SPECIFICATION
DRP-240-24 DRP-240-48
MODEL
DC�VOLTAGE
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
OUTPUT VOLTAGE ADJ.�RANGE
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
VOLTAGE�RANGE Note.5
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
OVER�TEMPERATURE
SAFETY STANDARDS
HARMONIC�CURRENT
SAFETY &
EMS�IMMUNITY
WORKING�TEMP.
WORKING��HUMIDITY
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER�LOAD
OVER�VOLTAGE
AC�CURRENT (Typ.)
24V 48V
10A 5A
0�~�10A 0�~�5A
240W 240W
80mVp-p 150mVp-p
24�~�28V 48�~�53V
1.0%
0.5% 0.5%
1.0%
1.0%
1.0%
85�~�264VAC����������120�~�370VDC
47�~�63Hz
84% 85%
54�~�60V
2.8A/115VAC����������1.4A/230VAC
COLD�START 27A/115VAC����������45A/230VAC
<3.5mA /�240VAC
105�~�150% rated�output�power
30�~�36V
Protection�type�: Constant�current�limiting,�recovers�automatically�after�fault�condition�is�removed
Protection�type�:�Shut�down�o/p�voltage,�re-power�on�to�recover
100 5 (TSW1)Detect�on�heat�sink�of�power�transistor
Protection�type�:�Shut�down�o/p�voltage,�recovers�automatically�after�temperature�goes�down
-10�~�+70 (Refer�to�output�load�derating�curve)
20�~�90%�RH�non-condensing
-20�~�+85 ,�10�~�95%�RH
0.03%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�60min.�each�along�X, Y,�Z�axes
105.5Khrs�min.������MIL-HDBK-217F�(25 )
125.5*125.2*100mm�(W*H*D)
1.2Kg;�12pcs/15.5Kg/1.2CUFT
File�Name:DRP-240-SPEC���2005-06-20
UL508, TUV�EN60950-1 ApprovedUL60950-1,
Compliance�to�EN55011,EN55022�(CISPR22)�Class�B
Compliance�to EN61000-3-2,-3
Compliance�to�EN61000-4-2,3,4,5,6,8,11,�ENV50204,�EN55024,�EN61000-6-2�(EN50082-2)�Heavy�industry�level,�criteria A
240W�Single�Output�Industrial�DIN�RAIL Power�Supply DRP-240 series
ENVIRONMENT
PROTECTION
EMI�CONDUCTION�&�RADIATION
EMC
(Note�4)
WITHSTAND�VOLTAGE
ISOLATION�RESISTANCE
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
800ms,�40ms 00ms,�40ms/230VAC����������8 /115VAC�at�full�load
24ms ms/230VAC����������24 /115VAC�at�full�load
RIPPLE�&�NOISE�(max.) Note.2
VOLTAGE�TOLERANCE Note.3
POWER�FACTOR (Typ.) 0.96/230VAC����������0.99/115VAC�at�full�load