07-2015, Rev. 0715
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
AXICOM
Signal Relays
n Multi purpose relay
n Small size permitting high packing density
n 1 form C contact (1 CO, 1 changeover contact)
n 200mW and 450mW coils
n 1A and 3A contacts
n High shock resistance of 30g
n Ambient temperature for sensitive version up to 85°C
n Immersion cleanable
Typical applications
Security devices, electric door openers, duplex intercommunication
systems, measurement and controls
Approvals
UL 508 File No. E 111441
Technical data of approved types on request
Contact Data 1.25A 3A
Contact arrangement 1 form C (CO)
Max. switching voltage 120VDC, 125VAC
Rated current 1.25A 3A
Limiting continuous current, 85°C 1.25A 3A
Switching power 30W, 62.5VA 72W, 360VA
Contact material AgPd, gold plated AgNi
AgNi, gold plated
Min. recommended contact load 10mA at 20 mV
Minimum switching voltage 100μV
Initial contact resistance 100mΩ at 10mA, 20mV
Frequency of operation, without load max. 20 operations/s
Operate / release time max. 7ms/5ms
Bounce time max., form A/form B 2/10ms
Electrical endurance,
standard version
at 24VDC / 1.25A min. 3x105 ops.
at 24VDC / 3A min. 2x105 ops.
at 120VAC / 1.25A min. 1.5x105 ops.
at 120VAC / 3A min. 4x105 ops.
sensitive version
at 24VDC / 1.25A min. 2x105 ops.
at 24VDC / 3A min. 1x105 ops.
at 120VAC / 1.25A min. 1x105 ops.
at 120VAC / 3A min. 3x105 ops
Mechanical endurance typ. 10x106 operations
Coil Data
Magnetic system neutral
Coil voltage range 1.5 to 24VDC
Max. coil temperature 130°C
Thermal resistance < 125K/W
Coil versions, monostable
Coil Rated Operate Limiting Release Coil Rated coil
code voltage voltage Voltage voltage resistance power
VDC VDCmin. VDCmax. VDCmin. Ω±10% mW
Standard coil, 450mW
001 1.5 1.3 2.6 0.15 6 375
002 3 2.1 4.7 0.30 20 450
003 5 3.5 7.9 0.50 56 446
004 6 4.2 9.5 0.60 80 450
005 9 6.3 14.2 0.90 180 450
006 12 8.4 19.0 1.20 320 450
007 24 16.8 38.0 2.40 1280 450
Sensitive coil, 200mW
101 1.5 1.1 3.6 0.15 12 188
102 3 2.3 7.1 0.30 45 200
103 5 3.8 11.6 0.50 120 208
104 6 4.5 14.2 0.60 180 200
105 9 6.8 21.2 0.90 400 203
106 12 9.0 28.0 1.20 700 206
107 24 18.0 56.0 2.40 2800 206
108 18 13.5 33.0 1.80 1620 200
All figures are given for coil without pre-energization, at ambient temperature +23°C.
W11 Relay V23101
108-98010 Rev. C
All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 13
Telecom-, Signal and RF Relays
W11 Relay V23101
AXICOM
Contact Data
Number of contacts and type 1 changeover contacts
Contact assembly single contacts
Contact material AgPd, gold plated
AgNi, gold plated
AgNi
Limiting continuous current at max. ambient temperature 1.25 A3 A
Maximum switching current (see load limit diagram) 1.25 A3 A
Maximum swichting voltage 120 Vdc
125 Vac
120 Vdc
125 Vac
Maximum switching capacity 30 W / 62.5 VA 72 W / 360 VA
Thermoelectric potential < 10 µV < 10 µV
Initial contact resistance / measuring condition: 10 mA / 20 mV 100 mΩ 100 mΩ
Electrical endurance
standard: at 24 Vdc / 1.25 A
at 24 Vdc / 3 A
at 120 Vac / 1.25 A
at 120 Vac / 3 A
min. 3 x 105 operations
min. 1.5 x 105 operations
min. 2 x 105 operations
min. 4 x 105 operations
sensitive: at 24 Vdc / 1.25 A
at 24 Vdc / 3 A
at 120 Vac / 1.25 A
at 120 Vac / 3 A
min. 2 x 105 operations
min. 1 x 105 operations
min. 1 x 105 operations
min. 3 x 105 operations
Mechanical endurance, typ 107 operations
Max. DC Load Breaking Capacity
DC Voltage [Vdc]
DC current [A]
Max. DC load breaking capacity
108-98010 Rev. C
All specifications subject to change. Consult Tyco Electronics for latest specifications. 8 of 13
Telecom-, Signal and RF Relays
W11 Relay V23101
AXICOM
Unom = Nominal coil voltage
Umax. = Upper limit of the operative range of
the coil voltage (limiting voltage)
Uop. min. = Lower limit of the operative range of the
coil voltage (reliable operate voltage)
For latching relays Uset min. resp. Ureset min.
Urel. min. = Lower limit of the operative range of
the coil voltage (reliable release voltage)
Coil Operating Range
Unom. nominal coil voltage
Uop. min.
Urel. min.
Umax. at 0 A
Umax. at 1.25 A
Ambient Temperature [°C]
Coil Voltage [U/Unom]
200 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
-40-30 -20-10 0102030405060708090100
Unom. nominal coil voltage
Uop. min.
Urel. min.
Umax. at 0 A
Umax. at 1.25 A
Ambient Temperature [°C]
Coil Voltage [U/Unom]