Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) A165S/W CSM_A165S_W_DS_E_4_1 Separate Construction with Cylindrical 16-dia. Body * Same separate construction as the A16-series Pushbuttons with Miniature Design of 28.5 mm * The same contacts can be used for both standard loads and microloads. * Oil-resistant IP65 models * Conforms to EN60947-5-1. Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions on page 15. List of Models Model Rectangular Solder terminals Voltagereduction lighting Screwless clamp connector Square Round A165@-J Series A165@-A Series A165@-T Series A165@-J Series A165@-A Series A165@-T Series A165@-J Series A165@-A Series A165@-T Series 1 A165S/W Model Number Structure Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Selector, Lamp (lighted models only), and Switch. For information on combinations, refer to Ordering Information on page 3. (1) (2) (3) (4) (5) (6) A165W - A 2A R - 24D - 1 (6) Contact Configuration Symbol 1 2 1P 2P 2S (1) Lighted/ Non-lighted Symbol S W Type Nonlighted Lighted (2) Shape of Selector Symbol J A T Shape Rectangular Square Round (3) Number of Notches/ Resetting Method Symbol No. of notches 2M 2 notches 2A No symbol Automatic R G Y Solder terminal PCB terminal Screw-less Clamp Color Black (non-lighted models only) Red Green Yellow (5) Light Source Symbol No symbol 24D Type Non-lighted 24-V LED Manual 3M 3 notches 3A Symbol Terminal Note: 1. Only DPDT contacts are available with 3-notch models and Screw-less Clamp models. 2. PCB terminals are available only with 2-notch models. (4) Color of Selector Reset method Manual Type SPDT DPDT SPDT DPDT DPDT Voltage Reduction Unit (24-V Built-in LED) Automatic Symbol Type T1 LED T2 Operating voltage 100/110 VAC/VDC 200/220 VAC/VDC Rated voltage 110 VAC/VDC 220 VAC/VDC Note: 1. Solder terminals are only available with 100-V models. 2. The Voltage Reduction Unit is not available for models with PCB terminals. 3. "T2" is available only for the Screw-less Clamp type. 2 A165S/W Ordering Information Ordering as a Set .................The model numbers used to order sets of Units are given in the following tables. One set comprises the Selector, Lamp (lighted models only), and Switch. Solder Terminals Rectangular A165@-J Oil-resistant IP65 No. of notches Output Reset method Manual SPDT Automatic 2 notches Manual DPDT Automatic 3 notches DPDT Manual Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-J2M@-24D-1 A165S-J2M-1 A165W-J2A@-24D-1 A165S-J2A-1 A165W-J2M@-24D-2 A165S-J2M-2 A165W-J2A@-24D-2 A165S-J2A-2 A165W-J3M@-24D-2 A165S-J3M-2 Note: Enter the desired color symbol for the Selector in @: R (red); Y (yellow); G (green). The Selector for non-lighted models is black. Square A165@-A Oil-resistant IP65 No. of notches Output Reset method Manual SPDT Automatic 2 notches Manual DPDT Automatic 3 notches DPDT Manual Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-A2M@-24D-1 A165S-A2M-1 A165W-A2A@-24D-1 A165S-A2A-1 A165W-A2M@-24D-2 A165S-A2M-2 A165W-A2A@-24D-2 A165S-A2A-2 A165W-A3M@-24D-2 A165S-A3M-2 Note: Enter the desired color symbol for the Selector in @: R (red); Y (yellow); G (green). The Selector for non-lighted models is black. Round A165@-T Oil-resistant IP65 No. of notches Output Reset method Manual SPDT Automatic 2 notches Manual DPDT Automatic 3 notches DPDT Manual Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-T2M@-24D-1 A165S-T2M-1 A165W-T2A@-24D-1 A165S-T2A-1 A165W-T2M@-24D-2 A165S-T2M-2 A165W-T2A@-24D-2 A165S-T2A-2 A165W-T3M@-24D-2 A165S-T3M-2 Note: Enter the desired color symbol for the Selector in @: R (red); Y (yellow); G (green). The Selector for non-lighted models is black. 3 A165S/W Ordering Information Ordering Individually ......... Selectors, Lamps, and Switches (Sockets) can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Selector (Listed on Page 5.) Rectangular Models Square Models Lighted Models Round Models Non-lighted Models Lamp LED only Note: Temperature rises in incandescent lamps can cause heat deformation. Switch (Listed on Page 7.) Solder terminals (no transformer) Lighted/non-lighted PCB terminals Lighted/non-lighted Note: Socket Unit Sets that combine a Lamp and a Socket Unit are also available. 4 A165S/W Ordering Information Ordering Individually .........Selectors, Lamps, and Switches (Sockets) can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Selectors (Oil-resistant IP65 Models Only) Appearance Number of notches Rectangular (A165@-J) Reset method Manual 2 notches Automatic Manual 3 notches Square (A165@-A) Fully automatic Manual 2 notches Automatic Manual 3 notches Round (A165@-T) Fully automatic Manual 2 notches Automatic Manual 3 notches Fully automatic Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-J2M@ A165S-J2M A165W-J2A@ A165S-J2A A165W-J3M@ A165S-J3M A165W-J3A@ A165S-J3A A165W-A2M@ A165S-A2M A165W-A2A@ A165S-A2A A165W-A3M@ A165S-A3M A165W-A3A@ A165S-A3A A165W-T2M@ A165S-T2M A165W-T2A@ A165S-T2A A165W-T3M@ A165S-T3M A165W-T3A@ A165S-T3A Selector color symbol Enter the desired color symbol for the Selector in @. R (red), Y (yellow), G (green) Enter the desired color symbol for the Selector in @. R (red), Y (yellow), G (green) Enter the desired color symbol for the Selector in @. R (red), Y (yellow), G (green) Note: The selector for non-lighted models is black. 5 A165S/W Ordering Information Sets .............................................. Select an Operation Unit and a Socket Unit Set (Lamp and Socket Unit). Operation Unit Set with Knob-type Selector Switch Rectangular Models Square Models Round Models Lighted Models Lighted/Non-lighted Models Socket Unit Set with Voltage-reduction Lighting Socket Unit Set with Screw-less Clamp Connectors Lamp Voltagereduction Lighting Lamp Lighted/ Non-lighted Models Note: The LED has a 24-VAC/VDC circuit built in. Note: Non-lighted models do not include a Lamp. Socket Unit Set (Sets include a Socket Unit and a Lamp.) Appearance Number of notches Classification 2 notches SPDT DPDT 3 notches DPDT 24 V Solder terminals Model A16W-2N@-24D-1 A16W-2N@-24D-2 A16W-3N@-24D-2 Socket Unit Set with Voltage Reduction Unit (Solder Terminal) Appearance Classification 2 notches Standard loads and microloads 2 notches 3 notches Operating voltage SPDT A16L-@-T1-1 100/110 VAC/VDC DPDT Model A16L-@-T1-2 A16W-3N@-T1-2 Note: The LED has a 24-VAC/VDC circuit built in. Insert one of the following letters into the box (@). Symbol R Y G Light color Red Yellow Green 6 A165S/W Ordering Information Screw-less Clamp Connector Socket Unit Set Appearance Classification Non-lighted No voltage-reduction lighting Lighted 100/110 VAC/VDC Voltage-reduction lighting 200/220 VAC/VDC Non-lighted No voltage-reduction lighting Lighted 100/110 VAC/VDC Voltage-reduction lighting 200/220 VAC/VDC 2 notches DPDT Standard loads and microloads 3 notches DPDT Note: The 100-V models and 200-V models have a 24-VAC/VDC circuit built in. Ordering Individually Insert symbols in and @. Symbol Light color R Red Y Yellow G Green Model A16-2S A16L--@-2S A16L--T1-2S A16L--T2-2S A16S-3N-2LS A16W-3N-@-2S A16W-3N--T1-2S A16W-3N--T2-2S Remarks Used for Pushbutton Switches and Knob-type Selector Switches. @ Symbol 5D 12D 24D Type Operating voltage 5 VDC 12 VAC/VDC 24 VAC/VDC LED Switches Appearance Classification SPDT DPDT DPDT SPDT DPDT DPDT SPDT DPDT SPDT DPDT 2 notches Lighted 3 notches Socket (without voltage-reduction lighting) Non-lighted 2 notches 3 notches Lighted 2 notches Non-lighted Model A16S-2N-1L A16S-2N-2L A16S-3N-2L A16S-2N-1 A16S-2N-2 A16S-3N-2 A16S-2N-1LP A16S-2N-2LP A16S-2N-1P A16S-2N-2P Solder terminal PCB terminal Lamps Operating voltage Super-bright 5 VDC Light color Red Yellow Green 12 VAC/VDC A16-5DSR A16-5DSY A16-5DSG A16-12DSR A16-12DSY A16-12DSG 24 VAC/VDC A16-24DSR A16-24DSY A16-24DSG Accessories and Tools (Order Separately) Accessories Name Appearance Panel Plugs Classification Rectangular Model A16ZJ-3003 Square A16ZA-3003 Round A16ZT-3003 Remarks Used for covering the panel cutouts for future panel expansion. Degree of protection: IP40 Tools Name Appearance Model Pushbutton Switch Applicable types Knob-type Key-type Emergency Selector Switch Selector Switch Stop Switch Remarks Indicator Screw Fitting A16Z-3004 Yes Yes Yes Yes Yes Convenient for ganged installation. Tighten to a torque of 0.39 N*m min. Extractor A16Z-5080 Yes Yes Yes Yes Yes Convenient for extracting the Switches and Lamps. Ordering as a Set: Refer to page 3. Specifications and dimensions: Refer to pages 8 to 10. Accessories, replacements, and tools: Refer to this page 7 A165S/W Specifications Approved Standard Ratings UL, cUL (File No. E41515) TUV (EN60947-5-1) (Low Voltage Directive) CCC (GB14048.5) 5 A at 125 VAC, 3 A at 250 VAC (general use) 3 A at 30 VDC (resistive) 3 A at 250 VAC 3 A at 30 VDC 5 A at 125 VAC 3 A at 250 VAC 3 A at 30 VDC Note: Certification has been obtained for the Socket Unit. For detailed information on individual products that have received certification, consult your supplier. Ratings Switch Ratings Contact Form Rated voltage 125 VAC 250 VAC 30 VDC Resistive load 5A 3A 3A Minimum applicable load: 1 mA at 5 VDC Rated values are obtained from tests conducted under the following conditions. 1. Load: Resistive load 2. Mounting conditions: No vibration and no shock 3. Temperature: 202C 4. Operating frequency: 20 times/min Name Contact form NC SPDT COM NO Super-bright LED Rated voltage Rated current 5 VDC Operating voltage 5 VDC5% 12 VAC/VDC 8 mA 12 VAC/VDC5% 24 VAC/VDC 24 VAC/VDC5% Internal limiting resistor Red, yellow: 300 Green: 160 Red, yellow: 1 k Green: 910 2.4 k Characteristics Socket Unit Item Screw-less Clamp Type Knob-type Selector Switch Allowable Mechanical operating frequency Electrical 20 operations/minute max. Insulation resistance 100 M min. (at 500 VDC) Between terminals of same polarity Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Between terminals of different 2,000 VAC, 50/60 Hz for 1 min polarity Between each terminal and ground 2,000 VAC, 50/60 Hz for 1 min Between lamp terminals 1,000 VAC, 50/60 Hz for 1 min* Vibration Malfunction resistance Destruction Shock resistance Malfunction Durability 10 operations/minute max. Type Recommended wire size Usable wires and tensile strength Twisted wire Solid wire Tensile strength 2 500 m/s 150 m/s2 max. (malfunction within 1 ms) 250,000 operations min. Electrical 100,000 operations min. Screw-less Clamp 2 0.5 mm twisted wire or 0.8 mm-dia. solid wire 0.3 mm2 0.5 mm2 Compliant standards 0.75 mm2 1.25 mm2 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. 10 N 20 N Length of exposed wire 30 N --40 N 10 1 mm JIS C 2811 Terminal Blocks for Industrial Use Operating Characteristics 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) Mechanical Electric shock protection class Item Type Characteristics Knob-type Selector Switch 2 notches Operating force (OF) max. Set position (SP) 3 notches 0.1 N*m 905 45 +100 Class II PTI (tracking characteristic) 175 Degree of contamination 3 (IEC60947-5-1) Weight Approx. 13 g (in the case of a lighted DPDT switch) Ambient operating temperature -10C to 55C (with no icing or condensation) Ambient operating humidity 35% to 85%RH Ambient storage temperature -25C to 65C (with no icing or condensation) * With LED not mounted. (Perform testing with the LED not mounted.) 8 A165S/W Specifications Operation Angle Contact Form Two notches Three notches (75) (45) 45 90 FP FP (45) 45 Contact from No. of SPDT DPDT notches PosiPosiSW SW2 SW1 tion tion 2 notches Note: The angle used for automatic reset is shown in parentheses. FP: Free Position 3 notches --SW2 SW1 Nomenclature Model structure Selector Flange Shape Rectangular (A165@-J) Color of Selector * LED models Red Yellow Green * Non-lighted models Black Lighting Method * Lighted (LED) models (The upper face of the knob is illuminated.) * Non-lighted models Square (A165@-A) Round (A165@-T) Number of Notches and Reset Method * 2 Notches: Manual reset, Automatic reset * 3 Notches: Manual reset, Automatic reset Protective Structure Oil-resistant IP65 Switch Switch Specifications 5 A at 125 VAC 5 A at 250 VAC 3 A at 30 VDC Minimum applicable load: 1 mA at 5 VDC Terminal Type Solder terminals PCB terminals The flange can be rotated to easily change the operation angle of the knob. For information on rotating the flange, refer to page 14. Example: Knob-type Selector Switch with Two Notches FP (75) 90 90 90 (Standard condition when shipped) Note: The angle is 75 for self-resetting models. 9 A165S/W Dimensions * The Dimension shows 2-switch outputs. (Unit: mm) * The lamp terminal is not provided with non-lighted models. Rectangular A165@-J Solder terminals (tab terminals #110) M16x1 12.2 4 18 Lamp terminal 10.8 9.5 21.1 28.5 18.5 24 6 4.85 12.4 15.8 18 Model, standard, lot No., serial number Mounting nut Packing (t0.5) Note: See page 12 for panel cutouts. Lock ring M16x1 Square A165@-A Solder terminals (tab terminals #110) 12.2 4 18 Lamp terminal 10.8 9.5 18 6 21.1 28.5 18.5 4.85 12.4 15.8 18 Model, standard, lot No., serial number Mounting nut Packing (t0.5) Note: See page 12 for panel cutouts. Lock ring Round A165@-T Solder terminals (tab terminals #110) M16x1 12.2 4 18 Lamp terminal 10.8 9.5 18 6 18.5 21.1 28.5 4.85 12.4 15.8 18 Model, standard, lot No., serial number Note: See page 12 for panel cutouts. Packing (t0.5) Mounting nut Lock ring 10 A165S/W Dimensions * The Dimension shows 2-switch outputs. (Unit: mm) * A rectangular model is listed as an example. M16x1 Rectangular A165@-J PCB terminals 18.4 20.4 0.5 9.5 24 6 18.5 * The lamp terminal is not also provided with nonlighted models. 6.3 4 10.8 21.1 28.3 18 4.85 12.4 18.6 0.5 Mounting nut Note: See page 12 for panel cutouts. Rectangular A165W@-T Reduced-voltage lighting solder terminals (tab terminals #110) Packing (t0.5) Lock ring 50.1 42.7 18.5 9.5 28.5 21.1 10.8 Panel Cutouts 4 0.5 Direction-indication arrow 0.5 Selector 16 +0.2 0 dia. 24 min. 12.2 9.8 18 0.5 M16x1 23 min. Case Packing (t0.5) 6 Lock ring Mounting nut Switch (22.4) 20.6 18 8.8 16.6 2.8 12.4 2.8 24 Rectangular A165@-2S Screw-Less Clamp 18.5 9.5 48.9 Panel Cutouts 10.8 4 2 24 23.9 16 +0.2 0 dia. 25 min. M16x1 6 Switch dismounting lever Lock ring 33 min. Mounting nut * The lamp terminal is also provided with nonlighted models. (31.7) 27.4 18 24 23.5 Packing (t0.5) 11 A165S/W Dimensions (Unit: mm) Panel Cutouts Models with Solder Terminals and Models with Screw-less Clamp Connectors Rectangular A165@-J Square A165@-A, Round A165@-T (Top View) +0.2 16 0 (Top View) 16 24 min. (25 min.) dia. +0.2 0 dia. 19 min. (25 min.) 19 min. (33 min.) 19 min. (33 min.) Note: 1. Make sure the thickness of the mounting panel is 0.5 to 3.2 mm. 2. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. 3. Figures in parentheses are for screw-less clamp connectors. Models with PCB Terminals Rectangular A165@-J Square A165@-A, Round A165@-T (Top View) (Top View) 16 +0.2 0 dia. 24 min. 16 9.10.05 +0.2 0 dia. 24 min. 9.10.05 14.70.05 dia. 14.70.05 dia. 24 min. 5.10.05 24 min. 5.10.05 Note: 1. Ensure that the variation in the distance between the centers of neighboring mounting holes is less than 0.1 mm. 2. Make sure the thickness of the mounting panel is 0.5 to 3.2 mm. If, however, a Switch Guard or Dust Cover is used, the thickness of the mounting panel must be 0.5 to 2 mm. 3. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. Terminal Arrangement Models with Solder Terminals without Reduced-voltage Lighting (Lamp terminals are not provided with the Non-lighted Knob-type Selector Switches and Key-type Selector Switches.) Lighted SPDT Switches Lighted DPDT Switches Terminal Arrangement (Bottom View) Dimensions of Terminal Holes NC 2.6 0.9 Terminal Arrangement (Bottom View) Dimensions of Terminal Holes 2.6 0.9 COM 1.5 2.8 18 Note: The L+ is not shown on the Switch. 1.5 2.8 12.2 Lamp terminal Non-lighted SPDT Switches 18 COM SW1 SW2 Note: The L+ is not shown on the Switch. Terminal Arrangement (Bottom View) Side with TOP indicated Side with TOP indicated Dimensions of Terminal Holes Dimensions of Terminal Holes 1.5 2.8 NO COM Non-lighted DPDT Switches Terminal Arrangement (Bottom View) 2.6 0.9 NC L- NO 7.4 SW1 12.2 Lamp terminal NC L- NO 7.4 7.4 2.6 0.9 NC 12.2 18 NO COM SW1 1.5 2.8 7.4 NC 12.2 18 NC NO NO COM COM SW1 SW2 12 A165S/W Dimensions (Unit: mm) Models with PCB Terminals Lighted SPDT Switches Model, rating, and lot number indication Dimensions of PCB Terminals Lighted DPDT Switches Terminal Arrangement (Bottom View) Terminal Arrangement (Bottom View) Dimensions of PCB Terminals Side with TOP indicated Side with TOP indicated 5.3 5.3 3.5 NC 1.5 3.5 L- NC 1.5 NO COM 0.8 SW1 4.85 2.7 0.8 4.85 2.7 12.4 Lamp terminal (t=0.5) NC NO COM COM SW1 SW2 12.4 18.6 Lamp terminal (t=0.5) PCB Cutouts (Bottom View) 18.6 PCB Cutouts (Bottom View) Side with TOP indicated Side with TOP indicated A0.1 12.40.05 200.1 L- NO 12.40.05 200.1 4.850.05 L0.1 Five, 1 dia. 6.30.05 A0.1 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. 4.850.05 6.30.05 6.30.05 L0.1 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. Eight, 1 dia. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: For details of the terminal arrangement for Screw-Less Clamps, refer to the corresponding section for the A16. 13 A165S/W Dimensions (Unit: mm) Non-lighted Models with PCB Terminals (Lamp terminals are not provided with the Non-lighted Knob-type Selector Switches and Key-type Selector Switches.) Non-lighted SPDT Switches Dimensions of PCB Terminals Non-lighted DPDT Switches Terminal Arrangement (Bottom View) Model, rating, and lot number indication Side with TOP indicated 5.3 Terminal Arrangement (Bottom View) Dimensions of PCB Terminals Side with TOP indicated 5.3 NC NC 3.5 3.5 NO 1.5 1.5 COM SW1 0.8 12.4 2.7 0.8 NO COM COM SW1 SW2 12.4 2.7 18.6 18.6 PCB Cutouts (Bottom View) Side with TOP indicated NC NO PCB Cutouts (Bottom View) Side with TOP indicated A0.1 200.1 A0.1 200.1 12.40.05 12.40.05 L0.1 Three, 1 dia. 6.30.05 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. 6.30.05 6.30.05 L0.1 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. Six, 1 dia. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. For details on mounting the Switch to a panel, and mounting and dismounting the Switch, refer to installation details for the A16 Pushbutton Switch. Flange Rotation (All Selector Switches) A165 Knob-type Selector Switch A165 Key-type Selector Switch Fix the Switch screw and rotate the flange in 45 turns. Fix the Switch screw and rotate the flange in 45 turns. Flange Flange Lock ring Lock ring Switch screw Switch screw 14 A165S/W Safety Precautions Refer to Safety Precautions for All Pushbutton Switches. WARNING Always turn OFF the power and wait for 10 minutes before replacing the incandescent lamp. If the lamp is replaced immediately after the power is turned OFF, the remaining heat may cause burns. Precautions for Correct Use Mounting * Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. * Do not tighten the mounting nut more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting nut. The tightening torque is 0.29 to 0.49 N*m. Using the Microload * Insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. * The A16 allows both a standard load (125 V at 5A, 250 V at 3 A) and a microload. If a standard load is applied, however, the microload area cannot be used. If the microload area is used with a standard load, the contact surface will become rough, and the opening and closing of the contact for a microload may become unreliable. * The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% ( 60) (conforming to JIS C5003). The equation, 60 = 0.5 x 10-4/operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60%. Voltage (V) Do not apply a voltage between the incandescent lamp and the terminal that is greater than the rated voltage. If the incandescent lamp is broken, the operating part may pop out. Wiring * Solder terminals and quick-connect terminals (#110) are commonly used for terminals. * Be sure to use electrical wires that are a size appropriate for the applied voltage and carry current (conductor size is 0.5 to 0.75 mm2). Perform soldering according to the conditions provided below. If the soldering is not properly performed, the lead wires will become detached, resulting in short-circuits. 1. Hand soldering: 350C, within 3 s 2. Dip soldering: 350C, within 3 s Wait for one minute after soldering before exerting any external force on the solder. * Use non-corrosive resin fluid as the flux. * Make sure that the electric cord is wired so that it does not touch the Unit. If the electric cord touches the Unit, then electric wires with a heat resistance of 100C min. must be used. * After wiring the Switch, maintain an appropriate clearance and creepage distance. Operating Environment * The IP65 model is designed with a degree of protection so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. 0.15 mA 30 24 Microload area 12 Invalid area 5 1 mA 0 0.1 1 10 100 1,000 Current (mA) LED * The LED current-limiting resistor is built-in, so external resistance is not required. Rated voltage 5 VDC 12 VAC/VDC 24 VAC/VDC Internal limiting resistor Red, yellow: 300 Green: 160 Red, yellow: 1 k Green: 910 2.4 k 15 A165S/W Others * The oil-resistant IP65 uses NBR rubber and is resistant to general cutting oil and cooling oil. Some particular oils cannot be used with the oil-resistant IP65, however, so contact your OMRON representative for details. * If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after the coating. * Do not subject the Switch to extreme shock or vibration. Doing so will cause malfunctions and damage to the Switch. Do not let sharp objects come into contact with the Switches that are made of resin. Doing so will damage the Switches, causing scratches on the outside of the operating parts, and malfunction. When handling the Switches, do not throw or drop them. Do not allow the Switch to drop and hit the ground. Do not place or drop heavy objects on the Switch. Do not operate the Switch with hard or sharp objects. Hammer Screwdriver 16 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: A165W-T3MR-24D-2 A165S-T3A-2