SPECIFICATION
120W PWM Output LED Driver PWM-120 series
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.5
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
12V 24V 36V 48V
10A 5A 3.4A 2.5A
120W 120W 122.4W 120W
0 ~ 100%
1.47kHz for Blank/DA-Type, 2.5kHz for DA2-Type
500ms, 80ms/ 230VAC or 115VAC
16ms/230VAC or 115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.93/277VAC @ full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
88% 90% 90% 90.5%
<0.25mA / 277VAC
108 ~ 130% rated output power
Hiccup mode, recovers automatically after fault condition is removed
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 45℃,except 0 ~ 40℃ for 12V)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
860.4K hrs min. Telcordia SR-332 (Bellcore) ; 228.7K hrs min. MIL-HDBK-217F (25℃)
191*63*37.5mm (L*W*H)
℃
℃
℃℃
※ : , https://www.meanwell.com/serviceDisclaimer.aspx
Shut down o/p voltage, re-power on to recover
DIMMING RANGE
PWM FREQUENCY (Typ.)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V
1.3A / 115VAC 0.65A / 230VAC 0.55A / 277VAC
PWM-120-12 PWM-120-24 PWM-120-36 PWM-120-48
WITHSTAND VOLTAGE
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC IMMUNITY
Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020
EMC EMISSION Note.6
COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ; Per NEMA 410
TOTAL HARMONIC DISTORTION
0.97Kg; 15pcs/15.6Kg/0.87CUFT
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
SHORT CIRCUIT
(Please refer to "STATIC CHARACTERISTIC" section)
THD< 20%(@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION” section)
No load power consumption<0.5w for blank-type;standby power consumption<0.5W for DA-type/DA2-type
Tcase=-40 ~ + (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)90℃
Tcase=+90℃
MAX. CASE TEMP.
UL8750( type ”HL” )(except for 12DA type), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13, EN62384 independent,
IP67,BIS IS15885( for PWM-120-12,24 only), EAC TP TC 004,GB19510.1,GB19510.14 approved; Design refer to EN60335-1;
According to EN61347-2-13 appendix J suitable for emergency installations
12V/24V hiccup mode and 36V/48V shut down mode(including DA-type/except for DA2-type)
DALI STANDARDS IEC62386-101, 102, 207,251 for DA/DA2-Type only, Device type 6(DT6)
NO LOAD/STANDBY
POWER CONSUMPTION
File Name:PWM-120-SPEC 2021-04-1
Hiccup mode,recovers automatically after fault condition is removed (only for DA2-type)
Note.2
Note.9
I/P-O/P:3.75KVAC; I/P-DA:1.5KVAC; O/P-DA:1.5KVAC