www.recom-power.com REV.: 6/2018 ECO-1
Description
The RxxP2xxS_D series of DC/DC converters are certified to UL/CSA60950-1 and UL/CSA62368-1 as
well as IEC/EN62368-1 and EN61010-1. This makes them ideal for medical and safety applications
where approved isolation is required. The /X2 version has an input/output clearance of more than 9mm.
DC/DC Converter
2 Watt
SIP7
Single and Dual
Output
EN/IEC62368-1 certified
UL/CSA60950-1 certified
UL/CSA62368-1 certified
EN61010-1 certified
EN55032 compliant
E224736
RxxP2xx
Features
Unregulated
Converters
• Qualified with 65kV/µs @ common mode =1KV
• Isolation 6.4kVDC
• Optional continuous short circuit protection
• Unique transformer system
• Compact SIP7 package
• /X2 version with >9mm input/output clearance
• very low isolation capacitance
www.recom-power.com/eval-ref-boards www.recom-power.com/bier
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
(1) Load
(2)
[VDC] [VDC] [mA] [%] [µF]
RxxP23.3S (3,4) 5, 12, 15, 24 3.3 600 70 3300
RxxP205S (3,4) 5, 12, 15, 24 5 400 70 - 75 1200
RxxP209S (3,4) 5, 12, 15, 24 9 222 70 - 75 1200
RxxP212S (3,4) 5, 12,15, 24 12 167 70 - 75 680
RxxP215S (3,4) 5, 12, 15, 24 15 133 75 - 80 680
RxxP23.3D (3,4) 5, 12, 15, 24 ±3.3 ±300 70 ±1500
RxxP205D (3,4) 5, 12, 15, 24 ±5 ±200 70 - 75 ±470
RxxP209D (3,4) 5, 12, 15, 24 ±9 ±111 70 - 75 ±470
RxxP212D (3,4) 5, 12,15, 24 ±12 ±83 70 - 75 ±330
RxxP215D (3,4) 5, 12, 15, 24 ±15 ±66 75 - 80 ±330
Model Numbering
Notes:
Note3: add suffix „/X2“ for single output with alternative pinout
Note4: add suffix „/P“ for continous short circuit protection
Ordering Examples:
R05P205S/P = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection
R05P23.3D/P = 5V Input, 3.3V Output, Dual Output, Continous Short Circuit Protection
R05P205S/P/X2 = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection, Alternative Pinout
Pinout (3)
Protection (4)
Single or Dual
Input Voltage
Output Power
Output Voltage
R__P2 __ _/P/X2
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up
in under 1 second without damage to the converter