SSG SSG
102
Precautions
Mounting
Use two 2.2 mounting screws with spring washers to mount the
switch. Tighten the screws to a torque of 0.20 to 0.25 N S m (2 to
2.5 kgf
S cm).
Mounting Holes
9.5±0.1
The
switch does not have a ground terminal. The minimum
distance
through insulation
(IEC1058-1) is 0.9 mm. If proper insulation for the
end
product cannot be secured, additional insulation such as a sep
-
arator
or insulation cover should be attached.
Soldering
When soldering switch terminals, apply a soldering iron rated at
60 W
max. and finish soldering quickly within 3
seconds. During sol
-
dering and 1 minute after soldering, do not apply external force to
the
terminals.
Solder terminal is provided with a hole so that a conductor can be
secured mechanically
.
The
conductors
for a soldering terminal (H type) should be flexible
and
its cross section should be A
WG18 to 20 for the SSG-5H Series
and
A
WG20 to 22 for the SSG-01H Series.
To
automatically solder the
switch to a PCB in a soldering bath, com
-
plete
soldering within 5 seconds
at a flux temperature of 250
°
C and
avoid the overflow of flux onto the surface of the PCB where the
switch
or other parts are mounted.
Actuating
Make sure that the operating speed and frequency are within the
permissible
range of the switch.
1. Do not use the switch in an application where the operating
speed is extremely slow or the switching operation could
become unstable or malfunctioning could result due to
contact
failure or contact welding.
2. Do not use the switch in an application where the operating
speed
is too fast, or the switch will be broken
due to a shock or
the
movable contact will not keep up with the speed.
The
reliability of a switch is maintained within the permissible oper
-
ating
speed and frequency of the switch. The life of a switch is deter
-
mined
at a specified operating
speed, therefore, it varies with the ac
-
tual
operating speed and frequency
.
The
switch should be set so that its stroke will be in the range of 60%
to
90% of the rated OT when the switch is operated. The stroke must
not
exceed the rated OT value.
Malfunctioning
can result if the switch is set with its stroke exceed
-
ing
the rated OT
. Therefore the proper adjustment of the
mounting
position
is essential when installing the switch.
Do
not apply excessive force to the actuator
. Be very careful not to
apply
force in
the opposite and lateral directions relative to the oper
-
ating
direction.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
convert millimeters into inches, multiply by 0.03937. T
o convert grams into ounces, multiply by 0.03527.
Cat. No. B096-E1-1