(978)927-1060 FAX (978)922-6430
www.DeltaRF.com
P.O. Box 53 416 Cabot St. Beverly, MA 01915
N Connectors
Contents
CLICK ON ANY LINE TO GO DIRECTLY TO THE INDICATED PAGE
Navigation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications and interface dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Design Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ONLINE CATALOG
Cable Connectors
Straight Cable Plugs . . . . . . . . . 8
Right Angle Cable Plugs. . . . . . 11
Tee Cable Plugs . . . . . . . . . . . . 12
Straight Cable Jacks . . . . . . . . . 12
Bulkhead Cable Jacks . . . . . . . . 14
Tee Bulkhead Cable Jacks . . . . . 15
Panel Cable Jacks . . . . . . . . . . . 17
Receptacles
Panel Jack Receptacles . . . . . . . 19
Right Angle
Panel Jack Receptacles . . . . . . . 22
Panel Plug Receptacles. . . . . . . 23
Bulkhead Jack Receptacles . . . . 24
Stripline Receptacles . . . . . . . . 24
PressMount Receptacles. . . . . . 25
Accessories
Resistive Terminations . . . . . . . 26
Dust Caps. . . . . . . . . . . . . . . . . 26
In-Series Adapters . . . . . . . . . . 27
N70 (70impedance)
Cable Connectors. . . . . . . . . . . 29
Receptacles . . . . . . . . . . . . . . . 30
In-Series Adapters . . . . . . . . . . 31
Technical Information
Cable Groups . . . . . . . . . . . . . . 32
Cable Assembly Instructions . . 33
Assembly Tooling. . . . . . . . . . . 37
Mounting Figures . . . . . . . . . . 38
Ordering and Warranty . . . . . . 39
Connect Here.
Connect Here.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 2
Online Catalog Navigation Guide
We have configured this online catalog to take advantage of Acrobat navigation shortcuts (links).
However, these links are not visible on the pages— making them visible would compromise the
page’s readability.
Clicking on any entry in the Table of Contents will take you to the indicated page.
Shown below are the “hot spots” on all of the product pages that will take you to background
information on various connector characteristics.
After you use a link to jump to another page, you can use the “back” arrow in Acrobat’s menu bar
to return to the page you jumped from.
Configure Acrobat Reader to show bookmarks for a table of contents by specific characteristic
(for example, cable plugs broken out by cable attachment method).
To find a specific part number, use Acrobat’s search feature.
In addition, the pages are formatted to fit within the margins of standard laser or inkjet printers—
no need to use the “shrink to fit” option when printing pages from Acrobat.
Click hereto go to the Table of Contents
Panel Jack—Military Clamp for Flexible Cable
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
1 1 1.75 .63 .75 33 Nickel Silver 1011-001-N330 A/20
2, 3 1 1.75 .63 .75 33 Nickel Silver 1011-004-N330 A/20
5, 6 2 1.16 .55 .50 07 Nickel Silver UG-291C/U A/17
Figure 1 Figure 2
C dia.
A
B
AB
C dia.
Assembly
Procedure/
Trim Code
Click here to jump to a guide to Delta cable groups.
Click here to jump to dimensions
for Delta mounting figures.
Click here to jump to information on alternate body plating.
Click here to jump to the cable
assembly procedure for this connector.
DELTA ELECTRONICS MANUFACTURING
BNC Cable Jacks
Click on the Delta logo on any page
to jump to the table of contents. Click on the page title to jump to specifications
and interface dimensions.
Click here to go to Delta’s website if your computer is configured for Web connection via Acrobat.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 3
Introduction and Specifications
General Description
Delta type N connectors are medium size, 50impedance connectors with 58"-24
threaded coupling.
They are best suited for use with cables in the range of .350" to .450" diameter, but are
available for other cables with diameters from .100" to over 1". M39012 QPL N connectors
and M55339 QPL N adapters are also included in this catalog. Our extensive line of type N
receptacles includes configurations for virtually any packaging requirement, and we can supply
any adapter or accessory you need to complete your system design.
As with our other connector series, Delta’s customer-driven design results in N series connectors
with practical and unique features that make your design and assembly process easier.
Some of these include:
Heli-Grip cable connectors for fast, reliable assembly to flexible cable without special tooling.
One-Step cable connectors for quick, accurate assembly to semi-rigid cable.
PressMount receptacles (page 25) mount securely in a single round hole, saving space on
your components and reducing your housing fabrication costs.
Panel receptacles with flange sizes to match the same hole pattern as standard SMA or
BNC/TNC connectors, letting you drill one hole pattern and mount BNC, N, SMA, TNC,
or 7/16 series connectors as needed.
70impedance N connectors (see page 29) for matched-impedance applications.
Our N series product line is still growing, so please call if you don’t see what you need.
For adapters between N and other series, download the document DeltaABS.pdf
from our website.
Electrical:
Nominal Impedance: 50 ohms.
Frequency Range: DC–11 GHz.
Voltage Rating: 1,000 volts RMS.
Dielectric Withstanding Voltage: 2,500 volts RMS.
Insulation Resistance: 5,000 megohms.
Materials/Finishes:
Insulators: Teflon per ASTM D1710.
Male Contacts: Brass per ASTM B16.
Female Contacts: Beryllium Copper per ASTM B196.
Contact Plating: Silver per QQ-S-365, or
Gold per MIL-G-45204.
Gaskets: Silicone rubber per ZZ-R-765, Class II, Grade 50.
Other Metal Parts: Brass per ASTM B16, plated:
Silver per QQ-S-365, or
Nickel per QQ-N-290.
All other specifications are in accordance with the
latest issues of MIL-PRF-39012, or MIL-A-55339, or other
applicable MIL specifications, and interfaces
are in accordance with MIL-STD-348.
N Specifications*
.158
.168
.827 dia.
max.
.119
.124 dia.
.630 dia.
min.
.330 dia.
max.
COMPENSATING
RING OPTIONAL
SLOTS REQUIRED;
DESIGN OPTIONAL.
.625-24 UNEF-2B
.177 min. full thread
Reference Plane
.016/.060
.210/.230
.398/.412
Plug Interface**
.047
.077
.336
.344 .316
.320
.625-24 UNEF-2A
.627 dia.
max.
.422 min.
.172/.202
.047/.077 .119/.124
Reference Plane
.356/.362 .187/.207
Jack Interface**
**Some proportions altered to illustrate detail.
*These specifications
are typical and may
not apply to all
connectors. Detailed
specifications for
individual connectors
are available on
request.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 4
Design Features
Plating options...................................................................................................................4
Panel receptacles with common flange sizes ...................................................................5
Type N receptacles with one-piece bodies .......................................................................5
Heli-Grip connectors for flexible cable .............................................................................6
Coupling nut options for N series plugs...........................................................................6
One-Step connectors for semi-rigid cable ........................................................................7
PressMount receptacles.....................................................................................................7
Design Features
About Delta’s Customer-Driven Design
At Delta, Customer-Driven Design isn’t just a catchy slogan. It means that we make RF
connectors that help you build your products efficiently, quickly, and cost-effectively. Because
we design for your needs, nobody else can offer you such a broad line of standard connectors,
along with an ever-growing list of innovative, user-friendly design variations like those detailed
on these pages.
These featured connector technologies grew out of real-world requirements, and have saved
our customers untold hours and dollars over the years. And there are thousands of other
special connector designs we’ve produced that we don’t have space to include in this catalog.
So if you don’t see the exact connector configuration you need, please call us—we may have
already made it. If not, we’ll work with you to provide the the connectors you need, with the
best price/performance balance in the business, and with quality and delivery that will enhance
your products and production schedules.
Plating Options for Economy and Performance
(Albaloy or nickel—available for all connector series except SMA)
Silver plating has long been standard on RF connectors with brass bodies, but its high cost
and low corrosion resistance make it less than ideal in most applications. Nickel plating is
less expensive and more durable than silver, and is standard on many of our connectors.
However, in some applications, nickel plating can introduce unwanted intermodulation
distortion, particularly on large size connectors. For these applications, we offer optional
Albaloy plating, a tin/zinc/copper composite with a bright white finish, the corrosion
resistance of nickel, and the low intermodulation distortion of silver plating.
Albaloy plating has the same composition as, and is fully compatible with, other
commercial platings designated Sucoplate®
,IP-23, White Bronze, and Tri-Alloy.
To order a Delta connector with plating other than the listed finish, substitute
A, N, or Qin the Delta part number as below:
For silver plating: 1111-111-A111.
For nickel plating: 1111-111-N111.
For Albaloy plating: 1111-111-Q111.
Note: M39012 and M55339 QPL connectors can only be supplied with the
specified plating. SMA connectors with stainless-steel bodies are available
with gold plating or passivated finish.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 5
Design Features
Does it make sense that you have to drill your components with different mounting hole
patterns whenever you need to ship them with a different connector series attached?
We didn’t think so, either.
That’s why we offer a wide range of connectors in different series with common flange
sizes and contact/insulator configurations. Now you can streamline your production
process and shorten your delivery cycle—just predrill your components with one
mounting hole pattern, and ship them with the connectors your customers require.
Flange Sizes and Available Interfaces
12" square flange (Delta mounting figure 05)—standard flange size for SMA
BNC N SMA TNC
1116" square flange (Delta mounting figure 09)—standard flange size for BNC, TNC
1" square flange (Delta mounting figure 33)—standard flange size for type N
.500
square
.340
(L) typ.
C
.102 dia. typ.
1.00 square
.718
(L)
typ.
C
.125 dia. typ.
BNC N SMA TNC 7/16
These connectors are available with a wide variety of post, tab, solder pot, or slotted contacts.
Common Flange Sizes Simplify Your Production
(Available on BNC, N, SMA, TNC, and 7/16 series connectors as noted in product pages)
.687
square
.500
(L) typ.
C
.125 dia. typ.
BNC N SMA TNC
N Panel Receptacles With One-Piece Bodies
(Available for most type N 4-hole flange receptacles—contact factory for exact types)
Our in-house machining capability now includes production of type
N flange receptacles with one-piece bodies, replacing the old
machined body/stamped flange method. With no unsightly solder
joints, these connectors have enhanced appearance and strength
compared with two-piece designs. The machined flanges are flatter
than stamped flanges, and our high-speed turning centers can
produce any volume required to fill your production quantity needs.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 6
Design Features
Heli-Grip®Cable Attachment—for Flexible Cable
With their reduced parts count and rapid assembly, Delta’s Heli-Grip connectors offer significant
time savings in your cable assembly operation, without the need for dedicated crimp tools.
Heli-Grip connectors have captivated contacts, and assembly is easy—simply trim the cable,
slide the trimmed cable into the cone/insulator/contact assembly (left), solder the center
conductor to the contact, and screw the body assembly (right) onto the backend assembly.
Heli-Grip connectors have cable retention strength greater than the force required to tear the
cable braid.
Cable assembled to
hardware subassembly
Backnut; cone/contact/
insulator subassembly As assembled in connector
Standard N Heli-Grip Configurations
Straight plug—page 9j Straight jack—page 13
Bulkhead jack—page 15 Panel jack—page 17
Coupling Nut Options
N plugs can be supplied with a hex coupling nut for applications requiring plugs to be
torqued to a specific value. Please call for part numbers of specific connectors with hex
coupling nuts, which can be supplied with or without safety-wire holes.
Standard coupling nut Hex coupling nut Hex coupling nut
with lockwire holes
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 7
Design Features
One-Step Cable Attachment—for Semi-Rigid Cable
(Available for N and SMA connector series as noted in product pages)
Delta One-Step connectors for semi-rigid cable have captivated contacts and insulators
preassembled in the body assembly. With no loose parts to handle, assembly is as simple as
trimming the cable (and chamfering the cable center conductor), inserting the cable into the
body assembly, and soldering the cable jacket to the connector body.
The internal design of the body assembly automatically maintains the proper gap distance
between the center contact and the cable dielectric, ensuring the best electrical performance
and eliminating the shimming operation required by connectors with non-captive contacts.
Standard N One-Step Configurations
Straight plug—page 10 Bulkhead jack—page 16 Panel jack—page 18
Delta PressMount Receptacles
Delta PressMount receptacles eliminate the need for complicated mounting hole patterns and
mounting hardware. They are simply pressed into a single through hole, and can be used in
component housings as small as the outer diameter of the connector. An integral shoulder
provides a positive depth stop during mounting.
Besides the standard types shown below, PressMount receptacles are available with a wide
variety of contact and insulator configurations—please call if you don’t see what you need.
Component housing
Internal
Circuitry
Knurl
Shoulder
Connector design
As mounted
on component
Standard N PressMount Receptacles
N jack
(Solder pot, tab, or
post contact—page 25)
N plug
(Solder pot, tab, or
post contact—page 25)
Straight Plug—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
1 1 1.50 .75 Nickel Silver UG-18E/U A/01
1 1 1.50 .75 Nickel Silver (C)1101-001-N001 A/01
2, 3 1 1.80 .68 Nickel Silver UG-21B/U C/01
2, 3 1 1.50 .75 Nickel Gold UG-21D/U A/01
2, 3 1 1.50 .75 Nickel Gold UG-21E/U A/01
2, 3 1 1.50 .75 Nickel Gold UG-21G/U A/01
2, 3 1 1.50 .75 Nickel Silver (C)UG-1185/U A/01
2, 3 1 1.50 .75 Nickel Gold (C)UG-1185A/U A/01
2, 3 1 1.50 .75 Silver Gold (C)M39012/01-0005* A/01
5, 6 2 1.41 .50 Nickel Silver UG-536B/U A/02
5, 6 2 1.41 .50 Nickel Gold UG-536C/U A/02
5, 6 2 1.41 .50 Nickel Gold (C)1101-015-N001 A/02
7 2 1.38 .50 Nickel Silver UG-603A/U A/02
7 2 1.38 .50 Nickel Silver (C)1101-021-N001 A/02
8 2 1.41 .50 Nickel Silver (C)1101-043-N001 A/02
9 2 1.38 .50 Nickel Silver 1101-036-N000 A/02
9 2 1.38 .50 Nickel Silver (C)1101-036-N001 A/02
15 3 2.42 .75 Nickel Silver UG-941B/U D/01
15 3 2.42 .75 Silver Gold (C)M39012/01-0125* D/03
16 1 1.80 .88 Nickel Silver UG-204A/U C/02
16 1 1.80 .88 Silver Gold (C)M39012/01-0015* A/01
20 3 3.09 1.31 Nickel Silver UG-557A/U D/02
25 2 1.38 .50 Nickel Silver 1101-132-N000 A/03
Figure 1 Figure 2
A
B dia.
A
B dia.
Figure 3
(Includes armor clamp)
A
B dia.
* Lockwire holes in coupling nut.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 8
N Cable Plugs
Optional Type N Coupling Nut Examples
These designs allow the connectors to be tightened with a wrench for precise torquing of mated parts, and can be supplied
on any Delta type N plug. Please call for details of these options or any other special requirements you may have.
.812 hex
.812 hex
.033 dia.
lockwire holes (3)
13/16" hex coupling nut with lockwire holes
13/16" hex coupling nut
(C) in contact plating column indicates captive contact.
Straight Plug—Crimp Type for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2 1 1.51 .63 Nickel Silver 1103-002-N000 B/01
2 1 1.55 .63 Nickel Gold (C)1103-002-N001-9 B/03
2 1 1.55 .60 Silver Gold (C)M39012/01B0007* B/03
2 1 1.55 .60 Silver Gold (C)M39012/01-0502* B/03
2B 1 1.55 .63 Nickel Silver 1103-070-N000 B/01
3A, 4 1 1.55 .63 Nickel Gold (C)1103-004-N001-1 B/03
3A, 4 1 1.51 .63 Nickel Silver 1103-005-N000 B/01
3A, 3C, 4 1 1.55 .60 Silver Gold (C)M39012/01B0008* B/03
3A, 3C, 4 1 1.55 .60 Silver Gold (C)M39012/01-0501* B/03
4 1 1.50 .63 Nickel Silver 1103-079-N000 B/01
5 2 1.43 .50 Nickel Silver 1103-017-N000 B/04
5 1 1.48 .50 Nickel Gold (C)1103-017-N001 B/05
6 2 1.43 .50 Nickel Silver 1103-013-N000 B/04
6 1 1.45 .50 Nickel Gold (C)1103-018-N001 B/03
6 1 1.45 .50 Silver Gold (C)M39012/01-0503* B/03
7 2 1.43 .50 Nickel Silver 1103-020-N000 B/06
7 1 1.38 .50 Nickel Gold (C)1103-020-N001 B/03
Figure 1
A
B
(crimp sleeve)
Figure 2
A
B
(crimp sleeve)
* Lockwire holes in coupling nut.
Straight Plug—Heli-Grip®for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2, 3 1 1.50 .75 Nickel Gold (C)1101-004-N005 E/01
§5, 6§2 1.41 .50 Nickel Gold (C)1101-015-N005 E/02
RG-223 2 1.41 .50 Nickel Gold (C)1101-015-N005-1 E/02
7 2 1.38 .50 Nickel Gold (C)1101-021-N005 E/02
24 1 1.50 .75 Nickel Gold (C)1101-052-N005 E/01
26 1 1.50 .75 Nickel Gold (C)1101-108-N005 E/01
Heli-Grip®Cable Attachment
These connectors have captivated contacts and allow
rapid, easy assembly—simply trim the cable, slide into
the cone/insulator/contact assembly (left), solder the
center conductor to the contact, and screw body
assembly (right) onto cable assembly.
§Except RG-223/U.
Figure 1 Figure 2
A
B dia.
A
B dia.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 9
N Cable Plugs
(C) in contact plating column indicates captive contact.
Straight Plug—For Semi-Rigid Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
12 1 1.50 .50 Nickel Silver 1101-050-N000 F/03
12 2 .96 .254 Mixed(1)Silver 1101-050-N003 ***
12 4 1.44 .254 Silver Gold (C)1101-050-A003-7 I/01
13 1 1.41 .50 Nickel Silver 1101-031-N003 F/01
13 2 .96 .143 Mixed(1)Gold 1101-031-N003-1 ***
13 2 .96 .143 Mixed(2)Gold 1101-031-K00M ***
13 3 .96 .143 Silver Gold (C)1101-031-A003-8 I/01
13 4 .96 .143 Silver Gold (C)1101-031-A003-12 I/01
14 1 1.41 .50 Nickel Silver 1101-025-N003 F/02
Figure 1
(Solder-clamp; gold-plated
ferrule, nickel-plated body)
A
B dia.
Figure 2
(Direct solder; gold-plated body, nickel(1)
or passivated(2)coupling nut)
A
B (I.D.)
Figure 4
(One-Step cable attachment, hex coupling nut)
A
B (I.D.)
.812 hex
Figure 3
(One-Step cable attachment, standard coupling nut)
A
B (I.D.)
Delta One-Step Cable Attachment for Semi-Rigid Cable
Solder
Cable
Delta “One-Step” connectors feature captivated
contacts and insulators to allow rapid, easy assembly
to semi-rigid cable—simply trim the cable jacket and
dielectric flush, chamfer the center conductor, insert
into the connector, and solder the jacket to the
connector body.
(1)Brass body and coupling nut.
(2)Stainless steel body and coupling nut.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 10
N Cable Plugs
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Right Angle Plug—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B C Body Contact Trim Code
2, 3 1 1.47 1.88 .75 Nickel Silver (C)UG-594B/U A/01
2, 3 3 1.36 1.66 .75 Silver Gold (C)M39012/05-0101 A/07
2, 3 3 1.39 1.66 .75 Nickel Gold 1105-004-N000 A/04
5 3 1.39 2.00 .75 Nickel Gold (C)1104-032-N001 A/08
5, 6 2 1.55 1.28 .50 Nickel Silver (C)1105-015-N000 A/11
5, 6 3 1.35 1.55 .56 Nickel Silver (C)1105-015-N001 A/09
7 2 1.55 1.28 .50 Nickel Silver (C)1105-021-N000 A/11
9 2 1.55 1.28 .50 Nickel Silver (C)1105-036-N001 A/11
19 3 1.36 1.66 .75 Nickel Silver (C)1104-027-N001 A/07
Figure 1
(Mitered body) Figure 2
(Cube body with access cap)
A
B
C dia.
A
B
C dia.
Figure 3
(Cube body)
A
B
C dia.
Right Angle Plug—Crimp Type for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B C Body Contact Trim Code
2 1 1.39 1.77 .75 Nickel Silver 1107-002-N000 B/07
2 2 1.39 1.25 . Nickel Silver (C)1107-002-N000-1 B/09
3 1 1.39 1.77 .75 Nickel Silver 1107-005-N000 B/07
2 3 1.41 2.30 .687 Nickel Gold (C)1107-002-N001-2 B/30
3 3 1.41 2.30 .687 Nickel Gold (C)1107-004-N001-2 B/30
6 3 1.41 2.25 .687 Nickel Gold (C)1107-034-N001-1 B/08
Figure 1
(Cube body) Figure 2
(Cube body with access cap)
A
B
C dia.
A
B
Figure 3
(Mitered body)
A
B
C dia.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 11
N Cable Plugs
(C) in contact plating column indicates captive contact.
Tee Plug—For Flexible and Semi-Rigid Cable
Figure 1
(Crimp type for
flexible cable)
Figure 2
(Direct solder for
semi-rigid cable)
A
B
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2 1 1.39 2.00 Silver Silver (C)1185-002-A000 B/16
3 1 1.39 2.00 Silver Silver (C)1185-004-A000-2 B/16
6 1 1.39 1.82 Silver Silver (C)1185-013-A001 B/17
7 1 1.39 1.82 Silver Silver (C)1185-019-A000 B/17
9 1 1.39 1.82 Silver Silver (C)1185-036-A000 B/17
13 2 1.39 .90 Silver Silver (C)1185-031-A000 ***
A
B
Straight Jack—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
1 1 1.56 .75 Nickel Silver UG-20E/U A/01
1 1 1.67 .75 Silver Gold (C)M39012/02-0101 A/01
2, 3 1 1.56 .75 Nickel Silver UG-23D/U A/01
2, 3 1 1.56 .75 Nickel Gold UG-23F/U A/01
2, 3 1 1.56 .75 Nickel Silver (C)UG-1186/U A/01
2, 3 1 1.56 .75 Nickel Silver (C)UG-1186A/U A/01
2, 3 1 1.67 .75 Silver Gold (C)M39012/02-0003 A/01
5, 6 2 1.41 .50 Nickel Silver 1108-015-N000 A/05
5, 6 2 1.47 .50 Nickel Silver (C)1108-015-N001 A/02
7 2 1.41 .50 Nickel Silver UG-602A/U A/02
7 2 1.27 .50 Nickel Silver 1108-000-N000-3*—
7 2 1.47 .50 Nickel Silver (C)1108-021-N001 A/02
15 3 2.25 .75 Nickel Silver UG-940B/U D/03
19 1 1.56 .75 Nickel Gold (C)1108-027-N001 A/12
22 1 1.87 .69 Nickel Gold 1108-123-N000 C/03
Figure 1 Figure 2
A
B dia.
A
B dia.
Figure 3
(Includes armor clamp)
A
B dia.
*UG-602A/U less clamping hardware.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 12
N Cable Plugs/Jacks
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Straight Jack—Crimp Type for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2 1 1.64 .60 Silver Gold (C)M39012/02B0008 B/10
2 1 1.64 .60 Silver Gold (C)M39012/02-0502 B/03
2 1 1.47 .50 Nickel Gold 1110-002-N000 B/10
2 1 1.60 .63 Nickel Gold (C)1110-002-N001 B/11
3 1 1.64 .60 Silver Gold (C)M39012/02B0009 B/10
3 1 1.64 .60 Silver Gold (C)M39012/02-0501 B/03
3 1 1.47 .50 Nickel Gold 1110-005-N000 B/10
3 1 1.60 .63 Nickel Gold (C)1110-005-N001 B/10
6 1 1.56 .50 Nickel Gold 1110-013-N000-1 B/12
6 1 1.54 .50 Silver Gold (C)M39012/02-0503 B/03
Figure 1
A
B
(crimp sleeve)
Straight Jack—Heli-Grip®for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2, 3 1 1.63 .75 Nickel Gold (C)1108-004-N005-2 E/01
§5, 6§2 1.41 .50 Nickel Gold (C)1108-018-N005-2 E/02
RG-223 2 1.41 .50 Nickel Gold (C)1108-015-N005 E/02
7 2 1.41 .50 Nickel Gold (C)1108-019-N005-2 E/02
8 2 1.41 .50 Nickel Gold (C)1108-029-N005-1 E/02
9 2 1.41 .50 Nickel Gold (C)1108-037-N005-2 E/02
§Except RG-223/U.
Figure 1 Figure 2
A
B dia.
A
B dia.
Straight Jack—For Semi-Rigid Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
12 1 1.07 .254 Silver Gold 1108-050-A003-3 ***
13 2 1.00 .143 Silver Gold 1108-031-A003 ***
Figure 1
A
B (I.D.)
Figure 2
A
B (I.D.)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 13
N Cable Jacks
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Bulkhead Jack—Military Clamp for Flexible Cable
Cable Fig. Dimensions Mounting Max. Plating Delta P/N
Group ABCD Figure Panel Body Contact
1 1 1.75 .92 .75 .900 72 .25 Silver Gold (C)M39012/03-0101 A/01
2, 3 1 1.75 .92 .75 .875 72 .25 Nickel Silver UG-160D/U A/01
2, 3 1 1.84 .92 .75 .812 72 .25 Nickel Silver (C)1116-003-N721 ***
2, 3 1 1.75 .92 .75 .875 72 .25 Nickel Gold 1116-004-N720-1 A/01
5, 6 2 1.67 .92 .50 .812 72 .25 Nickel Silver UG-556B/U A/06
5, 6 2 1.67 .92 .50 .875 72 .25 Nickel Gold (C)1116-015-N721 A/02
7 2 1.47 .92 .50 .875 72 .25 Nickel Silver 1116-021-N720 A/14
7 2 1.47 .92 .50 .875 72 .25 Nickel Gold (C)1116-021-N721 A/14
9 2 1.48 .92 .50 .875 72 .25 Nickel Silver (C)1116-036-N721 A/10
10 2 1.48 .92 .50 .875 72 .25 Nickel Silver (C)1116-100-N721 A/10
11 2 1.48 .92 .50 .875 72 .25 Nickel Silver (C)1116-038-N721 A/10
16 1 1.90 .92 .88 .875 72 .25 Silver Gold (C)M39012/03-0102 A/01
Figure 1
(Rear mount) Figure 2
(Rear mount)
D dia.
AB
C dia.
AB
C dia.
D dia.
Assembly
Procedure/
Trim Code
Bulkhead Jack—Crimp Type for Flexible Cable
Figure 1
(Rear mount)
ABD dia.
C
(crimp sleeve)
Cable Fig. Dimensions Mounting Max. Plating Delta P/N
Group ABCD Figure Panel Body Contact
2 1 1.84 .92 .60 .875 72 .25 Silver Gold (C)M39012/03B0004 B/03
2 1 1.84 .92 .60 .875 72 .25 Silver Gold (C)M39012/03-0502 B/03
3 1 1.84 .92 .60 .875 72 .25 Silver Gold (C)M39012/03B0005 B/03
3 1 1.84 .92 .60 .875 72 .25 Silver Gold (C)M39012/03-0501 B/03
6 1 1.74 .95 .50 .875 72 .25 Nickel Gold (C)1119-013-N721 B/13
6 1 1.74 .92 .50 .875 72 .25 Silver Gold (C)M39012/03-0503 B/03
7 1 1.59 .92 .50 .812 72 .25 Nickel Silver 1119-020-N720 B/14
9 1 1.45 .88 .44 .812 72 .25 Nickel Silver (C)1119-036-N721 B/15
10 1 1.45 .88 .44 .812 72 .25 Nickel Gold (C)1119-100-N721 B/15
Assembly
Procedure/
Trim Code
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 14
N Cable Jacks
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Bulkhead Jack—Heli-Grip®for Flexible Cable
Cable Fig. Dimensions Mounting Max. Plating Delta P/N
Group ABC Figure Panel Body Contact
2, 3 1 1.84 .92 .75 72 .25 Nickel Gold (C)1116-004-N725 E/01
§5, 6§2 1.69 .92 .50 72 .25 Nickel Gold (C)1116-015-N725 E/03
RG-223 2 1.69 .92 .50 72 .25 Nickel Gold (C)1116-015-N725-1 E/03
7 2 1.69 .92 .50 72 .25 Nickel Gold (C)1116-021-N725 E/03
10 2 1.69 .92 .50 72 .25 Nickel Gold (C)1116-100-N725 E/03
Figure 1
.812 dia.
AB
C dia.
Assembly
Procedure/
Trim Code
§Except RG-223/U.
Heli-Grip®Cable Attachment
Figure 2
AB
C dia.
.812 dia.
These connectors have captivated contacts and allow
rapid, easy assembly—simply trim the cable, slide into
the cone/insulator/contact assembly (left), solder the
center conductor to the contact, and screw body assembly
(right) onto cable assembly.
Tee Bulkhead Jack—For Flexible and Semi-Rigid Cable
Cable Fig. Dimensions Mounting Max. Plating Delta P/N
Group ABC Figure Panel Body Contact
2 1 1.40 2.00 .75 55 .10 Silver Silver (C)1185-002-A551 B/16
3 1 1.40 2.00 .75 55 .10 Silver Silver (C)1185-004-A551 B/16
6 1 1.38 1.89 .75 55 .10 Silver Silver (C)1185-013-A551 B/17
7 1 1.38 1.89 .75 55 .10 Silver Silver (C)1185-019-A551 B/17
9 1 1.38 1.89 .75 55 .10 Silver Silver (C)1185-036-A551 B/17
13 2 1.38 .90 .75 55 .10 Silver Silver (C)1185-031-A551 ***
Assembly
Procedure/
Trim Code
Figure 1
(Crimp type for
flexible cable)
Figure 2
(Direct solder for
semi-rigid cable)
A
B
.675
C dia.
A
B
.675
C dia.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 15
N Cable Jacks
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Bulkhead Jack—For Semi-Rigid Cable
Figure 2
(Solder-clamp; gold-plated ferrule,
nickel-plated body)
AB
C dia.
.812 dia.
Figure 4
(One-Step cable attachment)
C (I.D.)
.875 dia.
AB
Figure 1
(Collet clamp [solderless] cable attachment, captive contact in body)
.812 dia.
AB
C across flats
Backnut Collet Ferrule
O-ring
Delta One-Step Cable Attachment
for Semi-Rigid Cable
Solder
Cable
Delta “One-Step” connectors feature captivated
contacts and insulators to allow rapid, easy
assembly to semi-rigid cable—simply trim the
cable jacket and dielectric flush, chamfer the
center conductor, insert into the connector, and
solder the jacket to the connector body.
Figure 3
(Direct solder)
.812 dia.
AB
C (I.D.)
Cable Fig. Dimensions Mounting Max. Plating Delta P/N
Group ABC Figure Panel Body Contact
12 1 1.55 .889 .50 72 .25 Nickel Gold (C)1116-163-N721 ***
13 2 1.67 .922 .50 72 .25 Nickel Gold 1116-031-N720 F/04
13 3 1.33 .884 .145 72 .25 Nickel Gold 1116-031-N723-1 ***
13 4 1.38 .922 .143 72 .25 Silver Gold (C)1116-031-A723-3 I/01
14 2 1.67 .922 .50 72 .25 Nickel Gold 1116-025-N723 F/04
14 3 1.33 .884 .090 72 .25 Nickel Gold 1116-025-N723-1 ***
14 4 1.38 .922 .088 72 .25 Silver Gold (C)1116-025-A723-2 I/01
Assembly
Procedure/
Trim Code
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 16
N Cable Jacks
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Panel Jack—For Flexible Cable
Military Clamp for Flexible Cable
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
1 1 1.67 .66 .75 33 Silver Gold (C)M39012/02-0104 A/01
2, 3 1 1.58 .66 .75 33 Nickel Silver UG-22D/U A/01
2, 3 1 1.58 .66 .75 33 Nickel Gold UG-22F/U A/01
2, 3 1 1.58 .66 .75 33 Nickel Silver (C)UG-1187/U A/01
2, 3 1 1.58 .66 .75 33 Nickel Silver (C)UG-1187A/U A/01
2, 3 1 1.67 .66 .75 33 Silver Gold (C)M39012/02-0006 A/01
5, 6 2 1.41 .66 .50 33 Nickel Silver UG-1095B/U A/13
5, 6 2 1.41 .66 .50 33 Nickel Gold UG-1095C/U A/13
5, 6 2 1.41 .66 .50 27 Nickel Silver 1111-015-N270 A/13
5, 6 2 1.48 .66 .50 27 Nickel Gold (C)1111-015-N271 A/02
5, 6 2 1.41 .66 .50 33 Nickel Silver (C)1111-015-N331 A/02
7 2 1.41 .66 .50 33 Nickel Silver UG-593A/U A/14
9 2 1.44 .66 .50 33 Nickel Silver 1111-036-N330 A/16
9 2 1.48 .66 .50 33 Nickel Silver (C)1111-036-N331 A/15
19 1 1.56 .66 .75 33 Nickel Gold (C)1111-027-N331 A/12
22 1 1.87 .66 .69 30 Nickel Gold 1111-123-N300 C/03
Assembly
Procedure/
Trim Code
Figure 1
A
B
C dia.
Heli-Grip®Cable Attachment (where noted)
Figure 2
AB
C dia.
These connectors have captivated contacts and allow
rapid, easy assembly—simply trim the cable, slide into
the cone/insulator/contact assembly (left), solder the
center conductor to the contact, and screw body assembly
(right) onto cable assembly.
§Except RG-223/U.
Heli-Grip for Flexible Cable
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
2, 3 1 1.58 .66 .75 33 Nickel Gold (C)1111-004-N335 E/01
§5, 6§2 1.41 .66 .50 33 Nickel Gold (C)1111-015-N335 E/03
RG-223 2 1.41 .92 .50 33 Nickel Gold (C)1111-015-N335-1 E/03
7 2 1.41 .66 .50 33 Nickel Gold (C)1111-021-N335 E/03
9 2 1.41 .66 .50 33 Nickel Gold (C)1111-037-N335-1 E/03
10 2 1.41 .66 .50 33 Nickel Gold (C)1111-100-N335-1 E/03
Assembly
Procedure/
Trim Code
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 17
N Cable Jacks
(C) in contact plating column indicates captive contact.
Panel Jack—Crimp Type for Flexible Cable
Figure 2
(Contact and insulator captive in backnut)
Figure 1
(Standard crimp type)
AB
C
Backnut/crimp tail
Crimp sleeve Captive
contact
Captive
insulator
A
BC
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
2 1 1.64 .66 .60 33 Silver Gold (C)M39012/02-0512 B/03
3 1 1.64 .66 .60 33 Silver Gold (C) M39012/02-0511 B/03
5 2 1.19 .595 .50 33 Nickel Silver (C)1155-017-N331 ***
6 2 1.19 .595 .50 33 Nickel Silver (C)1155-013-N331 ***
6 1 1.54 .66 .50 33 Silver Gold (C) M39012/02-0513 B/03
9 2 1.16 .595 .38 33 Nickel Silver (C)1155-037-N331 ***
Assembly
Procedure/
Trim Code
Panel Jack—For Semi-Rigid Cable
Figure 1
(Solder-clamp; gold-plated ferrule,
nickel-plated body)
AB
C dia.
Figure 2
(One-Step cable attachment—see page 74 for details)
Figure 3
(One-Step cable attachment—see page 74 for details)
C (I.D.)
AB
AB
C (I.D.)
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
13 1 1.41 .66 .50 33 Nickel Gold 1111-031-N333-1 F/05
13 2 1.11 .66 .143 09 Silver Gold (C)1111-031-A091-1 I/01
13 3 1.07 .64 .143 33 Silver Gold (C)1111-031-A333-4 I/01
14 1 1.41 .66 .50 33 Nickel Gold 1111-025-N333 F/05
14 2 1.11 .66 .088 09 Silver Gold (C)1111-025-A091-1 I/01
14 3 1.07 .64 .088 33 Silver Gold (C)1111-025-A333-2 I/01
Assembly
Procedure/
Trim Code
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 18
N Cable Jacks
(C) in contact plating column indicates captive contact.
Panel Jack Receptacle—Solder Pot Contact
Figure Dimensions Mounting Plating Delta P/N
ABCD Figure Body Contact
1 1.13 .66 .100 .080 33 Nickel Silver (C)UG-58A/U
1 1.13 .66 .100 .080 33 Silver Gold (C)M39012/04-0002
1 1.13 .66 .100 .080 18 Nickel Silver (C)1113-000-N181
1 1.13 .66 .100 .080 32A Nickel Silver (C)1113-000-N321-2
1 1.13 .66 .100 .080 32 Nickel Gold (C)1113-000-N321-3
1 1.13 .66 .100 .080 33 Silver Gold (C)1113-000-A331-11
1 1.13 .66 .100 .080 33 Nickel Gold (C)1113-000-N331-11
1 1.13 .66 .100 .080 95 Nickel Silver (C)1113-000-N951
2 .735 .075 .125 .25 09 Nickel Silver (C)1113-000-N091-2
3 1.13 .66 .100 .080 33 Nickel Gold (C)1113-000-N331-9
Figure 1 Figure 2
(11/16" square flange, interchangeable with
BNC and TNC standard flange size)
AB
D
C (I.D.)
A
B
C
D
.162 dia.
.050 dia.
.032
(I.D.)
Figure 3
AB
D
C (I.D.)
Panel Jack Receptacle—Solder Pot Contact
Round flange (for solder or setscrew mounting)
Figure Dimensions Plating Delta P/N
A B C D E Body Contact
1 1.25 .66 .100 .175 1.50 Nickel Silver (C)1113-000-N911-2
1 1.25 .66 .100 .125 1.25 Nickel Gold (C)1113-000-N911-5
2 1.13 .66 .100 .11 .575 Nickel Silver (C)1120-000-N831
Figure 1
AB
D
C (I.D.)
E dia.
Figure 2
AB
D
C (I.D.)
E dia.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 19
N Receptacles
(C) in contact plating column indicates captive contact.
Panel Jack Receptacle—Slotted Contact
Figure Dimensions Mounting Plating Delta P/N
ABC D Figure Body Contact
1 .735 .050 .086 .012/.017 09 Nickel Gold (C)*1143-000-N091-2
1 .735 .050 .086 .036 09 Nickel Gold (C)*1143-000-N091-3
1 .735 .050 .086 .007/.012 09 Nickel Gold (C)*1143-000-N091-4
1 .735 .050 .050 .012/.017 09 Nickel Gold (C)*1143-000-N091-9
2 .736 .080 .050 .012/.017 33 Nickel Gold (C)*1143-000-N330-10
2 .736 .080 .050 .026/.030 33 Nickel Gold (C)*1143-000-N331-17
2 .736 .080 .050 .020/.025 33 Nickel Gold (C)1143-000-N331-23
2 .735 .080 .050 .026/.030 33 Nickel Gold (C)1143-000-N331-54
2 .736 .080 .050 .012/.017 33 Nickel Gold (C)1143-000-N331-55
Figure 1
(11/16" square flange, interchangeable
with BNC and TNC standard flange size)
Figure 2
A
.075
B
C dia.
D
slot
width
C
D
slot
width
A
B
.120
dia.
*Epoxy-captivated contact.
Panel Jack Receptacle—Tab Contact
Figure Dimensions Mounting Plating Delta P/N
ABC D Figure Body Contact
1 .736 .080 .195 .35 33 Nickel Gold (C)*1143-000-N330-12
2 .736 .080 .100 .005/.008 33 Silver Gold (C)* 1158-000-A331-12
3 .735 .075 .050 .004/.006 09 Silver Gold (C)* 1158-000-A091-23
Figure 1
Figure 3
(11/16" square flange, interchangeable
with BNC and TNC standard flange size)
A
B
C
D
Tab
.005/.010
thick x
.120 wide
.384 dia.
A
B
C
Tab
D thick x
.050 wide
*Epoxy-captivated contact.
Figure 2
A
B
C
Tab
D thick x
.120 wide
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 20
N Receptacles
(C) in contact plating column indicates captive contact.
Panel Jack Receptacle—Post Contact
Figure Dimensions Mounting Plating Delta P/N
ABCD Figure Body Contact
1 .736 .080 .66 .56 33 Nickel Gold (C)1113-000-N331-28
2 .735 .075 .125 .25 09 Nickel Silver (C)1143-000-N091-18
2 .735 .075 .125 .25 09 Nickel Gold (C)1143-000-N091-30
2 .735 .075 .590 .705 09 Nickel Gold (C)*1143-000-N091-69
3 .736 .080 .590 .705 33 Nickel Gold 1143-000-N330-18
3 .736 .080 .590 .705 33 Nickel Gold (C)*1158-000-N331-15
4 .814 .080 .590 .705 05 Nickel Gold (C)1143-000-N051-2
5 .735 .075 .200 .450 09 Nickel Gold (C)1143-000-N091-59
5 .735 .075 .750 .875 09 Nickel Gold (C)1143-000-N091-73
5 .735 .075 .375 .425 09 Nickel Gold (C)* 1143-000-N091-75
Figure 1 Figure 2
(11/16" square flange, interchangeable with
BNC and TNC standard flange size)
A
B
C
D
.120 dia.
A
B
C
D
.162 dia.
.050 dia.
Figure 3
A
B
C
D
.120 dia.
.384 dia.
Figure 4
(1/2" square flange, interchangeable
with SMA standard flange size)
A
B
C
D
.162 dia.
.050 dia.
Figure 5
(O-ring seal on flange, 11/16" square flange,
interchangeable with BNC and TNC standard flange size)
A
B
C
D
.162 dia.
O-ring
.050 dia.
*Epoxy-captivated contact.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 21
N Receptacles
(C) in contact plating column indicates captive contact.
Right Angle Panel Jack Receptacle
Figure Dimensions Mounting Plating Delta P/N
ABC D Figure Body Contact
1 1.41 1.16 .30 .101 33 Nickel Silver (C)UG-997A/U
1 1.41 1.16 .30 .101 33 Nickel Gold (C)1115-000-N330-5
2 1.41 1.16 .75 .120 33 Nickel Silver (C)1115-000-N330-9
3 1.41 .830 .56 .120 33 Nickel Gold (C)1115-000-N330-12
4 1.41 1.17 .050 .020/.025 33 Nickel Silver (C)1115-000-N330-11
Figure 1 Figure 2
B
A
C
D (I.D.)
B
A
C
D dia.
Figure 3
B
A
C
D dia.
Figure 4
B
A
C
D
slot
width
.120
dia.
Dummy Receptacle
A
B
Dimensions Mounting Figure Plating Delta P/N
A B Body Contact
.740 .080 33 Nickel 1163-000-N330
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 22
N Receptacles
(C) in contact plating column indicates captive contact.
Panel Plug Receptacles
Figure 1
(Solder pot
contact)
AD
B
C (I.D.)
C
D
slot
width
A
B
.120
dia.
A
B
C
.050 dia.
D
slot
width
A
B
C
D
.162 dia.
.050 dia.
A
B
C
D dia.
A
B
C
Tab
D thick x
.065 wide
Figure 2
(Slotted
contact)
Figure 3
(Slotted
contact)
Figure 4
(Tab
contact)
Figure 6
(Post
contact)
Figure 5
(Post
contact)
A
B
C
D
.120 dia.
.384 dia.
Figure 7
(Post contact)
Figure Dimensions Mounting Plating Delta P/N
ABC D Figure Body Contact
1 1.10 .080 .101 .72 33 Nickel Silver (C)1123-000-N330
1 1.10 .080 .101 .72 33 Nickel Gold (C)1123-000-N330-4
2 .78 .080 .050 .012/.017 33 Nickel Gold (C)1159-000-N330-1
2 .81 .080 .050 .012/.017 33 Nickel Gold (C)1159-000-N330-13
2 .81 .080 .050 .026/.030 33 Nickel Gold (C)*1159-000-N331-26
3 1.17 .075 .050 .020 09 Nickel Gold (C)*1159-000-N091-4
4 .81 .080 .100 .005/.008 33 Nickel Gold (C)*1159-000-N331-9
5 .81 .080 .36 .120 33 Nickel Gold (C)1123-000-N330-2
6 1.17 .075 .125 .250 09 Nickel Gold (C)1159-000-N091-10
7 .81 .080 .590 1.10 33 Nickel Gold (C)*1159-000-N331-6
7 .81 .080 .330 .488 33 Nickel Gold 1159-000-N330-11
7 .81 .080 .330 .488 33 Nickel Gold (C)*1159-000-N331
*Epoxy-captivated contact.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 23
N Receptacles
(C) in contact plating column indicates captive contact.
Bulkhead Jack Receptacles
Figure Dimensions Max. Mounting Plating Delta P/N
ABC
Panel Figure Body Contact
1 1.62 .707 .099 .100 72 Nickel Silver (C)UG-680/U
1 1.62 .707 .099 .100 72 Nickel Silver (C)UG-680A/U
1 1.62 .707 .099 .100 72 Silver Gold (C)M39012/04-0001
2 1.53 .919 .099 .250 72 Nickel Silver (C)1121-000-N728-5
3 1.25 .606 .099 .100 59 Nickel Silver (C)1120-000-N590
3 1.25 .606 .099 .100 59 Nickel Gold (C)1120-000-N590-4
4 1.25 .562 .099 .100 ** Nickel Silver (C)1120-000-N591
Figure 1
(Front mount, hermetically sealed, with mounting gasket)
Figure 4
(Front mount, no gasket, screw-in type
for 9/16–24 tapped hole)
Figure 3
(Front mount, no gasket)
Figure 2
(Rear mount, hermetically sealed, with mounting gasket)
.812 dia. AB
C (I.D.)
C (I.D.)
.812 dia.
AB
AB
C (I.D.)
AB
C (I.D.)
Stripline Receptacles
Figure Dimensions Plating Delta P/N
A B C D E F G H Body Contact
1 #2-56 .250 7 .560 #0-80 .125 .734 .422 Nickel Silver 1156-000-N000
1 .078 .313 7 .500 .063 .156 .734 .656 Nickel Silver 1156-000-N000-2
1 #2-56 .250 7 .560 #2-56 .125 .734 .422 Nickel Silver 1156-000-N000-3
2 #2-56 .125 10 .734 .125 .010 .816 .125 Nickel Silver 1157-000-N000-3
Figure 1 Figure 2
Socket contact E dia. x F deep
C holes, A dia. x B deep
D dia. b.c.
GH
.750
dia.
.120 dia.
.140 dia.
.875 dia.
D
dia. b.c.
G
H
E
C holes, A dia. x B deep
F
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 24
N Receptacles
(C) in contact plating column indicates captive contact.
PressMount Receptacles—Jack Type
Figure Dimensions Min. Mounting Plating Delta P/N
AB
Panel Hole Body Contact
1 .110 .050 .200 .450 ±.001 dia. Nickel Gold (C)1120-000-N911-2
2 .100 .005/.008 .200 .450 ±.001 dia. Nickel Gold (C)1120-000-N911-3
3 .285 .100 .200 .450 ±.001 dia. Nickel Gold (C)1120-000-N911-4
Figure 1
(Post contact)
.587
.25
.625 dia. A
B dia.
.454
dia. over knurl
Figure 2
(Tab contact)
.587
.625 dia. A
Tab
B thick x
.120 wide .25
.454
dia. over knurl
Figure 3
(Solder pot contact)
.587
.25
.625 dia. A
.120 dia.
C (I.D.)
.454
dia. over knurl
PressMount Receptacles—Plug Type
Figure Dimensions Min. Mounting Plating Delta P/N
AB
Panel Hole Body Contact
1 .110 .050 .200 .450 ±.001 dia. Nickel Gold (C)1124-000-N911-1
2 .100 .005/.008 .200 .450 ±.001 dia. Nickel Gold (C)1124-000-N911-2
3 .285 .100 .200 .450 ±.001 dia. Nickel Gold (C)1124-000-N911
Figure 1
(Post contact)
.25
A
B dia.
.95
.454
dia. over knurl
Figure 2
(Tab contact)
A
.25
.95
.454
dia. over knurl
Tab
B thick x
.120 wide
Figure 3
(Solder pot contact)
A
.120 dia.
C (I.D.)
.25
.95
.454
dia. over knurl
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 25
N Receptacles
Delta PressMount Receptacles
Component housing
Internal
Circuitry
These connectors eliminate the need for complicated mounting hole patterns and mounting hard-
ware. They are simply pressed into a single through hole, and the precisely-engineered knurled
mounting section provides retention strength far greater than normal mating and unmating
forces.
An integral shoulder provides a positive stop when mounting.
PressMounts can be used in packages as small as the outer diameter of the connector body.
(C) in contact plating column indicates captive contact.
Resistive Termination (Plug Type)
Resistor Dimensions Features Plating Delta P/N
A B C Body Contact
50±1%, 1 Watt 1.78 .. No chain Nickel Silver (C)1151-000-N000-3
50±1%, 1 Watt 1.87 5.00 .144 Nickel Gold (C)1151-000-N000-10
51±5%, 1/2Watt 1.61 3.50 .144 Nickel Silver (C)1131-000-N000
51±5%, 1/2Watt 1.67 .. No chain Nickel Silver (C)1131-000-N00A
51±5%, 1 Watt 1.87 3.75 .144 Nickel Silver (C)1151-000-N000
75±1%, 1 Watt 1.87 5.00 .144 Nickel Gold (C)1151-000-N000-11
A
B
C (I.D.)
Dust Caps
A
B
C (I.D.)
A
C (I.D.)
B
Figure Dimensions Features Plating Delta P/N
A B C Body Contact
1 .56 2.25 .144 Bead chain Nickel MX-913/U
1 .56 2.25 .144 Bead chain Silver M39012/25-0011
1 .56 3.75 .635 Safety chain Silver M39012/25-0012
1 .84 2.50 .170 Bead chain / shorting type Nickel Silver (C)1132-000-N00C-2
2 .72 3.50 .500 Bead chain Nickel 1133-000-N000
2 .91 2.50 .170 Bead chain / shorting type Nickel Silver (C)1133-000-N00C
Figure 1
(Shown with safety chain) Figure 2
(Shown with bead chain)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 26
N Accessories
(C) in contact plating column indicates captive contact.
Caps and terminations are available with other chain styles and/or resistances.
Bulkhead and Panel Mounted Jack–Jack Adapters
(Connect two plugs)
Figure Dimensions Max. Mounting Plating Delta P/N
AB
Panel Figure Body Contact
1 1.54 .863 .25 72 Nickel Silver (C)UG-30D/U
1 1.54 .863 .25 72 Nickel Silver (C)UG-30E/U
1 1.54 .863 .25 72 Silver Gold (C)M55339/04-00030
1 2.06 1.375 .75 72 Nickel Silver (C)1126-000-N728
2 1.75 1.00 . 33 Nickel Silver (C)1125-000-N330
.875 dia.
AB
A
B
Figure 1
(Bulkhead mount, hermetically sealed) Figure 2
(Panel mount)
Straight Adapters
Figure Dimensions Plating Delta P/N
A B Body Contact
1 1.75 .66 Nickel Silver (C)UG-29B/U
1 1.75 .66 Silver Gold (C)M55339/07-00029
2 1.59 .78 Nickel Silver (C)UG-57B/U
2 1.59 .78 Silver Gold (C)M55339/05-00057*
3 1.56 .78 Nickel Silver (C)1134-000-N000
A
B dia.
A
B dia.
A
B dia.
Figure 1
(Straight jack–jack;
connects two plugs)
Figure 2
(Straight plug–plug;
connects two jacks)
Figure 3
(Straight jack–plug;
connects one plug
and one jack)
* Lockwire holes in coupling nut.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 27
N Adapters
(C) in contact plating column indicates captive contact.
Right Angle Adapters
A
B
A
BB
.875 dia.
A
.92
Figure 1
(Right angle plug–jack;
connects one plug
and one jack)
Figure 2
(Right angle plug–plug;
connects two jacks)
Figure 3
(Bulkhead mounted right angle jack–jack;
connects two plugs)
Figure Dimensions Max. Mounting Plating Delta P/N
AB
Panel Figure Body Contact
1 1.30 1.38 .. Nickel Silver (C)UG-27C/U
1 1.38 1.30 .. Nickel Gold (C)UG-27D/U
1 1.38 1.30 .. Silver Gold (C)M55339/03-00027*
2 1.39 1.39 .. Nickel Silver (C)1137-000-N000
3 2.13 1.36 .25 72 Nickel Gold (C)UG-202A/U
* Lockwire holes in coupling nut.
Tee Adapters
Figure Dimensions Plating Delta P/N
A B Body Contact
1 1.75 1.22 Nickel Silver (C)UG-28A/U
1 1.75 1.22 Silver Gold (C)M55339/06-00028
2 1.75 1.47 Nickel Silver (C)UG-107B/U
2 1.75 1.47 Silver Gold (C)M55339/06-00001
3 2.03 1.22 Nickel Gold (C)1149-000-N001-1
A
B
A
B
A
B
Figure 1
(Tee jack–jack–jack;
connects three plugs)
Figure 2
(Tee jack–plug–jack;
connects two plugs and one jack)
Figure 3
(Tee jack–jack–plug;
connects two plugs and one jack)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 28
N Adapters
(C) in contact plating column indicates captive contact.
Straight Plug—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2B, 3B 1 1.80 .69 Nickel Silver UG-94A/U C/01
7 2 1.38 .50 Nickel Silver 1801-021-N000 A/02
Figure 1
A
B dia.
Figure 2
A
B dia.
Straight Jack—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2B, 3B 1 1.88 .69 Nickel Gold UG-95A/U C/08
7 2 1.41 .50 Nickel Silver 1808-021-N000 A/02
Figure 1
A
B dia.
Figure 2
A
B dia.
Bulkhead Jacks—for Flexible Cable
Cable Fig. Dimensions Mounting Max. Plating Delta P/N
Group ABC Figure Panel Body Contact
2B, 3B 1 1.84 .92 .69 72 .25 Nickel Gold 1816-003-N720 C/08
7 1 1.47 .92 .50 72 .25 Nickel Silver (C)1816-021-N721 A/14
2B, 3B 2 1.84 .92 .60 72 .25 Nickel Gold 1819-003-N720 B/03
7 2 1.59 .92 .50 72 .25 Nickel Silver 1819-020-N720 B/14
Figure 1
(Military clamp) Figure 2
(Crimp)
.875 dia.
AB
C dia.
AB.875 dia.
C
(crimp sleeve)
Assembly
Procedure/
Trim Code
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 29
N70 Cable Connectors
(C) in contact plating column indicates captive contact.
Panel Receptacle—Solder Pot Contact
Figure Dimensions Mounting Plating Delta P/N
ABCD Figure Body Contact
1 1.13 .66 .062 .080 33 Nickel Gold (C)1813-000-N331
2 1.10 .72 .062 .080 33 Nickel Silver (C)1823-000-N331-1
3 1.41 1.16 .30 .050 33 Nickel Gold (C)1815-000-N330
Figure 1
(Straight jack receptacle) Figure 2
(Straight plug receptacle)
AB
D
C (I.D.)
.083 dia.
C (I.D.)
.083 dia.
AB
D
Figure 3
(Right angle jack receptacle)
B
A
C
D (I.D.)
.083 dia.
Bulkhead Receptacle—Solder Pot Contact
Figure Dimensions Mounting Plating Delta P/N
ABCD Figure Body Contact
1 1.62 .707 .099 .250 72 Nickel Silver (C)1820-000-N728
Figure 1
(Front mount, hermetically sealed)
.812 dia. AB
C (I.D.)
D max. panel
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 30
N70 Receptacles
(C) in contact plating column indicates captive contact.
Straight Adapters
Figure Dimensions Plating Delta P/N
A B Body Contact
1 1.75 .66 Nickel Gold (C)1828-000-N000
2 1.59 .78 Nickel Gold (C)1827-000-N000
A
B dia.
A
B dia.
Figure 1
(Straight jack–jack;
connects two plugs)
Figure 2
(Straight plug–plug;
connects two jacks)
Right Angle and Tee Adapters
Figure Dimensions Plating Delta P/N
A B Body Contact
1 1.30 1.38 Nickel Gold (C)1829-000-N000
2 1.75 1.22 Nickel Gold (C)1838-000-N000
3 1.75 1.47 Nickel Gold (C)1830-000-N000
A
B
A
B
A
B
Figure 2
(Tee jack–jack–jack;
connects three plugs)
Figure 3
(Tee jack–plug–jack;
connects two plugs and one jack)
Figure 1
(Right angle jack–plug;
connects one plug and one jack)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 31
N70 Adapters
(C) in contact plating column indicates captive contact.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 32
Cable Groups
Delta Cable Groups
Group
Cables
1A RG-5, 5A, 5B, 21, 21A; M17/73, /162
1 1B RG-6, 6A; M17/2
1C RG-143, 143A, 212, 222; M17/73, /112, /162
22A RG-8, 8A, 213; M17/74
2B RG-11, 11A; M17/6
3A RG-9, 9A, 9B, 214; M17/75
3 3B RG-13A, 216; M17/77
3C RG-225; M17/127
4 RG-393; M17/127
5 RG-58, 58A, 58C, 141, 141A; M17/28, /111
66A RG-55A, 142, 142A, 223, 400; M17/60, /84, /128
6B RG-55, 55B, 142B; M17/60, /84
77A
RG-59, 59A, 59B, 62, 62A, 62B, 62C, 210; M17/29, /30, /97
7B RG-71, 71A, 71B; M17/90
88A RG-122; M17/54
8B RG-180, 180A, 180B, 195; M17/95, /137
99A RG-174, 188, 188A, 316; M17/152
9B RG-179A, 179B, 187, 187A; M17/94, /136
10 Double-Shielded RG-174, 316; M17/152
11 RG-178, 178A, 178B, 196, 196A; M17/93
12 .250" semi-rigid; RG-401; M17/129
13 .141" semi-rigid; RG-402; M17/130
14 .085" semi-rigid; RG-405; M17/133
15 RG-10, 12, 215; M17/6, /74
16 RG-14A, 217; M17/78, /165
17 RG-17A, 218
18 RG-18A, 219
19 RG-115A
20 RG-118A, 228A
21 RG-126
22 RG-302
23 RG-303
24 RG-304
25 Special 8X cable; contact factory for details.
26 Belden 8281
27 RG-108, 108A; M17/45
28 RG-22, 22A, 22B; M17/15
29 Belden 9207; Dearborn 6207; IBM 7362211
30 M17/176
31 AT&T 735A
RG-5, 5A, B 1A
RG-6, 6A 1B
RG-8, 8A 2A
RG-9, 9A, B 3A
RG-10 15
RG-11, 11A 2B
RG-12 15
RG-13A 3B
RG-14A 16
RG-17A 17
RG-18A 18
RG-21, 21A 1A
RG-22, 22A, B 28
RG-55, 55B 6B
RG-55A 6A
RG-58, 58A, C 5
RG-59, 59A, B 7A
RG-62, 62A, B, C 7A
RG-71, 71A, B 7B
RG-108, 108A 27
RG-115A 19
RG-118A 20
RG-122 8A
RG-126 21
RG-141, 141A 5
RG-142, 142A 6A
RG-142B 6B
RG-143, 143A 1C
RG-174 9A
RG-174DS 10
RG-178, 178A, B 11
RG-179A, 179B 9B
RG-180, 180A, B 8B
RG-187, 187A 9B
RG-188, 188A 9A
RG-195 8B
RG-196, 196A 11
RG-210 7A
RG-212 1C
RG-213 2A
RG-214 3A
RG-215 15
RG-217 16
RG-218 17
RG-219 18
RG-222 1C
RG-223 6A
RG-225 3C
RG-228A 20
RG-302 22
RG-303 23
RG-304 24
RG-316 9A
RG-316DS 10
RG-393 4
RG-400 6A
RG-401 12
RG-402 13
RG-405 14
M17/2 1B
M17/6 2B
M17/15 28
M17/28 5
M17/29 7A
M17/30 7A
M17/45 27
M17/73 1A
M17/162 1A
M17/112 1C
M17/74 2A
M17/75 3A
M17/127 3C
M17/77 3B
M17/60 6A
M18/84 6A
M17/128 6A
M17/97 7A
M17/54 8A
M17/95 8B
M17/137 8B
M17/152 9A
M17/93 11
M17/129 12
M17/130 13
M17/133 14
M17/78 16
M17/165 16
M17/176 30
AT&T 735A 31
Belden 8281 26
Belden 9207 29
Dearborn 6207 29
IBM 7362211 29
Cable Group Finder
Cable
Group
Cable
Group
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 33
Assembly Procedures
Assembly Procedure A
1) Trim cable jacket to dimension A.
Slide backnut, washer, V-gasket, and
braid clamp onto cable as shown.
Cable jacket should bottom on step
in braid clamp.
2) Comb braid wires out straight and fold back over front
shoulder of braid clamp (braid wires should not overlap
one another after folding). Trim braid wires flush with step
of braid clamp. Trim cable dielectric and center conductor
to dimensions B and C.
3) If support insulator is provided for RG-62 or 71 cable, insert
into hollow in dielectric. Assemble rear bushing or washer (if
supplied), rear insulator (if captive contact) and contact, and
solder contact to center conductor. Rear of contact should be
flush with cable dielectric end. For right angle connectors
with access cap, omit this step entirely.
4) Insert prepared cable and hardware into body
and tighten backnut. For right angle connectors
with access cap, solder center conductor into slot
in contact and tighten access cap.
Code A B C
A/01 .375 (3/8) .047 (3/64) .203 (13/64)
A/02 .375 (3/8) .109 (7/64) .203 (13/64)
A/03 .438 (7/16) .250 (1/4) .188 (3/16)
A/04 .281 (9/32) .047 (3/64) .125 (1/8)
A/05 .313 (5/16) .125 (1/8) .109 (7/64)
A/06 .594 (19/32) .391 (25/64) .156 (5/32)
A/07 .375 (3/8) .047 (3/64) .125 (1/8)
A/08 .281 (9/32) .109 (7/64) .094 (3/32)
A/09 .344 (11/32) .109 (7/64) .094 (3/32)
A/10 .406 (13/32) .109 (7/64) .203 (13/64)
A/11 .500 (1/2) .281 (9/32) .156 (5/32)
A/12 .343 .040 .219
A/13 .375 (3/8) .125 (1/8) .156 (5/32)
A/14 .355 .090 .188 (3/16)
A/15 .425 .094 (3/32) .259
A/16 .328 (21/64) .094 (3/32) .188 (3/16)
A/17 .375 (3/8) .109 (7/64) .125 (1/8)
A/18 .375 (3/8) .062 (1/16) .172 (11/64)
A/19 .375 (3/8) .188 (3/16) .094 (3/32)
Code A B C
A/20 .375 (3/8) .047 (3/64) .172 (11/64)
A/21 .500 (1/2) .313 (5/16) .172 (11/64)
A/22 .375 (3/8) .188 (3/16) .141 (9/64)
A/23 .438 (7/16) .078 (5/64) .172 (11/64)
A/24 .500 (1/2) .094 (3/32) .141 (9/64)
A/25 .438 (7/16) .141 (9/64) .172 (11/64)
A/26 .625 (5/8) .281 (9/32) .250 (1/4)
A/27 .688 (11/16) .281 (9/32) .125 (1/8)
A/28 .656 (21/32) .297 (19/64) .250 (1/4)
A/29 .688 (11/16) .125 (1/8) .313 (5/16)
A/30 .688 (11/16) .469 (15/32) .156 (5/32)
A/31 .700 (21/32) .453 (29/64) .250 (1/4)
A/32 .313 (5/16) .078 (5/64) .188 (3/16)
A/33 .250 (1/4) .078 (5/64) .094 (3/32)
A/34 .250 (1/4) .062 (1/16) .109 (7/64)
A/35 .837 .575 .150
A/36 .450 .250 .150
A/37 .281 .038 .188
A/38 .281 .069 .156
Trim Codes For Assembly Procedure A
Backnut Washer
(if supplied)
V-Gasket Braid Clamp
A
Washer and/or bushing
(if supplied)
Contact
(non-captive)
or
Contact (captive)
& insulator
Fold braid over
B
C
Non-captive Contact
Solder
Solder
Captive Contact
Washer or bushing (if supplied)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 34
Assembly Procedures
Assembly Procedure B
Crimp Sleeve Contact (captive)
Contact
(non-captive)
Solder
A
or
B C
1) Trim cable per chart. Slide crimp
sleeve back onto cable.
2) If support insulator is provided for RG-62 or 71
cable, insert into hollow in dielectric. Solder con-
tact onto center conductor; back of contact flush
with trimmed end of cable dielectric (omit this step
for right angle connectors with access caps). Flare
cut end of braid slightly by rotating dielectric.
3) Insert cable/contact into rear of body, with all braid wires on outside of crimp tail.
a) For captive contact connectors, push cable in until contact snaps into insulator.
b) For noncaptive contact connectors, push cable in until cable dielectric bottoms
in connector.
c) For right angle or tee connectors with access caps, push cable in until end of
braid touches connector body shoulder, and cable center conductor rests in
contact slot.
Trim excess braid wires even with shoulder of body. Slide crimp sleeve forward
until flush with body and crimp (see page 176 for hex die sizes).
For right angle or tee connectors with access caps: Solder center conductor into
contact slot, assemble insulator disc (if supplied), then press cap into body until
seated or screw into place.
Code A B C
B/01 .320 .470 .140
B/02 .422 .578 .172
B/03 .406 .500 .187
B/04 .285 .505 .140
B/05 .335 .460 .140
B/06 .187 .437 .219
B/07 .422 .610 .156
B/08 .422 .562 .219
B/09 .313 .610 .203
B/10 .280 .436 .187
B/11 .430 .542 .156
B/12 .300 .434 .156
B/13 .300 .447 .156
B/14 .420 .645 .187
B/15 .300 .420 .120
B/16 .312 .609 .125
B/17 .250 .500 .156
B/18 .437 .562 .109
B/19 .343 .437 .156
Code A B C
B/20 .250 .375 .156
B/21 .425 .550 .156
B/22 .375 .500 .156
B/23 .281 .469 .125
B/24 .250 .700 .109
B/25 .343 .775 .125
B/26 .343 .437 .109
B/27 .313 .437 .187
B/28 .219 .271 .078
B/29 .200 .320 .060
B/30 .500 .650 .219
B/31 .350 .840 .150
B/32 .175 .260 .095
B/33 .195 .270 .045
B/34 .150 .250 .105
B/35 .195 .280 .170
B/36 .150 .325 .090
B/37 .195 .295 .075
B/38 .150 .225 .095
B/39 .250 .300 .135
Trim Codes For Assembly Procedure B
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 35
Assembly Procedures
Assembly Procedure C
Backnut Washer
Gasket Braid Clamp
Contact (captive)
& insulator
Contact
(non-captive)
Fold braid over
Non-captive
Captive
Solder
A
B
C
or
1) Trim cable jacket to dimension A.
Slide backnut, washer, gasket, and
braid clamp onto cable as shown.
Cable jacket should bottom on step
in braid clamp.
2) Comb braid wires out straight and fold back over front
shoulder of braid clamp (braid wires should not overlap
one another after folding). Trim braid wires flush with
edge of braid clamp. Trim cable dielectric and center
conductor to dimensions B and C.
3) If support insulator is provided for RG-62 or 71 cable,
insert into hollow in dielectric. Assemble rear insulator
(if captive contact) and contact, and solder contact to
center conductor. Rear of contact should be flush with
cable dielectric end.
4) Insert prepared cable and
hardware into body and
tighten backnut. For right
angle connectors with access
cap, solder cable center
conductor to slot in contact
and tighten access cap.
Trim Codes
Code A B C
C/01 .656 (21/32) .141 (9/64) .250 (1/4)
C/02 .500 (1/2) .125 (1/8) .250 (1/4)
C/03 .450 .136 .187
C/04 .375 (3/8) .109 (7/64) .125 (1/8)
C/05 .375 (3/8) .062 (1/16) .250 (1/4)
C/06 .500 (1/2) .188 (3/16) .125 (1/8)
C/07 .575 .438 .094
C/08 .625 (5/8) .141 (9/64) .219 (7/32)
Assembly Procedure D
V-Gasket
Backnut Washer
Braid Clamp
Contact (captive)
& insulator
Contact
(non-captive)
Fold braid over
A
B
C
or
Armor Clamp
Non-captive
Captive
Solder
1) Slide armor clamp over cable. Push
armor back to expose cable end.
Slide backnut, washer (if supplied),
gasket, and braid clamp onto cable
as shown. Cable jacket should
bottom on step in braid clamp.
Trim cable jacket to dimension A.
2) Comb braid wires out straight and fold back over
front shoulder of braid clamp (braid wires should
not overlap one another after folding). Trim braid
wires flush with edge of braid clamp. Trim cable
dielectric and center conductor to dimensions B
and C.
3) Assemble rear insulator (if captive contact) and
contact, and solder contact to center conductor.
Rear of contact should be flush with cable
dielectric end.
4) Insert prepared cable and hardware into body and tighten backnut.
Trim armor to fit between armor clamp and braid clamp. Tighten armor clamp.
Trim Codes
Code A B C
D/01 .375 (3/8) .047 (3/64) .250 (1/4)
D/02 .500 (1/2) .188 (3/16) .219 (7/32)
D/03 .344 (11/32) .047 (3/64) .219 (7/32)
D/04 .313 (5/16) .047 (3/64) .172 (11/64)
D/05 .625 (5/8) .281 (9/32) .250 (1/4)
D/06 .313 (5/16) .062 (1/16) .109 (7/64)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 36
Assembly Procedures
Assembly Procedure E
Backnut
Contact/Insulator/
cone grip assembly
Solder
A
B
C
1) Slide backnut onto cable as
shown. Trim cable to dimen-
sions A and B as shown. Slit
jacket to dimension C in two
places, 180° apart.
2) Slide cone/insulator/contact assembly under
braid until braid is flush with shoulder.
Solder contact to center conductor.
3) Insert prepared cable and
hardware into body; tight-
en assembly by holding
nut stationary and turning
body.
Trim Codes
Code A B C
E/01 .250 (1/4) .141 (9/64) .313 (5/16)
E/02 .219 (7/32) .063 (1/16) .250 (1/4)
E/03 .250 (1/4) .031 (1/32) .250 (1/4)
Assembly Procedure F
Backnut Washer
V-Gasket Solder Ferrule
Contact (captive),
insulator, & bushing
Contact
(non-captive)
Non-captive
Captive
Solder
A
or
B
Solder
Solder
1) Trim cable per chart. Slide backnut,
washer, v-gasket, and solder ferrule
onto cable. Trimmed end of cable
jacket should bottom on step in
solder ferrule.
2) Solder ferrule to cable jacket as shown. Retrim
cable dielectric to proper length if it has
extruded from soldering heat. Slide bushing
and rear insulator over cable dielectric if captive
contact. Solder contact onto center conductor;
back of contact flush with trimmed end of
cable dielectric.
Trim Codes
Code A B
F/01 .250 (1/4) .219 (7/32)
F/02 .250 (1/4) .172 (11/64)
F/03 .188 (3/16) .188 (3/16)
F/04 .109 (7/64) .265 (17/64)
F/05 .156 (5/32) .250 (1/4)
F/06 .219 (7/32) .250 (1/4)
F/07 .156 (5/32) .172 (11/64)
F/08 .109 (7/64) .219 (7/32)
3) Insert prepared
cable and hard-
ware into body
and tighten
backnut.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 37
Assembly Procedures
Frame only—P/N M22520/5-01—Use with interchangeable dies listed below.
For Cable Group(s) Hex Die Size Die Set P/N Closure
2, 3, 4 .429 hex, .400 wide M22520/5-61 A
5, 6 .213 hex, .400 wide M22520/5-19 B
7 .255 hex, .400 wide M22520/5-19 A
9 .128 hex, .400 wide M22520/5-35 B
10 .151 hex, .400 wide M22520/5-37 B
11 .105 hex, .400 wide M22520/5-33 B
M22520/5-01
Crimp Tools for Flexible Cable
Assembly Procedure I
Cable end flush
with insulator
Body assembly Soft solder
all around
B
A
1) Trim cable as shown.
Remove any burrs
from jacket and
center conductor.
2) Insert cable into body and
solder cable jacket to body,
keeping end of cable flush
with insulator as shown.
Plug body assembly and contact shown; procedure is identical for jack connectors.
Trim Codes
Code A B
I/01 .090 70-90°
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 38
Mounting Figures
Connector Flanges
(Panel mounted connectors)
4-hole flanges
Figure AB C
04 1/2.360 .089
05 1/2.340 .102
07 11/16 .500 #3-56 tap
08 11/16 .500 .136
09 11/16 .500 .125
10 11/16 .500 .120
12 11/16 .500 .109
18 3/4.531 .136
26 1 .718 #6-32 tap
27 1 .718 #4-40 tap
30 1 .718 .166
32 1 .718 .136
32A 1 .718 .136*
33 1 .718 .125
34 13/32 .812 .150
36 13/16 .906 #6-32 tap
39 13/16 .906 .152
40 13/16 .906 .125
45 2 1.437 .257
91 .375 .250 .067
91A .375 .232 .093
A
square
C dia. typ.
B
(L) typ.
C
A
D
dia. typ.
B (L)
C
C
* Countersunk to .245 dia.
2-hole flanges
Figure ABCD
92 .223 .481 .625 .102
92A .260 .481 .625 .102
95 .640 1.015 1.30 .125
Panel Cutouts
(Bulkhead mounted connectors)
D-Hole
Figure A B
51 .755 .723
54 .630 .598
55 .630 .583
57 .557 .531
59 .505 .473
62 .442 .410
63 .407 .362
65 .380 .348
66 .319 .292
67 .255 .236
68 .195 .176
Double D-Hole
Figure A B
69 .755 .692
72 .630 .536
75 .380 .341
84 .319 .278
B
A dia.
B
A dia.
Round Hole
Figure A
82 .255
89 .380
A dia.
P.C. Board Drilling
Twinax connectors
Figure A B C D
PCB04 .045 .500 .250 .045
A dia. typ.
D
dia.
B (L) typ.
C
C (L) typ.
C
A dia. typ.
.0625 typ.
D
dia.
typ.
B (L) typ.
C
C (L) typ.
C
.125 (L)
C
Coaxial connectors
Figure ABCD
PCB01 .067 .400 .200 .045
PCB02 .045 .500 .250 .045
PCB03 .067 .300 .150 .035
PCB05 .067 .200 .100 .055
PCB06 .067 .200 .100 .045
PCB07 .045 .177 .088 .045
PCB08 .032 .100 .050 .032
(PCB traces are shown for illustrative purpose only,
and are not representative of actual circuitry.)
(PCB traces are shown for illustrative purpose only,
and are not representative of actual circuitry.)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 39
Warranty
We warrant our parts to be free from defects in materials and workmanship for one
year from date of purchase. During that time, we will repair or replace
(at our option) any parts found to be defective.
This warranty does not apply to parts which have been modified, used in
conditions exceeding Delta or military specifications, or disassembled. We will not,
under any circumstances, be responsible for consequential or incidental damages or
installation costs.
No other warranties apply, and no other liability may be assumed or extended by
representatives or distributors.
Returns
Returns will be accepted only with a Return Authorization number issued by Delta,
and are subject to inspection and acceptance upon arrival. Restocking charges will be
determined prior to issuance of Return Authorization.
All claims for shortages must be made within 30 days of receipt by customer.
Ordering Information
Orders are subject to the terms and conditions on our order acknowledgement,
which may only be modified by written agreement prior to sale. Order changes,
cancellation, or termination will be accepted only with written approval from Delta
Electronics Manufacturing.
Copyright, Trademarks, and Patents
Entire contents copyright 2003, Delta Electronics Manufacturing Corporation.
Reproduction rights are hereby granted for, and specifically limited to,
printing or other reproduction of drawings and specifications for inclusion in
specification or source control drawings, or for purchasing procedures, by Delta
customers only.
Heli-Grip, PressMount, and the New England Craftsmanship logo are
trademarks. The Heli-Grip design is covered by U.S. and foreign patents.
Delta Electronics Manufacturing Corporation
416 Cabot Street, P.O. Box 53
Beverly, MA 01915
FSCM/CAGE 00795 Catalog # Npdf 1.2 (7/09)
Ordering and Warranty Information