2
White Electronic Designs Corporation • Phoenix, AZ • (602) 437-1520
WS512K8-XCX
FIG. 2
AC TEST CIRCUIT
I
Current Source
D.U.T.
C = 50 pf
eff
I
OL
V
≈
1.5V
(Bipolar Supply)
Z
Current Source
OH
TRUTH TABLE
Parameter
Symbol
Condition Max Unit
Input capacitance CIN
V
IN
= 0V, f = 1.0MHz
45 pF
Output capicitance COUT
V
OUT
= 0V, f = 1.0MHz
45 pF
This parameter is guaranteed by design but not tested.
CAPACITANCE
(TA = +25°C)
AC TEST CONDITIONS
Parameter Typ Unit
Input Pulse Levels VIL = 0, VIH = 3.0 V
Input Rise and Fall 5 ns
Input and Output Reference Level 1.5 V
Output Timing Reference Level 1.5 V
NOTES:
VZ is programmable from -2V to +7V.
IOL & IOH programmable from 0 to 16mA.
Tester Impedance Z0 = 75 Ω.
VZ is typically the midpoint of VOH and VOL.
IOL & IOH are adjusted to simulate a typical resistive load circuit.
ATE tester includes jig capacitance.
ABSOLUTE MAXIMUM RATINGS
Parameter Symbol Min Max Unit
Operating Temperature TA-55 +125 °C
Storage Temperature TSTG -65 +150 °C
Signal Voltage Relative to GND VG-0.5 Vcc+0.5 V
Junction Temperature TJ150 °C
Supply Voltage VCC -0.5 7.0 V
RECOMMENDED OPERATING CONDITIONS
Parameter Symbol Min Max Unit
Supply Voltage VCC 4.5 5.5 V
Input High Voltage VIH 2.2 VCC + 0.3 V
Input Low Voltage VIL -0.5 +0.8 V
Operating Temp. (Mil.) TA-55 +125 °C
CS OE WE Mode Data I/O Power
H X X Standby High Z Standby
L L H Read Data Out Active
L X L Write Data In Active
L H H Out Disable High Z Active
DC CHARACTERISTICS
(VCC = 5.0V, GND = 0V, TA = -55°C to +125°C)
Parameter Symbol Conditions -20 -25 -35 -45 Units
Min Max Min Max Min Max Min Max
Input Leakage Current ILI VCC = 5.5, VIN = GND to VCC 10 10 10 10 µA
Output Leakage Current ILO CS = VIH, OE = VIH, VOUT = GND to VCC 10 10 10 10 µA
Operating Supply Current ICC CS = VIL, OE = VIH, f = 5MHz, Vcc = 5.5 210 210 210 210 mA
Standby Current ISB CS = VIH, OE = VIH, f = 5MHz 80 60 60 55 mA
Output Low Voltage VOL IOL = 8mA, Vcc = 4.5 0.4 0.4 0.4 0.4 V
Output High Voltage VOH IOH = -4.0mA, Vcc = 4.5 2.4 2.4 2.4 2.4 V
NOTE: DC test conditions: VIH = VCC -0.3V, VIL = 0.3V
DATA RETENTION CHARACTERISTICS
(TA = -55°C to +125°C)
Parameter Symbol Conditions -20 -25 -35 -45 Units
Min Typ Max Min Typ Max Min Typ Max Min Typ Max
Data Retention Supply Voltage VDR CS ≥ VCC -0.2V 2.0 5.5 2.0 5.5 2.0 5.5 2.0 5.5 V
Data Retention Current ICCDR1 VCC = 3V 8.0 12.8 8.0 12.8 8.0 12.8 8.0 12.8 mA