PWM duty - Speed characteristics example 0 (min-1) PWM duty cycle 100% PWM100% 4.5 1100 12 V/13.2 V 4.0 1000 900 10.8 V 3.5 800 3.0 700 2.5 600 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 5 10 15 20 25 30 35 (CFM) 25000 20000 Fan speed 9CRV0412P5J201 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 22500 min-1 22000 min-1 Inlet 15000 10000 3800 min-1 Outlet 5000 3500 min-1 0 100 (%) PWM duty cycle PWM Airflow 231 Counter Rotating Fan 40 mm sq. DC 40x40x56 mm Dimensions (unit: mm) Inlet side Outlet side +30 320 0 4-o3.50.3 Mounting hole 560.5 (10) (5) 400.3 320.3 (5) +30 320 0 Lead wire AWG 28 UL 1061 Airflow direction Rotating direction 4-o3.50.3 Mounting hole Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (17.6) 40 320.3 4-o3.7 (17.6) Options Finger guards Model no.: 109-059, 109-059H 232 page: p. 532 Rotating direction 400.3 320.3 (10) Counter Rotating Fan San Ace 40 9CRD type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 90 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CRD0412P5J03 9CRD0412P5G03 12 10.8 to 13.2 9CRD0412P5H03 9CRD0412P5M03 PWM duty cycle* [%] Rated current Rated input 100 0 100 0 100 0 100 0 Rated speed [min-1] Inlet Outlet [A] [W] 1.15 0.12 0.9 0.1 0.6 0.09 0.52 0.07 13.8 1.44 10.8 1.2 7.2 1.08 6.24 0.84 19000 3700 16700 3350 15000 3000 14000 2000 SPL Operating temperature Expected life [m/min] Max. airflow [CFM] [Pa] [inchHO] [dB (A)] [C] [h] 0.87 0.15 0.77 0.13 0.7 0.12 0.65 0.07 30.72 5.3 27.19 4.59 24.72 4.24 22.95 2.47 630 25 500 21 410 16 360 7 2.53 0.1 2.01 0.08 1.65 0.06 1.45 0.03 61 22 58 21 56 20 54 15 -20 to +70 40000/60C 12600 2500 11250 2250 10000 2000 9300 1300 Max. static pressure * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 12 VDC DC12 V 700 3.0 600 PWM PWM duty cycle 100% 2.0 500 1.5 400 1.0 0.5 0 50% 300 200 100 0% 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 (CFM) Airflow Static pressure Static pressure 2.5 (inch H2O) (Pa) 800 700 2.5 600 20000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 Inlet 13.2 V 12 V 1.5 400 300 1.0 200 0.5 100 10.8 V 19000 min-1 15000 12600 min-1 3700 min-1 10000 Outlet 5000 2500 min-1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 (min-1) PWM duty cycle 100% PWM100% 2.0 500 0 PWM duty - Speed characteristics example Fan speed 9CRD0412P5J03 PWM duty cycle 5 10 15 20 25 30 35 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 233 Counter Rotating Fan 40 mm sq. DC 40x40x56 mm Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRD0412P5G03 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 3.0 600 PWM duty cycle PWM 100% 2.0 500 1.5 400 0 200 100 0% Airflow 12 VDC DC12 V 700 1.5 400 0.5 0 100 50% 0% 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 (CFM) 9CRD0412P5M03 12 VDC DC12 V 700 0 300 50% 2.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 (CFM) 800 (min-1) PWM duty cycle 100% PWM100% 20000 13.2 V 12 V 10.8 V 15000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15000 min-1 Inlet 10000 min-1 10000 3000 min-1 Outlet 5000 2000 min-1 0 100 (%) duty cycle PWMPWM 5 10 15 20 25 30 35 (CFM) Airflow 600 1.5 400 1.0 0 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 20000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 700 2.0 500 0.5 0% Airflow 234 (inch H2O) (Pa) Static pressure Static pressure PWM PWM duty cycle 100% 1.5 400 100 100 (%) 0 PWM duty cycle PWM 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 3.0 600 2.0 500 0.5 Outlet PWM duty - Speed characteristics example Operating voltage range (inch H2O) (Pa) 200 11250 min-1 10000 With pulse sensor with PWM control function PWM duty cycle 1.0 800 700 2.5 600 Airflow 2.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 (CFM) (inch H2O) (Pa) Static pressure Static pressure PWM PWM duty cycle 100% 200 3350 min-1 5000 Airflow 3.0 600 2.0 500 1.0 16700 min-1 Inlet 2250 min-1 Operating voltage range (inch H2O) (Pa) 300 10.8 V 15000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 2.5 12 V 1.5 400 300 1.0 200 0.5 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 5 10 15 20 25 30 35 (CFM) 9CRD0412P5H03 13.2 V 2.0 500 0 20000 Fan speed 0.5 50% 300 (min-1) PWM duty cycle 100% PWM100% 300 200 13.2 V 12 V 10.8 V Fan speed 1.0 800 700 2.5 600 Static pressure Static pressure 2.5 (inch H2O) (Pa) DC12 V 12 VDC 700 PWM duty - Speed characteristics example Fan speed PWM duty cycle 15000 10000 Outlet 1300 min-1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 9300 min-1 2000 min-1 5000 100 14000 min-1 Inlet 5 10 15 20 25 30 35 (CFM) Airflow 0 100 (%) duty cycle PWMPWM Dimensions (unit: mm) +30 320 0 4-o3.50.3 Mounting hole 560.5 (10) (5) (5) 400.3 320.3 4-o3.50.3 Mounting hole Lead wire AWG28 UL 1007 Airflow direction Rotating direction 400.3 +30 320 0 320.3 (10) Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (17.6) 40 320.3 4-o3.7 (17.6) Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 235 DC Outlet side Counter Rotating Fan 40 mm sq. Inlet side Counter Rotating Fan 40x40x56 mm San Ace 40 9CRE type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 110 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRE0412P5J03 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 0 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 1.4 0.1 16.8 1.2 15800 12200 2850 2250 0.9 0.12 31.8 4.2 570.0 13.7 2.29 0.055 62 20.5 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 500 2.02.0 500 300 1.21.2 300 50% 50% 200 0.80.8 200 100 0.40.4 100 00 00 600 2.42.4 600 Static pressure Static pressure 500 2.02.0 500 400 1.61.6 400 700 2.82.8 700 PWM duty cycle PWM PWM 100% 100% 600 2.42.4 600 20000 13.2 13.2V V 1212V V 10.8 10.8V V 400 1.61.6 400 300 1.21.2 300 15000 (CFM) (CFM) 00 00 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 Inlet -1 10000 2850 min 15800 min-1 12200 min-1 Outlet 5000 100 0.40.4 100 3 3 /min) (m(m /min) 0.1 0.10.2 0.20.3 0.30.4 0.40.5 0.50.6 0.60.7 0.70.8 0.80.9 0.91.0 1.0 Airflow (min-1) PWM duty cycle 100% PWM100% PWM100% 200 0.80.8 200 0% 0% 0 0 5 5 101015152020252530303535 236 (Pa) (Pa) (inch H2O) (inch H2O) 12 VDC DC12 V V DC12 700 2.82.8 700 PWM duty - Speed characteristics example Fan speed 9CRE0412P5J03 2250 min-1 3 3 (m(m /min) /min) 0.1 0.10.2 0.20.3 0.30.4 0.40.5 0.50.6 0.60.7 0.70.8 0.80.9 0.91.0 1.0 (CFM) 0 0 5 5 101015152020252530303535 (CFM) Airflow 0 100 (%) PWM duty cycle PWM Outlet side +30 320 0 4-o3.50.3 Mounting hole 560.5 (10) 50.3 50.3 400.3 320.3 4-o3.50.3 Mounting hole (10) 320.3 400.3 +30 320 0 Lead wire AWG28 UL 1061 Airflow direction Rotating direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 237 Counter Rotating Fan 40 mm sq. Inlet side DC Dimensions (unit: mm) Counter Rotating Fan 60x60x51 mm San Ace 60 9CR type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 180 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CR0612P5G03 12 10.8 to 13.2 9CR0612P5H03 PWM duty cycle* [%] Rated current Rated input 100 0 100 0 Rated speed [min-1] Inlet Outlet [A] [W] 2.7 0.22 2.0 0.22 32.4 2.64 24.0 2.64 11500 3000 10500 3000 9000 2300 8200 2300 Max. airflow [m/min] [CFM] 2.03 0.48 1.85 0.48 71.7 16.9 65.4 16.9 Max. static pressure [Pa] 600 40 500 40 SPL Operating temperature Expected life [inchHO] [dB (A)] [C] [h] 2.41 0.16 2.01 0.16 68 34 65 34 -20 to +70 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Pulse sensor Differs according to the model. Refer to the table on p. 567. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 12 VDC DC12 V V DC12 Static pressure 700 700 2.52.5 600 600 PWM duty cycle PWM PWM 100% 100% 2.02.0 500 500 1.51.5 1.01.0 400 400 300 300 00 0% 0% 3 3 /min) 0.50.5 1.01.0 1.51.5 2.02.0 2.52.5(m(m /min) (CFM) (CFM) 0 0101020203030404050506060707080809090 Airflow 238 700 700 2.52.5 600 600 2.02.0 500 500 1.51.5 1.01.0 200 200 0.50.5 100 100 00 50% 50% (inch H2O) (Pa) (inch H2O) (Pa) 400 400 PWM duty - Speed characteristics example Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 1212 VV 10.8 VV 10.8 300 300 00 15000 13.2 VV 13.2 200 200 0.50.5 100 100 00 (min-1) PWM100% PWM duty cycle 100% PWM100% Inlet Fan speed (inch H2O) (Pa) (inch H2O) (Pa) PWM duty cycle Static pressure 9CR0612P5G03 11500 min-1 10000 9000 min-1 3000 min-1 Outlet 5000 2300 min-1 3 3 /min) 0.50.5 1.01.0 1.51.5 2.02.0 2.52.5(m(m /min) (CFM) (CFM) 0 0101020203030404050506060707080809090 Airflow 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CR0612P5H03 Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.50.5 00 300300 50% 50% 200200 00 10.8 VV 10.8 300300 (CFM) 0 0 1010202030304040505060607070(CFM) 10500 min-1 8200 min-1 3000 min-1 Outlet 5000 2300 min-1 3 3 (m(m /min) 0.50.5 1.01.0 1.51.5 2.02.0 /min) (CFM) 0 0 1010202030304040505060607070(CFM) Airflow Inlet 10000 100100 00 00 3 3 (m(m /min) /min) 0.50.5 1.01.0 1.51.5 2.02.0 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 1212 VV 200200 0.50.5 0% 0% 100100 1.01.0 15000 13.2 VV 13.2 1.51.5 400400 1.01.0 400400 (min-1) PWM100% PWM duty cycle 100% PWM100% 600600 2.02.0 500500 Static pressure Static pressure PWM duty cycle PWM PWM 100% 100% 2.02.0 500500 1.51.5 2.52.5 12 VDC DC12 V V DC12 600600 Fan speed (inch H2O) (Pa) (inch H2O) (Pa) 2.52.5 PWM duty - Speed characteristics example Airflow 100 (%) 0 PWM duty cycle PWM Dimensions (unit: mm) Inlet side Outlet side +50 300 0 4-o4.30.3 Mounting hole 510.5 (4) (10) 600.5 500.3 (4) 4-o4.30.3 Mounting hole +50 300 0 600.5 500.3 (10) Lead wire AWG26 AWG26 UL 1430 UL 1430 Airflow direction Rotating direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 59 500.3 4- o4.5 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 239 Counter Rotating Fan 60 mm sq. PWM duty cycle DC With pulse sensor with PWM control function Counter Rotating Fan 60x60x56 mm San Ace 60 9CRA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 200 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CRA0612P6K001 12 9CRA0612P6J001 10.8 to 13.2 9CRA0612P6G001 PWM duty cycle* [%] Rated current Rated input 100 0 100 0 100 0 [A] [W] 3.1 0.17 2.3 0.15 1.3 0.1 37.2 2.0 27.6 1.8 15.6 1.2 Rated speed Max. airflow [min-1] Inlet Outlet 18300 3800 16800 3800 13500 3000 15800 3300 14500 3300 11400 2500 SPL Operating temperature Expected life [m/min] [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 2.28 0.47 2.1 0.47 1.65 0.36 80.5 16.6 74.2 16.6 58.3 12.7 1130 49 950 49 620 31 4.54 0.2 3.82 0.2 2.49 0.12 73 35 70 35 65 29 30000/60C -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0612P6K001 With pulse sensor with PWM control function Operating voltage range 5.5 1400 5.0 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 PWM duty cycle PWM 100% 50% 0% 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow 240 (inch H2O) (Pa) 12 VDC DC12 V Static pressure Static pressure (inch H2O) (Pa) (CFM) 5.5 1400 5.0 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 13.2 V 12 V Fan speed PWM duty cycle 10.8 V 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 20000 18000 Inlet 16000 14000 3800 min-1 12000 10000 8000 6000 4000 3300 min-1 2000 0 18300 min-1 15800 min-1 Outlet 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0612P6J001 PWM PWM duty cycle 100% 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 800 600 50% 400 200 0 0% 0.5 1.0 1.5 2.0 Airflow 9CRA0612P6G001 Static pressure 2.5 1.5 1.0 0.5 0 PWM duty cycle PWM 100% 600 0 50% 0% 0.5 0 12000 10000 1.0 1.5 2.0 2.5 (m3/min) Airflow Outlet 6000 2000 0.5 14500 min-1 3800 min-1 8000 4000 200 0 10 20 30 40 50 60 70 80 4.5 800 200 400 (inch H2O) (Pa) 12 VDC DC12 V 1200 400 10.8 V 600 0 Inlet 14000 3300 min-1 0 100 (%) PWM PWM duty cycle (CFM) Operating voltage range 4.0 1000 2.0 2.0 1.5 1.0 0.5 16800 min-1 16000 12 V 800 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 3.0 3.0 2.5 (CFM) PWM duty cycle 3.5 3.5 18000 13.2 V 4.0 1000 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 4.5 4.5 (min-1) PWM duty cycle 100% PWM100% 1200 1.0 1.5 2.0 Airflow (min-1) PWM duty cycle 100% PWM100% 1200 18000 3.5 3.0 2.5 2.0 1.5 1.0 0.5 14000 800 13.2 V 12 V 600 10.8 V 400 0 0 13500 min-1 Inlet 12000 10000 8000 11400 min-1 3000 min-1 Outlet 6000 4000 200 2000 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16000 4.0 1000 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 PWM duty - Speed characteristics example Fan speed Static pressure 4.0 1000 Static pressure 4.5 (inch H2O) (Pa) 12 VDCV DC12 1200 Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Airflow 2500 min-1 100 (%) 0 PWM PWM duty cycle (CFM) Dimensions (unit: mm) Inlet side 500.3 600.5 4-o4.50.3 Mounting hole Outlet side +50 300 0 (10) Lead wire AWG26 AWG26 UL 1430 UL 1430 500.3 600.5 Rotating direction (4) (4) 560.5 Airflow direction 4-o4.50.3 Mounting hole Rotating direction 241 Counter Rotating Fan 60 mm sq. Operating voltage range Fan speed PWM duty cycle DC With pulse sensor with PWM control function Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 59 500.3 4-o4.5 29.7 6622 ..77 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 242 Resin finger guards page: p. 539 Counter Rotating Fan San Ace 60 9CRE type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 300 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRE0612P0G001 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] 100 0 Rated current Rated input SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 2.3 0.22 27.6 2.7 16500 13000 3600 2800 2.0 0.43 70.6 15.1 1000 47.6 4.0 0.19 66 32 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRE0612P0G001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 2.0 1.0 0 Static pressure Static pressure PWM duty cycle PWM 100% 4.0 1000 3.0 5.0 DC12 V 12 VDC 1200 800 600 50% 400 200 0 4.0 3.0 2.0 1.0 0% 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m3/min) (CFM) 0 (min-1) PWM100% PWM duty cycle 100% 1200 18000 13.2 V 1000 14000 12 V 800 600 10.8 V 400 16500 min-1 Inlet 13000 min-1 12000 10000 3600 min-1 8000 Outlet 6000 4000 200 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16000 Fan speed (inch H2O) (Pa) 5.0 PWM duty - Speed characteristics example 2000 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m3/min) (CFM) 0 2800 min-1 100 (%) PWM PWM duty cycle 243 Counter Rotating Fan 60 mm sq. DC 60x60x76 mm Dimensions (unit: mm) Outlet side Inlet side 600.5 500.3 500.3 600.5 +50 300 0 (10) (10) 4-o4.30.3 Mounting hole 40.3 +50 300 0 Lead wire AWG26 UL 1430 Rotating direction 40.3 760.5 Airflow direction 4-o4.30.3 Mounting hole Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 59 500.3 4- o4.5 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 244 Resin finger guards page: p. 539 Counter Rotating Fan San Ace 60 9CRA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 270 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CRA0612P0G001 12 10.8 to 13.2 9CRA0612P0S001 PWM duty cycle* [%] 100 0 100 0 Rated current Rated input SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 2.3 0.22 1.5 0.17 27.6 2.7 18.0 2.1 16500 13000 3600 2800 14000 11000 3200 2500 2.0 0.43 1.7 0.38 70.6 15.1 60.0 13.4 1000 47.6 720 37.6 4.0 0.19 2.89 0.15 66 32 63 29 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0612P0G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 12 VDC DC12 V 1200 Static pressure 2.0 1.0 0 800 600 50% 400 200 0 5.0 PWM PWM duty cycle 100% 4.0 1000 3.0 (inch H2O) (Pa) 0% 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) Airflow 3.0 2.0 1.0 0 (min-1) PWM duty cycle 100% PWM100% 1200 18000 13.2 V 4.0 1000 Static pressure 5.0 PWM duty - Speed characteristics example 14000 12 V 800 10.8 V 600 400 16500 min-1 Inlet 13000 min-1 12000 10000 8000 3600 min-1 Outlet 6000 4000 200 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16000 Fan speed PWM duty cycle -1 2000 2800 min 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 245 Counter Rotating Fan 60 mm sq. DC 60x60x76 mm Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0612P0S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 12 VDC DC12 V 5.0 1200 2.0 1.0 0 Static pressure Static pressure 3.0 PWM PWM duty cycle 100% 800 600 50% 400 200 2.0 1.0 0% 0 1.0 0.5 1.5 2.0 0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) Airflow 18000 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 16000 4.0 1000 3.0 (min-1) PWM duty cycle 100% PWM100% 5.0 1200 4.0 1000 PWM duty - Speed characteristics example 800 12 V 600 14000 min-1 14000 13.2 V Fan speed PWM duty cycle 10.8 V 400 12000 Inlet 11000 min-1 10000 8000 3200 min-1 6000 Outlet 4000 200 -1 2000 2500 min 0 100 (%) 0 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) PWM duty cycle PWM Airflow Dimensions (unit: mm) Outlet side Inlet side 600.5 4-o4.50.3 Mounting hole 760.5 (4) (10) 500.3 (4) 500.3 (10) +50 300 0 600.5 +50 300 0 Lead wire AWG26 UL 1430 4-o4.50.3 Mounting hole Rotating direction Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 59 500.3 4- o4.5 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 246 Resin finger guards page: p. 539 Counter Rotating Fan San Ace 80 9CRB type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 430 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRB0812P8G001 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 20 Rated speed [A] [W] [min-1] Inlet Outlet 9.2 0.17 110.4 2.04 14600 12200 2000 1670 Max. airflow [m/min] 5.5 0.7 [CFM] 194 24.7 Max. static pressure [Pa] [inchHO] 1150 4.6 21.6 0.09 SPL Operating temperature Expected life [dB (A)] [C] [h] 80 24 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRB0812P8G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1200 4 1000 3 2 1 0 PWM PWM duty cycle 100% 800 600 60% 400 200 0 20% 1 2 3 4 5 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 Airflow (CFM) 5 1200 4 1000 3 2 (min-1) PWM duty cycle 100% PWM100% 1400 Static pressure Static pressure 5 (inch H2O) (Pa) 12 VDC DC12 V 1400 PWM duty - Speed characteristics example 16000 13.2 V 600 400 1 200 0 0 14600 min-1 12200 min-1 12000 10.8 V 800 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 12 V Fan speed PWM duty cycle 10000 Inlet 8000 6000 Outlet 4000 2000 1 2 3 4 5 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 Airflow (CFM) 0 100 (%) PWM duty cycle PWM 247 Counter Rotating Fan 80 mm sq. DC 80x80x80 mm Dimensions (unit: mm) Inlet side Outlet side Lead wire AWG22 UL 1430 (4) 800.5 71.50.5 (4) 300 71.50.5 (10) +30 0 800.5 4-o4.50.5 Mounting hole 801 4-o4.50.5 Rotating direction Airflow direction Mounting hole Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 78.5 4-o4.5 78.5 71.50.3 o9 0 71.50.3 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 248 Resin finger guards page: p. 539 Counter Rotating Fan San Ace 80 9CRE type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) EExpected life ....................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 490 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRE0812P8G001 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 0 Rated speed Max. airflow [A] [W] [min-1] Inlet Outlet [m/min] [CFM] 5.3 0.2 63.6 2.4 12000 11300 2000 1900 4.5 0.74 158.9 26.1 Max. static pressure [Pa] [inchHO] 1150 4.62 31.9 0.13 SPL Operating temperature Expected life [dB (A)] [C] [h] 76 30 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRE0812P8G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1200 4.0 1000 3.0 2.0 1.0 0 5.0 800 600 50% 400 200 0% 0 1.0 2.0 3.0 4.0 0 20 40 60 80 100 120 140 160 Airflow 1000 3.0 800 2.0 1.0 0 5.0 (m3/min) 12 V/13.2 V 1200 4.0 10.8 V 600 400 200 0 1.0 2.0 3.0 4.0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 (CFM) (min-1) PWM duty cycle 100% PWM100% 1400 PWM PWM duty cycle 100% Static pressure Static pressure 5.0 (inch H2O) (Pa) 12 VDC DC12 V 1400 PWM duty - Speed characteristics example Fan speed PWM duty cycle (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 13000 12000 11000 10000 9000 8000 7000 2000 min-1 6000 5000 4000 3000 2000 1900 min-1 1000 0 12000 min-1 11300 min-1 Inlet Outlet 100 (%) PWM duty cycle PWM Airflow Dimensions (unit: mm) Outlet side Inlet side 800.5 71.50.5 800.5 71.50.5 +50 300 0 (10) (10) 4-o4.30.5 Mounting hole Rotating direction +50 300 0 Lead wire AWG24 UL 1430 40.3 40.3 801 Airflow direction 4-o4.30.5 Mounting hole Rotating direction 249 Counter Rotating Fan 80 mm sq. DC 80x80x80 mm Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 78.5 78.5 4-o4.5 o8 78.5 71.50.3 o9 78.5 71.50.3 4-o4.5 2 71.50.3 0 71.50.3 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 250 Resin finger guards page: p. 539 Counter Rotating Fan San Ace 80 9CRA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 450 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9CRA0812P8G001 12 10.8 to 13.2 9CRA0824P8G001 24 21.6 to 26.4 9CRA0848P8G001 48 40.8 to 55.2 PWM duty cycle* [%] Rated current Rated input 100 0 100 0 100 0 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 5.3 0.2 2.65 0.09 1.32 0.29 63.6 2.4 63.6 2.16 63.4 13.9 12000 11300 2000 1900 12000 11300 2000 1900 12000 11300 5000 4700 4.5 0.74 4.5 0.74 4.5 1.88 158.9 26.1 158.9 26.1 158.9 66.2 1150 31.9 1150 31.9 1150 200 4.62 0.13 4.62 0.13 4.62 0.8 76 30 76 30 76 52 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 567. Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0812P8G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1200 4.0 1000 3.0 2.0 1.0 0 PWM duty cycle PWM 100% 800 600 50% 400 200 0 0% 1.0 2.0 3.0 4.0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 Airflow 5.0 (CFM) 1000 3.0 800 2.0 1.0 0 12 V/13.2 V 1200 4.0 (min-1) PWM duty cycle 100% PWM100% 1400 Static pressure Static pressure 5.0 (inch H2O) (Pa) 12 VDC DC12 V 1400 PWM duty - Speed characteristics example 10.8 V Fan speed PWM duty cycle 600 400 200 0 1.0 2.0 3.0 4.0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 (CFM) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz 12000 min-1 PWM25 12000 11000 Inlet 10000 9000 8000 7000 2000 min-1 6000 5000 4000 3000 2000 1900 min-1 1000 0 11300 min-1 Outlet 100 (%) PWM duty cycle PWM Airflow 251 Counter Rotating Fan 80 mm sq. DC 80x80x80 mm Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0824P8G001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range Static pressure 4.0 1000 2.0 1.0 800 600 50% 400 0% 200 0 0 1.0 2.0 3.0 4.0 2.0 1.0 50% 0% 200 0 0 5.0 100% 400 1.0 200 0 1400 PWM duty cycle PWM 600 400 (inch H2O) (Pa) Static pressure Static pressure 800 600 1.0 2.0 3.0 4.0 5.0 (m3/min) Airflow 48 VDC DC48 V 1200 3.0 1.0 800 2.0 3.0 4.0 Airflow 1000 3.0 800 2.0 1.0 (min-1) 48 V/55.2 V 40.8 V 600 400 200 0 1.0 2.0 3.0 4.0 5.0 (m3/min) 0 20 40 60 80 100120140160 (CFM) Airflow Inlet side (CFM) 4-o4.50.5 (4) 0 (4) 800.5 71.50.5 (10) +30 300 0 Lead wire AWG24 UL 1430 Rotating direction 4-o4.50.5 Airflow direction Mounting hole Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 78.5 78.5 4-o4.5 2 71.50.3 78.5 71.50.3 o9 o8 0 71.50.3 4-o4.5 12000 min-1 11300 min-1 Outlet 100 (%) PWM duty cycle PWM 71.50.5 800.5 801 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 12000 11000 Inlet 10000 9000 8000 5000 min-1 7000 6000 5000 4700 min-1 4000 3000 2000 1000 Outlet side Mounting hole 78.5 100 (%) PWM duty - Speed characteristics example Dimensions (unit: mm) 71.50.3 Outlet 0 PWM duty cycle 100% PWM100% 1200 4.0 0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 252 12000 min-1 11300 min-1 PWM duty cycle PWM (CFM) Operating voltage range 1400 1000 2.0 21.6 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 13000 12000 Inlet 11000 10000 9000 8000 -1 7000 2000 min 6000 5000 4000 3000 2000 1900 min-1 1000 With pulse sensor with PWM control function (inch H2O) (Pa) 4.0 3.0 24 V/26.4 V 0 20 40 60 80 100 120 140 160 PWM duty cycle 5.0 1000 (CFM) Airflow 9CRA0848P8G001 4.0 0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 1200 Fan speed 3.0 5.0 (min-1) PWM duty cycle 100% PWM100% 1400 PWM PWM duty cycle 100% 5.0 1200 Static pressure (inch H2O) (Pa) 24 VDC DC24 V 1400 Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example Options page: p. 532 Resin filter kits page: p. 539 Model no.: 109-1002G DC Model no.: 109-049E, 109-049H Resin finger guards page: p. 540 Counter Rotating Fan 80 mm sq. Finger guards Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 253 Counter Rotating Fan 92x92x76 mm San Ace 92 9CRA type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 510 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRA0912P0G001 [V] [V] 12 10.2 to 13.2 48 9CRA0948P0G601 36 to 60 PWM duty cycle* [%] Rated current Rated input 100 20 100 20 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 9.0 0.42 2.2 0.15 108.0 5.04 105.6 7.2 13300 12200 3500 3200 13300 12200 3500 3200 5.8 1.48 5.8 1.48 205 52.3 205 52.3 1650 140 1650 140 6.63 0.56 6.63 0.56 81 47 81 47 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRA0912P0G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) Static pressure 6 1200 4 1000 3 800 2 1 0 100% 1400 5 60% 600 400 20% 1 2 3 4 5 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 Airflow 254 6 5 800 2 (CFM) 0 12000 10.2 V 1200 600 6000 200 2000 2 3 4 5 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 Airflow (CFM) Inlet 8000 4000 1 13300 min-1 12200 min-1 10000 400 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 14000 12 V 1400 1000 16000 13.2 V 1600 3 (min-1) PWM duty cycle 100% PWM100% 1800 4 1 200 0 7 PWM PWM duty cycle 1600 Static pressure 7 (inch H2O) (Pa) 12 VDC DC12 V 1800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 Outlet 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example Operating voltage range (inch H2O) (Pa) Static pressure 6 1200 4 1000 3 800 1 0 100% 6 1400 5 2 7 PWM PWM duty cycle 1600 Static pressure 7 (inch H2O) (Pa) 48 VDC DC48 V 1800 60% 600 400 20% 1 1000 3 800 2 1 200 0 4 2 3 4 5 0 6 (m3/min) 0 20 40 60 80 100 120 140 160 180 200 Airflow 12000 36 V 600 6000 200 2000 2 3 4 5 6 (m3/min) Airflow Inlet 8000 4000 1 13300 min-1 12200 min-1 10000 400 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 14000 48 V 0 20 40 60 80 100 120 140 160 180 200 (CFM) 16000 60 V 1400 1200 (min-1) PWM duty cycle 100% PWM100% 1800 1600 5 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 Outlet 100 (%) PWM PWM duty cycle (CFM) Dimensions (unit: mm) Inlet side Outlet side 4-o4.50.5 Mounting hole Lead wire AWG22 UL 3266 761 (4) 920.5 82.50.5 (4) 300 82.50.5 920.5 (10) +30 0 4-o4.50.5 Airflow direction Rotating direction Mounting hole Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 90.5 4-o4.5 90.5 82.50.3 7 o9 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 255 DC With pulse sensor with PWM control function Counter Rotating Fan 92 mm sq. 9CRA0948P0G601 Counter Rotating Fan 120x120x76 mm San Ace 120 9CR type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 670 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CR1212P0G03 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 0 Rated speed [min-1] Inlet Outlet [A] [W] 7.2 1.1 86.4 13.2 6200 2700 3800 1800 SPL Operating temperature Expected life [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 8.5 3.8 300 134 480 95 1.93 0.38 70 51 -20 to +60 40000/60C * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CR1212P0G03 With pulse sensor with PWM control function Operating voltage range Static pressure 2.52.5 600 600 500 2.02.0 500 1.51.5 1.01.0 0.50.5 00 400 400 50% 50% 300 300 200 200 00 700 700 2.52.5 600 600 500 2.02.0 500 1.51.5 1.01.0 0% 0% 0.50.5 100 100 00 256 PWM PWM PWM duty cycle 100% 100% (Pa) (inch H2O) (Pa) (inch H2O) 3 3 /min) /min) 2 2 4 4 6 6 8 8 1010 (m(m (CFM) (CFM) 100 200 200 300 300 400 400 100 Airflow 00 400 400 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% PWM100% (min-1) Inlet 10.8 10.8 VV 300 300 200 200 00 2 2 4 4 6 6 8 8 1010 3 3 /min) /min) (m(m (CFM) 100 200 200 300 300 400 400(CFM) 100 Airflow 6200 min-1 6000 2700 min -1 4000 Outlet 2000 100 100 00 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8000 13.2 13.2 VV 1212 VV Fan speed DC12 DC12 V V 12 VDC 700 700 (inch H2O) (Pa) (inch H2O) (Pa) Static pressure PWM duty cycle 0 3800 min-1 1800 min-1 100 (%) PWM duty cycle PWM Dimensions (unit: mm) Inlet side 4-o4.30.3 Mounting hole 761 1200.8 104.80.3 Airflow direction Rotating direction 4-o4.30.3 Mounting hole DC Outlet side Counter Rotating Fan 120 mm sq. +30 300 0 (10) 1200.8 +30 300 0 104.80.3 (10) Lead wire AWG22 UL 1430 Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 4-o4.5 35 o1 118 118 104.80.3 27 o1 4-o4.5 118 104.80.3 104.80.3 118 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1000G page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 257 Counter Rotating Fan o 172x150x102 mm San Ace 172 9CR type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Inlet Outlet Mass ...................................................... 1600 g Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CR5748P9G001 [V] [V] 48 36 to 72 PWM duty cycle* [%] Rated current Rated input 100 0 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 5.5 0.5 264 24 7300 6400 2400 1900 18 5.5 636 194.3 1400 152 5.62 0.61 83 54 -20 to +70 40000/60C * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CR5748P9G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 5 100% 1200 50% 4 1000 3 2 1 0 800 600 400 0% 200 0 5 10 15 20 (m3/min) 0 100 200 300 400 500 600 700 (CFM) Airflow 258 6 PWM PWM duty cycle 1400 Static pressure Static pressure 6 (inch H2O) (Pa) DC48 V 48 VDC 1600 5 1600 PWM duty - Speed characteristics example 2 1 0 8000 72 V 1400 7000 48 V 1200 4 1000 3 (min-1) PWM duty cycle 100% PWM100% Fan speed PWM duty cycle 36 V 800 600 3000 2000 1000 5 10 15 20 (m3/min) Airflow Outlet 4000 200 0 100 200 300 400 500 600 700 (CFM) 7300 min-1 6400 min-1 Inlet 6000 2400 min-1 5000 400 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 0 1900 min-1 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 1021 +30 0 (10) 1500.8 7.50.4 1620.5 (10) +30 300 0 Lead wire Counter Rotating Fan o172 mm 300 7.50.4 o1720.8 4-o4.50.3 Mounting hole 4-o4.50.3 Mounting hole DC Inlet side Outlet side AWG22 UL 1430 .5 55 55 .5 Airflow direction Rotating direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 9.5 1620.5 o1 68 4-o4.5 55 5 .5 147 55. Options Finger guards page: p. 534 Model no.: 109-319J, 109-319E, 109-319H, 109-320 259 260 Reversible Flow Fan Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 9RF 13 12 P 3 H 001 Type name Frame size Voltage PWM control function Frame thickness Speed code Individual customer s spec Type name 9RF Frame size (mm) 09 13 o 92 o 136 Voltage (V) 12 12 24 24 Frame thickness (mm) 1 38 3 28 Speed code H How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 261 Reversible Flow Fan DC The wind directions can be switched with these fans. Equivalent cooling performance can be obtained in both directions. Reversible Flow Fan o 92x38 mm San Ace 92RF 9RF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 150 g Specifications The models listed below have pulse sensors with PWM control function. Airflow Rated voltage Operating voltage range direction [V] [V] Model no. Forward 9RF0912P1H001 Reverse Forward 9RF0924P1H001 Reverse 12 24 10.2 to 13.8 20.4 to 27.6 PWM duty cycle* [%] 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.17 0.17 0.09 0.09 2.0 2.0 2.2 2.2 5500 5300 5500 5300 1.2 1.2 1.2 1.2 42.4 42.4 42.4 42.4 156 146 156 146 [inchHO] 0.63 0.59 0.63 0.59 SPL Operating temperature Expected life [dB (A)] [C] [h] 39 43 39 43 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Operating voltage range Forward Static pressure 160 0.60 0.55 140 0.50 120 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 (inch H2O) (Pa) PWM duty cycle 100% PWM100% 160 13.8 V/12 V 10.2 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Static pressure (inch H2O) (Pa) (m3/min) 0 5 10 15 20 25 30 35 40 45 50 (CFM) Airflow 262 PWM duty - Speed characteristics example Reverse 0.60 0.55 140 0.50 120 0.45 0.40 100 0.35 0.30 80 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 PWM duty cycle 0% PWM0% (min-1) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 13.8 V/12 V 5500 min-1 4000 10.2 V Fan speed 9RF0912P1H001 2000 Forward 0 2000 Reverse 4000 -1 6000 5300 min 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0 5 10 15 20 25 30 35 40 45 50 Airflow (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9RF0924P1H001 With pulse sensor with PWM control function PWM duty cycle 0% PWM0% 160 27.6 V/24 V 20.4 V Static pressure Static pressure 0.60 0.55 140 0.50 120 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 (inch H2O) (Pa) PWM duty cycle 100% PWM100% 160 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0.60 0.55 140 0.50 120 0.45 0.40 100 0.35 0.30 80 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 0 5 10 15 20 25 30 35 40 45 50 (CFM) (min-1) 5500 min-1 Forward 4000 20.4 V 2000 0 2000 Reverse 4000 -1 6000 5300 min 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0 (m3/min) 0 5 10 15 20 25 30 35 40 45 50 Airflow DC24 V Voltage: 24 VDC PWM25 PWM frequency:kHz 25 kHz 6000 27.6 V/24 V Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example Reverse DC Operating voltage range Forward Reversible Flow Fan o92 mm Operating voltage range 100 (%) PWM duty cycle PWM (CFM) Airflow Dimensions (unit: mm) 4-o3.50.3 Mounting hole 300 +30 0 (10) Airflow direction (Forward) Airflow direction (Reverse) 890.5 Lead wire AWG26 UL 1007 (3.5) 380.5 .7 85 0 0 85 .7 (3.5) o920.5 Rotating direction (Forward) Rotating direction (Reverse) Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Impeller side, Nameplate side 45 o88 45 4-o3.5 0 .3 85 50 0 .3 3.5 4-R 85 Options Finger guards page: p. 532 Model no.: 109-1147 263 Reversible Flow Fan o 136x28 mm San Ace 136RF 9RF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 220 g Specifications The models listed below have pulse sensors with PWM control function. Airflow Rated voltage Operating voltage range direction [V] [V] Model no. Forward 9RF1312P3H001 Reverse Forward 9RF1324P3H001 Reverse 12 24 10.2 to 13.8 20.4 to 27.6 PWM duty cycle* [%] 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.15 0.15 0.09 0.09 1.8 1.8 2.2 2.2 3100 3100 3100 3100 2.0 2.0 2.0 2.0 70.7 70.7 70.7 70.7 102 104 102 104 [inchHO] 0.41 0.418 0.41 0.418 SPL Operating temperature Expected life [dB (A)] [C] [h] 35 46 35 46 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Operating voltage range Forward (inch H2O) (Pa) 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 100 80 10.2 V/12 V/13.8 V 60 40 20 0 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow 264 Static pressure Static pressure 0.45 (inch H2O) (Pa) PWM duty cycle 100 PWM100% 120 PWM duty - Speed characteristics example Reverse (CFM) 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 (min-1) PWM duty cycle 0 PWM0% 120 4000 80 10.2 V/12 V/13.8 V 60 40 3100 min-1 2000 1000 Forward 0 1000 Reverse 2000 20 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 3000 100 Fan speed 9RF1312P3H001 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow (CFM) 3000 3100 min-1 4000 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9RF1324P3H001 With pulse sensor with PWM control function 100 0.40 0.35 20.4 V/24 V/27.6 V 80 0.30 0.25 Static pressure Static pressure 0.45 (inch H2O) (Pa) PWM duty cycle 100 PWM100% 120 0.20 60 40 0.15 0.10 20 0.05 0 0 0.5 1.0 1.5 2.0 2.5 (m /min) 3 0 10 20 30 40 50 60 70 80 4000 20.4 V/24 V/27.6 V 80 60 40 3100 min-1 Forward 2000 1000 0 1000 Reverse 2000 20 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 3000 100 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) Airflow 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 (min-1) PWM duty cycle 0 PWM0% 120 Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example Reverse DC Operating voltage range Forward Reversible Flow Fan o136 mm Operating voltage range Airflow (CFM) 3000 3100 min-1 4000 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) 4-o3.50.3 Mounting hole (10) 131.50.5 Airflow +300 direction (Forward) 30 0 Lead wire AWG26 UL 1007 0 (3) 280.5 12 8 .3 0 8 12 .3 (3) Airflow direction (Reverse) o1360.5 (Forward) Rotating direction (Reverse) Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Impeller side, Nameplate side 45 45 4-o3 .5 22 .3 0 12 8 0 8 12 .3 o1 Options Finger guards page: p. 533 Model no.: 109-1139 265 266 Splash Proof Fan Cooling fan of IP54, IP55 and IP68 waterproof capability. For more information on IP rating, refer to p. 553. Related product: Splash Proof Centrifugal Fan p. 329, Oil Proof Fan p. 345 9WS 08 12 H 4 01 Type name Frame size Voltage Speed code Frame thickness Sensor specifications Splash Proof Fan DC Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. Frame form Fans with PWM control function 9WV 08 48 P 1 H Type name Frame size Voltage PWM control function Frame thickness Speed code Type name 001 Individual customer s spec (2 to 3 digits) Frame form 9W 9WB 9WE 9WG 9WL 9WP 9WS 9WV Frame size (mm) 04 06 08 09 12 14 17 40 x 40 60 x 60 80 x 80 92 x 92 120 x 120 140 x 140 Voltage (V) 12 12 Speed code A D Frame thickness (mm) 1 38 Sensor specifications Frame form 24 24 48 48 etc. F G H 5 51 6 20 E 4 25 J L M S 57 o 172 o 172 x 150 (sidecut) etc. 01 02 D01 With a pulse sensor Without a sensor With a lock sensor Nil 1 Plastic frame: Ribbed frame Aluminum frame: Ribless frame Plastic frame: Ribless frame How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 267 Splash Proof Fan IP68 40x40x20 mm San Ace 40W 9WP type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 50 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9WP0412H6001 9WP0412F6001 12 Rated speed Max. airflow [A] [W] [min-1] [m/min] [CFM] [Pa] 7 to 13.8 0.1 0.06 1.2 0.72 8000 6500 0.225 0.183 8.0 6.5 65.7 45.1 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 580. Lock sensor Airflow - Static Pressure Characteristics 9WP0412H6001 9WP0412F6001 With pulse sensor Operating voltage range (inch H2O) (Pa) 13.8 V 80 12 V 60 7V 0.2 40 0.1 0 20 0 0 268 0.25 100 Static pressure Static pressure 0.3 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.4 0.1 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 Max. static pressure [V] (CFM) 60 13.8 V 0.20 0.15 0.10 12 V 40 7V 20 0.05 0 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) [inchHO] 0.264 0.181 SPL [dB (A)] 33 28 Operating temperature Expected life [C] [h] -10 to +60 40000/60C (70000/40C) Dimensions (unit: mm) +1 40 0 4-o3.50.3 Mounting hole 320.3 200.5 (4) (4) +30 320 0 DC 320.3 +1 40 0 (10) Rotating direction Splash Proof Fan 40 mm sq. Lead wire AWG24 UL 1007 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (15) .5 38 320.3 4-o3.7 (15) Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 269 Splash Proof Fan IP68 40x40x28 mm San Ace 40W 9WL type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 70 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9WL0412P3J001 12 10.8 to 13.2 9WL0412P3G001 9WL0424P3J001 24 21.6 to 26.4 9WL0424P3G001 PWM duty cycle* [%] 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow [min-1] [A] [W] 0.52 0.06 0.4 0.06 0.26 0.04 0.2 0.04 6.24 0.72 4.8 0.72 6.24 0.96 4.8 0.96 Max. static pressure [m/min] [CFM] [Pa] 0.63 0.13 0.56 0.12 0.63 0.14 0.56 0.11 22.2 4.6 19.7 4.2 22.2 5.1 19.7 3.8 400 16.9 310 14.0 400 20.9 310 11.6 17500 3600 15500 3300 17500 4000 15500 3000 [inchHO] 1.61 0.07 1.24 0.06 1.61 0.08 1.24 0.05 SPL Operating temperature Expected life [dB (A)] [C] [h] 51 20 47 18 51 22 47 16 -20 to +70 150000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0412P3J001 With pulse sensor with PWM control function Operating voltage range 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 270 (inch H2O) (Pa) 12 VDC DC12 V PWM PWM duty cycle 100% Static pressure Static pressure (inch H2O) (Pa) 50% 20% 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m /min) 3 5 10 15 Airflow 20 25 (CFM) 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 13.2 V 12 V Fan speed PWM duty cycle 10.8 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 10 15 Airflow 20 25 (CFM) 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 17500 min-1 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0412P3G001 With pulse sensor with PWM control function 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM PWM duty cycle 100% 50% 20% 0.1 0.2 0.3 0.4 0.5 0.6 10 5 15 Airflow 9WL0424P3J001 20 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 100% 50% 20% 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 10 15 Airflow 20 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 25 (CFM) 12 V 10.8 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 5 10 15 Airflow 20 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 (m3/min) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 15500 min-1 100 (%) PWM PWM duty cycle 25 (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 26.4 V 24 V 21.6 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 10 15 Airflow 20 25 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 17500 min-1 100 (%) PWM PWM duty cycle (CFM) With pulse sensor with PWM control function Operating voltage range 24 VDC DC24 V PWM duty cycle PWM 100% 50% 20% 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 5 1.8 0 10 15 Airflow 20 (inch H2O) (Pa) Static pressure Static pressure 400 300 13.2 V (inch H2O) (Pa) PWM duty cycle PWM (inch H2O) (Pa) 450 1.2 0 24 VDC DC24 V PWM duty cycle 1.6 350 Operating voltage range 9WL0424P3G001 1.8 400 1.4 25 (CFM) Static pressure Static pressure 1.6 1.6 (min-1) PWM duty cycle 100% PWM100% With pulse sensor with PWM control function (inch H2O) (Pa) 450 450 0 0.7 (m3/min) PWM duty cycle 1.8 1.8 DC 1.6 (inch H2O) (Pa) 12 VDC DC12 V Fan speed 450 25 (CFM) 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 26.4 V 24 V Fan speed 1.8 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example 21.6 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 5 10 15 Airflow 20 (m3/min) 25 (CFM) 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 15500 min-1 100 (%) PWM duty cycle PWM 271 Splash Proof Fan 40 mm sq. Operating voltage range Fan speed PWM duty cycle Dimensions (unit: mm) 8-o3.50.3 Mounting hole 320.3 400.5 +30 320 0 320.3 400.5 Lead wire (10) AWG28 UL 3266 40.3 40.3 280.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side (17.6) 39 4-o3.7 40 (17.6) 320.3 39 320.3 Options Finger guards Model no.: 109-059, 109-059H 272 page: p. 532 Splash Proof Fan IP68 60x60x25 mm General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 60 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 120 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9WL0612P4S001 12 9WL0612P4J001 10.8 to 13.2 9WL0612P4H001 9WL0624P4S001 24 9WL0624P4J001 21.6 to 26.4 9WL0624P4H001 PWM duty cycle* [%] 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow [min-1] [A] [W] 0.67 0.06 0.39 0.03 0.17 0.03 0.34 0.03 0.19 0.02 0.08 0.02 8.04 0.72 4.68 0.36 2.04 0.36 8.16 0.72 4.56 0.48 1.92 0.48 11000 2900 8650 1150 6150 1350 11000 2900 8650 2200 6150 1300 Max. static pressure [m/min] [CFM] [Pa] 1.4 0.36 1.1 0.13 0.78 0.17 1.4 0.36 1.1 0.28 0.78 0.16 49.4 12.7 38.8 4.8 27.5 6.0 49.4 12.7 38.8 9.8 27.5 5.6 300 20.8 182 3.3 97 4.7 300 20.8 182 12.0 97 4.3 [inchHO] 1.204 0.083 0.73 0.013 0.389 0.018 1.204 0.083 0.73 0.048 0.389 0.017 SPL Operating temperature Expected life [dB (A)] [C] [h] 53 20 47 14 36 14 53 20 47 17 36 14 -20 to +70 180000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 579. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0612P4S001 With pulse sensor with PWM control function Operating voltage range 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) DC12 V 12 VDC PWM duty cycle PWM 100% Static pressure Static pressure (inch H2O) (Pa) 50% 20% 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 10 20 30 40 Airflow 50 (CFM) 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 13.2 V 12 V Fan speed PWM duty cycle 10.8 V 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 10 20 30 40 Airflow 50 (CFM) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 DC San Ace 60W 9WL type Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 11000 min-1 100 (%) PWM PWM duty cycle 273 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0612P4J001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) DC12 V 12 VDC 1.2 300 PWM duty cycle PWM 100% 0.6 150 50% 0.4 100 20% 10 20 30 Airflow 9WL0612P4H001 40 50 25 PWM duty cycle PWM 100% 50% 20% 0 5 10 15 20 25 30 35 Airflow 9WL0624P4S001 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 50% 20% 20 30 40 Airflow 9WL0624P4J001 50 250 0.8 200 0.6 150 0.4 100 0.2 50 0 274 5 10 15 20 25 30 35 Airflow 1.6 400 4000 3000 2000 100 (%) PWM PWM duty cycle (CFM) 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 26.4 V 24 V 21.6 V 0 10 20 30 40 Airflow 50 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 11000 min-1 100 (%) PWM duty cycle PWM (CFM) 30 Airflow 40 50 (min-1) 1.0 250 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 20 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.2 300 20% 10 5000 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) (inch H2O) (Pa) 24 VDC DC24 V 50% 0 0 Operating voltage range PWM duty cycle PWM 100% 0 6150 min-1 6000 1000 0 Static pressure Static pressure 1.0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 300 25 (CFM) PWM duty cycle 1.2 0.1 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 10 50 (min-1) 7000 10.8 V (inch H2O) (Pa) PWM duty cycle PWM 100% 0 0.2 PWM duty - Speed characteristics example Operating voltage range 24 VDC DC24 V 0 100 (%) PWM PWM duty cycle 50 (CFM) 12 V 75 0 Static pressure Static pressure 1.4 8650 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 400 0.3 (CFM) PWM duty cycle 1.6 Airflow 40 13.2 V 0.4 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 30 PWM duty cycle 100% PWM100% 0.5 125 Static pressure Static pressure 0.1 0 (inch H2O) (Pa) DC12 V 12 VDC 75 50 20 Operating voltage range 0.5 125 0.2 10 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 5000 4000 3000 2000 1000 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 10000 9000 8000 7000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.3 0 (CFM) PWM duty cycle 0.4 100 50 Fan speed 0 0.2 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 10.8 V 0.4 100 Fan speed 0 12 V 0.6 150 (CFM) 26.4 V 0.8 200 Fan speed 0 50 13.2 V 0.8 200 Fan speed Static pressure Static pressure 1.0 250 0.8 200 0.2 (min-1) PWM duty cycle 100% PWM100% 1.2 300 1.0 250 PWM duty - Speed characteristics example 24 V 0.6 150 21.6 V 0.4 100 0.2 0 50 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 10 20 30 Airflow 40 50 (CFM) 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8650 min-1 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0624P4H001 With pulse sensor with PWM control function 0.2 50 0.1 25 0 Static pressure Static pressure 75 50% 20% 0 50 0.1 25 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.91.0 (m3/min) 0 5 10 15 20 25 30 35 Airflow 21.6 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6150 min-1 5000 4000 3000 2000 1000 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (m3/min) 0 (CFM) 6000 24 V 75 0.2 7000 26.4 V 0.4 100 0.3 (min-1) PWM duty cycle 100% PWM100% 0.5 125 PWM PWM duty cycle 100% 0.4 100 0.3 (inch H2O) (Pa) 24 VDC DC24 V 0.5 125 DC (inch H2O) (Pa) PWM duty - Speed characteristics example Splash Proof Fan 60 mm sq. Operating voltage range Fan speed PWM duty cycle 5 10 15 20 25 30 35 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 300 500.3 600.5 8-o4.30.3 Mounting hole +50 0 (10) Lead wire AWG26 UL 1430 500.3 600.5 Rotating direction 40.3 40.3 250.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards Model no.: 109-139E, 109-139H page: p. 532 Resin finger guards page: p. 539 Model no.: 109-1003G 275 Splash Proof Fan IP68 60x60x25 mm San Ace 60W 9WP type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 110 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input [V] 9WP0612G401 9WP0612D401 9WP0612H401 9WP0624J401 9WP0624G401 9WP0624H401 9WP0648H401 12 48 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 10.2 to 13.2 0.21 0.21 0.11 0.2 0.13 0.06 0.04 2.52 2.52 1.32 4.8 3.12 1.44 1.92 5600 5150 3800 7600 5600 3800 3800 0.78 0.72 0.53 1.06 0.78 0.53 0.53 27.5 25 18.7 37.1 27.5 18.7 18.7 87.3 73.5 40.2 155.0 87.3 40.2 40.2 10.2 to 13.8 21.6 to 26.4 24 Rated speed [V] 20.4 to 27.6 40 to 53 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 39 37 28 44 39 28 28 -20 to +60 40000/60C -20 to +70 60000/60C -20 to +60 40000/60C -20 to +70 60000/60C 0.351 0.3 0.161 0.622 0.351 0.161 0.161 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 580. Without sensor Lock sensor PWM control Airflow - Static Pressure Characteristics 9WP0612D401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) Static pressure 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 110 100 90 80 70 60 50 40 30 20 10 0 13.2 V 12 V 10.2 V 60 0.30 0.25 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 5 10 15 20 25 30 Airflow (CFM) 0.25 0.20 80 13.8 V 60 12 V 0.20 0.15 0.10 0.05 0 276 (inch H2O) (Pa) 0.40 100 0.35 0 10.2 V 40 20 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 5 10 15 20 25 30 Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.45 9WP0612H401 With pulse sensor Static pressure 9WP0612G401 (CFM) 0.15 0.10 13.8 V 50 12 V 40 10.2 V 30 20 0.05 0 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 25 (CFM) Airflow - Static Pressure Characteristics 9WP0624G401 Operating voltage range Operating voltage range (inch H2O) (Pa) 24 V 21.6 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 5 10 15 20 25 30 35 40 45 Airflow 9WP0648H401 0.20 27.6 V 24 V 20.4 V 5 10 15 20 25 30 Airflow 0.15 0.10 60 27.6 V 50 24 V 40 20.4 V 30 20 0.05 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m3/min) 0 (CFM) 0.25 Static pressure 26.4 V 0.45 110 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0 0 With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure Static pressure (inch H2O) (Pa) 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 9WP0624H401 With pulse sensor 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 (CFM) DC With pulse sensor 5 10 15 Airflow 20 25 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.25 Static pressure 0.20 0.15 0.10 0.05 0 60 53 V 50 48 V 40 30 40 V 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m3/min) 0 5 10 15 Airflow 20 Dimensions (unit: mm) 25 (CFM) (With ribs) +1 60 0 500.3 250.5 4-o4.30.3 Mounting hole (3) (3) +50 300 0 500.3 +1 60 0 Lead wire AWG24 UL 1007 (10) Rotating direction Airflow direction 277 Splash Proof Fan 60 mm sq. 9WP0624J401 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards Model no.: 109-139E, 109-139H 278 page: p. 532 Resin finger guards Model no.: 109-1003G page: p. 539 Splash Proof Fan IP68 80x80x25 mm General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 80 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 150 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9WL0812P4J001 9WL0812P4G001 12 10.8 to 13.2 9WL0812P4H001 9WL0824P4J001 9WL0824P4G001 24 21.6 to 26.4 9WL0824P4H001 100 20 100 25 100 25 100 20 100 20 100 30 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.6 0.06 0.3 0.05 0.12 0.04 0.28 0.05 0.14 0.02 0.05 0.02 7.2 0.72 3.6 0.6 1.44 0.48 6.72 1.2 3.36 0.48 1.2 0.48 7400 1800 5500 1400 3700 1100 7400 2400 5500 1200 3700 1100 2.07 0.5 1.54 0.39 1.03 0.3 2.07 0.67 1.54 0.33 1.03 0.3 73.0 17.6 54.3 13.7 36.3 10.5 73.0 23.6 54.3 11.6 36.3 10.5 177 10.4 98 6.3 44 3.9 177 18.6 98 4.6 44 3.9 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 49 16 43 14 31 13 49 22 43 13 31 13 -20 to +70 180000/60C 0.71 0.04 0.39 0.02 0.17 0.01 0.71 0.07 0.39 0.01 0.17 0.01 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 579. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Model no. 9WL0812L4001 9WL0824F4001 Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 12 24 8 to 13.2 12 to 26.4 0.06 0.045 0.72 1.08 2300 3300 0.64 0.92 22.6 32.5 17 35 [inchHO] 0.068 0.14 SPL DC San Ace 80W 9WL type Operating temperature Expected life [dB (A)] [C] [h] 22 29 -20 to +70 180000/60C The following sensor and control options are available for selection. Available for all models. Without sensor 279 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0812P4J001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.1 0 0 0 60% 1.0 20 2.0 1.5 40 60 0 0.5 Static pressure Static pressure 25% 100% 60% 1.0 1.5 Airflow 100% 60% 25% 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) PWM duty - Speed characteristics example (min-1) 6000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5500 min-1 5000 13.2 V 12 V 10.8 V 4000 3000 2000 1000 0 0.5 1.0 1.5 0 2.0 (m3/min) 100 (%) PWM PWM duty cycle (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 60 55 50 45 40 35 30 25 20 15 10 5 4000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 3700 min-1 3500 13.2 V 12 V 10.8 V 3000 2500 2000 1500 1000 500 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 5 10 15 20 25 30 35 40 (CFM) Airflow 100 (%) PWM PWM duty cycle (CFM) With pulse sensor with PWM control function (inch H2O) (Pa) 24 VDC DC24 V 0.8 0.7 Static pressure PWM duty cycle PWM 100% 60% 20% 20 100 (%) PWM PWM duty cycle (CFM) Operating voltage range 0.5 0 2.5 (m3/min) 80 Airflow Static pressure Static pressure Static pressure 280 2.0 60 PWM duty cycle 100% PWM100% 120 110 100 90 80 70 60 50 40 30 20 10 (inch H2O) (Pa) PWM duty cycle PWM (inch H2O) (Pa) 0 1.5 40 0 10 20 30 40 50 60 70 12 VDC DC12 V PWM duty cycle 0 1.0 20 Operating voltage range 9WL0824P4J001 3000 With pulse sensor with PWM control function Airflow 0 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 2.0 (m3/min) 0 5 10 15 20 25 30 35 40 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0.5 Airflow (inch H2O) (Pa) 0 0 10 20 30 40 50 60 70 (CFM) 9WL0812P4H001 0 4000 1000 (inch H2O) (Pa) PWM duty cycle PWM 60 55 50 45 40 35 30 25 20 15 10 5 5000 2000 0 DC12 V 12 VDC PWM duty cycle 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 6000 12 V 10.8 V Operating voltage range 120 110 100 90 80 70 60 50 40 30 20 10 0 7400 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0 0.2 (CFM) PWM duty cycle 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.3 0 2.5 (m3/min) 80 Airflow 9WL0812P4G001 0.4 0.1 20% 0.5 0.5 13.2 V 0.2 0.6 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 Fan speed 0.3 0.7 8000 0.4 PWM duty cycle PWM 100% (min-1) PWM duty cycle 100% PWM100% 200 180 160 140 120 100 80 60 40 20 Fan speed 0.5 0.8 0.6 0.5 0.4 0.3 0.2 0.1 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 200 180 160 140 120 100 80 60 40 20 8000 7000 26.4 V 24 V 21.6 V 0.6 (inch H2O) (Pa) 12 VDC DC12 V Fan speed Static pressure 0.7 200 180 160 140 120 100 80 60 40 20 Static pressure 0.8 PWM duty - Speed characteristics example Fan speed PWM duty cycle Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7400 min-1 6000 5000 4000 3000 2000 1000 0 0.5 0 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 0 1.0 1.5 10 20 30 40 50 60 70 Airflow 9WL0824P4H001 70% 30% Airflow 10 0 (min-1) 4000 26.4 V 24 V 21.6 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 3700 min-1 3000 2500 2000 1500 1000 500 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM With pulse sensor Operating voltage range 13.2 V 12 V 8V 5 0 0 PWM duty - Speed characteristics example Airflow Static pressure Static pressure 0.04 100 (%) PWM duty cycle PWM (CFM) (inch H2O) (Pa) 20 15 2000 0 2.0 (m3/min) 0 5 10 15 20 25 30 35 40 25 0.06 3000 3500 9WL0824F4001 With pulse sensor (inch H2O) (Pa) 0.02 0 (CFM) Operating voltage range 0.08 1.5 PWM duty cycle 100% PWM100% 60 55 50 45 40 35 30 25 20 15 10 5 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 5 10 15 20 25 30 35 40 0.10 1.0 Airflow (inch H2O) (Pa) 24 VDC DC24 V 9WL0812L4001 0.5 Operating voltage range PWM duty cycle PWM 100% 0 4000 1000 0 10 20 30 40 50 60 70 Static pressure Static pressure 0 24 V 21.6 V With pulse sensor with PWM control function (inch H2O) (Pa) 60 55 50 45 40 35 30 25 20 15 10 5 26.4 V 0 (CFM) PWM duty cycle 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 2.0 (m3/min) 5500 min-1 DC 0.5 60% Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 0 100% 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 6000 0 20% PWM duty cycle PWM (min-1) PWM duty cycle 100% PWM100% 120 110 100 90 80 70 60 50 40 30 20 10 Fan speed 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 (inch H2O) (Pa) 24 VDC DC24 V 120 110 100 90 80 70 60 50 40 30 20 10 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.2 5 0.4 10 15 0.6 20 Airflow 0.8 25 (m3/min) (CFM) 0.18 45 0.16 40 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 26.4 V 24 V 12 V 0.2 0.4 0.6 0.8 1.0 1.2 10 20 30 Airflow 40 (m3/min) (CFM) 281 Splash Proof Fan 80 mm sq. 9WL0824P4G001 Dimensions (unit: mm) 71.50.3 800.5 8-o4.30.3 Mounting hole +50 300 0 (10) 71.50.3 800.5 Lead wire AWG26 UL 1430 Rotating direction 40.3 40.3 25.20.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 0 78.5 71.50.3 o9 78.5 Options Finger guards Model no.: 109-049E, 109-049H, 109-049C 282 page: p. 532 Resin finger guards Model no.: 109-1002G page: p. 539 Splash Proof Fan IP68 80x80x25 mm General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 80 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 130 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input 9WP0812G401 9WP0812H401 9WP0824S401 9WP0824H401 9WP0848S401 Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 12 10.8 to 13.2 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 0.38 0.13 0.1 0.07 0.06 4.56 1.56 2.4 1.68 2.88 4500 2900 3400 2900 3400 1.5 1.03 1.2 1.03 1.2 53 36.4 42.4 36.4 42.4 80.4 35.3 48.0 35.3 48.0 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 40 29 34 29 34 -20 to +60 40000/60C 60000/60C 40000/60C 60000/60C 40000/60C 0.323 0.142 0.193 0.142 0.193 -20 to +70 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 580. Lock sensor PWM control Airflow - Static Pressure Characteristics 9WP0812G401 9WP0812H401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.30 0.25 0.20 0.15 0.10 0.05 0 (inch H2O) (Pa) (inch H2O) (Pa) 13.2 V 12 V 10.8 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 (m3/min) 0 10 20 30 40 50 60 Airflow (CFM) 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 With pulse sensor Operating voltage range 50 70 0.25 40 13.8 V 12 V 10.2 V 30 Static pressure Static pressure 0.35 100 90 80 70 60 50 40 30 20 10 0 Static pressure 0.40 9WP0824S401 With pulse sensor 20 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 60 0.20 50 0.15 40 0.10 0.05 0 27.6 V 24 V 30 20.4 V 20 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 DC San Ace 80W 9WP type (CFM) 283 Airflow - Static Pressure Characteristics 9WP0824H401 9WP0848S401 With pulse sensor Operating voltage range With pulse sensor Operating voltage range (inch H2O) (Pa) 0.30 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 50 0.25 40 Static pressure Static pressure (inch H2O) (Pa) 27.6 V 24 V 20.4 V 30 20 10 0 0.5 0 10 20 Airflow 40 50 Dimensions (unit: mm) 800.5 71.50.3 0.10 55.2 V 60 48 V 50 40.8 V 40 30 20 0.05 0 10 0 0.5 0 (CFM) 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) (With ribs) 4-o4.30.3 Mounting hole (3) 250.5 (3) +30 300 0 71.50.3 800.5 0.15 1.5 (m3/min) 1.0 30 0.20 70 (10) Lead wire AWG24 UL 1007 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards Model no.: 109-049E, 109-049H, 109-049C 284 page: p. 532 Resin finger guards Model no.: 109-1002G page: p. 539 Splash Proof Fan IP54 80x80x25 mm General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 80 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 120 g Ingress protection ................................. IP54 Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9WS0812H401 9WS0812F401 9WS0812M401 9WS0824H401 9WS0824F401 9WS0824M401 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.16 0.13 0.1 0.09 0.07 0.05 1.92 1.56 1.2 2.16 1.68 1.2 3100 2700 2200 3100 2700 2200 0.94 0.83 0.65 0.94 0.83 0.65 33.2 29.3 23.0 33.2 29.3 23.0 45.1 34.3 23.5 45.1 34.3 23.5 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 32 28 23 32 28 23 -20 to +70 40000/60C 0.181 0.138 0.094 0.181 0.138 0.094 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 581. Lock sensor Airflow - Static Pressure Characteristics 9WS0812H401 9WS0812F401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.15 50 13.8 V 40 12 V 30 0.10 0.05 0 10.2 V 20 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0.15 (inch H2O) (Pa) 50 0.20 13.8 V 40 Static pressure Static pressure 0.20 0.20 12 V 30 10.2 V 0.10 20 0.05 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 60 Static pressure 0.25 9WS0812M401 With pulse sensor 10 0 0.5 0 10 20 1.0 30 Airflow (m3/min) 40 (CFM) 0.15 50 40 13.8 V 30 12 V 0.10 20 0.05 0 10.2 V 10 0 0 10 0.5 20 1.0 30 Airflow (m3/min) 40 DC San Ace 80WS 9WS type (CFM) 285 Airflow - Static Pressure Characteristics 9WS0824H401 9WS0824F401 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.15 50 27.6 V 40 24 V 30 0.10 0.05 0 20.4 V 20 10 0 0.5 0 10 20 30 Airflow 40 50 Dimensions (unit: mm) 0.20 27.6 V 40 24 V 30 20.4 V 0.10 20 0.05 0 1.5 (m3/min) 1.0 0.15 (inch H2O) (Pa) 50 10 0 0.5 0 (CFM) Static pressure Static pressure 0.20 0.20 With pulse sensor Operating voltage range (inch H2O) (Pa) 60 Static pressure 0.25 9WS0824M401 With pulse sensor 10 20 1.0 30 Airflow 0.15 40 27.6 V 30 24 V 0.10 20 0.05 (m3/min) 40 50 (CFM) 0 20.4 V 10 0 0 10 0.5 20 1.0 30 Airflow (m3/min) 40 (CFM) (With ribs) +30 300 0 71.50.3 800.5 4-o4.30.3 Mounting hole (10) Lead wire AWG24 UL 1007 71.50.3 (4) (4) 250.5 800.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 0 78.5 71.50.3 o9 78.5 Options Finger guards Model no.: 109-049E, 109-049H, 109-049C 286 page: p. 532 Resin finger guards Model no.: 109-1002G page: p. 539 Splash Proof Fan IP68 80x80x38 mm General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 80 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 235 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Model no. [V] [V] 12 9WV0812P1M001 10.2 to 13.8 48 9WV0848P1H001 40.8 to 52.8 PWM duty cycle* [%] 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.75 0.09 0.75 0.15 9 1.08 36 7.2 6000 1700 9700 4500 2.29 0.65 3.7 1.72 80.9 23 131 60.7 169 13.6 440 94.7 [inchHO] 0.68 0.05 1.77 0.38 SPL Operating temperature Expected life [dB (A)] [C] [h] 51 19 63 43 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 581. Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WV0812P1M001 With pulse sensor with PWM control function Operating voltage range 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 200 150 (inch H2O) (Pa) 12 VDC DC12 V 250 Static pressure Static pressure (inch H2O) (Pa) PWM PWM duty cycle 100% 100 50 0% 0 0 1 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 250 7000 12 V 150 10.2 V 100 50 6000 min-1 5000 4000 3000 2000 1700 min-1 1000 0 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 13.8 V 200 Fan speed PWM duty cycle 1 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 0 DC San Ace 80W 9WV type 100 (%) PWM duty cycle PWM 287 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WV0848P1H001 With pulse sensor with PWM control function Operating voltage range 2.0 500 1.6 400 1.2 300 (inch H2O) (Pa) 48 VDC DC48 V PWM duty cycle PWM 100% Static pressure Static pressure (inch H2O) (Pa) 50% 0.8 200 0.4 100 0 0% 0 1 2 0 20 40 60 3 500 1.6 400 1.2 300 0.8 200 0.4 100 80 100 120 140 (CFM) (min-1) PWM duty cycle 100% PWM100% 52.8 V 48 V 0 4 (m3/min) 40.8 V 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow Dimensions (unit: mm) 2.0 PWM duty - Speed characteristics example Fan speed PWM duty cycle Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 11000 10000 9000 8000 7000 6000 5000 4500 min-1 4000 3000 2000 1000 0 9700 min-1 100 (%) PWM duty cycle PWM Airflow (With ribs) 4-o4.30.3 hole Mounting Lead wire AWG24 UL 1430 800.5 71.50.3 +30 300 0 (10) (4) (4) 380.5 71.50.3 800.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 0 78.5 71.50.3 o9 71.50.3 78.5 Options Finger guards Model no.: 109-049E, 109-049H, 109-049C 288 page: p. 532 Resin finger guards Model no.: 109-1002G page: p. 539 Splash Proof Fan IP68 92x92x25 mm General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 92 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 170 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9WL0912P4J001 9WL0912P4G001 12 10.8 to 13.2 9WL0912P4S001 9WL0912P4H001 9WL0924P4J001 9WL0924P4S001 24 21.6 to 26.4 9WL0924P4H001 100 20 100 20 100 30 100 30 100 20 100 30 100 30 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.42 0.04 0.3 0.04 0.22 0.04 0.15 0.04 0.21 0.02 0.11 0.02 0.07 0.02 5.04 0.48 3.6 0.48 2.64 0.48 1.8 0.48 5.04 0.48 2.64 0.48 1.68 0.48 5000 1200 4400 1000 3850 1400 3150 1100 5000 1100 3850 1300 3150 1000 2.2 0.52 1.93 0.43 1.69 0.61 1.38 0.48 2.2 0.48 1.69 0.57 1.38 0.43 77.7 18.4 68.2 15.1 59.7 21.5 48.7 16.9 77.7 16.9 59.7 20.1 48.7 15.1 105 6.04 81 4.18 62.1 8.21 41.6 5.07 105 5.07 62.1 7.08 41.6 4.18 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 44 11 40 8 37 13 32 9 44 9 37 12 32 8 -20 to +70 180000/60C 0.42 0.024 0.33 0.016 0.25 0.032 0.17 0.02 0.42 0.02 0.25 0.028 0.17 0.016 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 579. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Model no. 9WL0912M4001 9WL0924F40 01 9WL0924M4001 Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 12 10.2 to 13.8 24 20.4 to 27.6 0.08 0.05 0.04 0.96 1.2 0.96 2400 2800 2400 1.05 1.22 1.05 37.1 43.1 37.1 24.1 32.8 24.1 [inchHO] 0.097 0.13 0.097 SPL DC San Ace 92W 9WL type Operating temperature Expected life [dB (A)] [C] [h] 24 29 24 -20 to +70 180000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 579. Lock sensor 289 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0912P4J001 With pulse sensor with PWM control function Operating voltage range 80 60 40 50% 20 20% 0 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 9WL0912P4G001 1.0 1.5 2.0 Static pressure Static pressure 9WL0912P4S001 50% 30% 0.5 1.0 1.5 2.5 (m3/min) 3000 2000 0 100 (%) PWM PWM duty cycle (CFM) 0.15 0.10 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 5000 10.8 V 40 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 12 V 0.20 0.20 20 50% 0.15 0.10 0.05 30% 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow 290 2.0 13.2 V 60 20 3850 min-1 3000 2000 1000 0 60 PWM duty cycle PWM 100% 0.5 80 0.5 (inch H2O) (Pa) DC12 V 12 VDC 30 0 1.5 1.0 1.5 0 2.0 (m3/min) 100 (%) PWM PWM duty cycle Airflow Static pressure Static pressure 0 1.0 0.5 0 10 20 30 40 50 60 70 (CFM) 50 10 10.8 V Operating voltage range 60 0.05 4400 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0.10 5000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 1000 (CFM) PWM duty cycle 40 0.25 0 2.0 (m3/min) Airflow 0.15 (min-1) 0.05 0 10 20 30 40 50 60 70 0.20 12 V Airflow Static pressure Static pressure 40 9WL0912P4H001 100 (%) PWM PWM duty cycle (CFM) PWM duty - Speed characteristics example 0 10 20 30 40 50 60 70 80 0.30 PWM duty cycle PWM 100% 0 0 2.5 (m3/min) 13.2 V (inch H2O) (Pa) 0.20 0 2000 4000 0 (CFM) DC12 V 12 VDC 0.05 2.0 Operating voltage range 80 20 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.10 1.5 PWM duty cycle 100% PWM100% 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 2.5 (m3/min) PWM duty cycle 0.15 0.5 1.0 Airflow 20% 60 0 120 50% Airflow 0.25 5000 min-1 1000 20 (inch H2O) (Pa) PWM duty cycle PWM 100% 0 10 20 30 40 50 60 70 80 0.30 40 0 10 20 30 40 50 60 70 80 DC12 V 12 VDC 0.5 10.8 V 60 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 12 V 80 Operating voltage range 120 0 5000 With pulse sensor with PWM control function (inch H2O) (Pa) 0 13.2 V (CFM) PWM duty cycle 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 2.5 (m3/min) 100 (min-1) Fan speed 100 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 PWM duty cycle 100% PWM100% Fan speed 0 PWM duty cycle PWM 100% 120 (CFM) 0 50 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 5000 40 12 V 30 10.8 V 20 3000 3150 min-1 2000 1000 10 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 13.2 V Fan speed 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 (inch H2O) (Pa) 12 VDC DC12 V 120 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0924P4J001 With pulse sensor with PWM control function Operating voltage range 50% 20% 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 9WL0924P4S001 50% 0.05 0.5 1.0 1.5 Airflow 9WL0924P4H001 50% 0.5 1.0 1.5 Airflow 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 DC (min-1) 5000 24 V 21.6 V 12 V 10.2 V 0.2 0.4 0.6 0.8 1.0 1.2 20 30 Airflow 40 (m3/min) (CFM) 2000 1000 0 0.5 1.0 1.5 Airflow 0.25 60 0.20 50 0.15 0.05 0 9WL0924M4001 With pulse sensor Operating voltage range (inch H2O) (Pa) 27.6 V 40 24 V 20.4 V 20 10 0 0 PWM PWM duty cycle (CFM) With pulse sensor 30 0.10 100 (%) 0 2.0 (m3/min) 0 10 20 30 40 50 60 70 Operating voltage range 13.8 V 3150 min-1 3000 10 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 (inch H2O) (Pa) 10 PWM PWM duty cycle PWM duty - Speed characteristics example 20 0.05 Static pressure Static pressure 0.12 100 (%) 0 2.0 (m3/min) 26.4 V 9WL0924F4001 With pulse sensor (inch H2O) (Pa) 35 1.5 PWM duty cycle 100% PWM100% 30 0.10 (CFM) Operating voltage range 0.14 1.0 40 0.15 2.0 (m3/min) 0 10 20 30 40 50 60 70 9WL0912M4001 0.5 50 30% 0 2000 Airflow Static pressure Static pressure 0 3000 0 10 20 30 40 50 60 70 (CFM) 0.20 PWM duty cycle PWM 100% 10 0 60 20 0.05 3850 min-1 1000 (inch H2O) (Pa) DC24 V 24 VDC 30 0.10 20 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 Operating voltage range 60 40 5000 21.6 V 40 0.10 (min-1) 24 V 0.20 0.15 PWM duty - Speed characteristics example With pulse sensor with PWM control function (inch H2O) (Pa) 0.15 PWM PWM duty cycle (CFM) 26.4 V 60 (CFM) PWM duty cycle 50 100 (%) 0 2.5 (m3/min) PWM duty cycle 100% PWM100% 80 0.25 2.0 (m3/min) 0 10 20 30 40 50 60 70 0.20 2.0 0.05 30% 0 1.5 Fan speed Static pressure Static pressure PWM duty cycle PWM 100% 20 0.5 1.0 Airflow 0.30 40 0 0 (inch H2O) (Pa) 0.20 0.10 1000 0 10 20 30 40 50 60 70 80 DC24 V 24 VDC 60 2000 20 Operating voltage range 80 0.15 40 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.25 21.6 V 60 5000 min-1 4000 24 V 80 (CFM) PWM duty cycle 0.30 26.4 V 100 0 2.5 (m3/min) 5000 Fan speed 0 120 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 0.5 10 20 1.0 30 Airflow 1.5 40 50 (m3/min) (CFM) 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 27.6 V 24 V 20.4 V 0.2 0.4 0.6 0.8 1.0 1.2 10 20 30 Airflow 40 (m3/min) (CFM) 291 Splash Proof Fan 92 mm sq. PWM duty cycle PWM 100% (min-1) PWM duty cycle 100% PWM100% Static pressure 120 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 (inch H2O) (Pa) DC24 V 24 VDC Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Dimensions (unit: mm) 920.5 82.50.3 8-o4.30.3 Mounting hole +50 300 0 (10) 82.50.3 920.5 Lead wire AWG26 UL 1430 Rotating direction 40.3 40.3 25.20.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 90.5 Outlet side 90.5 4-o4.5 08 90.5 90.5 82.50.3 7 o9 4-o4.5 82.50.3 o1 82.50.3 Inlet side 82.50.3 Options Finger guards Model no.: 109-099E, 109-099H, 109-099C 292 page: p. 532 Resin finger guards Model no.: 109-1001G page: p. 539 Splash Proof Fan IP68 92x92x25 mm General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 92 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 120 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9WP0912S401 9WP0912F401 9WP0924G401 9WP0924S401 9WP0924H401 9WP0924F401 9WP0924B401 [V] 12 6 to 13.8 24 12 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.27 0.14 0.19 0.15 0.1 0.08 0.05 3.24 1.68 4.56 3.6 2.4 1.92 1.2 3550 2650 3900 3550 3150 2650 2000 1.66 1.24 1.76 1.66 1.45 1.24 0.9 58.6 43.8 62.2 58.6 51.2 43.8 31.8 56.1 32.2 66.5 56.1 44 32.2 18.0 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.225 0.129 0.267 0.225 0.177 0.129 0.072 [C] 39 30 43 39 33 30 23 [h] -20 to +70 40000/60C -10 to +70 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 580. Without sensor Lock sensor Airflow - Static Pressure Characteristics 9WP0912S401 9WP0912F401 With pulse sensor Operating voltage range Operating voltage range 60 0.20 50 0.10 13.8 V 12 V 40 30 20 0.05 10 0 0 6V 0.5 0 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0.15 (inch H2O) (Pa) 0.40 100 50 0.35 40 Static pressure 70 0.25 0.15 0.20 Static pressure Static pressure 80 13.8 V 30 12 V 0.10 20 0.05 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.30 9WP0924G401 With pulse sensor 6V 10 0.30 0.25 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 27.6 V 24 V 0.20 0.15 0.10 0.05 0 80 60 0 40 20 0 12 V 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow DC San Ace 92W 9WP type (CFM) 293 Airflow - Static Pressure Characteristics 9WP0924S401 9WP0924H401 With pulse sensor Operating voltage range Operating voltage range 0.20 50 0.15 40 0.10 0.20 60 27.6 V 24 V 30 20 0.05 10 0 0 12 V 0.5 1.0 1.5 2.0 2.5 0.15 0.10 0.05 0 (m3/min) 50 50 27.6 V 40 24 V 30 20 12 V 10 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 80 90 (CFM) Airflow Airflow 9WP0924B401 (inch H2O) (Pa) 60 Static pressure 70 Static pressure Static pressure 0.25 0.25 80 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.12 30 Static pressure 0.10 0.08 27.6 V 20 24 V 0.06 0.04 12 V 10 0.02 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 10 20 30 Airflow 40 (CFM) Dimensions (unit: mm) (With ribs) 920.5 82.50.3 4-o4.30.3 Mounting hole 250.5 (4) (4) 82.50.3 920.5 Lead wire AWG24 UL 1007 +50 300 0 (10) Rotating direction 294 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.30 9WP0924F401 With pulse sensor Airflow direction 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 40 27.6 V 30 24 V 12 V 20 10 0 0.5 0 10 20 1.0 30 Airflow 1.5 40 50 (m3/min) 60 (CFM) Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side 90.5 4-o4.5 4-o4.5 o1 DC 82.50.3 Options Finger guards Model no.: 109-099E, 109-099H, 109-099C page: p. 532 Resin finger guards page: p. 539 Model no.: 109-1001G 295 Splash Proof Fan 92 mm sq. 82.50.3 90.5 82.50.3 90.5 o9 82.50.3 2 02 90.5 Outlet side Splash Proof Fan IP54 92x92x25 mm San Ace 92WS 9WS type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 150 g Ingress protection ................................. IP54 Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9WS0912H401 9WS0912F401 9WS0912M401 9WS0912L401 9WS0924H401 9WS0924F401 9WS0924M401 9WS0924L401 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.17 0.13 0.1 0.06 0.1 0.07 0.06 0.05 2.04 1.56 1.2 0.72 2.4 1.68 1.44 1.2 2850 2450 2100 1700 2850 2450 2100 1700 1.38 1.18 1.01 0.8 1.38 1.18 1.01 0.8 48.7 41.7 35.7 28.2 48.7 41.7 35.7 28.2 45.1 32.3 23.5 16.7 45.1 32.3 23.5 16.7 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 33 30 27 23 33 30 27 23 -20 to +70 40000/60C 0.181 0.13 0.094 0.067 0.181 0.13 0.094 0.067 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 581. Lock sensor Airflow - Static Pressure Characteristics 9WS0912H401 9WS0912F401 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.15 0.10 0.05 0 50 13.8 V 40 12 V 30 10.2 V 20 10 0 0.5 0 296 (inch H2O) (Pa) 1.0 20 40 Airflow 1.5 2.0 60 (m3/min) 80 (CFM) 0.15 50 0.14 13.8 V 40 12 V 30 0.10 10.2 V 20 0.05 0 0.12 Static pressure 0.20 0.20 With pulse sensor Operating voltage range (inch H2O) (Pa) 60 Static pressure Static pressure 0.25 9WS0912M401 With pulse sensor Operating voltage range 10 13.8 V 30 0.10 0.08 12 V 20 0.06 0.04 10.2 V 10 0.02 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) 60 (CFM) 0 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) Airflow - Static Pressure Characteristics 9WS0924H401 Operating voltage range Operating voltage range 0.08 20 0.06 15 0.04 10 0.02 5 0 0 Static pressure Static pressure 13.8 V 12 V 10.2 V 10 9WS0924M401 20 30 Airflow 40 30 20.4 V 20 10 0 0.5 1.0 20 1.5 40 Airflow 2.0 60 (m3/min) 80 (CFM) 27.6 V 40 24 V 30 0.10 20.4 V 20 0.05 0 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) 60 (CFM) With pulse sensor Operating voltage range 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 27.6 V 27.6 V 30 Static pressure Static pressure 24 V 0.15 50 (inch H2O) (Pa) 0.10 24 V 20 0.06 20.4 V 10 0.02 0 40 9WS0924L401 With pulse sensor 0.14 0.04 0.05 27.6 V 0 (inch H2O) (Pa) 0.08 0.10 0.20 50 (CFM) Operating voltage range 0.12 0.15 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 0.20 (inch H2O) (Pa) 60 Static pressure 0.25 25 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.10 9WS0924F401 With pulse sensor DC With pulse sensor 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 24 V 20.4 V 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 (CFM) 10 20 30 Airflow 40 (CFM) Dimensions (unit: mm) Lead wire AWG24 UL 1007 82.50.3 920.5 4-o4.30.3 Mounting hole +30 300 0 (10) 82.50.3 920.5 Rotating direction (4) (4) 250.5 Airflow direction 297 Splash Proof Fan 92 mm sq. 9WS0912L401 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 82.50.3 89 02 o1 82.50.3 89 Options Finger guards Model no.: 109-099E, 109-099H, 109-099C 298 page: p. 532 Resin finger guards Model no.: 109-1001G page: p. 539 Splash Proof Fan IP68 92x92x38 mm General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 92 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 300 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9WL0912P1H001 12 10.2 to 13.2 24 20.4 to 26.4 48 40.8 to 52.8 9WL0912P1F001 9WL0924P1H001 9WL0924P1F001 9WL0948P1H601 9WL0948P1F601 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 20 100 20 100 20 100 20 100 20 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.9 0.13 0.95 0.1 0.95 0.07 0.5 0.06 0.48 0.05 0.24 0.05 22.8 1.56 11.4 1.2 22.8 1.68 12 1.44 23.04 2.4 11.52 2.4 9000 2700 7000 2000 9000 2700 7000 2000 9000 2700 7000 2000 3.7 1.11 2.9 0.83 3.7 1.11 2.9 0.83 3.7 1.11 2.9 0.83 130.6 39.1 102.4 29.3 130.6 39.1 102.4 29.3 130.6 39.1 102.4 29.3 430 48.0 263 26.3 430 48.0 263 26.3 430 48.0 263 26.3 [inchHO] 1.72 0.19 1.05 0.1 1.72 0.19 1.05 0.1 1.72 0.19 1.05 0.1 SPL Operating temperature Expected life [dB (A)] [C] [h] 61 30 55 22 61 30 55 22 61 30 55 22 -20 to +70 100000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0912P1H001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.5 1.0 0.5 0 400 PWM duty cycle PWM 100% 300 200 100 0 20% 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow (min-1) PWM duty cycle 100% PWM100% 600 Static pressure Static pressure 2.0 500 (inch H2O) (Pa) 12 VDC DC12 V 600 PWM duty - Speed characteristics example 10000 1.5 1.0 0.5 0 8000 13.2 V/12 V 400 300 10.2 V 200 6000 4000 2000 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 9000 min-1 2.0 500 Fan speed PWM duty cycle 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 0 DC San Ace 92W 9WL type 100 (%) PWM PWM duty cycle 299 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0912P1F001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 200 150 0 50 0 20% 1 2 3 4 5 0.75 150 0.50 0.25 0 (m3/min) 0 PWM duty cycle PWM 100% 200 0 20% 1 2 3 4 5 1.5 1.0 0.5 0 (m3/min) 9WL0924P1F001 26.4 V/24 V 400 300 20.4 V 200 0 1 Static pressure Static pressure 20% 1 2 3 4 5 0.75 0.25 0 (m3/min) 9WL0948P1H601 PWM duty cycle PWM 100% 200 20% 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) 300 PWM duty - Speed characteristics example (min-1) 10000 20.4 V 100 7000 min-1 6000 4000 2000 50 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8000 26.4 V/24 V 200 1 2 3 4 5 0 (m3/min) 100 (%) PWM PWM duty cycle Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 600 300 0 100 (%) PWM PWM duty cycle Airflow Static pressure Static pressure 0 0 (m3/min) PWM duty cycle 100% PWM100% (inch H2O) (Pa) 48 VDC DC48 V 600 100 5 Operating voltage range (inch H2O) (Pa) 0.5 4000 With pulse sensor with PWM control function PWM duty cycle 1.0 4 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 400 3 150 0.50 0 20 40 60 80 100 120 140 160 180 (CFM) 1.5 2 1.00 250 100 2.0 500 6000 2000 100 300 PWM duty cycle PWM 100% 200 0 10000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 9000 min-1 (inch H2O) (Pa) 150 0 (min-1) Airflow 24 VDC DC24 V 300 50 PWM duty - Speed characteristics example Operating voltage range (inch H2O) (Pa) 0.25 100 (%) PWM PWM duty cycle With pulse sensor with PWM control function PWM duty cycle 0.50 0 (m3/min) 8000 Airflow 0.75 5 0 20 40 60 80 100 120 140 160 180 (CFM) 0 20 40 60 80 100 120 140 160 180 (CFM) 1.00 250 4 2.0 500 300 100 3 PWM duty cycle 100% PWM100% 600 Static pressure Static pressure 0.5 (inch H2O) (Pa) 24 VDC DC24 V 600 1.0 2 Operating voltage range (inch H2O) (Pa) 400 4000 With pulse sensor with PWM control function PWM duty cycle 1.5 1 Airflow Airflow 2.0 500 0 7000 min-1 6000 2000 50 0 20 40 60 80 100 120 140 160 180 (CFM) 0 20 40 60 80 100 120 140 160 180 (CFM) 9WL0924P1H001 10.2 V 100 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8000 13.2 V/12 V 200 Fan speed 0.25 100 1.00 250 Fan speed 0.50 10000 10000 1.5 1.0 0.5 0 8000 52.8 V/48 V 400 300 40.8 V 200 6000 4000 2000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 9000 min-1 2.0 500 Fan speed 0.75 100% (min-1) PWM duty cycle 100% PWM100% 300 PWM duty cycle PWM Static pressure Static pressure 300 1.00 250 (inch H2O) (Pa) 12 VDC DC12 V PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL0948P1F601 With pulse sensor with PWM control function Operating voltage range 200 150 0.50 0.25 0 100 50 0 20% 1 2 3 4 10000 1.00 250 Static pressure Static pressure 0.75 300 PWM duty cycle PWM 100% (min-1) PWM duty cycle 100% PWM100% 5 0.75 150 0.50 0.25 0 (m3/min) 8000 52.8 V/48 V 200 40.8 V 100 0 1 2 3 4 5 4000 0 (m3/min) 100 (%) PWM PWM duty cycle Airflow Airflow 7000 min-1 6000 2000 50 0 20 40 60 80 100 120 140 160 180 (CFM) 0 20 40 60 80 100 120 140 160 180 (CFM) Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 DC 300 1.00 250 (inch H2O) (Pa) 48 VDC DC48 V Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example Splash Proof Fan 92 mm sq. PWM duty cycle Dimensions (unit: mm) 8-o4.30.3 Mounting hole +30 300 0 920.5 82.50.3 (10) Lead wire AWG 26 UL 1430 40.3 82.50.3 920.5 40.3 380.5 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 82.50.3 82.50.3 4-o4.5 03 08 o1 90.5 82.50.3 o1 82.50.3 90.5 4-o4.5 90.5 90.5 Options Finger guards Model no.: 109-099E, 109-099H, 109-099C page: p. 532 Resin finger guards page: p. 539 Model no.: 109-1001G 301 Splash Proof Fan IP68 92x92x38 mm San Ace 92W 9WV type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 265 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9WV0924P1H001 24 20.4 to 26.4 9WV0948P1H001 48 40.8 to 52.8 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.6 0.16 0.82 0.14 38.4 3.84 39.4 6.7 8500 3000 8500 4000 5.05 1.78 5.05 2.37 178 62.9 178 83.7 385 47.9 385 85.2 [inchHO] 1.55 0.19 1.55 0.34 SPL Operating temperature Expected life [dB (A)] [C] [h] 64 38 64 45 -20 to +60 30000/60C -20 to +70 * PWM frequency: 25 kHz The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 581. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WV0924P1H001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.6 400 PWM PWM duty cycle 100% 1.4 350 1.2 300 1.0 250 60% 0.8 200 0.6 150 0.4 100 0.2 0 50 0 0 20% 1 2 50 3 100 4 150 Airflow 5 6 (m /min) 200 (CFM) 26.4 V 1.4 350 24 V 1.2 300 20.4 V 1.0 250 0.8 200 0.6 150 0.4 100 0.2 3 (min-1) PWM duty cycle 100% PWM100% 1.8 450 Static pressure Static pressure 1.6 400 302 (inch H2O) (Pa) 24 VDC DC24 V 1.8 450 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 50 0 0 1 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8500 min-1 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) 48 VDC DC48 V PWM duty cycle PWM 100% 50% 0% 0 0 1 2 50 3 100 4 5 150 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 6 (m /min) 3 200 Airflow 1.8 9000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 52.8 V 8500 min-1 7000 48 V 40.8 V 6000 5000 4000 4000 min-1 3000 2000 1000 0 1 2 50 0 (CFM) (min-1) PWM duty cycle 100% PWM100% DC 1.8 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Splash Proof Fan 92 mm sq. 9WV0948P1H001 3 100 4 5 150 6 (m3/min) 200 Airflow 0 100 (%) PWM duty cycle PWM (CFM) Dimensions (unit: mm) 4-o4.30.3 Mounting hole Lead wire UL 1430 82.50.3 920.5 AWG24 300 +30 0 (10) (4) 82.50.3 (4) 380.5 920.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 82.50.3 82.50.3 4-o4.5 08 03 o1 82.50.3 90.5 82.50.3 o1 90.5 4-o4.5 90.5 90.5 Options Finger guards Model no.: 109-099E, 109-099H, 109-099C page: p. 532 Resin finger guards page: p. 539 Model no.: 109-1001G 303 Splash Proof Fan IP68 120x120x38 mm San Ace 120W 9WV type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 440 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9WV1212P1J001 9WV1224P1J601 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 9WV1224P1H001** 9WV1248P1J001 * PWM frequency: 25 kHz PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 0 100 0 100 100 0 3 0.2 1.5 0.12 0.8 0.65 0.06 Max. airflow Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 36 2.4 36 2.88 19.2 31.2 2.88 6400 1500 6400 1500 5200 6400 1500 6.35 1.49 6.35 1.49 5.16 6.35 1.49 224.0 52.6 224.0 52.6 182 224.0 52.6 360 19.8 360 26.1 237 360 26.1 [inchHO] 1.45 0.08 1.45 0.105 0.95 1.45 0.105 SPL Operating temperature Expected life [dB (A)] [C] [h] 64 33 64 33 58 64 33 -20 to +70 60000/60C ** Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 581. Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) DC12 V V 12DC12 VDC 1.81.8 450 450 (inch H2O) (Pa) (inch H2O) (Pa) 1.81.8 450 450 1.61.6 400 400 1.41.4 350 350 PWM PWM duty cycle PWM 100% 100% 1.21.2 300 300 0.80.8 200 200 0.60.6 150 150 50% 50% 0.40.4 100 100 0.20.2 5050 00 0% 0% 3 3 /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8(m(m /min) (CFM) (CFM) 0 0 5050100 100150 150200 200250 250300 300 Airflow 304 1.21.2 300 300 1.01.0 250 250 1.41.4 350 350 Static pressure Static pressure 1.61.6 400 400 1.01.0 250 250 (min-1) PWM duty cycle 100% PWM100% PWM100% 7000 13.8 VV 13.8 1212 VV 10.2 VV 10.2 0.80.8 200 200 0.60.6 150 150 0.40.4 100 100 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6400 min-1 6000 5000 4000 3000 2000 1500 min-1 1000 0.20.2 5050 00 PWM duty - Speed characteristics example Fan speed 9WV1212P1J001 3 3 /min) 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 (m /min) 8 (m (CFM) (CFM) 0 0 5050100 100150 150200 200250 250300 300 Airflow 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WV1224P1J601 With pulse sensor with PWM control function 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 1 2 3 4 5 6 7 8 (m3/min) 0 50 100 150 200 250 300 (CFM) PWM duty cycle PWM 100% 50% 0% 350 24 V 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (inch (inch H2O) H2O) (Pa) (Pa) 1.41.4 350 350 1.21.2 300 300 PWM duty cycle PWM PWM 100% 100% 1.01.0 250 250 200 0.80.8 200 Static pressure 1.21.2 300 300 1.01.0 250 250 20.4 V 1 2 3 4 5 6 7 8 50 100 150 200 250 300 3000 2000 Airflow 1500 min-1 100 (%) PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 7000 27.6V V 27.6 6000 2424V V 5000 20.4 20.4V V 0.40.4 100 100 0.40.4 100 100 50% 50% 0.20.2 5050 00 3 3 0 0 1 1 2 2 3 3 4 4 5 5 6 6(m(m /min) /min) Airflow Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5200 min-1 4000 3000 2000 1000 3 3 0 0 1 1 2 2 3 3 4 4 5 5 6 6(m(m /min) /min) 00 (CFM) 5050 100 100 150 150 200 200(CFM) 9WV1248P1J001 4000 0 (m3/min) 0.60.6 150 150 100 (%) 0 PWM duty cycle PWM (CFM) 5050 100 100 150 150 200 200(CFM) Airflow With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 48 VDC DC48 V 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 1 2 3 4 5 6 7 8 (m3/min) 0 50 100 150 200 250 300 (CFM) PWM duty cycle PWM 100% 50% 0% Airflow (inch H2O) (Pa) (min-1) PWM duty cycle 100% PWM100% 1.8 450 1.6 400 55.2 V 1.4 350 48 V 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM duty - Speed characteristics example 7000 40.8 V (m3/min) 50 100 150 200 250 300 Airflow 6400 min-1 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 0.20.2 5050 6400 min-1 5000 1000 200 0.80.8 200 0.60.6 150 150 Static pressure 1.4 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 24 VDC DC24 DC24 V V 1.41.4 350 350 Static pressure 27.6 V Operating voltage range (inch (inch H2O) H2O) (Pa) (Pa) Static pressure 400 7000 With pulse sensor with PWM control function PWM duty cycle 00 1.6 Airflow 9WV1224P1H001 00 450 0 (min-1) PWM duty cycle 100% PWM100% 1.8 DC (inch H2O) (Pa) 24 VDC DC24 V 1.8 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example (CFM) 0 1500 min-1 100 (%) PWM duty cycle PWM 305 Splash Proof Fan 120 mm sq. Operating voltage range Fan speed PWM duty cycle Dimensions (unit: mm) 8-o4.50.4 Mounting hole Lead wire 1201 104.80.5 AWG24 UL 3266 +30 300 0 (250) (10) 6.50.5 3.50.3 104.80.5 1201 Rotating direction 6.50.5 3.50.3 380.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 118 35 o1 118 27 o1 104.80.3 4-o4.5 104.80.3 104.80.3 Outlet side 118 4-o4.5 104.80.3 Inlet side 118 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H 306 Resin finger guards Model no.: 109-1000G page: p. 539 Splash Proof Fan IP55 120x120x38 mm General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 120 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 410 g Ingress protection ................................. IP55 Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9WG1212G101-E 9WG1212E101-E 9WG1212H101-E 9WG1212F101-E 9WG1212M101-E 9WG1224G101-E 9WG1224E101-E 9WG1224H101-E 9WG1224F101-E 9WG1224M101-E 9WG1248G101-E 9WG1248E101-E 9WG1248H101-E 9WG1248F101-E 9WG1248M101-E [V] 10.2 to 13.8 12 7 to 13.8 20.4 to 27.6 24 14 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.98 0.61 0.38 0.28 0.21 0.5 0.34 0.22 0.16 0.11 0.25 0.17 0.11 0.09 0.07 11.76 7.32 4.56 3.36 2.52 12 8.16 5.28 3.84 2.64 12 8.16 5.28 4.32 3.36 3600 3100 2600 2280 1950 3600 3100 2600 2280 1950 3600 3100 2600 2280 1950 3.88 3.34 2.8 2.45 2.1 3.88 3.34 2.8 2.45 2.1 3.88 3.34 2.8 2.45 2.1 137 118 99 87 74 137 118 99 87 74 137 118 99 87 74 135 100 70.4 54.2 39.6 135 100 70.4 54.2 39.6 135 100 70.4 54.2 39.6 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.542 0.402 0.283 0.218 0.159 0.542 0.402 0.283 0.218 0.159 0.542 0.402 0.283 0.218 0.159 [C] 49 46 39 36 32 49 46 39 36 32 49 46 39 36 32 [h] 80000/60C 100000/60C 80000/60C -20 to +70 100000/60C 80000/60C 100000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 9WG1212G101-E 9WG1212E101-E With pulse sensor Operating voltage range Operating voltage range 140 100 0.3 80 0.1 0 13.8 V 12 V 120 0.4 0.2 0.5 10.2 V 60 40 20 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 0.4 0.3 0.2 0.35 120 0.30 13.8 V 100 Static pressure 0.5 160 Static pressure Static pressure 0.6 (inch H2O) (Pa) 140 180 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.7 9WG1212H101-E With pulse sensor 12 V 80 10.2 V 60 40 60 0.20 50 0.15 40 0.10 20 0.05 0 0 0 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 13.8 V 70 0.25 0.1 1 90 80 12 V 7V 30 20 10 0 1 2 3 4 DC San Ace 120W 9WG type (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 307 Airflow - Static Pressure Characteristics 9WG1212F101-E 9WG1212M101-E With pulse sensor Operating voltage range Operating voltage range 0 20 10 0 1 2 3 4 (m /min) 3 0.10 50 12 V 40 7V 30 20 0.05 10 0 0 1 0 0 20 40 60 80 100 120 140 (CFM) 20 40 9WG1224H101-E With pulse sensor Operating voltage range 0.2 0.35 120 0.30 27.6 V 100 Static pressure Static pressure 0.3 24 V 80 20.4 V 60 40 0.1 20 0 0 1 2 50 9WG1224M101-E 3 4 100 5 150 Airflow 6 200 Static pressure Static pressure 0.6 27.6 V 24 V 14 V 30 20 10 0 0 1 20 9WG1248H101-E 2 40 60 Airflow 3 80 100 0.15 40 0.10 0.05 0 55.2 V 48 V 40.8 V 20 3 4 (m /min) 1 2 Airflow 20 0 80 0.2 0.30 55.2 V 48 V 40.8 V 1 2 50 3 100 4 5 150 Airflow 6 (m3/min) 200 0.10 3 4 (m3/min) 0 60 0.20 50 0.15 40 0.10 27.6 V 70 24 V 14 V 30 20 10 0 1 0.5 120 0.4 100 2 3 4 (m3/min) With pulse sensor 0.3 0.2 55.2 V 48 V 80 40.8 V 60 40 0.1 20 0 0 1 2 50 9WG1248M101-E With pulse sensor 3 4 100 5 150 Airflow 6 (m3/min) 200 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 70 70 55.2 V 48 V 40.8 V 30 20 10 0 (CFM) With pulse sensor 80 0 80 40 Airflow 90 (CFM) 90 0.15 6 (m3/min) 200 140 0 50 5 150 Airflow 20 0.20 4 (inch H2O) (Pa) 40 60 3 100 Operating voltage range 60 0.25 2 50 9WG1248E101-E With pulse sensor 140 0.3 1 0 20 40 60 80 100 120 140 (CFM) 160 100 0.05 10 0 20 40 60 80 100 120 140 (CFM) 308 2 180 0.4 0.35 30 0 40 0.25 0 3 (inch H2O) (Pa) Static pressure Static pressure 50 1 0 80 0.20 0 Operating voltage range 90 60 0.30 0.05 9WG1248F101-E With pulse sensor 70 60 0 10 (CFM) (inch H2O) (Pa) 0.25 14 V 20 120 0 (m3/min) Operating voltage range 0.30 24 V 30 0.5 0.1 0 0.35 27.6 V Operating voltage range 0.7 20.4 V Operating voltage range (inch H2O) (Pa) 40 0.2 0.35 9WG1248G101-E With pulse sensor 50 80 0 20 40 60 80 100 120 140 (CFM) 60 0.05 0.10 0.3 Airflow 70 0.10 40 (CFM) (inch H2O) (Pa) 0.15 0.15 0 (m3/min) Operating voltage range 0.20 50 100 (inch H2O) (Pa) 70 60 0.4 27.6 V 24 V 9WG1224F101-E With pulse sensor 80 0.20 140 (CFM) 90 0.25 0.05 0 0.25 80 100 (m /min) (inch H2O) (Pa) 140 0.4 3 Operating voltage range (inch H2O) (Pa) 0.5 60 Airflow Airflow 9WG1224E101-E 2 160 120 0 3 180 0.5 0.1 Static pressure 0.05 7V 30 0.15 0.6 13.8 V Static pressure 0.15 40 12 V 0.20 0.7 60 Static pressure 60 50 0.10 13.8 V 70 0.20 0.25 Static pressure 0.25 80 Static pressure Static pressure 0.30 (inch H2O) (Pa) 70 90 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.35 9WG1224G101-E With pulse sensor 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0.25 60 0.20 50 0.15 0.10 55.2 V 48 V 40 40.8 V 30 20 0.05 10 0 0 1 0 20 40 2 60 Airflow 3 80 100 (m3/min) (CFM) Dimensions (unit: mm) 8-o4.30.3 Mounting hole (10) 1190.8 104.80.3 (250) +30 300 0 DC Lead wire AWG24 UL 1007 Rotating direction 6.50.3 3.50.3 380.5 Splash Proof Fan 120 mm sq. 6.50.3 3.50.3 104.80.3 1190.8 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 4-o4.5 o1 117 104.80.3 117 30 27 o1 4-o4.5 104.80.3 104.80.3 117 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin finger guards page: p. 539 Model no.: 109-1000G 309 Splash Proof Fan IP68 120x120x38 mm San Ace 120W 9WP type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 360 g Ingress protection ................................. IP68 Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9WP1212H101 9WP1212M101 9WP1212L101 9WP1224H101 9WP1224M101 9WP1248H101 9WP1248M101 [V] 7 to 13.8 12 10.2 to 13.8 24 14 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.38 0.21 0.14 0.22 0.11 0.11 0.07 4.56 2.52 1.68 5.28 2.64 5.28 3.36 2600 1950 1500 2600 1950 2600 1950 2.8 2.1 1.62 2.8 2.1 2.8 2.1 99 74.2 57.2 99 74.2 99 74.2 70.4 39.6 23.4 70.4 39.6 70.4 39.6 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 39 32 26 39 32 39 32 -20 to +70 40000/60C 0.283 0.159 0.094 0.283 0.159 0.283 0.159 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 580 to 581. Without sensor Lock sensor Airflow - Static Pressure Characteristics 9WP1212H101 9WP1212M101 With pulse sensor Operating voltage range 9WP1212L101 With pulse sensor Operating voltage range With pulse sensor Operating voltage range (inch H2O) (Pa) 0.40 80 60 0.20 50 0.15 40 0.05 0 13.8 V 70 0.25 0.10 70 12 V 7V 30 20 10 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 310 0.25 60 0.20 50 0.15 0.10 0.05 0 0.20 13.8 V Static pressure 0.30 (inch H2O) (Pa) (inch H2O) (Pa) 90 Static pressure Static pressure 0.35 12 V 40 10.2 V 30 7V 20 0.15 0 1 20 40 2 60 Airflow 3 80 100 (m3/min) (CFM) 40 13.8 V 30 12 V 0.10 20 0.05 10 0 50 0 10.2 V 10 0 0 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) Airflow - Static Pressure Characteristics 9WP1224H101 9WP1224M101 With pulse sensor Operating voltage range 9WP1248H101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 27.6 V 70 0.25 60 0.20 50 0.15 40 24 V 14 V 30 0.10 20 0.05 10 0 0 1 2 3 4 (m /min) 3 60 0.20 50 0.15 0.10 Airflow 0.35 27.6 V 24 V 40 20.4 V 30 14 V 20 0.05 10 0 0 0 0 20 40 60 80 100 120 140 (CFM) 9WP1248M101 0.25 Static pressure 80 Static pressure Static pressure 70 0.30 20 2 40 60 Airflow 3 80 100 (m3/min) (CFM) 80 60 0.20 50 0.15 40 0.10 0 55.2 V 70 0.25 0.05 1 90 48 V 40.8 V DC 90 0.30 0.40 (inch H2O) (Pa) 30 20 10 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 70 0.25 60 0.20 50 0.15 0.10 0.05 0 55.2 V 40 48 V 30 40.8 V 20 10 0 0 1 20 40 2 60 Airflow 3 80 100 Dimensions (unit: mm) (m3/min) (CFM) (With ribs) 4-o4.30.3 Mounting hole (10) 1190.8 104.80.3 +30 300 0 Lead wire AWG24 UL 1007 104.80.3 1190.8 Rotating direction (5) (5) 380.5 Airflow direction 311 Splash Proof Fan 120 mm sq. 0.40 0.35 With pulse sensor Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 117 104.80.3 o1 117 117 4-o4.5 34 104.80.3 26 o1 104.80.3 4-o4.5 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H 312 Resin finger guards Model no.: 109-1000G page: p. 539 Splash Proof Fan IP68 140x140x38 mm General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air Splash Proof Fan 140 mm sq. at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 740 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9WL1412P1A001 9WL1412P1H001 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 9WL1412P1M001 9WL1424P1A001 9WL1424P1H001 9WL1424P1M001 9WL1448P1A001 9WL1448P1H001 9WL1448P1M001 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.72 0.27 1.7 0.27 0.6 0.16 1.86 0.17 0.85 0.16 0.3 0.11 0.92 0.11 0.42 0.11 0.15 0.09 44.64 3.24 20.4 3.24 7.2 1.92 44.64 4.08 20.4 3.84 7.2 2.64 44.16 5.28 20.16 5.28 7.2 4.32 6900 2300 5200 2300 3300 1300 6900 2300 5200 2300 3300 1300 6900 2300 5200 2300 3300 1300 8.0 2.66 6.0 2.66 3.7 1.45 8.0 2.66 6.0 2.66 3.7 1.45 8.0 2.66 6.0 2.66 3.7 1.45 282 93 212 93 130 51 282 93 212 93 130 51 282 93 212 93 130 51 516 80 300 80 170 26 516 80 300 80 170 26 516 80 300 80 170 26 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 68 39 62 39 46 29 68 39 62 39 46 29 68 39 62 39 46 29 -20 to +70 100000/60C 2.07 0.32 1.2 0.32 0.68 0.1 2.07 0.32 1.2 0.32 0.68 0.1 2.07 0.32 1.2 0.32 0.68 0.1 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 579 to 580. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Model no. 9WL1448L1001 Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 48 40.8 to 55.2 0.11 5.3 2300 2.6 91.9 80 [inchHO] 0.32 SPL DC San Ace 140W 9WL type Operating temperature Expected life [dB (A)] [C] [h] 39 -20 to +70 100000/60C The following sensor and control options are available for selection. Available for all models. Without sensor 313 Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL1412P1A001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 50% 20% 100 0 0 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 Static pressure 8000 13.8 V 6000 1.0 250 0.8 200 10.2 V 0.6 150 4000 3000 0 0 2 3 4 5 6 7 (m3/min) 0 100 150 200 250 (CFM) Airflow 0.4 100 (inch H2O) (Pa) 12 VDC DC12 V 1.2 300 PWM duty cycle PWM 100% 50% 20% 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0.8 200 0.6 150 0.2 0 (m3/min) 9WL1424P1A001 0 (m3/min) 100 PWM PWM duty cycle Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 4000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 3500 3300 min-1 3000 13.8 V/12 V 10.2 V 2500 2000 1500 1000 50 500 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0 (m3/min) 100 (%) PWM PWM duty cycle Airflow (inch H2O) (Pa) 24 VDC DC24 V 700 PWM duty cycle PWM 100% Static pressure 2.5 600 400 300 0 7 Operating voltage range (inch H2O) (Pa) 0 6 With pulse sensor with PWM control function PWM duty cycle 100 5 0 20 40 60 80 100 120 140 160 (CFM) Airflow 200 4 0.4 100 0 20 40 60 80 100 120 140 160 (CFM) 2.0 500 3 100 150 200 250 (CFM) 1.0 250 50 600 2 Operating voltage range Static pressure 0.6 150 50 With pulse sensor with PWM control function 1.0 250 0.8 200 1 5200 min-1 5000 1000 50 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 12 V 1.2 300 0 1.2 300 Static pressure (min-1) PWM duty cycle 100% PWM100% 2000 1 100 (%) PWM duty - Speed characteristics example 50 (inch H2O) (Pa) Static pressure Airflow 0.2 9WL1412P1M001 314 0 PWM PWM duty cycle (CFM) 50 20% PWM duty cycle 0 50 100 150 200 250 300 0.4 100 0 0.5 1 2 3 4 5 6 7 8 9 (m3/min) 1.4 350 50% 0.4 100 1.0 0 1.6 400 0.8 200 1.5 3000 1000 (inch H2O) (Pa) 1.0 250 0.6 150 4000 2000 100 Operating voltage range PWM duty cycle PWM 100% 1.2 300 0 200 0 (CFM) 12 VDC DC12 V 1.4 350 0.2 300 5000 With pulse sensor with PWM control function (inch H2O) (Pa) Static pressure 0 (m3/min) PWM duty cycle 0 0.5 10.2 V Airflow 9WL1412P1H001 0.2 1.0 400 Fan speed 200 1.5 6900 min-1 6000 Fan speed 0 300 2.0 500 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 7000 12 V 50% 20% 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 Airflow (m3/min) (CFM) 2.0 500 1.5 1.0 0.5 0 400 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 27.6 V 7000 24 V 20.4 V 300 200 0 6900 min-1 5000 4000 3000 2000 100 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 0.5 Static pressure Static pressure 1.0 400 8000 13.8 V 2.5 600 100% (min-1) PWM duty cycle 100% PWM100% 700 PWM duty cycle PWM 2.0 500 1.5 (inch H2O) (Pa) 12 VDC DC12 V 600 PWM duty - Speed characteristics example Fan speed PWM duty cycle 1000 1 2 3 4 5 6 7 8 9 (m3/min) 50 100 150 200 250 300 Airflow (CFM) 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL1424P1H001 With pulse sensor with PWM control function Operating voltage range 1.6 400 PWM duty cycle PWM 100% 1.0 250 0.8 200 50% 0.6 150 0.4 100 1000 0 0 0 1 2 50 3 4 5 6 7 (m3/min) 0 100 150 200 250 (CFM) Airflow (inch H2O) (Pa) 24 VDC DC24 V 50% 20% 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 9WL1448P1A001 Airflow PWM duty - Speed characteristics example (min-1) 4000 0.2 (inch H2O) (Pa) 700 20% 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 1.5 1.0 0.5 0 (m3/min) 8000 40.8 V 300 200 6000 5000 4000 3000 1000 1 2 3 4 5 6 7 8 9 (m3/min) 50 100 150 200 250 300 0 Static pressure 50% 0.4 100 (min-1) 8000 55.2 V 1.4 350 0.8 200 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.6 400 PWM duty cycle PWM 100% 1.0 250 0.8 200 40.8 V 0.6 150 6000 5000 3000 2000 0.2 50 1000 0 0 0 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 0 1 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) 5200 min-1 4000 0.4 100 20% Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 48 V 1.2 300 50 50 100 (%) PWM PWM duty cycle (CFM) Airflow (inch H2O) (Pa) 48 VDC DC48 V 1 6900 min-1 2000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 Operating voltage range 1.0 250 0 100 (%) With pulse sensor with PWM control function (inch H2O) (Pa) 0.6 150 (min-1) 48 V 400 0 (CFM) PWM duty cycle 1.2 300 1500 PWM duty - Speed characteristics example 55.2 V 2.0 500 Airflow 9WL1448P1H001 2000 PWM PWM duty cycle Fan speed Static pressure 50% 100 2500 0 (m3/min) PWM duty cycle 100% PWM100% 2.5 600 300 1.4 350 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Operating voltage range 400 200 3300 min-1 3000 500 Airflow PWM duty cycle PWM 100% 2.0 500 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 1000 50 0 20 40 60 80 100 120 140 160 (CFM) 48 VDC DC48 V 600 100 PWM PWM duty cycle With pulse sensor with PWM control function (inch H2O) (Pa) Static pressure 0 (m3/min) 0.4 100 0 (m3/min) PWM duty cycle Static pressure 7 27.6 V/24 V/20.4 V 0.6 150 Airflow 0 6 3500 0.8 200 0 20 40 60 80 100 120 140 160 (CFM) 0.2 5 Fan speed Static pressure Static pressure 100% 50 0 4 PWM duty cycle 100% PWM100% 1.2 300 PWM duty cycle PWM 0.6 150 0 3 100 150 200 250 (CFM) 1.0 250 0.8 200 0 2 50 Operating voltage range 1.0 250 0.4 100 1 With pulse sensor with PWM control function 1.2 300 0.5 3000 2000 (inch H2O) (Pa) 1.0 4000 50 PWM duty cycle 1.5 20.4 V 0.6 150 0.2 9WL1424P1M001 0 0.8 200 5200 min-1 5000 50 0 0.2 1.0 250 0 6000 0.4 100 20% Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 24 V 1.2 300 Fan speed 0.2 8000 27.6 V 1.4 350 Static pressure 1.2 300 (min-1) PWM duty cycle 100% PWM100% DC 1.4 350 Static pressure (inch H2O) (Pa) 24 VDC DC24 V 0 100 PWM duty cycle PWM Airflow 315 Splash Proof Fan 140 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL1448P1M001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 1.2 300 1.0 250 0.4 100 0.2 0 3500 PWM duty cycle PWM 100% 50% 50 20% 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0.8 200 0.6 150 0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 (m3/min) With pulse sensor Operating voltage range (inch H2O) (Pa) 0.5 120 Static pressure 0.4 100 0.3 0.2 0.1 0 40.8 V/48 V/55.2 V 80 60 40 20 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0 20 40 60 80 100 120 140 160 (m3/min) (CFM) Airflow Dimensions (unit: mm) 8-o4.50.3 Mounting hole 380.5 +30 300 0 1400.8 124.50.5 (10) Lead wire AWG 22 UL 3266 124.50.5 1400.8 Rotating direction 316 3300 min-1 2500 2000 1500 500 Airflow Airflow 3000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 1000 50 0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 160 (CFM) 9WL1448L1001 40.8 V 0.4 100 0.2 (m3/min) 55.2 V/48 V 0.6 150 4000 Fan speed 0.8 200 (min-1) PWM duty cycle 100% PWM100% 1.0 250 Static pressure Static pressure (inch H2O) (Pa) 48 VDC DC48 V 1.2 300 PWM duty - Speed characteristics example 40.2 60.4 40.2 60.4 Airflow direction 0 100 (%) PWM duty cycle PWM Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 124.50.3 124.50.3 4-o4.5 50 47 o1 Splash Proof Fan 140 mm sq. DC 124.50.3 138 124.50.3 o1 138 4-o4.5 138 138 Options Finger guards page: p. 533 Model no.: 109-719, 109-719H 317 Splash Proof Fan IP68 140x140x51 mm San Ace 140W 9WL type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 930 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9WL1412P5G001 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 9WL1412P5S001 9WL1424P5G001 9WL1424P5S001 9WL1448P5G001 9WL1448P5S001 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 5.16 0.31 1.83 0.31 2.58 0.16 0.91 0.16 1.29 0.12 0.45 0.12 62 3.72 22 3.72 62 3.84 22 3.84 62 5.76 22 5.76 7500 2300 5000 2300 7500 2300 5000 2300 7500 2300 5000 2300 9.0 2.75 6.0 2.75 9.0 2.75 6.0 2.75 9.0 2.75 6.0 2.75 318 97 212 97 318 97 212 97 318 97 212 97 655 80 295 80 655 80 295 80 655 80 295 80 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 69 38 57 38 69 38 57 38 69 38 57 38 -20 to +70 100000/60C 2.63 0.32 1.18 0.32 2.63 0.32 1.18 0.32 2.63 0.32 1.18 0.32 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The models listed below have pulse sensors. Model no. 9WL1412A5001 9WL1412H5001 9WL1424H5001 9WL1424M5001 9WL1448H5001 Rated voltage Operating voltage range Rated current Rated input [V] [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 2.61 1 0.55 0.23 0.31 31.4 12 13.2 5.52 14.9 5700 4100 4100 2600 4100 6.9 4.9 4.9 3.1 4.9 243.8 173.1 173.1 109.5 173.1 500 260 260 100 260 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 579 to 580. Lock sensor 318 Max. airflow [A] [inchHO] 2 1.04 1.04 0.4 1.04 SPL Operating temperature Expected life [dB (A)] [C] [h] 61 52 52 40 52 -20 to +70 100000/60C Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL1412P5G001 With pulse sensor with PWM control function Operating voltage range Static pressure 100% 2.0 500 0 50% 200 100 0 20% 1 2 3 4 5 6 7 8 9 10 1.5 400 300 1.0 200 0.5 100 0 (m3/min) 0 50 100 150 200 250 300 350 (CFM) 50% 0.4 100 20% 50 1 2 50 3 4 5 6 7 (m3/min) 100 150 200 0.5 0 PWM PWM duty cycle 100% 300 50% 200 0 20% 1 2 3 4 5 6 7 8 9 10 9WL1424P5S001 2000 1000 0 0 5 6 7 (m3/min) Airflow 3.5 900 800 3.0 700 2.5 600 (min-1) 8000 27.6 V 1.5 400 300 1.0 200 0.5 100 0 0.4 100 20% 50 2 7500 min-1 6000 20.4 V 2.0 500 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 24 V 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 9 10 1.8 450 50% 50 100 (%) PWM duty - Speed characteristics example 0 (m3/min) 100 (%) PWM PWM duty cycle Airflow PWM duty cycle PWM 100% 1 0 PWM PWM duty cycle (CFM) 0 50 100 150 200 250 300 350 (CFM) 3 4 5 6 100 150 200 Airflow 1.6 400 Static pressure Static pressure 4 PWM duty cycle 100% PWM100% (inch H2O) (Pa) 24 VDC DC24 V 0.8 200 0 3 100 150 200 Operating voltage range 1.2 300 0 2 50 With pulse sensor with PWM control function (inch H2O) (Pa) 0.6 150 3000 50 0 (m3/min) PWM duty cycle 1.0 250 4000 0.2 Airflow 0 10.2 V 5000 min-1 5000 0.4 100 0 50 100 150 200 250 300 350 (CFM) 0.2 6000 0.6 150 (inch H2O) (Pa) DC24 V 24 VDC 400 100 0.8 200 1 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 Operating voltage range Static pressure 1.0 8000 1.0 250 0 2.0 500 1.5 (min-1) With pulse sensor with PWM control function (inch H2O) (Pa) 700 PWM duty - Speed characteristics example 12 V 1.2 300 (CFM) PWM duty cycle 2.5 600 100 (%) PWM PWM duty cycle 13.8 V 1.4 350 Airflow 9WL1424P5G001 Static pressure 1.6 400 0.8 200 0 0 (m3/min) PWM duty cycle 100% PWM100% 1.8 450 Static pressure Static pressure (inch H2O) (Pa) PWM PWM duty cycle 100% 1.0 250 0 0 1 2 3 4 5 6 7 8 9 10 Airflow 12 VDC DC12 V 1.2 300 0 3000 1000 Operating voltage range (inch H2O) (Pa) 0.2 4000 With pulse sensor with PWM control function PWM duty cycle 0.6 150 5000 2000 0 50 100 150 200 250 300 350 (CFM) Airflow 9WL1412P5S001 10.2 V Fan speed 0.5 300 7500 min-1 6000 12 V 2.0 500 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 13.8 V Fan speed 1.0 400 8000 7 (m3/min) (CFM) PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% (min-1) 27.6 V 7000 8000 1.4 350 1.0 250 20.4 V 0.8 200 0.6 150 5000 3000 2000 0.2 50 1000 0 0 1 50 2 3 4 5 6 100 150 200 7 (m3/min) (CFM) 5000 min-1 4000 0.4 100 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 24 V 1.2 300 Fan speed 1.5 (min-1) PWM duty cycle 100% PWM100% 3.5 900 800 3.0 700 2.5 600 DC PWM duty cycle PWM 2.5 600 Static pressure (inch H2O) (Pa) 12 VDC DC12 V 700 0 100 (%) PWM duty cycle PWM Airflow 319 Splash Proof Fan 140 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WL1448P5G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM duty cycle PWM Static pressure 100% 2.0 500 1.0 0.5 0 400 300 50% 200 100 0 20% 1 2 3 4 5 6 7 8 9 10 (m3/min) 0 50% 0.4 100 20% 50 1 2 50 9WL1412A5001 3 4 5 6 7 (m3/min) 100 150 200 1.0 0.5 0 0.8 200 0.6 150 2000 1000 0 0 400 200 100 0 1 2 3 4 5 6 7 8 9 10 0 50 100 150 200 250 300 350 (m3/min) 9WL1424M5001 50 0 0 0 Static pressure Static pressure 1.2 300 12 V/13.8 V 1 2 50 3 4 40 20 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow With pulse sensor 1 2 3 Airflow 40.8 V/48 V/55.2 V 4 (m3/min) (CFM) 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 1 50 2 3 4 24 V/27.6 V 1.0 250 10.2 V 1.0 250 60 With pulse sensor Operating voltage range 1.2 300 20.4 V/24 V/27.6 V 0 20 40 60 80 100 120 140 320 9WL1424H5001 0.4 100 0.2 100 (%) 0 PWM duty cycle PWM (CFM) (inch H2O) (Pa) 80 0 7 (m3/min) Operating voltage range 0.5 120 0 6 With pulse sensor 9WL1448H5001 With pulse sensor (inch H2O) (Pa) 0.1 5 0.6 150 (CFM) Operating voltage range 0.2 4 Airflow 0.8 200 Airflow 0.3 3 100 150 200 (inch H2O) (Pa) 1.0 250 300 0.4 100 2 1.2 300 10.2 V 3000 50 (inch H2O) (Pa) 12 V 4000 0.2 50 5000 min-1 5000 0.4 100 1 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6000 Operating voltage range Static pressure Static pressure 1.5 8000 40.8 V 9WL1412H5001 With pulse sensor (min-1) 7000 1.0 250 0 13.8 V 2.0 500 PWM duty cycle PWM PWM duty - Speed characteristics example 48 V 1.2 300 Airflow (inch H2O) (Pa) 2.5 600 100 (%) 0 (m3/min) 55.2 V 1.4 350 (CFM) Operating voltage range 700 3000 PWM duty cycle 100% PWM100% 1.6 400 Static pressure Static pressure 0.8 200 0 1 2 3 4 5 6 7 8 9 10 1.8 450 PWM duty cycle PWM 100% 1.0 250 0 4000 1000 (inch H2O) (Pa) 48 VDC DC48 V 1.2 300 0 5000 2000 Operating voltage range (inch H2O) (Pa) 0.2 6000 40.8 V With pulse sensor with PWM control function PWM duty cycle 0.6 150 7500 min-1 Airflow Airflow 9WL1448P5S001 48 V/55.2 V 0 50 100 150 200 250 300 350 (CFM) 0 50 100 150 200 250 300 350 (CFM) Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 2.0 500 400 1.5 300 1.0 200 0.5 100 0 8000 Static pressure 1.5 (min-1) PWM duty cycle 100% PWM100% 3.5 900 800 3.0 700 2.5 600 Fan speed 2.5 600 Static pressure (inch H2O) (Pa) 48 VDC DC48 V 700 PWM duty - Speed characteristics example Fan speed PWM duty cycle 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 20.4 V 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 1 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow Dimensions (unit: mm) 510.5 8-o4.50.3 Mounting hole +30 300 0 (10) DC 1400.8 124.50.5 Rated voltage 12 V fan 12 V Lead wire AWG AWG20 20 UL UL 3266 3266 Splash Proof Fan 140 mm sq. Rated voltage 24 V/48 V fan 24 V/48 V Lead wire AWG AWG22 22 UL 3266 UL 3266 40.2 60.4 124.50.5 1400.8 Rotating direction 40.2 60.4 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side .5 o4 58 138 124.50.3 4- o1 o1 48 138 124.50.3 5 . o4 4- 124.50.3 124.50.3 Outlet side 138 138 Options Finger guards page: p. 533 Model no.: 109-719, 109-719H 321 Splash Proof Fan o IP68 172x150x51 mm San Ace 172W 9WG type Sidecut type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 860 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9WG5748P5G001 48 40.8 to 55.2 9WG5748P5H001 PWM duty cycle* [%] 100 0 100 0 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.91 0.21 1.62 0.21 140.0 10.1 78.0 10.1 8600 2000 6500 2000 15.46 3.59 11.6 3.59 546 127 410 127 1000 75.1 770 75.1 [inchHO] 4.02 0.3 3.09 0.3 SPL Operating temperature Expected life [dB (A)] [C] [h] 78 40 71 40 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 579. Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9WG5748P5G001 With pulse sensor with PWM control function Operating voltage range Static pressure 5.0 (inch H2O) (Pa) 5.0 DC48 V 48 VDC 1200 4.0 1000 3.0 2.0 1.0 0 PWM duty cycle PWM 800 100% 600 400 200 0 50% 3.0 2.0 1.0 5 10 15 20 (m3/min) Airflow 0 (min-1) PWM duty cycle 100% PWM100% 1200 9000 8600 min-1 7000 55.2 V 800 48 V 600 40.8 V 400 6000 5000 4000 3000 2000 200 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 4.0 1000 0% 0 100 200 300 400 500 600 700 (CFM) 322 Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 2000 min-1 1000 5 10 15 20 (m3/min) 0 100 200 300 400 500 600 700 (CFM) Airflow 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 800 700 PWM PWM duty cycle 600 2.0 100% 500 400 1.0 300 50% 200 2.0 0 7000 40.8 V/48 V/55.2 V 500 400 1.0 300 10 15 (m /min) 100 200 300 400 500 Airflow 6500 min-1 5000 4000 3000 1000 0 5 0 (CFM) 6000 2000 2000 min-1 200 0 3 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 8000 700 100 5 0 9000 800 600 0% 100 0 3.0 (min-1) PWM duty cycle 100% PWM100% 900 Static pressure Static pressure 3.0 (inch H2O) (Pa) 48 VDC DC48 V 900 DC (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Splash Proof Fan o172 mm 9WG5748P5H001 10 15 (m /min) 100 200 300 400 500 3 (CFM) 0 100 (%) PWM duty cycle PWM Airflow Dimensions (unit: mm) 8-o4.50.3 Mounting hole +30 300 0 1620.5 o1720.8 10 Lead wire AWG22 UL 1430 .5 55. 55 5 7.50.4 7.50.4 510.8 1500.8 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 8.5 o1 2- R4 .2 5 1620.5 o172 68 4-o4.5 55 5 .5 147 55. Options Finger guards page: p. 534 Model no.: 109-319J, 109-319E, 109-319H, 109-320 323 Splash Proof Fan o IP68 172x150x51 mm San Ace 172W 9WE type Sidecut type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 860 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WE5724K501 9WE5748K501 Rated speed Max. airflow [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 24 48 20.4 to 27.6 40.8 to 55.2 1.3 0.7 31.2 33.6 4100 4100 8.5 8.5 300 300 243 243 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 578. Lock sensor PWM control Airflow - Static Pressure Characteristics 9WE5724K501 9WE5748K501 With pulse sensor Operating voltage range 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 24 V 20.4 V 2 0 324 Static pressure Static pressure (inch H2O) (Pa) 300 1.0 With pulse sensor Operating voltage range (inch H2O) (Pa) 1.2 4 100 6 200 Airflow Max. static pressure [V] 8 300 10 (m3/min) 400 (CFM) 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 55.2 V 48 V 40.8 V 2 0 4 100 6 200 Airflow 8 300 10 (m3/min) 400 (CFM) [inchHO] 0.976 0.976 SPL [dB (A)] 60 60 Operating temperature Expected life [C] [h] -20 to +60 40000/60C 40000/60C Dimensions (unit: mm) 4-o4.50.3 Mounting hole (10) o1720.8 1620.5 +30 300 0 DC Lead wire AWG24 UL 1007 Rotating direction 7.50.4 Splash Proof Fan o172 mm 7.50.4 1500.8 510.8 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 2- R4 .25 1620.3 o1 68 148 8.5 2-o4.5 Options Finger guards page: p. 534 Model no.: 109-319E, 109-319H, 109-320 325 Splash Proof Fan o IP68 172x51 mm San Ace 172W 9WE type Round type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 890 g Ingress protection ................................. IP68 Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WE1724K501 [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 27.6 1.3 31.2 4100 8.5 300.1 243 Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 24 V 20.4 V 2 0 326 4 100 6 200 Airflow Max. static pressure [A] Available for all models. Without sensor 1.2 Max. airflow [V] The following sensor and control options are available for selection. 9WE1724K501 Rated speed [V] 8 300 10 (m3/min) 400 (CFM) [inchHO] 0.97 SPL Operating temperature Expected life [dB (A)] [C] [h] 55 -20 to + 60 40000/60C Dimensions (unit: mm) 8-o4.50.3 Mounting hole +30 300 0 o1720.8 1620.5 (10) DC Lead wire AWG24 UL 1007 7.50.4 Splash Proof Fan o172 mm 7.50.4 1620.5 510.8 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4- R4 .2 5 1620.3 o1 68 1620.3 8.5 4-o4.5 Options Finger guards page: p. 534 Model no.: 109-1066, 109-1068, 109-319E, 109-319H, 109-320 327 328 Splash Proof Centrifugal Fan Centrifugal fans of IP54 and IP56 waterproof capability. For more information on IP rating, refer to p. 553. Related product: Splash Proof Fan p. 267, Centrifugal Fan p. 431, Oil Proof Fan p. 335 Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 48 Impeller size P Voltage Type name 4 PWM control function H Thickness 01 Speed code DC Type name M Individual customer s spec (2 to 3 digits) Splash Proof Centrifugal Fan 9W1T 9W1T 9W2T Impeller size (mm) Voltage (V) G J M N P S o 175 o 133 o 100 o 150 o 221 o 225 24 24 48 48 Thickness (mm) 0 69 min. 1 35 Speed code H G S 4 25 etc. How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 329 Splash Proof Centrifugal Fan o IP54 100x25 mm San Ace 100W 9W1T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Control Brown Mass ...................................................... 160 g Ingress protection ................................. IP54 Specifications When the optional inlet nozzle (109-1080) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9W1TM48P4G01** 48 9W1TM48P4H01 36 to 60 PWM duty cycle* [%] Rated current Rated input Rated speed 100 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.36 0.22 0.04 17.28 10.56 1.92 7400 6400 2000 2.03 1.77 0.51 71.7 62.5 18.0 708 560 48 [inchHO] 2.84 2.25 0.19 SPL Operating temperature Expected life [dB (A)] [C] [h] 65 60 34 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz ** Fan does not rotate when PWM duty cycle is 0%. Max input of 9W1TM48P4G01: 22 W, 9W1TM48P4H01: 14 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9W1TM48P4G01 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 800 3.0 PWM PWM duty cycle 100% 2.5 600 2.0 500 1.5 400 300 1.0 200 0.5 100 0 50% 0 0.5 1.0 1.5 2.0 2.5 700 36 V 1.5 400 300 1.0 200 0.5 100 0 48 VDC DC48 V 0.5 400 0 50% 200 100 0% 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 330 1.0 1.5 2.0 2.5 4000 3000 100 (%) 0 (m3/min) PWM PWM duty cycle Airflow (inch H2O) (Pa) 2.5 PWM PWM duty cycle 100% 300 1.0 0.5 0 10 20 30 40 50 60 70 80 90 (CFM) Static pressure Static pressure 1.5 5000 1000 Operating voltage range (inch H2O) (Pa) 2.0 500 6000 With pulse sensor with PWM control function PWM duty cycle 600 7400 min-1 2000 Airflow 2.5 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 48 V 2.0 500 0 10 20 30 40 50 60 70 80 90 (CFM) 9W1TM48P4H01 8000 60 V 2.5 600 0 (m3/min) (min-1) PWM duty cycle 100% PWM100% 800 2.0 1.5 600 PWM duty - Speed characteristics example 0.5 0 8000 60 V 48 V 400 36 V 200 6400 min-1 6000 5000 4000 3000 2000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 500 300 1.0 (min-1) PWM duty cycle 100% PWM100% Fan speed 700 Static pressure Static pressure 3.5 48 VDC DC48 V Fan speed 3.5 3.0 PWM duty - Speed characteristics example 2000 min-1 1000 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) Rotating direction o 56 0. 3 Airflow direction 251 18.51 60 o721 (10) DC 8.50.5 +30 300 0 Airflow direction 50.51 Splash Proof Centrifugal Fan o100 mm o1001 o741 1 Lead wire AWG26 UL 1007 3-M4 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side o5 6 3-o4 0.5 20 1 4-o4 .5 o11 6.6 o106 0.5 0.5 120 .5 Inlet nozzle side 12 0 Reference Diagram for Mounting Finger guard (5) (1.15) Inlet nozzle (27) Fan Bolt length: 5 mm max. 5 mm Options Finger guards Model no.: 109-099E, 109-099H page: p. 532 Inlet nozzle page: p. 537 Model no.: 109-1080 331 Splash Proof Centrifugal Fan o IP54 133x91 mm San Ace 133W 9W1T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 720 g Ingress protection ................................. IP54 Specifications When the optional inlet nozzle (109-1069) is mounted. The models listed below have pulse sensors with PWM control function. [V] [V] PWM duty cycle* [%] 24 48 20.4 to 27.6 36 to 60 100 100 Rated voltage Operating voltage range Model no. 9W1TJ24P0H61 9W1TJ48P0H61 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.2 0.55 28.8 26.4 4150 4150 6.39 6.39 225 225 395 395 [inchHO] 1.59 1.59 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 61 61 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input is 45 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range PWM PWM duty cycle 100% 400 300 1.0 50% 200 0.5 0 100 1 0 0 2 3 4 5 6 7 1 0 2 3 4 5 6 7 (m /min) 50 100 150 200 250 (CFM) 50% 200 100 1 0 50 2000 0 100 (%) PWM duty cycle PWM 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 1.5 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 2.0 500 PWM PWM duty cycle 100% 0 3 Airflow (inch H2O) (Pa) 48 VDC DC48 V Static pressure Static pressure 332 0 3000 1000 100 Operating voltage range 1.0 0 0 4150 min-1 With pulse sensor with PWM control function 300 0.5 0.5 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 200 Airflow (inch H2O) (Pa) 400 20.4 to 27.6 VV 20.4VV27.6 400 300 (m3/min) PWM duty cycle 1.5 5000 1.0 50 100 150 200 250 (CFM) 9W1TJ48P0H61 2.0 500 1.5 (min-1) PWM duty cycle 100% PWM100% 2.0 500 Static pressure Static pressure 1.5 (inch H2O) (Pa) DC24 V 24 VDC 2.0 500 Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example 5000 48 V/60 V 400 4000 Fan speed 9W1TJ24P0H61 36 V 300 1.0 200 0.5 0 100 0 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 4150 min-1 3000 2000 1000 1 2 3 4 5 6 7 (m3/min) 50 100 150 200 250 (CFM) Airflow 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 911 46.81 Airflow direction +30 300 0 (10) 1 45 60.61 Lead wire AWG24 UL 1430 271 o1331 o92.81 4-M4 8 0.3 DC o5 Splash Proof Centrifugal Fan o133 mm o77.51 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side Inlet nozzle side o11 8 0 .5 o1080 4-o4.5 45 o580.5 .5 4-o4 .5 (2) Reference Diagram for Mounting (13) Fan Fan Finger guard Inlet nozzle (102) Inlet nozzle mm Bolt length: 66mm max. Options Finger guards Model no.: 109-1112 page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1069, 109-1069H 333 Splash Proof Centrifugal Fan o IP54 150x35 mm San Ace 150W 9W1T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Brown Control Mass ...................................................... 330 g Ingress protection ................................. IP54 Specifications When the optional inlet nozzle (109-1081) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 48 9W1TN48P1H01 36.0 to 55.2 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 0.32 Max. airflow [min-1] [W] 15.4 [m/min] 3800 3.83 [CFM] 135 Max. static pressure [Pa] 390 [inchHO] 1.57 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 59 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input is 22 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9W1TN48P1H01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.5 400 (inch H2O) (Pa) 48 VDCV DC48 PWM PWM duty cycle 100% 300 1.0 200 0.5 0 50% 100 0 1 2 3 4 5 (m3/min) 0 25 50 75 100 125 150 175 (CFM) Airflow 334 1.5 400 300 48 V 200 0 4000 36 V 0 3800 min-1 1 2 3 4 5 25 50 75 100 125 150 175 Airflow 3000 2000 1000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 55.2 V 1.0 0.5 (min-1) PWM duty cycle 100% PWM100% 2.0 500 Static pressure Static pressure 2.0 500 PWM duty - Speed characteristics example Fan speed PWM duty cycle (m3/min) (CFM) 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) Airflow direction 351 28.51 +30 300 0 1 45 Lead wire AWG24 UL 1061 (10) 8.51 . o1501 o1051 51.21 4-M4 DC o89. 4 o64 1 0. Airflow direction Splash Proof Centrifugal Fan o150 mm 3 Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side o1 2 o11 80. 5 7 0. 5 4 0.5 45 o64-o4.5 Inlet nozzle side 4-o4 .5 Fan (41) (7) (1) Reference Diagram for Mounting Inlet nozzle Finger guard Fan Inlet nozzle Bolt length:mm 4 to 6 mm. 4 mm6 Options Finger guards Model no.: 109-1104, 109-1104H page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1081, 109-1081H 335 Splash Proof Centrifugal Fan o IP56 175x69 mm San Ace 175W 9W2T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 980 g Ingress protection ................................. IP56 Specifications When the optional inlet nozzle (109-1073H) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 48 9W2TGA48P0G001 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 Max. airflow [A] [W] [min-1] [m/min] 3.85 0.08 184.8 3.84 5700 800 17.3 2.4 [CFM] Max. static pressure [Pa] [inchHO] 611 1100 4.42 84.7 21.7 0.087 SPL Operating temperature [dB (A)] [C] [h] -30 to +60 40000/60C (70000/40C) 80 38 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input is 330 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9W2TGA48P0G001 With pulse sensor with PWM control function Operating voltage range 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 PWM duty cycle PWM 100% 15% 5 10 15 20 0 100 200 300 400 500 600 700 Airflow 336 (inch H2O) (Pa) 48 VDC DC48 V Static pressure Static pressure (inch H2O) (Pa) (m3/min) (CFM) (min-1) PWM100% PWM duty cycle 100% 1200 4.5 4.0 1000 3.5 800 3.0 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 PWM duty - Speed characteristics example 6000 48 V/72 V Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 5700 min-1 5000 Fan speed PWM duty cycle 36 V 4000 3000 2000 1000 5 10 15 20 0 100 200 300 400 500 600 700 Airflow (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) +30 0 61.51 45 Airflow direction (10) Lead wire (70) 300 691 AWG 18 UL 1430 o100.81 o5 8 Airflow direction Splash Proof Centrifugal Fan o175 mm 0.3 DC o48.41 90 o1751 o1311 4-M4 Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side Inlet nozzle side 4-o o1 o14 58 8 0.5 4.5 .5 45 4-o4.5 o580.5 0 Reference Diagram for Mounting Inlet nozzle (14) (2) Finger guard Inlet nozzle Fan Fan Bolt length: 66mm mmmax. Options Finger guards Model no.: 109-722, 109-722H page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1073, 109-1073H 337 Splash Proof Centrifugal Fan o IP54 175x69 mm San Ace 175W 9W1T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 760 g Ingress protection ................................. IP54 Specifications When the optional inlet nozzle (109-1073) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 48 9W1TG48P0H61 36 to 60 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 0.65 Max. airflow [min-1] [W] 31.2 [m/min] 3100 9.0 [CFM] 318 Max. static pressure [Pa] 360 [inchHO] 1.44 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 64 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input is 60 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 400 300 1.0 200 0.5 0 50% 100 0 2 4 6 8 10 (m3/min) 0 50 100 150 200 250 300 350 (CFM) Airflow 338 1.5 36 V 300 200 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 3000 3100 min-1 2000 1000 100 0 4000 48 V/60 V 400 1.0 0.5 (min-1) PWM duty cycle 100% PWM100% 2.0 500 PWM PWM duty cycle 100% Static pressure Static pressure 2.0 500 1.5 (inch H2O) (Pa) 48 VDC DC48 V PWM duty - Speed characteristics example Fan speed 9W1TG48P0H61 2 4 6 8 10 (m3/min) 0 50 100 150 200 250 300 350 (CFM) Airflow 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 691 60.51 300 +30 0 1 Airflow direction 45 Lead wire (10) AWG24 UL 1430 DC o1751 o1311 46.81 271 o5 8 o77.51 Rotating direction 0.3 Airflow direction Splash Proof Centrifugal Fan o175 mm 4-M4 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side o1 58 0 .5 8 0.5 Inlet nozzle side 4-o 4.5 o14 45 4-o4.5 o580.5 Reference Diagram for Mounting (2) Inlet nozzle Fan (81) Inlet nozzle (14) Finger guard Fan Bolt length: 4 to 6 mm. 4 mm6 mm To prevent bolts from loosening, use plain washers and spring washers. Options Finger guards Model no.: 109-722, 109-722H page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1073, 109-1073H 339 Splash Proof Centrifugal Fan o IP56 221x71 mm San Ace 221W 9W2T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 1250 g Ingress protection ................................. IP56 Specifications When the optional inlet nozzle (109-1135H) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9W2TP24P0H001 16 to 36 48 9W2TP48P0S001 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 100 15 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.35 0.4 2.3 0.2 80.4 9.6 110.4 9.6 3050 1000 3400 1000 17.6 5.75 19.6 5.75 621 203 692 203 530 57.0 659 57.0 [inchHO] 2.13 0.23 2.65 0.23 SPL Operating temperature Expected life [dB (A)] [C] [h] 71.5 53.5 73.5 53.5 -25 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9W2TP24P0H001: 150 W, 9W2TP48P0S001: 210 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9W2TP24P0H001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 100% 2.0 1.5 400 1.0 200 15% 0.5 0 60% 0 0 10 400 15 20 600 25 800 Airflow 9W2TP48P0S001 0 0 0 340 3.0 100% Static pressure Static pressure 200 5 10 200 (inch H2O) (Pa) PWM PWM duty cycle 1.5 400 0.5 0 60% 15% 5 200 2000 1000 400 15 20 600 25 800 Airflow 0 (m3/min) 100 (%) PWM PWM duty cycle (CFM) Operating voltage range 2.0 1.0 200 0 (CFM) 48 VDC DC48 V 2.5 600 16 V 3050 min-1 3000 With pulse sensor with PWM control function (inch H2O) (Pa) 3.0 0 (m3/min) PWM duty cycle 800 400 0.5 5 200 24 V/36 V 2.0 1.0 5000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 2.5 600 1.5 (min-1) PWM duty cycle 100% PWM100% 800 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 800 5000 4000 2.0 36 V 1.5 400 1.0 200 400 15 600 Airflow 20 25 800 (m3/min) (CFM) 0 0 0 3400 min-1 3000 2000 1000 0.5 10 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 48 V/72 V 2.5 600 Fan speed 2.5 600 3.0 Static pressure Static pressure 3.0 (inch H2O) (Pa) 24 VDC DC24 V 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 5 200 10 400 15 600 Airflow 20 25 800 (m3/min) (CFM) 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) Airflow direction +30 0 (10) (70) 300 711 63.51 45 Lead wire AWG 18 UL 1430 o118.61 Splash Proof Centrifugal Fan o221 mm o5 Airflow direction DC 8 0.3 90 o2211 o1611 4-M4 Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet nozzle side 45 o2 Fan side 45 5 0. 4-o4.5 0.5 4-o 2 0 o2 45 4.5 o580.5 5 0. Reference Diagram for Mounting Finger guard (21) (2) Inlet nozzle Fan Bolt length: 66 mm mm max. Options Finger guards Model no.: 109-1138H page: p. 535 Inlet nozzle page: p. 537 Model no.: 109-1135H 341 Splash Proof Centrifugal Fan o IP56 225x99 mm San Ace 225W 9W2T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 1500 g Ingress protection ................................. IP56 Specifications When the optional inlet nozzle (109-1134H) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 48 9W2TS48P0S001 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.45 0.24 117.6 11.5 3000 1000 23.5 7.83 830 276 635 70.6 [inchHO] 2.55 0.28 SPL Operating temperature [dB (A)] [C] [h] -25 to +70 40000/60C (70000/40C) 72.0 52.5 Expected life * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input is 220 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9W2TS48P0S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 2.5 600 3.0 PWM PWM duty cycle 100% 2.0 1.5 400 1.0 200 0.5 0 0 0 342 (inch H2O) (Pa) 48 VDC DC48 V Static pressure Static pressure 3.0 800 60% 15% 5 200 10 400 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 800 4000 36 V 2.0 1.5 400 1.0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 48 V/72 V 2.5 600 Fan speed PWM duty cycle 3000 3000 min-1 2000 1000 200 0.5 15 600 Airflow 20 25 800 (m3/min) (CFM) 0 0 0 5 200 10 400 15 600 Airflow 20 25 800 (m3/min) (CFM) 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) 45 Airflow direction +30 0 (10) Lead wire AWG 18 UL 1430 (70) 300 991.5 90.41.5 DC 90 +2 o225 0 +2 o153 0 4-M4 Splash Proof Centrifugal Fan o225 mm 0. 3 o118.61 o5 8 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side 00 .5 0 10 o2 o2 Inlet nozzle side 4-o4 .5 0 .5 4-o4.5 45 o580 .5 Reference Diagram for Mounting Finger guard (29.5) (3.5) Inlet nozzle Fan Bolt length: 66 mm mm max. Options Finger guards Model no.: 109-1137H page: p. 535 Inlet nozzle page: p. 537 Model no.: 109-1134H 343 344 Oil Proof Fan Cooling fan capable of operating in an oil-mist environment. Related product: Splash Proof Fan p. 267, Splash Proof Centrifugal Fan p. 329 Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 12 24 H 1 01 Type name Frame size Voltage Speed code Frame thickness Sensor specifications 9WF Frame size (mm) 04 06 08 09 12 40 x 40 60 x 60 80 x 80 92 x 92 120 x 120 Voltage (V) 24 24 Speed code H Frame thickness (mm) 1 38 Sensor specifications Frame form 2 32 4 25 6 20 Oil Proof Fan Type name Frame form DC 9WF 7 15 01 02 D01 With a pulse sensor Without a sensor With a lock sensor Nil Ribbed frame How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 345 Oil Proof Fan 40x40x15 mm San Ace 40WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 35 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0424H701 [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 27.6 0.085 2.04 11300 0.195 6.9 80 Lock sensor Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range (inch H2O) (Pa) 120 Static pressure 0.4 100 0.2 24 V 60 20.4 V 40 0.1 0 20 0 0 346 27.6 V 80 0.1 2 4 0.2 6 Airflow Max. static pressure [A] Available for all models. Without sensor 0.3 Max. airflow [V] The following sensor and control options are available for selection. 9WF0424H701 Rated speed [V] 0.3 (m3/min) 8 10 (CFM) [inchHO] 0.32 SPL Operating temperature Expected life [dB (A)] [C] [h] 38 -20 to +70 40000/60C Dimensions (unit: mm) 4-o3.50.3 +1 40 0 hole Mounting 320.3 Lead wire AWG24 UL 1430 +1 15 0 (4) (4) 320.3 +1 40 0 +30 320 0 Rotating direction DC (10) Airflow direction Oil Proof Fan 40 mm sq. Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 39 (15) .5 38 320.3 4-o3.7 (15) Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 347 Oil Proof Fan 40x40x20 mm San Ace 40WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 50 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0424H601 9WF0424F601 24 Rated speed Max. airflow [A] [W] [min-1] [m/min] [CFM] [Pa] 20.4 to 27.6 0.11 0.076 2.64 1.82 13100 11000 0.26 0.22 9.2 7.77 90 62.8 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 9WF0424H601 9WF0424F601 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.4 120 100 27.6 V 80 24 V 20.4 V 60 40 0.3 0.2 0 0.1 2 4 0.2 6 Airflow 0.3 8 10 (m3/min) 12 (CFM) 100 27.6 V 80 24 V 60 20.4 V 40 0.1 20 0 348 Static pressure Static pressure 0.10 0.05 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 Max. static pressure [V] [V] 0 20 0 0.1 0 2 4 0.2 6 Airflow 0.3 (m3/min) 8 10 (CFM) [inchHO] 0.361 0.252 SPL Operating temperature Expected life [dB (A)] [C] [h] 42 37 -20 to +70 40000/60C Dimensions (unit: mm) +1 40 0 320.3 4-o3.50.3 Mounting hole 200.5 (4) (4) 320.3 +1 40 0 +30 320 0 (10) Lead wire AWG24 UL 1430 Rotating direction DC Airflow direction Oil Proof Fan 40 mm sq. Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 320.3 4-o3.7 39 320.3 (15) 38 .5 (15) Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 349 Oil Proof Fan 60x60x15 mm San Ace 60WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 62 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0624H701 [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 27.6 0.12 2.88 6800 0.52 18.3 95 Lock sensor Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 120 100 90 80 70 60 50 40 30 20 10 0 27.6 V 24 V 20.4 V 0.1 0.2 0.3 0.4 0.5 0.6 0 350 5 10 15 Airflow Max. static pressure [A] Available for all models. Without sensor 0.45 Max. airflow [V] The following sensor and control options are available for selection. 9WF0624H701 Rated speed [V] 20 (m3/min) 25 (CFM) [inchHO] 0.38 SPL Operating temperature Expected life [dB (A)] [C] [h] 44 -20 to +70 40000/60C Dimensions (unit: mm) +1 15 0 600.5 4-o4.30.3 Mounting hole (3.4) 500.3 (3.7) +50 300 0 500.3 600.5 Lead wire AWG24 UL 1430 DC (10) Oil Proof Fan 60 mm sq. Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 58 4-o4.5 500.3 3 58 500.3 o6 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H 351 Oil Proof Fan 60x60x20 mm San Ace 60WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 80 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0624H601 [W] [min-1] [m/min] [CFM] [Pa] 24 12 to 27.6 0.15 3.6 6600 0.69 24.3 114 Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range (inch H2O) (Pa) 0.64 160 Static pressure 0.56 140 0.48 120 0.32 80 0.24 60 0.16 40 0.08 20 0 0 0 352 27.6 V 24 V 12 V 0.2 0.4 0.6 0.8 5 10 15 20 25 30 Airflow Max. static pressure [A] Available for all models. Lock sensor 0.40 100 Max. airflow [V] The following sensor and control options are available for selection. 9WF0624H601 Rated speed [V] 1.0 (m3/min) (CFM) [inchHO] 0.45 SPL Operating temperature Expected life [dB (A)] [C] [h] 42 -20 to +70 40000/60C Dimensions (unit: mm) 60 +1 0 4-o4.50.3 Mounting hole 500.5 (4) 200.5 (4) Lead wire +1 60 0 500.5 AWG24 UL 1430 +50 300 0 DC (10) Rotating direction Oil Proof Fan 60 mm sq. Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H 353 Oil Proof Fan 60x60x25 mm San Ace 60WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 110 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0624H401 [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 27.6 0.15 3.6 6500 0.67 23.6 97 Lock sensor Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 120 110 100 90 80 70 60 50 40 30 20 10 0 27.6 V 24 V 20.4 V 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 354 5 10 15 20 Airflow Max. static pressure [A] Available for all models. Without sensor 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.50 0.05 0 Max. airflow [V] The following sensor and control options are available for selection. 9WF0624H401 Rated speed [V] 25 (m3/min) 30 (CFM) [inchHO] 0.38 SPL Operating temperature Expected life [dB (A)] [C] [h] 41 -20 to +70 40000/60C Dimensions (unit: mm) +1 60 0 4-o4.30.3 Mounting hole 500.3 250.5 (3) (3) Lead wire AWG24 UL 1430 500.3 +1 60 0 +50 300 0 (10) Rotating direction DC Airflow direction Oil Proof Fan 60 mm sq. Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H 355 Oil Proof Fan 80x80x25 mm San Ace 80WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 130 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0824S401 [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 27.6 0.16 3.84 4000 1.2 42.4 58 Lock sensor Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.25 80 70 0.20 50 0.15 40 0.10 0.05 0 27.6 V 60 24 V 20.4 V 30 20 10 0 0.5 0 356 10 20 1.0 30 Airflow Max. static pressure [A] Available for all models. Without sensor 0.30 Max. airflow [V] The following sensor and control options are available for selection. 9WF0824S401 Rated speed [V] 40 1.5 (m3/min) 50 (CFM) [inchHO] 0.23 SPL Operating temperature Expected life [dB (A)] [C] [h] 38 -20 to +70 40000/60C Dimensions (unit: mm) 4-o4.30.3 Mounting hole (3) 250.5 (3) Lead wire AWG24 UL 1430 +30 300 0 71.50.3 800.5 800.5 71.50.3 (10) DC Airflow direction Rotating direction Oil Proof Fan 80 mm sq. Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 78.5 71.50.3 o9 0 4-o4.5 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C 357 Oil Proof Fan 92x92x25 mm San Ace 92WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 120 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF0924H401 [A] [W] [min-1] [m/min] 24 20.4 to 27.6 0.13 3.12 3900 1.45 Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 578. Without sensor Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 0.3 80 27.6 V 70 24 V 60 0.2 20.4 V 50 40 0.1 30 20 10 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 0 358 10 20 30 40 50 Airflow Max. airflow [V] The following sensor and control options are available for selection. 9WF0924H401 Rated speed [V] (CFM) [CFM] 51.2 Max. static pressure [Pa] 66 [inchHO] 0.26 SPL Operating temperature Expected life [dB (A)] [C] [h] 42.5 -20 to +70 40000/60C Dimensions (unit: mm) 920.5 82.50.3 4-o4.30.3 Mounting hole (4) 250.5 (4) 920.5 82.50.3 Lead wire AWG24 UL 1430 +50 300 0 (10) Rotating direction DC Airflow direction Inlet side Outlet side 4- o4.5 02 82.50.3 90.5 o1 82.50.3 90.5 2 o9 4- o4.5 90.5 82.50.3 90.5 Oil Proof Fan 92 mm sq. Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C 359 Oil Proof Fan 92x92x32 mm San Ace 92WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 185 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input [V] 9WF0924S201 9WF0924H201 24 [V] [A] 20.4 to 27.6 0.5 0.35 Rated speed Max. airflow [min-1] [m/min] [CFM] [Pa] 12 8.4 7300 6500 2.8 2.45 98.9 86.5 255 200 The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 578 to 579. Without sensor Lock sensor Airflow - Static Pressure Characteristics 9WF0924S201 9WF0924H201 With pulse sensor Operating voltage range (inch H2O) (Pa) 1.0 0.8 0.6 0.4 0.2 0 325 300 275 250 225 200 175 150 125 100 75 50 25 27.6 V 24 V 20.4 V 0 0 360 Static pressure Static pressure 1.2 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 (m3/min) 20 40 60 80 100 120 Airflow (CFM) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Max. static pressure [W] 250 225 200 175 150 125 100 75 50 25 0 0 27.6 V 24 V 20.4 V 0.5 1.0 1.5 2.0 2.5 3.0 3.5 (m3/min) 20 40 60 80 100 120 Airflow (CFM) [inchHO] 1.02 0.8 SPL Operating temperature Expected life [dB (A)] [C] [h] 58 56 -20 to +70 40000/60C Dimensions (unit: mm) 920.5 82.50.3 4-o4.30.3 Mounting hole 320.5 (4) (4) Lead wire AWG24 UL 1430 920.5 82.50.3 +30 300 0 Rotating direction DC (10) Oil Proof Fan 92 mm sq. Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 82.50.3 Outlet side 82.50.3 4-o4.5 o1 90.5 90.5 82.50.3 03 o1 4-o4.5 08 82.50.3 Inlet side 90.5 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C 361 Oil Proof Fan 120x120x38 mm San Ace 120WF 9WF type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 355 g This fan can be used in environments with oil mist.* * Environment where cutting oil creates oil mist. Conduct a product evaluation with the type of oil to be used. Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9WF1224H101 [W] [min-1] [m/min] [CFM] [Pa] 24 20.4 to 27.6 0.32 7.68 3100 3.34 118 100 Lock sensor Airflow - Static Pressure Characteristics With pulse sensor Operating voltage range (inch H2O) (Pa) Static pressure 140 0.5 120 0.4 100 0.3 0.2 0.1 0 27.6 V 24 V 80 60 20.4 V 40 20 0 0 362 1 2 50 3 100 Max. static pressure [A] Available for all models. Without sensor 0.6 Max. airflow [V] The following sensor and control options are available for selection. 9WF1224H101 Rated speed [V] 4 150 Airflow 5 6 (m3/min) 200 (CFM) [inchHO] 0.4 SPL Operating temperature Expected life [dB (A)] [C] [h] 46 -20 to +70 40000/60C Dimensions (unit: mm) 4-o4.30.3 Mounting hole +30 300 0 104.80.3 Lead wire AWG24 UL 1430 (5) (5) 104.80.3 1190.8 Rotating direction DC 380.5 Airflow direction Oil Proof Fan 120 mm sq. 1190.8 (10) Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 117 104.80.3 117 o1 117 104.80.3 34 26 o1 4-o4.5 104.80.3 4-o4.5 104.80.3 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H 363 364 Long Life Fan Cooling fan with Max. 180,000 hours of expected life. Related product: Splash Proof Fan pp. 270, 273, 279, 289, 299 Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 9L 04 12 J 3 01 Type name Frame size Voltage Speed code Frame thickness Sensor specifications Fans with PWM control function 12 P 4 S Frame size Voltage PWM control function Frame thickness Speed code Type name 9CRL 9CRLA 9GL Frame size (mm) 04 06 08 9L 9LB 9LG 09 12 14 17 40 x 40 60 x 60 80 x 80 92 x 92 120 x 120 140 x 140 Voltage (V) 12 12 Speed code E Frame thickness (mm) 0 76 Sensor specifications 24 24 F 48 48 G H 1 38 3 28 001 Individual customer s spec DC 06 Type name (2 to 3 digits) Long Life Fan 9LG 57 o 172 o 172 x 150 (sidecut) etc. J etc. L M S 4 25 5 51 8 80 01 02 D01 With a pulse sensor Without a sensor With a lock sensor How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 365 Long Life Fan 40x40x28 mm San Ace 40L 9L type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 55 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. 9L0412J301 9L0412H301 9L0412M301 12 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 10.2 to 13.8 0.31 0.15 0.045 3.72 1.8 0.54 11700 8400 4000 0.52 0.37 0.16 18.4 13.1 5.65 206 106 24 [V] SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 48 40 19 -20 to +70 100000/60C 0.827 0.426 0.096 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on pp. 575 to 576. PWM control Airflow - Static Pressure Characteristics 9L0412J301 9L0412H301 With pulse sensor Operating voltage range Operating voltage range 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 13.8 V 12 V 10.2 V 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 366 5 10 15 Airflow 20 (CFM) 0.8 200 (inch H2O) (Pa) 0.6 150 0.15 Static pressure 1.0 Static pressure Static pressure 300 13.8 V 0.4 100 12 V 10.2 V 0.2 50 0 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 1.2 9L0412M301 With pulse sensor 0.1 0 0.2 5 0.3 10 Airflow 0.4 15 0.5 (m3/min) 20 (CFM) 40 30 13.8 V 0.10 12 V 20 0.05 0 10.2 V 10 0 0.05 0.10 0.15 0.20 0.25 (m3/min) 0 2 4 6 Airflow 8 (CFM) Dimensions (unit: mm) 400.3 320.3 8-o3.50.3 Mounting hole 40.3 280.5 40.3 320.3 400.3 +30 320 0 (10) Lead wire AWG26 UL 1007 Rotating direction Airflow direction DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 320.3 4-o3.7 40 (17.6) Long Life Fan 40 mm sq. 39 320.3 Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 367 Long Life Fan 60x60x25 mm San Ace 60L 9LG type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 100 g Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] 9LG0612P4S001 9LG0612P4J001 12 10.8 to 13.2 24 21.6 to 26.4 48 36 to 72 9LG0612P4H001 9LG0612P4M001 9LG0624P4S001 9LG0624P4J001 9LG0624P4H001 9LG0624P4M001 9LG0648P4S001 9LG0648P4J001 9LG0648P4H001 9LG0648P4M001 PWM duty cycle* [%] 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed [min-1] [A] [W] 0.67 0.06 0.39 0.03 0.17 0.03 0.09 0.03 0.34 0.03 0.19 0.02 0.08 0.02 0.04 0.01 0.18 0.02 0.1 0.02 0.06 0.02 0.04 0.02 8.04 0.72 4.68 0.36 2.04 0.36 1.08 0.36 8.16 0.72 4.56 0.48 1.92 0.48 0.96 0.24 8.64 0.96 4.8 0.96 2.88 0.96 1.92 0.96 11000 2900 8650 1150 6150 1350 4200 900 11000 2900 8650 2200 6150 1300 4200 800 11000 2900 8650 2100 6150 1000 4200 650 Max. airflow [CFM] [Pa] 1.4 0.36 1.1 0.13 0.78 0.17 0.53 0.11 1.4 0.36 1.1 0.28 0.78 0.16 0.53 0.1 1.4 0.36 1.1 0.26 0.78 0.12 0.53 0.08 49.4 12.7 38.8 4.8 27.5 6.0 18.7 3.8 49.4 12.7 38.8 9.8 27.5 5.6 18.7 3.5 49.4 12.7 38.8 9.1 27.5 4.2 18.7 2.8 300 20.8 182 3.3 97 4.7 45 2.0 300 20.8 182 12.0 97 4.3 45 1.6 305 20.8 182 10.7 97 2.5 45 1.0 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 576. Without sensor 368 Pulse sensor Max. static pressure [m/min] Lock sensor [inchHO] 1.204 0.083 0.73 0.013 0.389 0.018 0.18 0.008 1.204 0.083 0.73 0.048 0.389 0.017 0.18 0.006 1.224 0.083 0.73 0.042 0.389 0.01 0.18 0.004 SPL Operating temperature Expected life [dB (A)] [C] [h] 53 20 47 14 35 14 24 14 53 20 47 17 35 14 24 14 53 20 47 17 35 14 24 14 -20 to +70 180000/60C Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0612P4S001 With pulse sensor with PWM control function (inch H2O) (Pa) 12 VDC DC12 V 1.6 400 1.4 350 PWM PWM duty cycle 100% 1.2 300 1.0 250 Static pressure 0.8 200 0.6 150 50% 0.4 100 0 10 20 30 40 50 Airflow 9LG0612P4J001 (inch H2O) (Pa) 12 VDC DC12 V Static pressure Static pressure PWM PWM duty cycle 100% 0.6 150 50% 0.4 100 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 10 20 30 40 Airflow 9LG0612P4H001 50 Static pressure Static pressure 50% 0 0.2 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow 9LG0612P4M001 0.15 40 0.10 0.05 0 0 PWM PWM duty cycle 100% 20 50% 10 0.3 10 20 30 50 40 Airflow 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 (m3/min) Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8650 min-1 100 (%) PWM PWM duty cycle (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 13.2 V 75 12 V 0.2 50 0.1 25 0 0 10 0.25 10.8 V 0.2 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6150 min-1 100 (%) PWM duty cycle PWM (CFM) 15 20 Airflow 25 (CFM) 60 0.15 40 0 (min-1) 70 50 0.10 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 80 0.20 0.05 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0.4 100 0.30 30 0 0 (inch H2O) (Pa) 12 VDC DC12 V Static pressure Static pressure 50 50 0 70 0.20 0.2 Operating voltage range 80 60 (min-1) With pulse sensor with PWM control function (inch H2O) (Pa) 0.25 100 (%) PWM duty - Speed characteristics example 10.8 V 0.4 100 (CFM) PWM duty cycle 0.30 12 V 0.5 125 50 0 0.6 150 (inch H2O) (Pa) PWM PWM duty cycle 100% 75 0 13.2 V 0 12 VDC DC12 V 0.4 100 25 Airflow 0 11000 min-1 PWM duty cycle PWM (CFM) Operating voltage range 0.5 125 0.1 50 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.2 40 0.8 200 (CFM) PWM duty cycle 0.3 30 1.0 250 0.8 200 0 20 PWM duty cycle 100% PWM100% 1.2 300 1.0 250 0 10 Operating voltage range 1.2 300 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 With pulse sensor with PWM control function (inch H2O) (Pa) 50 50 0 (CFM) PWM duty cycle 0.2 0.4 100 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 10.8 V 0.6 150 0.2 50 12 V 0.8 200 Fan speed 0 1.0 250 Fan speed 0.2 13.2 V 1.2 300 Fan speed Static pressure 1.4 350 (min-1) PWM duty cycle 100% PWM100% 1.6 400 13.2 V 12 V 30 10.8 V 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 (CFM) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4200 min-1 100 (%) PWM duty cycle PWM 369 DC (inch H2O) (Pa) PWM duty - Speed characteristics example Long Life Fan 60 mm sq. Operating voltage range Fan speed PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0624P4S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 24 VDC DC24 V 1.6 400 PWM PWM duty cycle Static pressure 100% 1.0 250 0.8 200 0.6 150 50% 0.4 100 0 10 20 30 40 50 Airflow 9LG0624P4J001 (inch H2O) (Pa) 24 VDC DC24 V Static pressure Static pressure PWM PWM duty cycle 100% 0.6 150 50% 0.4 100 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0 10 20 30 40 Airflow 9LG0624P4H001 50 Static pressure Static pressure 50% 0 0 0 0.4 0.2 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow 9LG0624P4M001 370 0 PWM PWM duty cycle 100% 20 50% 10 0.3 10 20 30 50 40 Airflow 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 (m3/min) Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8650 min-1 100 (%) PWM PWM duty cycle (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 26.4 V 75 24 V 0.2 50 0.1 25 0 0 21.6 V 0.2 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6150 min-1 100 (%) PWM duty cycle PWM (CFM) 10 60 50 0.15 40 15 20 Airflow 25 (CFM) 0 (min-1) 70 0.20 0.10 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 80 0.25 0.05 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 5 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0.4 100 0.30 30 0 0 (inch H2O) (Pa) 24 VDC DC24 V Static pressure Static pressure 0.15 40 50 0 70 50 0.2 Operating voltage range 80 0.20 0 (min-1) With pulse sensor with PWM control function (inch H2O) (Pa) 60 100 (%) PWM duty - Speed characteristics example 21.6 V 0.4 100 (CFM) PWM duty cycle 0.25 24 V 0.5 125 50 25 0.6 150 (inch H2O) (Pa) PWM PWM duty cycle 100% 75 0.1 26.4 V 0 24 VDC DC24 V 0.4 100 0.05 Airflow 0 PWM duty cycle PWM (CFM) Operating voltage range 0.5 125 0.10 50 11000 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0.30 40 0.8 200 (CFM) PWM duty cycle 0.2 30 1.0 250 0.8 200 0.3 20 PWM duty cycle 100% PWM100% 1.2 300 1.0 250 0 10 Operating voltage range 1.2 300 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 50 50 0 (CFM) PWM duty cycle 0.2 0.4 100 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 21.6 V 0.6 150 0.2 50 24 V 0.8 200 Fan speed 0 1.0 250 Fan speed 0.2 26.4 V 1.2 300 Fan speed Static pressure 1.4 350 1.2 300 (min-1) PWM duty cycle 100% PWM100% 1.6 400 1.4 350 PWM duty - Speed characteristics example Fan speed PWM duty cycle 26.4 V 24 V 21.6 V 30 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 (CFM) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4200 min-1 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0648P4S001 With pulse sensor with PWM control function (inch H2O) (Pa) (inch H2O) (Pa) 48 VDC DC48 V 1.6 400 PWM PWM duty cycle 100% 1.0 250 0.8 200 0.6 150 0.4 100 0 10 20 30 40 Airflow 9LG0648P4J001 50 0 50% 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 20 10 30 Airflow 9LG0648P4H001 40 0.4 0.2 0.6 Static pressure Static pressure 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow 9LG0648P4M001 0.10 0.05 0 0.3 PWM PWM duty cycle 100% 30 50% 10 50 0.1 25 0 0 5 40 Airflow 0 8650 min-1 100 (%) PWM duty cycle PWM 50 (CFM) PWM duty - Speed characteristics example (min-1) 72 V 48 V 36 V 0.2 0.4 0.6 0.8 1.0 (m3/min) 5 10 15 20 25 30 35 Airflow 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6150 min-1 100 (%) PWM duty cycle PWM (CFM) 10 60 50 0.15 40 15 20 25 Airflow (CFM) 0 (min-1) 70 0.20 0.10 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 80 0.25 0.05 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 30 20 PWM duty cycle 100% PWM100% 75 0.2 0.30 20 10 (inch H2O) (Pa) DC48 V 48 VDC Static pressure Static pressure 0.15 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m3/min) 0.4 100 0 70 40 0 Operating voltage range 80 50 0 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.20 50 (CFM) PWM duty cycle 60 0.2 36 V 0.5 125 50% 0 0.4 100 (inch H2O) (Pa) PWM PWM duty cycle 100% 75 0.25 (min-1) 48 V/72 V 0.6 150 0 48 VDC DC48 V 0.5 125 0.30 PWM duty - Speed characteristics example Operating voltage range 0.4 100 100 (%) With pulse sensor with PWM control function (inch H2O) (Pa) 0 Airflow 0 11000 min-1 PWM duty cycle PWM (CFM) 0.8 200 50 (CFM) PWM duty cycle 0 50 Fan speed 0 25 40 Fan speed Static pressure Static pressure 0.4 100 0.1 30 PWM100% PWM duty cycle 100% 1.2 300 PWM PWM duty cycle 100% 0.6 150 50 20 1.0 250 0.8 200 0.2 10 (inch H2O) (Pa) 48 VDC DC48 V 1.0 250 0.3 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) Operating voltage range 1.2 300 0 50 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0 0.4 100 (CFM) PWM duty cycle 50 36 V 0.6 150 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 (m3/min) 48 V/72 V 0.8 200 0.2 50 0.2 1.0 250 Fan speed 0 50% 1.2 300 Fan speed Static pressure Static pressure 1.4 350 1.2 300 0.2 (min-1) PWM duty cycle 100% PWM100% 1.6 400 1.4 350 PWM duty - Speed characteristics example 72 V 48 V 30 36 V 20 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min) 0 5 10 15 20 Airflow 25 (CFM) 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 4200 min-1 100 (%) PWM duty cycle PWM 371 DC Operating voltage range Long Life Fan 60 mm sq. PWM duty cycle Dimensions (unit: mm) +50 300 0 500.3 600.5 8-o4.30.3 Mounting hole (10) Lead wire 500.3 600.5 40.3 AWG26 UL 1430 40.3 250.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 29.7 59 29.7 500.3 62 .7 4-o4.5 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 372 Resin finger guards page: p. 539 Long Life Fan 60x60x76 mm San Ace 60L 9CRLA type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 310 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRLA0612P0G001 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 20 SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 3.0 0.4 36.0 4.8 16500 17800 5000 5400 2.1 0.64 74.1 22.6 1400 128 5.62 0.51 70 43 -20 to +70 100000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRLA0612P0G001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range 1400 5 1200 100% 4 1000 3 800 600 2 400 1 200 0 0 6 PWM PWM duty cycle Static pressure Static pressure 6 (inch H2O) (Pa) 12 VDC DC12 V 1600 50% 20% 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m /min) 3 (CFM) 5 1600 1400 PWM duty cycle 100% PWM100% 18000 10.8 V/12 V/13.2 V 14000 4 1000 12000 3 800 600 2 400 1 200 0 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16000 1200 Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example 10000 8000 17800 min-1 16500 min-1 Inlet Outlet 6000 4000 2000 0.5 1.0 1.5 2.0 2.5 0 10 20 30 40 50 60 70 80 Airflow (m /min) 3 (CFM) 0 100 (%) PWM duty cycle PWM 373 Long Life Fan 60 mm sq. Lead wire ............................................. Inlet DC Storage temperature ........................... -30 to +70C (Non-condensing) Dimensions (unit: mm) Outlet side Inlet side 4-o4.30.3 Mounting hole 40.3 760.5 40.3 600.5 500.3 4-o4.30.3 Mounting hole +50 300 0 Lead wire 600.5 500.3 (10) AWG 26 UL 1430 (10) Rotating direction 300 +50 0 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 59 500.3 4-o4.5 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 374 Resin finger guards page: p. 539 Long Life Fan 60x60x76 mm San Ace 60L 9CRL type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 300 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRL0612P0G001 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] 100 0 Rated current Rated input SPL Operating temperature Expected life [A] [W] Rated speed [min-1] Inlet Outlet [m/min] Max. airflow [CFM] Max. static pressure [Pa] [inchHO] [dB (A)] [C] [h] 2.3 0.22 27.6 2.7 16500 13000 3600 2800 2.0 0.43 70.6 15.1 1000 47.6 4.0 0.19 66 32 -20 to +70 130000/60C * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRL0612P0G001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) PWM duty cycle PWM 100% 2.0 1.0 0 4.0 Static pressure Static pressure 4.0 1000 3.0 5.0 12 VDC DC12 V 1200 800 600 50% 400 200 0 0% 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m3/min) (CFM) 3.0 2.0 1.0 0 (min-1) PWM duty cycle 100% PWM100% 1200 18000 14000 12 V 800 600 10.8 V 400 16500 min-1 Inlet 13000 min-1 12000 10000 8000 Outlet 6000 4000 200 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 16000 13.2 V 1000 Fan speed (inch H2O) (Pa) 5.0 PWM duty - Speed characteristics example 2000 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 80 Airflow 2.5 (m3/min) (CFM) 0 100 (%) PWM PWM duty cycle 375 Long Life Fan 60 mm sq. Lead wire ............................................. Inlet DC Storage temperature ........................... -30 to +70C (Non-condensing) Dimensions (unit: mm) Outlet side Inlet side 600.5 500.3 500.3 600.5 +50 300 0 (10) (10) 4-o4.30.3 Mounting hole 40.3 +50 300 0 Lead wire AWG26 UL 1430 Rotating direction 40.3 760.5 Airflow direction 4-o4.30.3 Mounting hole Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 59 500.3 59 500.3 4- o4.5 29.7 62 .7 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 376 Resin finger guards page: p. 539 Long Life Fan 80x80x25 mm San Ace 80L 9LG type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 130 g Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9LG0812P4J001 9LG0812P4G001 12 10.8 to 13.2 9LG0812P4H001 9LG0824P4J001 9LG0824P4G001 24 21.6 to 26.4 9LG0824P4H001 100 20 100 25 100 25 100 20 100 20 100 30 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.6 0.06 0.3 0.05 0.12 0.04 0.28 0.05 0.14 0.02 0.05 0.02 7.2 0.72 3.6 0.6 1.44 0.48 6.72 1.2 3.36 0.48 1.2 0.48 7400 1800 5500 1400 3700 1100 7400 2400 5500 1200 3700 1100 2.07 0.5 1.54 0.39 1.03 0.3 2.07 0.67 1.54 0.33 1.03 0.3 73.0 17.6 54.3 13.7 36.3 10.5 73.0 23.6 54.3 11.6 36.3 10.5 177 10.4 98 6.3 44 3.9 177 18.6 98 4.6 44 3.9 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 49 16 43 14 31 13 49 22 43 13 31 13 -20 to +70 180000/60C 0.71 0.04 0.39 0.02 0.17 0.01 0.71 0.07 0.39 0.01 0.17 0.01 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 576. Without sensor Pulse sensor The models listed below have pulse sensors. Model no. 9LG0812S4001 9LG0812F4001 9LG0812M4001 9LG0812L4001 9LG0824S4001 9LG0824F4001 9LG0824M4001 9LG0824L4001 Rated voltage Operating voltage range Rated current Rated input [V] 6 to 13.2 12 8 to 13.2 24 12 to 26.4 14 to 26.4 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.17 0.1 0.08 0.06 0.07 0.045 0.04 0.03 2.04 1.2 0.96 0.72 1.68 1.08 0.96 0.72 4200 3300 2900 2300 4200 3300 2900 2300 1.17 0.92 0.8 0.64 1.17 0.92 0.8 0.64 41.3 32.5 28.3 22.6 41.3 32.5 28.3 22.6 56 35 27 17 56 35 27 17 [V] [inchHO] 0.22 0.14 0.11 0.068 0.22 0.14 0.11 0.068 SPL Operating temperature Expected life [dB (A)] [C] [h] 35 29 25 22 35 29 25 22 -20 to +70 180000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor 377 Long Life Fan 80 mm sq. DC Storage temperature ........................... -30 to +70C (Non-condensing) Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0812P4J001 With pulse sensor with PWM control function Operating voltage range 60% 20% 0.5 1.0 20 2.0 1.5 40 60 2.5 (m3/min) 80 Airflow 9LG0812P4G001 PWM PWM duty cycle 100% 60% 25% 1.0 1.5 0.1 0 0 60% 378 1.0 20 1.5 40 2.0 60 2.5 (m /min) 80 3000 Airflow 0 100 (%) PWM duty cycle PWM (CFM) (min-1) PWM duty cycle 100% PWM100% 120 110 100 90 80 70 60 50 40 30 20 10 0 PWM duty - Speed characteristics example 6000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5500 min-1 5000 13.2 V 12 V 10.8 V 4000 3000 2000 1000 0.5 1.0 1.5 2.0 (m3/min) Airflow 25% 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 0 100 (%) PWM duty cycle PWM (CFM) (min-1) PWM duty cycle 100% PWM100% 60 55 50 45 40 35 30 25 20 15 10 5 0 PWM duty - Speed characteristics example 4000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 3700 min-1 3500 3000 13.2 V 12 V 10.8 V 2500 2000 1500 1000 500 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 5 10 15 20 25 30 35 40 (CFM) Airflow 0 100 (%) PWM duty cycle PWM (CFM) With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 24 VDC DC24 V PWM PWM duty cycle 100% 60% 20% 20 0.5 (inch H2O) (Pa) PWM PWM duty cycle 100% 0.5 0 4000 1000 3 0 10 20 30 40 50 60 70 Static pressure Static pressure Static pressure 0.2 0.10 0 12 VDC DC12 V (inch H2O (Pa 0.3 0.15 (CFM) PWM duty cycle 0.4 5000 2000 Operating voltage range Airflow 0.5 0.25 0.20 2.0 (m3/min) 0 5 10 15 20 25 30 35 40 0.6 10.8 V With pulse sensor with PWM control function (inch H2O) (Pa) 0.7 0.35 0.30 0.05 0.5 9LG0812P4H001 0.8 7400 min-1 6000 12 V Fan speed 0.40 PWM duty cycle 200 180 160 140 120 100 80 60 40 20 13.2 V Fan speed Static pressure 0.45 9LG0824P4J001 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 (inch H2O) (Pa) 12 VDC DC12 V Airflow 0 8000 Operating voltage range 0 10 20 30 40 50 60 70 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 (min-1) PWM duty cycle 100% PWM100% With pulse sensor with PWM control function (inch H2O) (Pa) 60 55 50 45 40 35 30 25 20 15 10 5 0 (CFM) PWM duty cycle 120 0.45 110 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0 0 Static pressure PWM PWM duty cycle 100% 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min 80 (CFM 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 7000 26.4 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7400 min-1 6000 Fan speed 0 (inch H2O) (Pa) 12 VDC DC12 V Static pressure 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 24 V 21.6 V 5000 4000 3000 2000 1000 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0824P4G001 With pulse sensor with PWM control function Operating voltage range 20% 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow 9LG0824P4H001 30% 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 20 0.04 10 0 0 0 12 V 6V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 10 9LG0812L4001 20 30 Airflow 40 (m3/min) 15 0 10 8V 5 0 0 40 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0.28 12 V 0.02 24 V 21.6 V 0.4 0.2 5 10 15 0.8 0.6 20 Airflow 25 (m3/min) (CFM) 40 0.12 30 0.08 20 0.04 10 0 0 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 10 20 30 40 Airflow (m3/min) 0.16 40 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 13.2 V 12 V 6V 0.8 0.6 10 20 Airflow 9LG0824F4001 With pulse sensor 0.4 0.2 0 (CFM) 1.0 30 (m3/min) (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 70 50 100 (%) 0 PWM duty cycle PWM 9LG0812M4001 With pulse sensor 0.2 0.4 0.6 0.8 1.0 1.2 0.16 1500 (CFM) 6V 0.20 2000 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 12 V 60 2500 500 13.2 V 0.24 3700 min-1 1000 (inch H2O) (Pa) 13.2 V 0.04 0.16 0 Static pressure Static pressure 0.06 45 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 3000 26.4 V Operating voltage range 25 20 4000 3500 9LG0824S4001 With pulse sensor (inch H2O) (Pa) 0.08 0.18 50 (CFM) Operating voltage range 0.10 (min-1) Operating voltage range Static pressure Static pressure 0.08 60 55 50 45 40 35 30 25 20 15 10 5 0 PWM duty - Speed characteristics example 0 5 10 15 20 25 30 35 40 13.2 V 50 30 100 (%) 0 PWM duty cycle PWM (CFM) (inch H2O) (Pa) 60 0.12 2000 2.0 (m3/min) PWM duty cycle 100% PWM100% 9LG0812F4001 With pulse sensor 70 40 1.5 Airflow (inch H2O) (Pa) 0.16 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 (CFM) Operating voltage range 0.20 3000 Fan speed 70% Airflow 0.24 1.0 Airflow Static pressure Static pressure PWM PWM duty cycle 100% 0 5 10 15 20 25 30 35 40 0.28 0.5 (inch H2O) (Pa) 24 VDC DC24 V 9LG0812S4001 4000 1000 Static pressure 0 21.6 V Operating voltage range (inch H2O) (Pa) 0.24 0.22 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 24 V With pulse sensor with PWM control function PWM duty cycle 60 55 50 45 40 35 30 25 20 15 10 5 26.4 V 0 10 20 30 40 50 60 70 (CFM) 5500 min-1 5000 26.4 V 24 V 12 V 0.2 0.4 0.6 0.8 1.0 1.2 1.4 10 20 30 Airflow 40 (m3/min) 50 (CFM) 0.18 45 0.16 40 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 26.4 V 24 V 12 V 0.2 0.4 0.6 0.8 1.0 1.2 10 20 30 Airflow 40 (m3/min) (CFM) 379 DC 60% 6000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 Long Life Fan 80 mm sq. PWM PWM duty cycle 100% 120 0.45 110 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0 0 (min-1) PWM duty cycle 100% PWM100% Static pressure 120 0.45 110 0.40 100 0.35 90 80 0.30 70 0.25 60 0.20 50 0.15 40 30 0.10 20 0.05 10 0 0 (inch H2O) (Pa) 24 VDC DC24 V Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics 9LG0824M4001 9LG0824L4001 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.16 40 0.14 35 0.12 30 26.4 V 0.10 25 24 V 0.08 20 0.06 15 0.04 10 5 0 0 0 Static pressure Static pressure (inch H2O) (Pa) 0.02 With pulse sensor 12 V 0.2 0.4 10 0.6 0.8 20 1.0 30 Airflow 0.10 25 0.08 20 26.4 V 0.06 15 24 V 0.04 10 0.02 5 0 0 (m3/min) 0 (CFM) 14 V 0.2 5 0.4 10 0.6 15 20 Airflow 0.8 25 (m3/min) (CFM) Dimensions (unit: mm) 71.50.3 800.5 8-o4.30.3 Mounting hole +50 300 0 (10) 71.50.3 Lead wire 800.5 40.3 40.3 AWG26 UL 1430 Rotating direction 25.20.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 0 78.5 71.50.3 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 380 Resin finger guards page: p. 539 Long Life Fan 80x80x80 mm San Ace 80L 9CRL type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Red Black Sensor Yellow Control Brown Orange Gray Sensor Purple Control White Outlet Mass ...................................................... 490 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. 9CRL0812P8G001 [V] [V] 12 10.8 to 13.2 PWM duty cycle* [%] Rated current Rated input 100 0 Rated speed Max. airflow [A] [W] [min-1] Inlet Outlet [m/min] [CFM] 5.3 0.2 63.6 2.4 12000 11300 2000 1900 4.5 0.74 158.9 26.1 Max. static pressure [Pa] [inchHO] 1150 4.62 31.9 0.13 SPL Operating temperature Expected life [dB (A)] [C] [h] 76 30 -20 to +70 130000/60C * PWM frequency: 25 kHz Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9CRL0812P8G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1200 4.0 1000 3.0 2.0 1.0 0 PWM duty cycle PWM 100% 800 600 50% 400 200 0% 0 1.0 2.0 3.0 4.0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 Airflow 5.0 (CFM) 1000 3.0 800 2.0 1.0 0 12 V/13.2 V 1200 4.0 (min-1) PWM duty cycle 100% PWM100% 1400 Static pressure Static pressure 5.0 (inch H2O) (Pa) 12 VDCV DC12 1400 PWM duty - Speed characteristics example 10.8 V Fan speed PWM duty cycle 600 400 200 0 1.0 2.0 3.0 4.0 5.0 (m3/min) 0 20 40 60 80 100 120 140 160 (CFM) 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 12000 min-1 11300 min-1 Inlet Outlet 100 (%) PWM duty cycle PWM Airflow 381 Long Life Fan 80 mm sq. Lead wire ............................................. Inlet DC Storage temperature ........................... -30 to +70C (Non-condensing) Dimensions (unit: mm) Outlet side Inlet side 800.5 71.50.5 800.5 71.50.5 +50 300 0 (10) (10) 4-o4.30.5 Mounting hole Rotating direction 40.3 +50 300 0 40.3 801 Lead wire AWG24 UL 1430 Airflow direction 4-o4.30.5 Mounting hole Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 78.5 78.5 4-o4.5 o8 78.5 71.50.3 o9 78.5 71.50.3 4-o4.5 2 71.50.3 0 71.50.3 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 382 Resin finger guards page: p. 539 Long Life Fan 92x92x25 mm San Ace 92L 9LG type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 150 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9LG0912P4J001 9LG0912P4G001 9LG0912P4S001 9LG0912P4H001 9LG0924P4J001 9LG0924P4G001 9LG0924P4S001 9LG0924P4H001 [V] 12 PWM duty cycle* [%] 10.8 to 13.2 24 21.6 to 26.4 Rated current Rated input Rated speed 100 100 100 100 100 100 100 100 Max. airflow [A] [W] [min-1] [m/min] 0.42 0.3 0.22 0.15 0.21 0.15 0.11 0.07 5.04 3.6 2.64 1.8 5.04 3.6 2.64 1.68 5000 4400 3850 3150 5000 4400 3850 3150 2.2 1.93 1.69 1.38 2.2 1.93 1.69 1.38 [CFM] Max. static pressure [Pa] [inchHO] 77.7 105 68.2 81 59.7 62.1 48.7 41.6 77.7 105 68.2 81 59.7 62.1 48.7 41.6 SPL Operating temperature Expected life [dB (A)] [C] [h] 44 40 37 32 44 40 37 32 -20 to +70 180000/60C 0.42 0.33 0.25 0.17 0.42 0.33 0.25 0.17 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 576. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9LG0912F4001 9LG0912M4001 9LG0912L4001 9LG0924F4001 9LG0924M4001 9LG0924L4001 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.1 0.08 0.07 0.05 0.04 0.03 1.2 0.96 0.84 1.2 0.96 0.72 2800 2400 2000 2800 2400 2000 1.22 1.05 0.87 1.22 1.05 0.87 43.1 37.1 30.7 43.1 37.1 30.7 32.8 24.1 16.7 32.8 24.1 16.7 SPL [inchHO] 0.13 0.097 0.067 0.13 0.097 0.067 Operating temperature Expected life [dB (A)] [C] [h] 29 24 19 29 24 19 -20 to +70 180000/60C The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 576. Without sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0912P4J001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 (inch H2O) (Pa) 12 VDC DC12 V PWM PWM duty cycle 100% 50% 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow (CFM) 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 (min-1) PWM duty cycle 100% PWM100% 120 Static pressure Static pressure 120 PWM duty - Speed characteristics example 5000 13.2 V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 min-1 4000 12 V Fan speed PWM duty cycle 10.8 V 3000 2000 1000 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow (CFM) 0 100 (%) PWM duty cycle PWM 383 Long Life Fan 92 mm sq. DC Storage temperature ........................... -30 to +70C (Non-condensing) Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0912P4G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 120 0.45 0.40 100 0.20 0.15 0.10 0.05 0 PWM duty cycle PWM 100% 60 40 50% 20 0 0.5 1.0 1.5 2.0 9LG0912P4S001 PWM PWM duty cycle Static pressure Static pressure 0.30 100% 40 50% 20 0 0.5 1.0 1.5 Airflow 1.5 2.0 2.5 (m3/min) 0 40 0.15 0.10 PWM duty - Speed characteristics example (min-1) 80 60 5000 12 V 40 0.05 10 0 0 10.8 V 20 0 0.5 1.0 1.5 2.0 (m3/min) 10 20 30 40 50 60 70 2000 100 (%) 0 PWM duty cycle PWM (CFM) 0.5 1.0 1.5 0.15 0.05 5000 12 V 10.8 V 20 3150 min-1 3000 2000 1000 10 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 13.2 V 40 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) (min-1) 50 30 0.10 0 2.0 (m3/min) Airflow 0.30 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 60 50% 0 100 (%) PWM duty cycle PWM (CFM) Airflow With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 24 VDC DC24 V PWM PWM duty cycle Static pressure 100% 50% 0.5 3000 Airflow (inch H2O) (Pa) PWM PWM duty cycle 100% 0 10 20 30 40 50 60 70 120 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 3850 min-1 1000 0 12 VDC DC12 V 9LG0924P4J001 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 13.2 V Operating voltage range 30 20 100 (%) PWM duty cycle PWM (CFM) PWM duty cycle 100% PWM100% 0.20 (CFM) Static pressure Static pressure 50 2000 With pulse sensor with PWM control function 60 Static pressure 0.25 0 2.0 (m3/min) 10 20 30 40 50 60 70 (inch H2O) (Pa) 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow 384 1.0 0.05 PWM duty cycle 0.10 0.5 (inch H2O) (Pa) 12 VDC DC12 V 9LG0912P4H001 0.15 0 3000 1000 20 Operating voltage range 80 0 0.30 10.8 V 40 0 10 20 30 40 50 60 70 80 0.05 0 12 V Airflow 0.20 0.10 0.10 4400 min-1 4000 13.2 V 60 Voltage: 12 V VDC DC12 PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.15 0.15 (CFM) PWM duty cycle 60 0.20 0 2.5 (m3/min) Airflow 0.25 0.25 0.05 0 10 20 30 40 50 60 70 80 0.30 0.40 100 0.35 80 0.30 5000 Fan speed 0.25 80 120 Fan speed 0.30 (min-1) PWM duty cycle 100% PWM100% (CFM) 120 0.45 0.40 100 0.35 80 0.30 0.25 60 0.20 0.15 40 0.10 20 0.05 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 5000 26.4 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 min-1 4000 24 V Fan speed 0.35 Static pressure Static pressure 0.45 (inch H2O) (Pa) 12 VDC DC12 V PWM duty - Speed characteristics example Fan speed PWM duty cycle 21.6 V 3000 2000 1000 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 120 0.45 0.40 100 0.20 0.15 0.10 0.05 0 100% 60 40 50% 20 0 0.5 1.0 1.5 2.0 9LG0924P4S001 0.30 PWM PWM duty cycle 100% 40 50% 0 0.5 1.5 1.0 9LG0924P4H001 30 20 50% 10 0 1.0 0.5 9LG0912F4001 1.5 0.15 0.10 60 0.20 50 2.5 (m3/min) PWM duty - Speed characteristics example (min-1) 5000 24 V 40 21.6 V 2000 1000 0.5 1.0 1.5 2.0 (m3/min) 10 20 30 40 50 60 70 100 (%) 0 PWM duty cycle PWM (CFM) Airflow 0.05 (min-1) PWM duty cycle 100% PWM100% 5000 50 24 V 21.6 V 20 10.2 V 20 10 0.5 20 1.0 30 Airflow 1.5 40 50 2000 1000 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 9LG0912M4001 12 V 30 3150 min-1 3000 10 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 26.4 V 40 30 0.10 PWM duty - Speed characteristics example 100 (%) 0 PWM duty cycle PWM (CFM) 9LG0912L4001 With pulse sensor Operating voltage range 13.8 V 10 3850 min-1 3000 20 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 26.4 V (m3/min) (CFM) 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 With pulse sensor Operating voltage range (inch H2O) (Pa) 0 100 (%) 0 PWM duty cycle PWM (CFM) Airflow With pulse sensor 40 0 0.15 (CFM) Static pressure 0.25 0.30 0 2.0 (m3/min) (inch H2O) (Pa) Static pressure 60 0 Static pressure Static pressure 40 PWM PWM duty cycle 100% Operating voltage range 0 80 60 50 Airflow 0.05 2.0 PWM duty cycle 100% PWM100% (inch H2O) (Pa) 24 VDC DC24 V 0 10 20 30 40 50 60 70 0.10 1.5 Operating voltage range 60 0.15 1.0 With pulse sensor with PWM control function (inch H2O) (Pa) 0 0.5 0.20 (CFM) PWM duty cycle 0.05 0.25 0 2.0 (m3/min) Airflow 0.10 0 0.05 0 10 20 30 40 50 60 70 0.15 2000 1000 (inch H2O) (Pa) Static pressure Static pressure 80 20 3000 20 Operating voltage range 0.05 0.30 21.6 V 40 0 10 20 30 40 50 60 70 80 24 VDC DC24 V 60 24 V Airflow 0.20 0 0.10 4400 min-1 4000 26.4 V 60 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.10 0.15 (CFM) PWM duty cycle 0.15 0.20 0 2.5 (m3/min) Airflow 0.25 0.25 0.05 0 10 20 30 40 50 60 70 80 0.30 0.40 100 0.35 80 0.30 5000 Fan speed 0.25 PWM duty cycle PWM 80 120 Fan speed 0.30 (min-1) PWM duty cycle 100% PWM100% (inch H2O) (Pa) 13.8 V Static pressure 0.35 Static pressure Static pressure 0.45 (inch H2O) (Pa) 24 VDC DC24 V 12 V 10.2 V 0.2 0.4 0.6 0.8 1.0 1.2 10 20 30 Airflow 40 (m3/min) (CFM) 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 13.8 V 12 V 10.2 V 0.2 0.4 0.6 0.8 1.0 1.2 10 20 30 Airflow 40 (m3/min) (CFM) 385 DC (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Long Life Fan 92 mm sq. 9LG0924P4G001 Airflow - Static Pressure Characteristics 9LG0924F4001 9LG0924M4001 With pulse sensor Operating voltage range Operating voltage range 0.15 0.10 0.05 0 50 27.6 V 40 Static pressure Static pressure 0.20 (inch H2O) (Pa) 60 24 V 30 20.4 V 20 10 0 0.5 0 10 1.0 20 30 Airflow 1.5 40 50 0.14 35 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 (m3/min) (inch H2O) (Pa) 27.6 V 24 V 20.4 V 0.2 0.4 0.6 0.8 1.0 1.2 0 (CFM) With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.25 9LG0924L4001 With pulse sensor 10 20 30 Airflow 40 (m3/min) (CFM) 0.12 30 0.10 25 0.08 20 0.06 15 0.04 10 0.02 5 0 0 0 27.6 V 24 V 20.4 V 0.2 0.4 0.6 0.8 1.0 1.2 10 20 30 Airflow 40 (m3/min) (CFM) Dimensions (unit: mm) 82.50.3 920.5 8-o4.30.3 Mounting hole 300 +50 0 (10) 82.50.3 920.5 40.3 Lead wire AWG26 UL 1430 Rotating direction 25.20.5 40.3 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 90.5 4-o4.5 4-o4.5 08 o1 90.5 90.5 82.50.3 82.50.3 7 o9 82.50.3 90.5 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 386 Resin finger guards page: p. 539 Long Life Fan 92x92x38 mm San Ace 92L 9LG type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black Yellow Sensor DC Storage temperature ........................... -30 to +70C (Non-condensing) Brown Control Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9LG0912P1H001 12 10.2 to 13.8 9LG0912P1F001 9LG0924P1H001 24 20.4 to 27.6 9LG0924P1F001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 20 100 20 100 20 Max. airflow [A] [W] [min-1] [m/min] [CFM] 2.0 0.18 1.0 0.11 0.9 0.08 0.5 0.06 24.0 2.16 12.0 1.32 21.6 1.92 12.0 1.44 9000 2700 7000 2000 9000 2700 7000 2000 3.7 1.11 2.9 0.83 3.7 1.11 2.9 0.83 130.6 39.1 102.4 29.3 130.6 39.1 102.4 29.3 Max. static pressure [Pa] 430 38.7 263 21.5 430 38.7 263 21.5 [inchHO] 1.72 0.15 1.05 0.08 1.72 0.15 1.05 0.08 SPL Operating temperature Expected life [dB (A)] [C] [h] 61 30 55 22 61 30 55 22 -20 to +70 180000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0912P1H001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 12 VDC DC12 V 700 2.5 600 0.5 0 PWM PWM duty cycle 100% 400 300 200 100 0 20% 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 2.0 500 1.5 1.0 0.5 0 400 13.8 V 12 V Fan speed Static pressure Static pressure 2.0 500 1.0 (min-1) PWM duty cycle 100% PWM100% 700 2.5 600 1.5 PWM duty - Speed characteristics example 10.2 V 300 200 100 0 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 10000 9000 8000 7000 DC12 V Voltage: 12 VDC PWM25 PWM frequency:kHz 25 kHz 9000 min-1 6000 5000 4000 3000 2000 1000 0 100 (%) duty cycle PWMPWM 387 Long Life Fan 92 mm sq. Mass ...................................................... 270 g Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG0912P1F001 With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 12 VDC DC12 V 350 1.25 300 100 50 20% 0 1 2 3 4 5 0.75 0.5 0.25 0 (m3/min) Airflow Static pressure Static pressure PWM PWM duty cycle 100% 300 200 20% 1 2 3 4 5 1.5 1.0 0.5 0 (m3/min) 9LG0924P1F001 Static pressure Static pressure 300 200 100 0 1 2 3 4 5 PWM PWM duty cycle 100% 150 100 20% 1 10000 9000 8000 7000 DC24 V Voltage: 24 VDC PWM25 PWM frequency:kHz 25 kHz 9000 min-1 6000 5000 4000 3000 2000 1000 0 (m3/min) 100 (%) duty cycle PWMPWM PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 350 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 388 20.4 V 1.25 300 200 0 (min-1) Airflow 1.25 300 1.0 250 100 (%) PWMPWM duty cycle PWM duty - Speed characteristics example 27.6 V 24 V 400 (inch H2O) (Pa) 24 VDC DC24 V 350 0 0 (m3/min) Operating voltage range (inch H2O) (Pa) 50 5 7000 min-1 6000 5000 4000 3000 2000 1000 With pulse sensor with PWM control function PWM duty cycle 0.25 4 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 0.5 3 PWM duty cycle 100% PWM100% 2.0 500 0 20 40 60 80 100 120 140 160 180 (CFM) 0.75 2 2.5 600 400 0 1 700 2.0 500 0 0 (inch H2O) (Pa) 2.5 600 100 50 Airflow 24 VDC DC24 V 700 0.5 100 Operating voltage range (inch H2O) (Pa) 1.0 150 10000 9000 8000 7000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 1.5 12 V 10.2 V 200 0 20 40 60 80 100 120 140 160 180 (CFM) 0 20 40 60 80 100 120 140 160 180 (CFM) 9LG0924P1H001 13.8 V Fan speed 150 1.0 250 Fan speed 0 PWM PWM duty cycle 100% 200 1.0 250 0.75 0.5 0.25 0 27.6 V Fan speed 0.25 Static pressure Static pressure 1.0 250 0.5 (min-1) PWM duty cycle 100% PWM100% 350 1.25 300 0.75 PWM duty - Speed characteristics example 24 V 20.4 V 200 150 100 50 0 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) Airflow 10000 9000 8000 7000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 min-1 6000 5000 4000 3000 2000 1000 0 100 (%) PWMPWM duty cycle Dimensions (unit: mm) 8-o4.30.3 Mounting hole +30 0 (10) 82.50.3 920.5 300 Lead wire AWG24 UL 1430 40.3 82.50.3 40.3 920.5 380.5 Rotating direction Airflow direction 08 o1 Long Life Fan 92 mm sq. 90.5 90.5 82.50.3 90.5 03 o1 4-o4.5 82.50.3 82.50.3 Outlet side 4-o4.5 82.50.3 Inlet side DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 389 Long Life Fan 120x120x38 mm San Ace 120L 9LG type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 420 g Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9LG1212P1G001 9LG1212P1S001 12 8.0 to 13.8 9LG1212P1H001 9LG1224P1G001 9LG1224P1S001 24 15 to 30 48 36 to 60 9LG1224P1H001 9LG1248P1G001 9LG1248P1S001 9LG1248P1H001 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.2 0.24 2.2 0.24 1.4 0.24 1.6 0.12 1.1 0.12 0.7 0.12 0.8 0.08 0.55 0.08 0.35 0.08 38.4 2.88 26.4 2.88 16.8 2.88 38.4 2.88 26.4 2.88 16.8 2.88 38.4 3.84 26.4 3.84 16.8 3.84 6550 2000 5600 2000 4700 2000 6550 2000 5600 2000 4700 2000 6550 2000 5600 2000 4700 2000 7.0 2.13 6.0 2.13 5.0 2.13 7.0 2.13 6.0 2.13 5.0 2.13 7.0 2.13 6.0 2.13 5.0 2.13 247.1 75.2 211.8 75.2 176.5 75.2 247.1 75.2 211.8 75.2 176.5 75.2 247.1 75.2 211.8 75.2 176.5 75.2 370 34.4 270 34.4 190 34.4 370 34.4 270 34.4 190 34.4 370 34.4 270 34.4 190 34.4 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 62 36 58 36 54 36 62 36 58 36 54 36 62 36 58 36 54 36 -20 to +70 180000/60C 1.48 0.13 1.08 0.13 0.76 0.13 1.48 0.13 1.08 0.13 0.76 0.13 1.48 0.13 1.08 0.13 0.76 0.13 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on pp. 576 to 577. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Model no. 9LG1212F1001 9LG1212M1001 9LG1224A1001 9LG1224F1001 9LG1224M1001 9LG1248F1001 9LG1248M1001 Rated voltage Operating voltage range Rated current Rated input [V] 12 [V] 8 to 13.8 24 15 to 30 48 36 to 60 390 Lock sensor Max. airflow Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 0.39 0.22 0.37 0.19 0.11 0.11 0.07 4.68 2.64 8.88 4.56 2.64 5.28 3.36 2800 2100 3700 2800 2100 2800 2100 3 2.2 3.9 3 2.2 3 2.2 106 77.7 137.8 106 77.7 106 77.7 67.6 37.9 117.8 67.6 37.9 67.6 37.9 The following sensor and control options are available for selection. Available for all models. Without sensor Rated speed [A] [inchHO] 0.27 0.15 0.47 0.27 0.15 0.27 0.15 SPL Operating temperature Expected life [dB (A)] [C] [h] 39 33 48 39 33 39 33 -20 to +70 180000/60C Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1212P1G001 With pulse sensor with PWM control function Operating voltage range 300 250 200 100 50 0 0 0 20% 50 100 150 200 250 Airflow Static pressure Static pressure 100% 50% 20% 0 1 2 50 9LG1212P1H001 3 4 5 6 0.5 1.0 Static pressure 100% 50% 50 0 1 2 50 3 100 4 150 Airflow 9LG1224P1G001 5 50 0 0 0 5600 min-1 4000 3000 2000 1000 1 2 50 3 4 5 6 7 (m3/min) 100 150 200 0 Airflow 100 (%) PWM duty cycle PWM (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 250 6000 100 8V 50 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 0.5 0 Static pressure 100 8V 150 2.0 PWM PWM duty cycle 100% 200 0.5 0 (inch H2O) (Pa) 24 VDC DC24 V 250 150 150 12 V 200 (CFM) 300 1.0 12 V 100 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 4700 min-1 4000 3000 2000 1000 1 2 50 3 100 4 150 Airflow 5 6 (m3/min) 0 100 (%) PWM duty cycle PWM 200 (CFM) Operating voltage range 450 350 100 (%) With pulse sensor with PWM control function (inch H2O) (Pa) 1.5 6000 13.8 V 200 0 6 (m3/min) PWM duty cycle 400 (min-1) 13.8 V 20% 0 0 PWM duty cycle 100% PWM100% (inch H2O) (Pa) PWM PWM duty cycle 100 2000 PWM duty - Speed characteristics example Operating voltage range 12 VDC DC12 V 0.5 3000 With pulse sensor with PWM control function 150 0 Airflow 250 0 (CFM) Airflow 250 200 4000 PWM duty cycle PWM (CFM) 200 0 7 (m3/min) 100 150 200 (inch H2O) (Pa) 1.0 50 100 150 200 250 50 PWM duty cycle Static pressure 1.0 50 0 1 2 3 4 5 6 7 8 (m3/min) 300 150 0 0 350 PWM PWM duty cycle 100 5000 1000 (inch H2O) (Pa) 200 0.5 8V Operating voltage range 12 VDC DC12 V 250 6550 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 300 12 V 0 (CFM) PWM duty cycle Static pressure 0 1 2 3 4 5 6 7 8 (m3/min) 9LG1212P1S001 1.0 0.5 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 0.5 50% 150 1.0 13.8 V 50% 1.5 1.0 0.5 20% 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 Airflow (CFM) 0 550 500 450 400 350 300 250 200 150 100 50 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 7000 6000 30 V 24 V 15 V Fan speed 1.0 1.5 7000 Fan speed 350 (min-1) PWM duty cycle 100% PWM100% 500 450 400 350 300 250 200 150 100 50 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6550 min-1 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 9 (m3/min) 50 100 150 200 250 300 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 391 DC PWM duty cycle PWM 100% Static pressure Static pressure 1.5 (inch H2O) (Pa) 12 VDC DC12 V 450 400 Long Life Fan 120 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1224P1S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.5 PWM PWM duty cycle 100% 250 Static pressure 200 150 50% 100 20% 0.5 1 2 50 3 4 5 6 Static pressure Static pressure 50% 20% 50 1 2 50 3 4 100 5 150 Static pressure Static pressure 2.0 PWM PWM duty cycle 100% 200 50% 150 20% 50 100 150 200 250 Static pressure Static pressure 1.5 100% 150 0 0 0 0.5 550 500 450 400 350 300 250 200 150 100 50 0 0 PWM PWM duty cycle 50% 100 0 (inch H2O) (Pa) 48 VDC DC48 V 200 50 24 V 100 2 50 400 350 300 1.0 15 V 4700 min-1 4000 3000 2000 1000 1 2 50 3 4 100 5 150 Airflow 6 (m3/min) 0 100 (%) PWM duty cycle PWM 200 (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 7000 60 V Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6550 min-1 6000 48 V 36 V 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 9 (m3/min) 0 100 (%) PWM duty cycle PWM 50 100 150 200 250 300 (CFM) Airflow 250 0.5 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 6000 48 V 36 V 150 100 4 5 6 100 150 200 Airflow 7 (m3/min) (CFM) 0 0 0 5600 min-1 4000 3000 2000 1000 50 3 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 5000 60 V 200 20% 1 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 Operating voltage range 300 0.5 100 (%) With pulse sensor with PWM control function (inch H2O) (Pa) 250 1.0 (CFM) Airflow 9LG1248P1S001 1.5 0 1 2 3 4 5 6 7 8 (m3/min) PWM duty cycle 1.0 6000 30 V 150 (inch H2O) (Pa) 250 0 0.5 (min-1) PWM duty cycle 100% PWM100% 250 0 48 VDC DC48 V 300 0 0 PWM duty - Speed characteristics example Operating voltage range 450 350 2000 With pulse sensor with PWM control function (inch H2O) (Pa) 0 Airflow 200 200 (CFM) Airflow 9LG1248P1G001 50 1.0 0 6 (m3/min) PWM duty cycle 400 3000 PWM duty cycle PWM (CFM) 50 0 100 50 100 150 200 250 300 PWM duty cycle PWM 100% 0.5 0.5 1 2 3 4 5 6 7 8 (m3/min) (inch H2O) (Pa) 24 VDC DC24 V 100 4000 1000 Operating voltage range 150 0 0 5600 min-1 With pulse sensor with PWM control function 250 200 1.0 15 V 100 0 (CFM) Airflow (inch H2O) (Pa) 392 0 7 (m3/min) 100 150 200 PWM duty cycle 1.5 150 Fan speed 0 9LG1224P1H001 0 24 V 50 0 1.0 30 V 250 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 200 50 0 6000 Fan speed 0.5 350 300 1.0 (min-1) PWM duty cycle 100% PWM100% 400 Fan speed Static pressure 1.0 (inch H2O) (Pa) 24 VDC DC24 V 300 PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1248P1H001 With pulse sensor with PWM control function Operating voltage range 100% 150 0.5 100 50% 20% 50 1 2 50 9LG1212F1001 3 4 100 5 150 Airflow 0 0 0 0.25 13.8 V 0.20 12 V 8V 0 1 9LG1224F1001 2 3 4 0.15 0.10 0.05 0 (m3/min) 5 150 Airflow 6 (m3/min) 200 9LG1224A1001 With pulse sensor 50 40 12 V 30 20 8V 10 Static pressure 80 0 1 60 24 V 40 15 V 20 1 2 3 4 0 20 40 60 80 100 120 140 (m3/min) (CFM) Airflow 9LG1248M1001 60 0.20 50 0.15 0.10 0.05 0 0.7 180 160 0.6 140 0.5 120 20 2 40 60 Airflow 3 0.3 0.2 80 100 24 V 80 60 15 V 40 20 0 1 2 3 4 5 (m3/min) 0 20 40 60 80 100 120 140 160 180 (CFM) (CFM) Airflow 9LG1248F1001 With pulse sensor With pulse sensor Operating voltage range (inch H2O) (Pa) 0.5 120 30 V 24 V 40 30 15 V 20 10 0 0 0 (m3/min) 30 V 0.4 100 0.1 70 30 V With pulse sensor Operating voltage range 13.8 V 0.25 100 (%) 0 PWM duty cycle PWM (CFM) (inch H2O) (Pa) 0.4 100 Static pressure 4 Operating voltage range 0.5 120 0 2000 (inch H2O) (Pa) 9LG1224M1001 With pulse sensor (inch H2O) (Pa) 0 3 100 60 0 (CFM) Operating voltage range 0.1 2 50 (inch H2O) (Pa) 110 100 90 80 70 60 50 40 30 20 10 Airflow 0.2 1 Operating voltage range 0 20 40 60 80 100 120 140 0.3 3000 1000 9LG1212M1001 With pulse sensor Static pressure Static pressure 0.1 0 6 (m3/min) (inch H2O) (Pa) 0.2 36 V 100 200 (CFM) Operating voltage range 0.3 150 0.5 4700 min-1 4000 50 0 0.4 48 V Static pressure 0 200 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 5000 60 V Static pressure 0 250 1.0 6000 DC PWM PWM duty cycle 200 (min-1) PWM duty cycle 100% PWM100% 300 Static pressure Static pressure (inch H2O) (Pa) 48 VDC DC48 V 250 1.0 Long Life Fan 120 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 20 40 2 60 Airflow 3 80 100 (m3/min) (CFM) 60 V 0.4 100 0.3 0.2 0.1 0 80 48 V 60 36 V 40 20 0 1 2 3 4 0 20 40 60 80 100 120 140 (m3/min) (CFM) Airflow With pulse sensor Operating voltage range (inch H2O) (Pa) 70 Static pressure 0.25 0.20 0.15 0.10 0.05 0 60 V 60 50 48 V 40 30 36 V 20 10 0 0 1 20 40 2 60 Airflow 3 80 100 (m3/min) (CFM) 393 Dimensions (unit: mm) 1200.8 104.80.3 8-o4.50.3 Mounting hole +30 300 0 (10) 104.80.3 1200.8 Lead wire AWG24 UL 1430 Rotating direction 6.50.3 3.50.3 380.5 6.50.3 3.50.3 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 104.80.3 117 o1 30 104.80.3 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 394 Resin finger guards Model no.: 109-1000G page: p. 539 Long Life Fan 120x120x38 mm San Ace 120L 9GL type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black or Blue Sensor DC Storage temperature ........................... -30 to +70C (Non-condensing) Yellow Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 9GL1212G101 9GL1212E101 9GL1212H101 9GL1212F101 9GL1212M101 9GL1224G101 9GL1224E101 9GL1224H101 9GL1224F101 9GL1224M101 9GL1248G101 9GL1248E101 9GL1248H101 9GL1248F101 9GL1248M101 [V] 10.2 to 13.8 12 7 to 13.8 20.4 to 27.6 24 14 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.98 0.61 0.38 0.28 0.21 0.5 0.34 0.22 0.16 0.11 0.25 0.17 0.11 0.09 0.07 11.8 7.32 4.56 3.36 2.52 12.0 8.16 5.28 3.84 2.64 12.0 8.16 5.28 4.32 3.36 3600 3100 2600 2280 1950 3600 3100 2600 2280 1950 3600 3100 2600 2280 1950 3.88 3.34 2.8 2.45 2.1 3.88 3.34 2.8 2.45 2.1 3.88 3.34 2.8 2.45 2.1 137 118 99 87 74 137 118 99 87 74 137 118 99 87 74 135 100 70.4 54.2 39.6 135 100 70.4 54.2 39.6 135 100 70.4 54.2 39.6 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.542 0.402 0.283 0.218 0.159 0.542 0.402 0.283 0.218 0.159 0.542 0.402 0.283 0.218 0.159 [C] 49 46 39 36 32 49 46 39 36 32 49 46 39 36 32 [h] 80000/60C 100000/60C 80000/60C -20 to +70 100000/60C 80000/60C 100000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 9GL1212G101 9GL1212E101 With pulse sensor Operating voltage range Operating voltage range 13.8 V 140 12 V 120 0.4 100 0.3 80 0.2 0.1 0 0.5 10.2 V 60 40 20 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 0.4 0.3 0.2 0.35 13.8 V 120 100 Static pressure 0.5 160 Static pressure Static pressure 0.6 (inch H2O) (Pa) 140 180 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.7 9GL1212H101 With pulse sensor 12 V 10.2 V 80 60 40 0.30 0.25 40 0.05 0 0 0 0 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 12 V 60 0.15 0.10 13.8 V 70 50 20 2 80 0.20 0.1 1 90 7V 30 20 10 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 395 Long Life Fan 120 mm sq. Mass ...................................................... 370 g Airflow - Static Pressure Characteristics 9GL1212F101 9GL1212M101 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 0.15 40 0.05 0 12 V 30 7V 20 10 0 1 2 3 4 (m /min) 3 0.15 0.10 50 40 30 0.05 10 0 0 Operating voltage range 0.2 0.35 27.6 V 120 100 Static pressure Static pressure 0.3 24 V 20.4 V 80 60 40 1 2 50 3 4 100 5 150 Airflow 6 (m3/min) 200 Static pressure 24 V 40 30 14 V 20 0.05 10 0 0 0 9GL1248H101 20 2 40 60 Airflow 80 100 60 50 0.15 40 0.10 0.05 0 55.2 V 48 V 40.8 V 30 20 0 1 2 3 4 (m3/min) 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 40 20 0 0.2 0.30 0.25 0.20 0.15 0 3 4 100 5 150 6 (m3/min) 200 Airflow (CFM) With pulse sensor 90 80 60 50 0.15 40 0.10 27.6 V 70 24 V 30 14 V 20 10 0 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow With pulse sensor Operating voltage range 140 55.2 V 140 48 V 120 40.8 V 60 40 20 0 1 2 50 3 100 4 5 150 Airflow 6 (m3/min) 200 0.5 120 0.4 100 0.3 0.2 55.2 V 48 V 40.8 V 80 60 40 0.1 20 0 0 1 0 (CFM) 9GL1248M101 With pulse sensor 2 50 3 4 100 5 150 Airflow 6 (m3/min) 200 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 90 70 80 70 60 55.2 V 50 48 V 40 30 40.8 V 20 10 0 2 50 (inch H2O) (Pa) 160 80 1 9GL1248E101 With pulse sensor 180 0.3 20.4 V 60 0.20 0 100 0.05 10 0.25 0.05 0.4 0.35 70 0.30 0 (inch H2O) (Pa) 80 0.2 10 Operating voltage range 90 0.20 14 V 0 Static pressure 0.25 24 V 9GL1248F101 With pulse sensor 80 0.35 20 (CFM) (inch H2O) (Pa) 0.30 0.5 0 3 (m3/min) Operating voltage range 0.35 0.6 0.1 1 0.3 Airflow 27.6 V 50 100 0 20 40 60 80 100 120 140 (CFM) 0.7 60 0.4 Operating voltage range (inch H2O) (Pa) 70 24 V 120 9GL1224F101 Operating voltage range (inch H2O) (Pa) 27.6 V 140 0 27.6 V 9GL1248G101 With pulse sensor 160 (CFM) 30 (CFM) Operating voltage range Static pressure 0.10 180 (inch H2O) (Pa) 60 0.15 0 0.10 80 100 With pulse sensor 70 40 0.05 0.15 60 Airflow 80 50 0 0.20 40 3 (m /min) 90 0.20 20 9GL1224M101 Static pressure 0.25 0 0 396 0.30 0.1 0.25 20 2 (inch H2O) (Pa) 140 0.5 0 3 Operating voltage range (inch H2O) (Pa) 0.4 1 9GL1224H101 With pulse sensor 0.6 0.1 0 Airflow 0.5 7V 20 0 20 40 60 80 100 120 140 (CFM) 9GL1224E101 12 V Static pressure 50 0.20 Static pressure 60 0.20 0.10 13.8 V 70 0.7 13.8 V 60 Static pressure 0.25 0.25 Static pressure 0.30 (inch H2O) (Pa) 70 80 With pulse sensor Operating voltage range (inch H2O) (Pa) 90 Static pressure Static pressure 0.35 9GL1224G101 With pulse sensor 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0.25 60 0.20 50 55.2 V 40 48 V 0.15 0.10 40.8 V 30 20 0.05 10 0 0 1 0 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) Dimensions (unit: mm) 8-o4.30.3 Mounting hole (10) 1190.8 104.80.3 +30 300 0 Lead wire AWG24 UL 1007 6.50.3 3.50.3 104.80.3 1190.8 6.50.3 3.50.3 380.5 Rotating direction Airflow direction Outlet side 104.80.3 4-o4.5 o1 117 104.80.3 117 30 27 o1 4-o4.5 104.80.3 104.80.3 Long Life Fan 120 mm sq. Inlet side DC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 117 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1000G page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 397 Long Life Fan 140x140x38 mm San Ace 140L 9LG type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 640 g Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9LG1412P1A001 9LG1412P1H001 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 9LG1412P1M001 9LG1424P1A001 9LG1424P1H001 9LG1424P1M001 9LG1448P1A001 9LG1448P1H001 9LG1448P1M001 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.72 0.27 1.7 0.27 0.6 0.16 1.86 0.17 0.85 0.16 0.3 0.11 0.92 0.11 0.42 0.11 0.15 0.09 44.64 3.24 20.4 3.24 7.2 1.92 44.64 4.08 20.4 3.84 7.2 2.64 44.16 5.28 20.16 5.28 7.2 4.32 6900 2300 5200 2300 3300 1300 6900 2300 5200 2300 3300 1300 6900 2300 5200 2300 3300 1300 8.0 2.66 6.0 2.66 3.7 1.45 8.0 2.66 6.0 2.66 3.7 1.45 8.0 2.66 6.0 2.66 3.7 1.45 282 93 212 93 130 51 282 93 212 93 130 51 282 93 212 93 130 51 516 80 300 80 170 26 516 80 300 80 170 26 516 80 300 80 170 26 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 68 39 62 39 46 29 68 39 62 39 46 29 68 39 62 39 46 29 -20 to +70 180000/60C 2.07 0.32 1.2 0.32 0.68 0.1 2.07 0.32 1.2 0.32 0.68 0.1 2.07 0.32 1.2 0.32 0.68 0.1 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 577. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Model no. 9LG1412L1001 9LG1424L1001 9LG1448L1001 Rated voltage Operating voltage range Rated current Rated input Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 12 24 48 10.2 to 13.8 20.4 to 27.6 40.8 to 55.2 0.27 0.17 0.11 3.3 4.1 5.3 2300 2300 2300 2.6 2.6 2.6 91.9 91.9 91.9 80 80 80 Without sensor Differs according to the model. Refer to the table on p. 577. Lock sensor 398 Max. airflow [V] The following sensor and control options are available for selection. Available for all models. Rated speed [V] [inchHO] 0.32 0.32 0.32 SPL Operating temperature Expected life [dB (A)] [C] [h] 39 39 39 -20 to +70 180000/60C Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1412P1A001 With pulse sensor with PWM control function Operating voltage range 20% 100 0 1 2 3 4 5 6 7 8 9 Static pressure 50% 0.6 150 0.4 100 0 20% 1 2 50 3 4 5 6 7 (m3/min) 100% 50% 20% 2000 1000 0 0 0.8 200 0.6 150 0 (m3/min) 0 6 7 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 4000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 3500 3300 min-1 3000 13.8 V/12 V 10.2 V 2500 2000 1500 1000 50 500 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow (inch H2O) (Pa) 24 VDC DC24 V 700 PWM PWM duty cycle 100% 400 300 2.5 600 50% 20% 2.0 500 1.5 1.0 100 0.5 0 0 0 5 0 20 40 60 80 100 120 140 160 (CFM) Static pressure Static pressure 0.5 4 Operating voltage range (inch H2O) (Pa) 200 3 100 150 200 250 (CFM) With pulse sensor with PWM control function PWM duty cycle 1.0 2 0.4 100 Airflow 1.5 50 1.0 250 0 20 40 60 80 100 120 140 160 (CFM) 2.0 500 3000 50 0.2 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 9LG1424P1A001 4000 0.2 1 5200 min-1 5000 0.4 100 1.2 300 PWM PWM duty cycle 50 600 6000 10.2 V 0.6 150 (inch H2O) (Pa) 12 VDC DC12 V Static pressure Static pressure 0.8 200 0 1.0 250 0 7000 12 V Operating voltage range 1.2 300 0.2 8000 13.8 V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 0.4 100 (min-1) 1.0 250 Airflow 9LG1412P1M001 0.6 150 100 (%) PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.2 300 100 150 200 250 (CFM) PWM duty cycle 0.8 200 0 PWM duty cycle PWM (CFM) Airflow 1.4 350 0.8 200 0 50 100 150 200 250 300 1.6 400 PWM PWM duty cycle 100% 1.0 250 0 1 2 3 4 5 6 7 8 9 (m3/min) (inch H2O) (Pa) 12 VDC DC12 V 1.2 300 3000 1000 Operating voltage range 1.4 350 4000 2000 100 0 5000 With pulse sensor with PWM control function (inch H2O) (Pa) 50 200 0 (CFM) PWM duty cycle 0.2 300 Airflow 9LG1412P1H001 Static pressure 0 (m3/min) 50 100 150 200 250 300 0.5 10.2 V Fan speed 0 1.0 400 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 Airflow (m3/min) (CFM) 400 300 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 8000 27.6 V 7000 20.4 V 5000 4000 3000 2000 100 0 6900 min-1 6000 24 V 200 0 DC24 V Voltage: 24 VDC PWM25 PWM frequency:kHz 25 kHz 1000 1 2 3 4 5 6 7 8 9 (m3/min) 50 100 150 200 250 300 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 399 DC 200 1.5 6900 min-1 6000 12 V Fan speed 0 50% 2.0 500 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 Fan speed 0.5 Static pressure Static pressure 1.0 300 8000 13.8 V 2.5 600 400 (min-1) PWM duty cycle 100% PWM100% 700 PWM PWM duty cycle 100% 2.0 500 1.5 (inch H2O) (Pa) 12 VDC DC12 V 600 Long Life Fan 140 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1424P1H001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) Static pressure 0.8 200 50% 0.4 100 0 0 0 1 2 50 3 4 5 6 7 (m3/min) Static pressure Static pressure 1000 0 0 PWM duty cycle PWM 100% 50% 20% 9LG1448P1A001 Static pressure Static pressure 50% 20% 1.0 0 0 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 2500 2000 1500 0 (m3/min) 100 (%) PWM duty cycle PWM PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 8000 55.2 V 6900 min-1 6000 48 V 40.8 V 300 200 5000 4000 3000 2000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 400 0 (CFM) 1000 1 2 3 4 5 6 7 8 9 (m3/min) 50 100 150 200 250 300 0 100 (%) PWM duty cycle PWM (CFM) Airflow With pulse sensor with PWM control function (inch H2O) (Pa) 48 VDC DC48 V Static pressure 0.8 200 50% 0.4 100 20% 0.8 200 6 7 (m3/min) Airflow 3000 1000 0 5 0 1 50 2 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 5200 min-1 4000 2000 0 4 5000 0.4 100 50 3 6000 40.8 V 0.6 150 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 1.0 250 0.2 100 150 200 250 (CFM) 8000 48 V 1.2 300 50 2 (min-1) 55.2 V 1.4 350 1.0 250 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.6 400 PWM PWM duty cycle 100% 50 3300 min-1 500 Operating voltage range 1 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 1000 Airflow 1.2 300 Static pressure 1.5 0.5 (inch H2O) (Pa) 400 4000 50 2.0 500 100 0 (min-1) 27.6 V/24 V/20.4 V 2.5 600 300 9LG1448P1H001 0 PWM duty - Speed characteristics example 3000 700 PWM duty cycle 0.2 Airflow 3500 (inch H2O) (Pa) 400 1.4 350 100 (%) PWM PWM duty cycle Airflow PWM PWM duty cycle 100% 2.0 500 0 (m3/min) 0 20 40 60 80 100 120 140 160 (CFM) 48 VDC DC48 V 0.6 150 7 Operating voltage range 600 0 6 With pulse sensor with PWM control function (inch H2O) (Pa) 0 5 0.4 100 0 (m3/min) PWM duty cycle 0.5 4 0.6 150 0.2 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 200 3 100 150 200 250 (CFM) PWM duty cycle 100% PWM100% 0.8 200 Airflow 1.0 2 50 1.0 250 0 20 40 60 80 100 120 140 160 (CFM) 1.5 1 1.2 300 1.0 250 0 2000 50 (inch H2O) (Pa) 24 VDC DC24 V 50 3000 0.2 Operating voltage range 1.2 300 0.2 4000 0.4 100 0 5200 min-1 5000 With pulse sensor with PWM control function (inch H2O) (Pa) 0.4 100 20.4 V 0.6 150 Airflow PWM duty cycle 0.6 150 0.8 200 100 150 200 250 (CFM) 9LG1424P1M001 0.8 200 1.0 250 Fan speed 50 6000 Fan speed 0.2 20% Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 24 V 1.2 300 Fan speed 0.6 150 8000 27.6 V 1.4 350 1.0 250 (min-1) PWM100% PWM duty cycle 100% 1.6 400 PWM PWM duty cycle 100% 1.2 300 Static pressure (inch H2O) (Pa) 24 VDC DC24 V 1.4 350 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1448P1M001 With pulse sensor with PWM control function Operating voltage range 0.8 200 PWM PWM duty cycle 100% 0.6 150 0.2 0 50% 20% 50 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Operating voltage range 0.3 0.2 0.1 0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 80 60 40 20 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 PWM duty cycle PWM 9LG1448L1001 With pulse sensor (inch H2O) (Pa) 0.2 0.1 0 (m3/min) 0.5 120 0.4 100 0.3 0 20 40 60 80 100 120 140 160 (CFM) 80 20.4 V/24 V/27.6 V 60 40 20 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0 20 40 60 80 100 120 140 160 Airflow With pulse sensor Operating voltage range 0.5 120 10.2 V/12 V/13.8 V 100 (%) 0 (m3/min) Airflow Static pressure Static pressure 0.4 100 500 (inch H2O) (Pa) 0.5 120 1500 1000 Operating voltage range (inch H2O) (Pa) 2000 50 9LG1424L1001 With pulse sensor 2500 0 20 40 60 80 100 120 140 160 (CFM) Airflow 9LG1412L1001 40.8 V 0.4 100 0 (m3/min) 55.2 V/48 V 0.6 150 0 20 40 60 80 100 120 140 160 (CFM) 3300 min-1 3000 0.8 200 0.2 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 3500 1.0 250 Static pressure 0.4 100 4000 DC 1.0 250 (min-1) PWM duty cycle 100% PWM100% 1.2 300 Static pressure Static pressure (inch H2O) (Pa) 48 VDC DC48 V 1.2 300 Long Life Fan 140 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle (m3/min) (CFM) Airflow 0.4 100 0.3 0.2 80 40.8 V/48 V/55.2 V 60 40 0.1 0 20 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0 20 40 60 80 100 120 140 160 (m3/min) (CFM) Airflow Dimensions (unit: mm) 8-o4.50.3 Mounting hole 380.5 +30 300 0 1400.8 124.50.5 (10) Lead wire AWG 22 UL 3266 124.50.5 1400.8 Rotating direction 40.2 60.4 40.2 60.4 Airflow direction 401 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 124.50.3 124.50.3 4-o4.5 50 47 o1 138 138 Options Model no.: 109-719, 109-719H 402 124.50.3 138 138 124.50.3 o1 Finger guards 4-o4.5 page: p. 533 Long Life Fan 140x140x51 mm San Ace 140L 9LG type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 790 g Specifications The models listed below have pulse sensors with PWM control function. Model no. Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 9LG1412P5G001 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 9LG1412P5S001 9LG1424P5G001 9LG1424P5S001 9LG1448P5G001 9LG1448P5S001 100 20 100 20 100 20 100 20 100 20 100 20 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 5.16 0.31 1.83 0.31 2.58 0.16 0.91 0.16 1.29 0.12 0.45 0.12 62 3.72 22 3.72 62 3.84 22 3.84 62 5.76 22 5.76 7500 2300 5000 2300 7500 2300 5000 2300 7500 2300 5000 2300 9.0 2.75 6.0 2.75 9.0 2.75 6.0 2.75 9.0 2.75 6.0 2.75 318 97 212 97 318 97 212 97 318 97 212 97 655 80 295 80 655 80 295 80 655 80 295 80 [inchHO] SPL Operating temperature Expected life [dB (A)] [C] [h] 69 38 57 38 69 38 57 38 69 38 57 38 -20 to +70 180000/60C 2.63 0.32 1.18 0.32 2.63 0.32 1.18 0.32 2.63 0.32 1.18 0.32 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 577. Without sensor Pulse sensor Lock sensor The models listed below have pulse sensors. Model no. 9LG1412A5001 9LG1412H5001 9LG1412M5001 9LG1424A5001 9LG1424H5001 9LG1424M5001 9LG1448A5001 9LG1448H5001 9LG1448M5001 Rated voltage Operating voltage range Rated current Rated input [V] [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.61 1 0.43 1.21 0.55 0.23 0.66 0.31 0.15 31.4 12 5.16 29.1 13.2 5.52 31.7 14.9 7.2 5700 4100 2600 5700 4100 2600 5700 4100 2600 6.9 4.9 3.1 6.9 4.9 3.1 6.9 4.9 3.1 243.8 173.1 109.5 243.8 173.1 109.5 243.8 173.1 109.5 500 260 100 540 260 100 540 260 100 [inchHO] 2 1.04 0.4 2.17 1.04 0.4 2.17 1.04 0.4 SPL Operating temperature Expected life [dB (A)] [C] [h] 61 52 40 61 52 40 61 52 40 -20 to +70 180000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor 403 Long Life Fan 140 mm sq. DC Storage temperature ........................... -30 to +70C (Non-condensing) Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1412P5G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 2.5 600 100% Static pressure 2.0 500 0.5 0 50% 300 200 20% 100 0 1 2 3 4 5 6 7 8 9 10 (m /min) 0 50 100 150 200 250 300 350 12 V 10.2 V 1 2 3 4 5 6 7 8 9 10 (inch H2O) (Pa) 0.4 100 0 20% 50 0 0 1 2 50 3 4 5 6 7 (m3/min) 100 150 200 0 PWM duty cycle PWM Static pressure 100% 400 50% 200 20% 100 0 1 2 3 4 5 6 7 8 9 10 0.6 150 2000 1000 0 0 7 (m3/min) 50% 0.4 100 20% 1 50 2 0 100 (%) PWM duty cycle PWM (CFM) Airflow PWM duty - Speed characteristics example (min-1) 8000 27.6 V 7000 24 V 6000 2.0 500 20.4 V 1.5 400 300 1.0 200 0.5 100 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7500 min-1 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 9 10 0 (m3/min) 100 (%) PWM duty cycle PWM (CFM) Airflow 3 4 5 6 100 150 200 Airflow 7 (m3/min) (CFM) PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 1.8 450 1.6 400 Static pressure Static pressure 404 6 0 50 100 150 200 250 300 350 PWM PWM duty cycle 100% 0.6 150 0 5 PWM duty cycle 100% PWM100% (inch H2O) (Pa) 24 VDC DC24 V 0.8 200 0 4 Operating voltage range 1.0 250 0 3 100 150 200 With pulse sensor with PWM control function (inch H2O) (Pa) 50 2 50 3.5 900 800 3.0 700 2.5 600 (CFM) PWM duty cycle 1.2 300 3000 50 Airflow 9LG1424P5S001 4000 0.2 1 5000 min-1 5000 0.4 100 0 (m3/min) 0 50 100 150 200 250 300 350 0.2 10.2 V 0.8 200 (inch H2O) (Pa) 2.0 500 0.5 1.0 250 0 24 VDC DC24 V 2.5 600 1.0 6000 Operating voltage range 700 300 7000 12 V 1.2 300 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 1.5 8000 13.8 V Airflow 9LG1424P5G001 (min-1) 1.4 350 (CFM) PWM duty cycle Static pressure 1.6 400 50% PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.8 450 PWM PWM duty cycle 100% Static pressure Static pressure (inch H2O) (Pa) 0.8 200 0.2 100 (%) PWM duty cycle PWM Airflow 12 VDC DC12 V 0.6 150 0 (m /min) 3 Operating voltage range 1.0 250 3000 With pulse sensor with PWM control function PWM duty cycle 1.2 300 4000 1000 Airflow 9LG1412P5S001 5000 2000 0 50 100 150 200 250 300 350 (CFM) (CFM) 7500 min-1 6000 1.5 400 300 1.0 200 0.5 100 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 7000 2.0 500 0 3 13.8 V Fan speed 1.0 400 8000 Fan speed 1.5 (min-1) PWM duty cycle 100% PWM100% 3.5 900 800 3.0 700 2.5 600 8000 27.6 V 6000 24 V 1.2 300 1.0 250 20.4 V 0.8 200 0.6 150 5000 3000 2000 0.2 50 1000 0 0 1 50 2 3 4 5 6 100 150 200 Airflow 7 (m3/min) (CFM) 5000 min-1 4000 0.4 100 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 7000 1.4 350 Fan speed Static pressure (inch H2O) (Pa) 12 VDC DC12 V 700 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9LG1448P5G001 With pulse sensor with PWM control function Operating voltage range PWM PWM duty cycle Static pressure 100% 2.0 500 0 200 20% 100 0 1 2 3 4 5 6 7 8 9 10 (m3/min) 0 50 100 150 200 250 300 350 48 V/55.2 V 1.5 400 300 1.0 200 0.5 100 0 1 2 3 4 5 6 7 8 9 10 50% 0.4 100 20% 50 0 1 2 50 9LG1412A5001 3 4 5 6 7 (m3/min) 100 150 200 Airflow 0.6 150 10.2 V 300 200 0 1 2 3 4 5 6 7 8 9 10 0 50 100 150 200 250 300 350 (m3/min) 50 1000 0 0 2.0 500 0.5 0 5 6 7 (m3/min) Airflow 9LG1412M5001 With pulse sensor 0.5 120 0.4 100 10.2 V 0.4 100 50 0 0 1 2 50 3 4 5 6 7 200 100 Airflow 0 1 2 3 4 5 6 7 8 9 10 (m3/min) 0 50 100 150 200 250 300 350 (CFM) Airflow 0 0 40 20 0 1 2 3 4 (m3/min) (CFM) Airflow With pulse sensor Operating voltage range 0.5 120 0.4 100 20.4 V 0.4 100 0 60 9LG1424M5001 With pulse sensor 0.6 150 50 80 0 20 40 60 80 100 120 140 24 V/27.6 V 0.8 200 0.2 0.1 10.2 V/12 V/13.8 V (inch H2O) (Pa) 1.0 250 300 0.2 100 150 200 250 (CFM) 1.2 300 20.4 V 0.3 0 (m3/min) (inch H2O) (Pa) 24 V/27.6 V With pulse sensor Operating voltage range 0.6 150 0.2 100 (%) 0 PWM duty cycle PWM (CFM) Operating voltage range 1.5 400 1.0 4 12 V/13.8 V 0 Static pressure Static pressure 600 3 100 150 200 (inch H2O) (Pa) 9LG1424H5001 With pulse sensor (inch H2O) (Pa) 2.5 2 50 0.8 200 Airflow 9LG1424A5001 3000 0.2 (CFM) Operating voltage range 4000 2000 1 5000 min-1 5000 0.4 100 1.0 250 12 V 400 700 40.8 V 0.8 200 1.2 300 0.5 100 0 6000 (inch H2O) (Pa) Static pressure Static pressure 1.0 1.0 250 0 13.8 V 2.0 500 1.5 1.2 300 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 Operating voltage range (inch H2O) (Pa) 2.5 600 8000 48 V 9LG1412H5001 With pulse sensor (min-1) 55.2 V 1.4 350 (CFM) Operating voltage range 700 1.6 400 Static pressure Static pressure 0.8 200 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1.8 450 PWM duty cycle PWM 100% 1.0 250 0 PWM duty cycle PWM (CFM) Airflow (inch H2O) (Pa) 48 VDCV DC48 1.2 300 0 100 (%) 0 (m3/min) Operating voltage range (inch H2O) (Pa) 0.2 3000 With pulse sensor with PWM control function PWM duty cycle 0.6 150 4000 1000 Airflow 9LG1448P5S001 5000 2000 0 50 100 150 200 250 300 350 (CFM) 7500 min-1 6000 40.8 V 2.0 500 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 7000 Fan speed 0.5 50% 300 8000 Static pressure 1.0 400 3.5 900 800 3.0 700 2.5 600 Static pressure 1.5 (min-1) PWM duty cycle 100% PWM100% 1 2 50 3 4 5 6 7 (m3/min) 100 150 200 250 (CFM) Airflow 0.3 0.2 0.1 0 20.4 V/24 V/27.6 V 80 60 40 20 0 1 2 3 4 0 20 40 60 80 100 120 140 (m3/min) (CFM) Airflow 405 DC 700 2.5 600 Static pressure (inch H2O) (Pa) 48 VDC DC48 V Long Life Fan 140 mm sq. (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics 9LG1448A5001 9LG1448H5001 With pulse sensor Operating voltage range Operating voltage range 400 300 200 0.5 100 0 0 1 2 3 4 5 6 7 8 9 10 0.4 100 Static pressure 1.0 0.5 120 40.8 V/48 V/55.2 V 1.0 250 40.8 V/48 V/55.2 V Static pressure Static pressure 600 2.0 500 1.5 (inch H2O) (Pa) 1.2 300 700 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (m3/min) 0 0 50 100 150 200 250 300 350 (CFM) Airflow 1 2 50 3 4 5 6 7 100 150 200 250 (CFM) Airflow (10) 1400.8 124.50.5 Rated voltage 12 V fan 12 V Lead wire AWG AWG20 20 UL UL3266 3266 Rated voltage V fan 24/4824 VV/48 Lead wire AWG AWG22 22 UL UL3266 3266 40.2 60.4 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 124.50.3 124.50.3 .5 4 -o o1 o1 138 Options Model no.: 109-719, 109-719H 406 124.50.3 58 138 124.50.3 48 138 138 Finger guards .5 o4 4- 4 page: p. 533 0.1 80 60 40 20 0 1 2 Airflow +30 300 0 40.2 60.4 0.2 40.8 V/48 V/55.2 V 3 4 0 20 40 60 80 100 120 140 510.5 124.50.5 1400.8 0.3 0 (m3/min) Dimensions (unit: mm) 8-o4.50.3 Mounting hole With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 2.5 9LG1448M5001 With pulse sensor (m3/min) (CFM) Long Life Fan o 172x150x51 mm San Ace 172L 9L type Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black or Blue Sensor DC Storage temperature ........................... -30 to +70C (Non-condensing) Yellow Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109L5712H501 109L5712M501 109L5724H501 109L5724M501 109L5748H501 109L5748M501 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.2 0.48 0.58 0.2 0.28 0.11 14.4 5.76 13.92 4.8 13.44 5.28 3050 2000 3050 2000 3050 2000 6.4 4.2 6.4 4.2 6.4 4.2 226 148 226 148 226 148 137.2 67.6 137.2 67.6 137.2 67.6 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 52 41 52 41 52 41 -20 to +70 100000/60C 0.551 0.271 0.551 0.271 0.551 0.271 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109L5712H501 109L5712M501 With pulse sensor Operating voltage range Operating voltage range 0.6 150 0.4 100 0.2 50 0.35 13.8 V 0.30 12 V Static pressure Static pressure (inch H2O) (Pa) 200 10.2 V 0 0 1 2 3 4 5 6 7 8 (m3/min) 0 50 100 150 200 250 Airflow (CFM) 70 0.20 50 0.15 40 0.05 0 13.8 V 80 60 0.10 (inch H2O) (Pa) 90 0.25 With pulse sensor Operating voltage range 12 V Static pressure (inch H2O) (Pa) 0.8 109L5724H501 With pulse sensor 10.2 V 30 20 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 24 V 20.4 V 10 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 1 2 3 4 5 6 7 8 (m3/min) 0 50 100 150 200 250 Airflow (CFM) 407 Long Life Fan o172 mm Mass ...................................................... 760 g Airflow - Static Pressure Characteristics 109L5724M501 109L5748H501 With pulse sensor Operating voltage range Operating voltage range 80 70 0.25 60 0.20 50 0.15 40 0.10 0.05 0 0.8 27.6 V 24 V Static pressure Static pressure 0.30 (inch H2O) (Pa) 90 20.4 V 30 20 (inch H2O) (Pa) 200 0.6 150 0.4 100 0.2 50 0.35 55.2 V 0.30 48 V 40.8 V 1 0 2 50 3 4 100 5 150 Airflow 0 6 (m3/min) 200 0 1 2 3 4 5 6 7 8 (m3/min) 0 (CFM) 50 100 150 200 250 Airflow (CFM) Dimensions (unit: mm) (10) 1620.5 o1720.8 4-o4.50.3 Mounting hole +30 300 0 Lead wire AWG24 UL 1007 1500.8 7.50.4 Rotating direction 7.50.4 510.8 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 2- R4 .25 1620.3 o1 68 148 8.5 2-o4.5 Options Finger guards Model no.: 109-319E, 109-319H, 109-320 408 page: p. 534 90 70 60 0.20 50 0.15 40 0.10 0 55.2 V 80 0.25 0.05 10 0 With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.35 109L5748M501 With pulse sensor 48 V 40.8 V 30 20 10 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) Long Life Fan o 172x51 mm San Ace 172L 9L type Round type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Lead wire ............................................. Red Black or Blue Sensor DC Storage temperature ........................... -30 to +70C (Non-condensing) Yellow Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109L1712H501 109L1712M501 109L1724H501 109L1724M501 109L1748H501 109L1748M501 [V] 12 10.2 to 13.8 24 20.4 to 27.6 48 40.8 to 55.2 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.2 0.48 0.58 0.2 0.28 0.11 14.4 5.76 13.92 4.8 13.44 5.28 3050 2000 3050 2000 3050 2000 6.4 4.2 6.4 4.2 6.4 4.2 226 148 226 148 226 148 137.2 67.6 137.2 67.6 137.2 67.6 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] [h] 47 36 47 36 47 36 -20 to +70 100000/60C 0.551 0.271 0.551 0.271 0.551 0.271 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109L1712H501 109L1712M501 With pulse sensor Operating voltage range 0.35 150 0.4 100 0.2 50 0.30 Static pressure Static pressure 13.8 V 0.6 12 V 10.2 V 0.25 0 1 2 3 4 5 6 7 8 (m3/min) 0 50 100 150 200 250 Airflow (CFM) 90 70 0.15 40 0 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 12 V 60 50 0.10 13.8 V 80 0.20 0.05 0 (inch H2O) (Pa) (inch H2O) (Pa) 200 With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 0.8 109L1724H501 With pulse sensor Operating voltage range 10.2 V 30 20 24 V 20.4 V 10 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) 1 2 3 4 5 6 7 8 (m3/min) 0 50 100 150 200 250 Airflow (CFM) 409 Long Life Fan o172 mm Mass ...................................................... 780 g Airflow - Static Pressure Characteristics 109L1724M501 109L1748H501 With pulse sensor Operating voltage range Operating voltage range 80 0.15 40 0.10 0.05 0 24 V 60 50 0.35 55.2 V 70 0.20 (inch H2O) (Pa) 200 20.4 V 30 20 0.6 150 0.4 100 0.2 50 0.30 Static pressure 0.25 0.8 27.6 V Static pressure Static pressure 0.30 90 48 V 40.8 V 1 0 2 50 3 4 100 5 150 Airflow 0 6 (m /min) 3 200 0 1 2 3 4 5 6 7 8 (m /min) 3 0 (CFM) 50 100 150 200 250 Airflow (CFM) Dimensions (unit: mm) 8-o4.50.3 Mounting hole +30 300 0 o1720.8 1620.5 (10) Lead wire AWG24 UL 1007 1620.5 7.50.4 7.50.4 510.8 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4- R4 .25 1620.3 o1 68 1620.3 8.5 4-o4.5 Options Finger guards page: p. 534 Model no.: 109-1066, 109-1068, 109-319E, 109-319H, 109-320 410 0.25 90 70 0.15 40 0 48 V 60 50 0.10 55.2 V 80 0.20 0.05 10 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.35 109L1748M501 With pulse sensor 40.8 V 30 20 10 0 1 0 2 50 3 100 4 150 Airflow 5 6 (m3/min) 200 (CFM) Wide Temperature Range Fan These fans can be used in a wide temperature range from -40 to +85C. Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 9GT 04 12 P 3 J 001 Type name Frame size Voltage PWM control function Frame thickness Speed code Individual customer s spec Type name 9GT Frame size (mm) 12 12 24 24 Frame thickness (mm) 1 38 3 28 Speed code J 4 25 How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature (85C for Wide Temperature Range Fans). For more information, please refer to the technical material section. 411 Wide Temperature Range Fan Voltage (V) DC 04 06 08 09 12 40 x 40 60 x 60 80 x 80 92 x 92 120 x 120 Wide Temperature Range Fan 40x40x28 mm San Ace 40T 9GT type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 85C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -40 to +85C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 55 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GT0412P3J001 12 10.2 to 13.8 9GT0424P3J001 24 20.4 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 30 100 30 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.31 0.08 0.15 0.05 3.72 0.96 3.6 1.2 11700 4100 11700 4100 0.52 0.18 0.52 0.18 18.4 6.36 18.4 6.36 206 25.2 206 25.2 [inchHO] 0.827 0.1 0.827 0.1 SPL Operating temperature Expected life [dB (A)] [C] [h] 48 21 48 21 -40 to +85 40000/85C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0412P3J001 With pulse sensor with PWM control function Operating voltage range 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 412 (inch H2O) (Pa) 12 VDC DC12 V PWM PWM duty cycle 100% Static pressure Static pressure (inch H2O) (Pa) 60% 30% 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 12000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 11700 min-1 10000 13.8 V 12 V Fan speed PWM duty cycle 10.2 V 8000 6000 4000 2000 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 5 10 15 Airflow 20 (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0424P3J001 With pulse sensor with PWM control function Operating voltage range 1.2 300 1.0 250 0.8 150 0.4 100 0.2 50 0 PWM PWM duty cycle 100% 200 0.6 (inch H2O) (Pa) 24 VDC DC24 V Static pressure Static pressure (inch H2O) (Pa) 60% 30% 0 5 10 15 Airflow 20 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 1.2 0 (min-1) PWM duty cycle 100% PWM100% 12000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 11700 min-1 10000 27.6 V 24 V 20.4 V 8000 6000 4000 2000 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 (CFM) PWM duty - Speed characteristics example Fan speed PWM duty cycle 5 10 15 Airflow 20 0 100 (%) PWM duty cycle PWM (CFM) Dimensions (unit: mm) DC 8-o3.50.3 320.3 400.3 320 Wide Temperature Range Fan 40 mm sq. Mounting hole +30 0 (10) Lead wire AWG28 UL 3266 320.3 400.3 40.3 Rotating direction 280.5 40.3 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39 (17.6) 39 4-o3.7 40 (17.6) 320.3 320.3 Options Finger guards page: p. 532 Model no.: 109-059, 109-059H 413 Wide Temperature Range Fan 60x60x25 mm San Ace 60T 9GT type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 85C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -40 to +85C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 100 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GT0612P4G001 12 10.2 to 13.8 9GT0624P4G001 24 20.4 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 30 100 30 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.56 0.11 0.28 0.06 6.72 1.32 6.72 1.44 10000 4100 10000 4100 1.26 0.52 1.26 0.52 44.5 18.3 44.5 18.3 243 42.8 243 42.8 [inchHO] 0.97 0.17 0.97 0.17 SPL Operating temperature Expected life [dB (A)] [C] [h] 52 25 52 25 -40 to +85 40000/85C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 573. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 414 (inch H2O) (Pa) 12 VDC DC12 V PWM duty cycle PWM 100% Static pressure Static pressure (inch H2O) (Pa) 60% 30% 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 12000 13.8 V 10000 12 V Fan speed 9GT0612P4G001 10.2 V Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 10000 min-1 8000 6000 4000 2000 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0624P4G001 With pulse sensor with PWM control function Operating voltage range 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) 24 VDC DC24 V PWM duty cycle PWM 100% Static pressure Static pressure (inch H2O) (Pa) 60% 30% 0 0.4 0 10 0.8 20 30 1.2 40 Airflow 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 1.6 (m3/min) 50 1.2 (min-1) PWM duty cycle 100% PWM100% 12000 27.6 V 10000 24 V 20.4 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 10000 min-1 8000 6000 4000 2000 0 0 (CFM) PWM duty - Speed characteristics example Fan speed PWM duty cycle 0.4 10 0.8 20 1.2 30 40 Airflow 1.6 (m3/min) 50 0 100 (%) PWM duty cycle PWM (CFM) Dimensions (unit: mm) DC Wide Temperature Range Fan 60 mm sq. 300 500.3 600.5 8-o4.30.3 Mounting hole +50 0 (10) 500.3 600.5 Lead wire AWG26 40.3 40.3 250.5 UL 3266 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 59 29.7 500.3 62 . 7 59 500.3 29.7 Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H 415 Wide Temperature Range Fan 80x80x25 mm San Ace 80T 9GT type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 85C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -40 to +85C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 130 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GT0812P4S001 12 10.2 to 13.8 9GT0824P4S001 24 20.4 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 30 100 30 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.46 0.09 0.22 0.05 5.52 1.08 5.28 1.2 6700 2650 6700 2650 1.86 0.73 1.86 0.73 65.7 25.7 65.7 25.7 143 22.3 143 22.3 [inchHO] 0.57 0.08 0.57 0.08 SPL Operating temperature Expected life [dB (A)] [C] [h] 46 26 46 26 -40 to +85 40000/85C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 573. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) Static pressure 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 200 180 160 140 120 100 80 60 40 20 0 0 416 (inch H2O) (Pa) 12 VDC DC12 V 0.8 0.7 PWM duty cycle PWM 100% Static pressure 0.8 60% 30% 0.6 0.5 0.4 0.3 0.2 0.1 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 0 (min-1) PWM duty cycle 100% PWM100% 200 180 160 140 120 100 80 60 40 20 0 PWM duty - Speed characteristics example 8000 13.8 V 7000 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6700 min-1 6000 12 V Fan speed 9GT0812P4S001 10.2 V 5000 4000 3000 2000 1000 0.5 20 1.0 40 1.5 60 Airflow 2.0 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0824P4S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) Static pressure 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 200 180 160 140 120 100 80 60 40 20 (inch H2O) (Pa) 24 VDC DC24 V 0.8 0.7 PWM duty cycle PWM 100% Static pressure 0.8 60% 30% 0.6 0.5 0.4 0.3 0.2 0.1 0 0.5 0 1.0 20 1.5 40 60 Airflow 2.0 2.5 (m3/min) 80 0 0 (CFM) (min-1) PWM duty cycle 100% PWM100% 200 180 160 140 120 100 80 60 40 20 0 PWM duty - Speed characteristics example 8000 27.6 V 7000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6700 min-1 6000 24 V Fan speed PWM duty cycle 20.4 V 5000 4000 3000 2000 1000 0.5 20 1.0 1.5 40 2.0 60 Airflow 2.5 (m3/min) 80 (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) DC 300 +50 0 (10) 40.3 Lead wire 71.50.3 800.5 Wide Temperature Range Fan 80 mm sq. 71.50.3 800.5 8-o4.30.3 Mounting hole 40.3 25.20.5 AWG26 UL 3266 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 71.50.3 4-o4.5 78.5 71.50.3 0 o9 78.5 Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H. 109-049C 417 Wide Temperature Range Fan 92x92x25 mm San Ace 92T 9GT type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 85C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -40 to +85C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 150 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GT0912P4J001 12 10.2 to 13.8 9GT0924P4J001 24 20.4 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 30 100 30 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.42 0.07 0.21 0.05 5.04 0.84 5.04 1.2 5000 1850 5000 1850 2.2 0.81 2.2 0.81 77.7 28.7 77.7 28.7 105 14.3 105 14.3 [inchHO] 0.42 0.05 0.42 0.05 SPL Operating temperature Expected life [dB (A)] [C] [h] 44 18 44 18 -40 to +85 40000/85C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on p. 573. Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 120 PWM duty cycle PWM 100% 100 80 60% 60 40 30% 20 0 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow 418 (inch H2O) (Pa) 12 VDC DC12 V 140 Static pressure Static pressure (inch H2O) (Pa) (CFM) 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 140 5000 13.8 V 120 10.2 V 80 60 40 5000 min-1 3000 2000 1000 20 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4000 12 V 100 Fan speed 9GT0912P4J001 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0924P4J001 With pulse sensor with PWM control function Operating voltage range 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 120 (inch H2O) (Pa) 24 VDC DC24 V 140 PWM duty cycle PWM 100% Static pressure Static pressure (inch H2O) (Pa) 100 80 60% 60 40 30% 20 0 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 Airflow 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 PWM duty - Speed characteristics example 5000 27.6 V 120 20.4 V 80 60 40 5000 min-1 3000 2000 1000 20 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 24 V 100 0.5 1.0 1.5 2.0 2.5 (m3/min) 0 10 20 30 40 50 60 70 80 (CFM) (min-1) PWM duty cycle 100% PWM100% 140 Fan speed PWM duty cycle Airflow (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) DC 300 +50 0 (10) 40.3 40.3 Lead wire 82.50.3 920.5 Wide Temperature Range Fan 92 mm sq. 82.50.3 920.5 8-o4.30.3 Mounting hole 25.20.5 AWG26 UL 3266 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 90.5 4-o4.5 4-o4.5 08 o1 90.5 90.5 82.50.3 7 o9 82.50.3 82.50.3 90.5 82.50.3 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C 419 Wide Temperature Range Fan 92x92x38 mm San Ace 92T 9GT type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 85C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -40 to +85C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 270 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GT0912P1M001 12 10.2 to 13.8 9GT0924P1M001 24 20.4 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 30 100 30 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.5 0.3 0.75 0.15 18.0 3.6 18.0 3.6 8100 3750 8100 3750 3.3 1.5 3.3 1.5 116.6 53.0 116.6 53.0 315 72.0 315 72.0 [inchHO] 1.26 0.29 1.26 0.29 SPL Operating temperature Expected life [dB (A)] [C] [h] 58 37 58 37 -40 to +85 40000/85C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 573. Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0912P1M001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 400 300 1.5 PWM duty cycle PWM 100% Static pressure Static pressure 1.5 (inch H2O) (Pa) 12 VDC DC12 V 1.0 200 0.5 0 100 0 60% 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 420 (min-1) PWM duty cycle 100% PWM100% 10000 8000 12 V 10.2 V 1.0 200 0.5 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 13.8 V 300 30% 1 400 PWM duty - Speed characteristics example Fan speed PWM duty cycle 100 0 8100 min-1 6000 4000 2000 1 2 3 4 (m3/min) 0 20 40 60 80 100 120 140 (CFM) Airflow 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT0924P1M001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 300 1.5 PWM duty cycle PWM 100% Static pressure Static pressure 1.5 (inch H2O) (Pa) 24 VDC DC24 V 400 1.0 200 0.5 0 100 0 60% 2 3 4 (min-1) PWM duty cycle 100% PWM100% 400 10000 8000 24 V 20.4 V 1.0 200 0.5 0 (m3/min) 100 0 1 2 3 4 6000 4000 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow Airflow 8100 min-1 2000 0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 120 140 (CFM) Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 27.6 V 300 30% 1 PWM duty - Speed characteristics example Fan speed PWM duty cycle Dimensions (unit: mm) +30 0 Wide Temperature Range Fan 92 mm sq. 300 DC 8-o4.30.3 Mounting hole 920.5 82.50.3 (10) Lead wire AWG24 UL 3266 40.3 82.50.3 920.5 Rotating direction 380.5 40.3 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Outlet side Inlet side 82.50.3 4-o4.5 08 o1 90.5 90.5 82.50.3 03 o1 4-o4.5 90.5 82.50.3 82.50.3 90.5 Options Finger guards page: p. 532 Model no.: 109-099E, 109-099H, 109-099C 421 Wide Temperature Range Fan 120x120x38 mm San Ace 120T 9GT type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 85C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -40 to +85C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 420 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9GT1212P1S001 12 9.0 to 13.8 9GT1224P1S001 24 18.0 to 27.6 PWM duty cycle* [%] Rated current Rated input Rated speed 100 35 100 35 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.2 0.48 1.1 0.24 26.4 5.76 26.4 5.76 5600 2900 5600 2900 6.0 3.0 6.0 3.0 211.8 106.0 211.8 106.0 270 85.6 270 85.6 [inchHO] 1.08 0.34 1.08 0.34 SPL Operating temperature Expected life [dB (A)] [C] [h] 58 41 58 41 -40 to +85 40000/85C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 573. Without sensor Lock sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT1212P1S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 250 150 0.5 60% 100 35% 1.0 0 0 422 12 V 250 0.5 150 9V 100 50 2 3 4 5 6 100 150 200 Airflow 7 (m3/min) (CFM) 0 0 0 5600 min-1 4000 3000 2000 1000 50 1 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 200 50 0 6000 13.8 V 300 200 (min-1) PWM duty cycle 100% PWM100% 350 PWM PWM duty cycle 100% Static pressure Static pressure 1.0 (inch H2O) (Pa) 12 VDC DC12 V 300 PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 50 2 3 4 5 6 100 150 200 Airflow 7 (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GT1224P1S001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.5 PWM PWM duty cycle 100% 250 200 150 0.5 60% 100 35% 1.0 50 0 350 6000 250 24 V 18 V 150 100 1 0 50 2 3 4 5 6 0 7 (m3/min) 100 150 200 Airflow 0 0 (CFM) 5600 min-1 4000 3000 2000 1000 50 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 27.6 V 200 0.5 (min-1) PWM duty cycle 100% PWM100% 400 300 Static pressure Static pressure 1.0 (inch H2O) (Pa) 24 VDC DC24 V 300 PWM duty - Speed characteristics example Fan speed PWM duty cycle 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) DC 300 Wide Temperature Range Fan 120 mm sq. 104.80.3 1200.8 8-o4.50.3 Mounting hole +30 0 (10) Lead wire 104.80.3 1200.8 AWG24 UL 3266 6.50.3 3.50.3 Rotating direction 380.5 6.50.3 3.50.3 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 104.80.3 104.80.3 117 o1 30 4-o4.5 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H 423 424 G Proof Fan These fans are suitable for cooling CT scanners and other devices subject to high G-force or vibration. Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 24 Frame size P Voltage Type name PWM control function 1 G Frame thickness 001 Speed code Individual customer s spec (3 digits) 9GP Frame size (mm) 12 57 120 x 120 o 172 x 150 (sidecut) Voltage (V) 24 24 48 48 Frame thickness (mm) 1 38 5 51 Speed code G H DC Type name 12 How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 425 G Proof Fan 9GP G Proof Fan 120x120x38 mm San Ace 120GP 9GP type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 440 g G-force tolerance ................................. 735 m/s2 (75 G) for 1000 hours (Measured with our G-force testing machine.) Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9GP1224P1G001 15 to 30 48 9GP1248P1G001 36 to 60 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 20 100 20 [W] 1.6 0.12 0.8 0.08 38.4 2.88 38.4 3.84 Max. airflow Max. static pressure [min-1] [m/min] [CFM] [Pa] 6550 2000 6550 2000 7.0 2.13 7.0 2.13 247 75.2 247 75.2 370 34.4 370 34.4 [inchHO] 1.48 0.13 1.48 0.13 SPL Operating temperature Expected life [dB (A)] [C] [h] 62 36 62 36 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 573. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 350 PWM PWM duty cycle 2.0 100% Static pressure Static pressure 1.5 400 (inch H2O) (Pa) 24 VDC DC24 V 450 300 1.0 250 200 0.5 150 50% 20% 100 1.5 1.0 0.5 50 0 0 0 426 1 2 3 4 5 6 7 8 (m3/min) 50 100 150 200 250 Airflow (CFM) 0 550 500 450 400 350 300 250 200 150 100 50 0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 7000 6000 30 V 24 V Fan speed 9GP1224P1G001 15 V Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6550 min-1 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 9 50 100 150 200 250 300 Airflow (m3/min) (CFM) 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GP1248P1G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 2.0 PWM PWM duty cycle 400 100% 350 Static pressure Static pressure 1.5 (inch H2O) (Pa) 48 VDC DC48 V 450 300 1.0 250 200 0.5 50% 20% 150 100 1.5 1.0 0.5 50 0 0 1 2 3 4 5 6 7 8 0 50 100 150 200 250 0 (m3/min) 0 7000 6000 60 V 48 V 36 V Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6550 min-1 5000 4000 3000 2000 1000 1 2 3 4 5 6 7 8 9 (m3/min) 0 Airflow (min-1) PWM duty cycle 100% PWM100% 550 500 450 400 350 300 250 200 150 100 50 (CFM) PWM duty - Speed characteristics example Fan speed PWM duty cycle 50 100 150 200 250 300 (CFM) Airflow 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) G Proof Fan 120 mm sq. 1200.8 104.80.3 DC 8-o4.50.3 hole Mounting +30 300 0 (10) 104.80.3 1200.8 Lead wire AWG 24 UL 1430 6.50.3 3.50.3 Rotating direction 6.50.3 3.50.3 380.5 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-o4.5 104.80.3 117 o1 30 104.80.3 117 Options Finger guards page: p. 533 Model no.: 109-019E, 109-019K, 109-019C, 109-019H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1000G page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) 427 G Proof Fan o 172x150x51 mm San Ace 172GP 9GP type Sidecut type General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 880 g G-force tolerance ................................. 735 m/s2 (75 G) for 1000 hours (Measured with our G-force testing machine.) Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9GP5724P5H001 16 to 30 48 9GP5748P5G001 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 20 100 20 5.0 0.5 5.0 0.41 Max. airflow [min-1] [W] 120 12.0 240 19.7 8000 3000 10500 3700 Max. static pressure [m/min] [CFM] [Pa] 12.3 4.6 16.1 5.6 434 162 568 198 1000 175 1600 250 [inchHO] 4.02 0.7 6.43 1.01 SPL Operating temperature Expected life [dB (A)] [C] [h] 77 51 83 57 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GP5724P5H001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 900 4.0 100% 3.0 2.0 1.0 0 600 50% 300 0 0 428 1200 Static pressure Static pressure 4.0 (inch H2O) (Pa) 24 VDC DC24 V 1200 20% 4 8 12 100 200 300 400 500 Airflow 16 (m3/min) (CFM) 1.0 0 (min-1) PWM duty cycle 100% PWM100% 10000 30 V 24 V 900 3.0 2.0 PWM duty - Speed characteristics example 8000 Fan speed PWM duty cycle 16 V 600 300 0 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 8000 min-1 6000 4000 2000 4 8 12 100 200 300 400 500 Airflow 16 (m3/min) (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9GP5748P5G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM PWM duty cycle 100% 6.0 1500 4.0 3.0 2.0 1.0 0 900 600 50% 20% 300 0 4 8 12 16 20 0 100 200 300 400 500 600 700 5.0 1200 4.0 3.0 2.0 12000 72 V 48 V 6.0 1500 5.0 1200 (min-1) PWM duty cycle 100% PWM100% 7.0 1800 Static pressure Static pressure (inch H2O) (Pa) 48 VDC DC48 V 7.0 1800 PWM duty - Speed characteristics example 10000 Fan speed PWM duty cycle 36 V 900 600 1.0 300 0 (m3/min) 0 10500 min-1 8000 6000 4000 2000 4 8 12 16 20 0 100 200 300 400 500 600 700 (CFM) Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 (m3/min) (CFM) Airflow Airflow 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) 8-o4.50.3 Mounting hole DC +30 0 G Proof Fan o172 mm 30 0 1620.5 o1720.8 10 Lead wire AWG 18 UL 1430 55.5 7.50.4 55.5 7.50.4 510.8 1500.8 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 8.5 4- R4 .2 5 1620.5 o1 68 4-o4.5 55. 55.5 5 147 Options Finger guards page: p. 534 Model no.: 109-319J, 109-319E, 109-319H, 109-320 429 430 Centrifugal Fan Cooling fan blows air in a centrifugal course. It features high static pressure. Related product: Splash Proof Centrifugal Fan p. 329 Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 9T Type name M 48 Impeller size P Voltage 4 H 01 PWM control function Thickness Speed code P 0 H Individual customer s spec (2 to 3 digits) Bracket-mounted Centrifugal Fan 48 Impeller size Voltage Type name Impeller size (mm) PWM control function Thickness Speed code 9B1T 9T G, GA o 175 J M N P S o 133 o 100 o 150 o 221 o 225 Voltage (V) 24 24 Thickness (mm) 0 69 min. , 99, 119 Speed code H G 001 Individual customer s spec (3 digits) 48 48 1 35 DC Type name P 4 25 Centrifugal Fan 9B1T etc. How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 431 Centrifugal Fan o 100x25 mm San Ace C100 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Control Brown Mass ...................................................... 150 g Specifications When the optional inlet nozzle (109-1080) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9TM24P4H01 24 21.6 to 26.4 9TM48P4H01 48 36 to 60 PWM duty cycle* [%] Rated current Rated input Rated speed 100 0 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.44 0.05 0.22 0.04 10.56 1.2 10.56 1.92 6400 2000 6400 2000 1.77 0.51 1.77 0.51 62.5 18.0 62.5 18.0 560 48 560 48 [inchHO] 2.25 0.19 2.25 0.19 SPL Operating temperature Expected life [dB (A)] [C] [h] 60 34 60 34 -20 to +70 40000/60C * PWM frequency: 25 kHz Max input is 14 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 600 Static pressure 1.0 0.5 0 700 2.5 2.0 500 1.5 (inch H2O) (Pa) 24 VDC DC24 V PWM PWM duty cycle 100% 400 300 50% 200 100 Static pressure 2.5 0% 0 0.5 1.0 1.5 0.5 0 2.0 (m3/min) 0 10 20 30 40 50 60 70 1.0 (CFM) 0 2.5 PWM PWM duty cycle 100% 400 300 50% 200 100 0 0% 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow 432 (inch H2O) (Pa) 48 VDC DC48 V 600 (CFM) Static pressure Static pressure 0.5 4000 3000 2000 2000 min-1 1000 100 0.5 1.0 1.5 2.0 (m3/min) 100 (%) 0 PWM duty cycle PWM (CFM) Operating voltage range 2.0 500 1.0 200 5000 With pulse sensor with PWM control function (inch H2O) (Pa) 1.5 21.6 V 300 0 6400 min-1 6000 24 V 400 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 Airflow PWM duty cycle 2.5 7000 26.4 V 600 0 10 20 30 40 50 60 70 Airflow 9TM48P4H01 (min-1) PWM100% PWM duty cycle 100% 2.0 500 1.5 PWM duty - Speed characteristics example Fan speed PWM duty cycle 600 2.0 500 1.5 1.0 0.5 0 400 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 60 V 48 V 36 V 300 200 100 7000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 6000 Fan speed 9TM24P4H01 6400 min-1 5000 4000 3000 2000 2000 min-1 1000 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) Airflow direction .3 0 6 o5 251 18.51 Lead wire AWG26 UL 1007 50.51 o741 o1001 8.50.5 (10) o721 +30 300 0 3-M4 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side Inlet nozzle side 4-o4 .5 o5 6 3-o4 0.5 o11 20 6.6 1 0. 5 0.5 DC 120 .5 o106 12 Centrifugal Fan o100 mm 0 (1.15) Reference Diagram for Mounting Inlet nozzle (5) Finger guard (27) Fan Bolt length: 5mm mm max. 5 Options Finger guards Model no.: 109-099E, 109-099H page: p. 532 Inlet nozzle page: p. 537 Model no.: 109-1080 433 Centrifugal Fan o 133x91 mm San Ace C133 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 660 g Specifications When the optional inlet nozzle (109-1069) is mounted. The models listed below have pulse sensors with PWM control function. [V] [V] PWM duty cycle* [%] 24 48 20.4 to 27.6 36 to 72 100 100 Rated voltage Operating voltage range Model no. 9TJ24P0H61 9TJ48P0H01 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.2 0.55 28.8 26.4 4150 4150 6.39 6.39 226 226 395 395 [inchHO] 1.59 1.59 SPL Operating temperature Expected life [dB (A)] [C] [h] 61 61 -20 to +70 40000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range 200 0.5 0 50% 100 0 1 0 9TJ48P0H01 2 3 4 5 6 50 100 150 200 Airflow 7 Static pressure 0 434 2 3 4 5 6 7 (m /min) 50 100 150 200 250 (CFM) 3 2000 0 100 (%) PWM duty cycle PWM Airflow PWM duty cycle PWM 100% 50% 1 2 3 4 5 6 50 100 150 200 Airflow 7 (m3/min) 250 (CFM) (min-1) 5000 48 V/72 V 1.5 400 4000 36 V 300 1.0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 2.0 500 100 0 1 0 (inch H2O) (Pa) DC48 V 48 VDC 400 0 0 250 (CFM) 300 0.5 0 3000 1000 100 Operating voltage range 2.0 500 200 200 0.5 4150 min-1 4000 300 1.0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 1.0 20.4 V/ 24 V/27.6 V 1.5 400 (m3/min) PWM duty cycle 1.5 5000 Fan speed 300 1.0 (min-1) PWM duty cycle 100% PWM100% 2.0 500 PWM duty cycle PWM 100% 400 PWM duty - Speed characteristics example Fan speed Static pressure 1.5 (inch H2O) (Pa) DC24 V 24 VDC 2.0 500 Static pressure (inch H2O) (Pa) Static pressure 9TJ24P0H61 200 0.5 0 1 0 4150 min-1 3000 2000 1000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 2 3 4 5 6 7 (m /min) 50 100 150 200 250 (CFM) 3 Airflow 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) (10) 911 60.61 46.81 45 Lead wire AWG24 UL 1430 271 4-M4 o1331 o92.81 Airflow direction +30 300 0 1 o5 8 0.3 o77.81 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side Inlet nozzle side 4-o4.5 45 o580.5 o11 80 .5 o1080 .5 4-o4 Centrifugal Fan o133 mm DC .5 131 (2) Reference Diagram for Mounting Fan Finger guard Bolt length: 6mm mm max. 6 Inlet nozzle Options Finger guards Model no.: 109-1112 page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1069, 109-1069H 435 Centrifugal Fan o 150x35 mm San Ace C150 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 330 g Specifications When the optional inlet nozzle (109-1081) is mounted. The models listed below have pulse sensors with PWM control function. [V] [V] PWM duty cycle* [%] 24 48 20.4 to 27.6 36.0 to 55.2 100 100 Rated voltage Operating voltage range Model no. 9TN24P1H01 9TN48P1H01 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.62 0.32 14.9 15.4 3800 3800 3.83 3.83 135 135 410 390 [inchHO] 1.65 1.57 SPL Operating temperature Expected life [dB (A)] [C] [h] 59 59 -20 to +70 40000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9TN24P1H01: 21.4 W, 9TN48P1H01: 22 W. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1.5 (inch H2O) (Pa) 24 VDC DC24 V 500 400 2.0 500 PWM PWM duty cycle 100% 300 1.0 200 0.5 0 50% 100 0 1 2 3 4 5 1.5 400 PWM PWM duty cycle 100% 300 1.0 200 50% 100 1 2 3 4 5 (m3/min) Airflow Static pressure Static pressure 2 3 4 5 3000 2000 0 (m3/min) 100 (%) PWM PWM duty cycle 25 50 75 100 125 150 175 (CFM) Airflow 1.5 55.2 V 300 48 V 200 0 (min-1) 4000 400 1.0 0.5 PWM duty - Speed characteristics example PWM100% PWM duty cycle 100% 2.0 500 0 25 50 75 100 125 150 175 (CFM) 436 1 (inch H2O) (Pa) 48 VDC DC48 V 2.0 500 0 3800 min-1 1000 Operating voltage range (inch H2O) (Pa) 0 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function PWM duty cycle 0.5 20.4 V 100 0 Airflow 1.5 24 V 200 0 25 50 75 100 125 150 175 (CFM) 9TN48P1H01 27.6 V 300 0 (m3/min) 4000 400 1.0 0.5 (min-1) PWM duty cycle 100% PWM100% Fan speed Static pressure 2.0 PWM duty - Speed characteristics example Fan speed PWM duty cycle Static pressure 9TN24P1H01 36 V 3800 min-1 3000 2000 1000 100 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 1 2 3 4 5 (m3/min) 0 25 50 75 100 125 150 175 (CFM) Airflow 0 100 (%) PWM PWM duty cycle Dimensions (unit: mm) Airflow direction 351 27.81 1 45 Lead wire AWG24 UL 1430 o1501 o1051 51.21 8.51 +30 300 0 (10) 4-M4 o89 o64 .41 0. 3 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side o1 2 o11 80. 5 7 0. 5 4 Centrifugal Fan o150 mm DC 0.5 45 o64-o4.5 Inlet nozzle side 4-o4 .5 (1) Reference Diagram for Mounting Inlet nozzle (7) Fan (41) Finger guard Boltmm6 length: 4mm to 6 mm. 4 Options Finger guards Model no.: 109-1104, 109-1104H page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1081, 109-1081H 437 Centrifugal Fan o 175x69 mm San Ace C175 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 720 g Specifications When the optional inlet nozzle (109-1073) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9TGA24P0H001 16 to 36 48 9TGA48P0G001 36 to 72 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 100 15 Max. airflow [A] [W] [min-1] [m/min] 4.8 0.14 3.5 0.07 115 3.36 168 3.36 4950 800 5700 800 15.3 2.5 17.6 2.5 [CFM] Max. static pressure [Pa] 541 830 88.3 21.8 622 1100 88.3 21.8 [inchHO] 3.33 0.088 4.42 0.088 SPL Operating temperature Expected life [dB (A)] [C] [h] 77 38 80 38 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9TGA24P0H001: 210 W, 9TGA48P0G001: 325 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9TGA24P0H001 With pulse sensor with PWM control function Operating voltage range 1000 PWM PWM duty cycle 100% 800 600 400 200 15% 0 5 10 15 20 (m3/min) 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 0 100 200 300 400 500 600 700 (CFM) 800 600 400 15% 5 10 15 20 (m3/min) 0 100 200 300 400 500 600 700 (CFM) Airflow 438 400 0 4950 min-1 4000 3000 2000 1000 200 (inch H2O) (Pa) PWM duty cycle PWM 100% 1000 0 16 V 5 10 15 20 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow Static pressure Static pressure 48 VDCV DC48 1200 200 800 600 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5000 24 V/36 V Operating voltage range (inch H2O) (Pa) 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 1000 6000 With pulse sensor with PWM control function PWM duty cycle 4.5 4.0 (min-1) PWM duty cycle 100% PWM100% 0 100 200 300 400 500 600 700 (CFM) Airflow 9TGA48P0G001 1200 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 1200 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 6000 48 V/72 V 1000 800 36 V 600 400 5700 min-1 4000 3000 2000 1000 200 0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 5000 Fan speed 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 (inch H2O) (Pa) 24 VDC DC24 V 1200 Static pressure Static pressure (inch H2O) (Pa) PWM duty - Speed characteristics example Fan speed PWM duty cycle 5 10 15 20 (m3/min) 0 100 200 300 400 500 600 700 (CFM) Airflow 0 100 (%) PWM duty cycle PWM 52.91 AWG20 UL 3266 271 Lead wire o58 0.3 o1751 o1311 +30 300 -0 o80.21 Airflow direction 1 4-M4 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) o1 58 o14 8 0.5 .5 Centrifugal Fan o175 mm 45 4-o4.5 o580.5 0 Inlet nozzle side 4-o 4-o 4.5o 4.5 15 8 0. 5 o14 8 0.5 DC Fan side 45 Reference Diagram for Mounting Inlet nozzle Finger guard (14) (2) 0.5 691 61.51 45 4-o4.5 Dimensions (unit: mm) Fan Bolt length:66mm mm max. Options Finger guards Model no.: 109-722, 109-722H page: p. 533 Inlet nozzle page: p. 537 Model no.: 109-1073, 109-1073H 439 Centrifugal Fan o 175x69 mm San Ace C175 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 750 g Specifications When the optional inlet nozzle (109-1073) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] 9TG24P0G01 9TG24P0S01 9TG48P0G01 [V] 24 20.4 to 27.6 48 36 to 55.2 PWM duty cycle* [%] Rated current Rated input Rated speed 100 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.9 2.35 1.95 93.6 56.4 93.6 4700 3900 4700 14.0 11.6 14.0 494.7 409.8 494.7 885 609 885 [inchHO] 3.55 2.45 3.55 SPL Operating temperature Expected life [dB (A)] [C] [h] 73 69 73 -20 to +60 -20 to +70 40000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input is 130 W at rated voltage. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 578. Without sensor Pulse sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range Static pressure (inch H2O) (Pa) 1200 4.5 1100 4.0 1000 PWM PWM duty cycle 3.5 900 100% 800 3.0 700 2.5 600 50% 2.0 500 1.5 400 300 1.0 200 0.5 100 0 3 0 2 4 6 8 10 12 14 16 18 (m /min) 0 100 200 300 400 500 600 Airflow 440 (inch H2O) (Pa) DC24 V 24 VDC (CFM) 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 5000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4700 min-1 4000 27.6 V 24 V Fan speed PWM duty cycle Static pressure 9TG24P0G01 20.4 V 3000 2000 1000 2 4 6 8 10 12 14 16 18 (m3/min) 0 100 200 300 400 500 600 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9TG24P0S01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) PWM duty cycle PWM 2.5 600 100% 2.0 500 1.5 400 300 1.0 200 0.5 100 50% 0 2 0 100 200 300 400 500 (CFM) 2.5 600 27.6 V 3000 2.0 500 24 V 4 6 8 10 12 14 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 3900 min-1 700 1.5 400 300 1.0 200 0.5 100 0 (m3/min) 4000 Airflow 20.4 V 2000 1000 4 6 8 10 12 14 0 2 0 100 200 300 400 500 (CFM) 0 (m3/min) 100 (%) PWM duty cycle PWM Airflow With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) DC48 V 48 VDC 0 100 200 300 400 500 600 Static pressure 1200 4.5 1100 4.0 1000 PWM PWM duty cycle 3.5 900 100% 800 3.0 700 2.5 600 50% 2.0 500 1.5 400 300 1.0 200 0.5 100 0 3 0 2 4 6 8 10 12 14 16 18 (m /min) PWM duty - Speed characteristics example 1200 4.5 1100 4.0 1000 55.2 V 3.5 900 800 48 V 3.0 700 2.5 600 36 V 2.0 500 1.5 400 300 1.0 200 0.5 100 0 0 2 4 6 8 10 12 14 16 18 (m3/min) 0 100 200 300 400 500 600 (CFM) Airflow Airflow (min-1) PWM duty cycle 100% PWM100% (CFM) 5000 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 4700 min-1 4000 3000 DC PWM duty cycle 2000 1000 0 Centrifugal Fan o175 mm 9TG48P0G01 Static pressure (min-1) 800 Fan speed 0 PWM duty cycle 100% PWM100% 3.0 700 Static pressure Static pressure 3.0 (inch H2O) (Pa) 24 VDC DC24 V 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 100 (%) PWM duty cycle PWM Dimensions (unit: mm) 691 60.51 +30 300 0 (10) 1 45 271 o1751 o1311 46.81 Airflow direction Lead wire AWG22 (Model: 9TG24P0G01 9TG24P0G01) AWG22 AWG24 (Model: 9TG24P0S01, AWG24 9TG48P0G01 9TG48P0G01) UL 1430 4-M4 0.3 o77.81 8 o5 Airflow direction Rotating direction 441 o1 58 o14 0 8 0.5 .5 Inlet nozzle side 4-o 4-o 4.5o 4.5 15 8 0. 5 o14 8 0.5 45 4-o4.5 o580.5 45 Reference Diagram for Mounting Inlet nozzle Finger guard (14) 0.5 Fan side (2) 4-o4.5 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan Bolt length: 4 to 6 mm. 4 mm6 mm To prevent bolts from loosening, use plain washers and spring washers. Options Finger guards Model no.: 109-722, 109-722H 442 page: p. 533 Inlet nozzle Model no.: 109-1073, 109-1073H page: p. 537 Centrifugal Fan o 221x71 mm San Ace C221 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 1050 g Specifications When the optional inlet nozzle (109-1135) is mounted. [V] [V] 24 9TP24P0H001 16 to 36 9TP48P0G001 48 36 to 72 9TP48P0H001 PWM duty cycle* [%] Rated current Rated input Rated speed [A] 100 15 100 15 100 15 3.2 0.4 2.75 0.2 1.6 0.2 Max. airflow Max. static pressure [W] [min-1] [m/min] [CFM] [Pa] 76.8 9.6 132 9.6 76.8 9.6 3050 1000 3650 1000 3050 1000 17.6 5.75 21 5.75 17.6 5.75 622 203 742 203 622 203 530 57.4 760 57.4 530 57.4 [inchHO] 2.13 0.23 3.05 0.23 2.13 0.23 SPL Operating temperature Expected life [dB (A)] [C] [h] 71 53 74 53 71 53 -20 to +70 -20 to +60 40000/60C (70000/40C) -20 to +70 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9TP48P0G001: 280 W, 9TP24P0H001/9TP48P0H001: 160 W at rated voltage. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 578. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 2.5 600 3.0 PWM duty cycle PWM Static pressure Static pressure 3.0 (inch H2O) (Pa) 24 VDC DC24 V 800 100% 2.0 1.5 1.0 400 200 0.5 0 0 0 15% 2.5 1.0 (min-1) PWM duty cycle 100% PWM100% 800 5000 24 V/36 V 400 16 V 200 10 200 400 15 600 Airflow 20 25 (m3/min) 800 (CFM) 0 0 0 3000 3050 min-1 2000 1000 0.5 5 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 600 2.0 1.5 PWM duty - Speed characteristics example Fan speed 9TP24P0H001 5 10 200 400 15 600 Airflow 20 25 (m3/min) 800 (CFM) 0 100 (%) PWM duty cycle PWM 443 Centrifugal Fan o221 mm Rated voltage Operating voltage range Model no. DC The models listed below have pulse sensors with PWM control function. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9TP48P0G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 100% 600 2.0 1.5 1.0 400 200 15% 0.5 0 0 0 9TP48P0H001 5 10 200 400 15 20 600 (CFM) 3.0 PWM PWM duty cycle 100% 600 400 200 0 0 0 36 V 400 200 0 5 10 0 200 400 15% 20 600 25 (m3/min) 800 3000 2000 0 100 (%) PWM duty cycle PWM (CFM) 5 10 200 2.5 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 800 600 5000 2.0 1.5 1.0 400 15 400 20 600 25 (m3/min) 800 Airflow 0 36 V 200 0 0 (CFM) 711 63.51 1 +30 300 0 45 64.91 4-M4 o5 Airflow direction 8 0.3 o1041 Rotating direction 3000 3050 min-1 2000 1000 5 10 200 400 15 600 Airflow Lead wire AWG20 AWG22 AWG20or AWG22 271 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 4000 48 V/72 V 0.5 Airflow direction o2211 o1611 15 Airflow Dimensions (unit: mm) 444 3650 min-1 1000 (inch H2O) (Pa) 48 VDC DC48 V 800 0.5 4000 600 Operating voltage range Static pressure Static pressure 1.0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function 2.0 1.5 1.0 0 25 (m3/min) 800 Airflow (inch H2O) (Pa) 2.5 48 V/72 V 2.0 1.5 5000 0.5 PWM duty cycle 3.0 2.5 (min-1) PWM duty cycle 100% PWM100% 800 Fan speed 2.5 3.0 PWM duty cycle PWM Static pressure Static pressure 3.0 (inch H2O) (Pa) 48 VDC DC48 V 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 20 25 (m3/min) 800 (CFM) 0 100 (%) PWM duty cycle PWM Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) o2 45 4-o 4.5 02 Reference Diagram for Mounting Bracket-mounted model of this fan is available. For details, refer to pp. 448 to 450. Inlet nozzle Fan Bolt length: 6 mm mm max. Options Finger guards Model no.: 109-1138 page: p. 535 Inlet nozzle page: p. 537 Model no.: 109-1135 445 Centrifugal Fan o221 mm DC (21) (2) Finger guard 5 0. o2 45 o580.5 Inlet nozzle side .5 4-o4.5 0.5 0 45 Fan side Centrifugal Fan o 225x99 mm San Ace C225 9T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 1220 g Specifications When the optional inlet nozzle (109-1134) is mounted. The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 9TS48P0G001 48 36 to 72 9TS48P0H001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 100 15 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.65 0.24 2.08 0.24 175.2 11.5 99.8 11.5 3550 1000 2900 1000 28.1 7.85 22.7 7.85 992 277 802 277 861 68.5 590 68.5 [inchHO] 3.46 0.28 2.37 0.28 SPL Operating temperature Expected life [dB (A)] [C] [h] 74.5 52.0 70.5 52.0 -20 to +60 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9TS48P0G001: 380 W, 9TS48P0H001: 200 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function Operating voltage range 3.0 2.5 PWM PWM duty cycle 100% 800 600 2.0 1.5 1.0 0.5 0 400 200 0 0 15% 5 Airflow 0 100% 400 0 446 3.0 PWM duty cycle PWM 0 15% 5 1.0 400 0 2000 1000 200 5 10 15 20 25 30 (m3/min) 200 400 600 800 1000 Airflow (inch H2O) (Pa) 48 VDC DC48 V 0.5 36 V 0 100 (%) PWM duty cycle PWM (CFM) Operating voltage range 800 200 3550 min-1 3000 600 0 Static pressure Static pressure 1.0 1.5 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 48 V/72 V 800 2.0 (CFM) 2.0 1.5 4000 With pulse sensor with PWM control function (inch H2O) (Pa) 600 2.5 0 10 15 20 25 30 (m3/min) PWM duty cycle 2.5 3.0 0.5 200 400 600 800 1000 9TS48P0H001 3.0 3.5 (min-1) PWM duty cycle 100% PWM100% 4.0 1000 Static pressure Static pressure 3.5 (inch H2O) (Pa) 48 VDC DC48 V 4.0 1000 Fan speed (inch H2O) (Pa) PWM duty - Speed characteristics example 10 15 20 25 600 1.0 4000 3000 48 V/72 V 2.0 1.5 (min-1) PWM duty cycle 100% PWM100% 800 400 36 V Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 2900 min-1 2000 1000 200 0.5 30 (m3/min) 200 400 600 800 1000 Airflow 2.5 PWM duty - Speed characteristics example Fan speed 9TS48P0G001 PWM duty cycle (CFM) 0 0 0 5 10 15 20 25 30 (m3/min) 200 400 600 800 1000 Airflow (CFM) 0 100 (%) PWM duty cycle PWM Dimensions (unit: mm) +30 300 0 991.5 90.41.5 (10) AWG20 UL 3266 45 Airflow direction Lead wire 4-M4 64.91 +2 o153 0 o225 0 +2 271 o5 8 0.3 o1041 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Fan side Inlet nozzle side 10 o2 00 4-o4 .5 0 5 0. o2 .5 4-o4.5 Reference Diagram for Mounting Centrifugal Fan o225 mm 0.5 DC 45 o58 Bracket-mounted model of this fan is available. For details, refer to pp. 451 to 452. (29.5) (3.5) Inlet nozzle Finger guard Fan Bolt length:66mm mm max. Options Finger guards Model no.: 109-1137 page: p. 535 Inlet nozzle page: p. 537 Model no.: 109-1134 447 Bracket-mounted Centrifugal Fan 270x270x99 mm San Ace C270 9B1T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Bracket: Aluminum, Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 1700 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 24 9B1TP24P0H001 16 to 36 9B1TP48P0G001 48 36 to 72 9B1TP48P0H001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 100 15 100 15 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.2 0.4 2.75 0.2 1.6 0.2 76.8 9.6 132 9.6 76.8 9.6 3050 1000 3650 1000 3050 1000 17.6 5.75 21.0 5.75 17.6 5.75 622 203 742 203 622 203 530 57.4 760 57.4 530 57.4 [inchHO] 2.13 0.23 3.05 0.23 2.13 0.23 SPL Operating temperature Expected life [dB (A)] [C] [h] 71 53 74 53 71 53 -20 to +70 -20 to +60 40000/60C (70000/40C) -20 to +70 * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9B1TP24P0H001/9B1TP48P0H001: 160 W, 9B1TP48P0G001: 280 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 2.5 600 2.0 1.5 400 1.0 200 0.5 0 0 0 448 3.0 PWM PWM duty cycle 100% Static pressure Static pressure 3.0 (inch H2O) (Pa) 24 VDC DC24 V 800 15% 5 200 PWM duty - Speed characteristics example (min-1) PWM100% PWM duty cycle 100% 800 2.5 600 5000 2.0 1.5 400 1.0 16 V 200 400 15 600 Airflow 20 25 (m3/min) 800 (CFM) 0 0 0 3000 3050 min-1 2000 1000 0.5 10 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 24 V/36 V Fan speed 9B1TP24P0H001 5 200 10 400 15 600 Airflow 20 25 (m3/min) 800 (CFM) 0 100 (%) PWM duty cycle PWM Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9B1TP48P0G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 3.0 PWM duty cycle PWM 100% 2.5 600 Static pressure 2.0 1.5 400 15% 0 0 5 0 200 9B1TP48P0H001 10 15 400 20 600 Static pressure Static pressure PWM duty cycle PWM 100% 15% 5 0 200 5 10 200 (inch H2O) (Pa) 3.0 0 3000 2000 1000 400 15 20 600 25 (m3/min) 800 Airflow 0 100 (%) PWM duty cycle PWM (CFM) Operating voltage range 1.5 400 0 0 0 48 VDC DC48 V 200 200 3650 min-1 With pulse sensor with PWM control function 800 0.5 36 V 1.5 400 (CFM) 2.0 1.0 2.0 0 25 (m3/min) 800 Airflow (inch H2O) (Pa) 2.5 600 4000 0.5 PWM duty cycle 3.0 48 V/72 V 2.5 600 1.0 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 800 2.5 600 5000 4000 48 V/72 V 2.0 1.5 400 1.0 36 V 200 15 400 20 600 Airflow 0 25 (m3/min) 800 0 0 (CFM) 3050 min-1 3000 2000 1000 0.5 10 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 DC 200 0.5 5000 5 200 10 400 15 20 600 Airflow 25 (m3/min) 800 (CFM) 0 Centrifugal Fan 270 mm sq. 1.0 (min-1) PWM duty cycle 100% PWM100% 800 Fan speed Static pressure 3.0 (inch H2O) (Pa) 48 VDC DC48 V 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 100 (%) PWM duty cycle PWM 05 4-o50.2 45 o3 2701 921 hole part 70.5 Mounting +1.5 7 -0.5 4-o50.2 Airflow direction 2202 97.80.3 73.10.3 97.80.3 0 .5 Dimensions (unit: mm) 55 Rotating direction .2 Airflow direction 73.10.3 73.10.3 228 o1 +30 245 0 (10) 2 2 2701 2202 97.80.3 73.10.3 90 Lead wire AWG 22 UL 3266 97.80.3 Rotating direction 449 0 05 o3 5 4-o (E 247.50.5 247.50.5 45 ac h) Inlet panel side .5 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) o294.50.5 Reference Diagram for Mounting Finger guard 109-1146 should be mounted with four holes as in the drawing. Finger guard Fan Options Finger guards Model no.: 109-1146 450 page: p. 536 Bracket-mounted Centrifugal Fan 270x270x119 mm San Ace C270 9B1T type General Specifications Material ................................................ Motor case: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-0) Bracket: Aluminum, Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and motor case) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and motor case) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 1920 g Specifications [V] [V] 9B1TS48P0G001 48 36 to 72 9B1TS48P0H001 PWM duty cycle* [%] Rated current Rated input Rated speed 100 15 100 15 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.65 0.24 2.08 0.24 175.2 11.5 99.8 11.5 3550 1000 2900 1000 28.1 7.85 22.7 7.85 992 277 802 277 861 68.5 590 68.5 [inchHO] 3.46 0.28 2.37 0.28 SPL Operating temperature Expected life [dB (A)] [C] [h] 74.5 52.0 70.5 52.0 -20 to +60 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. Max input of 9B1TS48P0G001: 380 W, 9B1TS48P0H001: 200 W at rated voltage. Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9B1TS48P0G001 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 1000 800 3.0 2.5 600 2.0 400 1.5 1.0 200 0.5 0 0 0 15% 5 3.0 Static pressure Static pressure 0 1.5 400 200 15% 5 2000 1000 200 0 5 0 200 400 600 800 1000 10 15 20 25 30 (m3/min) Airflow (inch H2O) (Pa) 2.0 0 1.0 0 100 (%) PWM duty cycle PWM (CFM) Operating voltage range PWM PWM duty cycle 100% 0.5 36 V With pulse sensor with PWM control function 48 VDC DC48 V 2.5 600 3550 min-1 400 Airflow 800 0 600 1.5 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 3000 2.0 200 400 600 800 1000 (CFM) (inch H2O) (Pa) 0 2.5 10 15 20 25 30 (m3/min) 9B1TS48P0H001 1.0 3.0 4000 48 V/72 V 800 0.5 PWM duty cycle 3.0 3.5 (min-1) PWM100% PWM duty cycle 100% 1000 4.0 PWM PWM duty cycle 100% Static pressure Static pressure 3.5 (inch H2O) (Pa) 48 VDC DC48 V Airflow 4000 3000 48 V/72 V 2.0 1.5 400 36 V 200 Voltage: 48 VDC DC48 V PWM frequency:kHz 25 kHz PWM25 2900 min-1 2000 1000 0.5 10 15 20 25 30 (m3/min) 200 400 600 800 1000 (min-1) PWM duty cycle 100% PWM100% 800 2.5 600 1.0 PWM duty - Speed characteristics example Fan speed 4.0 PWM duty - Speed characteristics example Fan speed PWM duty cycle (CFM) 0 0 0 5 10 15 20 25 30 (m3/min) 200 400 600 800 1000 Airflow (CFM) 0 100 (%) PWM duty cycle PWM 451 Centrifugal Fan 270 mm sq. Rated voltage Operating voltage range Model no. DC The models listed below have pulse sensors with PWM control function. 2701 45 4-o50.2 2202 97.80.3 73.10.3 Airflow direction Airflow direction 73.10.3 28 46 73.10.3 Rotating direction Rotating direction 0 05 5 4-o (E 45 ac h) 247.50.5 247.50.5 o3 Inlet panel side .5 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) o294.50.5 Reference Diagram for Mounting Finger guard 109-1146 should be mounted with four holes as in the drawing. Finger guard Fan Options Finger guards Model no.: 109-1146 452 page: p. 536 2- o1 2 2 2701 2202 97.80.3 73.10.3 90 1121 hole part 70.5 Mounting +1.5 7 -0.5 97.80.3 4-o50.2 o3 05 0 .5 Dimensions (unit: mm) 97.80.3 Lead wire AWG 20 UL 3266 +30 245 0 (10) Blower Cooling fan specialized for high static pressure. Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 109B C 12 H C 2 -1 Type name Frame size Voltage Speed code Sensor specifications Frame thickness Individual customer s spec 9B MB 12 G 2 01 -1 Type name Frame size Voltage Speed code Frame thickness Sensor specifications Individual customer s spec P 2 G Fans with PWM control function Type name MB 12 Frame size Voltage Type name 109B Frame size (mm) PWM control function Frame thickness 01 Speed code Individual customer s spec (2 to 3 digits) 9B C D F, FB G J M, MB, MC 52 76 120 160 127 97 Voltage (V) 12 12 Speed code F Sensor specifications A, 02 C, 01 D Without a sensor With a pulse sensor With a lock sensor Frame thickness (mm) 1 40 G H etc. K M S 2 30, 32, 33 DC 24 24 7 15 Blower 9B 6 20 How to Read Specifications (DC fan) Model no. 9GA0412G70 01 Rated voltage Operating voltage range Rated current Rated input Rated speed [V] 12 Rated voltage ..................... Operating voltage range ...... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ [V] 7 to 13.8 [A] 0.17 [W] 2.04 [min-1] 13100 Max. airflow [m/min] 0.36 [CFM] 12.7 Max. static pressure [Pa] 192 [inchHO] 0.77 SPL Operating temperature [dB (A)] [C] [h] -20 to +70 40000/60C (70000/40C) 42 Expected life This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC The voltage range over which fan operation is guaranteed. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. Expected life at 40C is for reference only. For more information, please refer to the technical material section. 453 Blower 52x15 mm San Ace B52 9BC type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 33 g Specifications The models listed below have pulse sensors. Operating voltage range Rated current Rated input Rated voltage Model no. [V] 109BC12GC7-1 109BC12HC7-1 109BC12FC7-1 109BC12MC7-1 109BC24GC7-1 109BC24HC7-1 109BC24FC7-1 [V] 12 6 to 13.8 24 12 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.12 0.1 0.08 0.06 0.07 0.05 0.04 1.44 1.2 0.96 0.72 1.68 1.2 0.96 6200 5600 5100 4600 6200 5600 5100 0.125 0.112 0.101 0.091 0.125 0.112 0.101 4.4 4.0 3.6 3.2 4.4 4.0 3.6 215 165 130 100 215 165 130 [inchHO] 0.86 0.66 0.52 0.4 0.86 0.66 0.52 SPL Operating temperature Expected life [dB (A)] [C] [h] 43 40 38 35 43 40 38 -20 to +70 40000/60C (70000/40C) The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109BC12HC7-1 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 220 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 12 V 0.6 160 0.4 0.2 120 80 6V 40 0 0 0.04 0.08 0.12 0.16 (m3/min) 1.0 2.0 3.0 4.0 5.0 Airflow (CFM) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 13.8 V 12 V 6V 0.02 0.04 0.06 0.08 0.1 0.12 0.14 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 (CFM) Airflow With pulse sensor Operating voltage range 260 240 220 200 180 160 140 120 100 80 60 40 20 0 Static pressure Static pressure 0.8 200 0 454 13.8 V 109BC12FC7-1 (inch H2O) (Pa) 280 1.0 240 With pulse sensor Static pressure 109BC12GC7-1 13.8 V 12 V 6V 0.02 0.04 0.06 0.08 0.1 0.12 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 (CFM) Airflow Airflow - Static Pressure Characteristics 109BC24GC7-1 With pulse sensor Operating voltage range Operating voltage range 280 1.0 240 0.3 80 60 0.2 40 0.1 20 0 0 Static pressure Static pressure (inch H2O) (Pa) 0.7 180 160 0.6 140 0.5 120 13.8 V 12 V 6V Airflow 109BC24FC7-1 24 V 160 120 80 12 V 0.2 40 0 0.02 0.04 0.06 0.08 0.1 0.12 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 0.4 Operating voltage range 27.6 V 0.8 200 0.6 0 0 (CFM) With pulse sensor (inch H2O) (Pa) (inch H2O) (Pa) 0.4 100 109BC24HC7-1 With pulse sensor Static pressure 109BC12MC7-1 0.04 0.08 0.12 0.16 (m3/min) 1.0 2.0 3.0 4.0 5.0 Airflow 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 260 240 220 200 180 160 140 120 100 80 60 40 20 0 27.6 V 24 V 12 V 0.02 0.04 0.06 0.08 0.1 0.12 0.14 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 (CFM) (CFM) Airflow With pulse sensor Operating voltage range 220 0.8 200 0.7 180 160 0.6 140 0.5 120 0.4 100 0.3 80 60 0.2 40 0.1 20 0 0 27.6 V 24 V 12 V 0.02 0.04 0.06 0.08 0.1 0.12 DC Static pressure (inch H2O) (Pa) (m3/min) Blower 52 mm 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 (CFM) Airflow Dimensions (unit: mm) 24.71 (1.2) 28.21 AIRFLOW 1 2 230.3 200.3 52.61 (2) 19.91 (8) (4) (1.2) (17.5) (0.8) 150.5 30030 (10) o3 Rotating direction Lead wire AWG26 UL 1061 .3 0 le 4.5 gho o 2- in t un o 180.3 200.3 511 M Airflow direction 455 Blower 76x20 mm San Ace B76 9BD type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Mass ...................................................... 58 g Specifications The models listed below have pulse sensors. Rated voltage Model no. Operating voltage range Rated current Rated input 9BD12SC6-1 9BD12HC6-1 9BD12FC6-1 9BD24SC6-1 9BD24HC6-1 9BD24FC6-1 12 24 Rated speed Max. airflow Max. static pressure [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 5 to 13.8 0.28 0.21 0.18 0.14 0.12 0.1 3.36 2.52 2.16 3.36 2.88 2.4 4500 4200 3900 4500 4200 3900 0.29 0.27 0.25 0.29 0.27 0.25 10.2 9.5 8.8 10.2 9.5 8.8 300 230 200 300 230 200 [V] 5.5 to 13.8 10 to 27.6 [inchHO] 1.2 0.92 0.8 1.2 0.92 0.8 SPL Operating temperature Expected life [dB (A)] [C] [h] 43 41 39 43 41 39 -20 to +70 40000/60C (70000/40C) The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 566. PWM control Airflow - Static Pressure Characteristics 9BD12SC6-1 9BD12HC6-1 With pulse sensor Operating voltage range 9BD12FC6-1 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) 1.4 350 1.2 300 1.4 350 1.2 300 13.8 V 1.0 250 12 V 0.8 200 0.6 150 0.4 100 0.2 50 0 0 5V 0.05 0.1 0.15 0.2 0.25 0.3 0.35 456 0.8 200 (m3/min) 12 V 0.6 150 0.4 100 0.2 50 0 1 2 3 4 5 6 7 8 9 10 11 12 13 (CFM) Airflow 1.0 250 13.8 V Static pressure Static pressure (inch H2O) (Pa) 1.6 400 Static pressure (inch H2O) (Pa) 1.2 300 0 0 5.5 V 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0 1 2 3 4 5 6 7 8 9 10 111213 Airflow With pulse sensor (m3/min) (CFM) 1.0 250 13.8 V 0.8 200 12 V 0.6 150 0.4 100 0.2 50 0 0 5.5 V 0.05 0.1 0.15 0.2 0.25 0.3 (m3/min) 0 1 2 3 4 5 6 7 8 9 10 11 (CFM) Airflow Airflow - Static Pressure Characteristics 9BD24SC6-1 9BD24HC6-1 With pulse sensor Operating voltage range 9BD24FC6-1 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 1.6 400 1.4 350 1.2 300 1.2 300 27.6 V 1.0 250 24 V 0.8 200 0.6 150 0.4 100 10 V 0.2 50 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 27.6 V 1.0 250 Static pressure 1.2 300 Static pressure Static pressure 1.4 350 24 V 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (m3/min) 10 V 0.05 0.1 0.15 0.2 0.25 0.3 0.35 1.0 250 24 V 0.6 150 0.4 100 0.2 50 0 0 (m3/min) 10 V 0.05 0.1 0.15 0.2 0.25 0.3 (m3/min) 0 1 2 3 4 5 6 7 8 9 10 11 (CFM) Airflow Airflow Airflow 27.6 V 0.8 200 0 1 2 3 4 5 6 7 8 9 10 111213 (CFM) 0 1 2 3 4 5 6 7 8 9 10 11 1213 (CFM) With pulse sensor 310.3 AIRFLOW (10 ) 260.3 DC Blower 76 mm 1 o42 0 30 2-o4.50.3 hole Mounting 761 (1.5) (10) 260.3 30 (12) (1.2) 24.91 Lead wire AWG26 UL 1007 32.11 42.21 (1.4) (1.2) (10) (12) 201 (1.2) (1.5) Dimensions (unit: mm) 310.3 69.71 Rotating direction Airflow direction 457 Blower 76x30 mm San Ace B76 9BD type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 100 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Model no. [V] 109BD12HC2 109BD12FC2 109BD12MC2 109BD24HC2 109BD24FC2 109BD24MC2 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.37 0.27 0.14 0.17 0.14 0.1 4.44 3.24 1.68 4.08 3.36 2.4 3000 2600 2100 3000 2600 2100 0.36 0.31 0.25 0.36 0.31 0.25 12.7 10.9 8.8 12.7 10.9 8.8 151.9 98 58.8 151.9 98 58.8 SPL [inchHO] Operating temperature Expected life [dB (A)] [C] 41.5 37 32.5 41.5 37 32.5 -20 to +60 0.61 0.394 0.236 0.61 0.394 0.236 [h] -20 to +70 40000/60C -20 to +60 -20 to +70 The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 561. PWM control Airflow - Static Pressure Characteristics 109BD12HC2 109BD12FC2 With pulse sensor Operating voltage range Operating voltage range 0.6 0.6 13.8 V 150 12 V 10.2 V 0.5 0.4 Static pressure Static pressure 0.7 100 0.3 0.2 50 0 0.1 0 458 0.4 0.5 0.4 13.8 V 100 12 V 0.3 0.2 10.2 V 50 0.1 0.1 0 (inch H2O) (Pa) 150 Static pressure 200 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) 0 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.8 109BD12MC2 With pulse sensor 0 0.1 0 2 4 0.2 6 0.3 0.4 (m3/min) 8 10 12 14 Airflow (CFM) 100 13.8 V 0.3 12 V 0.2 50 10.2 V 0.1 0 0 0.1 0 2 4 0.3 0.2 6 Airflow 8 10 (m3/min) 12 (CFM) Airflow - Static Pressure Characteristics 109BD24HC2 109BD24FC2 With pulse sensor Operating voltage range Operating voltage range 0.6 0.6 27.6 V 150 24 V 20.4 V 0.5 0.4 Static pressure Static pressure 0.7 100 0.3 0.2 50 0.4 0.5 0.4 27.6 V 100 24 V 0.3 0.2 20.4 V 50 0.1 0.1 0 (inch H2O) (Pa) 150 Static pressure 200 0 0.1 0 2 4 0.2 6 0.3 0 0.4 (m3/min) 8 10 12 14 Airflow 0 0.1 0 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 0.8 109BD24MC2 With pulse sensor 2 4 0.2 6 0.3 Airflow 27.6 V 0.3 24 V 0.2 50 20.4 V 0.1 0 0.4 (m3/min) 8 10 12 14 100 0 0.1 0 (CFM) 2 4 0.3 0.2 6 Airflow 8 10 (m3/min) 12 (CFM) Lead wire AWG24 UL 1007 24.10.3 AIRFLOW o47 2-o4.50.3 Mounting hole DC 21.60.3 Blower 76 mm (36) 75.51 +50 300 0 (10) Rotating direction (38) (10) (10) 36.20.3 (2) 400.3 300.5 (2) (2.5) 30.90.3 761 (1.5) Dimensions (unit: mm) Airflow direction 459 Blower 97x33 mm San Ace B97 9BMC type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown Mass ...................................................... 200 g Specifications The models listed below have pulse sensors with PWM control function. Rated voltage Operating voltage range Model no. [V] [V] 12 9BMC12P2G001 10.8 to 13.2 24 9BMC24P2G001 21.6 to 26.4 PWM duty cycle* [%] Rated current Rated input Rated speed 100 20 100 20 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 6.2 0.38 3.1 0.19 74.4 4.56 74.4 4.56 8200 2800 8200 2800 1.85 0.58 1.85 0.58 65.3 20.4 65.3 20.4 1950 121.0 1950 121.0 [inchHO] 7.83 0.48 7.83 0.48 SPL Operating temperature Expected life [dB (A)] [C] [h] 69 44 69 44 -20 to +70 40000/60C (70000/40C) * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 567. Without sensor Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 8 2000 100% 6 1500 5 4 1000 60% 3 2 500 20% 1 0 0 0.5 PWM duty cycle 100% PWM100% (min-1) 12 V/13.2 V 8000 7 Static pressure Static pressure 8 2000 PWM PWM duty cycle 7 9000 10.8 V 5 4 1000 3 2 1.0 1.5 2.0 (m3/min) Airflow (CFM) 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 8200 min-1 7000 6 1500 500 6000 5000 4000 3000 2000 1 0 10 20 30 40 50 60 70 460 (inch H2O) (Pa) 12 VDC DC12 V PWM duty - Speed characteristics example Fan speed 9BMC12P2G001 1000 0 0.5 1.0 1.5 2.0 0 10 20 30 40 50 60 70 Airflow (m3/min) (CFM) 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example With pulse sensor with PWM control function PWM duty cycle Operating voltage range (inch H2O) (Pa) 8 2000 PWM duty cycle PWM 7 6 1500 5 4 1000 60% 3 2 500 20% 1 0 0 0.5 9000 24 V/26.4 V 7000 21.6 V 5 4 1000 3 500 1.0 1.5 0 2.0 (m3/min) 0 0.5 1.0 1.5 2.0 4000 3000 100 (%) 0 (m3/min) PWM PWM duty cycle (CFM) Airflow Airflow 5000 1000 0 10 20 30 40 50 60 70 (CFM) 6000 2000 1 0 10 20 30 40 50 60 70 8200 min-1 8000 6 1500 2 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 (min-1) PWM duty cycle 100% PWM100% 7 100% Static pressure Static pressure (inch H2O) (Pa) 24 VDC DC24 V 8 2000 PWM duty - Speed characteristics example Fan speed 9BMC24P2G001 (52) 30 (10) 390.3 31.50.3 AIR FLOW 4-o4.50.3 Mounting hole o56 1 DC 0 (21) 97.11 .2 R51 (10 ) (5) Blower 97 mm (1 8. 6) 30 (8) AWG 24 UL 1430 (58) Rated voltage 24 V fan 24 V (1.5) AWG 20 UL 1430 (50) 390.3 450.3 951 (1 8. Lead wire Rated voltage 12 V fan 12 V (1.5) 390.3 320.3 1 .6 6) R59 331 (2.4) (1.5) Dimensions (unit: mm) 260.3 320.3 1 Rotating direction Airflow direction 461 Blower 97x33 mm San Ace B97 9BMB type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Control Brown (For models without PWM control function, there is no speed control wiring.) Mass ...................................................... 190 g Specifications The models listed below have pulse sensors with PWM control function. Model no. 9BMB12P2K01 9BMB12P2G01 9BMB12P2S01 9BMB12P2H01 9BMB12P2F01 9BMB24P2K01 9BMB24P2G01 9BMB24P2S01 9BMB24P2H01 9BMB24P2F01 Rated voltage Operating voltage range [V] [V] PWM duty cycle* [%] 10.8 to 13.2 12 24 10.2 to 13.8 21.6 to 26.4 100 100 100 100 100 100 100 100 100 100 Rated current Rated input Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 3.4 1.8 1.4 1.1 0.9 1.62 0.83 0.7 0.55 0.45 40.8 21.6 16.8 13.2 10.8 38.88 19.92 16.8 13.2 10.8 6850 5750 5250 4850 4500 6850 5750 5250 4850 4500 1.61 1.34 1.22 1.11 1.04 1.61 1.34 1.22 1.11 1.04 56.8 47.3 43.1 39.2 36.7 56.8 47.3 43.1 39.2 36.7 1280 760 610 490 410 1280 760 610 490 410 [inchHO] 5.14 3.05 2.45 1.968 1.64 5.14 3.05 2.45 1.968 1.64 SPL Operating temperature Expected life [dB (A)] [C] [h] 66 61 59 57 56 66 61 59 57 56 -20 to +70 40000/60C * PWM frequency: 25 kHz. Fan does not rotate when PWM duty cycle is 0%. The following sensor and control options are available for selection. Available for all models. Without sensor Pulse sensor Differs according to the model. Refer to the table on pp. 566 to 567. Lock sensor The models listed below have pulse sensors. Model no. 9BMB12K201 9BMB12G201 9BMB12S201 9BMB12H201 9BMB12F201 9BMB24K201 9BMB24G201 9BMB24S201 9BMB24H201 9BMB24F201 Rated voltage Operating voltage range Rated current Rated input Rated speed 12 [A] [W] [min-1] [m/min] 7 to 13.2 3.4 1.8 1.4 1.1 0.9 1.62 0.83 0.7 0.55 0.45 40.8 21.6 16.8 13.2 10.8 38.88 19.9 16.8 13.2 10.8 6850 5750 5250 4850 4500 6850 5750 5250 4850 4500 1.61 1.34 1.22 1.11 1.04 1.61 1.34 1.22 1.11 1.04 7 to 13.8 21.6 to 26.4 24 12 to 26.4 The following sensor and control options are available for selection. Available for all models. Without sensor PWM control Differs according to the model. Refer to the table on pp. 566 to 567. Lock sensor 462 Max. airflow [V] [V] [CFM] 56.8 47.3 43.1 39.2 36.7 56.8 47.3 43.1 39.2 36.7 Max. static pressure [Pa] 1280 760 610 490 410 1280 760 610 490 410 [inchHO] 5.14 3.052 2.45 1.968 1.647 5.14 3.052 2.45 1.968 1.647 SPL Operating temperature Expected life [dB (A)] [C] [h] 66 61 59 57 56 66 61 59 57 56 -20 to +70 40000/60C Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9BMB12P2K01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 5.0 1200 4.0 1000 800 60% 600 400 0.5 1.0 1.5 2.0 (m3/min) 10 20 30 40 50 60 70 Static pressure 50% 0 0.4 10 0.8 20 30 1.2 40 50 Airflow Static pressure 0.5 0 PWM PWM duty cycle 100% 400 50% 0.4 10 0.8 Static pressure 200 0 0 0 3.0 20 30 50 40 Airflow 0.4 10 0.8 20 1.2 30 40 Airflow 1.6 (m3/min) 50 3000 2000 0 100 (%) PWM PWM duty cycle (CFM) PWM duty - Speed characteristics example 6000 13.8 V 12 V 1.5 400 10.2 V 200 0 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5250 min-1 5000 2.0 1.0 (min-1) PWM duty cycle 100% PWM100% 800 (CFM) 4000 3000 2000 1000 0.4 1.2 0.8 20 10 30 40 Airflow 1.6 (m3/min) 50 0 100 (%) PWM PWM duty cycle (CFM) Operating voltage range (inch H2O) (Pa) 12 VDC DC12 V 3.0 PWM PWM duty cycle 100% 2.0 400 50% (min-1) PWM duty cycle 100 PWM100% 800 6000 5000 2.5 600 13.8 V 2.0 12 V 1.5 400 1.0 PWM duty - Speed characteristics example 10.2 V 200 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 0 0 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4850 min-1 4000 3000 2000 1000 0.5 0.5 0 4000 With pulse sensor with PWM control function 800 0 5750 min-1 1000 2.5 600 0 1.6 (m3/min) 1.2 2.5 600 0 10.2 V 1.0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 5000 400 1.5 0.5 (inch H2O) (Pa) 200 6000 12 V 2.0 200 9BMB12P2H01 1.0 (min-1) 13.8 V 1000 PWM duty cycle 1.5 100 (%) PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 600 3.5 600 0 0 PWM PWM duty cycle Airflow (inch H2O) (Pa) 12 VDC DC12 V 800 0 3.0 2.5 (CFM) 2.0 1.0 2.0 (m3/min) Operating voltage range 1000 1.5 1.5 With pulse sensor with PWM control function (inch H2O) (Pa) 2.5 1.0 10 20 30 40 50 60 70 (CFM) 800 3.0 1.6 (m3/min) PWM duty cycle 3.0 3.5 0.5 9BMB12P2S01 3.5 0.5 0 200 0 1000 1000 PWM PWM duty cycle 100% 800 2.5 600 2.0 1.5 400 0 2000 (inch H2O) (Pa) 12 VDC DC12 V 1000 0.5 3000 200 Operating voltage range (inch H2O) (Pa) 1.0 4000 With pulse sensor with PWM control function PWM duty cycle 3.0 5000 400 0 (CFM) Airflow 9BMB12P2G01 3.5 0 6850 min-1 DC 0 2.0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 0 100 (%) PWM PWM duty cycle 463 Blower 97 mm 0 10.8 V Fan speed 0 12 V 600 1.0 20% 13.2 V Fan speed 200 6000 Fan speed 1.0 7000 1200 800 3.0 8000 1400 4.0 1000 Static pressure 2.0 5.0 Static pressure 3.0 Static pressure PWM PWM duty cycle 100% (min-1) PWM duty cycle 100% PWM100% 1600 6.0 1400 Static pressure Static pressure 6.0 (inch H2O) (Pa) DC12 V 12 VDC 1600 PWM duty - Speed characteristics example Fan speed PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9BMB12P2F01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) PWM duty cycle PWM 100% 400 60% 0.5 100 0 0 0.4 10 9BMB24P2K01 0.8 20 30 1.2 40 1.6 50 Airflow 0 (m3/min) 0 6.0 1400 PWM duty cycle PWM 100% 1200 800 60% 600 400 0.5 1.0 1.5 Airflow Static pressure Static pressure 33 50% 50% 3 3 (m(m /min) /min) 0.40.4 0.80.8 1.21.2 1.61.6 9BMB24P2S01 Static pressure 24 V 800 21.6 V 600 00 3000 2000 1000 0.5 1.0 1.5 2.0 (m3/min) 0 100 (%) PWM PWM duty cycle 10 20 30 40 50 60 70 (CFM) Airflow PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% PWM100% 7000 26.4 VV 26.4 800 800 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 6000 2424 VV 21.6 VV 21.6 200 200 5750 min-1 5000 4000 3000 2000 1000 00 3 3 (m(m /min) /min) 0.40.4 0.80.8 1.21.2 1.61.6 Airflow 0 100 (%) PWMPWM duty cycle (CFM) (CFM) 100% 2.0 50% 200 3.0 2.5 1.5 0.5 0.4 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 0 (min-1) 6000 5000 800 26.4 V 600 24 V 2.0 1.0 PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 1000 PWM PWM duty cycle 10 4000 200 0 0 1010 2020 3030 4040 5050 3.5 600 0 5000 400 0 6850 min-1 6000 26.4 V (inch H2O) (Pa) 24 VDC DC24 V 800 0 464 1200 Operating voltage range 1000 0 8000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 With pulse sensor with PWM control function (inch H2O) (Pa) 400 (min-1) 400 400 (CFM) (CFM) PWM duty cycle 0.5 100 (%) PWM PWM duty cycle PWM duty - Speed characteristics example 600 600 11 200 200 Airflow 1.0 0 (m3/min) 60 (CFM) 7000 22 0 0 1010 2020 3030 4040 5050 1.5 Airflow 1.6 50 1400 1000 4 4 1000 400 400 2.5 1600 0 PWM duty cycle PWM PWM 100% 100% 800 800 00 40 PWM duty cycle 100% PWM100% (inch H2O) (Pa) (inch H2O) (Pa) 600 600 3.0 1.2 30 Operating voltage range 22 3.5 2.0 (CFM) 24 VDC DC24 V V DC24 1000 4 4 1000 00 2000 With pulse sensor with PWM control function (inch H2O) (Pa) (inch H2O) (Pa) 11 3.0 0 PWM duty cycle 33 0.8 20 4.0 1000 2.0 (m3/min) 10 20 30 40 50 60 70 9BMB24P2G01 5.0 1.0 20% 200 0 0.4 10 (inch H2O) (Pa) 24 VDC DC24 V 1600 0 0 3000 1000 100 Operating voltage range Static pressure Static pressure 1.0 10.2 V 200 0 4.0 1000 2.0 12 V 300 With pulse sensor with PWM control function (inch H2O) (Pa) 3.0 4000 13.8 V 400 60 (CFM) PWM duty cycle 5.0 0.5 20% 0 6.0 1 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 4500 min-1 500 Fan speed 200 1.5 5000 Fan speed 300 1 2 (min-1) PWM duty cycle 100% PWM100% 600 Fan speed 1.5 500 Static pressure Static pressure 2 2.5 12 VDC DC12 V 600 Static pressure 2.5 PWM duty - Speed characteristics example Fan speed PWM duty cycle 400 21.6 V 200 0 0 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 5250 min-1 4000 3000 2000 1000 0.8 0.4 10 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 0 100 (%) PWM PWM duty cycle Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9BMB24P2H01 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 3.5 3.5 3.0 600 2.5 3.0 600 2.5 PWM duty cycle PWM 100% 2.0 400 1.5 50% 1.0 200 0.4 10 9BMB24P2F01 0.8 20 30 Airflow 40 50 0 0 0.4 10 0.8 20 30 40 Airflow 1.5 1.0 50 0 0 9BMB12G201 Static pressure Static pressure 12 V 800 7V 600 400 200 0 0 1.0 1.5 Airflow 9BMB12S201 With pulse sensor 1.0 12 V 300 200 7V 100 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 1.0 800 13.8 V 600 12 V 400 3.5 7V 200 3.0 2.5 0 0.4 10 0.8 20 30 1.2 40 1.5 1.0 Airflow 0 1.6 (m3/min) 50 0 7V 200 0 0.4 10 0.8 20 1.2 30 40 Airflow 1.6 (m3/min) 50 (CFM) With pulse sensor Operating voltage range (inch H2O) (Pa) 13.8 V 400 12 V 300 7V 5.0 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) 1600 1400 1200 26.4 V 4.0 1000 3.0 2.0 1.0 100 0 12 V 400 9BMB24K201 With pulse sensor 13.8 V 600 0 (CFM) 6.0 0 800 2.0 0.5 200 0.5 With pulse sensor Operating voltage range 2.0 500 1.5 100 (%) 0 PWM PWM duty cycle (CFM) 1000 0 Static pressure Static pressure 400 0 Airflow 50 2.5 600 13.8 V 0 40 (inch H2O) (Pa) 2.0 500 0 1.6 (m3/min) 1.2 30 Operating voltage range 2.5 600 0.5 1.5 2000 (inch H2O) (Pa) 9BMB12F201 With pulse sensor (inch H2O) (Pa) 1.0 0.8 20 2.0 (CFM) Operating voltage range 1.5 2.5 0 2.0 (m3/min) 0 10 20 30 40 50 60 70 9BMB12H201 3.0 0.5 0.5 0.4 10 Operating voltage range 13.2 V 3000 1000 1000 4.0 1000 24 V 21.6 V 0 3.5 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 200 (inch H2O) (Pa) 5.0 1200 5000 26.4 V 400 1600 1400 (min-1) 4500 min-1 (CFM) With pulse sensor PWM duty - Speed characteristics example PWM duty cycle 100% PWM100% 600 (inch H2O) (Pa) 1.0 100 (%) 0 PWM PWM duty cycle (CFM) 0.5 1.6 (m3/min) 1.2 Operating voltage range 2.0 50 Static pressure 9BMB12K201 40 DC 50% 0 2000 Blower 97 mm 100% Static pressure PWM PWM duty cycle 400 0 1.6 (m3/min) 1.2 30 Airflow 2.0 0.5 3.0 0.8 20 Fan speed 2.5 1.0 6.0 0.4 10 (inch H2O) (Pa) 24 VDC DC24 V 600 200 3000 1000 Operating voltage range 2.0 Static pressure 1.0 200 0 4850 min-1 With pulse sensor with PWM control function (inch H2O) (Pa) 0 21.6 V 1.5 (CFM) PWM duty cycle 1.5 24 V 2.0 400 1.6 (m3/min) 1.2 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 4000 26.4 V Static pressure 0 0 2.5 5000 0.5 0.5 0 (min-1) PWM duty cycle 100% PWM100% 800 Static pressure Static pressure (inch H2O) (Pa) 24 VDC DC24 V 800 PWM duty - Speed characteristics example Fan speed PWM duty cycle 0 24 V 800 21.6 V 600 400 200 0 0 0.5 1.0 1.5 2.0 (m3/min) 10 20 30 40 50 60 70 Airflow (CFM) 465 Airflow - Static Pressure Characteristics 9BMB24G201 9BMB24S201 With pulse sensor Operating voltage range 9BMB24H201 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 1000 1000 2.5 600 2.0 500 2.5 600 24 V 2.0 400 1.5 1.0 12 V 200 0.5 0 3.0 2.5 0.4 10 0 9BMB24F201 0.8 20 1.2 30 40 Airflow 600 1.5 24 V 1.0 400 12 V 200 0 1.6 (m3/min) 50 26.4 V 2.0 0.5 0 800 Static pressure 26.4 V 800 3.0 3.5 Static pressure Static pressure 3.5 0 0.4 0 (CFM) 10 0.8 20 30 With pulse sensor 1.2 40 Airflow 1.0 26.4 V 400 24 V 300 200 0.5 0 1.6 (m3/min) 50 1.5 12 V 100 0 0.4 0 (CFM) 10 0.8 20 30 With pulse sensor (inch H2O) (Pa) 600 Static pressure 2.0 500 1.5 1.0 26.4 V 400 24 V 300 200 0.5 0 12 V 100 0 0 0.4 10 0.8 20 30 1.2 40 1.6 (m3/min) 50 Airflow (CFM) 30 6) 8. (1 .2 R51 466 1 Rotating direction (10 ) (5) (21) (50) (10) 97.11 390.3 31.50.3 AIRFLOW 4-o4.50.3 hole Mounting 390.3 450.3 951 (1.5) 0 (8) 30 (58) Lead wire AWG24 UL 1430 (52) 1 .6 (1.5) 390.3 320.3 R59 6) 8. (1 331 (1.5) Dimensions (unit: mm) (With pulse sensor with PWM control function) (2.4) o56 1 260.3 320.3 Airflow direction 40 Airflow Operating voltage range 2.5 1.2 1.6 (m3/min) 50 (CFM) Blower 97x33 mm San Ace B97 9BM type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Yellow Sensor Mass ...................................................... 175 g Specifications Operating voltage range Rated current Rated input [V] 109BM12GC2-1 109BM12HC2-1 109BM12MC2-1 109BM24GC2-1 109BM24HC2-1 109BM24MC2-1 [V] 12 7 to 13.8 24 12 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.6 0.4 0.26 0.31 0.26 0.15 7.2 4.8 3.12 7.44 6.24 3.6 3800 3300 2700 3800 3300 2700 0.82 0.71 0.58 0.82 0.71 0.58 28.9 25.1 20.5 28.9 25.1 20.5 281 204 119 281 204 119 [inchHO] 1.129 0.819 0.478 1.129 0.819 0.478 SPL Operating temperature Expected life [dB (A)] [C] [h] 51.5 48.5 43.5 51.5 48.5 43.5 -20 to +70 40000/60C (70000/40C) Blower 97 mm Rated voltage Model no. The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 561. PWM control Airflow - Static Pressure Characteristics 109BM12GC2-1 109BM12HC2-1 With pulse sensor Operating voltage range 109BM12MC2-1 With pulse sensor Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) 400 1.2 300 0.8 200 200 7V 150 100 50 0 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 10 20 30 Airflow 40 (CFM) 13.8 V 0.8 200 12 V 0.6 150 7V 0.4 100 0.2 50 0 0 0 Static pressure 12 V 1.0 250 0.5 1.0 250 13.8 V 300 Static pressure Static pressure 350 0.2 0.4 10 0.6 20 With pulse sensor Operating voltage range (inch H2O) (Pa) 1.5 DC The models listed below have pulse sensors. Airflow 0.8 30 1.0 (m3/min) (CFM) 0.6 150 13.8 V 0.4 100 0.2 50 0 0 0 12 V 7V 0.2 0.4 10 0.6 20 Airflow 0.8 30 1.0 (m3/min) (CFM) 467 Airflow - Static Pressure Characteristics 109BM24GC2-1 109BM24HC2-1 With pulse sensor Operating voltage range 109BM24MC2-1 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 400 1.2 300 0.8 200 24 V 1.0 250 200 0.5 1.0 250 27.6 V 300 12 V 150 100 50 0 0 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 10 20 30 Airflow 40 27.6 V 0.8 200 24 V 0.6 150 12 V 0.4 100 0.2 50 0 0 0 (CFM) Static pressure 350 Static pressure Static pressure 1.5 0.2 0.4 10 0.6 20 With pulse sensor 0.8 Airflow 1.0 (m3/min) 30 0.6 150 27.6 V 0.4 100 0.2 50 0 0 0 (CFM) 24 V 12 V 0.2 0.4 10 Airflow (3) (20) 97.21 501 390.3 (10) 2-o4.50.3 Mounting hole 0 30 30 (10 ) Lead wire AWG24 UL 1007 Rotating direction 468 390.3 94.51 AIRFLOW 320.3 (8) 581 521 (3) 331 (1.2) Dimensions (unit: mm) (3.9) o55 1 320.3 Airflow direction 0.6 20 0.8 30 1.0 (m3/min) (CFM) Blower 120x32 mm San Ace B120 9BFB type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black Sensor Yellow Brown Control Mass ...................................................... 340 g Specifications The models listed below have pulse sensors with PWM control function. [V] [V] 9BFB12P2H003** 12 10.8 to 13.2 9BFB24P2H003 24 21.6 to 26.4 Rated current Rated input Rated speed 100 100 0 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 2.3 1.1 0.12 27.6 26.4 2.88 3750 3750 1300 1.6 1.6 0.46 56.5 56.5 16.2 1250 1250 43 [inchHO] 5.02 5.02 0.17 SPL Operating temperature Expected life [dB (A)] [C] [h] 62 62 41 -20 to +70 40000/60C (70000/40C) ** Fan does not rotate when PWM duty cycle is 0%. DC * PWM frequency: 25 kHz PWM duty cycle* [%] Airflow - Static Pressure Characteristics / PWM Duty - Speed Characteristics Example 9BFB12P2H003 With pulse sensor with PWM control function Operating voltage range (inch H2O) (Pa) 6.0 1400 5.0 1200 100% 4.0 1000 2.0 1.0 0 800 600 50% 400 0 0 Static pressure DC24 V 24 VDC 1600 PWM duty cycle PWM 100% 2.0 1.0 0 800 600 400 200 0 0 13.2 V 12 V 10.8 V 800 600 1000 1.0 1.5 2.0 (m3/min) When fan operates 350 Pa at 350 Pa static pressure 3750 3750min min-1-1 Free air, when fan operates at zero static pressure 3000 200 0.5 -1 5000 5000min min-1 4000 2000 0 7000 7000min min-1-1 When fan operates 800 Pa at 800 Pa static pressure 5000 400 0 Voltage: 12 VDC DC12 V PWM frequency:kHz 25 kHz PWM25 6000 0 10 20 30 40 50 60 70 100 (%) duty cycle PWMPWM (CFM) Airflow (inch H2O) (Pa) 6.0 4.0 1000 3.0 7000 Operating voltage range (inch H2O) (Pa) 5.0 1200 2.0 (min-1) PWM duty cycle 100% PWM100% With pulse sensor with PWM control function PWM duty cycle 1400 3.0 Airflow 9BFB24P2H003 6.0 4.0 1000 0 1.5 2.0 (m3/min) 1.0 0.5 10 20 30 40 50 60 70 (CFM) 1400 5.0 1200 1.0 200 1600 50% 0% 1.5 2.0 (m3/min) 1.0 0.5 10 20 30 40 50 60 70 (CFM) Airflow 1600 1400 5.0 1200 4.0 1000 3.0 2.0 1.0 0 PWM duty - Speed characteristics example (min-1) PWM duty cycle 100% PWM100% 7000 26.4 V 6000 24 V 21.6 V Fan speed 3.0 Static pressure PWM duty cycle PWM Static pressure Static pressure 6.0 (inch H2O) (Pa) 12 VDC DC12 V 1600 PWM duty - Speed characteristics example Fan speed PWM duty cycle 800 600 400 4000 3000 -1 -1 7000 min 7000 min When operates at fan 850 Pa 850 Pa static pressure -1 5000 min 5000 min-1 When operates at fan 500 Pa 500 Pa static pressure -1 -1 3750 min 3750 min Free air, when fan operates at zero static pressure 2000 1000 200 0 5000 Voltage: 24 VDC DC24 V PWM frequency:kHz 25 kHz PWM25 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) 0 100 (%) PWM duty cycle PWM Airflow 469 Blower 120 mm Rated voltage Operating voltage range Model no. Dimensions (unit: mm) (56) 5 (15) (22) 3-R 920.3 1201 (7.5) (2) 1050.3 (63.8) 920.3 321 (28) (0.8) (2) (2) 0 +3 0 0 30 ) (10 Lead wire AWG24 UL 1430 .5 (5) Airflow direction 0 0.2 7 o7 -o4.3 hole 9 g n ti un Mo 880.3 (15) 900.3 (22.5) Rotating direction 470 (7.5) 1050.3 1201 (71.7) 880.3 650.3 (63.7) AIRFLOW Blower 127x32 mm San Ace B127 9BJ type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Yellow Sensor Mass ...................................................... 290 g Specifications The models listed below have pulse sensors. [V] 109BJ12HC2 109BJ12MC2 109BJ24HC2 109BJ24MC2 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.52 0.29 0.26 0.15 6.24 3.48 6.24 3.6 2400 1900 2400 1900 0.78 0.61 0.78 0.61 27.5 21.5 27.5 21.5 205.8 109.8 205.8 109.8 SPL [inchHO] Operating temperature Expected life [dB (A)] 0.826 0.441 0.826 0.441 [C] 46 40 46 40 [h] -20 to +70 40000/60C -20 to +60 DC Rated voltage Operating voltage range Rated current Rated input Model no. The following sensor and control options are available for selection. Lock sensor Blower 127 mm Available for all models. Without sensor Airflow - Static Pressure Characteristics 109BJ12HC2 109BJ12MC2 With pulse sensor Operating voltage range Operating voltage range (inch H2O) (Pa) Static pressure 1.0 0.8 200 0.6 0.4 13.8 V 0.7 12 V 0.6 10.2 V 100 0.2 0 (inch H2O) (Pa) 1.2 200 150 0.5 0.4 12 V 100 10.2 V 0.3 0.2 50 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 27.6 V 0.8 24 V 200 0.6 0.4 20.4 V 100 0.2 0.1 0 300 1.0 13.8 V Static pressure 0.8 With pulse sensor Operating voltage range (inch H2O) (Pa) 300 Static pressure 1.2 109BJ24HC2 With pulse sensor 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 471 Airflow - Static Pressure Characteristics 109BJ24MC2 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.8 200 Static pressure 0.7 0.6 27.6 V 150 0.5 0.4 24 V 100 20.4 V 0.3 0.2 50 0.1 0 0 0.5 0 10 1.0 20 30 Airflow 40 1.5 (m3/min) 50 (CFM) Dimensions (unit: mm) 111.90.5 Rotating direction 472 50.5 6-o4.30.3 Mounting hole (54.4) 104.80.5 Airflow direction 1271 o70 (62.4) AIRFLOW 104.80.5 1.5 (12) (62) 10 (16.5) (2) (70) (3.5) (48.5) (50.4) 1261 +1 32 0 75.51 (2.5) 1241 (52.6) 1201 85.60.5 +30 300 0 (10) Lead wire AWG24 UL 1007 Blower 160x40 mm San Ace B160 9BG type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Red Black or Blue Sensor Yellow Mass ...................................................... 580 g Specifications The models listed below have pulse sensors. [V] 109BG12HC1 109BG12MC1 109BG24HC1 109BG24MC1 [V] 12 10.2 to 13.8 24 20.4 to 27.6 Rated speed Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 1.3 0.64 0.62 0.31 15.6 7.68 14.88 7.44 2300 1800 2300 1800 1.62 1.26 1.62 1.26 57.2 44.5 57.2 44.5 313.6 156.8 313.6 156.8 SPL [inchHO] 1.259 0.629 1.259 0.629 Operating temperature Expected life [dB (A)] [C] [h] 55 50 55 50 -20 to +60 40000/60C DC Rated voltage Operating voltage range Rated current Rated input Model no. The following sensor and control options are available for selection. Lock sensor Blower 160 mm Available for all models. Without sensor Airflow - Static Pressure Characteristics 109BG12HC1 109BG12MC1 With pulse sensor Operating voltage range Operating voltage range 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (inch H2O) (Pa) 1.0 13.8 V 12 V 10.2 V 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) 200 0.6 150 0.4 100 0.2 50 0 (inch H2O) (Pa) 250 0.8 0 With pulse sensor Operating voltage range Static pressure 450 Static pressure Static pressure (inch H2O) (Pa) 1.8 109BG24HC1 With pulse sensor 13.8 V 12 V 10.2 V 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) 1.8 450 1.6 400 1.4 350 1.2 300 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 24 V 20.4 V 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) 473 Airflow - Static Pressure Characteristics 109BG24MC1 With pulse sensor Operating voltage range Static pressure (inch H2O) (Pa) 1.0 250 0.8 200 0.6 150 0.4 100 0.2 50 0 0 27.6 V 24 V 20.4 V 0.4 0.8 1.2 1.6 2.0 (m3/min) 0 10 20 30 40 50 60 70 Airflow (CFM) Rotating direction 16 (80.2) 60.5 3-o4.8 Mounting hole 3-o4.3 Mounting hole o9 6 (73.3) 135.20.5 Airflow direction (160) AIRFLOW (80.2) 2 (2) 73.11 (2) 120.5 24.10.5 144.20.5 474 401 (6) (66.5) (46.6) (86.3) (3.2) (160) 138.20.5 Lead wire AWG24 UL 1007 127.90.5 (80.2) +30 300 0 (10) Dimensions (unit: mm) ACDC Fan This fan works while internally converting AC power into DC power, providing the superior performance of a DC fan with the flexibility of AC input. Low power consumption Long life Wide voltage range (Compared with our existing AC fan with equal size.) With AC input, the same level of energy saving and long life as a DC fan can be achieved. The maintenance effort can be reduced too. Power consumption comparison AC fan 109S072UL Expected life comparison 16 W AC fan 109S072UL 25000 h 4.4 W 0 ACDC fan 9AD1201H12 5 10 25000 h 2.4 times longer 72% reduction ACDC fan 9AD1201H12 Replacement 15 Expected life 60000 h at 60C 20 (W) Model Numbering System Not every combination of the following codes or characters is available. Contact us for an available combination. 09 01 H 1 2 Type name Frame size Voltage Speed code Frame thickness Sensor specifications 9AD Frame size (mm) 09 12 92 x 92 120 x 120 Voltage (V) 01 100 to 240 Speed code H M etc. Frame thickness (mm) Sensor specifications Frame form ACDC Fan Type name Frame form AC 9AD 1 38 2 H Without a sensor With a low-speed sensor Nil 1 Plastic frame: Ribbed frame Plastic frame: Ribless frame How to Read Specifications (ACDC fan) Model no. Rated voltage [V] Operating voltage range [V] Frequency [Hz] 9AD0901H12 9AD0901M12 100 to 240 90 to 264 50/60 Rated voltage ..................... Operating voltage range ......... Frequency ........................... Rated current ..................... Rated input ........................ Rated speed ........................ Max. airflow ........................ Max. static pressure ............ SPL .................................... Operating temperature ......... Expected life ........................ Rated current Rated input Rated speed [A] [W] [min-1] 0.08 0.06 4.5 3.0 3850 3100 Max. airflow [m/min] [CFM] 1.5 1.18 53.0 41.7 Max. static pressure [Pa] [inchHO] 90 56 0.36 0.22 SPL [dB (A)] Operating temperature [C] Expected life [h] 40 33 -20 to +75 60000/60C This is the necessary voltage to drive the fan. Single-phase 100 to 240 VAC are also available. The voltage range over which fan operation is guaranteed. This is a frequency of alternating current (AC). The frequencies of 50 Hz and 60 Hz are existing in Japan. The current when the fan is operating at rated voltage (at free air). The power value when the fan is operating at rated voltage (at free air). The speed when the fan is operating at rated voltage (at free air). The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. The temperature range over which fan operation is guaranteed (Non- condensing). Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. For more information, please refer to the technical material section. 475 ACDC Fan 92x92x38 mm San Ace 92AD 9AD type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Brushless DC motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame, and between sensor output and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +75C (Non-condensing) Mass ...................................................... 250 g Do not solder wires directly to AC input terminals. Specifications The models listed below have ribs and no sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage [V] Operating voltage range [V] Frequency [Hz] 9AD0901H12 9AD0901M12 100 to 240 90 to 264 50/60 Rated current Rated input Rated speed [A] [W] [min-1] 0.08 0.06 4.5 3.0 Max. airflow [m/min] [CFM] 3850 3100 1.5 1.18 53.0 41.7 Max. static pressure [Pa] [inchHO] 90 56 0.36 0.22 SPL [dB (A)] Operating temperature [C] Expected life [h] 40 33 -20 to +75 60000/60C The models listed below have ribs and low-speed sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage [V] Operating voltage range [V] Frequency [Hz] 9AD0901H1H 9AD0901M1H 100 to 240 90 to 264 50/60 Rated current Rated input Rated speed [A] [W] [min-1] 0.08 0.06 4.5 3.0 Max. airflow [m/min] [CFM] 3850 3100 1.5 1.18 53.0 41.7 Max. static pressure [Pa] [inchHO] 90 56 0.36 0.22 SPL [dB (A)] Operating temperature [C] Expected life [h] 40 33 -20 to +75 60000/60C Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 9AD0901H12 9AD0901M12 9AD0901H1H 9AD0901M1H ST1-9AD0901H12 ST1-9AD0901M12 ST1-9AD0901H1H ST1-9AD0901M1H Voltage Low-speed sensor 100 to 240 V Plug cord 489-1635-L10 489-1635-L10 489-1635-L10 489-1635-L10 Airflow - Static Pressure Characteristics 9AD0901H12, 9AD0901H1H 9AD0901M12, 9AD0901M1H (inch H2O) (Pa) (inch H2O) (Pa) 100 60 0.3 100 to 240VV50/60 50/60Hz Hz 100240 60 0.2 40 0.1 0 20 0 0 476 0.20 80 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) Static pressure Static pressure 0.4 0.15 0.10 0.05 0 50 100 to 240VV50/60 50/60 Hz Hz 100240 40 30 20 10 0 0 0.4 10 0.8 20 30 1.2 40 Airflow 1.6 (m3/min) 50 (CFM) Finger guards 109-099E 109-099E 109-099E 109-099E Mounting screws M4x55 mm (4 screws) Dimensions (unit: mm) (With ribs) with Low-speed sensor 4-o4.30.3 Mounting hole 10010 without Sensor 920.5 (4) 82.50.3 82.50.3 920.5 82.50.3 4-o4.30.3 Mounting hole 82.50.3 (4) 380.5 920.5 Rotating direction Airflow direction Lead wire AWG24 AWG24 UL UL 1007 1007 (4) 920.5 Rotating direction (4) 380.5 Airflow direction Tyco Electronics171822-2 171822-2 Connector: Tyco Electronics (Pin1 Pin.1Sensor output: YellowPin.2 Pin2 --: Black) Electronics 170262-1 Contact: Tyco Tyco Electronics 170262-1 * Recommended connectors and contacts are listed below. TycoElectronics Electronics172211-2 172211-2 Tyco Connector: Tyco Electronics 170376-1 Contact: Tyco Electronics 170376-1 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Outlet side 90.5 AC Inlet side 90.5 4-o4.5 ACDC Fan 92 mm sq. 4-o4.5 05 7 o1 82.50.3 90.5 90.5 82.50.3 o9 82.50.3 82.50.3 without Sensor with Low-speed sensor AC power supply AC power supply Wiring Diagram FAN FAN Photocoupler Yellow 10 mA max. Pull-up resistor +27.6 V max. Senser output Black GND (0 V) 477 Specifications for Low-speed Sensors Typical standard model: 9AD0901H1H Output circuit: Open collector Sensor scheme VCE=+27.6 VDC max. Ic=10 mA max. [VCE (SAT)=1.0 V max.] Inside of DC fan Example 1: when steady running Fan power Pull-up voltage +27.6 VDC max. Trip point Fan speed Pull-up resistor Photocoupler Sensor Ic=10 mA max. Sensor output (VCE) Startup delay Sensor output Detection delay H H L VCE (SAT)=1.0 V max. Example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. Fan power Trip point Fan speed Startup delay Sensor output Detection delay H H L 9AD0901H1H 9AD0901M1H Startup delay: 183 s Startup delay: 363 s Detection delay: 3 s max. Detection delay: 3 s max. Trip point: 1700 min-1 Trip point: 850 min-1 Options Finger guards page: p. 532 Model no.: 109-099C, 109-099E, 109-099H Resin filter kits Model no.: 489-1636 478 page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) Wiring harness for sensor Resin finger guards page: p. 543 Plug cord Model no.: 489-1635-L10, 489-1635-L21 page: p. 543 ACDC Fan 120x120x38 mm San Ace 120AD 9AD type General Specifications Material ................................................ Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Brushless DC motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame, and between sensor output and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Storage temperature ........................... -30 to +75C (Non-condensing) Mass ...................................................... 290 g Do not solder wires directly to AC input terminals. Specifications The models listed below have ribs and no sensors. For models without ribs, append "1" to the end of model numbers. Model no. 9AD1201H12 Rated voltage [V] Operating voltage range [V] Frequency [Hz] 100 to 240 90 to 264 50/60 Rated current Rated input Rated speed [A] [W] [min-1] 0.08 4.4 3250 Max. airflow [m/min] [CFM] 3.0 106 Max. static pressure [Pa] [inchHO] 84 0.34 SPL [dB (A)] Operating temperature [C] Expected life [h] 42 -20 to +75 60000/60C Model no. Rated voltage [V] Operating voltage range [V] Frequency [Hz] 9AD1201H1H 100 to 240 90 to 264 50/60 Rated current Rated input Rated speed [A] [W] [min-1] 0.08 4.4 3250 Max. airflow [m/min] [CFM] 3.0 106 Max. static pressure [Pa] [inchHO] 84 0.34 SPL [dB (A)] Operating temperature [C] Expected life [h] 42 -20 to +75 60000/60C ACDC Fan 120 mm sq. Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 9AD1201H12 9AD1201H1H ST1-9AD1201H12 ST1-9AD1201H1H Voltage 100 to 240 V Low-speed sensor Plug cord 489-1635-L10 489-1635-L10 Finger guards 109-019E 109-019E Mounting screws M4x55 mm (4 screws) Airflow - Static Pressure Characteristics 9AD1201H12, 9AD1201H1H (inch H2O) (Pa) 0.4 Static pressure 90 0.3 80 100 to 240 240 VV50/60 50/60Hz Hz 70 60 0.2 50 40 0.1 30 20 10 0 0 1 0 2 50 3 100 Airflow 4 (m3/min) 150 (CFM) AC The models listed below have ribs and low-speed sensors. For models without ribs, append "1" to the end of model numbers. 479 Dimensions (unit: mm) (With ribs) without Sensor 1200.8 (6) 104.80.3 1200.8 Lead wire AWG24 AWG24 UL UL1007 1007 104.80.3 4-o4.30.3 Mounting hole 104.80.3 1200.8 4-o4.30.3 Mounting hole 10010 with Low-speed sensor (6) 104.80.3 1200.8 380.5 Rotating direction (6) Rotating direction Airflow direction Tyco TycoElectronics Electronics171822-2 171822-2 Connector: (Pin1 Pin.1Sensor output: YellowPin.2 Pin2--: Black) Electronics 170262-1 Contact: Tyco Tyco Electronics 170262-1 * Recommended connectors and contacts are listed below. Connector: 172211-2 TycoElectronics Electronics 172211-2 Tyco Contact: Tyco Electronics 170376-1 Tyco Electronics 170376-1 Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 104.80.3 4-o4.5 35 27 o1 118 104.80.3 118 o1 4-o4.5 118 104.80.3 104.80.3 118 without Sensor with Low-speed sensor AC power supply AC power supply Wiring Diagram 480 FAN FAN Photocoupler 10 mA max. Yellow Pull-up resistor +4 to 27.6 VDC Senser output Black GND (0 V) (6) 380.5 Airflow direction Specifications for Low-speed Sensors Model No.: 9AD1201H1H Output circuit: Open collector Sensor scheme VCE=+27.6 VDC max. Ic=10 mA max. [VCE (SAT)=1.0 V max.] Inside of DC fan Example 1: when steady running Fan power Pull-up voltage +4 to 27.6 VDC Trip point Fan speed Pull-up resistor Photocoupler Sensor Ic=10 mA max. Sensor output (VCE) Startup delay Sensor output Detection delay H H L VCE (SAT) Example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. Fan power Trip point Fan speed Startup delay Sensor output Detection delay H H L Startup delay: 183 s Trip point: 1700 min-1 Options Finger guards page: p. 533 Resin finger guards Model no.: 109-019C, 109-019H, 109-019E, 109-019K Model no.: 109-1000G Resin filter kits Plug cord page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) Wiring harness for sensor page: p. 539 page: p. 543 Model no.: 489-1635-L10, 489-1635-L21 page: p. 543 Model no.: 489-1636 481 ACDC Fan 120 mm sq. AC Detection delay: 3 s max. 482 AC Fan The cooling fan operates at 100 to 230 VAC. How to Read Specifications (AC fan) Model no. 109-180 109-183 Rated voltage [V] 100 115 Frequency [Hz] 50/60 Input [W] 5/4 Current [A] Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.07/0.06 0.06/0.05 2250/2700 0.27/0.33 9.5/11.7 0.06/0.05 Max. static pressure [Pa] [inchHO] SPL [dB (A)] 11.8/18.6 0.047/0.075 24/26 Operating temperature Expected life -30 to +70 25000/60C [C] [h] AC Fan AC Rated voltage ..................... This is the necessary voltage to drive the fan. Single-phase 100, 115, 200 and 230 VAC are also available. Frequency ........................... This is a frequency of alternating current (AC). The frequencies of 50 Hz and 60 Hz are existing in Japan. Performance of AC fan varies depending on the frequency. Example: Rated speed 2250/2700 = 50 Hz 2250, 60 Hz 2700 Input ................................. The power value when the fan is operating at rated voltage (at free air). Current .............................. The current when the fan is operating at rated voltage (at free air). Locked rotor current ............ This is a current when rotor of motor that applies rated voltage is locked. Rated speed ........................ The speed when the fan is operating at rated voltage (at free air). Max. airflow ........................ The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time. Max. static pressure ............ The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed. SPL .................................... SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method. Operating temperature ......... The temperature range over which fan operation is guaranteed (Non- condensing). Expected life ........................ Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60C temperature. For more information, please refer to the technical material section. 483 AC Fan 60x60x28 mm San Ace 60 General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Black, 2 pcs Mass ...................................................... 120 g Specifications Rated voltage Model no. [V] 100 115 109-180 109-183 Frequency Input [Hz] [W] 50/60 5/4 Current [A] Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.07/0.06 0.06/0.05 2250/2700 0.27/0.33 9.5/11.7 0.06/0.05 Max. static pressure [Pa] [inchHO] SPL [dB (A)] 11.8/18.6 0.047/0.075 24/26 Operating temperature Expected life -30 to +70 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan Voltage ST1-109-180 109-180 100 V ST1-109-183 109-183 115 V Airflow - Static Pressure Characteristics 109-180, 109-183 (inch H2O) (Pa) 0.12 30 Static pressure 0.10 0.08 60 Hz 100 V/115 V 20 50 Hz 100 V/115 V 0.06 0.04 10 0.02 0 0 0.2 0 484 5 0.4 10 Airflow 15 (m3/min) (CFM) Low-speed sensor Plug cord Plug cord is not included because of the exposedlead structure. Finger guards Mounting screws 109-139E M4x40 mm (4 screws) 109-139E Dimensions (unit: mm) 8-o4.3 Mounting hole 600.5 500.3 280.5 (3) (3) AIRFLOW 500.3 600.5 +50 300 0 (10) Lead wire AWG26 UL 1430 M4x0.7 Earth ground tap Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 58 500.3 4-o4.5 500.3 500.3 o6 58 3 9 o5 500.3 4-o4.5 AC Fan 60 mm sq. AC AC power supply AC Wiring Diagram FAN Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 485 AC Fan 60x60x38 mm San Ace 60 General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Black, 2 pcs Mass ...................................................... 170 g Specifications Model no. Rated voltage [V] 100 115 109-130 109-133 Frequency Input [Hz] [W] 50/60 6/5 Current [A] Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] Max. static pressure [Pa] [inchHO] SPL [dB (A)] 0.08/0.07 0.08/0.07 2600/3150 0.33/0.4 11.7/14.1 16.3/23.3 0.065/0.094 28/30 0.07/0.06 0.07/0.06 Operating temperature Expected life -30 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan Voltage ST1-109-130 109-130 100 V ST1-109-133 109-133 115 V Airflow - Static Pressure Characteristics 109-130, 109-133 (inch H2O) 0.12 (Pa) 30 Static pressure 0.10 0.08 60 Hz 100 V/115 V 20 50 Hz 100 V/115 V 0.06 0.04 10 0.02 0 0 0.2 0 486 5 0.4 10 Airflow 15 (m3/min) (CFM) Low-speed sensor Plug cord Plug cord is not included because of the exposedlead structure. Finger guards Mounting screws 109-139E M4x55 mm (4 screws) 109-139E Dimensions (unit: mm) 8-o4.3 Mounting hole 600.5 500.3 380.5 (3) (3) 500.3 600.5 +50 300 0 AIRFLOW (10) Lead wire AWG26 UL 1430 M4x0.7 Earth ground tap Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 58 500.3 4-o4.5 500.3 AC 500.3 o6 58 3 9 o5 500.3 4-o4.5 AC power supply AC AC Fan 60 mm sq. Wiring Diagram FAN Options Finger guards page: p. 532 Model no.: 109-139E, 109-139H Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1003G page: p. 540 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) 487 AC Fan 80x80x20 mm San Ace 80 General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Lead wire ............................................. Black, 2 pcs Mass ...................................................... 180 g Specifications Rated voltage Model no. [V] 100 115 109-210 109-213 Frequency Input [Hz] [W] 50/60 6/5 Current [A] Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] Max. static pressure [Pa] [inchHO] SPL [dB (A)] 0.07/0.06 0.07/0.06 2500/3000 0.44/0.53 15.5/18.7 23.5/31.4 0.094/0.126 26/31 0.06/0.05 0.06/0.05 Operating temperature Expected life -30 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan Voltage ST1-109-210 109-210 100 V ST1-109-213 109-213 115 V Airflow - Static Pressure Characteristics 109-210, 109-213 (inch H2O) (Pa) Static pressure 0.15 40 60 Hz 100 V/115 V 30 50 Hz 100 V/115 V 0.10 20 0.05 0 10 0 0.2 0 488 5 0.4 10 15 Airflow 0.6 (m3/min) 20 (CFM) Low-speed sensor Plug cord Plug cord is not included because of the exposedlead structure. Finger guards Mounting screws 109-049E M4x40 mm (4 screws) 109-049E Dimensions (unit: mm) 800.5 71.50.3 200.5 (3.5) 8-o4.3 (3.5) Mounting hole 800.5 71.50.3 M4 0.76 M4 xx 0.7, 6 mm deep Earth ground tap 300L AIRFLOW Lead wire AWG22 UL 1430 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Outlet side 4-o4.5 8 71.50.3 o7 71.50.3 4-o4.5 5 9. o8 78 71.50.3 71.50.3 Inlet side 78 AC Fan 80 mm sq. AC power supply AC AC Wiring Diagram FAN Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 489 AC Fan 80x80x25 mm San Ace 80 General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Mass ...................................................... 270 g Specifications Rated voltage Model no. [V] Frequency [Hz] 100 115 200 230 100 115 200 230 109S050 109S053 109S051 109S054 109S030 109S033 109S031 109S034 Input Current 9/7 0.12/0.1 0.1 /0.08 0.06/0.05 0.05/0.04 0.12/0.1 0.1 /0.08 0.06/0.05 0.05/0.04 [W] 50/60 Locked rotor current Rated speed [A] Max. airflow [min-1] [A] 0.13/0.11 0.11/0.09 0.06/0.05 0.05/0.04 0.13/0.11 0.11/0.09 0.06/0.05 0.05/0.04 [m/min] 2650/3100 Max. static pressure [CFM] 0.63/0.76 22.3/26.9 2350/2700 0.55/0.63 19.4/22.3 SPL [Pa] [inchHO] [dB (A)] 27.5/38.3 0.11 /0.154 30/33 21.6/28.4 0.087/0.114 Operating temperature Expected life -30 to +60 25000/60C [C] [h] 28/30 Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 109S050 109S053 109S051 109S054 109S030 109S033 109S031 109S034 ST1-109S050 ST1-109S053 ST1-109S051 ST1-109S054 ST1-109S030 ST1-109S033 ST1-109S031 ST1-109S034 Voltage Low-speed sensor 100 V 115 V 200 V 230 V 100 V 115 V 200 V 230 V Plug cord* 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 * PSE compatible. ** Though these are 2-hole or 3-hole frame mount types, 4 screws are included for extra. Airflow - Static Pressure Characteristics 109S050, 109S053, 109S051, 109S054 0.15 50 0.20 40 60 Hz 100 V/115 V/200 V/230 V 30 50 Hz 100 V/115 V/200 V/230 V 0.10 20 0.05 0 10 0 0.2 0 490 5 0.4 10 15 0.6 20 Airflow 0.8 25 (m3/min) 30 (CFM) Static pressure Static pressure 0.20 109S030, 109S033, 109S031, 109S034 (inch H2O) (Pa) (inch H2O) (Pa) 0.15 50 40 60 Hz 100 V/115 V/200 V/230 V 30 50 Hz 100 V/115 V/200 V/230 V 0.10 20 0.05 0 10 0 0.25 0 10 0.50 Airflow 20 0.75 Finger guards 109-049E 109-049E 109-049E 109-049E 109-049E 109-049E 109-049E 109-049E (m3/min) 30 (CFM) Mounting screws M4x40 mm (4 screws)** Dimensions (unit: mm) 26 max. 26 800.5 6-o4.3 Mounting hole (3.5) 71.50.3 250.5 (3.5) 71.50.3 800.5 M4 x0.7, 6 mm deep M4 x0.76 Earth ground tap AIRFLOW Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 71.50.3 3-o4.5 78 71.50.3 3-o4.5 5 9. o8 71.50.3 8 o7 71.50.3 AC 78 AC power supply AC AC Fan 80 mm sq. Wiring Diagram FAN Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) Plug cord page: pp. 542 to 543 Model no.: 489-016-L10, 489-016-L21, 489-047-L10, 489-047-L21 491 AC Fan 80x80x38 mm San Ace 80 General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Mass ...................................................... 400 g Specifications Rated voltage Model no. [V] 100 115 200 230 109-150 109-153 109-151 109-154 Frequency [Hz] Input Current 9/8 0.13/0.11 0.11/0.1 0.07/0.06 0.06/0.05 [W] 50/60 [A] Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] Max. static pressure [Pa] [inchHO] SPL [dB (A)] 0.17/0.15 0.14/0.12 2700/3150 0.9/1.05 31.8/37.1 31.4/44.1 0.126/0.177 35/39 0.09/0.08 0.08/0.07 Operating temperature Expected life -30 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 109-150 109-153 109-151 109-154 ST1-109-150 ST1-109-153 ST1-109-151 ST1-109-154 Voltage 100 V 115 V 200 V 230 V Low-speed sensor Plug cord* 489-016-L10 489-016-L10 489-016-L10 489-016-L10 * PSE compatible. ** Though these are 2-hole or 3-hole frame mount types, 4 screws are included for extra. Airflow - Static Pressure Characteristics 109-150, 109-153, 109-151, 109-154 (inch H2O) (Pa) Static pressure 0.20 0.15 50 60 Hz 100 V/115 V/200 V/230 V 40 50 Hz 100 V/115 V/200 V/230 V 30 0.10 20 0.05 0 10 0 0.5 0 492 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) Finger guards 109-049E 109-049E 109-049E 109-049E Mounting screws M4x55 mm (4 screws)** Dimensions (unit: mm) 800.5 7-o4.3 (3.5) Mounting hole (3.5) M4M4 x0.7, 6 mm deep x0.76 Earth ground tap 71.50.3 800.5 71.50.3 380.5 AIRFLOW Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 4-o4.5 71.50.3 5 9. o8 71.50.3 78 78 71.50.3 5 9. o8 3-o4.5 71.50.3 AC 78 AC power supply AC AC Fan 80 mm sq. Wiring Diagram FAN Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) Plug cord page: pp. 542 to 543 Model no.: 489-016-L10, 489-016-L21, 489-047-L10, 489-047-L21 493 AC Fan 80x80x42 mm San Ace 80 General Specifications Material ................................................ Frame: Aluminum (Black coating), Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Mass ...................................................... 410 g Specifications Rated voltage Model no. [V] 100 115 200 230 100 115 109-040UL 109-043UL 109-041UL 109-044UL 109-047UL* 109-033UL* Frequency [Hz] 50/60 Input [W] Current Locked rotor current Rated speed [A] 0.13/0.11 0.11/0.1 10/9 0.07/0.06 0.06/0.05 0.05/0.05 4/3.5 0.04/0.04 Max. airflow [min-1] [A] [m/min] [CFM] Max. static pressure [Pa] [inchHO] SPL [dB (A)] 0.16/0.14 0.14/0.12 2650/3100 0.85/1.0 30.0/35.3 24.5/35.3 0.098/0.142 40/44 0.08/0.07 0.07/0.06 0.05/0.05 1500/1500 0.43/0.43 15.2/15.2 8.8/ 8.8 0.035/0.035 24/24 0.04/0.04 Operating temperature Expected life -30 to +60 25000/60C [C] [h] * These are low-speed models. Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. ST1-109-040UL ST1-109-043UL ST1-109-041UL ST1-109-044UL ST1-109-047UL ST1-109-033UL Fan Voltage 109-040UL 109-043UL 109-041UL 109-044UL 109-047UL 109-033UL 100 V 115 V 200 V 230 V 100 V 115 V Low-speed sensor Plug cord* 489-008-L10 489-008-L10 489-008-L10 489-008-L10 489-008-L10 489-008-L10 * PSE compatible. Airflow - Static Pressure Characteristics 109-040UL, 109-043UL, 109-041UL, 109-044UL (inch H2O) (Pa) (inch H2O) (Pa) 40 30 0.06 50 Hz 100 V/115 V/200 V/230 V 0.05 12 0.04 10 0.03 8 0.10 20 0.05 0 10 0 0.2 0.4 0.6 0.8 1.0 1.2 (m3/min) 0 494 10 16 60 Hz 100 V/115 V/200 V/230 V 20 30 Airflow 40 (CFM) Static pressure Static pressure 0.15 109-047UL, 109-033UL 0.02 14 60 Hz 100 V/115 V 50 Hz 100 V/115 V 6 4 0.01 2 0 0 0.1 0.2 0.3 0.4 0.5 0.6 (m3/min) 0 5 10 15 Airflow 20 (CFM) Finger guards 109-049E 109-049E 109-049E 109-049E 109-049E 109-049E Mounting screws M4x55 mm (4 screws) Dimensions (unit: mm) 800.5 71.50.3 (3) (3) 71.50.3 800.5 M4M4 x0.7, 6 mm deep x0.76 Earth ground tap 420.5 8-o4.3 Mounting hole Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Outlet side 4-o4.5 8 71.50.3 o7 71.50.3 4-o4.5 5 9. o8 78 71.50.3 71.50.3 Inlet side AC 78 AC power supply AC AC Fan 80 mm sq. Wiring Diagram FAN Options Finger guards page: p. 532 Model no.: 109-049E, 109-049H, 109-049C Resin filter kits Resin finger guards page: p. 539 Model no.: 109-1002G page: p. 540 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) Plug cord page: p. 542 Model no.: 489-008-L10, 489-008-L21, 489-008-L35 495 AC Fan 92x92x25 mm San Ace 92 Only standard fans (without sensors) have acquired CSA certification. General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Dielectric strength (with sensor) ......... 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame) 50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Sensor-Purpose lead wire ..................... Brown Black Sensor Yellow Mass ...................................................... 290 g/310 g (with Sensor) Specifications Standard Rated voltage Model no. [V] 100 115 200 230 100 100 115 200 230 109S091 109S093 109S092 109S094 109S095 109S096* 109S193* 109S192* 109S194* Frequency [Hz] 50/60 Input [W] Current [A] 0.1 /0.09 8/7 0.09/0.08 11/10 0.07/0.06 10/9 0.06/0.05 8/7 0.1 /0.09 0.09/0.08 7/6 0.08/0.07 0.06/0.05 8/7 0.05/0.04 Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.13/0.12 0.11/0.1 2700/3100 0.95/1.1 33.6/38.9 0.08/0.08 0.07/0.07 0.11/0.1 2400/2800 0.84/0.98 29.7/34.6 0.09/0.08 0.08/0.07 1500/1700 0.55/0.65 19.4/23 0.06/0.05 0.05/0.04 Max. static pressure SPL [Pa] [inchHO] [dB (A)] 39.2/49.0 0.157/0.197 35/38 31.4/40.2 0.126/0.161 32/35 12.5/16.3 0.05 /0.065 24/27 Operating temperature Expected life -30 to +60 25000/60C [C] [h] * These are low-speed models. with Sensor For sensor specifications, please refer to p. 550. Sensor specification differs depending on the fan's speed specification. For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109S491-20 For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109S491-30 Model no. 109S491 109S493 109S492 109S494 109S495 109S496* Rated voltage [V] 100 115 200 230 Frequency [Hz] 50/60 100 Input [W] Current [A] 0.1 /0.09 8/7 0.09/0.08 11/10 0.07/0.06 10/9 0.06/0.05 8/7 0.1 /0.09 7/6 0.09/0.08 Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.13/0.12 0.11/0.1 2700/3100 0.95/1.1 33.6/38.9 0.08/0.08 0.07/0.07 0.11/0.1 2400/2800 0.84/0.98 29.7/34.6 0.09/0.08 1500/1700 0.55/0.65 19.4/23 Max. static pressure SPL [Pa] [inchHO] [dB (A)] 39.2/49.0 0.157/0.197 35/38 31.4/40.2 12.5/16.3 0.126/0.161 0.05 /0.065 Operating temperature Expected life -10 to +60 25000/60C [C] 32/35 24/27 * These are low-speed models. For the San Ace 92AD 9AD type 92x92x38 mm fan, please refer to p. 476. This fan works while internally converting AC power into DC power, providing the superior performance of a DC fan with the flexibility of AC input. 496 [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 109S091 109S093 109S092 109S094 109S095 109S096 109S193 109S192 109S194 109S491-20 109S491-30 109S493-20 109S493-30 109S492-20 109S492-30 109S494-20 109S494-30 109S495-20 109S495-30 109S496-20 109S496-30 ST1-109S091 ST1-109S093 ST1-109S092 ST1-109S094 ST1-109S095 ST1-109S096 ST1-109S193 ST1-109S192 ST1-109S194 ST1-109S491-20 ST1-109S491-30 ST1-109S493-20 ST1-109S493-30 ST1-109S492-20 ST1-109S492-30 ST1-109S494-20 ST1-109S494-30 ST1-109S495-20 ST1-109S495-30 ST1-109S496-20 ST1-109S496-30 Voltage Low-speed sensor 100 V 115 V 200 V 230 V 100 V 100 V 115 V 200 V 230 V Plug cord* 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) 100 V 115 V 200 V 230 V 100 V Finger guards Mounting screws 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E 109-099E M3x40 mm (4 screws)** * PSE compatible. ** Though these are 2-hole or 3-hole frame mount types, 4 screws are included for extra. Airflow - Static Pressure Characteristics Standard 0.15 0.10 0.05 0 0.20 (inch H2O) (Pa) 30 50 60 Hz 100 V 50 60 Hz 100 V/115 V/200 V/230 V 40 50 Hz 100 V/115 V/200 V/230 V 30 20 10 0 0.5 0 10 1.0 20 30 Airflow 40 0.10 40 50 Hz 100 V 30 0.10 20 0.05 10 0 1.5 (m3/min) 50 0.15 Static pressure Static pressure 0.20 (inch H2O) (Pa) 60 Static pressure 0.25 109S096, 109S193, 109S192, 109S194 0 0.5 0 (CFM) 10 20 30 40 Airflow 50 50 Hz 100 V/115 V/200 V/230 V 0.05 10 0 0 1.5 (m3/min) 1.0 60 Hz 100 V/115 V/200 V/230 V 20 0.5 0 (CFM) 10 20 Airflow 1.0 (m3/min) 30 (CFM) with Sensor 109S491, 109S493, 109S492, 109S494 (inch H2O) (Pa) 0.15 0.10 0.05 0 0.20 (inch H2O) (Pa) 30 50 60 Hz 100 V 50 60 Hz 100 V/115 V/200 V/230 V 40 50 Hz 100 V/115 V/200 V/230 V 30 20 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 0.15 0.10 40 Static pressure Static pressure 0.20 109S496 (inch H2O) (Pa) 60 Static pressure 0.25 109S495 50 Hz 100 V 30 0.10 20 0.05 0 10 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 (m3/min) 50 (CFM) 60 Hz 100 V 20 50 Hz 100 V 0.05 0 10 0 0.5 0 10 20 Airflow 1.0 (m3/min) 30 (CFM) 497 AC (inch H2O) (Pa) 109S095 AC Fan 92 mm sq. 109S091, 109S093, 109S092, 109S094 Dimensions (unit: mm) Standard 26 max. 26 920.5 82.50.3 6-o3.7 (3.5) Mounting hole 250.5 (3.5) AIRFLOW 82.50.3 920.5 M4 x0.7, 6 mm deep M4 x0.76 Earth ground tap Airflow direction Rotating direction 1.5 with Sensor 1.5 Sensor-purpose lead wire Length 300L 300L AWG28 AWG28 UL UL 1007 1007 920.5 46 26 max. 26 250.5 4-o3.7 Mounting hole (3.5) (3.5) AIRFLOW 11 6. 6 0. 5 72 920.5 M4 xx 0.7, 6 mm deep M4 0.76 Earth ground tap Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Standard with Sensor Inlet side, Outlet side 498 0 2-o4 o9 0 o9 82.50.3 11 6. 6 0. 3 82.50.3 Inlet side, Outlet side 3-o4 Wiring Diagram Standard For fan power supply AC power supply AC FAN For sensor circuit 5 V (ITEM-20) 12 V (ITEM-30) Brown Brown +4.5 to 5.5 V 100 mA max. Yellow +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) Sensor circuit with Sensor Sensor circuit AC power supply AC FAN +9.6 to 14.4 V Yellow 200 mA max. +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated. Options page: p. 532 Resin filter kits page: p. 539 Model no.: 109-1001G page: p. 540 Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) Plug cord page: pp. 542 to 543 Model no.: 489-016-L10, 489-016-L21, 489-047-L10, 489-047-L21 AC Model no.: 109-099E, 109-099H, 109-099C Resin finger guards AC Fan 92 mm sq. Finger guards 499 AC Fan 120x120x25 mm San Ace 120 Only standard fans (without sensors) have acquired CSA certification. General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Dielectric strength (with sensor) ......... 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame) 50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Sensor-Purpose lead wire ..................... Brown Black Sensor Yellow Mass ...................................................... 370 g/390 g (with Sensor) Specifications Standard Model no. 109S085 109S084 109S088 109S087 109S081 109S083 109S082 109S089 109S086* Rated voltage [V] 100 115 200 230 100 115 200 230 100 Frequency [Hz] 50/60 Input [W] Current [A] 0.16/0.14 0.14/0.12 13.5/12 0.08/0.07 0.07/0.06 0.11 0.1 9.5/8.5 0.07 0.06 12/10 0.14/0.12 Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.19/0.17 0.16/0.15 2500/2900 1.95/2.3 68.9/81.3 0.1 /0.09 0.08/0.07 0.11/0.1 0.1 /0.09 2200/2350 1.7 /1.8 60.1/63.6 0.07/0.06 0.06/0.05 0.15/0.13 1400/1600 1.1 /1.25 38.9/44.2 Max. static pressure SPL [Pa] [inchHO] [dB (A)] 48 /51.9 0.193/0.216 38/41 29.4/26.5 0.118/0.106 34/35 14.7/18.6 0.059/0.075 24/27 Operating temperature Expected life -30 to +60 25000/60C [C] [h] * These are low-speed models. with Sensor For sensor specifications, please refer to p. 550. Sensor specification differs depending on the fan's speed specification. For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109S485-20 For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109S485-30 Model no. 109S485 109S484 109S488 109S487 109S486* Rated voltage [V] 100 115 200 230 100 Frequency [Hz] 50/60 * These are low-speed models. 500 Input [W] Current [A] 0.16/0.14 0.14/0.12 13.5/12 0.08/0.07 0.07/0.06 12/10 0.14/0.12 Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.19/0.17 0.16/0.15 2500/2900 1.95/2.3 68.9/81.3 0.1 /0.09 0.08/0.07 0.15/0.13 1400/1600 1.1 /1.25 38.9/44.2 Max. static pressure SPL [Pa] [inchHO] [dB (A)] 48 /51.9 0.193/0.216 38/41 14.7/18.6 0.059/0.075 24/27 Operating temperature Expected life -10 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 109S085 109S084 109S088 109S087 109S081 109S083 109S082 109S089 109S086 109S485-20 109S485-30 109S484-20 109S484-30 109S488-20 109S488-30 109S487-20 109S487-30 109S486-20 109S486-30 ST1-109S085 ST1-109S084 ST1-109S088 ST1-109S087 ST1-109S081 ST1-109S083 ST1-109S082 ST1-109S089 ST1-109S086 ST1-109S485-20 ST1-109S485-30 ST1-109S484-20 ST1-109S484-30 ST1-109S488-20 ST1-109S488-30 ST1-109S487-20 ST1-109S487-30 ST1-109S486-20 ST1-109S486-30 Voltage Low-speed sensor Plug cord* 100 V 115 V 200 V 230 V 100 V 115 V 200 V 230 V 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 489-016-L10 (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) 100 V 115 V 200 V 230 V 100 V Finger guards Mounting screws 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E M3x40 mm (4 screws) * PSE compatible. Airflow - Static Pressure Characteristics Standard (inch H2O) (Pa) (inch H2O) (Pa) 50 0.15 0.10 0.05 0 30 60 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 40 30 20 60 Hz 100 V/115 V/200 V/230 V 0.10 50 Hz 100 V/115 V/200 V/230 V 20 0.05 10 30 0.10 0.08 60 Hz 100 V 20 50 Hz 100 V 0.06 0.04 10 0.02 10 0 1 0 20 2 40 60 Airflow 3 80 100 0 (m3/min) 0 1 0 (CFM) 20 2 40 60 Airflow 3 (m3/min) 80 100 0 0 1 0 (CFM) 20 40 2 60 Airflow AC Fan 120 mm sq. 60 0.20 0.12 Static pressure 0.25 109S086 (inch H2O) (Pa) 0.15 70 Static pressure Static pressure 0.30 109S081, 109S083, 109S082, 109S089 AC 109S085, 109S084, 109S088, 109S087 (m3/min) 80 (CFM) with Sensor 109S485, 109S484, 109S488, 109S487 (inch H2O) (Pa) (inch H2O) (Pa) 70 0.25 60 0.20 50 0.15 0.10 0.05 0 0.12 60 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 40 30 20 Static pressure Static pressure 0.30 109S486 30 0.10 0.08 60 Hz 100 V 20 50 Hz 100 V 0.06 0.04 10 0.02 10 0 1 0 20 40 2 60 Airflow 3 80 100 (m3/min) (CFM) 0 0 1 0 20 40 2 60 Airflow (m3/min) 80 100 (CFM) 501 Dimensions (unit: mm) Standard 8-o3.7 Mounting hole 1190.5 104.80.5 M4 6 mm deep M4xx0.7, 0.76 Earth ground tap 104.80.5 3.5 3.5 250.5 1190.5 26 max. 26 Airflow direction Rotating direction with Sensor M4 6 mm deep 0.76 M4xx0.7, Earth ground tap 79 1190.5 104.80.3 9.5 9.5 1.5 1.5 When mounting the model with a sensor, please screw-mount through both flanges as it has a sensor box. Sensor-purpose lead wire Length 300L 300L AWG28 8-o3.7 UL 1007 Mounting hole 41 3.5 104.80.3 1190.5 3.5 25.30.5 26 max. Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 502 104.80.3 4-o4 115 104.80.3 27 4-o4 o1 115 104.80.3 o1 17 104.80.3 Wiring Diagram Standard For fan power supply AC power supply AC FAN For sensor circuit 5 V (ITEM-20) 12 V (ITEM-30) Brown Brown +4.5 to 5.5 V 100 mA max. Yellow +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) Sensor circuit with Sensor Sensor circuit AC power supply AC FAN +9.6 to 14.4 V Yellow 200 mA max. +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated. Options Resin finger guards Model no.: 109-019E, 109-019K, 109-019C, 109-019H Model no.: 109-1000G Resin filter kits Plug cord page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) page: p. 539 page: pp. 542 to 543 Model no.: 489-016-L10, 489-016-L21, 489-047-L10, 489-047-L21 AC page: p. 533 AC Fan 120 mm sq. Finger guards 503 AC Fan 120x120x38 mm San Ace 120 Certifications vary by model no. Please refer to pp. 582 to 583. General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Shaded coil motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and G terminal) Dielectric strength (with sensor) ......... 50/60 Hz 1500 VAC 1 minute (between AC input terminal and G terminal) 50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Sensor-Purpose lead wire ..................... Brown Black Sensor Yellow Mass ...................................................... 550 g/580 g (with Sensor) Specifications Standard Model no. 109S075UL 109S074UL 109S078UL 109S072UL 109S005 109S005UL 109S024 109S024UL 109S008 109S008UL 109S025 109S025UL 109S029UL 109S013 109S013UL 109S006* 109S006UL* 109S010* 109S010UL* Rated voltage [V] Frequency [Hz] 100 115 200 230 [W] 100 [A] Locked rotor current Rated speed [A] [min-1] Max. airflow [m/min] [CFM] 0.32/0.28 0.27/0.24 2700/3100 2.5 /2.9 88.3/102.5 0.16/0.14 0.14/0.13 Max. static pressure SPL [Pa] [inchHO] [dB (A)] 57.9/68.7 0.233/0.276 42/45 55.9/65.7 0.224/0.264 40/43 Operating temperature Expected life -30 to +60 25000/60C [C] [h] 0.18/0.16 0.25/0.22 120 115 0.16/0.14 0.21/0.18 14/12 200 230 Current 0.24/0.21 0.21/0.18 18/16 0.12/0.1 0.11/0.09 2700/3100 2.35/2.7 83 / 95.4 0.09/0.08 0.13/0.11 50/60 0.08/0.07 0.11/0.09 14/12 0.18/0.16 0.23/0.21 2450/2700 2.15/2.35 76 / 83 100 44.1/49.0 0.177/0.197 38/40 13/11 0.16/0.14 0.16/0.15 1800/2000 1.55/1.75 54.8/ 60.8 23.5/26.4 0.094/0.106 30/32 17.6/17.6 0.071/0.071 28/28 20 /20.6 0.08 /0.083 30/31 17.6/17.6 0.071/0.071 28/28 20.6/21.6 0.083/0.087 30/32 7/7 115 200 240 * These are low-speed models. 504 Input 0.1 /0.09 0.1 /0.09 1650/1700 1.45/1.5 51.2/ 53 10/10 0.13/0.11 0.13/0.11 1800/1900 1.56/1.64 55 / 57.9 7/7 0.05/0.04 0.05/0.04 1650/1700 1.45/1.5 51.2/ 53 11/11 0.06/0.05 0.06/0.05 1800/1950 1.58/1.68 55.8/ 59.3 with Sensor For sensor specifications, please refer to p. 550. Sensor specification differs depending on the fan's speed specification. For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109S405UL-20 For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109S405UL-30 Rated voltage Model no. [V] 109S405UL 109S424UL 109S408UL 109S425UL 109S429UL 109S406UL* 109S475UL 109S474UL 109S478UL 109S472UL Frequency Input [Hz] [W] 100 115 200 230 100 Current [A] 0.18/0.16 0.16/0.14 14/12 0.09/0.08 0.08/0.07 0.18/0.16 7/6 0.09/0.08 0.24/0.21 0.21/0.18 18/16 0.12/0.1 0.11/0.09 50/60 100 115 200 230 Locked rotor current Rated speed [min-1] [A] 0.25/0.22 0.21/0.18 0.13/0.11 0.11/0.09 0.23/0.21 0.1 /0.09 0.32/0.28 0.27/0.24 0.16/0.14 0.14/0.13 Max. airflow [m/min] [CFM] Max. static pressure SPL [Pa] [inchHO] [dB (A)] 2700/3100 2.35/2.7 83 / 95.4 55.9/65.7 0.224/0.264 40/43 2450/2700 2.15/2.35 76 / 83 1650/1700 1.45/1.5 51 / 53 44.1/49.0 17.7/17.7 0.177/0.197 0.071/0.071 38/40 28/28 2700/3100 2.5 /2.9 88.3/102.4 57.9/68.7 0.233/0.276 42/45 Operating temperature Expected life -10 to +60 25000/60C [C] [h] * These are low-speed models. For the San Ace 120AD 9AD type 120x120x38 mm fan, please refer to p. 479. This fan works while internally converting AC power into DC power, providing the superior performance of a DC fan with the flexibility of AC input. Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Voltage ST1-109S075UL ST1-109S074UL ST1-109S078UL ST1-109S072UL ST1-109S005 ST1-109S005UL ST1-109S024 ST1-109S024UL ST1-109S008 ST1-109S008UL ST1-109S025 ST1-109S025UL ST1-109S029UL ST1-109S013 ST1-109S013UL ST1-109S006 109S075UL 109S074UL 109S078UL 109S072UL 109S005 109S005UL 109S024 109S024UL 109S008 109S008UL 109S025 109S025UL 109S029UL 109S013 109S013UL 109S006 100 V 115 V 200 V 230 V ST1-109S006UL 109S006UL ST1-109S010 109S010 ST1-109S010UL 109S010UL ST1-109S405UL-20 ST1-109S405UL-30 ST1-109S424UL-20 ST1-109S424UL-30 ST1-109S408UL-20 ST1-109S408UL-30 ST1-109S425UL-20 ST1-109S425UL-30 ST1-109S429UL-20 ST1-109S429UL-30 ST1-109S406UL-20 ST1-109S406UL-30 ST1-109S475UL-20 ST1-109S475UL-30 ST1-109S474UL-20 ST1-109S474UL-30 ST1-109S478UL-20 ST1-109S478UL-30 ST1-109S472UL-20 ST1-109S472UL-30 109S405UL-20 109S405UL-30 109S424UL-20 109S424UL-30 109S408UL-20 109S408UL-30 109S425UL-20 109S425UL-30 109S429UL-20 109S429UL-30 109S406UL-20 109S406UL-30 109S475UL-20 109S475UL-30 109S474UL-20 109S474UL-30 109S478UL-20 109S478UL-30 109S472UL-20 109S472UL-30 Low-speed sensor 100 V 120 V 115 V 200 V 230 V 100 V 100 V 115 V 200 V 200 V 240 V 100 V 115 V 200 V 230 V 100 V 100 V 100 V 115 V 200 V 230 V (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) Plug cord* Finger guards 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-006-L10 489-037-L10 489-006-L10 489-037-L10 489-006-L10 489-037-L10 489-006-L10 489-037-L10 489-037-L10 489-006-L10 489-037-L10 489-006-L10 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 489-037-L10 109-019E 489-006-L10 109-019E 489-037-L10 109-019E 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 489-037-L10 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E 109-019E Mounting screws AC Fan AC Fan 120 mm sq. Order no. M3x55 mm (4 screws) * PSE compatible. 505 Airflow - Static Pressure Characteristics Standard 109S005, 109S005UL, 109S024, 109S024UL, 109S008, 109S008UL, 109S025, 109S025UL (inch H2O) (Pa) 0.30 (inch H2O) (Pa) 70 0.25 60 0.20 50 0.15 0.10 60 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 40 30 20 0.05 10 0 0 1 0 20 2 40 60 Airflow 3 Static pressure Static pressure 0.30 80 60 Hz 100 V/115 V/120 V/200 V/230 V 50 Hz 100 V/115 V/120 V/200 V/230 V 30 20 10 0 1 0 20 2 40 60 Airflow 3 60 0.20 50 0.15 0.10 0.05 0 (m3/min) 70 0.25 60 Hz 100 V 50 Hz 100 V 40 30 20 10 0 80 100 120 (CFM) 1 0 20 40 2 3 60 (m3/min) 80 100 120 (CFM) Airflow 109S006, 109S006UL, 109S010, 109S010UL (inch H2O) (Pa) 30 0.12 60 Hz 100 V 50 Hz 100 V 20 10 0 1 0 20 2 40 60 Airflow 30 0.10 Static pressure 0.10 Static pressure 0.05 0.30 40 80 100 120 (CFM) (inch H2O) (Pa) 0 50 0 (m3/min) 109S013, 109S013UL 0.05 60 0.20 0.10 (inch H2O) (Pa) 70 0.25 0.15 109S029UL Static pressure 109S075UL, 109S074UL, 109S078UL, 109S072UL 20 0.06 0.04 10 0.02 0 3 (m3/min) 80 100 0.08 60 Hz 115 V/240 V 50 Hz 115 V/240 V 60 Hz 100 V/200 V 50 Hz 100 V/200 V 0 0.5 1.0 1.5 2.0 (m3/min) 0 10 20 30 40 50 60 70 (CFM) Airflow (CFM) with Sensor (inch H2O) (Pa) 60 0.20 50 0.10 0.05 0 50 Hz 100 V/115 V/200 V/230 V 40 30 20 10 0 1 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) 109S475UL, 109S474UL, 109S478UL, 109S472UL (inch H2O) (Pa) 0.35 Static pressure 80 70 0.25 60 0.20 50 0.15 40 0.10 60 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 30 20 0.05 10 0 0 1 0 506 (inch H2O) (Pa) 0.30 60 Hz 100 V/115 V/200 V/230 V 0 0.30 (inch H2O) (Pa) 70 0.25 0.15 109S406UL 20 40 2 60 Airflow 3 (m3/min) 80 100 (CFM) Static pressure Static pressure 0.30 109S429UL 70 0.25 60 0.20 50 0.15 0.10 0.05 0 0.12 50 Hz 100 V 40 30 20 10 0 1 0 20 40 2 60 Airflow 30 0.10 60 Hz 100 V Static pressure 109S405UL, 109S424UL, 109S408UL, 109S425UL 3 (m3/min) 80 100 (CFM) 0.08 20 0.06 0.04 10 60 Hz 100 V 0.02 0 50 Hz 100 V 0 0.5 0 10 20 1.0 30 Airflow 40 1.5 50 (m3/min) 60 (CFM) Dimensions (unit: mm) Standard 1190.8 104.80.3 6.80.3 380.5 (4) 6.50.3 (4) 1190.8 104.80.3 AIRFLOW Rotating direction 8-o3.7 Mounting hole with Sensor Airflow direction When mounting the model with a sensor, please screw-mount through both flanges as it has a sensor box. 380.5 1190.8 6.80.3 (4) 104.80.3 1190.8 104.80.3 Sensor-purpose lead wire 300L Length 300L AWG AWG28 28 UL 1007 UL 1007 6.50.3 (4) AIRFLOW 8-o3.7 Mounting hole Rotating direction Airflow direction 4-o4 115 4-o4 AC Fan 120 mm sq. 115 104.80.3 27 104.80.3 104.80.3 o1 17 104.80.3 Outlet side o1 Inlet side AC Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) 507 Wiring Diagram Standard For fan power supply AC power supply AC FAN For sensor circuit 5 V (ITEM-20) 12 V (ITEM-30) Brown Brown +4.5 to 5.5 V 100 mA max. Yellow +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) Sensor circuit with Sensor Sensor circuit AC power supply AC FAN +9.6 to 14.4 V Yellow 200 mA max. +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated. Options Finger guards page: p. 533 Resin finger guards Model no.: 109-019E, 109-019K, 109-019C, 109-019H Model no.: 109-1000G Resin filter kits Filter kits page: p. 540 Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI) Model no.: 109-018 Screen kits Plug cord Model no.: 109-020 page: p. 541 page: p. 529 page: p. 541 page: pp. 542 to 543 Exclusive for fans without UL at the end of the model number. Model no.: 489-006-L10, 489-006-L21, 489-006-L35 Exclusive for fans with UL at the end of the model number. Model no.: 489-037-L10, 489-037-L21, 489-037-L35, 489-007-L10, 489-007-L21 508 AC Fan 160x160x51 mm San Ace 160 Only standard fans (without sensors) have acquired CSA certification. General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Capacitor motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Dielectric strength (with sensor) ......... 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame) 50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Sensor-Purpose lead wire ..................... Brown Black Sensor Yellow Mass ...................................................... 1100 g Specifications Standard Rated voltage [V] 100 115 200 230 109-601 109-604 109-602 109-603 Frequency [Hz] 50/60 Input [W] Current [A] 0.43/0.35 0.39/0.31 37.5/33 0.23/0.18 0.21/0.16 Locked rotor current Rated speed [A] [min-1] 0.72/0.7 0.62/0.61 2850/3350 0.36/0.35 0.32/0.31 Max. airflow [m/min] [CFM] Max. static pressure [Pa] 7.2/8.5 254.4/300.4 156.8/166.6 [inchHO] [dB (A)] SPL Operating temperature Expected life 0.63/0.669 56/60 -30 to +60 25000/60C [C] [h] AC with Sensor For sensor specifications, please refer to p. 550. Sensor specification differs depending on the fan's speed specification. For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109-641-20 For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109-641-30 Model no. Rated voltage 109-641 109-644 109-642 109-643 [V] 100 115 200 230 Frequency [Hz] 50/60 Input [W] Current [A] 0.43/0.35 0.39/0.31 37.5/33 0.23/0.18 0.21/0.16 Locked rotor current Rated speed [A] [min-1] 0.72/0.7 0.62/0.61 2850/3350 0.36/0.35 0.32/0.31 Max. airflow [m/min] [CFM] Max. static pressure [Pa] 7.2/8.5 254.4/300.4 156.8/166.6 [inchHO] [dB (A)] SPL Operating temperature Expected life 0.63/0.669 56/60 -10 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Order no. ST1-109-601 ST1-109-604 ST1-109-602 ST1-109-603 ST1-109-641-20 ST1-109-641-30 ST1-109-644-20 ST1-109-644-30 ST1-109-642-20 ST1-109-642-30 ST1-109-643-20 ST1-109-643-30 Set items Fan Voltage 109-601 109-604 109-602 109-603 109-641-20 109-641-30 109-644-20 109-644-30 109-642-20 109-642-30 109-643-20 109-643-30 100 V 115 V 200 V 230 V 100 V 115 V 200 V 230 V Low-speed sensor (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) Plug cord* 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 489-1618-L10 Finger guards 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E 109-619E Mounting screws M5x20 mm (4 screws) * PSE compatible. 509 AC Fan 160 mm sq. Model no. Airflow - Static Pressure Characteristics Standard with Sensor 109-601, 109-604, 109-602, 109-603 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 1 2 3 4 5 6 7 8 9 0 Static pressure Static pressure (inch H2O) (Pa) 109-641, 109-644, 109-642, 109-643 (m3/min) 0.8 200 0.6 150 60 Hz 100 V/115 V/200 V/230 V 0.4 100 50 Hz 100 V/115 V/200 V/230 V 0.2 50 0 0 50 100 150 200 250 300 350 (CFM) 1 2 3 4 5 6 7 8 9 0 Airflow (m3/min) 50 100 150 200 250 300 350 (CFM) Airflow Dimensions (unit: mm) Standard +1 51 0 +1 160 0 138.50.3 8-o5.5 Mounting hole 28 28 max. (4) +1 160 0 138.50.3 M4x0.7, 5 mm deep M4x0.75 Earth ground tap ROTATION AIRFLOW Airflow direction Rotating direction with Sensor +1 51 0 +1 160 0 138.50.3 28 max. 28 138.50.3 8-o5.5 Mounting hole (4) (4) M4x0.7, 5 mm deep M4x0.75 Earth ground tap AIRFLOW ROTATION +1 160 0 (4) Sensor-purpose lead wire Length 300L 300L AWG28 AWG28 UL 1007 UL 1007 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 157 138.50.3 75 o1 510 157 4-o5.7 138.50.3 Wiring Diagram Standard For fan power supply AC power supply AC FAN For sensor circuit 5 V (ITEM-20) 12 V (ITEM-30) Brown Brown +4.5 to 5.5 V 100 mA max. Yellow +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) Sensor circuit with Sensor Sensor circuit AC power supply AC FAN +9.6 to 14.4 V Yellow 200 mA max. +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated. Options Plug cord page: pp. 542 to 543 Model no.: 489-084-L10, 489-084-L21, 489-086-L10, 489-086-L21, 489-1618-L10, 489-1618-L21, 489-1618-L28, 489-1619-L10, 489-1619-L21 AC Model no.: 109-619E, 109-619H, 109-620 page: p. 533 AC Fan 160 mm sq. Finger guards 511 AC Fan o 172x150x51 mm San Ace 172 Sidecut type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Capacitor motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Mass ...................................................... 1000 g Specifications Rated voltage Model no. [V] 100 115 200 230 109S301 109S304 109S302 109S303 Frequency Input [Hz] [W] Current [A] 0.33/0.25 0.29/0.22 27/25 0.16/0.13 0.14/0.11 50/60 Locked rotor current Rated speed [A] [min-1] 0.65/0.64 0.55/0.54 2900/3500 0.33/0.32 0.28/0.27 Max. airflow [m/min] [CFM] 5.3/6.4 187.3/226.1 Max. static pressure [Pa] [inchHO] [dB (A)] SPL Operating temperature Expected life 147/196 0.59/0.787 51/56 -30 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan 109S301 109S304 109S302 109S303 ST1-109S301 ST1-109S304 ST1-109S302 ST1-109S303 Voltage 100 V 115 V 200 V 230 V Low-speed sensor Plug cord* 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 * PSE compatible. ** Though these are 2-hole or 3-hole frame mount types, 4 screws are included for extra. Airflow - Static Pressure Characteristics 109S301, 109S304, 109S302, 109S303 (inch H2O) (Pa) 0.8 200 0.6 150 0.4 100 0.2 50 0 0 Static pressure 60 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 2 0 512 4 6 8 (m3/min) 50 100 150 200 250 300 (CFM) Airflow Finger guards 109-319E 109-319E 109-319E 109-319E Mounting screws M4x25 mm (4 screws)** Dimensions (unit: mm) M4x0.7, 5 mm deep 0.75 Earth ground tap 4-o4.3 Mounting hole 1620.5 o1720.8 AIRFLOW ROTATION (7.5) (7.5) 1500.8 510.8 Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side AC 2- R4 .25 1620.3 o1 68 148 AC Fan o172 mm 2-o4.5 8.5 Wiring Diagram AC power supply AC FAN Options Finger guards Model no.: 109-319E, 109-319H, 109-320 page: p. 534 Plug cord page: pp. 542 to 543 Model no.: 489-1619-L10, 489-1619-L21, 489-084-L10, 489-084-L21 513 AC Fan o 172x51 mm San Ace 172 Only standard fans (without sensors) have acquired CSA certification. Round type General Specifications Material ................................................ Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life .......................................... See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure .................................... Capacitor motor Motor protection function ..................... Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength ................................. 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Dielectric strength (with sensor) ......... 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame) 50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame) Insulation resistance.............................. 10 M or more with a 500 VDC megger Sound pressure level (SPL) .................. At 1 m away from the air inlet Operating voltage range ..................... Voltage of each model 10% Storage temperature ........................... -30 to +70C (Non-condensing) Sensor-Purpose lead wire ..................... Brown Black Sensor Yellow Mass ...................................................... 1000 g Specifications Standard Model no. Rated voltage [V] 100 115 200 230 109-311 109-314 109-312 109-313 Frequency [Hz] 50/60 Input [W] Current [A] 0.33/0.25 0.29/0.22 27/25 0.16/0.13 0.14/0.11 Locked rotor current Rated speed [A] [min-1] 0.65/0.64 0.55/0.54 2900/3500 0.33/0.32 0.28/0.27 Max. airflow [m/min] [CFM] 5.3/6.4 187.3/226.1 Max. static pressure [Pa] [inchHO] [dB (A)] SPL Operating temperature Expected life 147/196 0.59/0.787 47/51 -30 to +60 25000/60C [C] [h] with Sensor For sensor specifications, please refer to p. 550. Sensor specification differs depending on the fan's speed specification. For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109-371-20 For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109-371-30 Model no. Rated voltage 109-371 109-374 109-372 109-373 [V] 100 115 200 230 Frequency [Hz] 50/60 Input [W] Current [A] 0.33/0.25 0.29/0.22 27/25 0.16/0.13 0.14/0.11 Locked rotor current Rated speed [A] [min-1] 0.65/0.64 0.55/0.54 2900/3500 0.33/0.32 0.28/0.27 Max. airflow [m/min] [CFM] 5.3/6.4 187.3/226.1 Max. static pressure [Pa] [inchHO] [dB (A)] SPL Operating temperature Expected life 147/196 0.59/0.787 47/51 -10 to +60 25000/60C [C] [h] Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Order no. ST1-109-311 ST1-109-314 ST1-109-312 ST1-109-313 ST1-109-371-20 ST1-109-371-30 ST1-109-374-20 ST1-109-374-30 ST1-109-372-20 ST1-109-372-30 ST1-109-373-20 ST1-109-373-30 * PSE compatible. 514 Set items Fan Voltage 109-311 109-314 109-312 109-313 109-371-20 109-371-30 109-374-20 109-374-30 109-372-20 109-372-30 109-373-20 109-373-30 100 V 115 V 200 V 230 V 100 V 115 V 200 V 230 V Low-speed sensor (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) (5 V) (12 V) Plug cord* 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 489-1619-L10 Finger guards 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E 109-319E Mounting screws M4x25 mm (4 screws) Airflow - Static Pressure Characteristics Standard with Sensor 109-311, 109-314, 109-312, 109-313 109-371, 109-374, 109-372, 109-373 0.8 200 0.6 150 0.4 100 0.2 50 0 0 (inch H2O) (Pa) 0.8 200 0.6 150 0.4 100 0.2 50 0 0 60 Hz 100 V/115 V/200 V/230 V 60 Hz 100 V/115 V/200 V/230 V Static pressure Static pressure (inch H2O) (Pa) 50 Hz 100 V/115 V/200 V/230 V 2 0 4 6 8 (m3/min) 50 100 150 200 250 300 Airflow 50 Hz 100 V/115 V/200 V/230 V 2 0 (CFM) 4 6 8 (m3/min) 50 100 150 200 250 300 (CFM) Airflow Dimensions (unit: mm) with Sensor 10.80.4 7.50.4 ROTATION M4 5 mm deep M4xx0.7, 0.75 Earth ground tap ROTATION 300L 8-o4.3 Mounting hole Rotating direction (7.5) (7.5) 510.8 Airflow direction Sensor-purpose lead wire Length 300L 300L AWG28 AWG28 UL 1007 1007 8-o4.3 Mounting hole 72 1620.5 Rotating direction (7.5) (7.5) 510.8 Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4- R4 .25 1620.3 o1 68 1620.3 8.5 4-o4.5 515 AC Fan o172 mm AC 78 o1720.8 1620.5 o1720.8 1620.5 AIRFLOW M4x0.7, 5 mm deep 0.75 Earth ground tap AIRFLOW 10.80.4 7.50.4 Standard Wiring Diagram Standard For fan power supply AC power supply AC FAN For sensor circuit 5 V (ITEM-20) 12 V (ITEM-30) Brown Brown +4.5 to 5.5 V 100 mA max. Yellow +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) Sensor circuit with Sensor Sensor circuit AC power supply AC FAN +9.6 to 14.4 V Yellow 200 mA max. +27.6 V max. Pull-up resistor Black Sensor output GND (0 V) GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated. Options Finger guards page: p. 534 Model no.: 109-319E, 109-319H, 109-320, 109-1066, 109-1068 516 Plug cord page: pp. 542 to 543 Model no.: 489-1619-L10, 489-1619-L21, 489-084-L10, 489-084-L21 517 AC Fan o172 mm AC PWM Controller Features Reduces system power consumption and fan noise For PWM fan speed control, a PWM control circuit needs to be newly designed and configured. By using this product, however, PWM control function fans can be fully utilized without the need for preparing new circuits, contributing to reducing the system power consumption and the fan noise. Can be common-powered by the fan power supply The controller can be powered by the fan power supply of rated voltage 12, 24, and 48 VDC, and no separate supply is required. Maximum of four fans connectable Box type Up to four fans with PWM control function can be connected and controlled. PCB type Specifications Model no. Size [mm] Rated voltage [V] Power consumption [W] Operating temperature [C] Input voltage range [V] (V+, V-) Input terminal Control voltage range [V] PWM signal output PWM frequency [kHz] Output Output current terminal Output breakdown voltage [V] No. of connectable fans Control functions** Mounting method Mass [g] Material Box type PCB type 9PC8666X-S001 9PC8045D-V001 9PC8045D-R001 9PC8045D-T001 80 (H) x 45 (W) x 17 (D) 86 (H) x 66 (W) x 38 (D) 12/24/48 0.2* -20 to +70 7 to 60 0 to 5.5 VOH (high level voltage): 3.3 or 5 VDC selectable 25 20 mA max. (total sum of 4 terminals) 6.5 Up to 4 fans Voltage control, Internal adjustment (variable Variable resistor Thermistor resistor) control, External adjustment (variable Voltage control control*** control*** resistor) control***, Thermistor control*** DIN rail mounting or screw mounting Screw mounting 110 27 Case: Plastic PCB: FR-4 * When output terminals are turned on. ** Control functions are mutually exclusive for Box type. *** Variable resistor and thermistor are not supplied with the controller and need to be prepared separately. Be noted that if applied input voltage or frequency is out of range of the connected fan, how the fan speed responds to the PWM duty cycle may be altered. Front View (component names) * Box type * PCB type Temperature selector switch Ground terminal Power supply input terminal Thermistor connection terminals (for thermistor control model only) Control voltage ground or variable resistor connection terminal Control voltage input terminal Variable resistor connection terminals Control function selector switch PWM output voltage switch VOHVselector PWM OH Input terminals PWM output terminals PWM signal Adjustment knob PWM PWM output voltage OH selector switch VVOH 518 PWM signal output terminals PWM Connection Examples and PWM Signal Output Characteristics Controller can be common-powered by the power supply for 12, 24, and 48 VDC rated voltage fans. It can also be powered by a separate supply as long as both supplies share the same ground. Voltage control Output duty cycle controlled with input voltage of 0 to 5 VDC. *Ensure that the input voltage does not exceed 5.5 VDC. * Box type DC power supply + GND Control Voltage Output Duty Cycle Characteristics Control voltage + GND (%) 100 PWM signal Output duty cycle 80 * PCB type (Model no.: 9PC8045D-V001) 60 40 20 0 1 2 3 4 5 (VDC) Control voltage + GND DC power supply + GND Control voltage PWM signal Internal adjustment (variable resistor) control Output duty cycle controlled with the adjustment knob. PWM Controller * Box type Inner Scale Reading Output Duty Cycle Characteristics DC power supply + GND (%) 100 Output duty cycle 75 50 25 PWM signal Output duty cycle controlled with the adjustment knob (on the inner scale) 0 25 50 75 100 (%) Inner scale reading with adjustment knob 519 PWM Controller External adjustment (variable resistor) control Output duty cycle controlled with variable resistor connected to terminals. * Box type DC power supply + GND Resistance Output Duty Cycle Characteristics Recommended total resistance: 10 k Resistance taper: B (linear curve fitting) (%) 100 Variable resistor PWM signal * PCB type (Model no.: 9PC8045D-R001) Output duty cycle 80 60 40 20 0 1 2 3 4 5 6 7 8 9 10 (k) Resistance + GND DC power supply PWM signal Variable resistor Thermistor control Automation control of output duty cycle in response to the temperature detected with an external thermistor. * Box type DC power supply + GND Controlling Conditions TST: Temperature set with the adjustment knob (30 to 50C) TTH: Temperature detected with thermistor Recommended thermistor conditions Type: NTC R25 (Resistance at 25C): 10 k B value: B25/85 = 3435 K Thermistor Temperature conditions Target temperature can be set with the adjustment knob (on the outer scale) PWM signal * PCB type (Model no.: 9PC8045D-T001) Target temperature selected with switch PWM signal + GND DC power supply 520 Thermistor Duty cycle Fan rotational speed (For reference) TST TTH Increases Increases TST TTH Decreases Decreases TST TTH Maintained Maintained Dimensions (unit: mm) * Box type Front view Side view 4-o3.50.3 Mounting hole (39 max.) 39 Back view 661 570.5 35.50.5 861 361 (4) 250.5 770.5 DIN rail base section DIN DIN rail clip DIN * PCB type Front view Side view 13 max. 800.5 2.5 max. 700.3 Temperature setting selector switch (Only for9PC8045D-T001 model no.: 9PC8045D-T001) 0 7 1 6 2 PWM output PWM voltage VOH selector switch OH 4-o3.50.3 PWM Controller 390.3 4 450.5 5 3 ON (1.6) 521 PWM Controller Safety Precautions Box type To ensure that the product is used safely, be sure to read and fully understand the Safety Precautions and only use the product as directed. Read the Safety Precautions carefully before installing, connecting, operating, maintaining, or inspecting the product. The product has been designed and manufactured for use in general industrial machinery, and may not be used as a standalone product. The product of our company (hereafter referred to as "the product") falls into the category of the products specified in the Attached List 1, Item 16 (Class 85, Item 43) of the Export Trade Control Ordinance. To export the product as an individual part or to export a device into which the product is assembled, the Information Requirements and Objective Requirements that the Ministry of Economy, Trade and Industry established based on the Catchall Controls must be studied for applicability. Based on information on applicability and specified requirements, appropriate export procedures must be taken. When disposing of the product, treat it as industrial waste. For instructions on proper disposal methods, please contact local government authorities. When using the product in an environment with vibration, such as in a car or a ship, use it at your own discretion only after deploying sufficient safety measures and making prior evaluations. Fully understand the Safety Precautions described in this instruction manual before using the product. In order to prevent any possible bodily injury or damage to property or equipment, the following precautions for ensuring safety are displayed according to the following two ranks of importance: Danger Handling or using the product improperly and in disregard of the instructions with this mark may result in serious bodily injury or death. Caution Handling or using the product improperly and in disregard of the instructions with this mark may result in bodily injury or physical damage. * Items marked Caution may also result in serious bodily injury or death in some circumstances. Always follow the instructions for items marked Danger. Danger If the product is used in medical appliances or other types of equipment that affect people's lives, sufficient safety-related evaluations and preparations must be made in advance, and the product or the type of equipment into which the product is assembled must be used under the full responsibility of the user. If the product is used in types of equipment that have a strong social and public impact, sufficient prior evaluations and safety-related evaluations and preparations must be made, and the product or the type of equipment into which the product is assembled must be used under the full responsibility of the user. The product is not designed to be used in a car or a ship. When using the product in an environment with vibration, such as in a car or a ship, use it at your own discretion only after deploying sufficient safety measures and making prior evaluations. Connect all wires properly and securely. Failure to do so may result in fire, burns, or electrical shock. Do not use the product in a location where there is flammable gas. Otherwise, it may result in fire, burns, or bodily injury. Do not operate the product when electronic components are exposed. Otherwise, it may result in electrical shock. Turn off the power and stop using the product immediately if you notice any sparks, smoke, odd odors, sounds, or anything unusual during operation. Failure to do so may result in fire, bodily injury, or electrical shock. Never allow the product to fall, topple over, or otherwise be subjected to excessive shocks when moving it. Otherwise, it may result in product failure. The product should be handled only by personnel with sufficient training and knowledge and under the full responsibility of the user. Never attempt to disassemble, repair, or alter the product in any way, as doing so may result in fire, burns, or electrical shock. Caution Handling Installation, placement, connections, wiring, or relocation of the product should be performed by knowledgeable or correctly licensed personnel. Never perform such work while the product is on. Failure to do so may result in bodily injury, fire, burns, or electrical shock. Never allow yourself to come into contact with the ends of wires or plugs when measuring insulation resistance or dielectric strength voltage. Otherwise, it may result in electrical shock. Never attempt to disassemble or alter the product in any way. Doing so may invalidate any warranties concerning the functions or performance of the product, and may also result in fire, burns, bodily injury, or electrical shock. Instruction Take measures to protect the device from potential damage caused by the product stopping during operation. Never use the product at voltages, temperatures, or any other settings which exceed those given in the product specifications. Otherwise, it may result in substandard operation, failure, fire, bodily injury, or electrical shock. Never remove the product nameplate or install the product so that the identification cannot be seen after installation. Otherwise, it may result in the product being improperly used, and subsequently result in fires. Do not turn the power supply ON/OFF on a ground wire. Otherwise, it may result in product failure. Do not apply excessive force to the product while it is operating. Otherwise, it may result in product failure. If you install and use the product in a car or a ship, we shall not be responsible for any faults caused by the environment of the car or ship in which the product is installed. Installation When fixing the product into place, be sure to take into consideration the product's weight and all other relevant factors. Failure to do so may result in the product or its parts falling, resulting in bodily injury or device failure. Never install or remove the product while it is wired. When fixing the product with screws, ensure correct tightening torque. If the tightening torque is over the recommended values, the product structure may deform or break. Take proper precautions against static electricity when making electrical connections. Failure to do so may result in device or product failure. Make electrical connections properly. Failure to do so may result in device failure, product failure, or product malfunction. Ensure that wires are fitted with insulation to prevent accidental short-circuiting. Failure to do so may result in device failure, product failure, or product malfunction. Operating environment Do not use or store the product where it is exposed to flammable or corrosive gas, water or oil splashes, dust or humidity, condensation, radioactive rays or direct sunlight, salty air or saltwater, or where the product may be contaminated by corrosive materials such as sulfurous water, sulfurous volcanic ash, organic solvents, acidic chemicals, alkali chemicals, nuclear fuel materials, or other hazardous substances. If it is used or stored in such places or environments, there is the possibility that a fire may occur, the product may malfunction or its performance may deteriorate. Do not use or store the product in locations and environments where it could be constantly exposed to vibrations, strong shocks, magnetic or electromagnetic noise, or in which electromagnetic noise overlaps into power voltage. Otherwise, it may result in product failure. Do not use or store the product in environments subject to sudden changes in temperature and humidity. Otherwise, it may result in product failure. Maintenance Only certified personnel with sufficient training and knowledge should perform maintenance and inspections. Otherwise, it may result in fire, burns, bodily injury, or electrical shock. Perform maintenance or inspections while the product is off. Otherwise, it may result in fire, burns, bodily injury, or electrical shock. Never use gasoline, paint thinner, benzene, or any other organic solvents to clean the product. Otherwise, it may result in product deformation or substandard operation. 522 PCB type To ensure that the product is used safely, be sure to read and fully understand the Safety Precautions and only use the product as directed. Read the Safety Precautions carefully before installing, connecting, operating, maintaining, or inspecting the product. The product has been designed and manufactured for use in general industrial machinery, and may not be used as a standalone product. The product of our company (hereafter referred to as "the product") falls into the category of the products specified in the Attached List 1, Item 16 (Class 85, Item 43) of the Export Trade Control Ordinance. To export the product as an individual part or to export a product into which the product is assembled, the Information Requirements and Objective Requirements that the Ministry of Economy, Trade and Industry established based on the Catchall Controls must be studied for applicability. Based on information on applicability and specified requirements, appropriate export formalities must be performed. When disposing of the product, treat it as industrial waste. For instructions on proper disposal methods, please contact local government authorities. When using the product in an environment with vibration, such as in a car or a ship, use it at your own discretion only after deploying sufficient safety measures and making prior evaluations. Fully understand the Safety Precautions described in this instruction manual before using the product. In order to prevent any possible bodily injury or damage to property or equipment, the following precautions for ensuring safety are displayed according to the following two ranks of importance: Danger Handling or using the product improperly and in disregard of the instructions with this mark may result in serious bodily injury or death. Caution Handling or using the product improperly and in disregard of the instructions with this mark may result in bodily injury or physical damage. * Items marked Caution may also result in serious bodily injury or death in some circumstances. Always follow the instructions for items marked Danger. Danger If the product is used in medical appliances or other types of equipment that affect people's lives, sufficient safety-related evaluations and preparations must be made in advance, and the product or the type of equipment into which the product is assembled must be used under the full responsibility of the user. If the product is used in types of equipment that have a strong social and public impact, sufficient prior evaluations and safety-related evaluations and preparations must be made, and the product or the type of equipment into which the product is assembled must be used under the full responsibility of the user. The product is not designed to be used in a car or a ship. When using the product in an environment with vibration, such as in a car or a ship, use it at your own discretion only after deploying sufficient safety measures and making prior evaluations. Connect all wires properly and securely. Failure to do so may result in fire, burns, or electrical shock. Do not use this product in a location where there is flammable gas. Otherwise, it may result in fire, burns, or bodily injury. Only use the product integrated with another device or system. Failure to do so may result in burns or electrical shock. Do not touch the product while it is operating. Otherwise, it may result in burns or electrical shock. Turn off the power and stop using the product immediately if you notice any sparks, smoke, odd odors, sounds, or anything unusual during operation. Failure to do so may result in fire, bodily injury, or electrical shock. Never allow the product to fall, topple over, or otherwise be subjected to excessive shocks when moving it. Otherwise, it may result in product failure. The product should be handled only by personnel with sufficient training and knowledge and under the full responsibility of the user. Never attempt to disassemble, repair, or alter the product in any way. Failure to do so may result in fire, bodily injury, or electrical shock. Caution Handling Discharge static electricity from your body before handling the product. In addition, avoid packaging or covering the product with materials which generate static electricity. Contact with static electricity may result in product failure. Do not touch solder joints or pins. Otherwise, it may result in bodily injury. Installation, placement, connections, wiring, or relocation of the product should be performed by knowledgeable or correctly licensed personnel. Never perform such work while the product is on. Failure to do so may result in bodily injury, fire, burns, or electrical shock. Never allow yourself to come into contact with the ends of wires or plugs when measuring insulation resistance or dielectric strength voltage. Otherwise, it may result in electrical shock. Never attempt to disassemble or alter the product in any way. Doing so may invalidate any warranties concerning the functions or performance of the product, and may also result in fire, burns, bodily injury, or electrical shock. Do not touch the product for a period after the power has been turned off as it may still be hot. Otherwise, it may result in burns. Take measures to protect the device from potential damage caused by the product stopping during operation. Never use the product at voltages, temperatures, or any other settings which exceed those given in the product specifications. Otherwise, it may result in substandard operation, failure, fire, bodily injury, or electrical shock. Never remove the product nameplate or install the product so that the identification cannot be seen after installation. Otherwise, it may result in the product being improperly used, and subsequently result in fires. Do not turn the power supply ON/OFF on a ground wire. Otherwise, it may result in product failure. Do not apply excessive force to the product while it is operating. Otherwise, it may result in product failure. If you install and use the product in a car or a ship, we shall not be responsible for any faults caused by the environment of the car or ship in which the product is installed. Installation When fixing the product into place, be sure to take into consideration the product's weight and all other relevant factors. Failure to do so may result in the product or its parts falling, resulting in bodily injury or device failure. Never install or remove the product while it is wired. When fixing the product with screws, ensure correct tightening torque. If the tightening torque is over the recommended values, the product structure may deform or break. Install the product carefully without touching conductors or other electrical components. Touching these components may result in device failure, product failure, or product malfunction. Take proper precautions against static electricity when making electrical connections. Failure to do so may result in device or product failure. Make electrical connections properly. Failure to do so may result in device failure, product failure, or product malfunction. Ensure that wires are not allowed to short-circuit. Failure to do so may result in device failure, product failure, or product malfunction. Operating environment Do not use or store the product where it is exposed to flammable or corrosive gas, water or oil splashes, dust or humidity, condensation, radioactive rays or direct sunlight, salty air or saltwater, or where the product may be contaminated by corrosive materials such as sulfurous water, sulfurous volcanic ash, organic solvents, acidic chemicals, alkali chemicals, nuclear fuel materials, or other hazardous substances. If it is used or stored in such places or environments, there is the possibility that a fire may occur, the product may malfunction or its performance may deteriorate. Do not use or store the product in locations and environments where it could be constantly exposed to vibrations, strong shocks, magnetic or electromagnetic noise, or in which electromagnetic noise overlaps into power voltage. Otherwise, it may result in product failure. Do not use or store the product in environments subject to sudden changes in temperature and humidity. Otherwise, it may result in product failure. Maintenance Only certified personnel with sufficient training and knowledge should perform maintenance and inspections. Otherwise, it may result in fire, burns, bodily injury, or electrical shock. Perform maintenance or inspections while the product is off. Otherwise, it may result in fire, burns, bodily injury, or electrical shock. Never use gasoline, paint thinner, benzene, or any other organic solvents to clean the product. Otherwise, it may result in product deformation or substandard operation. 523 PWM Controller Instruction Airflow Tester Features measuring device airflow and system impedance) (Patented as a movable measurement device for Enables the selection of the optimal fan for a device An optimal fan for a device can be selected by entering accurate measurement results into thermal design simulation software. Compact and lightweight With a compact design and weight of approximately 6 kg, it is portable enough to measure immobile equipment. Measurement Functions System Impedance Operating Airflow P-Q Performance Measurement of the resistance to the flow of air within a device Measurement of the actual airflow that passes through a device when a fan is mounted Measurement of airflow versus static pressure characteristics* With connection duct mounted * Performance curve that illustrates the characteristics of a fan for use within a certain system. It shows the relationship between airflow and static pressure. Specifications Model no. Measurement Airflow units Static pressure Measurement Airflow range Static pressure Measurement Airflow accuracy Static pressure Operating environment Ambient temperature Humidity Display Interface Power supply Input voltage Power consumption Dimensions Mass Included peripherals 9AT2560S-000* 9AT2560A-000* 3 m /min CFM Pa inchH2O 0.20 to 8.00 m3/min 7 to 282 CFM 0 to 1000 Pa 0 to 4.01 inchH2O 7% of maximum measurable airflow with each nozzle 10 Pa (0.04 inchH2O) for measurement results < 200 Pa, 50 Pa (0.20 inchH2O) for measurement results 200 Pa 0 to 40C 9AT2560C-000* CFM Pa 7 to 282 CFM 0 to 1000 Pa 20 to 85% RH (non-condensing) Data no., Measurement values (airflow, static pressure**), Measurement status, Nozzle selection, Measurement mode selection Digital output: Included USB serial adapter 100 to 240 VAC50/60 Hz 260 VA max. 600 (W) x 250 (H) x 250 (D) mm Main unit: Approx. 6 kg, Connection duct (including board holder): Approx. 1.5 kg 1 Set of measurement nozzles, Plastic mounting board (5 pcs / set), Connection duct, AC power cable (2.5 m), USB serial adapter, Instruction manual, Quick start guide, Data viewer software * The AC power plug shape differs with the number in of model numbers. AC power plug included in models with 1 in is for Japan and North America regions (2 parallel flat pins + a round grounding pin), Input voltage: 100/120 VAC, 50/60 Hz AC power plug included in models with 2 in is for Europe region (2 round pins + a female grounding contact), Input voltage: 220 VAC, 50 Hz AC power plug included in models with 3 in is for China region (2 angled flat pins + a flat grounding pin), Input voltage: 220 VAC, 50 Hz Product also available without an AC power cable. Model no. 9AT2560S-0000, 9AT2560A-0000, 9AT2560C-0000 ** Static pressure values are calculated with standard atmosphere as 1013 hPa at 20C. 524 Airflow Tester Part Names view Top B Side view B Control panel Front view (air inlet side) A Side view A Carrying handle A Side view A Back view (air outlet side) PC Serial port Power switch AC AC socket Mode selection valves Air inlet Auxiliary fan B Side view B Nozzle slot No. Data No. Airflow Airflow Tester Control panel (zoomed in) Static pressure Status indicator Nozzle selection button Start/Stop button Mode selection button Mode selection indicator Nozzle selection indicator 525 Airflow Tester Usage Examples Cut out a hole in the mounting board matching the vent opening of the device to be measured, and place the mounting board firmly against the device to perform measurements. Device to be measured Device to be measured Vent Connection Vent duct Plastic mounting board Data Viewer Software (included) Obtained measurement data can be represented as a graph and saved on a PC. Screen examples P-Q performance shown below based on catalog data. Option Carrying case Measurement nozzle case included 9AT2560-B001 Please add "CS" to the end of the model no. of Airflow Tester in page 1 when ordering Airflow Tester and carrying case as a set. e.g. 9AT2560S-0001CS Dimensions 705 (W) x 385 (H) x 415 (D) mm Model no. Carrying case, measurement nozzle case 526 Plastic mounting boards Sized to fit the duct frame. Five boards included with Airflow Tester. 9AT2560-P001 Model no. 5 pcs / set Quantity Dimensions 525 (W) x 275 (H) x 4 (D) mm Plastic mounting boards (5 pcs) Dimensions (unit: mm) * Main unit Top view B Side view B Airflow direction A Side view A Front view (air inlet side) Back view (air outlet side) A Side view A 170 220 600 186 250 186 140 170 140 Bottom view UNC 1/4"-20 screw 1/4-20UNC * Connection duct Airflow Tester Side view B B 552 273 177 302 250 500 177 527 Airflow Tester Safety Precautions Please read the instruction manual and its appendix carefully prior to installation, operation, maintenance or inspection and perform all tasks according to the instructions provided here. A good understanding of this equipment, its safety information as well as all Warnings/Cautions is also necessary prior to operation. Matters that require attention are ranked as Danger", Warning", and Caution in this document. Warning symbols Warning Denotes immediate hazards which could cause severe bodily injury or death as a result of incorrect operation. Caution Denotes hazards which could cause bodily injury and product or property damage as a result of incorrect operation. Caution Even those hazards denoted by this symbol could lead to a serious accident. Make sure to strictly follow these safety precautions. Prohibited, mandatory symbols Indicates actions that must not be allowed to occur / prohibited actions. Indicates actions that must be carried out / mandatory actions. Warning Operating precautions Avoid using the product in the presence of flammable, explosive, or corrosive gases, locations subjected to splashing water or oil, or near combustibles. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. Turn off the power before performing any wiring, maintenance, or inspection. Once the power is off, remove the AC power cable, and confirm that the POWER LED is off before performing these tasks. Failure to do so may result in electric shock. Operate the product with dry hands. Failure to do so may result in electric shock. Never attempt to disassemble or alter the product in any way. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. Do not damage the AC power cable. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. If the product emits unusual noise, odors, or smoke, or if water or other liquids enter the product, immediately turn off the power and disconnect the power cable. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. Read the instruction manual carefully prior to using the product. Failure to do so may result in electric shock, bodily injury, fire, product failure, or damage. Always use the supplied AC power cable if included. Using an AC power cable with inappropriate ratings may result in electric shock, bodily injury, fire, product failure, or damage. If an AC power cable is not included, please prepare a cable matching the specifications listed in section 9.2 "Specifications" of Instruction Manual. Using an AC power cable with inappropriate ratings may result in electric shock, bodily injury, fire, product failure, or damage. Prior to turning on the power, be sure to ground the product by connecting it to a grounded outlet. Insufficient grounding may result in electric shock, bodily injury, fire, product failure, or damage. Caution Operating precautions Avoid using the product near bodies of salt water or other locations susceptible to salt damage. Otherwise, it may result in product failure or damage caused by salt. Due to the internal power supply, certain sections of the product may experience an elevation in temperature that may cause a burn or bodily injury. Do not use the product outside its specifications. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. Do not use the product if it is defective, damaged, or burnt out. Otherwise, it may result in electric shock, bodily injury, or fire. When not using the product, turn off the power and unplug the AC power cable. Failure to do so may result in electric shock, bodily injury, fire, product failure, or damage. Transportation Excess stacking may cause the load to collapse so follow the directions written on the outside box. Failure to do so may result in bodily injury or damage. Handle the product with care during transportation, as it is dangerous if dropped. Failure to do so may result in bodily injury. The product is heavy so handle with care. Failure to do so may result in bodily injury. Handling Do not apply excessive stress or place heavy objects on the product. Otherwise, it may result in electric shock, bodily injury, product failure, or damage. Transport the product using the carrying handle. Failure to do so may result in bodily injury, product failure, or damage. Do not drop the product or subject it to excessive shock of any kind. Otherwise, it may result in product failure or damage. If the connection duct or tripod is attached to the main unit, make sure it does not tip over or drop while moving. Otherwise, it may result in bodily injury, product failure, or damage. Only use the product as specified in this instruction manual. Failure to do so may result in product failure or damage. Make sure that the intake and exhaust vents are free of debris and foreign matter. Otherwise, it may result in bodily injury, product failure, or damage. Mount the product on incombustible material below 60C. Failure to do so may result in fire, product failure, or damage. 528 Connecting the AC power cable Connect the AC power cable as instructed by the instruction manual. Failure to do so may result in electric shock, bodily injury, fire, product failure, or damage. Operation Operate the product within the specified input-power voltage to maintain stability. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. The auxiliary fan rotates during operation. Make sure that the intake and exhaust vents are free of debris and foreign matter. Keep hands away from the exhaust vent. Failure to do so may result in bodily injury, fire, product failure, or damage. Maintenance and inspection Some parts of the product (fan motor, gasket, electrolytic condenser, sensor, LED, switches) can deteriorate with long-term use. As preventive maintenance, perform periodic maintenance and inspection to maintain measuring accuracy. For details on maintenance, inspection, and repair, please contact SANYO DENKI. Disassembly is not to be performed by the end-user. Disassembly may result in electric shock, bodily injury, fire, malfunction, product failure, or damage. Prohibited Handling Do not scratch the connection duct with sharp objects as it may tear or damage the material. Operation Applying voltage outside the input voltage range may result in electric shock, bodily injury, fire, product failure, or damage. Never use voltages outside of specification. Keep the USB serial adapter away from static electricity and high voltage. Failure to do so may result in failure or damage. Do not use a polarized grounding adapter with the product. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. Storage Do not store the product where it could be exposed to rain, water, toxic gases, or other liquids. Failure to do so may result in product failure or damage. Maintenance and inspection Do not perform disassembly, inspection, or repairs. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. Do not measure the insulation resistance or the pressure resistance. Otherwise, it may result in product failure or damage. Never unplug the AC power cable while the power is on as the resulting surge voltage may damage electronic components. Otherwise, it may result in electric shock, bodily injury, or fire. Do not remove the nameplate attached to the product. Doing so voids the warranty. Do not wipe the product with benzene, paint thinner, or other solvents. Otherwise, it may result in deformation, deterioration, discoloration, product failure, or damage. Mandatory Operation In the case of any irregular operation, stop the device immediately. Otherwise, it may result in electric shock, bodily injury, fire, product failure, or damage. As a provisional measure, ensure that the power can be turned off at any time. Inability to turn off the power may result in electric shock, Temperature: 0C to 40C / Humidity 20 to 85% RH (non-condensing) Be sure to use the supplied AC power cable to prevent electric shock, bodily injury, fire, product failure, or damage. Be sure to prepare a cable matching the ratings listed in section 9.2 "Specifications" of Instruction Manual to prevent electric shock, bodily injury, fire, product failure, or damage. Prior to turning on the power, be sure to ground the product by connecting it to a grounded outlet to prevent electric shock, bodily injury, fire, product failure, or damage. Storage Store the product in a location that is not exposed to direct sunlight, at a temperature and humidity within specifications. Failure to do so may result in product failure. If the product has been stored for a long period, contact SANYO DENKI. There is the possibility that components may have deteriorated and require maintenance. Disposal When disposing of the product, treat it as industrial waste. 529 Airflow Tester bodily injury, fire, product failure, or damage. If an error occurs, eliminate the cause and ensure safety before resuming. Use the product within the specified temperature and humidity range. Failure to do so may result in product failure or damage. Options Cooling Fan Units Customized Products Features We provide assembled fan units in accordance with the specification or requirements of the equipment. For use in communications equipment, servers, storage systems. DC AC DC Features This cooling fan prevents electrolytic corrosion of bearings even under conditions where electromagnetic noise is generated. Electrolytic corrosion of ball bearings is prevented by using ceramic balls in ball bearings. The ceramic material is an insulating material. Manufacturable to meet specifications of all San Ace series fans. AC Example Electrolytic Corrosion Proof Fans 530 Customized Products p. 554 DC Finger guards List AC Increases safety by preventing foreign objects from entering fans. Fans can be used with little effect on airflow and static pressure. Size Model no. Mounting side Surface treatment 36 mm sq. type 38 mm sq. type 40 mm sq. type 109-1050 Inlet side, Outlet side - 109-1065 Inlet side, Outlet side - - - 109-059 109-059H 52 mm sq. type 109-149E Inlet side, Outlet side - 109-149 Outlet side - - - - - 109-139E 60 mm sq. type 109-139H 70 mm sq. type 80 mm sq. type 109-1128 109-049E - 109-099C Outlet side - 109-1147 Impeller side, Nameplate side - - - - - - - 109-099E 109-019K 109-019C 109-019H 127 175 mm type 127 mm sq. type o 133 mm type o 136 mm type 140 mm sq. type o 150 mm type Inlet side, Outlet side Outlet side Inlet side, Outlet side - 109-722H Inlet side, Outlet side - 109-723 Outlet side - 109-1112 Inlet side - 109-1139 Impeller side, Nameplate side - - - 109-719 Inlet side, Outlet side 109-1051 Inlet side, Outlet side - 109-1052 Outlet side - - - - 109-1104 109-1104H 160 mm sq. type Inlet side, Outlet side 109-722 109-719H 150 mm sq. type Inlet side, Outlet side - 109-019E mm sq. type, o Inlet side, Outlet side Outlet side 109-099H 120 mm sq. type Inlet side, Outlet side 109-049C 109-049H 92 mm sq. type o 92 mm type 92 mm sq. type, o100 mm type Inlet side, Outlet side 109-619E Inlet side Inlet side, Outlet side - 109-620 Outlet side - o 109-319J Inlet side, Outlet side - o 109-319E - - 109-619H 172 mm Sidecut type 172 mm Sidecut, Round type 109-319H o 172 mm Round type o 200 mm type 109-320 Outlet side - 109-1066 Inlet side, Outlet side - 109-1068 Outlet side - 109-1102 Inlet side, Outlet side - 109-1103 Outlet side - - - - - - - - - - 109-720 109-720H 109-721 109-721H o 221 mm type 109-1138 109-1138H o 225 mm type Inlet side, Outlet side 109-1137 109-1137H 270 mm sq. type 109-1146 (for Bracket-mounted Centrifugal Fan) Inlet side, Outlet side Outlet side Inlet side Inlet side Inlet side Option Nickel-chrome plating (silver) Cation electropainting (black) 531 Options Finger guards DC Dimensions (unit: mm) AC 36 mm sq. type 38 mm sq. type 40 mm sq. type Model no. Surface treatment Mass (g) 109-1050 Nickel-chrome plating (silver) 4 Model no. Surface treatment Mass (g) 109-1065 Nickel-chrome plating (silver) 5 Model no. Surface treatment Mass (g) 109-059 Nickel-chrome plating (silver) 7 109-059H Cation electropainting (black) Inlet side, Outlet side Inlet side, Outlet side Inlet side, Outlet side 4-o40.3 4.80.5 3.50.3 6 o1.6 .5 o29 o2 8. 5 o1 8. 3 5.3 o4 5 0. .5 7.5 0 o1 o1.6 30 .5 5 29 o1 6 .6 49 +1.5 -0.5 32 29 o2 o1.6 o1 o1. 34 6 o1. +1 0 4 38.5 30 .5 0 0. 5 .5 +1 +0.3 0 4.8 0 4-o4 52 mm sq. type 60 mm sq. type Model no. Surface treatment Mass (g) 109-149E Nickel-chrome plating (silver) 9 Model no. Surface treatment Mass (g) 109-149 Nickel-chrome plating (silver) 7 Model no. Surface treatment Mass (g) 109-139E Nickel-chrome plating (silver) 14.5 109-139H Cation electropainting (black) Inlet side, Outlet side Outlet side Inlet side, Outlet side o1.6 o53 6 o1. .8 +1.5 63.2 -0.5 53.3 63.2 +1.5 -0.5 o43 +1 0 6 o32. o5 4 +1 0 o70.7 9.4 o59.4 4.30.3 o1.6 o1.6 +1.5 o43.8 .6 4 53.3 o1.6 o1 3.70.3 75 -0.5 3.70.3 62 4 +10 70 mm sq. type 80 mm sq. type Model no. Surface treatment Mass (g) 109-1128 Nickel-chrome plating (silver) 17 Model no. Surface treatment Mass (g) 109-049E Nickel-chrome plating (silver) 21 109-049H Cation electropainting (black) Model no. Surface treatment Mass (g) 109-049C Nickel-chrome plating (silver) 17 Inlet side, Outlet side Inlet side, Outlet side Outlet side 4.30.3 o75 5 4.30.3 5 +10 o1.6 o75 88 +1.5 105 -0.5 88 78 +1.5 o1.6 91 -0.5 3.2 105 +1.5 -0.5 o6 4.30.3 o1.6 o1.6 5 +10 o1.6 16 o1.6 o +1 0 o3 9.6 (o8 o101.2 7) o101.2 92 mm sq. type o92 Model no. Surface treatment Mass (g) 109-099C Nickel-chrome plating (silver) 22 Model no. Surface treatment Mass (g) 109-1147 Nickel-chrome plating (silver) 23 Model no. Surface treatment Mass (g) 109-099E Nickel-chrome plating (silver) 29 109-099H Cation electropainting (black) Outlet side Impeller side, Nameplate side Inlet side, Outlet side 5) 7.6 o7 o1.6 8. 99 +1.5 120.5 -0.5 o1 6. 6 +1 4 0 .6 16 o1.6 75 3.50.5 o1 o87 88.80.5 3.50.3 o1.6 5 4.30.3 o1.6 o1.6 ( o8 3.50.5 o1 6.6 o11 532 5 99 120.5 +1.5 -0.5 4.30.3 o1.6 o1.6 9.8 o3o87 +1 0 92 mm sq., o100 mm type mm type 2 +1 0 Finger guards DC Dimensions (unit: mm) AC 127 mm sq., o175 mm type 120 mm sq. type Model no. Surface treatment Mass (g) 109-019E Nickel-chrome plating (silver) 42 109-019K Cation electropainting (black) Model no. Surface treatment Mass (g) 109-019C Nickel-chrome plating (silver) 32 109-019H Cation electropainting (black) Model no. Surface treatment Mass (g) 109-722 Nickel-chrome plating (silver) 43 109-722H Cation electropainting (black) Inlet side, Outlet side Outlet side Inlet side, Outlet side 19 142 130 4.30.3 o24.6 o1 13 o1 .2 o1.6 +0.4 4.3 -0.2 o42 130 4.30.3 o18.6 152.50.5 o1.6 o1.6 o1.6 1650.5 3 11 o 5 +10 o148 o1.6 o1.6 5 +10 o160.5 o14 5 -10 8 152.5 +1.5 -0.5 127 mm sq. type o133 o136 Model no. Surface treatment Mass (g) 109-723 Nickel-chrome plating (silver) 34 Model no. Surface treatment Mass (g) 109-1112 Nickel-chrome plating (silver) 65 Model no. Surface treatment Mass (g) 109-1139 Nickel-chrome plating (silver) 41 Outlet side Inlet side Impeller side, Nameplate side mm type 4.30.3 o1.6 .4 08 o1 120 1332 o87 123.11 1650.5 4.30.2 19 o1 ) (o60 o1.6 3.21 o1.6 o1.6 o16 o1.6 o1.6 3.50.3 o118 3.2 -10 mm type o1 o160.5 28) (o1 6 5 +1 0 140 mm sq. type 150 mm sq. type Model no. Surface treatment Mass (g) 109-719 Nickel-chrome plating (silver) 51 109-719H Cation electropainting (black) Model no. Surface treatment Mass (g) 109-1051 Nickel-chrome plating (silver) 63 Model no. Surface treatment Mass (g) 109-1052 Nickel-chrome plating (silver) 53 Inlet side, Outlet side Inlet side, Outlet side Outlet side +0.4 -0.2 0 5.5 -1 4.30.2 4-12 o156 4-4.5 (o6 2.2 o1 6.8 ) .8 43 o1.6 .8 o1.6 mm type o1.6 43 o1 .2 36 o1.6 o150 o2 o1 26.8 o 4-4.5 o145 4-12 o1.6 0 3.2 -1 Option 4.3 197.70.5 o1.6 +0 -1 5.5 -10 o190.9 o190.9 .5 +0.4 -0.2 o201 + 6 -1 o1706.5 o18 4.3 160 mm sq. type Model no. Surface treatment Mass (g) 109-1104 Nickel-chrome plating (silver) 31 109-1104H Cation electropainting (black) Model no. Surface treatment Mass (g) 109-619E Nickel-chrome plating (silver) 85 109-619H Cation electropainting (black) Model no. Surface treatment Mass (g) 109-620 Nickel-chrome plating (silver) 74 Inlet side Inlet side, Outlet side Outlet side o1.8 +0.4 5.5 -0.2 0 3.6 -1.5 o1.8 o1.8 o184 o111.5 8 -1.5 5.9 7 3 0 +0.4 -0.2 5 +01. - 6. o1.8 5.5 5.2 o2 .9 o o20 5 +01. - +0.4 4.3 -0.2 9 o1 59. o1 5.2 95 7 o1 59. o1 .6 97 o20 o1.6 o128.7 +2 o136.2 -1 0 5.5 -1 7 1. o6 o1.6 533 Options Finger guards o172 DC Dimensions (unit: mm) AC mm Sidecut type Model no. Surface treatment Mass (g) 109-319J Nickel-chrome plating (silver) 65 Applicable model no. 9SG57P5/9GV57H501 9CR5748P9G001/9WG5748P5001 Finger guard 109-319J should be mounted with four holes as in the drawing. Hexagonal nuts Inlet side, Outlet side +0.4 4.3 -0.2 o1.6 Plain washers Spring washers 0 5.5 -1 Screws o152 o162 o172 +0.5 -1 o1.6 o147 Finger guards Fan 55 .5 71.31 71.31 No nuts or screws for use in attachment included. o172 mm Sidecut, Round type Model no. Surface treatment Mass (g) 109-319E Nickel-chrome plating (silver) 69 109-319H Cation electropainting (black) Model no. Surface treatment Mass (g) 109-320 Nickel-chrome plating (silver) 53 Inlet side, Outlet side Outlet side 5 +0. 2 -1 o17 o162 o1.6 o1 +0.4 4.3 +0.4 -0.2 o1.6 o1.6 o62.2 0 4.3 -0.2 o1.6 9.5 -1 48 Finger guards 109-319E, 109-319H, and 109-320 should be mounted with two holes as in the drawing and do not use any other holes. Hexagonal nuts 0 3.2 -1 Finger guards Plain washers Spring washers o152 Screws o148 o172 +0.5 -1 o162 Fan No nuts or screws for use in attachment included. o172 mm Round type Model no. Surface treatment Mass (g) 109-1066 Nickel-chrome plating (silver) 61 Model no. Surface treatment Mass (g) 109-1068 Nickel-chrome plating (silver) 54 Inlet side, Outlet side Outlet side o162 -1 o172 +0.5 o1.6 +0.4 4.3 -0.2 o1.6 0 9.5 -1 o152 o148 534 o162 -1 o172 +0.5 o1.6 o148 +0.4 4.3 -0.2 o1.6 o62.2 0 3.2 -1 Finger guards AC mm type Model no. Surface treatment Mass (g) 109-1102 Nickel-chrome plating (silver) 100 Applicable model no. 9GV2048P0G201 Model no. Surface treatment Mass (g) 109-1103 Nickel-chrome plating (silver) 80 Inlet side, Outlet side Outlet side +0 +0 -1 0 -1 89 214.1 -0.5 (196.3) B o1.6 +0.4 o1.6 +0 4.3 -0.2 3.2 -1 .8 o +1 .2) (o92 +1 o1.6 0 20 8 9.5 o1 9.5 -1 A 8 o20 .8 82 o1 9 19 4.3 -0.2 o1.6 o20 +0.4 +1 -0.5 Applicable model no. 9GV2048P0G201 214.1 -0.5 o200 DC Dimensions (unit: mm) B A o200 AAAA Section BB BB Section mm type Model no. Surface treatment Mass (g) 109-720 Nickel-chrome plating (silver) 84 109-720H Cation electropainting (black) Applicable model no. 109E2024 9EC20001 Model no. Surface treatment Mass (g) 109-721 Nickel-chrome plating (silver) 66 109-721H Cation electropainting (black) Inlet side, Outlet side Outlet side o18 78 o1 0 8 -1 8.4 8.4 o18 1 7 o1 4.3 +0.4 -0.2 o1.6 +1 -0.5 Inlet side Inlet side A o194.1 217.61 210.61.5 0 5.5-1 86 .9 B +1 250.8 - 0.5 A o1.6 o1 .4 1 19 4 5. 20 4.30.3 o26.8 B o1.6 .2 o192 o1.6 80 o1.6 o1.6 o213.3 +0.4 4.3 - 0.2 o1.6 o1 o245 9 1. 5 Model no. Surface treatment Mass (g) 109-1137 Nickel-chrome plating (silver) 94 109-1137H Cation electropainting (black) Option mm type Model no. Surface treatment Mass (g) 109-1138 Nickel-chrome plating (silver) 105 109-1138H Cation electropainting (black) 6.8 3.2 -10 194.5 o178 +1 194.5 -0.5 o225 mm type o2 4.3 +0.4 -0.2 o1.6 o1.6 o1.6 o221 Applicable model no. 109E2024 9EC20001 50.5 Section AAAA -1 3.2 +0 BBBB Section 535 Options Finger guards DC Dimensions (unit: mm) 270 mm sq. type (for Bracket-mounted Centrifugal Fan) Finger guard 109-1146 should be mounted with four holes as in the drawing. Model no. Surface treatment Mass (g) 109-1146 Nickel-chrome plating (silver) 106 Inlet side 5.30.3 Finger guard o2 A Screws .9 86 o1 19 4 .4 1 .7 .2 80 o305 o1 B o1.6 o1.6 o26 3111 o194.1 .8 +0.5 3.6 -1 B +0 3.2 -1 Section BB BB A Fan 51 No nuts or screws for use in attachment included. Section AA AA Mounting example Axial fan Centrifugal fan Hexagonal nuts Fan Finger guard Hexagonal nuts Plain washers Inlet nozzle Spring washers Finger guard Screws Plain washers Fan Chassis No nuts or screws for use in attachment included. 536 Spring washers Screws AC Inlet nozzle for centrifugal fan and splash proof centrifugal fan DC Dimensions (unit: mm) Nozzle mounted in fan inlet side to adjust the flow of introduced air. Material: Steel sheet o133 mm type Model no. 109-1080 Surface treatment Electro nickel plating (silver) Model no. 109-1069 109-1069H Surface treatment Electro nickel plating (silver) Cation electropainting (black) 131 (1) 1 Ea 4- ch ) 4.8 o4 (R .5 0 .5 .5 0 h 4.3 c Ea 4-o 1 o150 o175 mm type Model no. 109-1081 109-1081H Surface treatment Electro nickel plating (silver) Cation electropainting (black) Mass (g) 70 Surface treatment Electro nickel plating (silver) Cation electropainting (black) 45 o225 Mass (g) 230 5.2 o15 1181 29.51 (1.5) 1 Mass (g) 360 ) ch Ea ( 0.5 o242 211 (0.8) Surface treatment Electro nickel plating (silver) Cation electropainting (black) 90 0.5 5 o24 0.5 4.3 4-o Model no. 109-1134 109-1134H 0.5 6 1 6 0 (E 1 ac h) 1 ) O .5 22 (R 4-4 901 (Each) 45 .5 mm type o14 0 0. 5 Surface treatment Electro nickel plating (silver) Cation electropainting (black) o2100.5 1 o223 5.5 0) (R1 5 0. .5 o4 0. h .5 c Ea -o4 4 1 h c Ea 1 52 o2 6-o 100 0.5 6 141 (1) 90 O 6) (R mm type Model no. 109-1135 109-1135H Mass (g) o12 o1580.5 1 o170 90 0.5 .5 71 (1) mm type Model no. 109-1073 109-1073H o100 o1280 1 9 o13 o221 76 0.5 .5 0.5 90 Mass (g) o85 o1180 1 9 o12 o70 90 0.5 o116.6 1 8 o12 51 (1) Mass (g) 80 mm type Option o100 ) 0.5 24 (R 537 Options EMC guards DC Dimensions (unit: mm) It is a metallic piece that protects materials from the adverse effects of electromagnetic noise sources. It provides electromagnetic shielding. It is attached to the casing of a device by means of the fan fixing screw (s). Ground the devices equipped with an EMC guard. 80 mm sq. type 80 mm sq. type 92 mm sq. type Model no. Surface treatment Mass (g) 109-1038 Nickel-chrome plating (silver) 14 Model no. Surface treatment Mass (g) 109-1039 Nickel-chrome plating (silver) 10 Model no. Surface treatment Mass (g) 109-1040 Nickel-chrome plating (silver) 15 Representative fans model numbers Dimensions of fans (mm) Representative fans model numbers Dimensions of fans (mm) Representative fans model numbers Dimensions of fans (mm) 109P08* 9GV08* 9GV08* 9HV08* 9HVA08* 80 x 80 x 20 80 x 80 x 25 109P08* 9GA08* 109R08* 9A08* 9GA08* 80 x 80 x 15 80 x 80 x 20 9G09* 9G09* 9GV09* 9GA09* 92 x 92 x 32 9GA08* 80 x 80 x 32 9G08* 9GA08* 80 x 80 x 38 5 +1 0 4.3 0.3 o1.6 3 1 +1.5 +1.5 88 6.6 Model no. Surface treatment Mass (g) 109-1037 Nickel-chrome plating (silver) 26 Model no. Surface treatment Mass (g) 109-1036 Nickel-chrome plating (silver) 49 9G12* 9GV12* 9GL12* 9G12* 9GV12* 9HV12* 9LG12* 120 x 120 x 25 120 x 120 x 38 5 +1 0 o 172 x 25 +0.5 o172-1 o 172 x 51 +0 9.5-1 +0.4 4.3- 0.2 o1.6 o14 8 EMC guard 538 attached to a cooling fan o152 o7 7.2 o5 130 152.5 0.5 2 o1.6 Dimensions of fans (mm) 109E47* 109L17* 9GV57* 109E17* 109E57* 9SG57* o162 4.3 0.3 mm type Representative fans model numbers +1 0 o43 o11 .2 1.2 o101 o10 o172 Dimensions of fans (mm) 5 o1.6 120 mm sq. type Representative fans model numbers 92 x 92 x 38 4.3 0.3 o3 105- 0.5 88 +1.5 +1 0 o1.6 o4 105- 0.5 5 120.5- 0.5 4.3 0.3 80 x 80 x 25 99 80 x 80 x 38 Resin finger guards DC Dimensions (unit: mm) AC Material Frame: Resin (PPE+PS) UL file no. E82268 94V-0 60 mm sq. type 80 mm sq. type Mass (g) 7 6.50.5 4-20.5 821 92 mm sq. type 70.5 4-20.5 4-o4.30.3 120 mm sq. type Model no. 109-1001G Mass (g) 12 921 82.50.3 Mass (g) 23 1191 104.80.3 4-o4.30.3 70.5 4-o4.30.3 4-2 0.5 1191 104.80.3 70.5 4-20.5 Model no. 109-1000G 82.50.3 921 Mass (g) 10 821 71.50.3 4-o4.30.3 500.3 60.51 60.51 500.3 Model no. 109-1002G 71.50.3 Model no. 109-1003G Airflow - Static pressure characteristics Mounting example Measured with our double chamber measuring device (120 mm sq. type) (Pa) 160 Fan unit (9G1212G101) Static pressure 140 120 Hexagonal nuts (4) 100 80 * With resin finger guard 60 (109-1000G) equipped Fan 40 0 1 2 3 Airflow 4 5 (m3/min) Applied voltage: 12 VDC * Finger guard is attached on air inlet side of fan. Option 20 Chassis Finger guard Small pan-head screws (4) Operating temperature limit is between -20 to +70C. (non condensing) Plastic finger guards are placed on both the intake and exhaust sides of the fan. No nuts or screws for use in attachment included. 539 Options Resin filter kits DC Dimensions (unit: mm) AC Material Guard, cover: Resin (PPE+PS) UL file no. E82268 94V-0 Filter: Polyurethane foam UL file no. E74916 (S) 94HF-1 PPI: Particles Per Inch Indicates the number of holes per inch. Note that the higher the number, the finer the grain of the sponge. 60 mm sq. type 80 mm sq. type Model no. 109-1003F13 (13 PPI) 109-1003F20 (20 PPI) 109-1003F30 (30 PPI) 109-1003F40 (40 PPI) Mass (g) Replacement filter model no. 109-1003M13 (13 PPI) 109-1003M20 (20 PPI) 109-1003M30 (30 PPI) 109-1003M40 (40 PPI) Quantity Replacement filter model no. 109-1002M13 (13 PPI) 109-1002M20 (20 PPI) 109-1002M30 (30 PPI) 109-1002M40 (40 PPI) Quantity 5 85.51 71.50.3 4-o4.30.3 85.51 4-o100.5 4-o100.5 4-20.5 92 mm sq. type 5 10.50.5 4-o4.30.3 4-20.5 120 mm sq. type Model no. 109-1001F13 (13 PPI) 109-1001F20 (20 PPI) 109-1001F30 (30 PPI) 109-1001F40 (40 PPI) Mass (g) Replacement filter model no. 109-1001M13 (13 PPI) 109-1001M20 (20 PPI) 109-1001M30 (30 PPI) 109-1001M40 (40 PPI) Quantity Model no. 109-1000F13 (13 PPI) 109-1000F20 (20 PPI) 109-1000F30 (30 PPI) 109-1000F40 (40 PPI) Mass (g) Replacement filter model no. 109-1000M13 (13 PPI) 109-1000M20 (20 PPI) 109-1000M30 (30 PPI) 109-1000M40 (40 PPI) Quantity 25 10.50.5 1241 104.80.3 4-o4.30.3 1241 82.50.3 4-o9.50.5 4-o110.5 4-20.5 Airflow - Static pressure characteristics 44 5 10.50.5 4-o4.30.3 104.80.3 96.51 5 82.50.3 Mounting example 4-20.5 Filter replacement (example) Measured with our double chamber measuring device (120 mm sq. type) (Pa) 160 Hexagonal nuts (4) Replacement filters can be replaced by taking off the front part of the filter kit. There is no need to remove the screws. Fan unit (9G1212G101) 140 Static pressure 19 71.50.3 9.50.5 500.3 641 Mass (g) 11 641 500.3 96.51 Model no. 109-1002F13 (13 PPI) 109-1002F20 (20 PPI) 109-1002F30 (30 PPI) 109-1002F40 (40 PPI) 120 * With filter kit (109-1000F20) equipped 100 * With filter kit (109-1000F40) equipped 80 60 Fan 40 20 0 Chassis 1 2 3 Airflow 4 5 (m3/min) Applied voltage: 12 VDC * Filter kit is attached on air inlet side of fan. Filter kits Small pan-head screws (4) Replacement filters Filter kit is one of the option to keep air in the chassis clean filtering dust in external atmosphere when pulling-air cooling is implemented. The filter kit is hooked up through mounting hole of fan frame with screw as well as finger guard. Some performances (airflow & static pressure) of the fan motor decreases when filter kit is hooked up. This Filter Kit is composed of 3 components, including a guard, a filter and a cover. It is delivered as a finished product at delivery, saving assembly time when mounting. It can be mounted by inserting a screw in the apertures of the cover. The filter and cover can be easily removed from the guard with one touch. There is no need for fan removal when undertaking maintenance. Operating temperature limit is between -10 to +60C. (non condensing) The filter will deteriorate with age, and the level of deterioration will vary upon usage conditions. Please be aware that the filter has a greater tendency to deteriorate under high temperature and humidity. For long-term storage, please store under the temperature range of 10 to 30C, humidity range of 20 to 65%. Usage and storage period is approximately 2 years. Cooling ability decreases with filter contamination due to clogging. Filter replacement is recommended approximately every six months of usage. Please replace the filter if deterioration or clogging is seen at inspection. When replacing the filter, please use genuine SANYO DENKI filters. Do not water-wash the filter. Avoid use and storage under high temperature or humidity, direct sunlight or exposure to ultraviolet light, or in corrosive gas. No nuts or screws for use in attachment included. 540 Filter kits Applicable models: AC Fan 120 x 120 x 38 mm Dimensions, Reference Dimensions of Mounting Holes (unit: mm) Neither filter kit can be installed on ACDC fans, or AC fans with sensors. Please evaluate it by assembly filter kits on the derice. Model no. 109-018 Material Steel Wire Mesh: Stainless 16-mesh nets in 3 layers Cover: Resin Metal fittings: Steel (chromate-plated) AC Mass (g) 182 Airflow - Static Pressure Characteristics Dimensions (Measured with our double chamber measuring device) (64) (Pa) 80 8.5 109S005 109S005+109-018 Filter kits 1310.8 Static pressure 70 60 50 60 Hz 40 50 Hz 30 20 10 0 1 155.60.8 2 3 (m3/min) Airflow Reference Dimensions of Mounting Holes Mounting Example Mounting plate Spncer Round head screw Hexagon nut Spring washer Washer 127 89 4-4 4-omm 4 dia holes Fan Installation brackets (2 pcs) 131 140.5 The parts shown in the installation diagram (nuts, washers, and screws) are included. Holes for cabinet installation Filter Cover (resin) Screen kits Applicable models: AC Fan 120 x 120 x 38 mm Dimensions, Reference Dimensions of Mounting Holes (unit: mm) Neither screen kit can be installed on ACDC fans, or AC fans with sensors. 109-020 Material Steel Wire Mesh: Stainless 16-mesh nets in 1 layers Cover: Resin Metal fittings: Steel (chromate-plated) Mass (g) 135 Airflow - Static Pressure Characteristics Dimensions 140.50.8 8.5 (Measured with our double chamber measuring device) (Pa) 80 109S005 109S005+109-020 Screen kits 1310.8 890.6 Static pressure 70 155.60.8 60 50 Option Model no. AC 60 Hz 40 50 Hz 30 20 10 0 1 2 3 (m3/min) Airflow Reference Dimensions of Mounting Holes Mounting Example Round head screw Mounting Plate Washer Spring washer Hexagon nut Screen Kit 127 89 4-4 4-omm 4 dia holes 131 140.5 The parts shown in the installation diagram (nuts, washers, and screws) are included. Fan Installation brackets (2 pcs) Holes for cabinet installation 541 Options Plug cord for AC fan AC Dimensions (unit: mm) Products compliant with electrical appliance and material safety law For 80 x 80 x 25 mm, 80 x 80 x 38 mm, 92 x 92 x 25 mm, 120 x 120 x 25 mm For 80 x 80 x 42 mm Power cord length [L] (mm) 1000 2100 3500 Flat 2-core vinyl cord VFF0.75 mm2 Black Mass (g) 30 61 99 Model no. 489-016-L10 489-016-L21 20 7.5 5.6 10 Pre-soldered 9.5 11.5 ORIEX 10 5 ORIEX 11 50 Mass (g) 34 64 3A 250V E JET 3A 250V 1.5 Pre-soldered E JET 16.5 Power cord length [L] (mm) 1000 2100 Flat 2-core vinyl cord VFF0.75 mm2 Black 17.5 Model no. 489-008-L10 489-008-L21 489-008-L35 L 50 10 18 4 L 6 24 8 10 8.9 20 6 25 For 120 x 120 x 38 mm (not including AC/DC fan) Model no. 489-006-L10 489-006-L21 489-006-L35 Power cord length [L] (mm) 1000 2100 3500 For 120 x 120 x 38 mm (not including AC/DC fan) Mass (g) 47 76 114 (Exclusive for fans without UL at the end of the model number.) Model no. 489-037-L10 489-037-L21 489-037-L35 Power cord length [L] (mm) 1000 2100 3500 (Exclusive for fans with UL at the end of the model number.) VSF1.25 mm2 For ground, Black VSF1.25 mm2 For ground, Black 7.9 24 50 10 4 R1 G G IN 26.9 19.5 5 8 IN Pre-soldered +20 0 60 0 E JET ORIEX 3A 250V E JET ORIEX 3A 250V G +20 0 60 0 5 8 21.2 24.7 26.9 7.9 L 24 50 4 L Power cord length [L] (mm) 1000 2100 Mass (g) 34 64 9.5 19 Flat 2-core vinyl cord VFF0.75 mm2 Black 19.5 18 4 16.5 40.5 18.5 Pre-soldered 5.5 17.5 8 .3 R0 20 10 Model no. 489-1619-L10 489-1619-L21 3A 250V ORIEX 3A 250V PSE JET 9 11 50 Mass (g) 34 63 83 For o 172 x 51 mm, o 172 x 150 x 51 mm, 160 x 160 x 51 mm PSE JET ORIEX S272 L 10 Flat 2-core vinyl cord 2 VFF0.75 mm Black For 160 x 160 x 51 mm Power cord length [L] (mm) 1000 2100 2800 Pre-soldered G Flat 2-core vinyl cord 2 VFF0.75 mm Black Model no. 489-1618-L10 489-1618-L21 489-1618-L28 Mass (g) 46 76 114 9 13.5 16.5 30 50 10 Pre-soldered 17.5 8 L Flat 2-core vinyl cord 2 VFF0.75 mm Black Be careful not to damage the plug/cord when taking them out of the package. 542 Plug cord for AC fan AC Dimensions (unit: mm) UL/CSA certified UL file no.: E50197 CSA file no.: LR67048 For 120 x 120 x 38 mm (not including AC/DC fan) Model no. 489-007-L10 489-007-L21 Power cord length [L] (mm) 1000 2100 Mass (g) 48 80 For 80 x 80 x 25 mm, 80 x 80 x 38 mm, 92 x 92 x 25 mm, 120 x 120 x 25 mm Model no. 489-047-L10 489-047-L21 (Exclusive for fans with UL at the end of the model number.) Power cord length [L] (mm) 1000 2100 Flat 2-core vinyl cord UL SPT-1 AWG18 Black Pre-soldered 4 10 50 18 24 .5 R1 R1 6 8 Flat 2-core vinyl cord UL SPT-1 AWG18 Black 10 L L 7.9 20 17.5 7.5 4 24 50 26.9 8 R1 9.5 11 8.9 24.7 8.2 600 Pre-soldered 11.5 UL 1015 AWG18 For ground, green/yellow spiral +20 0 Mass (g) 38 71 For o 172 x 51 mm, o 172 x 150 x 51 mm, 160 x 160 x 51 mm Model no. 489-084-L10 489-084-L21 For 160 x 160 x 51mm Power cord length [L] (mm) 1000 2100 Model no. 489-086-L10 489-086-L21 Mass (g) 37 70 Power cord length [L] (mm) 1000 2100 Mass (g) 37 70 8 17.5 15.5 50 9 13.5 ORIEX 3A 250V 16.5 L Pre-soldered 16.5 L 50 9 11 10 16.5 4 Flat 2-core vinyl cord UL SPT-1 AWG 18 Black 16.5 37 5.5 30 10 8 Pre-soldered Flat 2-core vinyl cord UL SPT-1 AWG 18 Black Plug cord for ACDC fan AC Dimensions (unit: mm) Model no. 489-1635-L10 489-1635-L21 Power cord length [L] (mm) 1000 2100 Mass (g) 38 74 Model no. 489-1636 Option Products compliant with electrical appliance and material safety law, UL/CSA [c-UL] certified UL file no.E43202 Wiring Harness for Sensor Mass (g) 9 100020 10 8 101 Pre-soldered L 8 15.5 Pre-soldered 4 10 20 4 17 50 10 2 5 Flat vinyl cord 2-core 2 SPT-1 SPT-1&&HVFF HVFF 2 2(AWG18) 0.75 mm 0.75 mm (AWG18) Black Be careful not to damage the plug/cord when taking them out of the package. 543 Options Recommended connectors for DC fans Manufacturer MOLEX Tyco Electronics Hirose Japan Solderless Terminals DC 2 pins Housing model number 3 pins Housing model number 4 pins Housing model number Contact model number 08700064:P/N 5159T 08700048:P/N 5159PBT 39000372:P/N 2759T 430300001 430300002 430300003 508029001 08701039:P/N 5263PBT 39000059:P/N 5556PBT 39000038:P/N 5556T 1702621 1792271 DF1B2428PCF 22011022:P/N 505102 22011032:P/N 505103 22013037:P/N 269503RP 22011042:P/N 505104 430250200 430250400 511910200 50375023:P/N 526402 511910300 50375033:P/N 526403 511910400 50375043:P/N 526404 39012020:P/N 555702R 39012040:P/N 555704R 1718222 1792282 DF1B2EP2.5RC DF32EP2C DF3AA2EP2C EHR2 SMP02VBC SMP02VNC H2PSHFAA PHR2 XAP02V1 XMP02V 1718223 1792283 DF1B3EP2.5RC DF33EP2C DF3AA3EP2C EHR3 SMP03VBC SMP03VNC H3PSHFAA PHR3 XAP03V1 XMP03V 1718224 1792284 XHP2 XHP3 XHP4 SXH001GUP0.6 SXH001TP0.6 SMR02VB SMR02VN SMR03VB SMR03VN SMR04VB SMR04VN SYM001TP0.6 DF34EP2C DF3AA4EP2C EHR4 SMP04VBC DF3EP2428PCF SEH001TP0.6 SHF001T0.8BS PHR4 XAP04V1 SPH002TP0.5S SXA001TP0.6 Recommended tubes and cable ties for DC fan Manufacturer PVC tube Thermal contraction tube Cable tie YAMAICHI CHEMICAL IWASE KAGAKU KOGYO SUMITOMO ELECTRIC SUMI-PAC THOMAS & BETTS PANDUIT HellermannTyton DC Representative model numbers YET-300H AH-3 SUMITUBE(R) F2 (Z) SUMITUBE(R) F32 TY-23M BT1M T18R Specifications UL file no. 105C 300 V VW-1 E55011 E56036 125C 600 V VW-1 E48762 UL 94V-2 E49405 E56854 E64962 Note : The specifications in this table are for reference purposes only. When selecting, please check catalogs of each brand. 544 Technical Material Overview and Characteristics of Fan Overview DC AC A cooling fan is widely used to extend life of your system by cooling off heat of the system that many electrical components are mounted in a very high density and dissipating heat. Since we SANYO DENKI developed "San Ace" which is the first AC fan in Japan in 1965, we have increased fan motor lineup until now meeting customers needs rapidly based on our tremendous career. We SANYO DENKI will continue to develop new fans with high airflow, low noise, low vibration, and energy - saving design. Characteristics DC AC We can roughly devide fan into two types which are AC and DC. AC fans SANYO DENKI succeeded in the mass-production of AC fans in 1965. SANYO DENKI was the first Japanese manufacturer to have succeeded at this. High performance High reliability Safety DC fans SANYO DENKI succeeded in the mass-production of DC fans in 1982. High performance Low power consumption Low vibration Low leakage of flux High reliability SANYO DENKI currently has a wider variety of products like Long Life Fan, CPU cooler, Splash Proof Fan, and Oil Proof Fan etc to meet all customer needs. Reliability and expected life AC 1000000 Expected life 180000 h (L10, 60C) Expected life 80000 h (L10, 60C) Expected life 150000 h (L10, 60C) Expected life 60000 h (L10, 60C) Expected life 100000 h (L10, 60C) Expected life 40000 h (L10, 85C) Expected life (h) 100000 Expected life 40000 h (L10, 60C) Expected life 30000 h (L10, 60C) 10000 1000 20 40 60 80 100 Ambient temperature (C) Rated voltage, continuously run in a free air state, survival rate of 90% Expected life of AC fans Technical Material 100000 Expected life 60000 h (L10, 60C) (ACDC fans) 50000 Expected life (h) A cooling fan generally cools itself as well. The temperature rise of the motor is relatively low and the temperature rise of the grease in the bearings is also low, so expected life is longer than general some either motors. S i n c e t h e s e r v i c e l i fe o f b e a r i n g s i s a theoretical value that applies when they are ideally lubricated, the life of lubricant can be regarded as expected life of the fan. DC fan consumes less power and its temperature rise of bearing is very low. When the measurement conditions are: L10 (the remaining product life in the lifespan test is 90%),with an atmospheric temperature of 60 degrees, at the rated voltage, and continuously run in a free air state. The table below indicates the relationship between ambient temperature and expected life estimated on the basis of our life tests and same other tests conducted by SANYO DENKI. DC Expected life of DC fans Expected life 25000 h (L10, 60C) 20000 10000 20 40 60 80 100 Ambient temperature (C) Rated voltage, continuously run in a free air state, survival rate of 90% 545 Technical Material Noise characteristics Noise is average value that measured at l meter away from air intake side of fan that is suspended on special frame in anechoic chamber (as per JIS B 8346). DC AC DC AC Fan Noise meter AIRFLOW Acoustic radio wave anechoic chamber 1m Noise characteristic measurement equipment Measuring airflow and static pressure It is very difficult to measure airflow and static pressure. In fact, the performance curve may vary greatly according to the type of measuring equiment. The commonly-used type of measuring equipment is a wind tunnel using a Pitot tube. SANYO DENKI uses a very precise method using double chamber equipped with many nozzles. U-shaped tube Throttle device Pn Ps Chamber B U-shaped tube Q 60A v (A) where Q = airflow (m3/min) Specific weight of air = g (N/m3) (Air density = 1.2 kg/m3 at 20C, 1 atm) g = acceleration of gravity = 9.8 (m/s2) Pn= differential pressure (Pa) Ps = static pressure (Pa) Chamber A Nozzle BM Auxiliary blower Fan to be measured Double chamber measuring equipment The measuring equipment using double chanber is method to be calculated from airflow goes through nozzle and differential pressure between pressure of inside of chamber (Ps) and atomospheric pressure by measuring differetial pressure between air intake and exhaust of nozzle (Pn). Conversion table Static pressure 1 mm H2O0.0394 inch H2O 1 mm H2O9.8 Pa (Pascal) 1 inch H2O25.4 mm H2O 1 Pa0.102 mm H2O 1 inch H2O249 Pa 546 D2 (m2) A = cross sectional area of nozzle- 4 D = nozzle diameter (m/s) v = average airflow velocity of nozzle 2g Pn DC Airflow 1 m3/min35.31 ft 3/min (CFM) 1 CFM0.0283 m3/min 1 m3/min16.67 /s 1 CFM0.472 /s 1 /s0.06 m3/min AC Motor Protection If the fan blades are restricted, an overcurrent occurs and leads to a rise in the fan coil temperature. This can result in reduced performance, damage, or a fire. To prevent this from occurring, SANYO DENKI's fans incorporate an overheating protection function. Reverse polarity protection function (DC fan) No problem about fan even if positive & negative lead are connected in reverse. However, when wiring fans with sensors or PWM speed control function, connecting positive and negative leads in reverse may damage the fans. Burnout protection function at locked rotor condition (DC fan, ACDC fan) Current cutoff system If the fan blades are restricted, the coil current is cut off at regular cycles to prevent overheating of the coil. When the hindrance is removed, the fan restarts automatically. Burnout protection function at locked rotor condition (AC fan) Impedance protection (60 mm sq., 80 mm sq., 92 mm sq., 120 mm sq.) This system is used for shading coil-type fans. When the blades are restricted, the current is reduced by the impedance of the coil itself to prevent a temperature rise in the coil. However, if the applied voltage exceeds the specification range, an overcurrent can occur and result in overheating, and so care needs to be taken. Technical Material Thermal protection (160 mm sq., o172 mm) This system is used for condenser phase-type fans. A temperature sensor is incorporated in the coil so that if the temperature exceeds the specification temperature, the current is cut off to prevent overheating of the coil. 547 Technical Material Guideline in Selecting a Fan How to select an appropriate fan DC AC The following example is a guideline regarding how to select an appropriate fan for cooling your system System 1. Determining of your system specifications and conditions Determine the temperature rise inside your system and obtain the total heating value inside your system on the basis of its inputs and outputs. Example V: Total heating value of your system (W)=100 (W) T: Inside temperature rise (K)=15 (K) Fan T Q' V Heat source 2. Calculating the required airflow for cooling After the equipment specifications and conditions of your system have been determined, calculate required airflow to meet the conditions. (Note that the formula shown below only applies when the heat radiation is performed only by cooling air from the fan.) Example Q': Motion airflow (m3/min) Q'= V = 100 (W) 0.33 (m3/min) 20T 20 x15 (K) 3. Selecting the fan After the motion airflow has been calculated, select an appropriate fan motor based on the value.The motion airflow when the fan motor is actually mounted in your system can be obtained using the airflow-static pressure characteristics curve and system impedance.However, the system impedance cannot be measured without a measuring equipment, so fan with 1.5 to 2 times higher airflow than the actual max airflow should be selected (operating airflow is one-third to two-thirds of maximum airflow). Example Characteristics of airflow versus static pressure Q: Maximum airflow (m3/min) Q'=Qx2/3 Q=Q'x3/2=0.33x3/20.5 (m3/min) Next, In case that you select a fan having an airflow of 0.5 (m3/min) or more and a appropriate size for the space inside your system. For example, If you need a fan of 60 mm square, 25 mm thickness and 12 V, you should select is 109R0612H402 (maximum airflow = 0.53 m3/min). and those of pressure losses of equipment Static pressure System impedance Pressure loss 4. Confirming the selected fan Calculate the temperature rise inside your sysetem when your sysetem having 100 (W) of total heating value is forcefully cooled down by a 109R0612H402 fan. Example Q' =Qx2/3=0.53x2/30.353 (m3/min) T =V/20Q'=100 (W)/20x0.353 (m3/min)14.2 (K) From the above, the temperature rise inside your system is calculated as 14.2 (K). Operating airflow Airflow Since the value obtained from the above equation is only a rough target, final fan selection should be based on your actual installation test. Portable measuring device for measuring airflow and system impedance within equipment San Ace Airflow Tester Features Enables the selection of the optimal fan for a device An optimal fan for a device can be selected by entering accurate measurement results into thermal design simulation software. Compact and lightweight With a compact design and weight of approximately 6 kg, it is portable enough to measure immobile equipment. Please refer to page 524 for detail. With connection duct mounted 548 DC AC Specifications for DC Fan Sensors Pulse sensor (Tach output type) example DC Pulse sensor outputs two pulse waves per revolution of fan, and it is good to detect fan speed. Pulse sensors can be incorporated in all kinds of DC fans. * Noise from inside the fan or from external devices may effect sensor output. Contact us for more information. The specifications listed below are for the 9G1212H101 model, and vary with the model number used. Please contact your point of sale for details. Output circuit Output waveform (Need Open collector In case of steady running One revolution T0 Specifications VCE = +30 V max. (For a 48 V-rated fan: Vce= +60 V max.) Ic10 mA max. [Vol=Vce (SAT)= 0.4 V or less] T1 T3 T4 VOL 0V - T2 VOH Inside of DC fan SENSOR pull-up resistor) T1 to 4 (1/4) T0 60 T1 to 4 (1/4) T0= 4N (s) N= Fan speed (min-1) Resistor +30 V max. Ic10 mA max. Sensor output * If you want detailed specifications that apply when the rotor is locked, please contact SANYO DENKI. Locked rotor sensor (rotation / lock detection type) example DC Locked rotor sensor outputs fan status signals. It is good to check whether the fan is running or locked * Noise from inside the fan or from external devices may effect sensor output. * Regarding details of the reverse logic and specifications of lock sensor output signals, please contact SANYO DENKI. * Lock sensor can not be used in some models. Contact us for more information. The specifications listed below are for the 9G1212H1D01 model, and vary with the model number used. Please contact your point of sale for details. Output circuit Output waveform (Need Open collector Rotor running Specifications 0.5 or less VCE = +27.6 V max. For a 48 V fan VCE = +60 V max. Ic= 5 mA max. [VOL= VCE (SAT)= 0.6 V or less] For a 48 V fan: VCE (SAT)= 0.4 V or less Rotor running 3 or less VOL 0V Technical Material Time (s) - pull-up resistor) VOH Inside of DC fan SENSOR 5 or less Rotor locked Note: The output is completely at Vol with 0.5 s or less after power-up. Resistor +27.6 V max. Ic= 5 mA max. Sensor output 549 Technical Material Low-speed sensor (rotating speed detection type) example DC Low-speed sensor outputs a signal when fan speed goes down to trip point or less. It is good to detect cooling degradation of fan. *Noise from inside the fan or from external devices may effect sensor output, please. *If you want detailed specification and reverse signal output,please contact SANYO DENKI. *Low-speed sensors can not be used in some models. Contact us for more information. The specifications listed below are for the 9G1212H1H01 model, and vary with the model number used. Please contact your point of sale for details. Output circuit Inside of DC fan Open collector SENSOR Specifications VCE = +27.6 V max. Ic= 10 mA max. [VOL= VCE (SAT)= 0.5 V or less] - Sensor scheme Example 1: In case steady running Resistor +27.6 V max. Ic= 10 mA max. Sensor output Example 2: In case that the rotor is locked when the fan motor is turned on and released after the start-up delay time. Fan power Fan power Trip point Fan speed Trip point Fan speed Startup delay Sensor output Detected delay H Startup delay H Sensor output L Detected delay H H L VCE (SAT) Specifications for AC Fan Sensor ACDC fan sensor specifications differ from those below. Please refer to each product page. Specifications of sensor circuit AC 5 V (ITEM-20*) Example of model.no System Power supply Recommend sensor circuit output Nameplate 12 V (ITEM-30*) 109S405UL Speed detection, Auto-restart, Open collector 12 VDC 20% At 12 V, 10 mA 5 VDC10% At 5 V, 6 mA At Vp= 5 V, I= 100 mA max. At Vp= 12 V, I = 200 mA max. Standard speed: 1700 min -110% Low speed: 850 min -110% Trip point Standard speed: Startup delay 18 s Detection delay 1 s Low speed: Startup delay 36 s Detection delay 2 s 10 M min. at a 500 VDC megger (Note) 50/60 Hz, 1000 VAC, 1 minute (Note) Temperature: -10 to +70C , humidity: 90% RH max. (at 40C) Response speed Insulation resistance Dielectric strength Ambient conditions Sensor scheme Example 1: When the AC power for the fan and the DC power for the sensor are turned on at the same time *[ITEM-20] and [ITEM-30] are printed on the fan nameplate. Note: Between one end that all sensor leads consisting of brown, yellow and black are tied together and the G terminal or power terminal of the fan. Example 2: When the AC power for the fan is turned on first, then the DC power for sensor is powered on AC power for fan AC power for fan motor DC Power for sensor circuit Trip point Speed DC Power for sensor circuit Detection delay Trip point Sensor output Speed for fan Startup delay Detection delay Example 3: When the DC power for sensor is first powered on, then the AC power for the fan is turned on Detection delay Sensor output AC power for fan motor Circuit voltage Voltage between yellow and black leads Fan speed Trip point DC Power for sensor circuit VCE (SAT)= 0.1VTYP Startup delay Detection delay Sensor output Sensor output circuit 550 Brown 12 V (ITEM-30*) +4.5 V to +5.5 V Yellow 100 mA max. Pull-up resistor Black +27.6 V max. Sensor output GND (0 V) Sensor circuit Sensor circuit 5 V (ITEM-20*) Brown Yellow +9.6 V to +14.4 V 200 mA max. Pull-up resistor Black +27.6 V max. Sensor output GND (0 V) GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated. Fans with PWM Control Function PWM control function DC 1. Overview Pulse Width Modulation (PWM) control function enables you to externally control the speed of the fan by varying the duty cycles of PWM input signals between control and grounding terminals. It allows fans to operate optimally in response to the device's heat level, lowering the noise and power consumption of the system. Fan (Red) Power supply (Black) PWM signal generator (Brown) Control PWM control function has the following advantages: (1) Because the PWM signal is digitally input, precise control is possible. (2) Because the PWM signal is digitally input, multiple fans can be controlled. (3) Upon users request, how the fan speed responds to PWM signals can be customized. For example, fan can be set to stop or run at low speed at 0% PWM duty cycle. 2. PWM duty input signals and wiring diagram Other than a TTL input, an open collector/drain input can be used for PWM signal input. Be noted that if an open collector/drain input is used or applied an input voltage and frequency is out of specified range, how the fan speed responds to the PWM duty cycle may be altered. The input signal voltage and the frequency differ with models. Please contact us for details. Example VIH VIL T1 Wiring example of input signal (TTL input) VIH =4.75 to 5.25 V Inside of DC fan DC fan VIL= 0 to 0.4 V power PWM duty cycle (%) = T1x100 T Control PWM frequency 25 (kHz) = 1 T Terminal PWM Current source (Isource) = 1 mA max. (when control voltage is 0 V) Isource signal T Current sink (Isink) = 1 mA max. (when control voltage is 5.25 V) Isink Control terminal voltage = 5.25 V max. (when control terminal is open) When the control terminal is open, fan speed is the same as when PWM duty cycle is 100%. 3. PWM duty cycle - Speed characteristics Fan speed of PWM control fans change, as the below performance curve shows, in response to the PWM duty cycle input. If necessary, users can do the speed setting by themselves, making the fans operate at the optimum speed. Also, upon user's request, how fan speed responds to a PWM signal can be customized so that the fan stops or runs at low speed for a certain PWM duty cycle input. The below performance curve is for a fan that stops at 0% PWM duty cycle. Specifications differ with models. Please contact us for details. (min-1) 6000 Voltage: 12 VDC PWM frequency: 25 kHz 5000 Duty cycle=20% 5000 min-1 Fan speed 0V 4000 Duty cycle=50% 5V 2800 min-1 3000 56% (2800 min-1) of rated speed 0V 2000 Duty cycle=100% 5V 1000 0 Fan speed 16% (800 min-1) of rated speed 5V 800 min-1 0 20 Full speed (5000 min-1) 0V 50 100 (%) PWM duty cycle 4. When you wish to obtain a fan performance with 100 or 0% PWM duty cycle without a PWM signal generator for built-in test. Performance at 100% PWM duty cycle: Leave the control lead wire open and no connection. Performance at 0% PWM duty cycle: Connect the control lead wire directly to pin. Thermistor PWM control circuit Fan PWM Duty Cycle Here are a few application examples of PWM control fan. 1This system controls the fan speed in response to changing device temperature. By combining a PWM control circuit and thermistor that detects temperature of device and its parts, it is able to control the fan speed of PWM control fan in response to the changing temperature. Speed 5. Application examples of PWM control fan (min-1) 7000 6000 5000 4000 3000 2000 1000 0 -20 -10 0 10 20 30 40 50 60 70 (C) 60 70 (C) Temperature detected with thermistor (%) 100 80 60 40 20 0 -20 -10 0 10 20 30 40 50 Temperature detected with thermistor 551 Technical Material The dotted part of the performance curve (area below 20% PWM duty cycle in the above case) indicates the fan speed is unstable in the area. Technical Material 2Simultaneous control of multiple fans Because PWM control is done with digital signal inputs, regardless of fan types or input voltage, multiple fans can be controlled simultaneously. Below figure shows a system that can control multiple fans with various PWM characteristics simultaneously. Such systems contribute to the low power consumption and noise. Operation mode Full-power Normal Standby (eco mode) Fan A (model that stops at 0% PWM duty cycle) (min-1) Voltage: 12 VDC 5000 PWM frequency: 25 kHz Fan B Heat source PWM control circuit (min-1) Voltage: 12 VDC 5000 PWM frequency: 25 kHz 5000 min-1 3000 2000 1000 0 3000 2000 1000 0 100 (%) PWM duty cycle 0 100 (%) 0 PWM duty cycle Controlling device that easily regulates the rotational speed of PWM control fans DC San Ace PWM Controller Features Reduces system power consumption and fan noise For PWM fan speed control, a PWM control circuit needs to be newly designed and configured. By using this product, however, PWM control function fans can be fully utilized without the need for preparing new circuits, contributing to reducing the system power consumption and the fan noise. Can be common-powered by the fan power supply The controller can be powered by the fan power supply of rated voltage 12, 24, and 48 VDC, and no separate supply is required. Maximum of four fans connectable Up to four fans with PWM control function can be connected and controlled. Please refer to page 518 for detail. 552 5000 min-1 4000 Fan speed Fan speed Fan Fan B, C 5000 min -1 4000 min -1 1500 min -1 Fan B, C (model that runs at low speed at 0% PWM duty cycle) 4000 Fan C Fan 5000 min -1 3500 min -1 Stop PWM Duty 100% 60% 0% Box type PCB type Splash Proof Fan Ingress protection ratings (IP code) DC IP Codes used by SANYO DENKI express the level of protection that internal electrical components (for fans: electrical components and motor coils) have against solid objects, water, and access to hazardous parts. San Ace Splash Proof fans feature high protection levels. Protected electrical components and motor coils Definition of Ingress Protection (IP Code) Ingress Protection (IP Code) is defined in IEC (International Electrotechnical Commission) 60529* DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP Code). *IEC 60529:2001 I P X X Second digit: Protection against water First digit: Protection against solid objects and access to hazardous parts Definition 0 No protection 1 Protection against solid objects > 50 mm 2 Protection against solid objects > 12.5 mm 3 Protection against solid objects > 2.5 mm 4 Protection against solid objects > 1 mm 5 Protection against a level of dust that could hinder operation or impair safety 6 Complete protection against dust Second digit Definition 0 No protection 1 Protection against dripping water 2 Protection against water spray up to 15 3 Protection against spraying water 4 Protection against splashing water 5 Protection against low pressure water jets 6 Protection against high pressure water jets 7 Protection against temporary immersion in water 8 Protection against submersion in water Technical Material First digit 553 Technical Material UPS, inverter, rectifier, high-voltage power supply, etc. Cautions for Use of a Cooling Fan in the Vicinity of a Power Switching Circuit (prevention of electrolytic corrosion) If a fan is installed near a large-power or high-voltage switching circuit, the heavy electromagnetic noise resulting from electromagnetic induction in such circuits or the influence of high-frequency noise imposed through the power line of the fan may induce current through the shaft bearing of the fan. Such current may damage the oil film on the bearing and even the friction surface of the bearing. This adverse effect is known as "electrolytic corrosion of the fan. "Electrolytic corrosion affects the smooth revolution of the fan and may reduce its service life. An audible symptom is unusual noise emitted from the fan. This adverse effect is often observed and may partly be explained by the practice of mounting high-density parts, which reduces the gap between the switching circuits and the fan and the use of higher switching frequencies apt to provoke induction. Data processing/communications devices that operate at low voltages are not liable to electrolytic corrosion since they generate less electromagnetic noise. A Case of electrolytic corrosion DC No. 1 2 3 4 5 Use Switching power supply UPS General-purpose inverter Air cleaner Inverter for LCDs Period until the occurrence of unusual noise 6 months to 2 years 6 months to 2 years 1 to 1.5 years 2 to 3 months 6 months The curve shown in the graph below represents the relationship between the level of the electromagnetic noise induced by a fan and the distance from the fan to the noise source. Level of noise induced by a fan Fans without anti-corrosion features installed near components that generate electromagnetic noise, such as inverter controllers, are liable to experience electrolytic corrosion. AC Range in which electrolytic corrosion is generated Range in which electrolytic corrosion is not generated Distance from the noise source to the fan Occurrence of electrolytic corrosion Pattern 1 (1) The fan gets charged with high-frequency electricity by high-frequency noise (electric field/magnetic field) generated in the switching circuit. (2) Because of high-frequency electricity charged in the fan, an electric current flows through the bearing of the fan. (3) The electric current breaks the oil membrane on the surface of the bearing and the bearing gets abraded (electrolytically corroded). (4) This symptom often occurs in equipment in which switching circuits are sped up and implemented in high density. (5) Countermeasure 1: To provide a shield plate* inside the fan (The plate should be such that does not interfere with airflow). (6) Countermeasure 2: To use a fan with ceramic bearings. Fan cabinet Switching circuit board of the equipment Component parts of the switching circuit Propeller Wind Pattern 1 Electric field/magnetic field of the high-frequency electricity Shielding metal Occurrence of electrolytic corrosion Pattern 2 (1) High-frequency electricity flows from the circuit board into the inside of the fan superimposed with the power line for the fan. (2) High-frequency electricity that has entered into the fan flows through the bearing. (3) Oil membrane on the surface of the bearing gets broken and the bearing gets abraded (electrolytically corroded). (4) Countermeasure 1: To remove high-frequency component between terminals "a" and "b", "a" and "e" and "b" and "e" of the power supply for the fan, or to insert a filter** into the power line for the fan. (5) Countermeasure 2: To use a fan with ceramic bearings (6) Cables should be twisted in order to decrease induction to the power line for the fan. + terminal a Power supply for the fan 0Vterminal Mounting screw Grounding to the cabinet b Pattern 2 High-frequency electricity is superimposed onto the power line for the fan. Circuit board grounding e Metal cabinet of the equipment Return path of the high-frequency electricity * Shielding metal plate As an electromagnetic shield metal, "EMC Guard" is available from our company. http://www.sanyodenki.co.jp/product /newfan/indexf.html Certain shielding effect can be expected from mounting a general-purpose finger guard inside the fan. In each case, grounding to the cabinet is required. ** Filter Insert a common mode filter when the high-frequency electricity is superimposed on both lines "a" and "b" in the same phase and, if not, insert a normal mode filter. Measures against electrolytic corrosion DC AC Relocate fans far from all electromagnetic noise sources. Attach an EMC guard to ordinary fans. This should have an effect on electromagnetic noise due to radiation. As a power supply, the fan is wired from a circuit for which noise is not superimposed. Against heavy electromagnetic noise (electromagnetic induction) and conductive noise from the power supply line for a fan, we recommend the use of an "Electrolytic corrosion proof fan" with ceramic bearing. This cooling fan prevents electrolytic corrosion of bearings even under conditions where electromagnetic noise is generated. Electrolytic corrosion of ball bearings is prevented by using ceramic balls in ball bearings. The ceramic material is an insulating material. Manufacturable to meet specifications of all San Ace series fans. Component diagram Impeller Caution Magnet Stator Coil 554 Bearing: Ball Bearing (Material of ball: Ceramic) Electrolytic Corrosion Proof Fan has been designed to prevent the electrolytic corrosion of ball bearings in the fan, but this does not guarantee that the fan will operate normally under conditions where there is strong electromagnetic noise. Please be sure to fully evaluate the value of fan malfunction due to noise in advance. Safety Standards List of safety standards acquired refer to the index (pp. 561 ro 585) Description of safety standards 1. UL ratings (USA) PS E 2. CSA standards The Canadian Standards Association (CSA) was set up in response to the advice of the Canadian government. In Canada, the law prohibits the use and sale of any product other than those approved under CSA in terms of safety. CSA has set up CSA standards as inspection procedures and other requirements to ensure product safety. Our products are certified as satisfying the CSA standard C22.2 No. 113. EN standards (EU members) In the EU territory, the harmonization of industrial standards and safety standards of different countries is under way. The unified standards are called Harmonized Standards. Each of these standards is marked EN above the standard number. EN standards offer the grounds in design and manufacture when one exports a product to the EU territory. In order for a product to receive a safety marking, the product must be found to conform to TUV, VDE, or other relevant standard. Our products are certified as satisfying all TUV Rheinland EN60950/EN62368 requirements. (Canada) 3. 4. Electrical appliance and material safety law 5. Underwriters Laboratories Inc. was established by the American Union of Fire Insurance Underwriters. The purpose of UL is to ensure safety of machines, equipment, and materials and protect human lives and property from fire and other accidents. To that end, UL has conducted numerous tests and extensive research and, as a result, set up UL ratings. Any seller of products in any of the majority of the states of the USA must produce their products according to the UL ratings, have them pass UL-specified safety inspections, and have them listed in UL's registration book. Therefore, to export and sell any product in the United States, one must in most cases apply for UL-listing. Additionally, UL is accredited by The Standards Council of Canada (SCC) as both a Certification Organization (CO) and a Testing Organization (TO) and is officially recognized in all provinces and territories throughout Canada. Accordingly, our products can be tested by UL for compliance with Canadian safety standards. Certified products are entitled to display the C-UL Mark, which authorizes their use and sale in Canada. If products are deemed to be compliant with both U.S. and Canadian standards, then both the UL Mark and C-UL Mark can be displayed or a combination U.S. and Canadian mark (bottom left). Our products are certified as satisfying all UL 507 requirements. CE marking CE marking As of April 1, 2001, the Electrical Appliance and Material Control Law has been revised and reenacted as the Electrical Appliance and Material Safety Law. AC fans are classified as Blowers under Electric motor-operated appliances . They are categorized as electrical products other than specific electrical appliances (with the exception of some models) and are required to be labeled to indicate PSE certification. To distribute their equipment in the EU territory, manufacturers are obligated to give a CE marking as proof that the equipment conforms to related EC directives. Manufacturers use EN standards as criteria of judgment as to whether the equipment satisfies the requirements of specific directives or, in the absence of applicable EN standards, they use IEC standards. Manufacturers then prepare a self-declaration to indicate that the equipment conforms to related directives and apply a CE marking. (Depending on the degree of risk of the equipment, some kinds of equipment are required to receive type tests conducted by certified authorities and, after a type test certificate is obtained, manu-facturers make a self-declaration.) Scope of application and compulsory timing of major EC directives Machine directives These directives apply to equipment that has a moving part that may injure humans. The directives generally apply to a wide range of machine tools and other industrial machines. EMC directives They apply to equipment which may be affected by electromagnetic interference (EMI) or has ele-ctromagnetic susceptibility (EMS). Low-voltage directive This directive applies to equipment that is used in an AC range between 50 and 1000 V and in a DC range between 75 and 1500 V. Standards and Certifications PS E Standards and Certifications JIS: Japanese Industrial Standards Japan's national standards related to mining and manufacturing industries IEC : International Electrotechnical Commission This is an international commission on electrical standardization. This commission promotes the unification and cooperation of international standards related to electric and electronics engineering and issues IEC standards in order eventually to allow different countries to conform to the international standards. DIN : Deutsches Institut fur Normung e.V. This is a German standards institute. The institute uses a wide-range set of standards covering many industrial sectors. The set of standards includes basic standards. VDE : Verband Deutscher Elektrotechniker e.V. It is a German association of electric engineers. VDE establishes safety standards related to electrical engineering and issues them as DIN-VDE standards. 555 Standards and Certifications RoHS Directive Since October 2012, all the products in this catalog have complied with the maximum concentration values of the hazardous substances referred to in the Annex II to EU RoHS Directive 2011/65/EU,* except for the exempted applications specified in the Annex III to the Directive. Please note that SANYO DENKI does not use exemption 7(c)-III: Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 VAC or 250 VDC, for those products. * Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) RoHS Directive: DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Eco-products Efforts for designing Eco-products As for product design, we are carrying out R&D to incorporate the latest energy-saving technologies into our new products. At the same time, we carry out product assessments to evaluate the environmental impact of products at each stage, such as component and material procurement, manufacture, distribution, use, recycling, and disposal. Newly developed products are compared with commercially available and existing products and are certified as Eco-products (Eco-design products) if they satisfy the specified evaluation standards. Eco-products are presented in catalogues and other materials with a LEAF symbol. Life cycle assessment (LCA) LCA is one of the techniques used to provide a general quantitative measure of levels of environmental impact including global warming that products have through their life cycles. We evaluate the environmental compatibility of a product using this method. Our rate of implementing LCA in our Ecoproducts was 90%. 556 Please Read: Operating Precautions DC AC Temperature conditions Operating temperature: Refer to the specifications table for each model. Storage temperature: -20 +70C / -30 +70C (Varies for each model / Non condensing) * Rapid change in temperature may cause condensation. Prevent condensation when storing. Condensation may affect lubrication performance and insulation. Power specifications For the specification of rated voltage and voltage range, please check the catalog or drawing for the model number. Use of voltage exceeding the specified range may lead to performance degradation, device failure, or fire hazards. Do not apply voltage that exceeds specifications to the fan. An electronic circuit is used for the DC fan. For power supply, use power with ripple less than 5% with low line noise and surge to prevent electronic circuit trouble. Handling precautions The fan motor is equipped with a precision ball bearing. Therefore, please handle the motors carefully in order not to shock the bearings. Installation tips There are no limitations on the installation direction of fans or blowers. Fans have symbols on the fan indicating the airflow direction and blade rotation direction. When installing, use these symbols to check the airflow direction. Airflow direction Discharge side Suction side Blade rotation direction Symbols indicating the fan airflow direction and blade rotation direction Recommended screw torque This shows the recommended values for the screw torque when installing the fans. If the tightening torque is higher than the recommended values, the fan can be deformed or damaged. Use care when tightening. Also, be sure to always use a fan with a ribbed structure when securing by screws with both flanges. DC fan Fan mounting hole diameter [mm] o3.5 o4.3, o4.5 o4.3, o4.5 AC fan Nominal screw Recommended screw torque diameter M3 0.44 Nm max. M4 0.78 Nm max. 0.98 Nm max. (o172 mm x 51 mm, o172 mm x 150 mm x 51 mm M4 o200 x 70 mm) Fan mounting hole diameter [mm] o3.5, o3.7 o4.3 o4.3 o5.5 Nominal screw Recommended screw torque diameter M3 0.44 Nm max. 0.58 Nm max. M4 (120 mm x 120 mm max.) 0.78 Nm max. M4 (ACDC fan, o172 mm) 0.78 Nm max. M4, M5 (160 mm x 160 mm) Rib Ribbed Ribless Securing with flanges on both sides Securing with a flange on one side 557 Please Read: Comparison of ribbed and ribless structures Regarding plastic frame, we have a option ribbed and ribless about mounting. Please use preferred type up to your application. Please use ribbed fan in case that you hook fan up clamping either side fan mounting hole target. (According to the model, only models with or without ribs are available.) *Use a fan with a rib structure when securing by screws with both flanges. When securing screws to ribless plastic frame models, use a flange to secure on one side. Please Read: Fan Mounting Using Self-tapping Screw DC Installing self-tapping screws into the plastic frame of the fan may split or deform it. If using self-tapping screws, use screws that are recommended by our company, and refer to our recommended tightening torques and recommended pilot hole shapes. Pay close attention to the operating precautions and fully understand your equipment before you use it. Recommended screw torques Recommended self-tapping screws Material: Steel Plating: Trivalent chromating plating o3.5 o4.3 o4.5 Flat Head shape: 0.8 max. Counter rotating fan (Fig. B) 0.6 max. D 120 L Ribbed fan (Fig. A) Fan mounting hole diameter [mm] H Recommended screw torque [N*m] D Fig. B: Counter rotating fan Pan Head shape: L Fig. A: Ribbed fan unit: mm Flat-head/pan-head dimensions Nominal Self-tapping screw Length Head Head Height of Cross screw model no. [L] shape diameter head recess diameter [D] [H] No. Flat 6.2 1.1 max. 2 SY-NS020412P11 4 12 SY-NS010412P11 4 12 Pan 5.5 2.0 2 SY-NS024812P15 4.8 12 Flat 6.8 1.2 max. 2 SY-NS014812P15 4.8 12 Pan 7.0 2.6 2 SY-NS020512P15 5 12 Flat 6.8 1.2 max. 2 SY-NS010512P15 5 12 Pan 7.0 2.6 2 o3.5o4.3o4.5 H Fan mounting hole diameter Operating precautions Do not use self-tapping screws in the following cases: For ribless fans (except for counter rotating fans) When mounting finger guards on fans Using self-tapping screws could deform or split the frame. Please use regular screws. Recommended pilot hole shape Place the self-tapping screw so that it is vertical and centered with the frame mounting hole (Fig. A) and then screw it in. The self-tapping screw could deform or split the frame if you screw it into the frame when the screw is not vertical. Screw in the self-tapping screw with the center of the mounting hole on the fan and the center of the pilot hole on the mounting plate aligned (Fig. B). Misaligned holes could lead to the frame being deformed or split. [For nominal diameter 4 mm] 0.5 min. 0.5 Self-tapping screw model no. SY-NS020412P11 Self-tapping screw model no. SY-NS010412P11 120 o4.6 Plate Fan frame o4.6 Plate Fan frame Vertically placed screw Inclined screw Fig. A Minimum mounting plate thickness: T=1.2 mm [For nominal diameters of 4.8 mm and 5 mm] 0.5 min. 0.5 Self-tapping screw model no. SY-NS024812P15 SY-NS020512P15 Self-tapping screw model no. SY-NS014812P15 SY-NS010512P15 120 o5.6 o5.6 Plate Fan frame Minimum mounting plate thickness: T=1.2 mm Plate Fan frame Aligned and centered holes holes Misaligned Fig. B Tightening the screw beyond the recommended screw torque could deform or split the frame. With flat-head screws, failure to use the recommended pilot hole shape will cause interference between the flat-head screw and fan frame which could split the frame. Recommended screw manufacturer To purchase the screws, please contact the screw manufacturer directly. SAIMA CORPORATION 2-9-17 Tsujido Fujisawa Kanagawa 251-0047 JAPAN TEL:+81-466-36-3656 FAX:+81-466-36-0009 http://www.saima.co.jp/English/ 558 Safety Precautions DC AC To ensure that this product is used safely, be sure that you read and understand the following precautions fully and use the product only as directed. Be sure to read the Safety Precautions carefully before installing, connecting, operating, maintaining, or inspecting this product. Follow all the precautions and directions given here. This product has been designed and manufactured for use as a device to be used in general industrial machinery, and may not be used as a standalone product. The product of our company (hereinafter called the product) falls into the category of the products specified in the Attached List 1, Item 16 (Class 84, Item 14) of the Export Trade Control Ordinance. To export the product as an individual part or to export a product into which the product is assembled, the "Informing Requirements" and "Objective Requirements" that the Ministry of Economy, Trade and Industry of Japan established based on the "Catch-all Controls" must be studied for applicability. Accordingly, appropriate export formalities must be performed. When disposing the product, treat it as industrial waste. Please contact your local government office for further details about disposal. To prevent any possible bodily injury or damage to property or equipment, the following precautions for ensuring safety are displayed according to the following two ranks of importance: Danger Handling or using the product improperly and in disregard of the instructions with this mark may result in serious bodily injury or death. Caution Handling or using the product improperly and in disregard of the instructions with this mark may result in bodily injury or physical damage. Note: Items marked Caution may also result in serious bodily injury or death in some circumstances. Always follow the instructions the same as for items marked Danger. Descriptions of the precautions to be taken to ensure safety are given below. Danger When using the product in the following environments, use it at your own discretion only after deploying sufficient safety measures and making prior evaluations. Equipment such as medical equipment related to human life, facilities that have serious social and public effects, or environments with vibrations such as in automobiles or ships. Ensure that wiring has been correctly done. Failure to do so may result in fire, burns, or electrical shock. If there are any grounding taps or wires, ground them securely. There is danger of electric shock. Never use in explosive atmospheres, as doing so might result in fires, burns, or bodily injury. Otherwise, it may result in fire, burns, bodily injury, or electrical shock. Do not operate the product when electronic components are exposed. There is danger of electric shock. Never allow any persons or objects to approach or come into contact with the rotor while in operation, as doing so might result in damage or personal injury. Turn off the power and stop using the product immediately if you notice any sparks, smoke, odd odors, sounds, or anything unusual during operation. There is danger of electrical shock, fires, or bodily injury. Never allow the product to fall, topple over, or otherwise be subjected to excessive shocks when moving it, as doing so might result in product breakdown or substandard operation. The product should be handled only by personnel with sufficient training and knowledge and under the responsibility of the end user. Never attempt to disassemble or alter this product in any way. There is danger of electrical shock, fires, or bodily injury. Cautions for operation Give proper consideration to the device for its protection in case the fan stops during operation. Never use the product at voltages, temperatures, or any other settings which exceed those given in the product specifications. This might result in substandard operation, breakdown, fire, bodily injury, or electrical shock. The fan may fail to operate properly if there is insufficient power capacity, because a starting current several times larger than the rated current will flow at the moment voltage is supplied to the fan. Be sure to inquire about starting current levels for individual models. Do not control the speed of the fan by changing power voltage using PWM. It may cause fan failure. Start all fans at the same time when two or more fans whose wind creates interference are installed in the device. If the fan is exposed to wind from other fans at startup, it may cause fan failure or the fan may not start up correctly. Never insert or remove any lead wires, plug cords or connectors while the power is turned on. Turn off the fan then, while holding the frame, insert or remove plugs or connectors. Failure to do so might result in damage or electrical shock. Do not remove the lead wire of the fan from the frame hook. Doing so may scratch and damage the surface of the lead wire. Do not remove the nameplate. There is danger of electrical shock or failure. Do not push the nameplate of the fan with strong force. The nameplate may break or come in contact with the shaft. The product might become damaged if foreign objects or external forces interfere with normal fan operation. Do not implement ON-OFF on the negative power supply line. That might damage the fan. 559 Please Read: Caution Handling Installation, placement, connections, wiring, or relocation of the product should be performed by knowledgeable or correctly licensed personnel. Never perform such work while the product is on, as this might lead to injury, electrical shock, burns, or fire. Do not use the fan if it is not fixed, nor while held in hand. Never allow yourself to come into contact with the ends of wires or plugs when measuring insulation resistance or dielectric strength voltage. There is danger of electric shock. Never attempt to disassemble or alter this product in any way. Doing so may invalidate any warranties concerning the functions or performance of the product, and may also result in fire, burns, bodily injury, or electrical shock. Please Read: Caution Installation When fixing this product into place, be sure to take the product's weight, vibrations generated during operation, and all other relevant factors into consideration. Failure to do so may result in the product or its parts falling, resulting in bodily injury or device failure. Be sure to check the installation direction (i.e., the fan), as failing to do so might result in bodily injury or mechanical breakdown. To ensure that the product operates properly, allow spaces for ventilation and take necessary steps to prevent the entry of foreign objects. Failure to do so might result in bodily injury or mechanical breakdown. When fixing the fan with screws, make sure the screw and sheet metal have not deformed the frame of the fan before operation. If the frame of the fan is deformed, mechanical failure may occur or specified performance may not be achieved. When fixing the fan with screws, ensure the screwing torque. If the screwing torque exceeds the recommended torque, the fan frame may be deformed or damaged. Use a ribbed frame when using screws to affix fans with plastic frames. To prevent loose screws, use plain washers or spring lock washers. For the screwing torque of each fan type, contact SANYO DENKI or a SANYO DENKI distributor. When fixing the fan with self-tapping screws, the fan frame may be damaged. When excessive shock is applied to the fan, the impeller may protrude from the surface of the fan frame. Make sure that the impeller does not touch covers, such as finger guards or mounting plates. Do not subject fans to excessive shock to avoid fan failure and performance deterioration. Pulling or pinching lead wires could result in damage to the wire; avoid placing excessive stress on wires. The device should be installed so that the lead wires do not come into contact with the rotor or blades. Failure to do so might result in damage or electrical shock. Take proper precautions against static electricity when making electrical connections. Failure to do so might cause the breakdown of the fan or device. Install a finger guard or other cover if there is any danger of fingers, hands, or objects coming into contact with the rotor or blades. Failure to do so might result in bodily injury or mechanical breakdown. Install finger guards, filters, and plates in the correct position while avoiding touching the rotor blade. Avoiding this will prevent device failure. Please use only genuine SANYO DENKI finger guards and filter kits. Make electrical connections properly. If not there is a possibility that the device might break, or that the product might malfunction, breakdown, or have degraded performance. Installation of Centrifugal Fan Use screws to affix the fan. For screw size of each fan type, refer to drawing or catalog. Do not use screws whose length exceeds the depth of the mounting screws. If the screw hole is damaged it may not be possible to affix the fan. For screw size of each fan type, refer to drawing or catalog. When fixing the fan with screws, ensure the screwing torque. If the screwing torque exceeds the recommended torque, the screw hole may be deformed or damaged. To prevent loose screws, use plain washers or spring lock washers. For the screwing torque of each fan type, contact SANYO DENKI or a SANYO DENKI distributor. Install the inlet nozzle, finger guard, and plate to the fan in the correct position while avoiding touching the rotor blade. Avoiding this will prevent device failure. Please use only genuine SANYO DENKI inlet nozzles. Operating environment Avoid using or storing the product in the following areas and environments. There is the possibility that a fire may occur, the product may malfunction, or its performance may deteriorate. Flammable or corrosive gas atmospheres, in places where water or oil splashes (excluding to Splash Proof or Oil Proof Fans), in places where there is much dust or humidity, in places where condensation occurs, in places where the product is exposed to radioactive rays or is in direct sunlight, in places where a salty sea breeze blows or seawater splashes, or in an environment where the product may be contaminated by such corrosive materials as sulfurous water, sulfurous volcanic ash, organic solvents, acidic chemicals, alkali chemicals, etc., or such hazardous substances as nuclear fuel materials, etc. Avoid using or storing the product in the following areas and environments. Doing so might result in product breakdown or substandard operation. Environments where it could be constantly exposed to vibrations, strong shocks, centrifugal force, acceleration (excluding G Proof Fans), magnetic or electromagnetic noise, areas in which the electromagnetic noise overlaps into power voltage, or areas subjected to rapid environmental fluctuations (temperature, humidity, etc.) Maintenance Maintenance and inspections should always be performed by personnel with sufficient training and knowledge. Otherwise, it may result in fire, burns, bodily injury, or electrical shock. Never perform any maintenance or inspections while the product is in operation. Also note that the blades continue to rotate for some time immediately after operation ceases. Always confirm that all rotating parts have come to a stop before beginning work. Otherwise, it may result in bodily injury. Never use gasoline, paint thinner, benzene, or other organic solvents to clean the product, as this could result in deformation or substandard operation. 560 Index by Model No./Safety Standards List - DC Fans DC Standard List of models Without sensor 109BC12FC7-1 109BC12GC7-1 109BC12HC7-1 109BC12MC7-1 109BC24FC7-1 109BC24GC7-1 109BC24HC7-1 109BD12FC2 109BD12HC2 109BD12MC2 109BD24FC2 109BD24HC2 109BD24MC2 109BG12HC1 109BG12MC1 109BG24HC1 109BG24MC1 109BJ12HC2 109BJ12MC2 109BJ24HC2 109BJ24MC2 109BM12GC2-1 109BM12HC2-1 109BM12MC2-1 109BM24GC2-1 109BM24HC2-1 109BM24MC2-1 109E1312A101 109E1312S101 109E1324A101 109E1324G101 109E1324S101 109E1348A101 109E1348G101 109E1348S101 109E1712F501 109E1712H501 109E1712K501 109E1712M501 109E1712Y501 109E1724C501 109E1724F501 109E1724H501 109E1724K501 109E1724M501 109E1748C501 109E1748F501 109E1748H501 109E1748K501 109E1748M501 109E4712L401 109E4712M401 109BC12FA7-1 109BC12GA7-1 109BC12HA7-1 109BC12MA7-1 109BC24FA7-1 109BC24GA7-1 109BC24HA7-1 109BD12FA2 109BD12HA2 109BD12MA2 109BD24FA2 109BD24HA2 109BD24MA2 109BG12HA1 109BG12MA1 109BG24HA1 109BG24MA1 109BJ12HA2 109BJ12MA2 109BJ24HA2 109BJ24MA2 109BM12GA2-1 109BM12HA2-1 109BM12MA2-1 109BM24GA2-1 109BM24HA2-1 109BM24MA2-1 109E1312A102 109E1312S102 109E1324A102 109E1324G102 109E1324S102 109E1348A102 109E1348G102 109E1348S102 109E1712F502 109E1712H502 109E1712K502 109E1712M502 109E1712Y502 109E1724C502 109E1724F502 109E1724H502 109E1724K502 109E1724M502 109E1748C502 109E1748F502 109E1748H502 109E1748K502 109E1748M502 109E4712L402 109E4712M402 With pulse sensor 109BC12FC7-1 109BC12GC7-1 109BC12HC7-1 109BC12MC7-1 109BC24FC7-1 109BC24GC7-1 109BC24HC7-1 109BD12FC2 109BD12HC2 109BD12MC2 109BD24FC2 109BD24HC2 109BD24MC2 109BG12HC1 109BG12MC1 109BG24HC1 109BG24MC1 109BJ12HC2 109BJ12MC2 109BJ24HC2 109BJ24MC2 109BM12GC2-1 109BM12HC2-1 109BM12MC2-1 109BM24GC2-1 109BM24HC2-1 109BM24MC2-1 109E1312A101 109E1312S101 109E1324A101 109E1324G101 109E1324S101 109E1348A101 109E1348G101 109E1348S101 109E1712F501 109E1712H501 109E1712K501 109E1712M501 109E1712Y501 109E1724C501 109E1724F501 109E1724H501 109E1724K501 109E1724M501 109E1748C501 109E1748F501 109E1748H501 109E1748K501 109E1748M501 109E4712L401 109E4712M401 With lock sensor 109BC12FD7-1 109BC12GD7-1 109BC12HD7-1 109BC12MD7-1 109BC24FD7-1 109BC24GD7-1 109BC24HD7-1 109BD12FD2 109BD12HD2 109BD12MD2 109BD24FD2 109BD24HD2 109BD24MD2 109BG12HD1 109BG12MD1 109BG24HD1 109BG24MD1 109BJ12HD2 109BJ12MD2 109BJ24HD2 109BJ24MD2 109BM12GD2-1 109BM12HD2-1 109BM12MD2-1 109BM24GD2-1 109BM24HD2-1 109BM24MD2-1 109E1312A1D01 109E1312S1D01 109E1324A1D01 109E1324G1D01 109E1324S1D01 109E1348A1D01 109E1348G1D01 109E1348S1D01 109E1712F5D01 109E1712H5D01 - - - 109E1724C5D01 109E1724F5D01 109E1724H5D01 109E1724K5D01 109E1724M5D01 - - 109E1748H5D01 - - 109E4712L4D01 109E4712M4D01 Frame size With PWM control function and pulse sensor - - - - - - - - 109BD12P2H01 - - - - - - - - - - - - - - 109BM12P2M01 - - - - - - - - - - - - - - - - 9EH1724P5C01 - - - - - - - 109E1748P5K03 - - - UL CSA TUV cULcUL 52 x 15 mm 52 x 15 mm 52 x 15 mm 52 x 15 mm 52 x 15 mm 52 x 15 mm 52 x 15 mm 76 x 30 mm 76 x 30 mm 76 x 30 mm 76 x 30 mm 76 x 30 mm 76 x 30 mm 160 x 40 mm 160 x 40 mm 160 x 40 mm 160 x 40 mm 127 x 32 mm 127 x 32 mm 127 x 32 mm 127 x 32 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - No No No No No No No No No No No No No No No No No No No No No No No No No 454 454 454 454 454 454 454 458 458 458 458 458 458 473 473 473 473 471 471 471 471 467 467 467 467 467 467 190 190 190 190 190 190 190 190 216 216 216 216 216 216 216 216 216 216 216 216 216 216 216 203 203 Please contact your point of sale regarding low-speed sensors. Standard name Certification number UL E46810 CSA 172248 TUV certification numbers differ by model. The content of this catalog is current as of September 2018. Please ask us about new products that we released after September 2018 if you want. 561 Index by Model No. Models listed in the main section of this catalog (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 109E4724F401 109E4724H401 109E4724L401 109E4724M401 109E4748F401 109E4748H401 109E4748L401 109E4748M401 109E4748S401 109E5712F501 109E5712H501 109E5712K501 109E5712M501 109E5712Y501 109E5724C501 109E5724F501 109E5724H501 109E5724K501 109E5724M501 109E5748C501 109E5748F501 109E5748H501 109E5748K501 109E5748M501 109L1712H501 109L1712M501 109L1724H501 109L1724M501 109L1748H501 109L1748M501 109L5712H501 109L5712M501 109L5724H501 109L5724M501 109L5748H501 109L5748M501 109P0405F3013 109P0405F601 109P0405H3013 109P0405H601 109P0405H701 109P0405H901 109P0405J601 109P0405M601 109P0405M701 109P0405M901 109P0412B3013 109P0412D601 109P0412E601 109P0412F3013 109P0412F601 109P0412G3013 109P0412G601 109P0412H3013 109P0412H601 109P0412H701 109P0412H901 109P0412J3013 109P0412K3013 109P0412M3013 109P0412M601 109E4724F402 109E4724H402 109E4724L402 109E4724M402 109E4748F402 109E4748H402 109E4748L402 109E4748M402 109E4748S402 109E5712F502 109E5712H502 109E5712K502 109E5712M502 109E5712Y502 109E5724C502 109E5724F502 109E5724H502 109E5724K502 109E5724M502 109E5748C502 109E5748F502 109E5748H502 109E5748K502 109E5748M502 109L1712H502 109L1712M502 109L1724H502 109L1724M502 109L1748H502 109L1748M502 109L5712H502 109L5712M502 109L5724H502 109L5724M502 109L5748H502 109L5748M502 109P0405F3023 109P0405F602 109P0405H3023 109P0405H602 109P0405H702 109P0405H902 109P0405J602 109P0405M602 109P0405M702 109P0405M902 109P0412B3023 109P0412D602 109P0412E602 109P0412F3023 109P0412F602 109P0412G3023 109P0412G602 109P0412H3023 109P0412H602 109P0412H702 109P0412H902 109P0412J3023 109P0412K3023 109P0412M3023 109P0412M602 With pulse sensor 109E4724F401 109E4724H401 109E4724L401 109E4724M401 109E4748F401 109E4748H401 109E4748L401 109E4748M401 109E4748S401 109E5712F501 109E5712H501 109E5712K501 109E5712M501 109E5712Y501 109E5724C501 109E5724F501 109E5724H501 109E5724K501 109E5724M501 109E5748C501 109E5748F501 109E5748H501 109E5748K501 109E5748M501 109L1712H501 109L1712M501 109L1724H501 109L1724M501 109L1748H501 109L1748M501 109L5712H501 109L5712M501 109L5724H501 109L5724M501 109L5748H501 109L5748M501 109P0405F3013 109P0405F601 109P0405H3013 109P0405H601 109P0405H701 109P0405H901 109P0405J601 109P0405M601 109P0405M701 109P0405M901 109P0412B3013 109P0412D601 109P0412E601 109P0412F3013 109P0412F601 109P0412G3013 109P0412G601 109P0412H3013 109P0412H601 109P0412H701 109P0412H901 109P0412J3013 109P0412K3013 109P0412M3013 109P0412M601 With lock sensor 109E4724F4D01 109E4724H4D01 109E4724L4D01 109E4724M4D01 109E4748F4D01 109E4748H4D01 109E4748L4D01 109E4748M4D01 109E4748S4D01 - 109E5712H5D01 109E5712K5D01 109E5712M5D01 - 109E5724C5D01 - 109E5724H5D01 109E5724K5D01 - - - 109E5748H5D01 - - 109L1712H5D01 109L1712M5D01 109L1724H5D01 109L1724M5D01 109L1748H5D01 109L1748M5D01 109L5712H5D01 109L5712M5D01 109L5724H5D01 109L5724M5D01 109L5748H5D01 109L5748M5D01 109P0405F3D013 109P0405F6D01 109P0405H3D013 109P0405H6D01 109P0405H7D01 109P0405H9D01 - 109P0405M6D01 109P0405M7D01 109P0405M9D01 109P0412B3D013 109P0412D6D01 109P0412E6D01 109P0412F3D013 109P0412F6D01 109P0412G3D013 109P0412G6D01 109P0412H3D013 109P0412H6D01 109P0412H7D01 109P0412H9D01 109P0412J3D013 109P0412K3D013 109P0412M3D013 109P0412M6D01 Please contact your point of sale regarding low-speed sensors. 562 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor - 109E4724P4H01 - - - - - - - - - 109E5712P5K04 - - 9EH5724P5C01 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 109P0412P3B013 - - - - - - 109P0412P3H013 - - 109P0412P9H01 9PH0412P3J013 9PH0412P3K033 - - UL CSA TUV cULcUL o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 147 x 25 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 40 x 40 x 10 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 40 x 40 x 10 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 40 x 40 x 10 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 20 mm No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 203 203 203 203 203 203 203 203 203 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 409 409 409 409 409 409 407 407 407 407 407 407 47 30 47 30 23 19 30 30 23 19 47 30 30 47 30 47 30 47 30 23 19 47 47 47 30 Standard List of models 109P0412M701 109P0412M901 109P0412R701 109P0412S701 109P0424B3013 109P0424B601 109P0424D601 109P0424F3013 109P0424F601 109P0424G3013 109P0424G601 109P0424H3013 109P0424H601 109P0424H701 109P0424J3013 109P0424R3013 109P0505M701 109P0512A701 109P0512H701 109P0512M701 109P0524A701 109P0524H701 109P0524M701 109P0605H701 109P0605M701 109P0612B701 109P0612H601 109P0612H701 109P0612K701 109P0612M601 109P0612M701 109P0612S701 109P0612W601 109P0624H601 109P0624H701 109P0624J701 109P0624M601 109P0624M701 109P0624S701 109P0624W601 109P0648H601 109P0812C601 109P0812H601 109P0812H701 109P0812M601 109P0812M701 109P0824H601 109P0824H701 109P0824M601 109P0824M701 109P0848C601 109P0848H601 109P1312H101 109P1312H1011 109P1312S101 109P1312S1011 109P1324H101 109P1324H1011 109P1324S101 109P1324S1011 109P1348H101 109P0412M702 109P0412M902 109P0412R702 109P0412S702 109P0424B3023 109P0424B602 109P0424D602 109P0424F3023 109P0424F602 109P0424G3023 109P0424G602 109P0424H3023 109P0424H602 109P0424H702 109P0424J3023 109P0424R3023 109P0505M702 109P0512A702 109P0512H702 109P0512M702 109P0524A702 109P0524H702 109P0524M702 109P0605H702 109P0605M702 109P0612B702 109P0612H602 109P0612H702 109P0612K702 109P0612M602 109P0612M702 109P0612S702 109P0612W602 109P0624H602 109P0624H702 109P0624J702 109P0624M602 109P0624M702 109P0624S702 109P0624W602 109P0648H602 109P0812C602 109P0812H602 109P0812H702 109P0812M602 109P0812M702 109P0824H602 109P0824H702 109P0824M602 109P0824M702 109P0848C602 - 109P1312H102 109P1312H1021 109P1312S102 109P1312S1021 109P1324H102 109P1324H1021 109P1324S102 109P1324S1021 109P1348H102 With pulse sensor 109P0412M701 109P0412M901 109P0412R701 109P0412S701 109P0424B3013 109P0424B601 109P0424D601 109P0424F3013 109P0424F601 109P0424G3013 109P0424G601 109P0424H3013 109P0424H601 109P0424H701 109P0424J3013 109P0424R3013 109P0505M701 109P0512A701 109P0512H701 109P0512M701 109P0524A701 109P0524H701 109P0524M701 109P0605H701 109P0605M701 109P0612B701 109P0612H601 109P0612H701 109P0612K701 109P0612M601 109P0612M701 109P0612S701 109P0612W601 109P0624H601 109P0624H701 109P0624J701 109P0624M601 109P0624M701 109P0624S701 109P0624W601 109P0648H601 109P0812C601 109P0812H601 109P0812H701 109P0812M601 109P0812M701 109P0824H601 109P0824H701 109P0824M601 109P0824M701 109P0848C601 109P0848H601 109P1312H101 109P1312H1011 109P1312S101 109P1312S1011 109P1324H101 109P1324H1011 109P1324S101 109P1324S1011 109P1348H101 With lock sensor 109P0412M7D01 109P0412M9D01 109P0412R7D01 109P0412S7D01 109P0424B3D013 109P0424B6D01 109P0424D6D01 109P0424F3D013 109P0424F6D01 109P0424G3D013 109P0424G6D01 109P0424H3D013 109P0424H6D01 109P0424H7D01 109P0424J3D013 - 109P0505M7D01 109P0512A7D01 109P0512H7D01 109P0512M7D01 109P0524A7D01 109P0524H7D01 109P0524M7D01 109P0605H7D01 109P0605M7D01 109P0612B7D01 109P0612H6D01 109P0612H7D01 109P0612K7D01 109P0612M6D01 109P0612M7D01 109P0612S7D01 109P0612W6D01 109P0624H6D01 109P0624H7D01 109P0624J7D01 109P0624M6D01 109P0624M7D01 109P0624S7D01 109P0624W6D01 109P0648H6D01 109P0812C6D01 109P0812H6D01 109P0812H7D01 109P0812M6D01 109P0812M7D01 109P0824H6D01 109P0824H7D01 109P0824M6D01 109P0824M7D01 109P0848C6D01 109P0848H6D01 109P1312H1D01 109P1312H1D011 109P1312S1D01 109P1312S1D011 109P1324H1D01 109P1324H1D011 109P1324S1D01 109P1324S1D011 109P1348H1D01 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - UL CSA TUV cULcUL 40 x 40 x 15 mm 40 x 40 x 10 mm 40 x 40 x 15 mm 40 x 40 x 15 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 20 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 20 mm 60 x 60 x 20 mm 80 x 80 x 20 mm 80 x 80 x 20 mm 80 x 80 x 15 mm 80 x 80 x 20 mm 80 x 80 x 15 mm 80 x 80 x 20 mm 80 x 80 x 15 mm 80 x 80 x 20 mm 80 x 80 x 15 mm 80 x 80 x 20 mm 80 x 80 x 20 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes No Yes No Yes - - 23 19 23 23 47 30 30 47 30 47 30 47 30 23 47 47 54 54 54 54 54 54 54 62 62 62 68 62 62 68 62 62 68 68 62 62 68 62 62 68 68 105 105 100 105 100 105 100 105 100 105 105 193 193 193 193 193 193 193 193 193 Please contact your point of sale regarding low-speed sensors. 563 Index by Model No. Without sensor Frame size With PWM control function and pulse sensor (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 109P1348H1011 109P1348S101 109P1348S1011 109P1412H101 109P1412M101 109P1424H101 109P1424M101 109P1448H101 109P1448M101 109R0605F401 109R0605F4011 109R0605H401 109R0605H4011 109R0605M401 109R0605M4011 109R0612D401 109R0612D4011 109R0612F401 109R0612F4011 109R0612G401 109R0612G4011 109R0612H401 109R0612H4011 109R0612J401 109R0612J4011 109R0612M401 109R0612M4011 109R0612S401 109R0612S4011 109R0624D401 109R0624D4011 109R0624F401 109R0624F4011 109R0624G401 109R0624G4011 109R0624H401 109R0624H4011 109R0624J401 109R0624J4011 109R0624M401 109R0624M4011 109R0624S401 109R0624S4011 109R0648G401 109R0648G4011 109R0648H401 109R0648H4011 109R0648J401 109R0648J4011 109R0805F401 109R0805F4011 109R0805M401 109R0805M4011 109R0812E401 109R0812E4011 109R0812F401 109R0812F4011 109R0812G401 109R0812G4011 109R0812H401 109R0812H4011 109P1348H1021 109P1348S102 109P1348S1021 109P1412H102 109P1412M102 109P1424H102 109P1424M102 109P1448H102 109P1448M102 109R0605F402 109R0605F4021 109R0605H402 109R0605H4021 109R0605M402 109R0605M4021 109R0612D402 109R0612D4021 109R0612F402 109R0612F4021 109R0612G402 109R0612G4021 109R0612H402 109R0612H4021 109R0612J402 109R0612J4021 109R0612M402 109R0612M4021 109R0612S402 109R0612S4021 109R0624D402 109R0624D4021 109R0624F402 109R0624F4021 109R0624G402 109R0624G4021 109R0624H402 109R0624H4021 109R0624J402 109R0624J4021 109R0624M402 109R0624M4021 109R0624S402 109R0624S4021 109R0648G402 109R0648G4021 109R0648H402 109R0648H4021 109R0648J402 109R0648J4021 109R0805F402 109R0805F4021 109R0805M402 109R0805M4021 109R0812E402 - 109R0812F402 109R0812F4021 109R0812G402 109R0812G4021 109R0812H402 109R0812H4021 With pulse sensor 109P1348H1011 109P1348S101 109P1348S1011 109P1412H101 109P1412M101 109P1424H101 109P1424M101 109P1448H101 109P1448M101 109R0605F401 109R0605F4011 109R0605H401 109R0605H4011 109R0605M401 109R0605M4011 109R0612D401 109R0612D4011 109R0612F401 109R0612F4011 109R0612G401 109R0612G4011 109R0612H401 109R0612H4011 109R0612J401 109R0612J4011 109R0612M401 109R0612M4011 109R0612S401 109R0612S4011 109R0624D401 109R0624D4011 109R0624F401 109R0624F4011 109R0624G401 109R0624G4011 109R0624H401 109R0624H4011 109R0624J401 109R0624J4011 109R0624M401 109R0624M4011 109R0624S401 109R0624S4011 109R0648G401 109R0648G4011 109R0648H401 109R0648H4011 109R0648J401 109R0648J4011 109R0805F401 109R0805F4011 109R0805M401 109R0805M4011 109R0812E401 109R0812E4011 109R0812F401 109R0812F4011 109R0812G401 109R0812G4011 109R0812H401 109R0812H4011 With lock sensor 109P1348H1D011 109P1348S1D01 109P1348S1D011 109P1412H1D01 - 109P1424H1D01 - - - 109R0605F4D01 - 109R0605H4D01 - 109R0605M4D01 - 109R0612D4D01 109R0612D4D011 109R0612F4D01 109R0612F4D011 109R0612G4D01 109R0612G4D011 109R0612H4D01 109R0612H4D011 109R0612J4D01 109R0612J4D011 109R0612M4D01 109R0612M4D011 109R0612S4D01 109R0612S4D011 109R0624D4D01 - 109R0624F4D01 109R0624F4D011 109R0624G4D01 109R0624G4D011 109R0624H4D01 109R0624H4D011 109R0624J4D01 109R0624J4D011 109R0624M4D01 109R0624M4D011 109R0624S4D01 109R0624S4D011 109R0648G4D01 109R0648G4D011 109R0648H4D01 109R0648H4D011 109R0648J4D01 - 109R0805F4D01 - 109R0805M4D01 - - - 109R0812F4D01 109R0812F4D011 109R0812G4D01 109R0812G4D011 109R0812H4D01 109R0812H4D011 Please contact your point of sale regarding low-speed sensors. 564 Frame size With PWM control function and pulse sensor - - - - - - - - - - - - - - - - - - - - - - - 109R0612P4J03 109R0612P4J061 - - - - - - - - - - - - 9RH0624P4J01 - - - - - - - - - - - - - - - - - - - - - - - (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) UL CSA TUV cULcUL 127 x 127 x 38 mm 127 x 127 x 38 mm 127 x 127 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm No Yes No Yes Yes Yes Yes Yes Yes Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes - No - Yes No Yes No Yes No - - - - 193 193 193 199 199 199 199 199 199 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 115 115 115 115 115 115 115 115 115 115 115 115 Standard List of models 109R0812L401 109R0812L4011 109R0812M401 109R0812M4011 109R0812S401 109R0812S4011 109R0824F401 109R0824F4011 109R0824G401 109R0824G4011 109R0824H401 109R0824H4011 109R0824L401 109R0824L4011 109R0824M401 109R0824M4011 109R0824S401 109R0824S4011 109R0848K401 109R0848K4011 109R0848S401 109R0848S4011 9A0612F401 9A0612F4011 9A0612G401 9A0612G4011 9A0612H401 9A0612H4011 9A0612M401 9A0612M4011 9A0612S401 9A0612S4011 9A0624F401 9A0624F4011 9A0624G401 9A0624G4011 9A0624H401 9A0624H4011 9A0624M401 9A0624M4011 9A0624S401 9A0624S4011 9A0812F401 9A0812F4011 9A0812G401 9A0812G4011 9A0812H401 9A0812H4011 9A0812L401 9A0812L4011 9A0812M401 9A0812M4011 9A0812S401 9A0812S4011 9A0824F401 9A0824F4011 9A0824G401 9A0824G4011 9A0824H401 9A0824H4011 9A0824L401 109R0812L402 109R0812L4021 109R0812M402 109R0812M4021 109R0812S402 109R0812S4021 109R0824F402 109R0824F4021 109R0824G402 109R0824G4021 109R0824H402 109R0824H4021 109R0824L402 109R0824L4021 109R0824M402 109R0824M4021 109R0824S402 109R0824S4021 109R0848K402 109R0848K4021 109R0848S402 109R0848S4021 9A0612F402 9A0612F4021 9A0612G402 9A0612G4021 9A0612H402 9A0612H4021 9A0612M402 9A0612M4021 9A0612S402 9A0612S4021 9A0624F402 9A0624F4021 9A0624G402 9A0624G4021 9A0624H402 9A0624H4021 9A0624M402 9A0624M4021 9A0624S402 9A0624S4021 9A0812F402 9A0812F4021 9A0812G402 9A0812G4021 9A0812H402 9A0812H4021 9A0812L402 9A0812L4021 9A0812M402 9A0812M4021 9A0812S402 9A0812S4021 9A0824F402 9A0824F4021 9A0824G402 9A0824G4021 9A0824H402 9A0824H4021 9A0824L402 With pulse sensor 109R0812L401 109R0812L4011 109R0812M401 109R0812M4011 109R0812S401 109R0812S4011 109R0824F401 109R0824F4011 109R0824G401 109R0824G4011 109R0824H401 109R0824H4011 109R0824L401 109R0824L4011 109R0824M401 109R0824M4011 109R0824S401 109R0824S4011 109R0848K401 109R0848K4011 109R0848S401 109R0848S4011 9A0612F401 9A0612F4011 9A0612G401 9A0612G4011 9A0612H401 9A0612H4011 9A0612M401 9A0612M4011 9A0612S401 9A0612S4011 9A0624F401 9A0624F4011 9A0624G401 9A0624G4011 9A0624H401 9A0624H4011 9A0624M401 9A0624M4011 9A0624S401 9A0624S4011 9A0812F401 9A0812F4011 9A0812G401 9A0812G4011 9A0812H401 9A0812H4011 9A0812L401 9A0812L4011 9A0812M401 9A0812M4011 9A0812S401 9A0812S4011 9A0824F401 9A0824F4011 9A0824G401 9A0824G4011 9A0824H401 9A0824H4011 9A0824L401 With lock sensor 109R0812L4D01 109R0812L4D011 109R0812M4D01 109R0812M4D011 109R0812S4D01 109R0812S4D011 109R0824F4D01 109R0824F4D011 109R0824G4D01 109R0824G4D011 109R0824H4D01 109R0824H4D011 109R0824L4D01 109R0824L4D011 109R0824M4D01 109R0824M4D011 109R0824S4D01 109R0824S4D011 109R0848K4D01 109R0848K4D011 109R0848S4D01 109R0848S4D011 9A0612F4D01 9A0612F4D011 9A0612G4D01 9A0612G4D011 9A0612H4D01 9A0612H4D011 9A0612M4D01 9A0612M4D011 9A0612S4D01 9A0612S4D011 9A0624F4D01 9A0624F4D011 9A0624G4D01 - 9A0624H4D01 9A0624H4D011 9A0624M4D01 9A0624M4D011 9A0624S4D01 9A0624S4D011 9A0812F4D01 9A0812F4D011 9A0812G4D01 9A0812G4D011 9A0812H4D01 9A0812H4D011 9A0812L4D01 9A0812L4D011 9A0812M4D01 9A0812M4D011 9A0812S4D01 9A0812S4D011 9A0824F4D01 9A0824F4D011 9A0824G4D01 9A0824G4D011 9A0824H4D01 9A0824H4D011 9A0824L4D01 With PWM control function and pulse sensor - - - - - - - - - - - - - - - - - - - - - - - - 9AH0612P4G03 - 9AH0612P4H05 - - - - - - - - - - - - - - - - - 9AH0812P4G04 9AH0812P4G011 9AH0812P4H04 - - - - - - - - - - - - - - UL CSA TUV cULcUL 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 118 118 118 118 118 118 118 118 118 118 118 118 118 118 118 118 118 118 118 Please contact your point of sale regarding low-speed sensors. 565 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9A0824L4011 9A0824M401 9A0824M4011 9A0824S401 9A0824S4011 9A0912F401 9A0912F4011 9A0912G401 9A0912G4011 9A0912H401 9A0912H4011 9A0912L401 9A0912L4011 9A0912M401 9A0912M4011 9A0912S401 9A0912S4011 9A0924F401 9A0924F4011 9A0924G401 9A0924G4011 9A0924H401 9A0924H4011 9A0924L401 9A0924L4011 9A0924M401 9A0924M4011 9A0924S401 9A0924S4011 9A0948S401 9A0948S4011 9B1TP24P0H001 9B1TP48P0G001 9B1TP48P0H001 9B1TS48P0G001 9B1TS48P0H001 9BD12FC6-1 9BD12HC6-1 9BD12SC6-1 9BD24FC6-1 9BD24HC6-1 9BD24SC6-1 9BFB12P2H003 9BFB24P2H003 9BMB12F201 9BMB12G201 9BMB12H201 9BMB12K201 9BMB12P2F01 9BMB12P2G01 9BMB12P2H01 9BMB12P2K01 9BMB12P2S01 9BMB12S201 9BMB24F201 9BMB24G201 9BMB24H201 9BMB24K201 9BMB24P2F01 9BMB24P2G01 9BMB24P2H01 9A0824L4021 9A0824M402 9A0824M4021 9A0824S402 9A0824S4021 9A0912F402 9A0912F4021 9A0912G402 9A0912G4021 9A0912H402 9A0912H4021 9A0912L402 9A0912L4021 9A0912M402 9A0912M4021 9A0912S402 9A0912S4021 9A0924F402 9A0924F4021 9A0924G402 9A0924G4021 9A0924H402 9A0924H4021 9A0924L402 9A0924L4021 9A0924M402 9A0924M4021 9A0924S402 9A0924S4021 9A0948S402 9A0948S4021 - - - - - 9BD12FA6-1 9BD12HA6-1 9BD12SA6-1 9BD24FA6-1 9BD24HA6-1 9BD24SA6-1 - - 9BMB12F202 9BMB12G202 9BMB12H202 9BMB12K202 9BMB12F202 9BMB12G202 9BMB12H202 9BMB12K202 9BMB12S202 9BMB12S202 9BMB24F202 9BMB24G202 9BMB24H202 9BMB24K202 9BMB24F202 9BMB24G202 9BMB24H202 With pulse sensor 9A0824L4011 9A0824M401 9A0824M4011 9A0824S401 9A0824S4011 9A0912F401 9A0912F4011 9A0912G401 9A0912G4011 9A0912H401 9A0912H4011 9A0912L401 9A0912L4011 9A0912M401 9A0912M4011 9A0912S401 9A0912S4011 9A0924F401 9A0924F4011 9A0924G401 9A0924G4011 9A0924H401 9A0924H4011 9A0924L401 9A0924L4011 9A0924M401 9A0924M4011 9A0924S401 9A0924S4011 9A0948S401 9A0948S4011 - - - - - 9BD12FC6-1 9BD12HC6-1 9BD12SC6-1 9BD24FC6-1 9BD24HC6-1 9BD24SC6-1 - - 9BMB12F201 9BMB12G201 9BMB12H201 9BMB12K201 9BMB12F201 9BMB12G201 9BMB12H201 9BMB12K201 9BMB12S201 9BMB12S201 9BMB24F201 9BMB24G201 9BMB24H201 9BMB24K201 9BMB24F201 9BMB24G201 9BMB24H201 With lock sensor 9A0824L4D011 9A0824M4D01 9A0824M4D011 9A0824S4D01 9A0824S4D011 9A0912F4D01 9A0912F4D011 9A0912G4D01 9A0912G4D011 9A0912H4D01 9A0912H4D011 9A0912L4D01 9A0912L4D011 9A0912M4D01 9A0912M4D011 9A0912S4D01 9A0912S4D011 9A0924F4D01 9A0924F4D011 9A0924G4D01 - 9A0924H4D01 9A0924H4D011 9A0924L4D01 9A0924L4D011 9A0924M4D01 9A0924M4D011 9A0924S4D01 9A0924S4D011 9A0948S4D01 - - - - - - 9BD12FD6-1 9BD12HD6-1 9BD12SD6-1 9BD24FD6-1 9BD24HD6-1 9BD24SD6-1 - - 9BMB12F2D01 9BMB12G2D01 9BMB12H2D01 - 9BMB12F2D01 9BMB12G2D01 9BMB12H2D01 - - - 9BMB24F2D01 9BMB24G2D01 9BMB24H2D01 - 9BMB24F2D01 9BMB24G2D01 9BMB24H2D01 Please contact your point of sale regarding low-speed sensors. 566 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor - - - - - - - 9AH0912P4G03 - 9AH0912P4H03 - - - - - - - - - - - - - - - - - - - - - 9B1TP24P0H001 9B1TP48P0G001 9B1TP48P0H001 9B1TS48P0G001 9B1TS48P0H001 - - 9BD12P6S01 - - 9BD24P6S06 9BFB12P2H003 9BFB24P2H003 9BMB12P2F01 9BMB12P2G01 9BMB12P2H01 9BMB12P2K01 9BMB12P2F01 9BMB12P2G01 9BMB12P2H01 9BMB12P2K01 9BMB12P2S01 9BMB12P2S01 9BMB24P2F01 9BMB24P2G01 9BMB24P2H01 9BMB24P2K01 9BMB24P2F01 9BMB24P2G01 9BMB24P2H01 UL CSA TUV cULcUL 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm o 270 x 99 mm o 270 x 99 mm o 270 x 99 mm o 270 x 119 mm o 270 x 119 mm 76 x 20 mm 76 x 20 mm 76 x 20 mm 76 x 20 mm 76 x 20 mm 76 x 20 mm 120 x 32 mm 120 x 32 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 118 118 118 118 118 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 448 448 448 451 451 456 456 456 456 456 456 469 469 462 462 462 462 462 462 462 462 462 462 462 462 462 462 462 462 462 Standard List of models 9BMB24P2K01 9BMB24P2S01 9BMB24S201 9BMC12P2G001 9BMC24P2G001 9CR0612P5G03 9CR0612P5H03 9CR1212P0G03 9CR5748P9G001 9CRA0312P4J03 9CRA0312P4K03 9CRA0412P4G03 9CRA0412P4J03 9CRA0412P4K03 9CRA0612P0G001 9CRA0612P0S001 9CRA0612P6G001 9CRA0612P6J001 9CRA0612P6K001 9CRA0812P8G001 9CRA0824P8G001 9CRA0848P8G001 9CRA0912P0G001 9CRA0948P0G601 9CRB0812P8G001 9CRD0412P5G03 9CRD0412P5H03 9CRD0412P5J03 9CRD0412P5M03 9CRE0412P5J03 9CRE0612P0G001 9CRE0812P8G001 9CRH0412P5J001 9CRL0612P0G001 9CRL0812P8G001 9CRLA0612P0G001 9CRV0412P5J201 9EC2024H001 9EC2048A001 9EC2048H001 9EC2048J001 9G0612G101 9G0612G1011 9G0612P4H001 9G0612P4H0011 9G0612P4S001 9G0612P4S0011 9G0612S101 9G0612S1011 9G0624G101 9G0624G1011 9G0624H101 9G0624H1011 9G0624P4H001 9G0624P4H0011 9G0624P4S001 9G0624P4S0011 9G0624S101 9G0624S1011 9G0648G101 9G0648G1011 9BMB24K202 9BMB24S202 9BMB24S202 9BMC12G2002 - 9CR0612G502 - 9CR1212G002 - - 9CRA0312K402 9CRA0412G402 9CRA0412J402 9CRA0412K402 - - - - - - - - - - - - - - - 9CRE0412J502 - - - - - - - 9EC2024H002 9EC2048A002 9EC2048H002 9EC2048J002 9G0612G102 9G0612G1021 9G0612H4002 9G0612H40021 9G0612S4002 9G0612S40021 9G0612S102 9G0612S1021 9G0624G102 9G0624G1021 9G0624H102 9G0624H1021 9G0624H4002 9G0624H40021 9G0624S4002 9G0624S40021 9G0624S102 9G0624S1021 9G0648G102 9G0648G1021 With pulse sensor 9BMB24K201 9BMB24S201 9BMB24S201 - - 9CR0612G501 9CR0612H501 9CR1212G001 - 9CRA0312J401 - - 9CRA0412J401 9CRA0412K401 - - - - - 9CRA0812G8001 - - - - - - - - - - - - - - - - - 9EC2024H001 9EC2048A001 9EC2048H001 9EC2048J001 9G0612G101 9G0612G1011 - 9G0612H40011 9G0612S4001 - 9G0612S101 9G0612S1011 9G0624G101 9G0624G1011 9G0624H101 9G0624H1011 9G0624H4001 - - - 9G0624S101 9G0624S1011 9G0648G101 9G0648G1011 With lock sensor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9EC2024H0D01 9EC2048A0D01 - - 9G0612G1D01 9G0612G1D011 9G0612H4D001 9G0612H4D0011 - - 9G0612S1D01 - 9G0624G1D01 9G0624G1D011 9G0624H1D01 - 9G0624H4D001 - 9G0624S4D001 - 9G0624S1D01 - 9G0648G1D01 - With PWM control function and pulse sensor 9BMB24P2K01 9BMB24P2S01 9BMB24P2S01 9BMC12P2G001 9BMC24P2G001 9CR0612P5G03 9CR0612P5H03 9CR1212P0G03 9CR5748P9G001 9CRA0312P4J03 9CRA0312P4K03 9CRA0412P4G03 9CRA0412P4J03 9CRA0412P4K03 9CRA0612P0G001 9CRA0612P0S001 9CRA0612P6G001 9CRA0612P6J001 9CRA0612P6K001 9CRA0812P8G001 9CRA0824P8G001 9CRA0848P8G001 9CRA0912P0G001 9CRA0948P0G601 9CRB0812P8G001 9CRD0412P5G03 9CRD0412P5H03 9CRD0412P5J03 9CRD0412P5M03 9CRE0412P5J03 9CRE0612P0G001 9CRE0812P8G001 9CRH0412P5J001 9CRL0612P0G001 9CRL0812P8G001 9CRLA0612P0G001 9CRV0412P5J201 - 9EC2048P0A01 - 9EC2048P0J01 9G0612P1G03 9G0612P1G011 9G0612P4H001 9G0612P4H0011 9G0612P4S001 9G0612P4S0011 - - 9G0624P1G03 9G0624P1G031 - - 9G0624P4H001 9G0624P4H0011 9G0624P4S001 9G0624P4S0011 - - 9G0648P1G01 9G0648P1G011 UL CSA TUV cULcUL 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 97 x 33 mm 60 x 60 x 51 mm 60 x 60 x 51 mm 120 x 120 x 76 mm o 172 x 150 x 102 mm 38 x 38 x 48 mm 38 x 38 x 48 mm 40 x 40 x 48 mm 40 x 40 x 48 mm 40 x 40 x 48 mm 60 x 60 x 76 mm 60 x 60 x 76 mm 60 x 60 x 56 mm 60 x 60 x 56 mm 60 x 60 x 56 mm 80 x 80 x 80 mm 80 x 80 x 80 mm 80 x 80 x 80 mm 92 x 92 x 76 mm 92 x 92 x 76 mm 80 x 80 x 80 mm 40 x 40 x 56 mm 40 x 40 x 56 mm 40 x 40 x 56 mm 40 x 40 x 56 mm 40 x 40 x 56 mm 60 x 60 x 76 mm 80 x 80 x 80 mm 40 x 40 x 56 mm 60 x 60 x 76 mm 80 x 80 x 80 mm 60 x 60 x 76 mm 40 x 40 x 56 mm o 200 x 70 mm o 200 x 70 mm o 200 x 70 mm o 200 x 70 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - No No No - No No No No - Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No - - 462 462 462 460 460 238 238 256 258 224 224 226 226 226 245 245 240 240 240 251 251 251 254 254 247 233 233 233 233 236 243 249 229 375 381 373 231 221 221 221 221 92 92 71 71 71 71 92 92 92 92 92 92 71 71 71 71 92 92 92 92 Please contact your point of sale regarding low-speed sensors. 567 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Models listed in the main section of this catalog Without sensor 9G0648P4S001 9G0648P4S0011 9G0648S101 9G0648S1011 9G0812G101 9G0812G1011 9G0812H101 9G0812H1011 9G0812K101 9G0812K1011 9G0824G101 9G0824G1011 9G0824H101 9G0824H1011 9G0848G101 9G0848G1011 9G0848H101 9G0848H1011 9G0912A201 9G0912A2011 9G0912G101 9G0912G1011 9G0912H101 9G0912H1011 9G0912H201 9G0912H2011 9G0912M201 9G0912M2011 9G0912S201 9G0912S2011 9G0924A201 9G0924A2011 9G0924G101 9G0924G1011 9G0924H101 9G0924H1011 9G0924H201 9G0924H2011 9G0924M201 9G0924M2011 9G0924S201 9G0924S2011 9G0948A201 9G0948A2011 9G0948G101 9G0948G1011 9G0948H101 9G0948H1011 9G0948H201 9G0948H2011 9G0948J101 9G0948J1011 9G0948M201 9G0948M2011 9G0948S201 9G0948S2011 9G1212A401 9G1212A4011 9G1212B401 9G1212B4011 9G1212E101 With pulse sensor With lock sensor - - - - - - 9G0648S102 9G0648S1021 9G0812G102 9G0812G1021 9G0812H102 9G0812H1021 9G0812K102 9G0812K1021 9G0824G102 9G0824G1021 9G0824H102 9G0824H1021 9G0848G102 9G0848G1021 9G0848H102 9G0848H1021 9G0912A202 9G0912A2021 9G0912G102 9G0912G1021 9G0912H102 9G0912H1021 9G0912H202 9G0912H2021 9G0912M202 9G0912M2021 9G0912S202 9G0912S2021 9G0924A202 9G0924A2021 9G0924G102 9G0924G1021 9G0924H102 9G0924H1021 9G0924H202 9G0924H2021 9G0924M202 9G0924M2021 9G0924S202 9G0924S2021 9G0948A202 9G0948A2021 9G0948G102 9G0948G1021 9G0948H102 - 9G0948H202 9G0948H2021 - - 9G0948M202 9G0948M2021 9G0948S202 9G0948S2021 9G1212A402 9G1212A4021 - - 9G1212E102 9G0648S101 9G0648S1011 9G0812G101 9G0812G1011 9G0812H101 9G0812H1011 9G0812K101 9G0812K1011 9G0824G101 9G0824G1011 9G0824H101 9G0824H1011 9G0848G101 9G0848G1011 9G0848H101 9G0848H1011 9G0912A201 9G0912A2011 9G0912G101 9G0912G1011 9G0912H101 9G0912H1011 9G0912H201 9G0912H2011 9G0912M201 9G0912M2011 9G0912S201 9G0912S2011 9G0924A201 9G0924A2011 9G0924G101 9G0924G1011 9G0924H101 9G0924H1011 9G0924H201 9G0924H2011 9G0924M201 9G0924M2011 9G0924S201 9G0924S2011 9G0948A201 9G0948A2011 9G0948G101 9G0948G1011 9G0948H101 9G0948H1011 9G0948H201 9G0948H2011 9G0948J101 9G0948J1011 9G0948M201 9G0948M2011 9G0948S201 9G0948S2011 9G1212A401 9G1212A4011 9G1212B401 9G1212B4011 9G1212E101 9G0648S1D01 - 9G0812G1D01 9G0812G1D011 9G0812H1D01 9G0812H1D011 9G0812K1D01 - 9G0824G1D01 9G0824G1D011 9G0824H1D01 9G0824H1D011 9G0848G1D01 9G0848G1D011 9G0848H1D01 - 9G0912A2D01 9G0912A2D011 9G0912G1D01 - 9G0912H1D01 9G0912H1D011 9G0912H2D01 9G0912H2D011 9G0912M2D01 9G0912M2D011 9G0912S2D01 9G0912S2D011 9G0924A2D01 9G0924A2D011 9G0924G1D01 9G0924G1D011 9G0924H1D01 9G0924H1D011 9G0924H2D01 9G0924H2D011 9G0924M2D01 9G0924M2D011 9G0924S2D01 9G0924S2D011 9G0948A2D01 9G0948A2D011 9G0948G1D01 - 9G0948H1D01 - 9G0948H2D01 9G0948H2D011 - - 9G0948M2D01 9G0948M2D011 9G0948S2D01 9G0948S2D011 9G1212A4D01 9G1212A4D011 - - 9G1212E1D01 Please contact your point of sale regarding low-speed sensors. 568 Frame size With PWM control function and pulse sensor 9G0648P4S001 9G0648P4S0011 - - 9G0812P1G04 9G0812P1G081 9G0812P1H03 9G0812P1H051 9G0812P1K08 9G0812P1K081 9G0824P1G04 - - - 9G0848P1G03 - 9G0848P1H04 - 9G0912P2A01 - 9G0912P1G03 9G0912P1G031 9G0912P1H05 - 9G0912P2H01 - - - 9G0912P2S01 - - - - - - - - - - - - - - - - - - - - - - 9G0948P1J031 - - - - - - - - - (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) UL CSA TUV cULcUL 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes - No - Yes - - 71 71 92 92 139 139 139 139 139 139 139 139 139 139 139 139 139 139 152 152 163 163 163 163 152 152 152 152 152 152 152 152 163 163 163 163 152 152 152 152 152 152 152 152 163 163 163 163 152 152 163 163 152 152 152 152 173 173 - 173 - 173 187 Standard List of models 9G1212E1011 9G1212E401 9G1212E4011 9G1212F101 9G1212F1011 9G1212F401 9G1212F4011 9G1212G101 9G1212G1011 9G1212G401 9G1212G4011 9G1212H101 9G1212H1011 9G1212H401 9G1212H4011 9G1212M101 9G1212M1011 9G1212M401 9G1212M4011 9G1224A401 9G1224A4011 9G1224E101 9G1224E1011 9G1224E401 9G1224E4011 9G1224F101 9G1224F1011 9G1224F401 9G1224F4011 9G1224G101 9G1224G1011 9G1224G401 9G1224G4011 9G1224H101 9G1224H1011 9G1224H401 9G1224H4011 9G1224M101 9G1224M1011 9G1224M401 9G1224M4011 9G1248A401 9G1248A4011 9G1248E101 9G1248E1011 9G1248E401 9G1248E4011 9G1248F101 9G1248F1011 9G1248F401 9G1248F4011 9G1248G101 9G1248G1011 9G1248G401 9G1248G4011 9G1248H101 9G1248H1011 9G1248H401 9G1248H4011 9G1248M101 9G1248M1011 9G1212E1021 9G1212E402 9G1212E4021 9G1212F102 9G1212F1021 9G1212F402 9G1212F4021 9G1212G102 9G1212G1021 9G1212G402 9G1212G4021 9G1212H102 9G1212H1021 9G1212H402 9G1212H4021 9G1212M102 9G1212M1021 9G1212M402 9G1212M4021 9G1224A402 9G1224A4021 9G1224E102 9G1224E1021 9G1224E402 9G1224E4021 9G1224F102 9G1224F1021 9G1224F402 9G1224F4021 9G1224G102 9G1224G1021 9G1224G402 9G1224G4021 9G1224H102 9G1224H1021 9G1224H402 9G1224H4021 9G1224M102 9G1224M1021 9G1224M402 9G1224M4021 9G1248A402 9G1248A4021 9G1248E102 9G1248E1021 9G1248E402 9G1248E4021 9G1248F102 9G1248F1021 9G1248F402 9G1248F4021 9G1248G102 9G1248G1021 9G1248G402 9G1248G4021 9G1248H102 9G1248H1021 9G1248H402 9G1248H4021 9G1248M102 9G1248M1021 With pulse sensor 9G1212E1011 9G1212E401 9G1212E4011 9G1212F101 9G1212F1011 9G1212F401 9G1212F4011 9G1212G101 9G1212G1011 9G1212G401 9G1212G4011 9G1212H101 9G1212H1011 9G1212H401 9G1212H4011 9G1212M101 9G1212M1011 9G1212M401 9G1212M4011 9G1224A401 9G1224A4011 9G1224E101 9G1224E1011 9G1224E401 9G1224E4011 9G1224F101 9G1224F1011 9G1224F401 9G1224F4011 9G1224G101 9G1224G1011 9G1224G401 9G1224G4011 9G1224H101 9G1224H1011 9G1224H401 9G1224H4011 9G1224M101 9G1224M1011 9G1224M401 9G1224M4011 9G1248A401 9G1248A4011 9G1248E101 9G1248E1011 9G1248E401 9G1248E4011 9G1248F101 9G1248F1011 9G1248F401 9G1248F4011 9G1248G101 9G1248G1011 9G1248G401 9G1248G4011 9G1248H101 9G1248H1011 9G1248H401 9G1248H4011 9G1248M101 9G1248M1011 With lock sensor 9G1212E1D011 9G1212E4D01 9G1212E4D011 9G1212F1D01 - 9G1212F4D01 9G1212F4D011 9G1212G1D01 9G1212G1D011 9G1212G4D01 9G1212G4D011 9G1212H1D01 9G1212H1D011 9G1212H4D01 9G1212H4D011 9G1212M1D01 9G1212M1D011 9G1212M4D01 9G1212M4D011 9G1224A4D01 9G1224A4D011 9G1224E1D01 9G1224E1D011 9G1224E4D01 9G1224E4D011 9G1224F1D01 - 9G1224F4D01 9G1224F4D011 9G1224G1D01 9G1224G1D011 9G1224G4D01 9G1224G4D011 9G1224H1D01 9G1224H1D011 9G1224H4D01 9G1224H4D011 9G1224M1D01 9G1224M1D011 9G1224M4D01 9G1224M4D011 9G1248A4D01 9G1248A4D011 9G1248E1D01 9G1248E1D011 9G1248E4D01 9G1248E4D011 9G1248F1D01 - 9G1248F4D01 9G1248F4D011 9G1248G1D01 9G1248G1D011 9G1248G4D01 9G1248G4D011 9G1248H1D01 9G1248H1D011 9G1248H4D01 9G1248H4D011 9G1248M1D01 9G1248M1D011 With PWM control function and pulse sensor - 9G1212P4E05 9G1212P4E041 - - - - 9G1212P1G04 9G1212P1G081 9G1212P4G03 9G1212P4G031 - - 9G1212P4H04 9G1212P4H091 - - - - - - - - 9G1224P4E01 - - - - - 9G1224P1G01 - - - - - - - - - - - - - - - 9G1248P4E05 - - - - - 9G1248P1G04 9G1248P1G041 9G1248P4G04 - - - - - - - UL CSA TUV cULcUL 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No 187 173 173 187 187 173 173 187 187 173 173 187 187 173 173 187 187 173 173 173 173 187 187 173 173 187 187 173 173 187 187 173 173 187 187 173 173 187 187 173 173 173 173 187 187 173 173 187 187 173 173 187 187 173 173 187 187 173 173 187 187 Please contact your point of sale regarding low-speed sensors. 569 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9G1248M401 9G1248M4011 9GA0312P3G001 9GA0312P3G0011 9GA0312P3J001 9GA0312P3J0011 9GA0312P3K001 9GA0312P3K0011 9GA0405P6F001 9GA0405P6H001 9GA0412G7001 9GA0412H7001 9GA0412P3G01 9GA0412P3G011 9GA0412P3H01 9GA0412P3H011 9GA0412P3J01 9GA0412P3J011 9GA0412P3K01 9GA0412P3K011 9GA0412P3M01 9GA0412P3M011 9GA0412P6F001 9GA0412P6G001 9GA0412P6H001 9GA0412P7G001 9GA0424P3G001 9GA0424P3G0011 9GA0424P3H001 9GA0424P3H0011 9GA0424P3J001 9GA0424P3J0011 9GA0424P3M001 9GA0424P3M0011 9GA0424P6F001 9GA0424P6G001 9GA0424P6H001 9GA0512P7A001 9GA0512P7G001 9GA0512P7H001 9GA0512P7M001 9GA0524P7A001 9GA0524P7G001 9GA0524P7H001 9GA0524P7M001 9GA0612G701 9GA0612G9001 9GA0612H6001 9GA0612H701 9GA0612H9001 9GA0612L701 9GA0612L9001 9GA0612M6001 9GA0612M701 9GA0612P1H03 9GA0612P1H031 9GA0612P1J03 9GA0612P1J031 9GA0612P1K03 9GA0612P1K031 9GA0612P1K60 9G1248M402 9G1248M4021 - - - - - - 9GA0405F6002 9GA0405H6002 9GA0412G7002 9GA0412H7002 9GA0412G302 9GA0412G3021 9GA0412H302 9GA0412H3021 9GA0412J302 9GA0412J3021 9GA0412K302 9GA0412K3021 9GA0412M302 9GA0412M3021 9GA0412F6002 9GA0412G6002 9GA0412H6002 9GA0412G7002 9GA0424G3002 9GA0424G30021 9GA0424H3002 9GA0424H30021 9GA0424J3002 9GA0424J30021 9GA0424M3002 9GA0424M30021 9GA0424F6002 9GA0424G6002 9GA0424H6002 9GA0512A7002 9GA0512G7002 9GA0512H7002 9GA0512M7002 9GA0524A7002 9GA0524G7002 9GA0524H7002 9GA0524M7002 9GA0612G702 9GA0612G9002 9GA0612H6002 9GA0612H702 9GA0612H9002 9GA0612L702 9GA0612L9002 9GA0612M6002 9GA0612M702 9GA0612H102 9GA0612H1021 9GA0612J102 9GA0612J1021 9GA0612K102 9GA0612K1021 - With pulse sensor 9G1248M401 9G1248M4011 9GA0312G3001 - 9GA0312J3001 - 9GA0312K3001 - 9GA0405F6001 9GA0405H6001 9GA0412G7001 9GA0412H7001 9GA0412G301 9GA0412G3011 9GA0412H301 9GA0412H3011 9GA0412J301 9GA0412J3011 9GA0412K301 9GA0412K3011 9GA0412M301 9GA0412M3011 9GA0412F6001 9GA0412G6001 9GA0412H6001 9GA0412G7001 9GA0424G3001 9GA0424G30011 9GA0424H3001 9GA0424H30011 9GA0424J3001 9GA0424J30011 9GA0424M3001 9GA0424M30011 9GA0424F6001 9GA0424G6001 9GA0424H6001 9GA0512A7001 9GA0512G7001 9GA0512H7001 9GA0512M7001 9GA0524A7001 9GA0524G7001 9GA0524H7001 9GA0524M7001 9GA0612G701 9GA0612G9001 9GA0612H6001 9GA0612H701 9GA0612H9001 9GA0612L701 9GA0612L9001 9GA0612M6001 9GA0612M701 9GA0612H101 9GA0612H1011 9GA0612J101 9GA0612J1011 9GA0612K101 9GA0612K1011 - With lock sensor 9G1248M4D01 9G1248M4D011 - - - - - 9GA0312K3D0011 - - 9GA0412G7D001 9GA0412H7D001 - - 9GA0412H3D01 9GA0412H3D011 9GA0412J3D01 - 9GA0412K3D01 - 9GA0412M3D01 - - - - 9GA0412G7D001 9GA0424G3D001 - 9GA0424H3D001 - 9GA0424J3D001 - - 9GA0424M3D001 9GA0424F6D001 9GA0424G6D001 9GA0424H6D001 - - 9GA0512H7D001 - 9GA0524A7D001 9GA0524G7D001 - - 9GA0612G7D01 9GA0612G9D001 9GA0612H6D001 9GA0612H7D01 9GA0612H9D001 9GA0612L7D01 9GA0612L9D001 9GA0612M6D001 - - - 9GA0612J1D01 - 9GA0612K1D01 9GA0612K1D011 - Please contact your point of sale regarding low-speed sensors. 570 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor - - 9GA0312P3G001 9GA0312P3G0011 9GA0312P3J001 9GA0312P3J0011 9GA0312P3K001 9GA0312P3K0011 9GA0405P6F001 9GA0405P6H001 9GA0412P7G001 - 9GA0412P3G01 9GA0412P3G011 9GA0412P3H01 9GA0412P3H011 9GA0412P3J01 9GA0412P3J011 9GA0412P3K01 9GA0412P3K011 9GA0412P3M01 9GA0412P3M011 9GA0412P6F001 9GA0412P6G001 9GA0412P6H001 9GA0412P7G001 9GA0424P3G001 9GA0424P3G0011 9GA0424P3H001 9GA0424P3H0011 9GA0424P3J001 9GA0424P3J0011 9GA0424P3M001 9GA0424P3M0011 9GA0424P6F001 9GA0424P6G001 9GA0424P6H001 9GA0512P7A001 9GA0512P7G001 9GA0512P7H001 9GA0512P7M001 9GA0524P7A001 9GA0524P7G001 9GA0524P7H001 9GA0524P7M001 9GA0612P7G01 9GA0612P9G001 - 9GA0612P7H01 - - - - - 9GA0612P1H03 9GA0612P1H031 9GA0612P1J03 9GA0612P1J031 9GA0612P1K03 9GA0612P1K031 9GA0612P1K60 UL CSA TUV cULcUL 120 x 120 x 25 mm 120 x 120 x 25 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 40 x 40 x 15 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 52 x 52 x 15 mm 60 x 60 x 15 mm 60 x 60 x 10 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 10 mm 60 x 60 x 15 mm 60 x 60 x 10 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes No Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes No Yes 173 173 14 14 14 14 14 14 26 26 21 21 38 38 38 38 38 38 38 38 38 38 26 26 26 21 38 38 38 38 38 38 38 38 26 26 26 50 50 50 50 50 50 50 50 59 57 65 59 57 59 57 65 59 85 85 85 85 85 85 85 Standard List of models 9GA0612P1K601 9GA0612P6G001 9GA0612P6S001 9GA0612P7G01 9GA0612P7H01 9GA0624H6001 9GA0624M6001 9GA0624M701 9GA0624P1J03 9GA0624P1J031 9GA0624P1K03 9GA0624P1K031 9GA0624P6G001 9GA0624P6S001 9GA0624P7G01 9GA0712P1G001 9GA0712P1G0011 9GA0712P1H001 9GA0712P1H0011 9GA0812A2001 9GA0812A20011 9GA0812B2001 9GA0812B20011 9GA0812H7001 9GA0812L2001 9GA0812L20011 9GA0812P1G61 9GA0812P1G611 9GA0812P1H61 9GA0812P1H611 9GA0812P1S61 9GA0812P1S611 9GA0812P2H001 9GA0812P2H0011 9GA0812P2M001 9GA0812P2M0011 9GA0812P2S001 9GA0812P2S0011 9GA0812P4G001 9GA0812P4G0011 9GA0812P4H001 9GA0812P4H0011 9GA0812P4J001 9GA0812P4J0011 9GA0812P6G001 9GA0812P6M001 9GA0812P7G001 9GA0812P7S001 9GA0824A2001 9GA0824A20011 9GA0824B2001 9GA0824B20011 9GA0824H7001 9GA0824L2001 9GA0824L20011 9GA0824P1H61 9GA0824P1H611 9GA0824P1S61 9GA0824P1S611 9GA0824P2S001 9GA0824P2S0011 - 9GA0612G6002 9GA0612S6002 9GA0612G702 9GA0612H702 9GA0624H6002 9GA0624M6002 9GA0624M702 9GA0624J102 9GA0624J1021 - - 9GA0624G6002 9GA0624S6002 9GA0624G702 - - - - 9GA0812A2002 9GA0812A20021 9GA0812B2002 9GA0812B20021 - 9GA0812L2002 9GA0812L20021 - - 9GA0812H162 9GA0812H1621 9GA0812S162 9GA0812S1621 - - - - - - 9GA0812G4002 9GA0812G40021 9GA0812H4002 9GA0812H40021 9GA0812J4002 9GA0812J40021 9GA0812G6002 9GA0812M6002 - - 9GA0824A2002 9GA0824A20021 9GA0824B2002 9GA0824B20021 9GA0824H7002 9GA0824L2002 9GA0824L20021 9GA0824H162 9GA0824H1621 9GA0824S162 9GA0824S1621 9GA0824S2002 - With pulse sensor - 9GA0612G6001 9GA0612S6001 9GA0612G701 9GA0612H701 9GA0624H6001 9GA0624M6001 9GA0624M701 9GA0624J101 9GA0624J1011 - - 9GA0624G6001 - - - - - - 9GA0812A2001 9GA0812A20011 9GA0812B2001 9GA0812B20011 9GA0812H7001 9GA0812L2001 9GA0812L20011 - - 9GA0812H161 9GA0812H1611 9GA0812S161 9GA0812S1611 - - - - 9GA0812S2001 - 9GA0812G4001 9GA0812G40011 9GA0812H4001 9GA0812H40011 9GA0812J4001 9GA0812J40011 9GA0812G6001 9GA0812M6001 - - 9GA0824A2001 9GA0824A20011 9GA0824B2001 9GA0824B20011 9GA0824H7001 9GA0824L2001 9GA0824L20011 9GA0824H161 9GA0824H1611 9GA0824S161 9GA0824S1611 - - With lock sensor - - - 9GA0612G7D01 9GA0612H7D01 9GA0624H6D001 9GA0624M6D001 - - - 9GA0624K1D01 - - - - - - - - 9GA0812A2D001 9GA0812A2D0011 9GA0812B2D001 9GA0812B2D0011 9GA0812H7D001 9GA0812L2D001 9GA0812L2D0011 - - 9GA0812H1D61 - 9GA0812S1D61 - - - - - - - - - 9GA0812H4D001 - 9GA0812J4D001 - - - - - 9GA0824A2D001 9GA0824A2D0011 9GA0824B2D001 9GA0824B2D0011 9GA0824H7D001 9GA0824L2D001 9GA0824L2D0011 9GA0824H1D61 - - - - - With PWM control function and pulse sensor 9GA0612P1K601 9GA0612P6G001 9GA0612P6S001 9GA0612P7G01 9GA0612P7H01 - - - 9GA0624P1J03 9GA0624P1J031 9GA0624P1K03 9GA0624P1K031 9GA0624P6G001 9GA0624P6S001 9GA0624P7G01 9GA0712P1G001 9GA0712P1G0011 9GA0712P1H001 9GA0712P1H0011 - - - - - - - 9GA0812P1G61 9GA0812P1G611 9GA0812P1H61 9GA0812P1H611 9GA0812P1S61 9GA0812P1S611 9GA0812P2H001 9GA0812P2H0011 9GA0812P2M001 9GA0812P2M0011 9GA0812P2S001 9GA0812P2S0011 9GA0812P4G001 9GA0812P4G0011 9GA0812P4H001 9GA0812P4H0011 9GA0812P4J001 9GA0812P4J0011 9GA0812P6G001 9GA0812P6M001 9GA0812P7G001 9GA0812P7S001 - - - - - - - 9GA0824P1H61 9GA0824P1H611 9GA0824P1S61 9GA0824P1S611 9GA0824P2S001 9GA0824P2S0011 UL CSA TUV cULcUL 60 x 60 x 38 mm 60 x 60 x 20 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 15 mm 60 x 60 x 20 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 20 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 70 x 70 x 38 mm 70 x 70 x 38 mm 70 x 70 x 38 mm 70 x 70 x 38 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 15 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 20 mm 80 x 80 x 20 mm 80 x 80 x 15 mm 80 x 80 x 15 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 15 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 32 mm 80 x 80 x 32 mm No Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes Yes Yes Yes No Yes No Yes No Yes No Yes Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes No Yes No Yes Yes No Yes No Yes No Yes No 85 65 65 59 59 65 65 59 85 85 85 85 65 65 59 95 95 95 95 123 123 123 123 97 123 123 132 132 132 132 132 132 123 123 123 123 123 123 108 108 108 108 108 108 102 102 97 97 123 123 123 123 97 123 123 132 132 132 132 123 123 Please contact your point of sale regarding low-speed sensors. 571 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9GA0824P4G001 9GA0824P4G0011 9GA0824P4H001 9GA0824P4H0011 9GA0824P4J001 9GA0824P4J0011 9GA0824P6G001 9GA0824P6M001 9GA0824P7G001 9GA0824P7S001 9GA0848P1S61 9GA0848P1S611 9GA0848P2S001 9GA0848P2S0011 9GA0912F401 9GA0912F4011 9GA0912H401 9GA0912H4011 9GA0912L401 9GA0912L4011 9GA0912M401 9GA0912M4011 9GA0912P1H03 9GA0912P1H031 9GA0912P4G03 9GA0912P4G031 9GA0912P4J03 9GA0912P4J031 9GA0912P4S03 9GA0912P4S031 9GA0912W401 9GA0912W4011 9GA0924F401 9GA0924F4011 9GA0924H401 9GA0924H4011 9GA0924L401 9GA0924L4011 9GA0924M401 9GA0924M4011 9GA0924P1H01 9GA0924P1H011 9GA0924P4G03 9GA0924P4G031 9GA0924P4J03 9GA0924P4J031 9GA0924P4S03 9GA0924P4S031 9GA0924W401 9GA0924W4011 9GA0948P1H03 9GA0948P1H031 9GA1212G4001 9GA1212G40011 9GA1212P4G001 9GA1212P4G0011 9GA1212P4S001 9GA1212P4S0011 9GA1212S4001 9GA1212S40011 9GA1224G4001 9GA0824G4002 9GA0824G40021 9GA0824H4002 9GA0824H40021 9GA0824J4002 9GA0824J40021 9GA0824G6002 9GA0824M6002 - - - - - - 9GA0912F402 9GA0912F4021 9GA0912H402 9GA0912H4021 9GA0912L402 9GA0912L4021 9GA0912M402 9GA0912M4021 9GA0912H102 9GA0912H1021 9GA0912G402 9GA0912G4021 9GA0912J402 9GA0912J4021 9GA0912S402 9GA0912S4021 9GA0912W402 9GA0912W4021 9GA0924F402 9GA0924F4021 9GA0924H402 9GA0924H4021 9GA0924L402 9GA0924L4021 9GA0924M402 9GA0924M4021 9GA0924H102 - 9GA0924G402 9GA0924G4021 9GA0924J402 9GA0924J4021 9GA0924S402 9GA0924S4021 9GA0924W402 9GA0924W4021 9GA0948H102 - - - - - - - - - 9GA1224G4002 With pulse sensor 9GA0824G4001 9GA0824G40011 9GA0824H4001 9GA0824H40011 9GA0824J4001 9GA0824J40011 9GA0824G6001 9GA0824M6001 - - - - - - 9GA0912F401 9GA0912F4011 9GA0912H401 9GA0912H4011 9GA0912L401 9GA0912L4011 9GA0912M401 9GA0912M4011 9GA0912H101 9GA0912H1011 9GA0912G401 9GA0912G4011 9GA0912J401 9GA0912J4011 9GA0912S401 9GA0912S4011 9GA0912W401 9GA0912W4011 9GA0924F401 9GA0924F4011 9GA0924H401 9GA0924H4011 9GA0924L401 9GA0924L4011 9GA0924M401 9GA0924M4011 9GA0924H101 9GA0924H1011 9GA0924G401 9GA0924G4011 9GA0924J401 9GA0924J4011 9GA0924S401 9GA0924S4011 9GA0924W401 9GA0924W4011 9GA0948H101 - 9GA1212G4001 9GA1212G40011 9GA1212G4001 9GA1212G40011 9GA1212S4001 9GA1212S40011 9GA1212S4001 9GA1212S40011 9GA1224G4001 With lock sensor - - 9GA0824H4D001 - 9GA0824J4D001 9GA0824J4D0011 - - 9GA0824G7D001 - - - - - 9GA0912F4D01 9GA0912F4D011 9GA0912H4D01 9GA0912H4D011 9GA0912L4D01 9GA0912L4D011 9GA0912M4D01 9GA0912M4D011 9GA0912H1D01 - 9GA0912G4D01 - 9GA0912J4D01 9GA0912J4D011 9GA0912S4D01 9GA0912S4D011 9GA0912W4D01 9GA0912W4D011 9GA0924F4D01 9GA0924F4D011 9GA0924H4D01 9GA0924H4D011 9GA0924L4D01 9GA0924L4D011 9GA0924M4D01 9GA0924M4D011 9GA0924H1D01 9GA0924H1D011 9GA0924G4D01 - 9GA0924J4D01 - 9GA0924S4D01 - 9GA0924W4D01 9GA0924W4D011 - - - - - - - - - - 9GA1224G4D001 Please contact your point of sale regarding low-speed sensors. 572 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor 9GA0824P4G001 9GA0824P4G0011 9GA0824P4H001 9GA0824P4H0011 9GA0824P4J001 9GA0824P4J0011 9GA0824P6G001 9GA0824P6M001 9GA0824P7G001 9GA0824P7S001 9GA0848P1S61 9GA0848P1S611 9GA0848P2S001 9GA0848P2S0011 - - - - - - - - 9GA0912P1H03 9GA0912P1H031 9GA0912P4G03 9GA0912P4G031 9GA0912P4J03 9GA0912P4J031 9GA0912P4S03 9GA0912P4S031 - - - - - - - - - - 9GA0924P1H01 9GA0924P1H011 9GA0924P4G03 9GA0924P4G031 9GA0924P4J03 9GA0924P4J031 9GA0924P4S03 9GA0924P4S031 - - 9GA0948P1H03 9GA0948P1H031 9GA1212P4G001 9GA1212P4G0011 9GA1212P4G001 9GA1212P4G0011 9GA1212P4S001 9GA1212P4S0011 9GA1212P4S001 9GA1212P4S0011 9GA1224P4G001 UL CSA TUV cULcUL 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 20 mm 80 x 80 x 20 mm 80 x 80 x 15 mm 80 x 80 x 15 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 32 mm 80 x 80 x 32 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm Yes No Yes No Yes No Yes Yes Yes Yes Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 108 108 108 108 108 108 102 102 97 97 132 132 123 123 142 142 142 142 142 142 142 142 157 157 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 157 157 142 142 142 142 142 142 142 142 157 157 166 166 166 166 166 166 166 166 166 Standard List of models 9GA1224G40011 9GA1224P4G001 9GA1224P4G0011 9GA1224P4S001 9GA1224P4S0011 9GA1224S4001 9GA1224S40011 9GA1248G4001 9GA1248G40011 9GA1248P4G001 9GA1248P4G0011 9GA1248P4S001 9GA1248P4S0011 9GA1248S4001 9GA1248S40011 9GAX0412P3K001 9GAX0412P3K0011 9GAX0412P3K003 9GAX0412P3K0031 9GAX0412P3S001 9GAX0412P3S0011 9GAX0412P3S003 9GAX0412P3S0031 9GE0412P3G03 9GE0412P3J03 9GE0412P3K03 9GL1212E101 9GL1212F101 9GL1212G101 9GL1212H101 9GL1212M101 9GL1224E101 9GL1224F101 9GL1224G101 9GL1224H101 9GL1224M101 9GL1248E101 9GL1248F101 9GL1248G101 9GL1248H101 9GL1248M101 9GP1224P1G001 9GP1248P1G001 9GP5724P5H001 9GP5748P5G001 9GT0412P3J001 9GT0424P3J001 9GT0612P4G001 9GT0624P4G001 9GT0812P4S001 9GT0824P4S001 9GT0912P1M001 9GT0912P4J001 9GT0924P1M001 9GT0924P4J001 9GT1212P1S001 9GT1224P1S001 9GV0312E301 9GV0312E3011 9GV0312G301 9GV0312G3011 - 9GA1224G4002 - - - 9GA1224S4002 - - - - - - - - - - - - - - - - - - 9GE0412J302 - 9GL1212E102 9GL1212F102 9GL1212G102 9GL1212H102 9GL1212M102 9GL1224E102 9GL1224F102 9GL1224G102 9GL1224H102 9GL1224M102 9GL1248E102 9GL1248F102 9GL1248G102 9GL1248H102 9GL1248M102 9GP1224G1002 - - - 9GT0412J3002 9GT0424J3002 9GT0612G4002 9GT0624G4002 9GT0812S4002 9GT0824S4002 9GT0912M1002 9GT0912J4002 9GT0924M1002 9GT0924J4002 - 9GT1224S1002 9GV0312E302 - 9GV0312G302 9GV0312G3021 With pulse sensor 9GA1224G40011 9GA1224G4001 9GA1224G40011 9GA1224S4001 9GA1224S40011 9GA1224S4001 9GA1224S40011 9GA1248G4001 9GA1248G40011 9GA1248G4001 9GA1248G40011 9GA1248S4001 9GA1248S40011 9GA1248S4001 9GA1248S40011 - - - - - - - - - 9GE0412J301 9GE0412K301 9GL1212E101 9GL1212F101 9GL1212G101 9GL1212H101 9GL1212M101 9GL1224E101 9GL1224F101 9GL1224G101 9GL1224H101 9GL1224M101 9GL1248E101 9GL1248F101 9GL1248G101 9GL1248H101 9GL1248M101 - - - - 9GT0412J3001 9GT0424J3001 9GT0612G4001 9GT0624G4001 9GT0812S4001 9GT0824S4001 9GT0912M1001 9GT0912J4001 - 9GT0924J4001 - - 9GV0312E301 9GV0312E3011 9GV0312G301 9GV0312G3011 With lock sensor - 9GA1224G4D001 - - - - - - - - - - - - - - - - - - - - - 9GE0412G3D01 9GE0412J3D01 9GE0412K3D01 9GL1212E1D01 9GL1212F1D01 9GL1212G1D01 9GL1212H1D01 9GL1212M1D01 9GL1224E1D01 9GL1224F1D01 9GL1224G1D01 9GL1224H1D01 9GL1224M1D01 9GL1248E1D01 9GL1248F1D01 9GL1248G1D01 9GL1248H1D01 9GL1248M1D01 - - - - 9GT0412J3D001 9GT0424J3D001 9GT0612G4D001 - 9GT0812S4D001 - 9GT0912M1D001 9GT0912J4D001 9GT0924M1D001 - - 9GT1224S1D001 9GV0312E3D01 9GV0312E3D011 9GV0312G3D01 - With PWM control function and pulse sensor 9GA1224P4G0011 9GA1224P4G001 9GA1224P4G0011 9GA1224P4S001 9GA1224P4S0011 9GA1224P4S001 9GA1224P4S0011 9GA1248P4G001 9GA1248P4G0011 9GA1248P4G001 9GA1248P4G0011 9GA1248P4S001 9GA1248P4S0011 9GA1248P4S001 9GA1248P4S0011 9GAX0412P3K001 9GAX0412P3K0011 9GAX0412P3K003 9GAX0412P3K0031 9GAX0412P3S001 9GAX0412P3S0011 9GAX0412P3S003 9GAX0412P3S0031 9GE0412P3G03 9GE0412P3J03 9GE0412P3K03 - - - - - - - - - - - - - - - 9GP1224P1G001 9GP1248P1G001 9GP5724P5H001 9GP5748P5G001 9GT0412P3J001 9GT0424P3J001 9GT0612P4G001 9GT0624P4G001 9GT0812P4S001 9GT0824P4S001 9GT0912P1M001 9GT0912P4J001 9GT0924P1M001 9GT0924P4J001 9GT1212P1S001 9GT1224P1S001 - - 9GV0312P3G03 - UL CSA TUV cULcUL 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No Yes No Yes No 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 35 35 35 35 35 35 35 35 42 42 42 395 395 395 395 395 395 395 395 395 395 395 395 395 395 395 426 426 428 428 412 412 414 414 416 416 420 418 420 418 422 422 17 17 17 17 Please contact your point of sale regarding low-speed sensors. 573 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9GV0312H301 9GV0312H3011 9GV0312J301 9GV0312J3011 9GV0312K301 9GV0312K3011 9GV0412C301 9GV0412C3011 9GV0412G301 9GV0412G3011 9GV0412H301 9GV0412H3011 9GV0412J301 9GV0412J3011 9GV0412K301 9GV0412K3011 9GV0612P1G03 9GV0612P1G031 9GV0612P1H03 9GV0612P1H031 9GV0612P1L01 9GV0612P1L011 9GV0612P1M03 9GV0612P1M031 9GV0624P1G03 9GV0624P1G031 9GV0624P1M03 9GV0624P1M031 9GV0648P1H03 9GV0648P1H031 9GV0812P1F03 9GV0812P1F031 9GV0812P1G03 9GV0812P1G031 9GV0812P1H03 9GV0812P1H031 9GV0812P1M03 9GV0812P1M031 9GV0812P4J03 9GV0812P4J031 9GV0812P4K03 9GV0812P4K031 9GV0824P1G03 9GV0824P1G031 9GV0824P4K01 9GV0824P4K011 9GV0848P1G03 9GV0848P1G031 9GV0848P4K03 9GV0848P4K031 9GV0912P1F03 9GV0912P1F031 9GV0912P1G03 9GV0912P1G031 9GV0912P1H03 9GV0912P1H031 9GV0948P1F03 9GV0948P1F031 9GV0948P1H03 9GV0948P1H031 9GV1212P1G01 9GV0312H302 - 9GV0312J302 9GV0312J3021 - - - - 9GV0412G302 9GV0412G3021 - - 9GV0412J302 9GV0412J3021 9GV0412K302 - 9GV0612G102 9GV0612G1021 9GV0612H102 9GV0612H1021 9GV0612L102 9GV0612L1021 9GV0612M102 - 9GV0624G102 9GV0624G1021 9GV0624M102 - - - - - 9GV0812G102 9GV0812G1021 9GV0812H102 9GV0812H1021 - - 9GV0812J402 9GV0812J4021 - 9GV0812K4021 9GV0824G102 - 9GV0824K402 - 9GV0848G102 - - - - - - - 9GV0912H102 - - - 9GV0948H102 9GV0948H1021 - With pulse sensor 9GV0312H301 9GV0312H3011 9GV0312J301 9GV0312J3011 9GV0312K301 9GV0312K3011 9GV0412C301 9GV0412C3011 9GV0412G301 9GV0412G3011 9GV0412H301 9GV0412H3011 9GV0412J301 9GV0412J3011 9GV0412K301 9GV0412K3011 9GV0612G101 9GV0612G1011 9GV0612H101 9GV0612H1011 - 9GV0612L1011 9GV0612M101 9GV0612M1011 - - 9GV0624M101 - - - - - 9GV0812G101 9GV0812G1011 9GV0812H101 9GV0812H1011 - - 9GV0812J401 9GV0812J4011 9GV0812K401 9GV0812K4011 9GV0824G101 - 9GV0824K401 - 9GV0848G101 9GV0848G1011 9GV0848K401 - - - - - 9GV0912H101 - - - 9GV0948H101 - - With lock sensor 9GV0312H3D01 - 9GV0312J3D01 - 9GV0312K3D01 9GV0312K3D011 9GV0412C3D01 9GV0412C3D011 9GV0412G3D01 9GV0412G3D011 9GV0412H3D01 - 9GV0412J3D01 9GV0412J3D011 9GV0412K3D01 - 9GV0612G1D01 9GV0612G1D011 9GV0612H1D01 9GV0612H1D011 - 9GV0612L1D011 9GV0612M1D01 9GV0612M1D011 9GV0624G1D01 - - - - - - - - - - - - - - - 9GV0812K4D01 9GV0812K4D011 - - - - - - - - - - - - 9GV0912H1D01 - - - - - - Please contact your point of sale regarding low-speed sensors. 574 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor - - 9GV0312P3J03 9GV0312P3J031 9GV0312P3K01 - - - 9GV0412P3G03 9GV0412P3G031 9GV0412P3H01 - 9GV0412P3J03 9GV0412P3J031 9GV0412P3K03 - 9GV0612P1G03 9GV0612P1G031 9GV0612P1H03 9GV0612P1H031 9GV0612P1L01 9GV0612P1L011 9GV0612P1M03 9GV0612P1M031 9GV0624P1G03 9GV0624P1G031 9GV0624P1M03 9GV0624P1M031 9GV0648P1H03 9GV0648P1H031 9GV0812P1F03 9GV0812P1F031 9GV0812P1G03 9GV0812P1G031 9GV0812P1H03 9GV0812P1H031 9GV0812P1M03 9GV0812P1M031 9GV0812P4J03 9GV0812P4J031 9GV0812P4K03 9GV0812P4K031 9GV0824P1G03 9GV0824P1G031 9GV0824P4K01 9GV0824P4K011 9GV0848P1G03 9GV0848P1G031 9GV0848P4K03 9GV0848P4K031 9GV0912P1F03 9GV0912P1F031 9GV0912P1G03 9GV0912P1G031 9GV0912P1H03 9GV0912P1H031 9GV0948P1F03 9GV0948P1F031 9GV0948P1H03 9GV0948P1H031 9GV1212P1G01 UL CSA TUV cULcUL 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 38 x 38 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 120 x 120 x 38 mm Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 17 17 17 17 17 17 45 45 45 45 45 45 45 45 45 45 88 88 88 88 88 88 88 88 88 88 88 88 88 88 136 136 136 136 136 136 136 136 112 112 112 112 136 136 112 112 136 136 112 112 160 160 160 160 160 160 160 160 160 160 182 Standard List of models 9GV1212P1G011 9GV1212P1J01 9GV1212P1J011 9GV1212P4G01 9GV1212P4G011 9GV1224P1H01 9GV1224P1H011 9GV1224P1J01 9GV1224P1J011 9GV1224P4G01 9GV1224P4G011 9GV1248P1J01 9GV1248P1J011 9GV1248P4G01 9GV1248P4G011 9GV1248P4H01 9GV1248P4H011 9GV1248P4J01 9GV1248P4J011 9GV1412P1G001 9GV1412P1H001 9GV1412P1S001 9GV1424P1G001 9GV1424P1H001 9GV1424P1S001 9GV1448P1G001 9GV1448P1H001 9GV1448P1S001 9GV1512H501 9GV1512H5011 9GV1512M501 9GV1512M5011 9GV1524M501 9GV1524M5011 9GV2048P0G201 9GV3612G301 9GV3612J301 9GV5724H501 9GV5748H501 9GX3612P3K001 9HV0412P3K001 9HV0612P1J001 9HV0612P1J0011 9HV0812P1G601 9HV0812P1G6011 9HV0824P1G003 9HV0824P1G0011 9HV0848P1G001 9HV0848P1G0011 9HV0912P1G001 9HV0912P1G0011 9HV0948P1G001 9HV0948P1G0011 9HV1224P1A001 9HV1248P1G001 9HV1248P1H001 9HV5724P5H001 9HV5748P5G001 9HVA0812P1G001 9HVA0812P1G0011 9L0412H301 - 9GV1212J102 9GV1212J1021 9GV1212G402 9GV1212G4021 9GV1224H102 9GV1224H1021 9GV1224J102 9GV1224J1021 9GV1224G402 9GV1224G4021 9GV1248J102 9GV1248J1021 9GV1248G402 - 9GV1248H402 - - - - - - - - - - - - 9GV1512H502 9GV1512H5021 9GV1512M502 9GV1512M5021 9GV1524M502 - 9GV2048G0202 9GV3612G302 9GV3612J302 9GV5724H502 9GV5748H502 9GX3612K3002 - - - 9HV0812G1002 9HV0812G10021 - - 9HV0848G1002 9HV0848G10021 - - - - - 9HV1248G1002 9HV1248H1002 9HV5724H5002 - - - 9L0412H302 With pulse sensor 9GV1212G1011 9GV1212J101 9GV1212J1011 9GV1212G401 9GV1212G4011 9GV1224H101 9GV1224H1011 9GV1224J101 9GV1224J1011 9GV1224G401 - 9GV1248J101 9GV1248J1011 9GV1248G4011 9GV1248G4011 9GV1248H401 - - - - - - - - - - - - 9GV1512H501 9GV1512H5011 9GV1512M501 9GV1512M5011 9GV1524M501 9GV1524M5011 - 9GV3612G301 9GV3612J301 9GV5724H501 9GV5748H501 - - - - 9HV0812G1001 9HV0812G10011 - - 9HV0848G1001 9HV0848G10011 - - - - - 9HV1248G1001 9HV1248H1001 9HV5724H5001 - - - 9L0412H301 With lock sensor 9GV1212G1D011 9GV1212J1D01 - - - 9GV1224H1D01 9GV1224H1D011 9GV1224J1D01 9GV1224J1D011 9GV1224G4D01 - 9GV1248J1D01 - - - 9GV1248H4D01 - - - - - - - - - - - - - - - - 9GV1524M5D01 - - 9GV3612G3D01 9GV3612J3D01 - - - - - - - - 9HV0824G1D001 - 9HV0848G1D001 - - - - - 9HV1224A1D001 - - 9HV5724H5D001 - - - 9L0412H3D01 With PWM control function and pulse sensor 9GV1212P1G011 9GV1212P1J01 9GV1212P1J011 9GV1212P4G01 9GV1212P4G011 9GV1224P1H01 9GV1224P1H011 9GV1224P1J01 9GV1224P1J011 9GV1224P4G01 9GV1224P4G011 9GV1248P1J01 9GV1248P1J011 9GV1248P4G01 9GV1248P4G011 9GV1248P4H01 9GV1248P4H011 9GV1248P4J01 9GV1248P4J011 9GV1412P1G001 9GV1412P1H001 9GV1412P1S001 9GV1424P1G001 9GV1424P1H001 9GV1424P1S001 9GV1448P1G001 9GV1448P1H001 9GV1448P1S001 9GV1512P5H03 - 9GV1512P5M03 9GV1512P5M011 - - 9GV2048P0G201 9GV3612P3G03 9GV3612P3J03 9GV5724P5H03 9GV5748P5H01 9GX3612P3K001 9HV0412P3K001 9HV0612P1J001 9HV0612P1J0011 9HV0812P1G601 9HV0812P1G6011 9HV0824P1G003 9HV0824P1G0011 9HV0848P1G001 9HV0848P1G0011 9HV0912P1G001 9HV0912P1G0011 9HV0948P1G001 9HV0948P1G0011 9HV1224P1A001 9HV1248P1G001 9HV1248P1H001 9HV5724P5H001 9HV5748P5G001 9HVA0812P1G001 9HVA0812P1G0011 - UL CSA TUV cULcUL 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 150 x 150 x 50 mm 150 x 150 x 50 mm 150 x 150 x 50 mm 150 x 150 x 50 mm 150 x 150 x 50 mm 150 x 150 x 50 mm o 200 x 70 mm 36 x 36 x 28 mm 36 x 36 x 28 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm 36 x 36 x 28 mm 40 x 40 x 28 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 40 x 40 x 28 mm No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No No No No No No No No No No Yes No Yes No Yes No No Yes Yes No No Yes No Yes No Yes No Yes No Yes No Yes No Yes No No No No No No Yes No No 182 182 182 170 170 182 182 182 182 170 170 182 182 170 170 170 170 170 170 195 195 195 195 195 195 195 195 195 201 201 201 201 201 201 219 12 12 211 211 12 33 83 83 129 129 129 129 129 129 155 155 155 155 179 179 179 206 206 127 127 366 Please contact your point of sale regarding low-speed sensors. 575 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9L0412J301 9L0412M301 9LG0612P4H001 9LG0612P4J001 9LG0612P4M001 9LG0612P4S001 9LG0624P4H001 9LG0624P4J001 9LG0624P4M001 9LG0624P4S001 9LG0648P4H001 9LG0648P4J001 9LG0648P4M001 9LG0648P4S001 9LG0812F4001 9LG0812L4001 9LG0812M4001 9LG0812P4G001 9LG0812P4H001 9LG0812P4J001 9LG0812S4001 9LG0824F4001 9LG0824L4001 9LG0824M4001 9LG0824P4G001 9LG0824P4H001 9LG0824P4J001 9LG0824S4001 9LG0912F4001 9LG0912L4001 9LG0912M4001 9LG0912P1F001 9LG0912P1H001 9LG0912P4G001 9LG0912P4H001 9LG0912P4J001 9LG0912P4S001 9LG0924F4001 9LG0924L4001 9LG0924M4001 9LG0924P1F001 9LG0924P1H001 9LG0924P4G001 9LG0924P4H001 9LG0924P4J001 9LG0924P4S001 9LG1212F1001 9LG1212M1001 9LG1212P1G001 9LG1212P1H001 9LG1212P1S001 9LG1224A1001 9LG1224F1001 9LG1224M1001 9LG1224P1G001 9LG1224P1H001 9LG1224P1S001 9LG1248F1001 9LG1248M1001 9LG1248P1G001 9LG1248P1H001 9L0412J302 9L0412M302 9LG0612H4002 - - - - - - - - - - - 9LG0812F4002 9LG0812L4002 9LG0812M4002 - 9LG0812H4002 9LG0812J4002 9LG0812S4001 9LG0824F4002 9LG0824L4002 9LG0824M4002 9LG0824G4002 9LG0824H4002 - 9LG0824S4002 9LG0912F4002 9LG0912L4002 9LG0912M4002 - - 9LG0912G4002 9LG0912H4002 - 9LG0912S4002 9LG0924F4002 9LG0924L4002 9LG0924M4002 - - - 9LG0924H4002 - - 9LG1212F1002 9LG1212M1002 - - - 9LG1224A1002 9LG1224F1002 9LG1224M1002 - - - 9LG1248F1002 9LG1248M1002 9LG1248G1002 - With pulse sensor 9L0412J301 9L0412M301 9LG0612H4001 - 9LG0624M4001 9LG0612S4001 - - 9LG0624M4001 - - - - - 9LG0812F4001 9LG0812L4001 9LG0812M4001 9LG0812G4001 9LG0812H4001 - 9LG0812S4002 9LG0824F4001 9LG0824L4001 9LG0824M4001 - 9LG0824H4001 - 9LG0824S4001 9LG0912F4001 9LG0912L4001 9LG0912M4001 - - - 9LG0912H4001 - 9LG0912S4001 9LG0924F4001 9LG0924L4001 9LG0924M4001 - - - 9LG0924H4001 - - 9LG1212F1001 9LG1212M1001 - - - 9LG1224A1001 9LG1224F1001 9LG1224M1001 - 9LG1224H1001 9LG1224S1001 9LG1248F1001 9LG1248M1001 - - With lock sensor 9L0412J3D01 9L0412M3D01 9LG0612H4D001 9LG0612J4D001 9LG0612M4D001 - - - - - - - - - 9LG0812F4D001 9LG0812L4D001 9LG0812M4D001 9LG0812G4D001 9LG0812H4D001 9LG0812J4D001 9LG0812S4D001 9LG0824F4D001 9LG0824L4D001 9LG0824M4D001 9LG0824G4D001 9LG0824H4D001 9LG0824J4D001 9LG0824S4D001 9LG0912F4D001 9LG0912L4D001 9LG0912M4D001 - - - 9LG0912H4D001 - 9LG0912S4D001 9LG0924F4D001 9LG0924L4D001 9LG0924M4D001 - - - 9LG0924H4D001 9LG0924J4D001 9LG0924S4D001 9LG1212F1D001 9LG1212M1D001 - - - 9LG1224A1D001 9LG1224F1D001 9LG1224M1D001 9LG1224G1D001 9LG1224H1D001 9LG1224S1D001 9LG1248F1D001 9LG1248M1D001 - - Please contact your point of sale regarding low-speed sensors. 576 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor 9L0412P3J01 - 9LG0612P4H001 9LG0612P4J001 9LG0612P4M001 9LG0612P4S001 9LG0624P4H001 9LG0624P4J001 9LG0624P4M001 9LG0624P4S001 9LG0648P4H001 9LG0648P4J001 9LG0648P4M001 9LG0648P4S001 - - - 9LG0812P4G001 9LG0812P4H001 9LG0812P4J001 - - - - 9LG0824P4G001 9LG0824P4H001 9LG0824P4J001 - - - - 9LG0912P1F001 9LG0912P1H001 9LG0912P4G001 9LG0912P4H001 9LG0912P4J001 9LG0912P4S001 - - - 9LG0924P1F001 9LG0924P1H001 9LG0924P4G001 9LG0924P4H001 9LG0924P4J001 9LG0924P4S001 - - 9LG1212P1G001 9LG1212P1H001 9LG1212P1S001 - - - 9LG1224P1G001 9LG1224P1H001 9LG1224P1S001 - - 9LG1248P1G001 9LG1248P1H001 UL CSA TUV cULcUL 40 x 40 x 28 mm 40 x 40 x 28 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No 366 366 368 368 368 368 368 368 368 368 368 368 368 368 377 377 377 377 377 377 377 377 377 377 377 377 377 377 383 383 383 387 387 383 383 383 383 383 383 383 387 387 383 383 383 383 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 Standard List of models 9LG1248P1S001 9LG1412A5001 9LG1412H5001 9LG1412L1001 9LG1412M5001 9LG1412P1A001 9LG1412P1H001 9LG1412P1M001 9LG1412P5G001 9LG1412P5S001 9LG1424A5001 9LG1424H5001 9LG1424L1001 9LG1424M5001 9LG1424P1A001 9LG1424P1H001 9LG1424P1M001 9LG1424P5G001 9LG1424P5S001 9LG1448A5001 9LG1448H5001 9LG1448L1001 9LG1448M5001 9LG1448P1A001 9LG1448P1H001 9LG1448P1M001 9LG1448P5G001 9LG1448P5S001 9RF0912P1H001 9RF0924P1H001 9RF1312P3H001 9RF1324P3H001 9S0612F401 9S0612F4011 9S0612H401 9S0612H4011 9S0612M401 9S0612M4011 9S0612S401 9S0612S4011 9S0812F401 9S0812F4011 9S0812H401 9S0812H4011 9S0812L401 9S0812L4011 9S0812M401 9S0812M4011 9S0824L401 9S0824L4011 9S0824M401 9S0824M4011 9S0912F401 9S0912F4011 9S0912L401 9S0912L4011 9S0912M401 9S0912M4011 9S0924F401 9S0924F4011 9S0924L401 - 9LG1412A5002 9LG1412H5002 9LG1412L1002 9LG1412M5002 - - 9LG1412M1002 - - 9LG1424A5002 9LG1424H5002 9LG1424L1002 9LG1424M5002 - - 9LG1424M1002 - 9LG1424S5002 9LG1448A5002 9LG1448H5002 9LG1448L1002 9LG1448M5002 - - 9LG1448M1002 - - - - - - 9S0612F402 9S0612F4021 9S0612H402 9S0612H4021 9S0612M402 9S0612M4021 9S0612S402 - 9S0812F402 9S0812F4021 9S0812H402 - 9S0812L402 9S0812L4021 9S0812M402 9S0812M4021 9S0824L402 9S0824L4021 9S0824M402 9S0824M4021 9S0912F402 9S0912F4021 9S0912L402 9S0912L4021 9S0912M402 9S0912M4021 9S0924F402 9S0924F4021 9S0924L402 With pulse sensor - 9LG1412A5001 9LG1412H5001 9LG1412L1001 9LG1412M5001 - - 9LG1412M1001 - - 9LG1424A5001 9LG1424H5001 9LG1424L1001 9LG1424M5001 - - 9LG1424M1001 - 9LG1424S5001 9LG1448A5001 9LG1448H5001 9LG1448L1001 9LG1448M5001 - - 9LG1448M1001 - - - - - - 9S0612F401 9S0612F4011 9S0612H401 9S0612H4011 9S0612M401 9S0612M4011 9S0612S401 9S0612S4011 9S0812F401 9S0812F4011 9S0812H401 9S0812H4011 9S0812L401 9S0812L4011 9S0812M401 9S0812M4011 9S0824L401 9S0824L4011 9S0824M401 9S0824M4011 9S0912F401 9S0912F4011 9S0912L401 9S0912L4011 9S0912M401 9S0912M4011 9S0924F401 9S0924F4011 9S0924L401 With lock sensor - 9LG1412A5D001 9LG1412H5D001 - 9LG1412M5D001 - - 9LG1412M1D001 - - 9LG1424A5D001 9LG1424H5D001 9LG1424L1D001 9LG1424M5D001 - - 9LG1424M1D001 - 9LG1424S5D001 9LG1448A5D001 9LG1448H5D001 9LG1448L1D001 9LG1448M5D001 - - 9LG1448M1D001 - - - - - - 9S0612F4D01 9S0612F4D011 9S0612H4D01 9S0612H4D011 9S0612M4D01 9S0612M4D011 9S0612S4D01 - 9S0812F4D01 9S0812F4D011 9S0812H4D01 9S0812H4D011 9S0812L4D01 9S0812L4D011 9S0812M4D01 9S0812M4D011 9S0824L4D01 9S0824L4D011 9S0824M4D01 9S0824M4D011 9S0912F4D01 9S0912F4D011 9S0912L4D01 9S0912L4D011 9S0912M4D01 9S0912M4D011 9S0924F4D01 - 9S0924L4D01 With PWM control function and pulse sensor 9LG1248P1S001 - - - - 9LG1412P1A001 9LG1412P1H001 9LG1412P1M001 9LG1412P5G001 9LG1412P5S001 - - - - 9LG1424P1A001 9LG1424P1H001 9LG1424P1M001 9LG1424P5G001 9LG1424P5S001 - - - - 9LG1448P1A001 9LG1448P1H001 9LG1448P1M001 9LG1448P5G001 9LG1448P5S001 9RF0912P1H001 9RF0924P1H001 9RF1312P3H001 9RF1324P3H001 9S0612P4F01 9S0612P4F011 9S0612P4H01 9S0612P4H011 9S0612P4M01 - 9S0612P4S01 - 9S0812P4F01 9S0812P4F011 - - - - 9S0812P4M01 9S0812P4M011 - - - - 9S0912P4F01 9S0912P4F011 - - 9S0912P4M01 9S0912P4M011 - - - UL CSA TUV cULcUL 120 x 120 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm o 92 x 38 mm o 92 x 38 mm o 136 x 28 mm o 136 x 28 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes - - 390 403 403 398 403 398 398 398 403 403 403 403 398 403 398 398 398 403 403 403 403 398 403 398 398 398 403 403 262 262 264 264 81 81 81 81 81 81 81 81 121 121 121 121 121 121 121 121 121 121 121 121 150 150 150 150 150 150 150 150 150 Please contact your point of sale regarding low-speed sensors. 577 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9S0924L4011 9S0924M401 9S0924M4011 9S1212F401 9S1212F4011 9S1212H401 9S1212H4011 9S1212L401 9S1212L4011 9S1212M401 9S1212M4011 9S1224M401 9S1224M4011 9SG1212G101 9SG1224G101 9SG1224H101 9SG1248G101 9SG5724P5H61 9SG5748P5G01 9SG5748P5H01 9TG24P0G01 9TG24P0S01 9TG48P0G01 9TGA24P0H001 9TGA48P0G001 9TJ24P0H61 9TJ48P0H01 9TM24P4H01 9TM48P4H01 9TN24P1H01 9TN48P1H01 9TP24P0H001 9TP48P0G001 9TP48P0H001 9TS48P0G001 9TS48P0H001 9W1TG48P0H61 9W1TJ24P0H61 9W1TJ48P0H61 9W1TM48P4G01 9W1TM48P4H01 9W1TN48P1H01 9W2TGA48P0G001 9W2TP24P0H001 9W2TP48P0S001 9W2TS48P0S001 9WE1724K501 9WE5724K501 9WE5748K501 9WF0424F601 9WF0424H601 9WF0424H701 9WF0624H401 9WF0624H601 9WF0624H701 9WF0824S401 9WF0924H201 9WF0924H2011 9WF0924H401 9WF0924H4011 9WF0924S201 9S0924L4021 9S0924M402 9S0924M4021 9S1212F402 9S1212F4021 9S1212H402 9S1212H4021 9S1212L402 9S1212L4021 9S1212M402 9S1212M4021 9S1224M402 9S1224M4021 9SG1212G102 9SG1224G102 9SG1224H102 9SG1248G102 9SG5724H562 - - 9TG24G002 9TG24S002 - - - - - - - - - - 9TP48G0002 - - - - - - - - - - - - - 9WE1724K502 9WE5724K502 9WE5748K502 9WF0424F602 9WF0424H602 9WF0424H702 9WF0624H402 - 9WF0624H702 9WF0824S402 9WF0924H202 - 9WF0924H402 - 9WF0924S202 With pulse sensor 9S0924L4011 9S0924M401 9S0924M4011 9S1212F401 9S1212F4011 9S1212H401 9S1212H4011 9S1212L401 9S1212L4011 9S1212M401 9S1212M4011 9S1224M401 9S1224M4011 9SG1212G101 9SG1224G101 9SG1224H101 9SG1248G101 - - - 9TG24G001 9TG24S001 - - - - - - - - - - - - - - - - - - - - - - - - 9WE1724K501 9WE5724K501 9WE5748K501 9WF0424F601 9WF0424H601 9WF0424H701 9WF0624H401 9WF0624H601 9WF0624H701 9WF0824S401 9WF0924H201 9WF0924H2011 9WF0924H401 9WF0924H4011 9WF0924S201 With lock sensor - 9S0924M4D01 - 9S1212F4D01 9S1212F4D011 9S1212H4D01 - 9S1212L4D01 9S1212L4D011 9S1212M4D01 9S1212M4D011 9S1224M4D01 9S1224M4D011 9SG1212G1D01 9SG1224G1D01 9SG1224H1D01 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9WE5748K5D01 9WF0424F6D01 9WF0424H6D01 9WF0424H7D01 9WF0624H4D01 9WF0624H6D01 9WF0624H7D01 9WF0824S4D01 9WF0924H2D01 - 9WF0924H4D01 9WF0924H4D011 9WF0924S2D01 Please contact your point of sale regarding low-speed sensors. 578 Frame size With PWM control function and pulse sensor - - - 9S1212P4F01 9S1212P4F011 9S1212P4H01 9S1212P4H011 - 9S1212P4L011 9S1212P4M01 9S1212P4M011 - - 9SG1212P1G01 9SG1224P1G01 - 9SG1248P1G01 9SG5724P5H61 9SG5748P5G01 9SG5748P5H01 9TG24P0G01 9TG24P0S01 9TG48P0G01 9TGA24P0H001 9TGA48P0G001 9TJ24P0H61 9TJ48P0H01 9TM24P4H01 9TM48P4H01 9TN24P1H01 9TN48P1H01 9TP24P0H001 9TP48P0G001 9TP48P0H001 9TS48P0G001 9TS48P0H001 9W1TG48P0H61 9W1TJ24P0H61 9W1TJ48P0H61 9W1TM48P4G01 9W1TM48P4H01 9W1TN48P1H01 9W2TGA48P0G001 9W2TP24P0H001 9W2TP48P0S001 9W2TS48P0S001 - - 9WE5748P5K01 - - - - - - - - - - - - (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) UL CSA TUV cULcUL 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm o 175 x 69 mm o 175 x 69 mm o 175 x 69 mm o 175 x 69 mm o 175 x 69 mm o 133 x 91 mm o 133 x 91 mm o 100 x 25 mm o 100 x 25 mm o 150 x 35 mm o 150 x 35 mm o 221 x 71 mm o 221 x 71 mm o 221 x 71 mm o 225 x 99 mm o 225 x 99 mm o 175 x 69 mm o 133 x 91 mm o 133 x 91 mm o 100 x 25 mm o 100 x 25 mm o 150 x 35 mm o 175 x 69 mm o 221 x 71 mm o 221 x 71 mm o 225 x 99 mm o 172 x 51 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 40 x 40 x 15 mm 60 x 60 x 25 mm 60 x 60 x 20 mm 60 x 60 x 15 mm 80 x 80 x 25 mm 92 x 92 x 32 mm 92 x 92 x 32 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 32 mm No Yes No Yes No Yes No Yes No Yes No Yes No No No No - No No No No - - - - - - - - - - - - - - - - - - - - - - - - - - No No No Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes - - 150 150 150 177 177 177 177 177 177 177 177 177 177 185 185 185 185 208 208 208 440 440 440 438 438 434 434 432 432 436 436 443 443 443 446 446 338 332 332 330 330 334 336 340 340 342 326 324 324 348 348 346 354 352 350 356 360 360 358 358 360 Standard List of models 9WF0924S2011 9WF1224H101 9WG1212E101-E 9WG1212F101-E 9WG1212G101-E 9WG1212H101-E 9WG1212M101-E 9WG1224E101-E 9WG1224F101-E 9WG1224G101-E 9WG1224H101-E 9WG1224M101-E 9WG1248E101-E 9WG1248F101-E 9WG1248G101-E 9WG1248H101-E 9WG1248M101-E 9WG5748P5G001 9WG5748P5H001 9WL0412P3G001 9WL0412P3J001 9WL0424P3G001 9WL0424P3J001 9WL0612P4H001 9WL0612P4J001 9WL0612P4S001 9WL0624P4H001 9WL0624P4J001 9WL0624P4S001 9WL0812L4001 9WL0812P4G001 9WL0812P4H001 9WL0812P4J001 9WL0824F4001 9WL0824P4G001 9WL0824P4H001 9WL0824P4J001 9WL0912M4001 9WL0912P1F001 9WL0912P1H001 9WL0912P4G001 9WL0912P4H001 9WL0912P4J001 9WL0912P4S001 9WL0924F4001 9WL0924M4001 9WL0924P1F001 9WL0924P1H001 9WL0924P4H001 9WL0924P4J001 9WL0924P4S001 9WL0948P1F601 9WL0948P1H601 9WL1412P1A001 9WL1412P1H001 9WL1412P1M001 9WL1412A5001 9WL1412H5001 9WL1412P5G001 9WL1412P5S001 9WL1424P1A001 - 9WF1224H102 9WG1212E102-E 9WG1212F102-E 9WG1212G102-E 9WG1212H102-E 9WG1212M102-E 9WG1224E102-E 9WG1224F102-E 9WG1224G102-E 9WG1224H102-E 9WG1224M102-E 9WG1248E102-E 9WG1248F102-E 9WG1248G102-E 9WG1248H102-E 9WG1248M102-E 9WG5748G5002 9WG5748H5002 9WL0412G3002 9WL0412J3002 9WL0424G3002 9WL0424J3002 - 9WL0612J4002 9WL0612S4002 - - - 9WL0812L4002 - 9WL0812H4002 - 9WL0824F4002 - 9WL0824H4002 - 9WL0912M4002 - - - 9WL0912H4002 9WL0912J4002 - 9WL0924F4002 9WL0924M4002 - - 9WL0924H4002 - - - - - - 9WL1412M1002 9WL1412A5002 9WL1412H5002 - - - With pulse sensor 9WF0924S2011 9WF1224H101 9WG1212E101-E 9WG1212F101-E 9WG1212G101-E 9WG1212H101-E 9WG1212M101-E 9WG1224E101-E 9WG1224F101-E 9WG1224G101-E 9WG1224H101-E 9WG1224M101-E 9WG1248E101-E 9WG1248F101-E 9WG1248G101-E 9WG1248H101-E 9WG1248M101-E - 9WG5748H5001 9WL0412G3001 9WL0412J3001 9WL0424G3001 9WL0424J3001 - - - 9WL0624H4001 - 9WL0624S4002 9WL0812L4001 - 9WL0812H4001 - 9WL0824F4001 - 9WL0824H4001 - 9WL0912M4001 - - - 9WL0912H4001 - - 9WL0924F4001 9WL0924M4001 - - 9WL0924H4001 - - - - - - 9WL1412M1001 9WL1412A5001 9WL1412H5001 - - - With lock sensor - 9WF1224H1D01 9WG1212E1D01-E 9WG1212F1D01-E 9WG1212G1D01-E 9WG1212H1D01-E 9WG1212M1D01-E 9WG1224E1D01-E 9WG1224F1D01-E 9WG1224G1D01-E 9WG1224H1D01-E 9WG1224M1D01-E 9WG1248E1D01-E 9WG1248F1D01-E 9WG1248G1D01-E 9WG1248H1D01-E 9WG1248M1D01-E - 9WG5748H5D001 - - - - - 9WL0612J4D001 9WL0612S4D001 - - - - 9WL0812G4D001 9WL0812H4D001 - - - 9WL0824H4D001 - - - - - 9WL0912H4D001 - - - 9WL0924M4D001 - - 9WL0924H4D001 - - - - - - 9WL1412M1D001 9WL1412A5D001 - - - - With PWM control function and pulse sensor - - - - - - - - - - - - - - - - - 9WG5748P5G001 9WG5748P5H001 9WL0412P3G001 9WL0412P3J001 9WL0424P3G001 9WL0424P3J001 9WL0612P4H001 9WL0612P4J001 9WL0612P4S001 9WL0624P4H001 9WL0624P4J001 9WL0624P4S001 - 9WL0812P4G001 9WL0812P4H001 9WL0812P4J001 - 9WL0824P4G001 9WL0824P4H001 9WL0824P4J001 - 9WL0912P1F001 9WL0912P1H001 9WL0912P4G001 9WL0912P4H001 9WL0912P4J001 9WL0912P4S001 - - 9WL0924P1F001 9WL0924P1H001 9WL0924P4H001 9WL0924P4J001 9WL0924P4S001 9WL0948P1F601 9WL0948P1H601 9WL1412P1A001 9WL1412P1H001 9WL1412P1M001 - - 9WL1412P5G001 9WL1412P5S001 9WL1424P1A001 UL CSA TUV cULcUL 92 x 92 x 32 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm o 172 x 150 x 51 mm o 172 x 150 x 51 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 40 x 40 x 28 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 38 mm No Yes No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No 360 362 307 307 307 307 307 307 307 307 307 307 307 307 307 307 307 322 322 270 270 270 270 273 273 273 273 273 273 279 279 279 279 279 279 279 279 289 299 299 289 289 289 289 289 289 299 299 289 289 289 299 299 313 313 313 318 318 318 318 313 Please contact your point of sale regarding low-speed sensors. 579 Index by Model No. Without sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Standard List of models Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) Without sensor 9WL1424P1H001 9WL1424P1M001 9WL1424H5001 9WL1424M5001 9WL1424P5G001 9WL1424P5S001 9WL1448H5001 9WL1448L1001 9WL1448P1A001 9WL1448P1H001 9WL1448P1M001 9WL1448P5G001 9WL1448P5S001 9WP0412F6001 9WP0412H6001 9WP0612D401 9WP0612D4011 9WP0612G401 9WP0612G4011 9WP0612H401 9WP0612H4011 9WP0624G401 9WP0624G4011 9WP0624H401 9WP0624H4011 9WP0624J401 9WP0624J4011 9WP0648H401 9WP0648H4011 9WP0812G401 9WP0812G4011 9WP0812H401 9WP0812H4011 9WP0824H401 9WP0824H4011 9WP0824S401 9WP0824S4011 9WP0848S401 9WP0848S4011 9WP0912F401 9WP0912F4011 9WP0912S401 9WP0912S4011 9WP0924B401 9WP0924B4011 9WP0924F401 9WP0924F4011 9WP0924G401 9WP0924G4011 9WP0924H401 9WP0924H4011 9WP0924S401 9WP0924S4011 9WP1212H101 9WP1212H1011 9WP1212L101 9WP1212L1011 9WP1212M101 9WP1212M1011 9WP1224H101 9WP1224H1011 - 9WL1424M1002 9WL1424H5002 9WL1424M5002 - - 9WL1448H5002 9WL1448L1002 - - 9WL1448M1002 - - 9WP0412F6002 9WP0412H6002 9WP0612D402 - 9WP0612G402 9WP0612G4021 9WP0612H402 9WP0612H4021 9WP0624G402 - 9WP0624H402 9WP0624H4021 9WP0624J402 - 9WP0648H402 9WP0648H4021 9WP0812G402 9WP0812G4021 9WP0812H402 9WP0812H4021 9WP0824H402 9WP0824H4021 9WP0824S402 9WP0824S4021 9WP0848S402 9WP0848S4021 9WP0912F402 - 9WP0912S402 - 9WP0924B402 9WP0924B4021 9WP0924F402 9WP0924F4021 9WP0924G402 - 9WP0924H402 - 9WP0924S402 - 9WP1212H102 9WP1212H1021 - - 9WP1212M102 9WP1212M1021 9WP1224H102 9WP1224H1021 With pulse sensor - 9WL1424M1001 9WL1424H5001 9WL1424M5001 - - 9WL1448H5001 9WL1448L1001 - - 9WL1448M1001 - - 9WP0412F6001 9WP0412H6001 9WP0612D401 9WP0612D4011 9WP0612G401 9WP0612G4011 9WP0612H401 9WP0612H4011 9WP0624G401 9WP0624G4011 9WP0624H401 9WP0624H4011 9WP0624J401 9WP0624J4011 9WP0648H401 9WP0648H4011 9WP0812G401 9WP0812G4011 9WP0812H401 9WP0812H4011 9WP0824H401 9WP0824H4011 9WP0824S401 9WP0824S4011 9WP0848S401 9WP0848S4011 9WP0912F401 9WP0912F4011 9WP0912S401 9WP0912S4011 9WP0924B401 9WP0924B4011 9WP0924F401 9WP0924F4011 9WP0924G401 9WP0924G4011 9WP0924H401 9WP0924H4011 9WP0924S401 9WP0924S4011 9WP1212H101 9WP1212H1011 9WP1212L101 9WP1212L1011 9WP1212M101 9WP1212M1011 9WP1224H101 9WP1224H1011 With lock sensor - 9WL1424M1D001 9WL1424H5D001 9WL1424M5D001 - - 9WL1448H5D001 - - - 9WL1448M1D001 - - 9WP0412F6D001 - 9WP0612D4D01 9WP0612D4D011 9WP0612G4D01 - 9WP0612H4D01 9WP0612H4D011 9WP0624G4D01 - 9WP0624H4D01 9WP0624H4D011 - - 9WP0648H4D01 9WP0648H4D011 9WP0812G4D01 9WP0812G4D011 9WP0812H4D01 9WP0812H4D011 9WP0824H4D01 9WP0824H4D011 9WP0824S4D01 - 9WP0848S4D01 9WP0848S4D011 9WP0912F4D01 9WP0912F4D011 9WP0912S4D01 - 9WP0924B4D01 9WP0924B4D011 9WP0924F4D01 9WP0924F4D011 9WP0924G4D01 - 9WP0924H4D01 - 9WP0924S4D01 - 9WP1212H1D01 9WP1212H1D011 - - - - 9WP1224H1D01 9WP1224H1D011 Please contact your point of sale regarding low-speed sensors. 580 Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) With PWM control function and pulse sensor 9WL1424P1H001 9WL1424P1M001 - - 9WL1424P5G001 9WL1424P5S001 - - 9WL1448P1A001 9WL1448P1H001 9WL1448P1M001 9WL1448P5G001 9WL1448P5S001 - - - - 9WP0612P4G01 - - - - - - - - - - - 9WP0812P4G01 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - UL CSA TUV cULcUL 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 38 mm 140 x 140 x 51 mm 140 x 140 x 51 mm 40 x 40 x 20 mm 40 x 40 x 20 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm No No No No No No No No No No No No No Yes Yes Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No 313 313 318 318 318 318 318 313 313 313 313 318 318 268 268 276 276 276 276 276 276 276 276 276 276 276 276 276 276 283 283 283 283 283 283 283 283 283 283 293 293 293 293 293 293 293 293 293 293 293 293 293 293 310 310 310 310 310 310 310 310 Standard List of models Without sensor 9WP1224M102 9WP1224M1021 9WP1248H102 9WP1248H1021 9WP1248M102 9WP1248M1021 9WS0812F402 9WS0812F4021 9WS0812H402 9WS0812H4021 9WS0812M402 9WS0812M4021 9WS0824F402 9WS0824F4021 9WS0824H402 9WS0824H4021 9WS0824M402 9WS0824M4021 9WS0912F402 9WS0912H402 9WS0912L402 9WS0912M402 9WS0924F402 9WS0924H402 9WS0924L402 9WS0924M402 - - - - 9WV0924H1002 - 9WV1212J1002 9WV1224H102 9WV1224J1002 9WV1248J1002 9WP1224M101 9WP1224M1011 9WP1248H101 9WP1248H1011 9WP1248M101 9WP1248M1011 9WS0812F401 9WS0812F4011 9WS0812H401 9WS0812H4011 9WS0812M401 9WS0812M4011 9WS0824F401 9WS0824F4011 9WS0824H401 9WS0824H4011 9WS0824M401 9WS0824M4011 9WS0912F401 9WS0912H401 9WS0912L401 9WS0912M401 9WS0924F401 9WS0924H401 9WS0924L401 9WS0924M401 9WV0812M1001 - - - - - - 9WV1224H101 9WV1224J1001 9WV1248J1001 With lock sensor - - 9WP1248H1D01 9WP1248H1D011 9WP1248M1D01 9WP1248M1D011 9WS0812F4D01 - - - 9WS0812M4D01 - - - 9WS0824H4D01 - 9WS0824M4D01 - 9WS0912F4D01 - - - - 9WS0924H4D01 - 9WS0924M4D01 9WV0812M1D001 - - - 9WV1212J1D001 9WV1224H1D001 - 9WV1248J1D001 With PWM control function and pulse sensor - - - - - - - - - - - - - - - - - - - - - - - - - - 9WV0812P1M001 9WV0812P1M0011 9WV0848P1H001 9WV0848P1H0011 9WV0924P1H001 9WV0948P1H001 9WV1212P1J001 9WV1224P1H001 9WV1224P1J601 9WV1248P1J001 UL CSA TUV cULcUL 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes Yes No No No No 310 310 310 310 310 310 285 285 285 285 285 285 285 285 285 285 285 285 296 296 296 296 296 296 296 296 287 287 287 287 302 302 304 304 304 304 Please contact your point of sale regarding low-speed sensors. Index by Model No. 9WP1224M101 9WP1224M1011 9WP1248H101 9WP1248H1011 9WP1248M101 9WP1248M1011 9WS0812F401 9WS0812F4011 9WS0812H401 9WS0812H4011 9WS0812M401 9WS0812M4011 9WS0824F401 9WS0824F4011 9WS0824H401 9WS0824H4011 9WS0824M401 9WS0824M4011 9WS0912F401 9WS0912H401 9WS0912L401 9WS0912M401 9WS0924F401 9WS0924H401 9WS0924L401 9WS0924M401 9WV0812P1M001 9WV0812P1M0011 9WV0848P1H001 9WV0848P1H0011 9WV0924P1H001 9WV0948P1H001 9WV1212P1J001 9WV1224P1H001 9WV1224P1J601 9WV1248P1J001 With pulse sensor Frame size (certification status is for the models listed in this catalog, Rib and standards for optional page model numbers may differ.) DC Models listed in the main section of this catalog (models not listed in the main section of this catalog are options. Standards for optional model numbers may differ from the certified standards listed at right. Contact us for details of models with "-" model numbers.) 581 Index by Model No./Safety Standards List - ACDC Fans Models listed in the main section of this catalog 9AD0901H12 9AD0901H121 9AD0901H1H 9AD0901H1H1 9AD0901M12 9AD0901M121 9AD0901M1H 9AD0901M1H1 9AD1201H12 9AD1201H121 9AD1201H1H 9AD1201H1H1 Frame size 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 92 x 92 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm Model San Ace 92AD San Ace 92AD San Ace 92AD San Ace 92AD San Ace 92AD San Ace 92AD San Ace 92AD San Ace 92AD San Ace 120AD San Ace 120AD San Ace 120AD San Ace 120AD Rated voltage [V] 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 100 to 240 AC UL CSA TUV cULcUL CE PSE CE PSE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Note Ribbed Ribless Ribbed Ribless Ribbed Ribless Ribbed Ribless Ribbed Ribless Ribbed Ribless page 476 476 476 476 476 476 476 476 479 479 479 479 Please contact your point of sale for pulse sensors and lock sensors. Index by Model No./Safety Standards List - AC Fans AC Models listed in the main section of this catalog CSA TUV 109-033UL 109-040UL 109-041UL 109-043UL 109-044UL 109-047UL 109-130 109-133 109-150 109-151 109-153 109-154 109-180 109-183 109-210 109-213 109-311 109-312 109-313 109-314 109-371 109-372 109-373 109-374 109-601 109-602 109-603 109-604 109-641 109-642 109-643 109-644 109S005 109S005UL 109S006 109S006UL 109S008 109S008UL 109S010 109S010UL 109S013 109S013UL 109S024 109S024UL 109S025 109S025UL 109S029UL 582 Frame size 80 x 80 x 42 mm 80 x 80 x 42 mm 80 x 80 x 42 mm 80 x 80 x 42 mm 80 x 80 x 42 mm 80 x 80 x 42 mm 60 x 60 x 38 mm 60 x 60 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 80 x 80 x 38 mm 60 x 60 x 28 mm 60 x 60 x 28 mm 80 x 80 x 20 mm 80 x 80 x 20 mm o 172 x 51 mmRound type) o 172 x 51 mmRound type) o 172 x 51 mmRound type) o 172 x 51 mmRound type) o 172 x 51 mmwith sensor) o 172 x 51 mmwith sensor) o 172 x 51 mmwith sensor) o 172 x 51 mmwith sensor) 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mmwith sensor) 160 x 160 x 51 mmwith sensor) 160 x 160 x 51 mmwith sensor) 160 x 160 x 51 mmwith sensor) 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm Model San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 60 San Ace 60 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 60 San Ace 60 San Ace 80 San Ace 80 San Ace 172 San Ace 172 San Ace 172 San Ace 172 San Ace 172 San Ace 172 San Ace 172 San Ace 172 San Ace 160 San Ace 160 San Ace 160 San Ace 160 San Ace 160 San Ace 160 San Ace 160 San Ace 160 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 Rated voltage [V] UL 115 100 200 115 230 100 100 115 100 200 115 230 100 115 100 115 100 200 230 115 100 200 230 115 100 200 230 115 100 200 230 115 100 100 100 100/115 200 200 200 200/240 100 100 120 115 230 230 100 - - - - - - - - - - - - - - Note page 494 494 494 494 494 494 486 486 492 492 492 492 484 484 488 488 514 514 514 514 514 514 514 514 509 509 509 509 509 509 509 509 504 504 504 504 504 504 504 504 504 504 504 504 504 504 504 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 80 x 80 x 25 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 120 x 120 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm 92 x 92 x 25 mm o 172 x 150 x 51 mmSidecut type) o 172 x 150 x 51 mmSidecut type) o 172 x 150 x 51 mmSidecut type) o 172 x 150 x 51 mmSidecut type) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 38 mmwith sensor) 120 x 120 x 25 mmwith sensor) 120 x 120 x 25 mmwith sensor) 120 x 120 x 25 mmwith sensor) 120 x 120 x 25 mmwith sensor) 120 x 120 x 25 mmwith sensor) 92 x 92 x 25 mmwith sensor) 92 x 92 x 25 mmwith sensor) 92 x 92 x 25 mmwith sensor) 92 x 92 x 25 mmwith sensor) 92 x 92 x 25 mmwith sensor) 92 x 92 x 25 mmwith sensor) Model San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 80 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 172 San Ace 172 San Ace 172 San Ace 172 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 120 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 San Ace 92 Rated voltage [V] UL 100 200 115 230 100 200 115 230 230 115 100 200 100 200 115 115 100 100 230 200 230 100 200 115 230 100 100 200 115 230 100 200 230 115 100 100 200 115 230 100 230 115 100 200 115 100 100 230 200 100 200 115 230 100 100 CSA TUV - - - - - - - - - - - - - - - - - - - - - CE PSE Note page 490 490 490 490 490 490 490 490 504 504 504 504 500 500 500 500 500 500 500 500 500 496 496 496 496 496 496 496 496 496 512 512 512 512 505 505 505 505 505 505 505 505 505 505 500 500 500 500 500 496 496 496 496 496 496 583 Index by Model No. 109S030 109S031 109S033 109S034 109S050 109S051 109S053 109S054 109S072UL 109S074UL 109S075UL 109S078UL 109S081 109S082 109S083 109S084 109S085 109S086 109S087 109S088 109S089 109S091 109S092 109S093 109S094 109S095 109S096 109S192 109S193 109S194 109S301 109S302 109S303 109S304 109S405UL 109S406UL 109S408UL 109S424UL 109S425UL 109S429UL 109S472UL 109S474UL 109S475UL 109S478UL 109S484 109S485 109S486 109S487 109S488 109S491 109S492 109S493 109S494 109S495 109S496 Frame size AC Models listed in the main section of this catalog Index by Model No. - Options Finger Guards Model no. 109-019C 109-019E 109-019H 109-019K 109-049C 109-049E 109-049H 109-059 109-059H 109-099C 109-099E 109-099H 109-1050 109-1051 109-1052 109-1065 109-1066 109-1068 109-1102 109-1103 109-1104 109-1104H 109-1112 109-1128 109-1137 109-1137H 109-1138 109-1138H 109-1139 109-1146 109-1147 109-139E 109-139H 109-149 109-149E 109-319E 109-319H 109-319J 109-320 109-619E 109-619H 109-620 109-719 109-719H 109-720 109-720H 109-721 109-721H 109-722 109-722H 109-723 584 DC Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Finger Guards Resin Finger Guards/Resin Filter Kits AC Category Matching fan size page Model no. 120 mm sq. type 120 mm sq. type 120 mm sq. type 120 mm sq. type 80 mm sq. type 80 mm sq. type 80 mm sq. type 40 mm sq. type 40 mm sq. type 92 mm sq. type 92 mm sq., o100 mm type 92 mm sq., o100 mm type 36 mm sq. type 150 mm sq. type 150 mm sq. type 38 mm sq. type o172 mm type o 172 mm type o 200 mm type o 200 mm type o 150 mm type o 150 mm type o 133 mm type 70 mm sq. type o 225 mm type o 225 mm type o 221 mm type o 221 mm type o 136 mm type 270 mm sq. type o 92 mm type 60 mm sq. type 60 mm sq. type 52 mm sq. type 52 mm sq. type o 172 mm type o 172 mm type o 172 mm type o 172 mm type 160 mm sq. type 160 mm sq. type 160 mm sq. type 140 mm sq. type 140 mm sq. type o 200 mm type o 200 mm type o 200 mm type o 200 mm type 127 mm sq., o175 mm type 127 mm sq., o175 mm type 127 mm sq. type 533 533 533 533 532 532 532 532 532 532 532 532 532 533 533 532 534 534 535 535 533 533 533 532 535 535 535 535 533 536 532 532 532 532 532 534 534 534 534 533 533 533 533 533 535 535 535 535 533 533 533 109-1000F13 109-1000F20 109-1000F30 109-1000F40 109-1001F13 109-1001F20 109-1001F30 109-1001F40 109-1002F13 109-1002F20 109-1002F30 109-1002F40 109-1003F13 109-1003F20 109-1003F30 109-1003F40 109-1000G 109-1001G 109-1002G 109-1003G Category Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Filter Kits Resin Finger Guards Resin Finger Guards Resin Finger Guards Resin Finger Guards Replacement filter Model no. 109-1000M13 109-1000M20 109-1000M30 109-1000M40 109-1001M13 109-1001M20 109-1001M30 109-1001M40 109-1002M13 109-1002M20 109-1002M30 109-1002M40 109-1003M13 109-1003M20 109-1003M30 109-1003M40 DC Category Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter Replacement filter DC AC Matching fan size page 120 mm sq. type 120 mm sq. type 120 mm sq. type 120 mm sq. type 92 mm sq. type 92 mm sq. type 92 mm sq. type 92 mm sq. type 80 mm sq. type 80 mm sq. type 80 mm sq. type 80 mm sq. type 60 mm sq. type 60 mm sq. type 60 mm sq. type 60 mm sq. type 120 mm sq. type 92 mm sq. type 80 mm sq. type 60 mm sq. type 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 539 539 539 539 Matching fan size page 120 mm sq. type 120 mm sq. type 120 mm sq. type 120 mm sq. type 92 mm sq. type 92 mm sq. type 92 mm sq. type 92 mm sq. type 80 mm sq. type 80 mm sq. type 80 mm sq. type 80 mm sq. type 60 mm sq. type 60 mm sq. type 60 mm sq. type 60 mm sq. type 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 AC and splash proof centrifugal fan Model no. 109-1036 109-1037 109-1038 109-1039 109-1040 109-1069 109-1069H 109-1073 109-1073H 109-1080 109-1081 109-1081H 109-1134 109-1134H 109-1135 109-1135H Category Model no. Matching fan size EMC guards EMC guards EMC guards EMC guards EMC guards Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Inlet nozzle for centrifugal fan and splash proof centrifugal fan Filter kits/Screen kits Category 109-018 Filter kits 109-020 Screen kits DC o 172 mm type 120 mm sq. type 80 mm sq. type 80 mm sq. type 92 mm sq. type o 133 mm type o 133 mm type o 175 mm type o 175 mm type o 100 mm type o 150 mm type o 150 mm type o 225 mm type o 225 mm type o 221 mm type o 221 mm type Model no. page 538 538 538 538 538 537 537 537 537 537 537 537 537 537 537 537 AC Matching fan size Note 120 x 120 x 38 mm Not mountable on AC fans with a sensor or 120 x 120 x 38 mm ACDC fans. Plug Cord 489-006-L10 489-006-L21 489-006-L35 489-007-L10 489-007-L21 489-008-L10 489-008-L21 489-008-L35 UL AC CSA PSE 489-016-L10 489-016-L21 489-037-L10 489-037-L21 489-037-L35 489-047-L10 489-047-L21 489-084-L10 489-084-L21 489-086-L10 489-086-L21 489-1618-L10 489-1618-L21 489-1618-L28 page 541 541 489-1619-L10 489-1619-L21 489-1635-L10 489-1635-L21 Applicable model 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 80 x 80 x 42 mm 80 x 80 x 42 mm 80 x 80 x 42 mm 120 x 120 x 25 mm 92 x 92 x 25 mm 80 x 80 x 25 mm 80 x 80 x 38 mm 120 x 120 x 25 mm 92 x 92 x 25 mm 80 x 80 x 25 mm 80 x 80 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 38 mm 120 x 120 x 25 mm 92 x 92 x 25 mm 80 x 80 x 25 mm 80 x 80 x 38 mm 120 x 120 x 25 mm 92 x 92 x 25 mm 80 x 80 x 25 mm 80 x 80 x 38 mm o 172 x 51 mm o 172 x 150 x 51 mm 160 x 160 x 51 mm o 172 x 51 mm o 172 x 150 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm 160 x 160 x 51 mm o 172 x 51 mm o 172 x 150 x 51 mm 160 x 160 x 51 mm o 172 x 51 mm o 172 x 150 x 51 mm 160 x 160 x 51 mm ACDC Fan page 542 542 542 543 543 542 542 542 542 542 542 542 542 543 543 543 543 543 543 542 542 542 542 542 543 543 Reco mmended connectors for DC fans page 544 Index by Model No. EMC guards/Inlet nozzle for centrifugal fan 585 Deleted Models in this Catalog Following models were deleted in this latest version of catalog. However, these models are not discontinued product. Please contact us for further assistance if necessary. DC Fan Size Model no. Frame material Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure [V] [V] [A] [W] [min-1] [m/min] [CFM] [Pa] 1.9 1.0 1.9 1.45 1.0 0.63 45.6 24 45.6 34.8 24 15.12 3200 2600 3200 2800 2600 2100 10.45 8.2 10.45 9 8.2 6.7 369 289.5 369 317.8 289.5 236.6 287.1 192 287.1 215.6 192 115.4 o 200 x 70 mm o 200 x 70 mm 109E2024S001 109E2024H001 Aluminum Aluminum 24 24 21.6 to 26.4 20.4 to 27.6 o 200 x 70 mm 109E2024AS001 Aluminum 24 21.6 to 26.4 o 200 x 70 mm 109E2024MH001 Aluminum 24 20.4 to 27.6 SPL Operating temperature [inchHO] [dB (A)] 1.153 0.771 1.153 0.865 0.771 0.463 57 51 57 54 51 45 Expected life [C] [h] -10 to +70 -10 to +70 40000 40000 -10 to +70 40000 -10 to +70 40000 Counter Rotating Fan Size Model no. Frame material Rated voltage Operating voltage range Rated current Rated input [V] [V] [A] [W] Rated speed Max. airflow [min-1] [m/min] [CFM] Inlet 40 x 40 x 56 mm 40 x 40 x 56 mm 40 x 40 x 56 mm 60 x 60 x 76 mm 60 x 60 x 76 mm 80 x 80 x 80 mm 80 x 80 x 80 mm 9CRA0412K501 9CRA0412J501 9CRA0412G501 9CR0612S001 9CR0612H001 9CR0812S801 9CR0812H801 Size 60 x 60 x 76 mm 80 x 80 x 80 mm Model no. Plastic Plastic Plastic Plastic Plastic Plastic Plastic Frame material 12 12 12 12 12 12 12 10.8 to 12.6 10.8 to 13.2 10.8 to 13.2 10.8 to 13.2 10.8 to 13.2 10.8 to 13.2 10.8 to 13.2 1.8 1.4 1.0 3.2 2.7 5.5 3.6 21.6 16.8 12 38.4 32.4 66.0 43.2 [V] [kHz] [A] [Pa] SPL Operating temperature Expected life [inchHO] [dB (A)] [C] [h] -20 to +60 -20 to +70 -20 to +70 -10 to +60 -10 to +60 -10 to +60 -10 to +60 40000 40000 40000 40000 40000 40000 40000 Outlet 17000 13000 15800 12200 14000 10400 11500 7000 10300 6500 8000 5300 7000 4600 0.95 0.9 0.77 2.26 1.98 4.53 3.97 33.5 31.8 27.2 80 70 160 140 Rated speed [min -1] Rated voltage PWM frequency Rated current Max. static pressure 650 570 435 550 450 520 400 2.61 2.29 1.75 2.21 1.81 2.09 1.61 Max. airflow Duty cycle 0% Duty cycle 100% 65 62 59 66 64 71 68 SPL Expected Life [m3/min] [CFM] Max. static pressure [Pa] [inchH2O] [dB (A)] [h] 9CR0612P0S03 Plastic 12 25.0 3.2 Inlet: 1300 Outlet: 800 Inlet: 11500 Outlet: 7000 2.26 79.8 550 2.21 66 40000 9CR0612P0H03 Plastic 12 25.0 2.7 Inlet: 1200 Outlet: 800 Inlet: 10300 Outlet: 6500 1.98 69.91 450 1.81 64 40000 9CR0848P8S03 Plastic 48 25.0 1.29 Inlet: 2000 Outlet: 1300 Inlet: 8000 Outlet: 5300 4.53 159.95 520 2.09 71 40000 Size Model no. Frame Rated voltage Operating voltage range PWM duty cycle* Rated current Rated input material [V] [V] [%] [A] [W] Rated speed Max. airflow [min-1] [m/min] [CFM] Inlet 40 x 40 x 56 mm 9CRB0412P5S201 Plastic 12 10.8 to 13.2 40 x 40 x 56 mm 9CRB0412P5K001 Plastic 12 10.8 to 13.2 40 x 40 x 56 mm 9CRB0412P5J201 Plastic 12 10.8 to 13.2 100 0 100 0 100 0 1.4 0.09 0.88 0.11 0.72 0.07 Max. static pressure [Pa] SPL Operating temperature Expected life [inchHO] [dB (A)] [C] [h] -20 to +70 -20 to +70 -20 to +70 -20 to +70 -20 to +70 -20 to +70 40000 40000 40000 40000 40000 40000 Outlet 16.8 22000 19700 0.9 31.8 1045 1.08 3800 3500 0.15 5.3 31 10.56 19000 17000 0.76 26.83 730 1.32 5700 5100 0.21 7.41 67 8.64 17300 16000 0.71 25.1 650 0.84 3450 3200 0.13 4.59 26 4.197 0.124 2.93 0.26 2.61 0.1 68 26 62 33 61 24 * PWM frequency: 25 kHz Long Life Fan Size 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 60 x 60 x 25 mm 586 Model no. 109L0612G401 109L0612S401 109L0612H401 109L0612F401 109L0612M401 109L0624D401 109L0624S401 109L0624H401 109L0624F401 109L0624M401 109L0648G401 109L0648H401 Frame material Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Rated voltage Operating voltage range Rated current Rated input Rated speed [V] [V] [A] [W] 12 12 12 12 12 24 24 24 24 24 48 48 10.2 to 13.8 10.2 to 13.8 10.2 to 13.8 10.2 to 13.8 10.2 to 13.8 20.4 to 27.6 20.4 to 27.6 20.4 to 27.6 20.4 to 27.6 20.4 to 27.6 40.8 to 55.2 40 to 53 0.24 0.17 0.11 0.09 0.06 0.12 0.08 0.06 0.05 0.04 0.07 0.04 2.88 2.04 1.32 1.08 0.72 2.88 1.92 1.44 1.2 0.96 3.36 1.92 [min-1] 5600 4600 3800 3200 2600 5150 4600 3800 3200 2600 5600 3800 Max. airflow [m/min] 0.78 0.65 0.53 0.44 0.36 0.72 0.65 0.53 0.44 0.36 0.78 0.53 Max. static pressure [CFM] [Pa] 27.5 23.0 18.7 15.5 12.7 25.4 23.0 18.7 15.5 12.7 27.5 18.7 87.3 56.8 40.2 29.4 19.6 73.8 56.8 40.2 29.4 19.6 87.3 40.2 SPL [inchHO] [dB (A)] 0.35 0.228 0.161 0.118 0.079 0.296 0.23 0.161 0.118 0.079 0.35 0.161 39 33 28 24 20 37 33 28 24 20 39 28 Operating temperature [C] -20 to -20 to -20 to -20 to -20 to -20 to -20 to -20 to -20 to -20 to -20 to -20 to Expected life [h] +70 +70 +70 +70 +70 +70 +70 +70 +70 +70 +60 +70 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 80000 100000 Deleted Models in this Catalog Thermally Controlled Fan Size Model no. Frame material Rated voltage Operating voltage range Rated current Rated input Rated speed [V] [V] 52 x 52 x 15 mm 109P0512T7H12 Plastic 12 10.2 to 13.8 52 x 52 x 15 mm 109P0512T7H122 Plastic 12 10.2 to 13.8 60 x 60 x 15 mm 109P0612T7H12 Plastic 12 10.2 to 13.8 60 x 60 x 15 mm 109P0612T7H122 Plastic 12 10.2 to 13.8 60 x 60 x 20 mm 109P0612T6H12 Plastic 12 10.2 to 13.8 60 x 60 x 20 mm 109P0612T6H122 Plastic 12 10.2 to 13.8 60 x 60 x 25 mm 109R0612T4H12 109R0612T4H121 Plastic 12 10.2 to 13.8 60 x 60 x 25 mm 109R0612T4H122 109R0612T4H123 Plastic 12 10.2 to 13.8 80 x 80 x 20 mm 109P0812T6H12 Plastic 12 10.2 to 13.8 80 x 80 x 20 mm 109P0812T6H122 Plastic 12 10.2 to 13.8 80 x 80 x 25 mm 109R0812T4H12 109R0812T4H121 Plastic 12 10.2 to 13.8 80 x 80 x 25 mm 109R0812T4H122 109R0812T4H123 Plastic 12 10.2 to 13.8 Max. airflow Max. static pressure [A] [W] [min-1] [m/min] [CFM] [Pa] 0.13 0.09 0.13 0.09 0.12 0.08 0.12 0.08 0.15 0.1 0.15 0.1 0.13 0.1 0.13 0.1 0.18 0.1 0.18 0.1 0.14 0.09 0.14 0.09 1.56 1.08 1.56 1.08 1.44 0.96 1.44 0.96 1.8 1.2 1.8 1.2 1.56 1.2 1.56 1.2 2.16 1.2 2.16 1.2 1.68 1.08 1.68 1.08 4600 2300 4900 2400 4100 2050 4300 2100 4200 2100 4400 2150 3800 1900 3950 1950 2900 1450 3050 1450 2900 1450 3000 1450 0.255 0.13 0.27 0.14 0.4 0.2 0.42 0.2 0.42 0.21 0.44 0.22 0.53 0.26 0.55 0.27 0.84 0.42 0.88 0.42 1.03 0.51 1.07 0.51 9.0 4.6 9.5 4.9 14.1 7.1 14.8 7.0 14.8 7.4 15.5 7.8 18.7 9.2 19.4 9.5 29.7 14.8 31.0 14.8 36.4 18.0 37.8 18.0 31.9 8.8 36.2 9.6 38.2 9.3 42.0 9.7 31.9 8.8 35.0 9.2 40.2 9.8 41.8 10.3 29.4 7.4 32.5 7.4 35.3 8.8 37.7 8.8 SPL [inchHO] [dB (A)] 0.128 0.035 0.145 0.039 0.153 0.037 0.169 0.039 0.128 0.035 0.141 0.037 0.161 0.039 0.168 0.041 0.118 0.03 0.131 0.03 0.142 0.035 0.151 0.035 27 17 28 17 32 18 32 18 31 21 33 21 28 15 28 15 31 18 32 20 29 14 29 14 Operating temperature Expected life [C] [h] -10 to +70 60000 -10 to +70 60000 -10 to +70 60000 -10 to +70 60000 -10 to +70 60000 -10 to +70 60000 -10 to +60 60000 -10 to +60 60000 -10 to +60 60000 -10 to +60 60000 -10 to +60 60000 -10 to +60 60000 Operating temperature Expected life Blower Size 120 x 32 mm 120 x 32 mm 120 x 32 mm 120 x 32 mm Model no. Frame material 109BF12HC2 109BF12MC2 109BF24HC2 109BF24MC2 Plastic Plastic Plastic Plastic Rated voltage Operating voltage range Rated current Rated input Rated speed [V] [V] [A] [W] [min-1] 12 12 24 24 10.2 to 13.8 10.2 to 13.8 20.4 to 27.6 20.4 to 27.6 0.6 0.32 0.3 0.16 7.2 3.84 7.2 3.84 2400 1900 2400 1900 Max. airflow [m/min] 0.78 0.61 0.78 0.61 Max. static pressure [CFM] [Pa] 27.5 21.5 27.5 21.5 175.4 109.8 175.4 109.8 SPL [inchHO] [dB (A)] 0.704 0.441 0.704 0.441 52 44 52 44 [C] [h] -20 to +60 -20 to +60 -20 to +60 -20 to +60 40000 40000 40000 40000 DC Deleted Models in this Catalog Storage temperature is -30 to +70C. 587 Distributors Product availability may vary by distributor or branch. ARGENTINA Digi-Key Electronics TEL: +1 218 681 7979 FAX: +1 218 681 3380 AUSTRALIA BRAEMAC PTY LTD 1/59-61 Burrows Road, Alexandria NSW 2015, Australia TEL: +61 2 9550 6600 FAX: +61 2 9550 6377 AUSTRALIA Avnet Electronics Marketing Asia Sydney (NSW) 9B, 9-11 South Street, Rydalmere NSW 2116, Australia TEL: +61 2 9585 5511 FAX: +61 2 9585 5519 AUSTRALIA Arwon Solutions PTY LTD 17a Dennis Street Cambellfield Vic 3061, Australia TEL: +61 3 9308 9085 FAX: +61 3 9308 8644 AUSTRALIA Aldus-Tronics PTY LTD 41-43 Lakeside Drive, Broadmeadows Vic 3047, Australia TEL: 61 (0)3 9355 2300 FAX: +61 3 9464 2538 BELGIUM SERVOTRONIC BVBA Harmonielaan 2, 2960 Brecht, Belgium TEL: +32 3 326 4666 FAX: +32 3 326 1393 BRAZIL Digi-Key Electronics TEL: +1 218 681 7979 FAX: +1 218 681 3380 BRAZIL Newark Electronics Corporation TEL: +1 800 463 9275 FAX: +1 888 551 4801 CANADA Arrow Electronics, Inc. Please see locations at; https://www.arrow.com/en/support/contact-support/find-an-arrow-office?country=CA_Offices TEL: +1 855 326 4757 CANADA Digi-Key Electronics TEL: +1 800 344 4539 FAX: +1 218 681 3380 CANADA Marsh Electronics, Inc. TEL: +1 800 926 2774 FAX: +1 414 771 2847 CANADA Mouser Electronics, Inc. 137 Glasgow Street, Unit 475 A, Kitchener, Ontario N2G 4X8, Canada TEL: +1 800 346 6873 FAX: +1 519 570 2668 CANADA Newark Electronics Corporation TEL: +1 800 463 9275 FAX: +1 888 551 4801 : Cooling Fan : Uninterruptible Power Supply : Servo System CHINA SHANGHAI GO-WELL ELECTRICAL TECHNOLOGY CO.,LTD. 6th Floor, No.173, Jiangchang 3rd Road, Zhabei District, Shanghai, 200436, China TEL: +86 21 6630 0101 FAX:+86 21 5080 2962 CHINA Shanghai Comtech Electronic Technology Co.Ltd. Rm.604, Golden Magnolia Plaza,No.1 Dapu Road Shanghai China 200023 TEL: +86 21 63900088 FAX: +86 21 53850872/73 CHINA BEIJING GO-WELL YANGHAI ELECTRICAL TECHNOLOGY CO., LTD. Room 1106, Weixing Building, No.63, Zhichun Road, Haidian District, Beijing 100190, China TEL: +86 10 8286 7980 FAX: +86 10 8286 7987 CHINA MELCO INDUSTRIAL SUPPLIES TRADING (SHANGHAI) CO., LTD Flat B, 9/F, DaTong Commercial Tower, No.369 FuXing Road Central, Shanghai 200025, China TEL: +86 21 6320 1250 FAX: +86 21 6320 0079 CHINA 36 1801-1803 TEL: +86 20 8326 6170 FAX: +86 20 8326 6180 CHINA SHEN SING COMPANY LIMITED (Wu Xi Office) 18th floor, Unit H, Wah Kwong Building, 333 Zhong Shan Road, Wu Xi, Jian Su, China, 214001 TEL: +86 510 8273 8091 FAX: +86 510 8276 3243 CHINA SHANGHAI LVMAC INTERNATIONAL TRADE CO.,LTD Room 203, Unit 1, No. 333 HongQiao Road, Xuhui District, Shanghai-200030, CHINA TEL: +86 21 6432 6969 FAX: +86 86 21 6432 5092 CHINA QuadRep Electronics CO., Ltd (Shanghai) Room 707, Block A, Lane 547, West Tian Mu Rd, Shanghai, China, 200070 TEL: +86 21 6317 5445 FAX: +86 21 6317 6042 CHINA SHANGHAI AL-CHARM INTERNATIONAL TRADING CO.,LTD. Unit 1303 Haisen International Mansion, No.1 Lane 829, Wanhang Du Road Shanghai, 200042, China TEL: +86 21 6232 5024/21 6232 5025/21 6232 5026/21 6232 5027 FAX: +86 21 6232 5023 CHINA Kunshan Zhanxu Electronics Co., Ltd. 8 Floor Building 1 Jiayu International Plaza Chunhui Road, Kunshan City, Jiangsu Province, China TEL: +86 512 5035 7819 FAX: +86 512 5035 7819 CHINA TianJin Ringbert Trading International Co.,Ltd Room 618, Hua Ying Mansion, Central Avenue, Airport Free Trade Zone, Tianjin, China TEL: +86 22 8490 6916 FAX: +86 22 8725 0855 CANADA PUI (Projections Unlimited, Inc.) TEL: +1 800 551 4405 FAX: +1 949 789 0626 CHINA G TEL: +86 20 8737 0307 FAX: +86 20 8737 0501 CANADA Sager Electronics, Inc. 200 Matheson Blvd. West, Suite 105, Mississauga, Ontario L5R 3L7 Canada TEL: +1 800 724 3780 FAX: +1 905 755 8889 CHINA GUANGZHOU GO-WELL ELECTRICAL TECHNOLOGY CO.,LTD. 2001, Huaxin Center, 450 Huanshi East Rd, Guanzhou, Guangdong, 510075, China TEL: +86 20 2226 3940 FAX: +86 20 2226 3947 CANADA Tonar Industries TEL: +1 800 568 6627 FAX: +1 973 586 2075 CHINA 504 TEL: +86 10 84364529 /139 1058 7268 FAX: +86 10 84364529 CANADA Epic Technical Sales, Inc. 1925 18th Avenue NE, Suite 115, Calgary, AB T2E 7T8, Canada TEL: +1 403 769 1881 FAX: +1 403 769 1981 CANADA Pipe-Thompson Technologies Inc. 1100 Burloak Drive, Suite 300 Burlington, Ontario, Canada L7L 6B2, Canada TEL: +1 905 332 2758 CANADA COWPER, INC 677-7E Avenue Lachine, Montreal, QUE, Canada TEL: +1 514 637 6746 FAX: +1 514 637 5055 CHINA Shanghai TangYuan Electronics & Components Co., Ltd Room 417, Building A, No.7001 ZhongChun Road, MingGu Technical Park, Shanghai, China TEL: +86 21 54796300/+86 21 54462301 FAX: +86 21 54728933 588 CHINA 288 B 303 TEL: +86 755 2685 9975 FAX: +86 755 2685 9977 CHINA Capital Technology Co., Ltd. Room 1601-1603, TianLiao Commercial Building, TaoYuan Street, XiLi, NanShan District, Shenzhen, China TEL: +86 755 2783 7331 / 2302 9006 FAX: +86 755 230 76120 CHINA ARROW ELECTRONICS(SHENZHEN) CO., LTD. No 2,3/F, Changpin, Honghua Road, 99 Futian Free Trade Zone, Shenzhen, China TEL: +86 755 8250 5310 FAX: +86 755 8250 5311 CHINA A TEL: +86 755 2689 1790 FAX: +86 755 2689 1794 GERMANY Avnet EMG GmbH Gaussstrasse 10 31275 Lehrte, Germany TEL: +49 5132 5099 0 FAX: +49 5132 5099 76 CHINA 1 501 TEL: +86 755 2682 2456 FAX: +86 755 2682 2456 GERMANY Telemeter Electronic GmbH Joseph-Gaensler-strasse 10, 86609 Donauwoerth, Germany TEL: +49 906 706 93 0 FAX: +49 906 706 93 50 CHINA 1101 TEL: +86 769 89300113 FAX: +86 769 81181876 GERMANY R.T.A. Deutschland GmbH Bublitzer Strasse 34 40599 Duesseldorf, Germany TEL: +49 211 74966860 FAX: +49 211 74966866 CHINA Nanjing SADE Auto Equipment Co.,Ltd Rm,105,NO.29 Yudao Street,Baixia District TEL: +86 25 84890636/84891028/84490028 FAX: +86 25 84890635 GERMANY MJC Elektrotechnik GmbH Am Gielbrunnen 17 67304 Eisenberg, Germany TEL: +49 63 51 12767 0 FAX: +49 63 51 12767 50 CHINA 713 TEL: +86 755 2332 7569 FAX: +86 755 2791 8003 CHINA A 12F TEL: +86 755 8318 0960 FAX: +86 755 8318 0961 CHINA 703-711 TEL: +86 755 6111 1040 FAX: +86 755 6111 1036 CHINA 1 1 TEL: +86 755 2811 8565 FAX: +86 755 2811 6101 CHINA 7018 A 6 TEL: +86 755 8280 5000 FAX: +86 755 82805100 CHINA 486 1108 TEL: +86 28 8778 3845 FAX: +86 28 8778 3847 CZECH REPUBLIC ENIKA spol. s.r.o. Vlkov 33, Nova Paka Pod Harfou 933/86 190 00 Praha 9, Czech Republic TEL: +420 493 77 33 11 FAX: +420 493 77 33 22 DENMARK WEXOE A/S Lejrvej 31 3500 Vaerlose, Denmark TEL: +45 4485 0485 FAX: +45 4494 9989 EGYPT PONT EGYPT 4, Aiashwal Street, End of Al Haram Street Giza, Egypt TEL: +20 2 374 18247 FAX: +202 374 18108 EGYPT EGYELECTRONICS 58 ABD EL HAMEID GOUDA AL SAHAR ST SECTION SIX ZAHRAA EL MAADI TEL: +202 275 15108 FAX: +202 275 15108 FINLAND WEXON OY TURVEKUJA 6 FI-00700 HELSINKI TEL: +358 9 290 440 FAX: +358 9 290 44100 FRANCE A.E. SERVICE Parc Activite du Cret de Mars, 42150 La Ricamarie, France TEL: +33 04 77 41 21 47 FAX: +33 04 77 25 80 29 FRANCE AUBE Electronique ZAC de l'ecluse des Marots 10800 Saint Thibault, France TEL: +33 03 25 40 44 41 FAX: +33 03 25 40 44 42 GERMANY Tronic One GmbH Muhlweg 2b, 82054 Sauerlach, Germany TEL: +49 8104 90951 0 FAX: +49 8104 90951 69 HONGKONG Melco Industrial Supplies Co., Ltd. 10th Floor, Bilion Plaza 2, No.10 Cheung Yue Street, Cheung Sha Wan, Kowloon, Hong Kong TEL: +852 2386 7881 FAX: +852 2387 4057 HUNGARY Q-TECH Engineering Ltd. & Co. Batthyany Lajos U. 8., 1161 Budapest, Hungary TEL: +36 14 053 338 FAX: +36 14 059 134 INDIA System Controls Technology Solutions Pvt.Ltd. #73/B, Keonics Industrial Estate, Electronic City, Bangalore - 560 100 India TEL: +91 80 40820400,144,405,406 FAX: +91 80 40820426 INDIA Flexible Automation System PVT. LTD #412, Prestige Centre Point Cunningham Road, Bangalore -560 052, India TEL: +91 80 2228 2427 FAX: +91 80 2225 7108 INDIA Strategi Automation Solutions Pvt. Ltd. Plot No.25/B, Doddanakundi Iddl Estate, Off Whitefield Road Behind Graphite India, Bangalore-560048, India TEL: +91 80 32489798 FAX: +91 80 41163047 INDIA Arrow Electronics India Pvt. Ltd. Fortune Summit, Ward No.174, 6th Sector, HSR Layout, Roopena Agrahara, Bangalore - 560 068, India TEL: +91 80 41353800 FAX: +91 80 41127784 INDIA Global Technocrats Inc. 302, Gupta Tower II, G-33, Vikas Puri, New Delhi-110018, India TEL: +91 12 42386745 FAX: +91 11 28542884 INDIA ITP Electronics Pvt. Ltd. 27, Electronic City, Sector-18, Gurgaon-122016 (Haryana), India TEL: +91 12 44 013646 INDONESIA PT. TOKAI ELECTRONICS INDONESIA BEFA SQUARE UNIT 3-J LANTAI 3 JALAN KALIMANTAN KAWASAN INDUSTRI MM2100 GANDASARI CIKARANG BARAT KAB. BEKASI JAWA BARAT 17530 INDONESIA TEL: +62 21 8980719 INDONESIA PT. DIFA DAYA SELARAS Jln. Palmerah Utara II No.5 Jakarta 11480, Indonesia TEL: +62 21 536 64151 FAX: +62 21 536 52576 INDONESIA PT. Prasindo Agung Mandiri Jl. Alfallah No.18C, Cililitan Besar Raya-Jakarta 13650, Indonesia TEL: +62 8088 8802 Distributors CHINA 65 506 TEL: +86 755 2510 8789/2510 9856 FAX: +86 755 2510 1686 ISRAEL CONLOG Ltd Intergreen Building, POB 3265, 17 Hamefalsim Street., 49130 Petah Tikva, Israel TEL: +972 3 9269555 FAX: +972 3 9233367 ISRAEL ELECTRONDART 9 Ben Zion Gellis Street, 4927909 Petah Tikva, Israel TEL: +972 39314447 FAX: +972 39302867 589 Distributors Product availability may vary by distributor or branch. ISRAEL Radion Engineering Co. Ltd. 11 Ha'sivim St. P.O.B 7111 Petah-Tikvah 4959372 ISRAEL TEL: +972 3 9226688 FAX: +972 3 9226655 ITALY R.T.A. s.r.l. Frazione Divisa Via Enrico Mattei 27020 MARCIGNAGO (PV) Italy TEL: +39 0382 929 855 FAX: +39 0382 929 150 KOREA HY TECH CO., LTD. (former HAN YANG CORP.) #1110 Renaissance Tower, 14, Manlijae-ro, Mapo-gu, Seoul, 04195, Korea TEL: +82 2 713 4343 FAX: +82 2 713 4332 KOREA SAMHWA YANGHENG CO., LTD. #1204, ACE High-end Tower 3rd, 145, Gasan digital 1-ro, Geumcheon-gu, Seoul, 08506, Korea TEL: +82 2 716 4763 FAX: +82 2 718 1873 KOREA TPC MECHATRONICS CORP. 39, Gabmun 2-ro, Seo-gu, Incheon, 22849, Korea TEL: +82 32 580 0016 FAX: +82 32 578 0768 KOREA TELCOM ICP CO., LTD. 5F, Telcom B/D, 76, Seocho-daero, Seocho-gu, Seoul, 06673, Korea TEL: +82 2 3474 9449 FAX: +82 2 3473 9449 KOREA INTERDEVICE Co., Ltd. Rm.1108, Ace Gwangmyeong Tower, 108, Haan-ro, Gwangmyeong-si, Gyeonggi-do, 14319, Korea TEL: +82 2 897 7781 FAX: +82 2 6280 1117 KOREA M.E.T CO., LTD. 46, Techno 11-ro, Yuseong-gu, Daejeon, 34036, Korea TEL: +82 42 934 8257 FAX: +82 42 934 8260 LITHUANIA INOBALT UAB VILHELMO BERBOMO STREET 10-310 92221 KLAIPEDA LITHUANIA TEL: +370 6122 2499 MALAYSIA Flexible Automation System Sdn Bhd (Kuala Lumpur) 60, Jalan USJ10/1B, 47620 UEP Subang Jaya, Selangor, Malaysia TEL: +60 03 5633 1280 FAX: +60 03 5633 6613 MALAYSIA iMS Motion Solution (Penang) Sdn Bhd. 312-E, Jalan Perak, 11600 Pulau Pinang, Malaysia. TEL: +60 4 281 0678 FAX: +60 4 281 1218 MALAYSIA iMS Motion Solution (Johor) Sdn Bhd. No.7, Jalan Sasa 4,Taman Gaya, 81800 Ulu Tiram, Johor Bahru, Johor, Malaysia. TEL: +60 7 863 5240 FAX: +60 7 863 7240 MALAYSIA QuadRep Malaysia Sdn Bhd 570C 3rd Flr, Jalan Sultan Azlan Shah, Sungai Nibong, Penang 11900, Malaysia TEL: +604 6581771 FAX: +604 6582771 MEXICO Arrow Electronics, Inc. Please see locations at; https://www.arrow.com/en/support/contact-support/find-an-arrow-office?country=MX_Offices TEL: +1 855 326 4757 MEXICO Digi-Key Electronics TEL: +1 888 598 1476 FAX: +1 218 681 3380 MEXICO Marsh Electronics, Inc. TEL: +1 800 926 2774 FAX: +1 414 771 2847 MEXICO Mouser Electronics, Inc. Av. Moctezuma #3515 Local 5-C Col. Ciudad del Sol, Zapopan, Jalisco, CP 45050, Mexico TEL: +52 33 3612 7301 FAX: +52 33 3612 7356 MEXICO Newark Electronics Corporation Av. Aviacion No. 5051 Nave 18, Parque Industrial city Park, Zapopan, Jalisco, CP 45019, Mexico TEL: +1 800 463 9275 FAX: +1 800 800 9275 590 : Cooling Fan : Uninterruptible Power Supply : Servo System MEXICO PUI (Projections Unlimited, Inc.) TEL: +1 800 551 4405 FAX: +1 949 789 0626 MEXICO Sager Electronics, Inc. TEL: +1 800 724 3780 FAX: +1 972 312 1823 MEXICO Tonar Industries TEL: +1 800 568 6627 FAX: +1 973 586 2075 MEXICO Carlberg and Associates 451 E. Juanita Ave Suite 1, Mesa, AZ 85204, U.S.A. TEL: +1 602 616 2655 FAX: +1 480 377 0767 MEXICO Fastech Mexico SA de CV Ontario #1791-9 Col. Colomos Providencia Guadalajara, Jalisco, Mexico CP 44660 TEL: +52 33 36 41 50 51/52 MEXICO Westrep 400 N Tustin Avenue Suite #130 Santa Ana, CA 92705, U.S.A. TEL: +1 714 527 2822 FAX: +1 714 527 3868 MOROCCO EL JAOUHARY ELECTRICITE SECTEUR 11 BLOC 13 N 186 HAY SALAM, 11000 SALE TEL: +212 537 808 087 FAX: +212 537 812 665 POLAND SEMICON Sp. Z o.o. UI. Zwolenska 43/43A, 04-761 Varszawa, Poland TEL: +48 22 615 73 71 FAX: +48 22 615 73 75 PORTUGAL PROSISTAV Zona Industrial da Mota, RUA 7 Lte 6 A, Gafanha da Encarnacao, 3830-527 Ilhavo, Portugal TEL: +351 234 397 210 FAX: +351 234 397 219 RUSSIA WEXON OOO 192236, St. Petersburg Sofiyskaya ul., 14 Russia TEL: +7 812 3266503 FAX: +7 812 3266504 SAUDI ARABIA DESERT DIAMOND EST. FOR TRADING PO BOX 29869 RIYADH-11467 KINGDOM OF SAUDI ARABIA TEL: +966 11 2791588 FAX: +966 11 2931254 SINGAPORE NEMATRON CONTROL SYSTEM (ASIA) PTE LTD 209 Henderson Road #01-06 Henderson Ind. Park Singapore 159551 TEL: +65 6278 3289 FAX: +65 6278 8372 SINGAPORE QuadRep Marketing (S) Pte Ltd. 9 Kaki Bukit Road 1, #03-09 Eunos Technolink, Singapore 415938 TEL: +65 6346 1933 FAX: +65 6346 1911 SINGAPORE PBA Systems Pte Ltd 505 Yishun Industrial Park A, PBA Building, Singapore 768733 TEL: +65 6576 6767 FAX: +65 6576 6768 SINGAPORE I-Motion Pte Ltd Blk 15, #05-04 Toa Payoh Lor 8 Braddell Tech, Singapore 319262 TEL: +65 6841 7877 FAX: +65 6280 3655 SINGAPORE Tokai Electronics (S) Pte. Ltd. 10 Anson Road #14-17 International Plaza Singapore 079903 TEL: +65 6224 7796 SINGAPORE Avnet Asia Pte Ltd 151 Lorong Chuan #06-03 New Tech Park Singapore 556741 TEL: +65 6580 4720 FAX: +65 6580 6200 SPAIN DIODE Espana S.A. C/ Sierra de Gudarrama 3 Edificio Europa Escalera B, 2 Planta 28830 San Fernando de Henares Madrid TEL: +34 91 456 81 00 FAX: +34 91 358 06 07 SPAIN RTA IBERICA Callegeneralitat 22, 1 3, 8850 Gava (Barcelona), Spain TEL: +34 936 388 805 FAX: +34 936 334 595 SWEDEN OEM Electronics PO BOX 1025 57329 TRANAS SWEDEN TEL: +46 75 242 45 00 FAX: +46 75 242 45 09 TURKEY ST TEKNO LTD STI Mehmet Akif Mah. Recep Tayyip Erdoan Blv. No:84Dulkadirolu / Kahramanmara TURKEY TEL: +90 344 236 0900 FAX: +90 344 236 0706 SWEDEN OEM Motor AB BOX 1011 57328 TRANAS SWEDEN TEL: +46 75 242 41 00 FAX: +46 76 242 41 19 UNITED KINGDOM EAO LTD. Albert Drive, Burgess Hill, West Sussex RH15 9TN, U.K. TEL: +44 01444 23 6000 FAX: +44 01444 23 6641 SWITZERLAND Telemeter Electronic GmbH Romanshornerstrasse 117, 8280 Kreuzlingen, Switzerland TEL: +41 71 699 20 20 FAX: +41 71 699 20 24 UNITED KINGDOM ERIKS Crakley Way Paertree Industrial Park Dudley, West Midlands DY2 0UW, U.K. TEL: +44 01384246230 FAX: +44 01384246240 SWITZERLAND PowerParts AG Schareggstrasse 1, 5506, Maegenwil, Switzerland TEL: +41 62 896 7080 FAX: +41 62 896 7088 UNITED KINGDOM INTELLIGENT AUTOMATION SYSTEMS Ltd 16 Wood Stock Avenue, UB12QN Southall, Middlesex, U.K. TEL: +44 20 8432 2749 FAX: +44 20 8432 3051 TAIWAN YUNG HO CO., LTD. 5th Floor, 36. Kuan Chien Road, Taipei, Taiwan TEL: +886 2 2311 6561 FAX: +886 2 2311 6469 USA Arrow Electronics, Inc. 9201 E Dry Creek Road, Centennial, CO 80112 Please see other locations at; https://www.arrow.com/en/support/contact-support/find-an-arrow-office?country=US_Offices TEL: +1 855 326 4757 TAIWAN SUNHOLY TRADING CO., LTD. 3F, No.78, Sec 2, Chang An E. Road, Taipei, 104, Taiwan TEL: +886 2 2516 6060 FAX: +886 2 2508 0323 TAIWAN GULF ELECTRICS CO., LTD. No.7, Ln. 133, Gushan 1st Rd., Gushan Dist., Kaohsiung City 804, Taiwan TEL: +886 7 521 9966 FAX: +886 7 521 3535 THAILAND ID MART CO.,LTD 72 Ramintra Road, Minburi, Minburi, Bangkok 10510, Thailand TEL: +66 2 517 0688 FAX: +66 2 517 0863 THAILAND PMC TECHNOLOGY CO., LTD. 99/359 Moo 5 Tambon Bang Krang, Amphur Muang Nonthaburi, Nonthaburi 11000 TEL: +66 2 108 6041 FAX: +66 2 108 6044 THAILAND Flexible Automation System Co.,Ltd 1509 Soi Ladprao 94 (Srivara Town in Town) Wangthonglang, Bangkok 10310, Thailand TEL: +66 2 530 7900 7 FAX: +66 2 530 7908 9 THAILAND QR Electronics (Thailand) Co., Ltd. 167 Boromratchachonnanee Rd. Kweang. Bangbomru, Khet. Bangplad, Bangkok 10700 Thailand. TEL: +66 81 371 1722 FAX: +66 2 886 6515 THAILAND NITTA (Thailand) Co., Ltd. 382/7 Moo 1, Bangsaothong, Bangsaothong, Samutprakarn 10540 Thailand TEL: +66 2 181 7684 FAX: +66 2 181 7685 THE NETHERLANDS M.C. TECHNOLOGY Buys Ballotstraat 31, IND. Area Zandhorst II, 1704 SK Heerhugowaard, the Netherlands TEL: +31 (0)72 5717821 FAX: +31 (0)72 5718461 THE NETHERLANDS TOP-ELECTRONICS BV Postbus 439, 2920 AK Krimpen aan den Ijssel, the Netherlands TEL: +31 180 580 492 TURKEY NETA NAKIS VE MAKINA SANAYI TICARET AKPINAR MAHALLESI SUHEDA CADDESI, No : 2 SANCAKTEPE 34885 ISTANBUL TURKEY TEL: +90 2163390452 TURKEY LINTEK MAKINA ELEKTRONIK TEKNOLOJILERI 1348 SOK. N3/3F Teknik Malzeme, Is Merkezi, Yenisehir, 35110 Izmir, Turkey TEL: +90 232 457 294 FAX: +90 232 457 295 TURKEY ROBOSAN OTOMAYSON SAN.TIC .LTD BAHCELIEVLER MAH. SERPINTI SOK. NO:6 PENDIK 34893 ISTANBUL TURKEY TEL: +90 216 340 39 70 FAX: +90 216 340 39 64 USA Digi-Key Electronics 701 Brooks Avenue South, Thief River Falls, MN 56701 U.S.A. TEL: +1 800 344 4539 FAX: +1 218 681 3380 USA Marsh Electronics, Inc. 1563 South 101st Street, Milwaukee, WI 53214, U.S.A. Please see other locations at; https://www.marshelectronics.com/contact.php TEL: +1 800 926 2774 FAX: +1 414 771 2847 USA Mouser Electronics, Inc. 1000 North Main Street, Mansfield, TX 76063, U.S.A. Please see other locations at; https://www.mouser.com/contact/GlobalBranches.aspx TEL: +1 800 346 6873 FAX: +1 817 804 3899 USA Newark Electronics Corporation 300 S. Riverside Plaza, Suite 2200, Chicago, IL 60606, U.S.A. TEL: +1 800 463 9275 FAX: +1 888 551 4801 USA PUI (Projections Unlimited, Inc.) 15311 Barranca Parkway, Irvine, CA 92618, U.S.A. Please see other locations at; http://www.gopui.com/contacts.htm TEL: +1 800 551 4405 FAX: +1 949 789 0626 USA Sager Electronics, Inc. 19 Leona Drive, Middleborough, MA 02346, U.S.A. Please see other locations at; http://www.sager.com/about-us/locations/ TEL: +1 800 724 3780 FAX: +1 508 947 0869 USA Tonar Industries 419 Franklin Avenue, Rockaway, NJ 07866, U.S.A. Please see other locations at; http://www.tonar.com/contact TEL: +1 800 568 6627 FAX: +1 973 586 2075 USA AID Electronics, Inc. 2425 North Central Expressway, Suite 700, Richardson, TX 75080, U.S.A. TEL: +1 972-478-8700 FAX: +1 972 478 8707 USA Carlberg and Associates 451 E. Juanita Ave Suite 1, Mesa, AZ 85204, U.S.A. TEL: +1 602 616 2655 FAX: +1 480 377 0767 Distributors TAIWAN QuadRep Electronics [Taiwan] Ltd. 17F, No.79, Hsin Tai Wu Road, Sec.1, Hsi-Chih, New Taipei City, Taiwan TEL: +886 2 2698 9933 FAX: +886 2 2698 9911 USA CenTech, Inc. 4025 NE Lakewood Way, Suite 290, Lee's Summit, MO 64064-1703, U.S.A. TEL: +1 816 795 9019 FAX: +1 816 795 0070 USA Epic Technical Sales, Inc. 9400 SW Barnes Road, Suite 305, Portland OR 97225, U.S.A. TEL: +1 503 292 7922 FAX: +1 503 292 7903 591 Distributors Product availability may vary by distributor or branch. : Cooling Fan : Uninterruptible Power Supply : Servo System USA ExisQCI, Inc. 1570 The Alameda Suite #150, San Jose, CA 95126, U.S.A. TEL: +1 408 944 4600 FAX: +1 408 321 3200 USA TECHREP COMPONENTS, INC. 25332 Narbonne Avenue, #160 Lomita, CA 90717, U.S.A. TEL: +1 310 539 9070 FAX: +1 310 539 0439 USA Jappe Company 29 Northgate Rd., Ipswich, MA 01938, U.S.A. TEL: +1 978 857 5611 USA Bay Advanced Technologies, LLC 1715 East Newport Circle Santa Ana, CA 92705, U.S.A. TEL: +1 657 622 2060 FAX: +1 657 622 2070 USA Marathon Technical Associates 1631 ROCK SPRINGS ROAD, PMB 355, APOPKA, FL 32712, U.S.A. TEL: +1 407 872 5775 USA Provoast Automation 1171 N. Red Gum Street Anaheim, CA 92806, U.S.A. TEL: +1 714 996 9417 FAX: +1 714 996 9418 USA Northport Engineering, Inc. 1355 Mendota Heights Road, Suite 130, Mendota Heights, MN 55120, U.S.A. TEL: +1 651 457 8000 FAX: +1 651 457 5603 USA Bay Advanced Technologies, LLC 8100 Central Avenue Newark, CA 94560-3449, U.S.A. TEL: +1 510 857 0900 FAX: +1 510 857 1400 USA Pinnacle Marketing, Inc. 2805 Spring Forest Road, Suite 101, Raleigh, NC 27616-1900, U.S.A. TEL: +1 888 764 7640 FAX: +1 888 764 7641 USA EASTERN INDUSTRIAL AUTOMATION 7096 South Willow Street Manchester, NH 03103, U.S.A. TEL: +1 603 645 6885 FAX: +1 603 668 1451 USA Straube Associates 7970 South Sheridan Blvd. Ste. C, Westminster, CO 80003, U.S.A. TEL: +1 303 426 0890 FAX: +1 303 426 0896 USA INDUSTRIAL AUTOMATION & MOTION INC. 4530 William Penn Highway #395 Murrysville, PA 15668, U.S.A. TEL: +1 412 965 9956 FAX: +1 412 245 1509 USA Synergy Sales INC 16 Hemlock Dr., Neptune, NJ 07753, U.S.A. TEL: +1 908 489 7764 FAX: +1 732 823 1907 USA NORTHEAST MOTION, INC. 20 Thurber Blvd. Unit #C Smithfield, RI 02917, U.S.A. TEL: +1 401 231 4441 FAX: +1 401 231 6785 USA Tech-Tron Sales, Inc 1305 Remington Road, Suite K, Schaumburg, IL 60173, U.S.A. TEL: +1 847 843 7530 FAX: +1 847 843 0339 USA TRILINE AUTOMATION CORP. 250 Summit Point Drive Henrietta, NY 14467, U.S.A. TEL: +1 585 321 9620 FAX: +1 585 321 9628 USA My Digital Link, Inc. Rochester, NY 14609, U.S.A. TEL: +1 585 288 7002 USA CPU AUTOMATION 164 Westford Road, Unit 3 Tyngsbord, MA 01879, U.S.A. TEL: +1 978 226 1633 FAX: +1 978 226 1634 USA Westrep 400 N Tustin Avenue Suite #130 Santa Ana, CA 92705, U.S.A. TEL: +1 714 527 2822 FAX: +1 714 527 3868 USA SADDLE BROOK CONTROLS PO BOX 881 280 N Midland Avenue Saddle Brook, NJ 07663, U.S.A. TEL: +1 201 794 9588 USA SHEPHERD CONTROLS & ASS., INC. 203 S. Jupiter Road, Suite A Allen, TX 75002, U.S.A. Please see other locations at; http://www.shepherdcontrols.com/ TEL: +1 972 727 7300 FAX: +1 972 727 7363 USA DELTA SIGMA AUTOMATION 2125 Barrett Park Dr. Suite 110 Kennesaw, GA 30144, U.S.A. TEL: +1 770 975 3992 FAX: +1 770 874 0087 USA KIM CONTROLS, INC. 10045 Davenport St. Minneapolis, MN 55449, U.S.A. TEL: +1 763 780 2991 FAX: +1 763 780 9449 USA IOWA FLUID POWER 1610 Blairs Ferry Road NE, Cedar Rapids, IA 52402, U.S.A. Please see other locations at; http://www.iowafluid.com/ TEL: +1 800 333 7004 FAX: +1 319 395 7027 USA AUTOMATION PROCESS & CONTROLS (IL) 6323 North Avondale Suite 246, Chicago, IL 60631, U.S.A. Please see other locations at; http://www.apc-inc.com/ TEL: +1 773 763 8090 FAX: +1 773 467 0152 USA MARSHALL WOLF AUTOMATION 923 South Main Street, Algonquin, IL 60102, U.S.A. TEL: +1 800 325 9653 FAX: +1 847 658 0960 USA ENGINEERING ADVANTAGE INC. S84 W 19234 Enterprise Drive, Muskego, WI 53150, U.S.A. TEL: +1 262 971 1717 FAX: +1 262 971 1710 USA IN-POSITION TECHNOLOGIES 7403 W. Boston Street Chandler, AZ 85226, U.S.A. TEL: +1 480 893 8086 FAX: +1 877 478 3242 592 USA CAROLINA MOTION CONTROLS, INC. 1200 Woodruff Road, Suite H27 Greenville, SC 29607, U.S.A. TEL: +1 864 458 9988 FAX: +1 864 288 2190 USA ADVANCED MACHINE AUTOMATION 1024 11TH Court West Birmingham, AL 35204, U.S.A. TEL: +1 205 581 1234 FAX: +1 205 581 1222 USA ADAMS AIR & HYDRAULICS 7204 EAST Adamo Drive Tampa, FL 33619, U.S.A. TEL: +1 813 626 4128 FAX: +1 813 626 7808 USA INT'L POWER ASSOCIATION 7940 Silverton Avenue, #105 San Diego, CA 92126, U.S.A. TEL: +1 858 271 5996 USA GJ Associates, Inc. 11 Shepherd Hill Road Bedford, NH 03110, U.S.A. TEL: +1 603 644 3677 FAX: +1 978 461 0155 USA Baldwin technologies 4801 Telsa Dr., Suite G Bowie, MD 20715, U.S.A. TEL: +1 301 860 1930 FAX: +1 301 860 1937 USA Power Support Engineering, Inc. 18932 Adams Country Way Lutz, FL 33559, U.S.A. TEL: +1 813 909 1199 VIETNAM QuadRep Representative Office (HCM) No.88/4, Street No.18, Hiep Binh Chanh Ward, Thu Duc District, HCM City, S.R. Vietnam TEL: +84 8 3726 2981 FAX: +84 8 3726 2985 VIETNAM QuadRep Representative Office (Hanoi) No 699, Ngo Gia Tu Str, Long Bien District, Hanoi, Vietnam TEL: +84 9 3648 4282 VIETNAM ARKTAKE VIET NAM JOINT STOCK COMPANY 132 Vong Street, Phuong Liet Sub-dist, Thanh Xuan District, Hanoi, Vietnam TEL: +84 4 3767 9428 FAX: +84 4 3767 9450 VIETNAM DPCVietNam TRADING & SERVICE CO., LTD 27 Block B, Truong Son Street, Ward 15, District 10, HCMC, Vietnam TEL: +84 8 3977 1926 FAX: +84 8 3977 1935 Distributors VIETNAM NHON CORPORATION 40, 11 Street, Him Lam Residential Area, Binh Hung, Binh Chanh, Hcmc, Vitenam TEL: +84 8 5431 9266 FAX: +84 8 5431 9269 593 Sale Notice of Cooling Fan Set Models Ideal fan sizes selected for various control panels, automated machines, and power supply units. You can purchase everything necessary in one order without the need for searching for the fan peripherals. It makes fan replacements easy. Delivered in one package, it simplifies storage and maintenance. Set configuration items Fan Finger guards One order includes everything needed for operation. Plug cord Screws (with flat washer and spring washer) *Package image Hex nuts Instruction manual Plug cords are compliant with Electrical Appliance and Material Safety Law, but not UL/CSA certified. 594 595 Sale Notice of Cooling Fan Set Models Eco Products SANYO DENKI's ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste.The product units and packaging materials are designed for reduced environmental impact.We have established our own assessment criteria on the environmental impacts applicable to all processes,ranging from design to manufacture.Those products that satisfy the criteria are accredited as ECO PRODUCTS. https://www.sanyodenki.com 3-33-1 Minami-Otsuka, Toshima-ku, Tokyo 170-8451, Japan P.A. Paris Nord , 48 Allee des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France Poland Branch ul. Wodociagowa 56 30-205 Krakow, Polska 468 Amapola Avenue Torrance, CA 90501, U.S.A. Room 2106-2110, Bldg A, Far East International Plaza, No.319, Xianxia Road, Shanghai, 200051, China Beijing Branch Room1222, Tower B, Beijing COFCO Plaza, No.8 Jianguomennei Dajie, Dong Cheng District, Beijing 100005 China Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Road, TST East, Kowloon, Hong Kong N-711, 7F, Chia Hsin 2nd Bldg., No.96, Sec.2, Zhongshan N. Rd., Taipei 10449, Taiwan 988 Toa Payoh North, #04-08, Singapore 319002 Indonesia Representative Office Summitmas II 4th Floor, Jl. Jend. Sudirman Kav.61-62, Jakarta 12190, Indonesia Frankfurter Strasse 80-82, 65760 Eschborn, Germany 15F, KDB Building, 372, Hangang-daero, Yongsan-gu, Seoul, 04323, Korea Busan Branch 8F, CJ Korea Express Bldg., 119, Daegyo-ro, Jung-gu, Busan, 48943, Korea 2F 02-11, Shenzhen International Chamber of Commerce Tower, No.168 Fuhua 3 Road, Futian District, Shenzhen, 518048 China Tianjin Branch Room AB 16th Floor TEDA Building, No. 256 Jie Fang Nan Road, Hexi District, Tianjin 300042 China Chengdu Branch Room2105B, Block A, Times Plaza, 2 Zongfu Road, Jinjiang District, Chengdu, 610016 China 388 Exchange Tower, 25th Floor, Unit 2501-1, Sukhumvit Road, Klongtoey, Klongtoey, Bangkok 10110 Thailand #14 (Old No.6/3), Avenue Road, Nungambakkam, Chennai - 600034, Tamil Nadu, India TEL: +81 3 5927 1020 TEL: +33 1 48 63 26 61 TEL: +48 12 427 30 73 TEL: +1 310 783 5400 TEL: +86 21 6235 1107 TEL: +86 10 6522 2160 TEL: +852 2312 6250 TEL: +886 2 2511 3938 TEL: +65 6223 1071 TEL: + 62 21 252 3202 TEL: +49 6196 76113 0 TEL: +82 2 773 5623 TEL: +82 51 796 5151 TEL: +86 755 3337 3868 TEL: +86 22 2320 1186 TEL: +86 28 8661 6901 TEL: +66 2261 8670 TEL: +91 44 420 384 72 The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. Specifications are subject to change without notice. CATALOG No.C1088B001 '18.12.IT