DDU37F
MECHANICALLY VARIABLE
TTL DELAY LINE
(SERIES DDU37F)
FEATURES PACKAGES
Ideal for “Set and Forget” applications
Multi-turn adjustment screw (approx. 40 turns)
Input & output fully TTL interfaced & buffered
(10 T2L fan-out capability)
Resolution: As low as 0.12ns
Minimum delay (TD0): 6ns typical
Output rise time: 2ns typical
Min. input pulse width: 20% of maximum delay
Power dissipation: 230mW maximum
Operating temperature: 0° to 70°C (Commercial)
-55° to 125°C (Military)
Temperature coefficient: 100 PPM/°C
FUNCTIONAL DESCRIPTION
The DDU37F-series device is a mechanically variable, FAST-TTL interfaced
delay line. The signal input (IN) is reproduced at the tap output (OUT),
shifted by an amount which can be adjusted between TD0 and TD0+ TDVAR,
where TDVAR is given by the device dash number (See Table). The device
operates from a single 5V supply and is TTL interfaced, capable of driving up
to 10 TTL loads.
SERIES SPECIFICATIONS
Functional Diagram
GND
IN OUT
.565
MAX
1.750
.285
.020
Package Dimensions
.187
.125
.200
MIN
.430
.100
IN GND
NCOUTVCC
1.640
.100
.200
.100
.060
.060
d
a
ta
delay
devices, inc.
3
DDU37F
GNDIN
OUT NC
VCC
DDU37F-xx (Commercial)
DDU37F-xxM (Military)
xx = Dash number
PIN DESCRIPTIONS
IN Signal Input
OUT Fixed Output
VCC +5V
GND Ground
NC No connection
DASH NUMBER
SPECIFICATIONS
Part
Number
TDVAR
(ns)
DDU37F-25 15
DDU37F-30 20
DDU37F-40 30
DDU37F-50 40
DDU37F-60 50
DDU37F-70 60
DDU37F-80 70
DDU37F-100 90
DDU37F-120 100
DDU37F-150 130
DDU37F-200 170
Note: Other delay times
available on request
2008 Data Dela
y
Devices
Doc #01016 DATA DELAY DEVICES, INC. 1
1/11/2008 3 Mt. Prospect Ave. Clifton, NJ 07013
DDU37F
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The DDU37F tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 20% of the total delay and periods as
small as 40% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
Delay Devices if your application requires device
testing at a specific input condition.
POWER SUPPLY BYPASSING
The DDU37F relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VCC to GND,
located as close as possible to the VCC pin, is
recommended. A wide VCC trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MIN MAX UNITS NOTES
DC Supply Voltage VCC -0.3 7.0 V
Input Pin Voltage VIN -0.3 VDD+0.3 V
Storage Temperature TSTRG -55 150 C
Lead Temperature TLEAD 300 C 10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
High Level Output Voltage VOH 2.5 3.4 V VCC = MIN, IOH = MAX
VIH = MIN, VIL = MAX
Low Level Output Voltage VOL 0.35 0.5 V VCC = MIN, IOL = MAX
VIH = MIN, VIL = MAX
High Level Output Current IOH -1.0 mA
Low Level Output Current IOL 20.0 mA
High Level Input Voltage VIH 2.0 V
Low Level Input Voltage VIL 0.8 V
Input Clamp Voltage VIK -1.2 V VCC = MIN, II = IIK
Input Current at Maximum
Input Voltage
IIHH 0.1 mA VCC = MAX, VI = 7.0V
High Level Input Current IIH 20
µA VCC = MAX, VI = 2.7V
Low Level Input Current IIL -0.6 mA VCC = MAX, VI = 0.5V
Short-circuit Output Current IOS -60 -150 mA VCC = MAX
Output High Fan-out 25 Unit
Output Low Fan-out 12.5 Load
Doc #01016 DATA DELAY DEVICES, INC. 2
1/11/2008 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
DDU37F
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT: OUTPUT:
Ambient Temperature: 25oC ± 3oC Load: 1 FAST-TTL Gate
Supply Voltage (Vcc): 5.0V ± 0.1V Cload: 5pf ± 10%
Input Pulse: High = 3.0V ± 0.1V Threshold: 1.5V (Rising & Falling)
Low = 0.0V ± 0.1V
Source Impedance: 50 Max.
Rise/Fall Time: 3.0 ns Max. (measured
between 0.6V and 2.4V )
Pulse Width: PWIN = 1.5 x Total Delay
Period: PERIN = 10 x Total Delay
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
IN OUTOUT
TRIG
IN
TRIG
Test Setup
DEVICE UNDER
TEST (DUT) OSCILLOSCOPE
PULSE
GENERATOR
Timing Diagram For Testing
DRISE DFALL
PERIN
PWIN
TRISE TFALL
0.60.6 1.51.5
2.4 2.4
1.51.5
VIH
VIL
VOH
VOL
INPUT
SIGNAL
OUTPUT
SIGNAL
Doc #01016 DATA DELAY DEVICES, INC. 3
1/11/2008 3 Mt. Prospect Ave. Clifton, NJ 07013