Loose Tube Cable Non-Armored Design
SAMSUNG Loose Tube Non-Armored Cable (SC-LMN 100/
2 0 0 ) offers highly reliable, industry standard performance
and accommodates the flexible and versatile needs for
outside plant cables for today’s most demanding and
diverse fiber optics marketplace. This cable is designed to
ensure superior mechanical and environmental
characteristics and suitable for duct aasdfnd aerial applications
in real world installations.
FEATURES / BENEFITS
• Fiber counts up to 432
• 1~12 fibers per gel filled buffer tube
• High tensile strength design
• Easy mid-span access
• Dry core water blocking design (SC-LMN 200)
• Gel-filled water blocking design (SC-LMN 100)
• Suitable for duct or aerial installation
• Colored fibers and buffer tubes for quick identification
• UV-resistant outer jacket
• Robust yet easy-to-strip Medium Density PE outer jacket
• High fiber count to diameter ratio
• Complies with Telcordia GR-20-CORE, and TIA/EIA
standards
• Custom designs are available on request
APPLICATIONS
• Long Haul and Metropolitan Area Network
• Inter-Office Trunking and Supertrunking
• Local Loop / Feeder
• Distribution
Central Strength Member
Water Absorbent Yarn
Optical Fiber
Water Blocking Gel
Loose Tube
Water Absorbent Tape
Peripheral Strength Member (Optional)
Rip Cord
Polyethylene Jacket
Loose Tube Cable
(Non-Armored Design)
SC-LMN100/200
1
Samsung Fiberoptics Products
CABLE WEIGHT & DIAMETER
mm inch kg/km lbs/1000 ft km ft
LMN-NM2S-006-T67G 6 6 1 6 11.7 0.461 115 77 6 20,000
LMN-NM2S-012-T67G 12 6 1 6 11.7 0.461 115 77 6 20,000
LMN-NM2S-018-T67G 18 6 1 6 11.7 0.461 115 77 6 20,000
LMN-NM2S-024-T67G 24 6 1 6 11.7 0.461 115 77 6 20,000
LMN-NM2S-030-T67G 30 6 1 6 11.7 0.461 115 77 6 20,000
LMN-NM2S-036-T67G 36 6 1 6 11.7 0.461 115 77 6 20,000
LMN-NM2S-048-TB7G 48 12 1 6 12.6 0.496 131 88 6 20,000
LMN-NM2S-060-TB7G 60 12 1 6 12.6 0.496 131 88 6 20,000
LMN-NM2S-072-TB7G 72 12 1 6 12.6 0.496 131 88 6 20,000
LMN-NM2S-084-TB7G 84 12 1 8 14.3 0.563 131 88 6 20,000
LMN-NM2S-096-TB7G 96 12 1 8 14.3 0.563 131 88 6 20,000
LMN-NM2S-108-TB7G 108 12 1 10 16.1 0.634 206 138 6 20,000
LMN-NM2S-120-TB7G 120 12 1 10 16.1 0.634 206 138 6 20,000
LMN-NM2S-132-TB7G 132 12 1 12 17.9 0.705 251 169 6 20,000
LMN-NM2S-144-TB7G 144 12 1 12 17.9 0.705 251 169 6 20,000
LMN-NM2S-156-TB7G 156 12 2 18(6/12) 18.4 0.724 255 171 6 20,000
LMN-NM2S-168-TB7G 168 12 2 18(6/12) 18.4 0.724 255 171 6 20,000
LMN-NM2S-180-TB7G 180 12 2 18(6/12) 18.4 0.724 255 171 6 20,000
LMN-NM2S-192-TB7G 192 12 2 18(6/12) 18.4 0.724 255 171 6 20,000
LMN-NM2S-204-TB7G 204 12 2 18(6/12) 18.4 0.724 255 171 6 20,000
LMN-NM2S-216-TB7G 216 12 2 18(6/12) 18.4 0.724 255 171 6 20,000
LMN-NM2S-288-TB7G 288 12 2 24(9/15) 21.0 0.827 332 223 5 16,700
LMN-NM2S-432-TB7G 432 12 3 36(6/12/18) 24.2 0.953 437 294 3 10,000
* Diameter and weight are subject to change without prior notice
Item Number Fibers
per
Tube
Fibers Layer
Number
Unit
Number
Nom. Outer Dia. Nom. Weight Max. Reel
Length
MECHANICAL & ENVIRONMENTAL CHARACTERISTICS
Item Number Max. Load Min. Bending Radius Temperature Crush Impact Water
Resistance Resistance Penetration
(N) (mm) (˚C) (N) (Impacts) (m)
Installing Operating Installing Operating Installing Operating ( /100 mm) (@ 3 N.m) ( /24 hrs)
LMN-NM2S-XXX-TB7G 2700 1000 20 x Dia. 10 x Dia. -30 ~ +60 -40 ~ +70 2200 20 1
2
Loose Tube Cable
Non-Armored Design
Samsung Electronics Fiberoptics products
1Sheath Construction
L: LAP Sheath (AP) N: Single Jacket (P)
D: Double Jacket (PYP) X: Others
Note) The letters in parenthesis contain specific information on sheath materials.
Each letter from the left denotes corresponding material used for cabling
from inside to an outward direction according to the match below.
A: Laminated Aluminum Tape P: Polyethylene
Y: Yarn (Glass, Aramid)
2Sheath Material
M: MDPE H: HDPE Z: LSZH F: Flame Retardant PE
3Central Member
SC - LMN100 : Gel - filled
0: Metallic 1: Dielectric
SC - LMN200 : Dry - core
2: Dielectric 3: Metallic
4Fiber Type
S: SMF M: MM50/125 L: MM62.5/125
N: NZDSF H: Hybrid
6Max. Attenuation
T: 0.35/0.25 dB/km (1310/1550 nm, SMF)
A: 0.40/0.30 dB/km (1310/1550 nm, SMF)
M: 2.5/0.7 dB/km & 500/500 MHz-km (850/1300 nm, MM50/125)
H: 2.7/0.8 dB/km & 500/500 MHz-km (850/1300 nm, MM50/125)
L: 3.0/0.8 dB/km & 160/500 MHz-km (850/1300 nm, MM62.5/125)
C: 3.2/1.0 dB/km & 160/500 MHz-km (850/1300 nm, MM62.5/125)
N: 0.25 dB/km (1550 nm, NZDSF)
7Fibers in Tube
2: 2 fibers 4: 4 fibers 6: 6 fibers 8: 8 fibers
B: 12 fibers
8Tensile Load
5 : 1500 N 7 : 2700 N 3 : 3500 N X : special
9Peripheral Strength Member
N : None G : Glass Yarn Y : Aramid Yarn
ORDERING INFORMATION 321 4 6 7 8 9
X X X
LMN
SAMSUNG STANDARD : LMN - NM2S - XXX - TB7G
• Loose Tube Design, Single Jacket Non - Armored Cable
• Dry core, Dielectric strength member (FRP + Glass Yarn)
• Tensile load : Max. 2700 N
Fiber Counts
Samsung Electronics Fiberoptics Division
7th Floor, Samsung Main Building 250, 2-Ga,
Taepyung-Ro, Chung-Gu, Seoul, Korea 100-742
Tel: +82-2-751-2529 Fax: +82-2-751-2687
e-mail: fiberoptics@samsung.com
Samsung Telecommunications America
1130E, Arapaho Road, Richardson, TX 75081
Toll Free Number: 1-877-ssoptic/1-877-776-7842
Fax: 1-972-761-7349
3
Loose Tube Cable
Non-Armored Design