Isolated and Regulated 20 WATT Modular DC/DC Converters FED20W series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
INPUT SPECIFICATIONS
I/P Voltage Range (24/48V Nom.) 9-36 / 18-75VDC
Voltage Surge (100mS max) 24 V: 50 VDC; 48 V: 100 VDC
Under Voltage Lockout
24 VDC I/P DC/DC ON: 9 VDC OFF: 7.5 VDC
48 VDC I/P DC/DC ON: 15 VDC OFF: 18 VDC
Input Filter Pi Type
Input Voltage Variation (dv/dt) 5V/rms, max. to ETS300 132 part 4.4
Input Reflected Ripple Current 20mA p-p
Start Up Time (Power Up or RC) 20mS, typ.
On/Off Control Positive Logic: (Ref to - Input) is standard.
ON = Open or 3V < Vr < 12V
OFF = Short or 0V < Vr < 1.2V
Negative Logic: (optional)
ON = Short or 0V < Vr < 1.2V
OFF = Open or 3V < Vr < 12V
Efficiency See Selection Chart
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Load Regulation NL-FL Singles: ±0.5%
Duals: ±1%
Cross Regulation (Dual 25%-FL) ±5%
Voltage Adjustability (Single O/P) ±10%
Line Regulation (Single/Dual) ±0.2% / ±0.5%
Temperature Coefficient ±0.02%/°C, max.
Ripple/Noise See Selection Chart
Voltage Accuracy ± 1%
Transient Response Recovery
25% Load Step Change 250 microSeconds
Short Circuit Protection Continuous Hiccup, self-recovering
Overvoltage Protection, Zener Diode Clamp:
3.3V Output 3.9Volts
5V Output 6.2Volts
12V Output 15Volts
15V Output 18Volts
Overload Protection 150% of FL Rating, typ.
GENERAL SPECIFICATIONS
Input-Out Isolation 1600VDC
In/Out Capacitance 1500 pF, max.
Isolation Resistance 10000 M Ohms
Switching Frequency 400Khz, typ
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -40 to +105°C (see derate curve)
Relative Humidity 5-95%
Storage Temperature -55 to +125°C *
Maximum Case Temp 105°C *
Thermal Impedance Convection: 12°C/Watt
Convection w. Heatsink: 10°C/Watt
Thermal Shock MIL-STD-810D
Vibration 10-55Hz 10G 30 min. on X, Y, Z axes
MTBF
BELLCORE TR-NWT-000322 Case 1: 50% Stress, Temp. @ 40°C
1.691 MHrs
MIL-HDBK-217F TA=25°C FL, Ground Benign, Controlled Environment
562.9 KHrs
EMI EN55022A
ESD EN61000-4-2 Criteria B
Radiated Immunity EN61000-4-3 Criteria A
EFT EN61000-4-4B Criteria B
Surge EN61000-4-5B Criteria B
Conducted Immunity EN61000-4-6A Criteria A
PHYSICAL SPECIFICATIONS
Case Material Nickel-Coated Copper w. FR4 Base
Construction Encapsulated w, UL94-V0 Epoxy
Dimensions 2”L x 1”W x 0.4”H
(50.8 x 25.4 x 10.2mm)
Weight 0.95oz (27g)
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.