WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
IP67
THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL CLG-100-12 CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48
DC VOLTAGE
RATED CURRENT Note.5
RATED POWER Note.5
OUTPUT VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT (Typ.)
OVER VOLTAGE
OVER TEMPERATURE
12V
9 ~ 12V
15V
11.25 ~ 15V
20V
15 ~ 20V
24V
18 ~ 24V
27V
20.25 ~ 27V
36V
27 ~ 36V
48V
36 ~ 48V
5A 5A 4.8A 4A 3.55A 2.65A 2A
60W 75W 96W 96W 95.85W 95.4W 96W
150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
Fixed. Can be modified between 0% ~ -15% rated output voltage
Fixed. Can be modified between 3% ~ -25% rated output current
±1.0%
±2.0%
500ms, 80ms / 230VAC 1200ms, 80ms / 115VAC at full load
60ms / 230VAC 30ms / 115VAC at full load
90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 52 ~ 64V
COLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 240VAC
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
301Khrs min. MIL-HDBK-217F (25 )
222.2*68*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
7. lease refer to "DRIVING METHODS OF LED MODULE".
P
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
1.0Kg; 12pcs/13Kg/0.58CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100W Single Output Switching Power Supply
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency up to 88.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
IP67 design for indoor or outdoor installations
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty (Note.6)
Features :
CLG-100 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
MM
110 LPS
SELV
CONSTANT CURRENT REGION
Note.7
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55015, EN55032 Class B, EN61000-3-2 Class C ( 75% load) ;
EN61000-3-3,GB17743 and GB17625.1 EAC TP TC 020
,
EMC IMMUNITY
EMC EMISSION
83% 85% 88.5% 88.5% 88% 88% 88.5%
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
No.223-M91(except for 48V), CAN/CSA C22.2 No. 250.13-12, ,EAC TP TC 004GB19510.1,GB19510.14, P67J61347-1, J61347-2-13 I approved ;,
U 879, UL1310, UL8750, CSA C22.2 No. 207-M89, 61347-1, 61347-2-13 independent, TUV EN60950-1,CAN/CSA C22.2lEN/AS/NZS EN/AS/NZS
File Name:CLG-100-SPEC 2018-01-09
S
&
E
( except for 48V )for UL1310
(all models)for UL8750 and UL879
( for 48V only)
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
design refer to UL60950
NRND
Mechanical Specification
File Name:CLG-100-SPEC 2018-01-09
Case No. 954A Unit:mm
Fosc : 100KHz
Derating Curve Static Characteristics
LOAD (%)
-30 -25 -10 0 15 30 50 60 70
20
40
60
80
100
90 100 125 135 145 155 165 175 180 200 230 295
100
90
80
70
60
50
40
LOAD (%)
(HORIZONTAL)
DETECTION
PWM & PFC CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
230VAC
Input only
AMBIENT TEMPERATURE ( )INPUT VOLTAGE (V) 60Hz
99.1
T case
34
T case: Max. Case Temperature.
100W Single Output Switching Power Supply CLG-100 series
Block Diagram
300 20±
FG (Green/Yellow)
38.8
222.2
198.2
AC/L(Brown)
AC/N(Blue)
12
9.6
9.49.4 34.2
68
ψ×4.2 4PL
300 20±
SJOW 17AWG H05RN-F 1.0mm 2C²
SJOW 17AWG&
-V(Blue)
+V(Brown)
H05RN-F 1.0mm 3C²×
NRND
0.76
0.78
0.80
0.82
0.84
0.86
0.88
0.90
0.92
0.94
0.96
0.98
1.00
50% 60% 70% 80% 90% 100%
115V
230V
277V
68
70
72
74
76
78
80
82
84
86
88
90
92
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
115V
230V
277V
CLG-100 series possess superior working efficiency that up to 88.5% can be reached in field applications.
EFFICIENCY (%)
LOAD
Power Factor Characteristic
EFFICIENCY vs LOAD (48V Model)
Constant Current Mode
PF
LOAD
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
DRIVING METHODS OF LED MODULE
(100W)
File Name:CLG-100-SPEC 2018-01-09
100W Single Output Switching Power Supply CLG-100 series
Typical LED power supply I-V curve
Vo(%)
100
75
50 100
(min.)
Io (%)
Constant
Current area
Hiccup
Protection
Constant
Voltage area
(A) (B)
(C)
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
NRND