SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
SAFETY STANDARDS Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
500ms, 80ms at full load 230VAC /115VAC
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
336.5K hrs min. MIL-HDBK-217F (25 )℃
171*61.5*36.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
0.73Kg; 20pcs/15.6Kg/0.9CUFT
Protection type : Shut down o/p voltage, re-power on to recover
40W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
■ Features :
HLG-40H series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
SELV
IP65 IP67
Blank : IP67 rated. Cable for I/O connection.
FMM
110
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
CONSTANT CURRENT REGION Note.4
HLG-40H-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance
18 ~ 24V15 ~ 21V 23 ~ 30V 28 ~ 35V 35 ~ 43V 41 ~ 49V 48 ~ 58V 59 ~ 68V
54 ~ 65V
86.5% 86.5% 88% 88% 88.5% 88.5% 89.5%88.5% 89.5%
±2.5%
2 ~ 3.33A
±2.0%
1.6 ~ 2.67A
±1.0%
1.2 ~ 2A
±1.0%
1 ~ 1.67A
±1.0%
0.8 ~ 1.34A
±1.0%
0.67 ~ 1.12A
±1.0%
0.5 ~ 0.84A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0%
0.45 ~ 0.75A
±0.5%
±0.5%
±1.0%
0.58 ~ 0.96A
±0.5%
±0.5%
12V
HLG-40H-12 HLG-40H-15 HLG-40H-20 HLG-40H-24 HLG-40H-30 HLG-40H-36 HLG-40H-42 HLG-40H-48 HLG-40H-54
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.84A
39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
200mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
300mVp-p
44 ~ 53V10.8 ~ 13.5V
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
42V
25.2 ~ 42V
0.96A
40.32W
200mVp-p
40 ~ 46V
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
EMC EMISSION
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP65 or IP67 approved ;
optional models for J61347-1, J61347-2-13 ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
COLD START 50A(t =210 s measured at 50% I ) at 230VAC
width peak
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
μ
( for 48V,54V only) ( except for 48V,54V ) ( Optional )
TOTAL HARMONIC DISTORTION
Bauar
Sicherheit
egel gema
tgepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
D (optional) : IP67 rated. Timer dimming function, contact MEAN WELL for details.