9460 Paired - Single-Pair Cable For more information please call 1-800-Belden1 See Put-ups and Colors Description: 18 AWG stranded (16x30) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil(R) shield (100% coverage), 20 AWG stranded TC drain wire, PVC jacket. PHYSICAL CHARACTERISTICS: CONDUCTOR: Number of Pairs 1 Total Number of Conductors 2 AWG 18 Stranding 16x30 Conductor Material TC - Tinned Copper INSULATION: Insulation Material PE - Polyethylene Nom. Insulation Wall Thickness .019 in. Lay Length 1.5 in. Twists/ft. 8 Pair Color Code Chart : Number 1 Color Black & Clear OUTER SHIELD: Outer Shield Material Trade Name Beldfoil(R) Outer Shield Type Tape Outer Shield Material Aluminum Foil-Polyester Tape Outer Shield %Coverage 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG 20 Outer Shield Drain Wire Stranding Stranded Outer Shield Drain Wire Conductor Material TC - Tinned Copper OUTER JACKET: Outer Jacket Material PVC - Polyvinyl Chloride Page 1 of 3 9460 Paired - Single-Pair Cable Outer Jacket Nominal Wall Thickness .030 in. OVERALL NOMINAL DIAMETER: Overall Nominal Diameter .230 in. MECHANICAL CHARACTERISTICS: Operating Temperature Range -20C To +60C UL Temperature Rating 60C (UL AWM Style 2092) Bulk Cable Weight 34.2 lbs/1000 ft. Max. Recommended Pulling Tension 70 lbs. Min. Bend Radius (Install) 2.25 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification CM CEC/C(UL) Specification CM AWM Specification UL Style 2092 (300 V 60C) EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N) Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 FLAME TEST: UL Flame Test UL1685 UL Loading PLENUM/NON-PLENUM: Plenum (Y/N) N ELECTRICAL CHARACTERISTICS: Nom. Characteristic Impedance 57 Ohms Nom. Inductance .18 H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz 29.8 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 44 pF/ft Nom. Conductor DC Resistance @ 20 Deg. C 6.5 Ohms/1000 ft Max. Operating Voltage - UL 300 V RMS (UL AWM Style 2092) Max. Recommended Current 5.2 Amps per conductor @ 25C NOTES: Notes PUT-UPS AND COLORS: Item Description The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is on the inside of foil shield. Put-Up (ft.) Ship Weight (lbs.) Page 2 of 3 Jacket Color Notes 9460 Paired - Single-Pair Cable 9460 060U1000 9460 060U500 Revision Number: 1 1 PR #18 LDPE FS PVC 1 PR #18 LDPE FS PVC U1000 36 CHROME U500 18.5 CHROME Revision Date: 01-09-2006 (c) 2005 Belden Wire & Cable Company All Rights Reserved. Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3