AQY27❍
602
13.-(1) Load current vs. turn on time character-
istics
LED current: 10 mA; Load voltage: 10 V (DC);
Ambient temperature: 25°C 77°F
13.-(2) Load current vs. turn on time character-
istics
LED current: 10 mA; Load voltage: 10 V (DC);
Ambient temperature: 25°C 77°F
14.-(1) Load voltage vs . turn off time character-
istics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
5
4
3
2
1
00.5 1 1.5 2 2.5 30
AQY272
AQY275
Load current, A
Turn on time, ms
5
4
3
2
1
00 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
AQY277
AQY274
Load current, A
Turn off time, ms
0.5
0.4
0.3
0.2
0.1
00102030405060708090100
AQY272
AQY275
Load voltage, V
Turn off time, ms
14.-(2) Load voltage vs . turn off time character-
istics
LED current: 10 mA; Continuous load current:
100 mA; Ambient temperature: 25°C 77°F
15.-(1) Load current vs. turn off time character-
istics
LED current: 10 mA; Load voltage 10 V (DC);
Ambient temperature: 25°C 77°F
15.-(2) Load current vs. turn off time character-
istics
LED current: 10 mA; Load voltage 10 V (DC);
Ambient temperature: 25°C 77°F
0.5
0.4
0.3
0.2
0.1
00 50 100 150 200 250 300 350 400
AQY277
AQY274
Load voltage, V
Turn off time, ms
0.5
0.4
0.3
0.2
0.1
00 0.5 1.0 1.5 2.0 2.5 3.0
AQY272
AQY275
Load current, A
Turn off time, ms
0.5
0.4
0.3
0.2
0.1
00 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
AQY277
AQY274
Load current, A
Turn off time, ms
16. Maximum operating frequency vs . load v olt-
age/current characteristics
LED current: 10 mA;
Ambient temperature: 25°C 77°F
17. Applied voltage vs. output capacitance
characteristics
Frequency: 1 MHz;
Ambient temperature: 25°C 77°F
10
9
8
7
6
5
4
3
2
1
00 25 50 75 100 125 150 175 200
Duty factor=50%
Load voltage, V×load current, A
Maximum operating frequency, time/s
2000
1800
1600
1400
1200
1000
800
600
400
200
00 20 40 60 80 100
AQY272
AQY274
Applied voltage, V
Output capacitance, pF
AQY275AQY277
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog