Fluke Connect with ShareLive is the only wireless measurement system
that lets you stay in contact with your entire team without leaving
the field. The Fluke Connect mobile app is available for Android™ (4.3
and up) and iOS (4s and later) and works with over 20 different Fluke
productsthe largest suite of connected test tools in the world. And
more are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all
temperature, mechanical, electrical and vibration measurements for
each equipment asset in one place. Get started saving time and
increasing your productivity.
Download the app at:
Technical Data
Fluke 1555 and
1550C Insulation
Resistance Testers
Evaluate the trends, eliminate the doubt
The Fluke 1555 and Fluke 1550C insulation
resistance testers, offer digital insulation testing up to
10 kV, making them ideal for testing a wide range of
high voltage equipment including switchgear, motors,
generators and cables.
Fluke insulation testers can now conduct the
entire range of test voltages specified in IEEE
43-2000 with a best in class, 3 year
warranty and CAT IV 600 V safety rating. With
measurement storage and PC interface, the 1555 and
1550C are perfect tools for preventative or predictive
maintenance programs designed to identify potential
equipment failures before they occur.
The Fluke Connect mobile app is an easy to use,
advanced wireless system for capturing and trending
anomalies for troubleshooting, commissioning and
preventative maintenance of insulation resistance
applications.
Features include:
Test voltages to up 10 kV and save time by
trending on the spot only with Fluke Connect
CAT III 1000 V, CAT IV 600 V safety rating
Warning function alerts the user that line voltage
is present and gives the voltage reading up to 600
V ac or dc for increased user safety
Selectable test voltages in 50 V steps from 250 V
to 1000 V, and 100 V steps above 1000 V
Measurements can be stored in up to 99 memory
locations, with each location assigned a unique,
user defined, label for easy recall
Long battery life gives the user over 750 tests
between charges
Automatic calculation of Dielectric Absorption
(DAR) and Polarization Index (PI) with no
additional setup
Guard system eliminates the effect of surface
leakage current
on high-resistance measurements
Large digital/analog LCD for easy viewing
Capacitance and leakage current measurement
Ramp function for breakdown testing
Resistance measurements up to 2TΩ
Timer settings up to 99 minutes for timed tests
3-year warranty
Now compatible with Fluke
Connect
Mobile App
Built with
See it. Save it. Share it.
All the facts, right in the field.
Smart phone not included with purchase.
1.888.610.7664 info@Fluke-Direct.com
Fluke-Direct
.com
2 Fluke Corporation Fluke 1555 and 1550C Insulation Resistance Testers
1550C 5 kV Insulation Tester
1555 10 kV Insulation Tester
1550C/Kit 5 kV Insulation Tester Kit
1555/Kit 10 kV Insulation Tester Kit
Optional accessories
TL1550EXT 25 foot extended
test lead set
TLK1550-RTLCT Heavy Duty Alligator
Clip leads
FLUKE-IR3000FC1550 Fluke Connect
IR to Wireless Connector
Included accessories
Test Cables with Alligator Clips
(red, black, green)
Infrared adapter with interface cable
FlukeView Forms Basic CD-ROM
AC Power Cord
Soft Carrying Case (base models only)
English Manual
Users Manual on CD-ROM
Quick Reference Card
Software License Agreement
Registration Card
FlukeView Forms Installation Guide
USB-IR Cable Installation Guide
IP67 Hard Case (kit only)
Certificate of Calibration (kit only)
Heavy Duty Alligator Clip Leads
(kit and 1555 only)
Fluke Connect IR to Wireless Connector
(kit only)
Software specifications
Fluke ViewForms basic software
requires a PC running Windows XP,
Windows Vista , Windows 7 and
Windows 8.
Electrical specifications
The tester’s accuracy is specified for one year after calibration at operating
temperatures of 0 °C to 35 °C. For operating temperatures outside the range
(-20 °C to 0 °C and 35°C to 50 °C), add ± .25 % per °C, except on the 20 % bands
add ± 1 % per °C.
Insulation resistance measurement
Test voltage (dc) Range Accuracy (± reading)
250 V < 200 kΩ
200 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 GΩ
unspecified
5 %
20 %
unspecified
500 V < 500 kΩ
500 kΩ to 10 GΩ
10 GΩ to 100 GΩ
> 100 GΩ
unspecified
5 %
20 %
unspecified
1000 V < 200 kΩ
200 kΩ to 20 GΩ
20 GΩ to 200 GΩ
> 200 GΩ
unspecified
5 %
20 %
unspecified
2500 V < 200 kΩ
200 kΩ to 50 GΩ
50 GΩ to 500 GΩ
> 500 GΩ
unspecified
5 %
20 %
unspecified
5000 V < 200 kΩ
200 kΩ to 100 GΩ
100 GΩ to 1 TΩ
> 1 TΩ
unspecified
5 %
20 %
unspecified
10000 V (1555 Only) < 200 kΩ
200 kΩ to 200 GΩ
200 GΩ to 2 TΩ
> 2 TΩ
unspecified
5 %
20 %
unspecified
Bar graph range 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
Insulation test voltage accuracy -0 %, +10 % at 1 mA load current
Induced ac mains current rejection 2 mA maximum
Charging rate for capacitive load 5 seconds per μF
Discharge rate for capacitive load 1.5 s/μF
Range Accuracy
Leakage current
measurement
1 nA to 2 mA ± (5 % + 2 nA)
Capacitance measurement 0.01 uF to 15.00 μF ± (15 % rdg + 0.03 μF)
Timer Range Resolution
0 to 99 minutes Setting: 1 minute
Indication: 1 second
Live circuit warning Warning range Voltage accuracy
30 V to 660 V ac/dc, 50/60 Hz ± (15 % + 2 V)
General specifications
Display 75 mm x 105 mm
Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC) 85 V to 250 V ac 50/60 Hz 20 VA
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal
(ground pin) is not connected internally. The extra pin is for added plug retention only.
Dimensions 269 mm x 277 mm x 160 mm (10.6 in x 10.9 in x 6.3 in)
Weight 3.7 kg (8.2 lb)
Temperature (operating) -20 ºC to 50 ºC (-4 ºF to 122 ºF)
Temperature (storage) -20 ºC to 65 ºC (-4 ºF to 149 ºF)
Humidity 80 % to 31 ºC decreasing linearly to 50% at 50 ºC
Altitude 2000 m
Enclosure sealing IP40
Input overload protection 1000 V ac
Electromagnetic compatibility EN 61326
Certifications
Safety compliance IEC 61010-1: Overvoltage categroy II, pollution degree 2.
IEC 61010-2-030: Measurement 600V CAT IIV / 1000V CAT III
IEC 61557-1, IEC 61557-2