* * * * * * * Features Unregulated Converters Qualified with 65kV/s @ common mode =1KV Isolation 6.4kVDC Optional continuous short circuit protection Unique transformer system Compact SIP7 package /X2 version with >9mm input/output clearance very low isolation capacitance DC/DC Converter RxxP2xx Description The RxxP2xxS_D series of DC/DC converters are certified to UL/CSA60950-1 and UL/CSA62368-1 as well as IEC/EN62368-1 and EN61010-1. This makes them ideal for medical and safety applications where approved isolation is required. The /X2 version has an input/output clearance of more than 9mm. Selection Guide Part Number nom. Input Voltage [VDC] Output Voltage [VDC] Output Current [mA] Efficiency typ. (1) [%] max. Capacitive Load (2) [F] RxxP23.3S (3,4) 5, 12, 15, 24 3.3 600 70 3300 RxxP205S (3,4) 5, 12, 15, 24 5 400 70 - 75 1200 RxxP209S (3,4) 5, 12, 15, 24 9 222 70 - 75 1200 RxxP212S (3,4) 5, 12,15, 24 12 167 70 - 75 680 5, 12, 15, 24 15 133 75 - 80 680 RxxP23.3D (3,4) 5, 12, 15, 24 3.3 300 70 1500 RxxP205D (3,4) 5, 12, 15, 24 5 200 70 - 75 470 RxxP209D (3,4) 5, 12, 15, 24 9 111 70 - 75 470 (3,4) 5, 12,15, 24 12 83 70 - 75 330 RxxP215D (3,4) 5, 12, 15, 24 15 66 75 - 80 330 RxxP215S RxxP212D (3,4) Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter Model Numbering R__P2 __ _/P/X2 2 Watt SIP7 Single and Dual Output E224736 EN/IEC62368-1 certified UL/CSA60950-1 certified UL/CSA62368-1 certified EN61010-1 certified EN55032 compliant Input Voltage Output Power Output Voltage Pinout (3) Protection (4) Single or Dual Notes: Note3: add suffix /X2" for single output with alternative pinout Note4: add suffix /P" for continous short circuit protection Ordering Examples: R05P205S/P = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection R05P23.3D/P = 5V Input, 3.3V Output, Dual Output, Continous Short Circuit Protection R05P205S/P/X2 = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection, Alternative Pinout www.recom-power.com/eval-ref-boards www.recom-power.com REV.: 6/2018 www.recom-power.com/bier ECO-1 RxxP2xx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Input Voltage Range 0% Minimum Load (5) Internal Operating Frequency Output Ripple and Noise Max. 10% 20kHz (6) 50kHz 85kHz 20MHz BW 200mVp-p Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Note6: Measurements are made with a 0.1F MLCC across output (low ESR) PxxP205S and PxxP209S PxxP205D and PxxP209D 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 10 0 0 10 20 30 40 50 60 70 80 90 50 40 30 R05P205S and R12P205S R05P209S R12P209S 20 60 R05P205D and R12P205D R05P209D R12P209D 20 10 0 100 0 10 20 30 Output Load [%] 90 90 80 80 70 70 Efficiency [%] Efficiency [%] 100 60 50 40 30 10 20 30 40 50 60 70 80 90 100 70 80 90 60 50 40 30 R05P212S R12P212S R05P215S R12P215S 20 10 60 PxxP212D and PxxP215D 100 0 50 Output Load [%] PxxP212S and PxxP215S 0 40 R05P212D R12P212D R05P215D R12P215D 20 10 100 0 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy Line Regulation Load Regulation 5.0% max. low line to high line, full load 10% to 100% load 3.3, 5VDC 9, 12, 15VDC 1.2%/1% of Vin typ. 15% typ. 10% typ. continued on next page www.recom-power.com REV.: 6/2018 ECO-2 RxxP2xx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) Output Voltage [%] Tolerance Envelope +10% +5% +5% Typical L o ad Line Vnom -1.5% -5% 10 50 100 Load [%] Deviation vs. Load PxxP205D and PxxP209D 25 20 20 15 15 Deviation [%] Deviation [%] PxxP205S and PxxP209S 25 10 5 0 R05P205S R05P209S R12P205S R12P209S -5 -10 -15 0 10 20 30 10 5 0 R05P205D R05P209D R12P205D R12P209D -5 -10 40 50 60 70 80 90 -15 100 0 10 20 30 Output Load [%] 20 20 15 15 10 5 0 R05P212S R05P215S R12P212S R12P215S -10 -15 0 10 20 30 60 70 80 90 100 Output Load [%] www.recom-power.com 70 80 90 100 70 80 90 100 5 0 R05P212D R05P215D R12P212D R12P215D -10 50 60 10 -5 40 50 PxxP212D and PxxP215D 25 Deviation [%] Deviation [%] PxxP212S and PxxP215S 25 -5 40 Output Load [%] -15 0 10 20 30 40 50 60 Output Load [%] REV.: 6/2018 ECO-3 RxxP2xx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Type Value without Suffix "/P" with Suffix "/P" Short Circuit Protection (SCP) Isolation Voltage (7) I/P to O/P 1 second continuous tested for 1 second 6.4kVDC rated for 1 minute 3.2VAC/60Hz Isolation Resistance 15G min. Isolation Capacitance 1.5pF min. / 10pF max. Insulation Grade basic Notes: Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note8: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type ENVIRONMENTAL Parameter Condition Operating Temperature Range Value without derating @ free air convection (see graph) Operating Altitude -40C to +90C 2000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 MTBF +25C Single Dual 2113 x 10 hours 2434 x 103 hours +85C Single Dual 299 x 103 hours 334 x 103 hours according to MIL-HDBK-217F, G.B. 3 Derating Graph (@ Chamber and free air convection) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 95 Ambient Temperature [C] www.recom-power.com REV.: 6/2018 ECO-4 RxxP2xx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety E224736-A56-UL UL60950-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 60950-1, 2nd Edition, 2014 Audio/video, information and communication technology equipment. Safety requirements E224736-A56-UL UL62368-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 62368-1, 2nd Edition, 2014 Audio/video, information and communication technology equipment. Safety requirements ATTCB106076 IEC62368-1:2014, 2nd Edition EN62368-1:2014 +A11:2017 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 1: General Requirements PS080601010 EN61010-1:2010 RU-AT.49.09571 TP TC 004/2011 EAC RoHs 2+ RoHS-2011/65/EU + AM2015/863 EMC Compliance Condition Electromagnetic compatibility of multimedia equipment Emission requirements Standard / Criterion with external filter EN55032, Class A/B EMC Filtering Suggestions according to EN55032 Class A and Class B Component List Class A C3 C1 L1 +VIN 10F 100V MLCC +VOUT C1 C3 C3 - - Component List Class B C1 C2 C1 C1 L1 -V 10F 100V 10F 100V 470H choke IN C2 -VIN L1 +VIN L1 -VOUT MLCC MLCC +VOUT COM C3 2n2F 8kV-VOUT WE 744 045 120 Vishay HGZ222MBP DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB non-conductive black plastic, (UL94 V-0) silicon rubber compound, (UL94 V-0) FR4, (UL94 V-0) Package Dimension (LxWxH) 19.5 x 9.8 x 12.5mm Package Weight 4.3g typ. continued on next page www.recom-power.com REV.: 6/2018 ECO-5 RxxP2xx DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) embossed logo 9.8 Pin Connection Pin # Single 1 +Vin 2 -Vin 5 -Vout 6 No Pin 7 +Vout Marking 0.51 12.5 19.5 Tolerance: 0.250.05 4.10 0.50+0.10/-0.05 Dual +Vin -Vin -Vout Com +Vout /X2 +Vin -Vin No Pin -Vout +Vout xx.x= 0.5mm xx.xx= 0.25mm Recommended Footprint Details 3x2.54= 7.62 1.9 6 7 2.54 5 1 2 2.4 Bottom View 1 2 5 6 7 Top View 2.54 6x2.54= 15.24 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 22.3 x 12.0mm Packaging Quantity tube 25pcs Storage Temperature Range -55C to +125C Storage Humidity 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 6/2018 ECO-6