www.clare.com
2R02
CPC1394
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Peak Blocking Voltage 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1100 mW
Total Package Dissipation 2550 mW
Isolation Voltage, Input to Output 5000 Vrms
Operational Temperature -40 to +85 ºC
Storage Temperature -40 to +125 ºC
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 3.00 mW / ºC
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous - IL- - 120
mA
Peak t=10ms ILPK - - 400
On-Resistance 1IL=120mA RON -2635 Ω
Off-State Leakage Current VL=600VPILEAK -- 1 μA
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.85 5
ms
Turn-Off toff - 0.46 3
Output Capacitance IF=0mA, VL=50V, f=1MHz COUT -50 - pF
Input Characteristics
Input Control Current 2IL=120mA IF- 0.45 2
mA
Input Dropout Current - IF0.2 0.4 -
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 μA
Common Characteristics
Input to Output Capacitance - CI/O -3 - pF
1 Measurement taken within 1 second of on-time.
2 For temperatures >60ºC, a LED current of 4mA is recommended.