Current Transducer LF 1005-S IPN = 1000 A For the electronic measurement of currents: DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 16110 Electrical data IPN IPM RM Primary nominal current rms Primary current, measuring range @ 24 V Measuring resistance @ with 15 V with 24 V ISN KN VC IC @ 1000 A max @ 1200 A max @ 1000 A max @ 1500 A max 1000 0 .. 1500 TA = 70C TA = 85C RM min RM max RM min RM max 0 0 5 5 Secondary nominal current rms Conversion ratio Supply voltage ( 5 %) Current consumption ( 1 mA) 18 0 7 0 60.5 10 24 10 15 4 57.5 21 A A * Closed loop (compensated) current transducer using the Hall effect 200 mA 1 : 5000 15 .. 24 V 28 (@ 24 V) + IS mA Accuracy - Dynamic performance data X Accuracy @ IPN , TA = 25C Linearity error L 0.4 < 0.1 Typ IO IOM Offset current @ IP = 0, TA = 25C Magnetic offset current @ IP = 0 and specified RM, after an overload of 3 x IPN Temperature variation of IO - 10C .. + 85C - 40C .. - 10C IOT tr di/dt BW Response time 1) to 90 % of IPN step di/dt accurately followed Frequency bandwidth (- 1 dB) 0.3 % % Max 0.4 mA 0.2 0.5 0.8 mA mA mA <1 > 100 DC .. 150 Features s A/s kHz * Isolated plastic case recognized according to UL 94-V0. Advantages * * * * * * * Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability. Applications * AC variable speed drives and servo motor drives * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies (UPS) * Switched Mode Power Supplies (SMPS) * Power supplies for welding General data applications. TA TS RS Ambient operating temperature Ambient storage temperature Secondary coil resistance @ m Mass Standards Note : 1) TA = 70C TA = 85C - 40 .. + 85 C - 45 .. + 100 C 48 51 550 g EN 50178: 1997 Application Domain * Industrial. With a di/dt of 100 A/s. page 1/3 080715/9 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Current Transducer LF 1005-S Isolation characteristics Vd Vw Rms voltage for AC isolation test, 50 Hz, 1 mn Impulse withstand voltage 1.2/50 s 3.8 16 kV kV dCp dCl CTI Creepage distance Clearance distance Comparative Tracking Index (Group IIIa) Min 20.6 19.6 175 mm mm Application examples According to EN 50178 and CEI 61010-1 standards and following conditions: * Over voltage category OV 3 * Pollution degree PD2 * Non-uniform field EN 50178 CEI 61010-1 Rated isolation voltage Nominal voltage Single isolation 1500 V 2000 V Reinforced isolation 1000 V 1000 V dCp, dCI, V W Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. page 2/3 080715/9 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Dimensions LF 1005-S (in mm. 1 mm = 0.0394 inch) Bottom view Back view Front view Connection Top view Mechanical characteristics Remarks * General tolerance * Transducer fastening * IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed 0.5 mm 2 holes 5.3 mm 2 M5 steel screws Recommended fastening torque 4 Nm or 2.96 Lb. - Ft. or 4 holes 4.2 mm 4 M4 steel screws Recommended fastening torque 3.2 Nm or 2.37 Lb. - Ft. or 4 holes 2.25 mm depth10 mm 4 x PT KA30 screws long 10 mm Recommended fastening torque 0.9 Nm or 0.66 Lb. - Ft. * Transducer fastening Horizontal position 4 holes 5.3 mm 4 M5 steel screws Recommended fastening torque 4 Nm or 2.96 Lb. - Ft. or 4 holes 2.25 mm depth16 mm 4 x PT KA30 screws long 16 mm Fastening torque, maxi 1 Nm or 0.74 Lb. - Ft. * Primary through-hole 40.5 x 13 mm or 38 mm * Connection of secondary Molex 6410 3 Tin plated pins. Vertical position 100C. * Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. * This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. page 3/3 080715/9 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com