Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8434 Multi-Conductor - Special Audio, Communication and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 25 AWG stranded (7x33) tinned copper/tinned copper covered steel conductors, polyethylene insulation, overall Beldfoil(R) shield (100% coverage), 25 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 2 25 7x33 3 strands tinned copper + 4 strands tinned copper covered steel Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PE - Polyethylene 0.381 Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape w/Shorting Fold (foil side out) 100.000 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape (foil side in) 100.000 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 25 7 x 33 awg 3 strands tinned copper + 4 strands tinned copper covered steel Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.508 Overall Cable Overall Nominal Diameter: 4.191 mm Pair Pair Color Code Chart: Number Color 1 Shielded: Red & Black 2 Unshielded: Green & White Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C Non-UL Temperature Rating: 80C Bulk Cable Weight: 17.858 Kg/Km Max. Recommended Pulling Tension: 182.376 N Min. Bend Radius/Minor Axis: 44.450 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 2 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8434 Multi-Conductor - Special Audio, Communication and Instrumentation Cable EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.6562 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 82.025 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 131.24 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 149.286 Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 62.011 Ohm/km Max. Operating Voltage - Non-UL: Voltage 400 V RMS Max. Recommended Current: Current 1.3 Amps per conductor @ 25C Notes (Overall) Notes: Red and Black pair 100% Beldfoil(R) shielded (foil side out in contact with drain wire). 3 copper, 4 copper-covered steel strands in each conductor. Put Ups and Colors: Item # Putup Ship Weight Color 8434 060U1000 1,000 FT 14.000 LB CHROME 8434 060100 100 FT 2.000 LB CHROME 8434 0601000 1,000 FT 14.000 LB CHROME 8434 060500 500 FT 7.000 LB CHROME Notes Item Desc 4 #25 PE SH PVC 4 #25 PE SH PVC C 4 #25 PE SH PVC 4 #25 PE SH PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 11-13-2012 (c) 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 2 of 2 01-09-2015