1N5820 - 1N5822
Document number: DS23003 Rev. 9 - 2 1 of 3
www.diodes.com November 2010
© Diodes Incorporated
1N5820 - 1N5822
3.0A SCHOTTKY BARRIER RECTIFIERS
Features and Benefits
Guard Ring Die Construction for Transient Protect ion
Low Power Loss, High Efficiency
High Surge Capability
High Current Capability and Low Forward Voltage Drop
For Use in Low Voltage, High Frequency Inverters, Free
Wheeling, and Polarity Protection Application
Lead Free Finish, RoHS Compliant (Note 1)
Mechanical Data
Case: DO-201AD
Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminals: Finish - Tin. Plated Leads Solderable per MIL-STD-
202, Method 208
Polarity: Cathode Band
Marking: Type Number
Weight: 1.1 grams (approximate)
Ordering Information (Note 2)
Device Packaging Shipping
1N5820-B DO-201AD 500 Bulk
1N5820-T DO-201AD 1.2K/Tape & Reel, 13-inch
1N5821-B DO-201AD 500 Bulk
1N5821-T DO-201AD 1.2K/Tape & Reel, 13-inch
1N5822-B DO-201AD 500 Bulk
1N5822-T DO-201AD 1.2K/Tape & Reel, 13-inch
Maximum Ratings @TA = 25°C unless otherwise specified
Characteristic Symbol 1N5820 1N5821 1N5822 Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage (Note 3)
VRRM
VRWM
VR 20 30 40 V
RMS Reverse Voltage VR
(
RMS
)
14 21 28 V
Average Rectified Output Current
(Note 4) @ TL = 95°C IO 3.0 A
Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load
@ TL = 75°C IFSM 80 A
Thermal Characteristics
Characteristic Symbol Value Unit
Typical Thermal Resistance (Note 5) R
θ
JA 40 °C/W
R
θ
JL 10
Operating and Storage Temperature Range TJ, TSTG -65 to +150 °C
Electrical Characteristics @TA = 25°C unless otherwise specified
Characteristic Symbol 1N5820 1N5821 1N5822 Unit
Forward Voltage @ IF = 3.0A
@ IF = 9.4A VFM 0.475
0.850 0.500
0.900 0.525
0.950 V
Peak Reverse Current @ TA = 25°C
at Rated DC Blocking Voltage (Note 3) @ TA = 100°C IRM 2.0
20 mA
Notes: 1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes.
2. For packaging details, go to our website at http://www.diodes.com.
3. Short duration pulse test used to minimize self-heating effect.
4. Measured at ambient temperature at a distance of 9.5mm from the case
5. Thermal resistance from junction to lead vertical P.C.B. mounted, 0.500" (12.7mm) lead length with 2.5 x 2.5" (63.5 x 63.5mm) copper pad.
1N5820 - 1N5822
Document number: DS23003 Rev. 9 - 2 2 of 3
www.diodes.com November 2010
© Diodes Incorporated
1N5820 - 1N5822
I AVERAGE OUTPUT CURRENT (A)
(AV),
0
1
2
3
4
10 50 90 150
T , LEAD TEMPERA TURE (ºC)
Fig. 1 Forward Current Derating Curve
L
Single Phase Half-Wave
60 Hz Resistive or Inductive
Load 9.5mm Lead Length
30 70 110 130
0.1
1.0
10
30
0.1 0.3 0.5 0.7 0.9 1.1
I, I
N
S
T
A
N
T
A
N
E
O
U
S
F
O
R
WA
R
D
C
U
R
R
E
N
T
(A)
F
V , INSTANT ANEOUS FORWARD VOLTAGE (V)
Fig. 2 Typical For w ar d Vol t age Char acte r istics
F
0
20
40
60
80
100
110 100
I,
P
EAK
F
O
R
WA
R
D S
U
R
G
E
C
U
R
R
E
N
T
(A )
FSM
NUMBER OF CYCLES AT 60 Hz
Fig. 3 Peak Forward Surge Current
10
100
1,000
0.1 1.0 10 100
C
,
T
O
T
AL
C
A
P
A
C
I
T
A
N
C
E (p
F
)
T
V , DC REVERSE VOL TAGE (V)
Fig . 4 Typical Tota l C apacita nce
R
T = 25ºC
j
f = 1MHz
V = 50m Vp-p
sig
Package Outline Dimensions
DO-201AD
Dim Min Max
A 25.40
B 7.20 9.50
C 1.20 1.30
D 4.80 5.30
All Dimensions in mm
1N5820 - 1N5822
Document number: DS23003 Rev. 9 - 2 3 of 3
www.diodes.com November 2010
© Diodes Incorporated
1N5820 - 1N5822
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated p roducts for any unintended or una uthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign p atents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their pro ducts and an y
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2010, Diodes Incorporated
www.diodes.com