INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R14
PS2401
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Min Max Units
Blocking Voltage - 500 VP
Reverse Input Voltage - 5 V
Input Control Current - 100 mA
Peak (10ms) - 1 A
Input Power Dissipation 1- 150 mW
Total Package Dissipation 2- 1600 mW
Isolation Voltage, Input to Output 3750 - Vrms
Operational Temperature -40 +85 ºC
Storage Temperature -40 +125 ºC
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 16.6 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
AC Operating Voltage IF=5mA VOP 20 - 240 Vrms
Load Current (Continuous) VL=120-240VAC IL0.005 - 1 Arms
Maximum Surge Current t<16ms IPEAK - - 20 A
Off-State Leakage Current VL=500VDC ILEAK --1mA
On-State Voltage Drop IL=1Arms - - - 1.2 Vrms
Critical Rate of Rise - dV/dt 1000 1200 - V/µs
Switching Speeds
Turn-On IF=5mA ton - - 0.5 Cycles
Turn-Off toff - - 0.5
Zero-Cross Turn-On Voltage 11st half-cycle --25V
Subsequent half-cycle - - 1 V
Operating Frequency - - 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On 2- PF 0.25 - - -
Capacitance Input-To-Output - CI/O -3 -pF
Input Characteristics
Input Control Current
For Normal Environment - IF
--5
mA
For High Noise Environment - - - 10
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Input Dropout Voltage - - 0.8 - - V
Reverse Input Current VR=5V IR- - 10 µA
1 Zero Cross 1st half-cycle @ < 100Hz.
2 Snubber circuits may be required at low power factors.
Electrical Characteristics @ 25ºC